TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality · TUV Rheinland (India) Pvt. Ltd. Product...

19
TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19631307.002 Bangalore, May 2017 Certificate No. T- 1543

Transcript of TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality · TUV Rheinland (India) Pvt. Ltd. Product...

Page 1: TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality · TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19631307.002

TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality

Test Report

Photovoltaic module Testing

TÜV Report No. 19631307.002

Bangalore, May 2017

Certificate No. T - 1543

Page 2: TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality · TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19631307.002
Page 3: TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality · TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19631307.002
Page 4: TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality · TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19631307.002

2 / 17

TUV Rheinland(India) Pvt.Ltd, Plot No.17B,Electronic city, Phase II,Begur Hobli,Bangalore(south)-560 100,India, Report.no:19631307 001

Tel: +91 80 3923430, Fax:+91 80 3055 4342 Mail: [email protected] Web: www.ind.tuv.com - CIN:U72501KA1996PTC020653

Contents

CONTENTS ........................................................................................................................................................ 2

ADDRESS/ES OF THE MANUFACTURING SITE/S: ............................................................................................... 3

SUMMARY OF TESTING: ................................................................................................................................... 3

SUMMARY OF TEST LOCATIONS: ...................................................................................................................... 3

SUMMARY OF DEVIATIONS FROM THE STANDARD: ......................................................................................... 3

GENERAL PRODUCT INFORMATION: ................................................................................................................ 4

TEST PROCEDURE: ............................................................................................................................................ 4

TABLE 1: MODULE GROUP ASSIGNMENT ......................................................................................................... 5

TABLE 2: CONSTRUCTIONAL CHARACTERISTICS ................................................................................................ 5

TABLE 3: MARKING REQUIREMENTS ................................................................................................................ 5

TABLE 4: VISUAL INSPECTION ........................................................................................................................... 6

TABLE 5: MAXIMUM POWER DETERMINATION AFTER PRECONDITIONING ...................................................... 6

TABLE 6: COMPARISON OF MEASURED POWER WITH NAME PLATE OF THE MODULE AFTER PRECONDITIONING .......................................................................................................................................... 6

TABLE 7: AVERAGING OF THREE TEST MODULES ............................................................................................. 7

TABLES 8: TEST MATRIX OF MODULE PERFORMANCE WITH RESPECT TO TEMPERATURE AND IRRADIANCE .. 10

TABLE 8.1: PMAX [W] VERSUS IRRADIANCE AND TEMPERATURE ....................................................................................... 10 TABLE 8.2: ISC [A] VERSUS IRRADIANCE AND TEMPERATURE ............................................................................................ 10 TABLE 8.3: VOC [V] VERSUS IRRADIANCE AND TEMPERATURE .......................................................................................... 10 TABLE 8.4: VMAX [V] VERSUS IRRADIANCE AND TEMPERATURE ......................................................................................... 11 TABLE 8.5: IMAX [A] VERSUS IRRADIANCE AND TEMPERATURE .......................................................................................... 11

TABLE 9: SUMMARY OF REFERENCE POWER CONDITIONS (AT AM 1,5) .......................................................... 11

TABLE 10: MAXIMUM POWER DETERMINATION AFTER MATRIX GENERATION ............................................. 12

TABLE 11: COMPARISON OF MEASURED POWER WITH NAME PLATE OF THE MODULE AFTER MATRIX GENERATION .................................................................................................................................................. 12

TABLE 12: MEASUREMENT OF TEMPERATURE COEFFICIENTS ......................................................................... 12

ANNEX 1: MEASUREMENT CURVE .................................................................................................................. 13

ANNEX 2: EQUIPMENT USED .......................................................................................................................... 15

ANNEX 3: STATEMENT OF THE ESTIMATED UNCERTAINTY OF THE TEST VERDICTS AND SPECTRUM AT TEST PLANE ............................................................................................................................................................ 15

ANNEX 4: PICTURES OF TEST SAMPLES ........................................................................................................... 16

ANNEX 5: SERIAL NUMBERS ........................................................................................................................... 17

Page 5: TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality · TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19631307.002

3 / 17

TUV Rheinland(India) Pvt.Ltd, Plot No.17B,Electronic city, Phase II,Begur Hobli,Bangalore(south)-560 100,India, Report.no:19631307 001

