Tungsten HCAL simulation studies

20
Tungsten HCAL simulation studies Peter Speckmayer CLIC 09 12 – 16 October 2009 15/10/2009 1 CLIC09, Peter Speckmayer

description

Tungsten HCAL simulation studies. Peter Speckmayer CLIC 09 12 – 16 October 2009. considerations for HCAL depth and material. shower leakage worsens energy resolution to reduce leakage: deeper calorimeter  denser calorimeter (more interaction lengths) - PowerPoint PPT Presentation

Transcript of Tungsten HCAL simulation studies

Page 1: Tungsten HCAL simulation studies

CLIC09, Peter Speckmayer 1

Tungsten HCAL simulation studies

Peter SpeckmayerCLIC 09

12 – 16 October 2009

15/10/2009

Page 2: Tungsten HCAL simulation studies

CLIC09, Peter Speckmayer 2

considerations for HCAL depth and materialshower leakage worsens energy resolution

to reduce leakage:deeper calorimeterdenser calorimeter (more interaction lengths)

depth limited by feasible coil size:larger coil with smaller B-fieldlarger B-field with smaller coil

depth limited by tracker size:larger tracker better p-resolution

15/10/2009

IP beam

COIL

HCAL

Tracker

ECAL

Vertex

Barrel Endcaphere would be a tail-catcher

Page 3: Tungsten HCAL simulation studies

CLIC09, Peter Speckmayer 3

HCAL absorber material which material for the absorber?

steel, tungsten, ... ?

Tungstenexpensive!more contained showers (compared to Fe) with the same

HCAL geometrical depth less leakagesmaller shower diameter better separation of showers

(probably good for particle flow)

final goal good energy resolution with whole detector

15/10/2009

Page 4: Tungsten HCAL simulation studies

CLIC09, Peter Speckmayer 4

Energy reconstruction with neuronal network

15/10/2009

shorter HCAL more leakage worse resolution

numbers denote HCAL length inunits of interaction lengths

~40 λ

5 mm scintillator, 2.5 mm G10

(information from fine granularity of calorimeter not used traditional approach)-variables describe shower shape and size and energy-train NN with pion energy

steel

tungsten

Page 5: Tungsten HCAL simulation studies

CLIC09, Peter Speckmayer 5

Tail-catcher

15/10/2009

tungsten

coil thickness: 2 λzero λ tail-catcher implies no active material after the coilhaving some tail-catcher (1 λ) improves resolutioneffect of bigger tail-catcher is small

Page 6: Tungsten HCAL simulation studies

CLIC09, Peter Speckmayer 6

Tungsten HCALTungsten used in ECALs

typically ~1λ deepNo experience with tungsten HCALs

~4 – 9 λ deep

simulation of tungsten not validatedno MC/data comparisonsno validation for high granularity

If tungsten is used have to be sure, that energy resolution of whole detector is better (PFA)

15/10/2009

Page 7: Tungsten HCAL simulation studies

CLIC09, Peter Speckmayer 7

physics-list differences (Geant4)simulations of pion showers in block of tungsten

tungsten, QGSP_BERT tungsten, QGSP_BERT_HP

Evisible/EMC

transition regions of modelswith HP (high precision neutron tracking) enabled much less energy deposit by ionization

which one can we trust more?

15/10/2009

Evisible/EMC

in QGSP_BERT more n produced, more n captured ~8MeV of photons each accounts for difference

Page 8: Tungsten HCAL simulation studies

CLIC09, Peter Speckmayer 8

lead, QGSP_BERTtungsten, QGSP_BERT_HP

similar widths of lead and tungsten, when HP is used

“feeling” says: this is more trustworthy

lead simulations for hadrons are better validated

15/10/2009

Evisible/EMCEvisible/EMC

physics-list differences (Geant4)simulations of pion showers in block of lead/tungsten

Page 9: Tungsten HCAL simulation studies

CLIC09, Peter Speckmayer 9

Effect of physics list on predicted resolution

15/10/2009

5 mm scintillator, 2.5 mm G10

~10-15% improvement (at 40 GeV)

why: n are captured farther away from shower core “halo” produced which reduces reconstruction performance. removing halo (with HP n tracking)

less energy deposited by ionization, but ... Improved resolution!

considerable effectbut: perfect readout assumed

Page 10: Tungsten HCAL simulation studies

CLIC09, Peter Speckmayer 10

Further reason for validation

Time structure of signal broadened by n-contenttime stamping

used to separate signal/background on a time basis (slow) n-content smears out energy deposits in

calorimeters know time-structure of n-content to set

requirements for time stampingdependent on active material (e.g. scintillator,

gas)measurements necessary15/10/2009

Page 11: Tungsten HCAL simulation studies

CLIC09, Peter Speckmayer 11

Particle flow results so farComparison of around 8 ½ interaction lengths of HCAL with Fe and WW delivers comparable resolution to Feno optimization of the PFA for W done

15/10/2009

Angela Lucaci-Timoce

Page 12: Tungsten HCAL simulation studies

CLIC09, Peter Speckmayer 12

Tungsten HCAL PrototypeWhat can we learn?Physics performance

Verify simulations (resolution, shower shapes, ...)Include realistic noise levels (read-out, neutrons,

...)

Tungsten plate production processTest production of large thin platesFeasibility of needed flatnessMachining of tungsten platesBolting, cutouts

15/10/2009

Page 13: Tungsten HCAL simulation studies

CLIC09, Peter Speckmayer 13

Longitudinal shower size

15/10/2009

C. Grefe

95% contained energy → ~40 layers (~4.8 λ)

95%

12 mm tungsten + 5 mm Scint + 2.5 G10

Page 14: Tungsten HCAL simulation studies

CLIC09, Peter Speckmayer 14

Lateral shower size

15/10/2009

C. Grefe

95% contained energy → ~40 cm radius

95%

12 mm tungsten + 5 mm Scint + 2.5 G10

Page 15: Tungsten HCAL simulation studies

CLIC09, Peter Speckmayer 15

Longitudinal shower sizes: tungsten + micromegas

15/10/2009

J. Blaha

95%

11 mm tungsten + micromegas

Page 16: Tungsten HCAL simulation studies

CLIC09, Peter Speckmayer 16

Lateral shower sizes: tungsten + micromegas

15/10/2009

J. Blaha

Page 17: Tungsten HCAL simulation studies

CLIC09, Peter Speckmayer 17

more about prototype

see following talk by W.Klempt

15/10/2009

Page 18: Tungsten HCAL simulation studies

CLIC09, Peter Speckmayer 18

Conclusions & OutlookFrom tungsten simulations:

8-9 λ ’s ECAL+HCAL seems sufficient up to 300 GeV (pions)

~10-15 mm W absorber optimaltail catcher usefulchoice of GEANT4 physics list important (different

results for W simulations)Particle Flow algorithm W and Fe first results are

comparable will be extended

From future prototype results:feed back prototype to G4-team

15/10/2009

Page 19: Tungsten HCAL simulation studies

CLIC09, Peter Speckmayer 19

backup

15/10/2009

Page 20: Tungsten HCAL simulation studies

CLIC09, Peter Speckmayer 20

Tail-catcher

15/10/2009

coil thickness: 2 λzero λ tail-catcher implies no active material after the coilhaving some tail-catcher (1 λ) improves resolutioneffect of bigger tail-catcher is small

tungsten steel