TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

126
FTTH Fundamental Planning and Design David Stallworth [email protected] 770-798-2423

description

FTTH

Transcript of TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Page 1: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

FTTH

Fun

dam

enta

l Pla

nnin

g an

d D

esig

nD

avid

Sta

llwor

th

dsta

llwor

th@

ofso

ptic

s.co

m

770-

798-

2423

Page 2: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design
Page 3: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design
Page 4: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

This

pre

sent

atio

n ap

plie

s to

FTTH

(Fib

er to

the

Hom

e/Pr

emis

e/x

GPO

N, B

PON

, EPO

N)

and

RFO

G(R

F O

VER

GLA

SS)

Page 5: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Let�s

say

you

are

goi

ng to

pla

ce F

TTx

to

all l

ivin

g an

d bu

sine

ss u

nits

in

the

city

bel

ow :

Page 6: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Or y

ou a

re g

oing

to p

lace

cab

le

in a

new

dev

elop

men

t:

Page 7: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Whe

re s

houl

d th

e hu

b/he

aden

d/

cent

ral o

ffice

be

plac

ed?

How

man

y fe

eder

rout

es?

Whe

re s

houl

d th

e fe

eder

rout

es b

e pl

aced

?

Whe

re d

o th

e br

anch

feed

er ro

utes

go?

Whe

re s

houl

d th

e fe

eder

bou

ndar

ies

be p

lace

d?

Whe

re s

houl

d th

e sp

litte

rs b

e pl

aced

?

Page 8: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

WH

AT

AR

E A

LL T

HE

CO

STS

TO C

ON

SID

ER?

AR

E TH

ERE

AN

Y R

ELA

TIO

NSH

IPS

BET

WEE

N C

OST

S?

HEA

DEN

D

ELEC

TRO

NIC

S(O

ptic

al L

ine

Car

d)

FIB

ER

TER

MIN

ATI

ON

FEED

ER C

AB

LEC

ENTR

ALI

ZED

CA

BIN

ET

CEN

TRA

LIZE

D O

R

DIS

TRIB

UTE

D S

PLIT

TER

PON

DIS

TRIB

UTI

ON

C

AB

LE

PON

DR

OP

CLO

SUR

ES

CU

STO

MER

END

EL

ECTR

ON

ICSFI

BER

DR

OP

DR

OP

CO

NN

ECTO

RS SP

LITT

ERC

ON

NEC

TOR

S

AR

E TH

ERE

AN

Y O

THER

FA

CTO

RS

TO C

ON

SID

ER?

Page 9: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

CU

STO

MER

TA

KE

RA

TE

GEO

GR

APH

Y

CO

NTR

AC

TOR

PLA

CIN

G C

OST

AB

OVE

OR

BEL

OW

GR

OU

ND

INFR

AST

RU

CTU

RE

OTH

ER F

AC

TOR

S TO

CO

NSI

DER

:

Page 10: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

You

r Dyn

amic

s m

atte

r:Ta

ke R

ate

Take

Rat

eLa

bor R

ate

Labo

r Rat

eH

ousi

ng D

ensi

tyH

ousi

ng D

ensi

ty

Page 11: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

PO

N D

IST

RIB

UT

ION

C

AB

LE

PO

N D

RO

P C

LO

SU

RE

SS

PL

ITT

ER

LO

CA

TIO

N

FIB

ER

DR

OP

DR

OP

CO

NT

RA

CT

CO

ST

S

HEAD

END

ELE

CTRO

NICS

SPLI

TTER

LO

CATI

ON

DIST

RIBU

TED

SPLI

TTER

SCE

NTRA

LIZE

D CA

BINE

T

TAKE

RAT

E

FEED

ER C

ABLE

PON

DESI

GN

SPLI

TTER

CONN

ECTO

RSDR

OP

CONN

ECTO

RSFU

SIO

N SP

LICI

NG

INST

ALLA

TIO

N LA

BOR

CONS

TRUC

TIO

N LA

BOR

HEL

P!H

ELP!