Tel: +91 80 3923430, Fax:+91 80 3055 4342 Mail: [email protected] Web: www.ind.tuv.com - CIN:U72501KA1996PTC020653

Address/es of the manufacturing site/s:

Name / Description: Waaree Energies Limited

Street: Plot No 231-236, Surat Special Economin zone

Postcode / City: Surat 394230

Country: India

Type of production: Solar Photovoltaic Modules

Inspection report no: NA

Summary of testing:

According to the inquiry of the customer, for testing as per IEC 61853-1, Photovoltaic (PV) module performance testing and energy rating – Part 1:Irradiance and temperature performance measurements and power rating on PV module type WS 320, the results are incorporated in this report no: 19631307.002. The above listed module type have passed all tests of the IEC 61215:2005 standard before testing as per IEC 61853-1. Pass criteria:

1. The values of STC power measured after preconditioning fall within the power range specified by the manufacturer of this product. (results enclosed)

2. After generating the matrix of parameters, the modules are remeasured at STC to verify that the performance is stable. (results enclosed)

All presented results are only valid for the exact tested module type and design (cell type, encapsulation

material, glass type)

Summary of test locations:

All tests were performed at TUV Rheinland (India) Pvt Ltd, Bangalore.

Summary of deviations from the standard:

- NA

Page 6: TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality · TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19631307.002

4 / 17

TUV Rheinland(India) Pvt.Ltd, Plot No.17B,Electronic city, Phase II,Begur Hobli,Bangalore(south)-560 100,India, Report.no:19631307 001

Tel: +91 80 3923430, Fax:+91 80 3055 4342 Mail: [email protected] Web: www.ind.tuv.com - CIN:U72501KA1996PTC020653

General product information:

PV module type reference ........................................................... : WS 320

Nominal maximum power (Pmax) .................................................. : 320 W 0/+ 5 W

Nominal open circuit voltage at (Voc) ........................................... : 45.30 V

Nominal short circuit current at (Isc) ............................................. : 9.42 A

Nominal maximum power voltage (Vmax) ..................................... : 36.80 V

Nominal maximum power current (Imax)....................................... : 8.70 A

Product Safety Ratings -

Maximum system voltage ............................................................ : 1000 V

Test procedure:

Random sampling from production

Prototype submitted by client

Test performed with a solar simulator. In order to minimize the errors related to translations/interpolations, we used the irradiance-specific temperature coefficients as per IEC 60891:2009, and the temperature and irradiance conditions during the tests were

maintained very close (within ±1 ⁰C and 10 W/m2) to the reporting conditions of 15, 25, NOCT, 50 and 75 ⁰C and

100, 200, 400, 500, 600, 800, 1000, and 1100 W/m2.

The linearity of the module and test setup meets the requirements as per IEC 60904-10

Description of similarity (differences) between the applied model and the previously tested model: NA

Page 7: TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality · TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19631307.002

5 / 17

TUV Rheinland(India) Pvt.Ltd, Plot No.17B,Electronic city, Phase II,Begur Hobli,Bangalore(south)-560 100,India, Report.no:19631307 001

Tel: +91 80 3923430, Fax:+91 80 3055 4342 Mail: [email protected] Web: www.ind.tuv.com - CIN:U72501KA1996PTC020653

Table 1: Module group assignment

Sample no. Client serial number

1803169930-05 WS04179003853068

1803169930-06 WS04179003853066

1803169930-07 WS04179003853062

1803169930-08 WS04179003853075

Table 2: Constructional characteristics

Components Model/Type Manufacturer

Junction Box PV-ZH011-3 ZHEJIANG ZHONGHUAN SUNTER PV TECHNOLOGY CO LTD.

JB Sealant AS-60 Manufactured by Sikasil

Frame Sealant AS-60 Manufactured by Sikasil

Frame Extruded anodized Aluminium frame (40 mm)

Jiangyin East China Corp. Ltd.

EVA (FRONT) 15580P (0.46 mm thick) SPECIALIZED TECHNOLOGY RESOURCES INC

EVA (BACK) 15580P (0.46 mm thick) SPECIALIZED TECHNOLOGY RESOURCES INC

Backsheet Dymat PYE Coveme

Glass Low iron tempered glass, AR coated, 4.0 mm thick glass

XYG

TCI - Luvata Malayasia

Bus bar - Luvata Malayasia

Flux X33-08i Henkel

Cell Multi crystalline-4bb Jupiter International Ltd.

Module parameters

Module dimensions (L x W x T) in mm

Cell technology Number of cells Number of bus bars Cell area in cm2

1958 x 990 x 40 Poly 72 4BB 243.36

Table 3: Marking requirements

Parameters Verdict

Name, monogram or symbol of the manufacturer P

Type or model number P

Serial number P

Polarity of terminals or leads (colour coding is permissible) P

Nominal and minimum values of maximum output power at STC after preconditioning, as specified by the manufacturer for the product type (see Clause 5).

P

The date and place of manufacture shall be marked on the module or be traceable from the serial number.

P

Supplementary information: None

Page 8: TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality · TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19631307.002

6 / 17

TUV Rheinland(India) Pvt.Ltd, Plot No.17B,Electronic city, Phase II,Begur Hobli,Bangalore(south)-560 100,India, Report.no:19631307 001

Tel: +91 80 3923430, Fax:+91 80 3055 4342 Mail: [email protected] Web: www.ind.tuv.com - CIN:U72501KA1996PTC020653

Table 4: Visual inspection

Test date [DD/MM/YYYY] 09-05-2017 —

Sample no. Nature and position of initial findings —

1803169930-05 No major visual defects found P

1803169930-06 No major visual defects found P

1803169930-07 No major visual defects found P

1803169930-08 No major visual defects found P

Supplementary information: Visual inspection performed as per IEC 61215 clause 7

Table 5: Maximum power determination after preconditioning

Test date [DD/MM/YYYY]: 09-05-2017 to 15-05-2017

Module temperature °C . Corrected to 25

Irradiance W/m²: ………. 1000

Sample no. Pmax W Vmax V Imax A Voc V Isc A FF % M.efficy in [%]

C.efficy in [%]

Rsh in ohms

Rs in ohms

1803169930-05 324.81 37.23 8.725 45.74 9.190 77.27 16.76 18.53 246.70 0.520

1803169930-06 321.57 37.05 8.679 45.59 9.177 76.86 16.59 18.35 171.98 0.522

1803169930-07 322.48 37.42 8.619 45.61 9.118 77.54 16.64 18.40 593.37 0.511

1803169930-08 320.46 37.48 8.551 45.59 9.078 77.43 16.53 18.29 579.96 0.529

Supplementary information: Preconditioning done as per IEC 61215 clause 5

Table 6: Comparison of measured power with name plate of the module after preconditioning

Test date [DD/MM/YYYY]: 09-05-2017 to 15-05-2017

Sample no. Power measured at STC after

preconditioning in [W] Power on name plate -

1803169930-05 324.81

320 W 0/+5W

P

1803169930-06 321.57 P

1803169930-07 322.48 P

1803169930-08 320.46 P

Supplementary information: None

Page 9: TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality · TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19631307.002

7 / 17

TUV Rheinland(India) Pvt.Ltd, Plot No.17B,Electronic city, Phase II,Begur Hobli,Bangalore(south)-560 100,India, Report.no:19631307 001

Tel: +91 80 3923430, Fax:+91 80 3055 4342 Mail: [email protected] Web: www.ind.tuv.com - CIN:U72501KA1996PTC020653

Table 7: Averaging of three test modules

Irrad [W/m

2]

Temp. [⁰C]

Sample no. Pmax [W]

Vmax [V]

Imax [A]

Voc [V]

Isc [A]

FF [%]

M.Eff [%]

C.Eff [%]