Page 12: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

WE

NEE

D A

WA

Y TO

EXA

MIN

E TH

OSE

REL

ATI

ON

SHIP

S TO

GET

HER

WE

NEE

D A

WA

Y TO

DEC

IDE

WH

AT

DES

IGN

IS B

EST

Page 13: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

OPT

ICO

STO

PTIC

OST

©©M

OD

ELS

MO

DEL

SPR

OVI

DE

PRO

VID

ETH

E A

NSW

ERTH

E A

NSW

ER

Page 14: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design
Page 15: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Idea

l Loc

atio

n?Id

eal L

ocat

ion?

(cla

ssic

cos

t (c

lass

ic c

ost

stud

y te

chni

que)

stud

y te

chni

que)

Page 16: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

AN

IDEA

L A

REA

EAC

H S

QU

AR

E IS

EA

CH

SQ

UA

RE

IS

A 3

2 H

OM

E PO

NA

32

HO

ME

PON

EAC

H S

QU

AR

E IS

EA

CH

SQ

UA

RE

IS

500�

LO

NG

AN

D50

0� L

ON

G A

ND

500�

WID

E50

0� W

IDE

TOTA

L A

REA

HA

STO

TAL

AR

EA H

AS

2048

LIV

ING

UN

ITS

2048

LIV

ING

UN

ITS

AN

D 6

4 PO

NS

AN

D 6

4 PO

NS

CA

BIN

ET A

REA

SIZ

E TO

STU

DY:

CA

BIN

ET A

REA

SIZ

E TO

STU

DY:

1 PO

N U

P TO

32

PON

S PE

R C

AB

INET

AR

EA1

PON

UP

TO 3

2 PO

NS

PER

CA

BIN

ET A

REA

OR

32

TO 1

024

LIVI

NG

UN

ITS

OR

32

TO 1

024

LIVI

NG

UN

ITS

Page 17: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Dro

p C

losu

reD

rop

Clo

sure

Aer

ial

Aer

ial

Dis

trib

utio

n D

istr

ibut

ion

Cab

leC

able

Dro

p C

able

D

rop

Cab

le

Pede

stal

Pede

stal

(Dro

p (D

rop

Clo

sure

) C

losu

re)

MD

UB

urie

d D

istr

ibut

ion

Cab

leB

urie

d D

istr

ibut

ion

Cab

le

MD

U

MD

U

Term

inat

ion

Term

inat

ion

Cen

tral

Offi

ce /

Hea

d En

d

Cen

tral

ized

Cab

inet

Loc

atio

nC

entr

aliz

ed C

abin

et L

ocat

ion ss

Dro

p C

losu

reD

rop

Clo

sure

Sing

le

Fam

ily

Res

iden

tial

OFS

Opt

iCos

t O

FS O

ptiC

ost ©©

Mod

els

Mod

els

Gui

delin

es fo

r sel

ectin

g th

e rig

ht s

olut

ion

Gui

delin

es fo

r sel

ectin

g th

e rig

ht s

olut

ion

Page 18: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Whe

re s

houl

d th

e hu

b/he

aden

d/

cent

ral o

ffice

be

plac

ed?