1100

75

1803169930-06 276.95 29.22 9.478 38.44 10.415 69.17 12.99 14.37

1803169930-07 279.75 29.74 9.407 38.48 10.385 70.00 13.12 14.51

1803169930-08 280.67 29.83 9.409 38.60 10.353 70.24 13.16 14.56

Average 279.12 29.60 9.431 38.51 10.384 69.80 13.09 14.48

50

1803169930-06 317.69 33.56 9.466 42.34 10.234 73.32 14.90 16.48

1803169930-07 319.38 33.64 9.494 42.34 10.206 73.91 14.98 16.57

1803169930-08 317.54 33.61 9.449 42.40 10.163 73.69 14.89 16.47

Average 318.20 33.60 9.470 42.36 10.201 73.64 14.92 16.51

25

1803169930-06 351.63 37.05 9.491 45.71 10.074 76.35 16.49 18.24

1803169930-07 353.13 37.51 9.413 45.79 9.999 77.13 16.56 18.32

1803169930-08 350.63 37.07 9.460 45.76 9.960 76.94 16.44 18.19

Average 351.80 37.21 9.455 45.75 10.011 76.81 16.50 18.25

1000

75

1803169930-06 257.07 30.00 8.568 38.41 9.491 70.52 13.26 14.67

1803169930-08 256.95 29.69 8.654 38.47 9.408 71.00 13.26 14.66

1803169930-07 258.60 30.07 8.598 38.53 9.432 71.15 13.34 14.76

Average 257.54 29.92 8.607 38.47 9.444 70.89 13.29 14.70

50

1803169930-06 291.79 34.03 8.575 42.19 9.335 74.10 15.05 16.65

1803169930-08 291.54 34.00 8.575 42.24 9.257 74.56 15.04 16.64

1803169930-07 292.89 33.99 8.616 42.21 9.282 74.76 15.11 16.71

Average 292.07 34.01 8.589 42.21 9.291 74.47 15.07 16.67

25

1803169930-06 321.57 37.05 8.679 45.59 9.177 76.86 16.59 18.35

1803169930-07 322.48 37.42 8.619 45.61 9.118 77.54 16.64 18.40

1803169930-08 320.46 37.48 8.551 45.59 9.078 77.43 16.53 18.29

Average 321.50 37.32 8.616 45.60 9.124 77.28 16.59 18.35

15

1803169930-06 330.75 38.82 8.520 46.91 9.049 77.92 17.06 18.87

1803169930-07 332.86 39.05 8.524 46.96 9.039 78.42 17.17 18.99

1803169930-08 330.54 38.59 8.566 46.96 8.986 78.33 17.05 18.86

Average 331.38 38.82 8.537 46.94 9.025 78.22 17.09 18.91

Page 10: TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality · TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19631307.002

8 / 17

TUV Rheinland(India) Pvt.Ltd, Plot No.17B,Electronic city, Phase II,Begur Hobli,Bangalore(south)-560 100,India, Report.no:19631307 001

Tel: +91 80 3923430, Fax:+91 80 3055 4342 Mail: [email protected] Web: www.ind.tuv.com - CIN:U72501KA1996PTC020653

Table 7: Averaging of three test modules (continued)

Irrad [W/m

2]

Temp. [⁰C]

Sample no. Pmax [W]

Vmax [V]

Imax [A]

Voc [V]

Isc [A]

FF [%]

M.Eff [%]

C.Eff [%]

800

75

1803169930-06 205.01 29.85 6.867 37.75 7.589 71.56 13.22 14.62

1803169930-07 206.94 29.99 6.901 37.86 7.591 71.99 13.34 14.76

1803169930-08 206.19 30.02 6.869 37.94 7.562 71.87 13.30 14.71

Average 206.05 29.95 6.879 37.85 7.581 71.81 13.29 14.70

50

1803169930-06 233.82 33.91 6.895 41.71 7.477 74.98 15.08 16.68

1803169930-07 235.25 33.89 6.942 41.71 7.468 75.52 15.17 16.78

1803169930-08 233.14 33.88 6.880 41.69 7.434 75.21 15.03 16.63

Average 234.07 33.89 6.906 41.70 7.460 75.24 15.09 16.70

47

1803169930-06 237.35 33.83 7.016 42.15 7.465 75.43 15.31 16.93

1803169930-07 237.08 33.94 6.985 42.17 7.428 75.69 15.29 16.91

1803169930-08 236.01 33.90 6.963 42.19 7.416 75.43 15.22 16.83

Average 236.81 33.89 6.988 42.17 7.436 75.52 15.27 16.89

25

1803169930-06 255.53 36.91 6.924 45.12 7.353 77.03 16.48 18.23

1803169930-07 258.52 37.76 6.846 45.09 7.309 78.44 16.67 18.44

1803169930-08 257.47 37.39 6.887 45.15 7.282 78.32 16.60 18.36

Average 257.17 37.35 6.886 45.12 7.315 77.93 16.58 18.34

15

1803169930-06 266.60 38.90 6.853 46.51 7.245 79.12 17.19 19.02

1803169930-07 267.14 38.93 6.862 46.44 7.247 79.38 17.23 19.05

1803169930-08 266.07 38.89 6.841 46.53 7.204 79.37 17.16 18.98

Average 266.60 38.91 6.852 46.49 7.232 79.29 17.19 19.02

600

75

1803169930-06 154.32 29.13 5.297 37.27 5.721 72.38 13.27 14.68

1803169930-07 154.49 29.73 5.197 37.14 5.709 72.85 13.28 14.69

1803169930-08 154.40 29.86 5.171 37.20 5.689 72.96 13.28 14.68

Average 154.40 29.57 5.222 37.20 5.706 72.73 13.28 14.68

50

1803169930-06 176.33 33.61 5.246 41.25 5.625 75.99 15.16 16.77

1803169930-07 175.00 33.36 5.246 41.10 5.606 75.96 15.05 16.64

1803169930-08 174.66 33.36 5.236 41.03 5.590 76.15 15.02 16.61

Average 175.33 33.44 5.243 41.13 5.607 76.03 15.08 16.67

25

1803169930-06 192.85 37.01 5.211 44.56 5.522 78.38 16.58 18.34

1803169930-07 193.50 37.61 5.145 44.52 5.496 79.09 16.64 18.40

1803169930-08 192.65 37.68 5.112 44.59 5.472 78.95 16.56 18.32

Average 193.00 37.43 5.156 44.56 5.497 78.81 16.59 18.35

15

1803169930-07 199.96 38.38 5.210 45.92 5.447 79.95 17.19 19.02

1803169930-06 198.31 38.73 5.120 45.81 5.443 79.54 17.05 18.86

1803169930-08 199.48 38.77 5.145 45.98 5.417 80.10 17.15 18.97

Average 199.25 38.63 5.158 45.90 5.436 79.86 17.13 18.95

Page 11: TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality · TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19631307.002

9 / 17

TUV Rheinland(India) Pvt.Ltd, Plot No.17B,Electronic city, Phase II,Begur Hobli,Bangalore(south)-560 100,India, Report.no:19631307 001

Tel: +91 80 3923430, Fax:+91 80 3055 4342 Mail: [email protected] Web: www.ind.tuv.com - CIN:U72501KA1996PTC020653

Table 7: Averaging of three test modules (continued)

Irrad [W/m

2]

Temp. [⁰C]

Sample no. Pmax [W]

Vmax [V]

Imax [A]

Voc [V]

Isc [A]

FF [%]

M.Eff [%]

C.Eff [%]