Page 19: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Idea

l Hub

/Nod

e Pl

acem

ent

Idea

l Hub

/Nod

e Pl

acem

ent

65

43

34

56

55

32

23

55

43

31

13

34

32

11

11

23

32

11

11

23

65

43

34

56

55

32

23

55

43

31

13

34

88

66

43

34

77

55

32

23

66

44

21

12

54

32

11

11

54

32

11

11

66

44

21

12

77

55

32

23

88

66

43

34

109

87

65

43

109

87

65

43

109

87

65

43

109

87

65

43

87

65

43

21

87

65

43

21

87

65

43

21

87

65

43

21

Page 20: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Idea

l Hub

/Nod

e Pl

acem

ent

Idea

l Hub

/Nod

e Pl

acem

ent

Var

ianc

e fr

om Id

eal

050100

150

200

250

300

350

400

12

34

Cos

t var

ianc

e fr

om id

eal

CostC

ost i

ncre

ase

from

Idea

l

Page 21: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Idea

l Hub

/Nod

e Pl

acem

ent

Idea

l Hub

/Nod

e Pl

acem

ent

Hub

/N

ode

Plac

e in

geo

grap

hica

l cen

ter

Why

?Pr

ovid

e 20

km re

ach

to a

ll su

bscr

iber

s

20 k

m

Serv

ing

Are

a B

ound

ary

Page 22: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Idea

l Hub

/Nod

e Pl

acem

ent

Idea

l Hub

/Nod

e Pl

acem

ent

Hub

/N

ode

Serv

ing

Are

a B

ound

ary

Plac

e in

livi

ng u

nit d

ensi

ty c

ente

r

Why

?M

inim

ize

cabl

e le

ngth

san

d si

zes

Page 23: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Idea

l Hub

/Nod

e Pl

acem

ent

Idea

l Hub

/Nod

e Pl

acem

ent

Hub

/N

ode

Plac

e in

geo

grap

hica

l cen

ter

Why

?Pr

ovid

e 20

km re

ach

to a

ll su

bscr

iber

s

20 k

m

Serv

ing

Are

a B

ound

ary

Why

?M

inim

ize

cabl

e le

ngth

san

d si

zes

Plac

e in

livi

ng u

nit d

ensi

ty c

ente

r

Page 24: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Idea

l Hub

/Nod

e Pl

acem

ent

Idea

l Hub

/Nod

e Pl

acem

ent

Hub

/N

ode

Plac

e in

geo

grap

hica

l cen

ter

Det

erm

ine

the

optim

um m

ixof

geo

grap

hica

l and

den

sity

cen

ter

20 k

m

Serv

ing

Are

a B

ound

ary

Plac

e in

livi

ng u

nit d

ensi

ty c

ente

r

Page 25: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Idea

l Loc

atio

nId

eal L

ocat

ion

Page 26: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Wha

t abo

ut n

ew d

evel

opm

ents

:W

hat a

bout

new

dev

elop

men

ts:

Idea

l Hub

/Nod

e Pl

acem

ent

Idea

l Hub

/Nod

e Pl

acem

ent

Page 27: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

The

sam

e m

etho

ds a

pply

to d

evel

opm

ents

:G

eogr

aphi

cal c

ente

ran

d D

ensi

ty c

ente

r

Idea

l Hub

/Nod

e Pl

acem

ent

Idea

l Hub

/Nod

e Pl

acem

ent

Idea

l Loc

atio

n

Gen

eral

ly, D

ensi

ty C

ente

r is

mor

e cr

itica

l

Page 28: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

The

prob

lem

:D

evel

opm

ents

bui

lt in

pha

ses

Idea

l Hub

/Nod

e Pl

acem

ent

Idea

l Hub

/Nod

e Pl

acem

ent P

hase

1

Use

bes

t loc

atio

n av

aila

ble-

not a

t the

fron

t

Pha

se 2

Pha

se 3

Page 29: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Whe

re s

houl

d an

Opt

ical

Sp

litte

r Cab

inet

be

plac

ed?

Page 30: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

SPLI

TTER

CA

BIN

ETSP

LITT

ER C

AB

INET

-- WH

ERE

TO P

LAC

E IT

WH

ERE

TO P

LAC

E IT

10 32 H

OM

EP

ON

AR

EA

STH

E ID

EAL

PLA

CE

IS IN

TH

E M

IDD

LEO

F TH

E A

REA

TH

E C

AB

INET

WIL

LSE

RVE

Page 31: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

MU

LTIP

LE C

AB

INET

PLA

CEM

ENT

MU

LTIP

LE C

AB

INET

PLA

CEM

ENT

10 32 H

OM

EP

ON

AR

EAS

USE

160

HO

ME

CAB

INE

T

Page 32: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

How

big

sho

uld

the

cabi

net b

e?H

ow m

any

hom

es s

erve

d fro

m o

ne

cabi

net?