500 15

1803169930-08 165.00 38.97 4.234 45.58 4.503 80.41 17.02 18.83

1803169930-06 164.93 38.51 4.283 45.60 4.528 79.88 17.02 18.82

1803169930-07 165.41 38.36 4.312 45.60 4.512 80.39 17.07 18.88

Average 165.11 38.61 4.276 45.59 4.514 80.23 17.04 18.84

400

50

1803169930-06 115.43 32.89 3.510 40.24 3.738 76.74 14.89 16.47

1803169930-07 115.50 33.06 3.493 40.19 3.731 77.02 14.90 16.48

1803169930-08 115.52 33.22 3.478 40.16 3.722 77.27 14.90 16.48

Average 115.48 33.06 3.494 40.20 3.730 77.01 14.90 16.48

25

1803169930-06 127.37 36.66 3.475 43.65 3.682 79.24 16.43 18.17

1803169930-07 127.92 36.71 3.485 43.70 3.665 79.88 16.50 18.25

1803169930-08 127.10 36.39 3.493 43.75 3.642 79.77 16.39 18.13

Average 127.46 36.59 3.484 43.70 3.663 79.63 16.44 18.18

15

1803169930-07 132.01 38.25 3.451 45.09 3.628 80.68 17.03 18.83

1803169930-06 131.19 38.49 3.408 45.04 3.630 80.24 16.92 18.71

1803169930-08 131.40 38.50 3.413 45.13 3.607 80.73 16.95 18.75

Average 131.53 38.41 3.424 45.09 3.622 80.55 16.97 18.76

200

25

1803169930-06 62.46 35.79 1.745 42.23 1.861 79.47 16.11 17.82

1803169930-07 62.53 35.98 1.738 42.31 1.852 79.78 16.13 17.84

1803169930-08 62.45 36.11 1.730 42.32 1.843 80.08 16.11 17.82

Average 62.48 35.96 1.738 42.29 1.852 79.78 16.12 17.83

15

1803169930-07 64.61 37.49 1.723 43.75 1.829 80.76 16.67 18.43

1803169930-06 64.58 37.42 1.726 43.68 1.836 80.51 16.66 18.42

1803169930-08 64.42 37.37 1.724 43.70 1.824 80.83 16.62 18.38

Average 64.54 37.43 1.724 43.71 1.830 80.70 16.65 18.41

100

25

1803169930-06 30.45 34.53 0.882 40.79 0.949 78.72 15.71 17.38

1803169930-07 30.59 35.11 0.871 40.82 0.945 79.31 15.78 17.46

1803169930-08 30.55 35.04 0.872 40.89 0.940 79.46 15.76 17.43

Average 30.53 34.89 0.875 40.83 0.945 79.16 15.75 17.42

15

1803169930-07 31.71 36.46 0.870 42.43 0.935 79.95 16.36 18.09

1803169930-06 31.49 36.13 0.871 42.28 0.936 79.59 16.24 17.97

1803169930-08 31.43 36.66 0.857 42.32 0.929 79.93 16.21 17.93

Average 31.54 36.42 0.866 42.34 0.933 79.82 16.27 18.00

Page 12: TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality · TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19631307.002

10 / 17

TUV Rheinland(India) Pvt.Ltd, Plot No.17B,Electronic city, Phase II,Begur Hobli,Bangalore(south)-560 100,India, Report.no:19631307 001

Tel: +91 80 3923430, Fax:+91 80 3055 4342 Mail: [email protected] Web: www.ind.tuv.com - CIN:U72501KA1996PTC020653

Tables 8: Test matrix of module performance with respect to temperature and irradiance

Table 8.1: Pmax [W] versus irradiance and temperature

Irradiance Spectrum Module temperature

15 ⁰C 25 ⁰C NOCT ⁰C 50 ⁰C 75 ⁰C

1100 W/m2 AM 1.5 NA 351.80 NA 318.20 279.12

1000 W/m2 AM 1.5 331.38 321.50 NA 292.07 257.54

800 W/m2 AM 1.5 266.60 257.17 236.81 234.07 206.05

600 W/m2 AM 1.5 199.25 193.00 NA 175.33 154.40

500 W/m2 AM 1.5 165.11 NA NA NA NA

400 W/m2 AM 1.5 131.53 127.46 NA 115.48 NA

200 W/m2 AM 1.5 64.54 62.48 NA NA NA

100 W/m2 AM 1.5 31.54 30.53 NA NA NA

Table 8.2: Isc [A] versus irradiance and temperature

Irradiance Spectrum Module temperature

15 ⁰C 25 ⁰C NOCT ⁰C 50 ⁰C 75 ⁰C

1100 W/m2 AM 1.5 NA 10.011 NA 10.201 10.384

1000 W/m2 AM 1.5 9.025 9.124 NA 9.291 9.444

800 W/m2 AM 1.5 7.232 7.315 7.436 7.460 7.581

600 W/m2 AM 1.5 5.436 5.497 NA 5.607 5.706

500 W/m2 AM 1.5 4.514 NA NA NA NA

400 W/m2 AM 1.5 3.622 3.663 NA 3.730 NA

200 W/m2 AM 1.5 1.830 1.852 NA NA NA

100 W/m2 AM 1.5 0.933 0.945 NA NA NA

Table 8.3: Voc [V] versus irradiance and temperature

Irradiance Spectrum Module temperature

15 ⁰C 25 ⁰C NOCT ⁰C 50 ⁰C 75 ⁰C

1100 W/m2 AM 1.5 NA 45.75 NA 42.36 38.51

1000 W/m2 AM 1.5 46.94 45.60 NA 42.21 38.47

800 W/m2 AM 1.5 46.49 45.12 42.17 41.70 37.85

600 W/m2 AM 1.5 45.90 44.56 NA 41.13 37.20

500 W/m2 AM 1.5 45.59 NA NA NA NA

400 W/m2 AM 1.5 45.09 43.70 NA 40.20 NA

200 W/m2 AM 1.5 43.71 42.29 NA NA NA

100 W/m2 AM 1.5 42.34 40.83 NA NA NA

Page 13: TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality · TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19631307.002