Page 33: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

AN

IDEA

L A

REA

EAC

H S

QU

AR

E IS

EA

CH

SQ

UA

RE

IS

A 3

2 H

OM

E PO

NA

32

HO

ME

PON

EAC

H S

QU

AR

E IS

EA

CH

SQ

UA

RE

IS

500�

LO

NG

AN

D50

0� L

ON

G A

ND

500�

WID

E50

0� W

IDE

TOTA

L A

REA

HA

STO

TAL

AR

EA H

AS

2048

LIV

ING

UN

ITS

2048

LIV

ING

UN

ITS

AN

D 6

4 PO

NS

AN

D 6

4 PO

NS

Page 34: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

6 C

AB

INET

SIZ

E PL

AN

S6

CA

BIN

ET S

IZE

PLA

NS

1024

Hom

es/

cabi

net

512

Hom

es/

cabi

net

256

Hom

es/

cabi

net

128

Hom

es/

cabi

net

64 Hom

es/

cabi

net

32 Hom

es/

cabi

net

Page 35: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Cab

inet

Siz

e:

Cos

t Mod

els

stud

ies

vario

us c

abin

et s

izes

Cos

t Mod

els

stud

ies

vario

us c

abin

et s

izes

Page 36: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

idea

l Cab

inet

Siz

e

1024

5

12

25

6

1

28

6

4

32

Cab

inet

Siz

e

Overall Costs

Cab

inet

Siz

e:

Idea

l Cab

inet

siz

e =

Idea

l Cab

inet

siz

e =

256

Livi

ng U

nits

256

Livi

ng U

nits

Page 37: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

TAKE

RAT

E AN

ALYS

IS

0

500

1000

1500

2000

2500

3000

3500

12

34

56

PLAN

NUM

BER

$/SUB

10%

20%

30%

35%

40%

50%

60%

70%

80%

90%

100%

Page 38: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

CAB

INET

SIZ

E &

HO

USI

NG

DEN

SITY

010

020

030

040

050

060

070

080

090

0

100'

30

0'

500

'

700'

1

000'

15

00'

200

0'

3000

'

COST PER SUB

1028

512

256

128

64 32

Sing

le F

amily

M

DU

�s

63

10.

60.

30.

215

139

Hom

es/ A

cre

Typi

cal U

rban

/Sub

urba

n D

evel

opm

ents

Are

6-8

Hom

es p

er A

cre

for S

ingl

e Fa

mily

PON

Siz

e

Page 39: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

CO

NC

LUSI

ON

SC

ON

CLU

SIO

NS

3. C

O E

LEC

TRO

NIC

S C

OST

AR

E FA

IRLY

INSE

NSI

TVE

WH

EN

3. C

O E

LEC

TRO

NIC

S C

OST

AR

E FA

IRLY

INSE

NSI

TVE

WH

EN

SELE

CTI

NG

CA

BIN

ET S

IZE

SELE

CTI

NG

CA

BIN

ET S

IZE

1. P

ON

AR

EA S

IZE

IS M

OD

ERA

TELY

SEN

SITI

VE:

1. P

ON

AR

EA S

IZE

IS M

OD

ERA

TELY

SEN

SITI

VE:

BIG

GER

PO

NS

PUSH

ES ID

EAL

SIZE

SM

ALL

ERB

IGG

ER P

ON

S PU

SHES

IDEA

L SI

ZE S

MA

LLER

SMA

LLER

PO

NS

PUSH

ES ID

EAL

SIZE

BIG

GER

SMA

LLER

PO

NS

PUSH

ES ID

EAL

SIZE

BIG

GER

2. S

PLIT

TER

CO

ST A

RE

FAIR

LY IN

SEN

SITI

VE W

HEN

SEL

ECTI

NG

2.

SPL

ITTE

R C

OST

AR

E FA

IRLY

INSE

NSI

TIVE

WH

EN S

ELEC

TIN

G

CA

BIN

ET S

IZE

CA

BIN

ET S

IZE

5. C

AB

INET

CO

ST IS

MO

DER

ATE

LY S

ENSI

TIVE

WH

EN S

ELEC

TIN

G

5. C

AB

INET

CO

ST IS

MO

DER

ATE

LY S

ENSI

TIVE

WH

EN S

ELEC

TIN

G

CA

BIN

ET S

IZE

(CO

NSI

DER

$/L

IVIN

G U

NIT

FO

R E

AC

H S

IZE)

C

AB

INET

SIZ

E (C

ON

SID

ER $

/LIV

ING

UN

IT F

OR

EA

CH

SIZ

E)