11 / 17

TUV Rheinland(India) Pvt.Ltd, Plot No.17B,Electronic city, Phase II,Begur Hobli,Bangalore(south)-560 100,India, Report.no:19631307 001

Tel: +91 80 3923430, Fax:+91 80 3055 4342 Mail: [email protected] Web: www.ind.tuv.com - CIN:U72501KA1996PTC020653

Table 8.4: Vmax [V] versus irradiance and temperature

Irradiance Spectrum Module temperature

15 ⁰C 25 ⁰C NOCT ⁰C 50 ⁰C 75 ⁰C

1100 W/m2 AM 1.5 NA 37.21 NA 33.60 29.60

1000 W/m2 AM 1.5 38.82 37.32 NA 34.01 29.92

800 W/m2 AM 1.5 38.91 37.35 33.89 33.89 29.95

600 W/m2 AM 1.5 38.63 37.43 NA 33.44 29.57

500 W/m2 AM 1.5 38.61 NA NA NA NA

400 W/m2 AM 1.5 38.41 36.59 NA 33.06 NA

200 W/m2 AM 1.5 37.43 35.96 NA NA NA

100 W/m2 AM 1.5 36.42 34.89 NA NA NA

Table 8.5: Imax [A] versus irradiance and temperature

Irradiance Spectrum Module temperature

15 ⁰C 25 ⁰C NOCT ⁰C 50 ⁰C 75 ⁰C

1100 W/m2 AM 1.5 NA 9.455 NA 9.470 9.431

1000 W/m2 AM 1.5 8.537 8.616 NA 8.589 8.607

800 W/m2 AM 1.5 6.852 6.886 6.988 6.906 6.879

600 W/m2 AM 1.5 5.158 5.156 NA 5.243 5.222

500 W/m2 AM 1.5 4.276333 NA NA NA NA

400 W/m2 AM 1.5 3.424 3.484 NA 3.494 NA

200 W/m2 AM 1.5 1.724 1.738 NA NA NA

100 W/m2 AM 1.5 0.866 0.875 NA NA NA

Table 9: Summary of reference power conditions (at AM 1,5)

Irrad [W/m

2]

Temp. [⁰C]

Pmax [W]

Vmax [V]

Imax [A]

Voc [V]

Isc [A]

FF [%]

M.Eff [%]

C.Eff [%]

1000 25 321.50 37.32 8.616 45.60 9.124 77.28 16.59 18.35

800 NOCT 236.81 33.89 6.988 42.17 7.436 75.52 15.27 16.89

200 25 62.48 35.96 1.738 42.29 1.852 79.78 16.12 17.83

1000 75 257.54 29.92 8.607 38.47 9.444 70.89 13.29 14.70

500 15 165.11 38.61 4.276 45.59 4.514 80.23 17.04 18.84

Page 14: TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality · TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19631307.002

12 / 17

TUV Rheinland(India) Pvt.Ltd, Plot No.17B,Electronic city, Phase II,Begur Hobli,Bangalore(south)-560 100,India, Report.no:19631307 001

Tel: +91 80 3923430, Fax:+91 80 3055 4342 Mail: [email protected] Web: www.ind.tuv.com - CIN:U72501KA1996PTC020653

Table 10: Maximum power determination after matrix generation

Test date [DD/MM/YYYY]: 13-05-2017 to 15-05-2017

Module temperature °C: Corrected to 25

Irradiance W/m²: ……. 1000

Sample no. Pmax W Vmax V ImaxA Voc V Isc A FF % M.efficy in [%]

C.efficy in [%]

Rsh in ohms

Rs in ohms

1803169930-05 324.11 37.16 8.722 45.70 9.190 77.17 16.72 18.49 306.88 0.532

1803169930-06 322.56 37.17 8.679 45.65 9.223 76.62 16.64 18.41 145.57 0.532

1803169930-07 323.54 37.16 8.706 45.62 9.185 77.21 16.69 18.46 502.05 0.523

1803169930-08 321.96 37.23 8.648 45.65 9.160 77.00 16.61 18.37 572.79 0.536

Supplementary information: None

Table 11: Comparison of measured power with name plate of the module after matrix generation

Test date [DD/MM/YYYY]:… 13-05-2017 to 15-05-2017

Sample no. Power measured at STC after

matrix in [W] Power on name plate -

1803169930-05 324.11

320 W 0/+5W

P

1803169930-06 322.56 P

1803169930-07 323.54 P

1803169930-08 321.96 P

Supplementary information: None

Table 12: Measurement of temperature coefficients

Test date [DD/MM/YYYY]……………….… 09-05-2017

Ambient air temperature °C ……………... 25 ± 2

Irradiance W/m² …………………………… 1000

Module temperature °C high/low ………… 65 / 25

Sample No.

1803169930-02 + 0.0676 - 0.3121 - 0.4003

1803169930-03 + 0.0680 - 0.3089 - 0.3941

1803169930-04 + 0.0705 - 0.3104 - 0.3901

Average + 0.0687 - 0.3104 - 0.3948

Supplementary information: None

Page 15: TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality · TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19631307.002

13 / 17

TUV Rheinland(India) Pvt.Ltd, Plot No.17B,Electronic city, Phase II,Begur Hobli,Bangalore(south)-560 100,India, Report.no:19631307 001

Tel: +91 80 3923430, Fax:+91 80 3055 4342 Mail: [email protected] Web: www.ind.tuv.com - CIN:U72501KA1996PTC020653

Annex 1: Measurement Curve

Measurement curve after preconditioning

1803169930-05 1803169930-06

1803169930-07 1803169930-08

Page 16: TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality · TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19631307.002

14 / 17

TUV Rheinland(India) Pvt.Ltd, Plot No.17B,Electronic city, Phase II,Begur Hobli,Bangalore(south)-560 100,India, Report.no:19631307 001

Tel: +91 80 3923430, Fax:+91 80 3055 4342 Mail: [email protected] Web: www.ind.tuv.com - CIN:U72501KA1996PTC020653

Measurement curve after matrix generation

1803169930-05 1803169930-06

1803169930-07 1803169930-08

Page 17: TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality · TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19631307.002

15 / 17

TUV Rheinland(India) Pvt.Ltd, Plot No.17B,Electronic city, Phase II,Begur Hobli,Bangalore(south)-560 100,India, Report.no:19631307 001

Tel: +91 80 3923430, Fax:+91 80 3055 4342 Mail: [email protected] Web: www.ind.tuv.com - CIN:U72501KA1996PTC020653

Annex 2: Equipment used

Equipment Equipment ID Cal Due date

Pasan Sun Simulator-3b 50-2010-0111 22-05-2017

Reference Module 50-2012-0230 15-08-2017

Reference cell - WPVS-RS-ID-4 50-2010-0111C 11-11-2017

Annex 3: Statement of the estimated uncertainty of the test verdicts and spectrum at test plane

- Electrical performance rating is outside the scope of IEC 61215:2005 qualification testing. The verdicts of

performance rating are only related to the test samples that were subjected to the tests. They cannot be

generalised to the modules from the series production.

- Pmax measurement:2.45% with a coverage factor k=2

- Current measurement:2.27% with a coverage factor k=2`

- Voltage measurement:1.39% with a coverage factor k=2

- Relative measurements were performed with a flash type solar simulator.

The accuracy of measurement reproduction with the solar simulator is less than 1%.

Page 18: TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality · TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19631307.002

16 / 17

TUV Rheinland(India) Pvt.Ltd, Plot No.17B,Electronic city, Phase II,Begur Hobli,Bangalore(south)-560 100,India, Report.no:19631307 001

Tel: +91 80 3923430, Fax:+91 80 3055 4342 Mail: [email protected] Web: www.ind.tuv.com - CIN:U72501KA1996PTC020653

Annex 4: Pictures of Test Samples

Fig.01: Front view of test sample Fig. 02: Rear view of test sample

Fig. 03: Detail view of Junction Box Fig. 04: Detail view of Type label

Page 19: TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality · TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19631307.002

17 / 17

TUV Rheinland(India) Pvt.Ltd, Plot No.17B,Electronic city, Phase II,Begur Hobli,Bangalore(south)-560 100,India, Report.no:19631307 001

Tel: +91 80 3923430, Fax:+91 80 3055 4342 Mail: [email protected] Web: www.ind.tuv.com - CIN:U72501KA1996PTC020653

Fig. 05: Detail view of Solar cell Fig. 06: Detail view of connector

Fig. 07: Detail view of Solar cable Fig. 08: Detail view of serial number

Annex 5: Serial numbers

----------------END OF REPORT--------------