6. M

OST

EC

ON

OM

ICA

L SI

ZE C

ENTE

RS

AR

OU

ND

256

WH

EN A

LL

6. M

OST

EC

ON

OM

ICA

L SI

ZE C

ENTE

RS

AR

OU

ND

256

WH

EN A

LL

FAC

TOR

S A

RE

CO

NSI

DER

EDFA

CTO

RS

AR

E C

ON

SID

ERED

(MO

ST S

ENSI

TIVE

TO

TA

KE

RA

TE, P

ON

SIZ

E, C

AB

INET

CO

ST)

(MO

ST S

ENSI

TIVE

TO

TA

KE

RA

TE, P

ON

SIZ

E, C

AB

INET

CO

ST)

4. T

AK

E R

ATE

IS V

ERY

SEN

SITI

VE W

HEN

SEL

ECTI

NG

CA

BIN

ET S

IZE

4. T

AK

E R

ATE

IS V

ERY

SEN

SITI

VE W

HEN

SEL

ECTI

NG

CA

BIN

ET S

IZE

Page 40: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

���

even

for a

n op

timis

tic ta

ke��

�ev

en fo

r an

optim

istic

take

-- rat

e, it

isra

te, i

t is

optim

al to

op

timal

to

aggr

egat

e ab

out 1

92ag

greg

ate

abou

t 192

-- 224

hom

es (6

224

hom

es (6

-- 8 s

plitt

ers)

in a

n 8

split

ters

) in

an

urba

n de

ploy

men

t and

96

urba

n de

ploy

men

t and

96 --

128

hom

es in

a ru

ral

128

hom

es in

a ru

ral

depl

oym

ent

depl

oym

ent . .

In th

e ur

ban

cont

ext,

the

low

est c

ost

In th

e ur

ban

cont

ext,

the

low

est c

ost

arch

itect

ure

arch

itect

ure

��ta

king

into

acc

ount

the

addi

tiona

l ta

king

into

acc

ount

the

addi

tiona

l fib

er re

late

d co

sts

and

OLT

por

t sav

ings

fib

er re

late

d co

sts

and

OLT

por

t sav

ings

��ha

s an

has

anO

FAP

(Opt

imal

Fib

er A

ggre

gatio

n Po

int)

size

of

OFA

P (O

ptim

al F

iber

Agg

rega

tion

Poin

t) si

ze o

f ab

out 2

00 h

omes

abou

t 200

hom

es.�.�

Anu

pam

Ban

erje

e, M

arvi

n S

irbu

Car

negi

e M

ello

n U

nive

rsity

Pitt

sbur

gh, P

A�T

owar

ds T

echn

olog

ical

ly a

nd C

ompe

titiv

ely

Neu

tral

Fib

er to

the

Hom

e (F

TTH

) Inf

rast

ruct

ure�

OU

TSID

E VA

LID

ATI

ON

:

Page 41: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

How

man

y fe

eder

rout

es?

Whe

re s

houl

d th

e fe

eder

rout

es b

e pl

aced

?

Whe

re d

o th

e br

anch

feed

er ro

utes

go?

Whe

re s

houl

d th

e fe

eder

bou

ndar

ies

be

plac

ed?

Page 42: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

FEED

ER D

ESIG

NFE

EDER

DES

IGN

Def

initi

ons

Def

initi

ons

CO

OR

HE

AD

EN

D

MA

INFE

ED

ER

BRAN

CH

FEE

DE

R

Page 43: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

IDEA

L FE

EDER

DES

IGN

IDEA

L FE

EDER

DES

IGN

CO

OR

HE

AD

EN

D

FEE

DE

RBO

UN

DAR

Y

FEE

DE

R

Page 44: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Idea

l Hub

/Nod

e Pl

acem

ent

Idea

l Hub

/Nod

e Pl

acem

ent

65

43

34

56

55

32

23

55

43

31

13

34

32

11

11

23

32

11

11

23

65

43

34

56

55

32

23

55

43

31

13

34

88

66

43

34

77

55

32

23

66

44

21

12

54

32

11

11

54

32

11

11

66

44

21

12

77

55

32

23

88

66

43

34

109

87

65

43

109

87

65

43

109

87

65

43

109

87

65

43

87

65

43

21

87

65

43

21

87

65

43

21

87

65

43

21

Page 45: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Idea

l Hub

/Nod

e Pl

acem

ent

Idea

l Hub

/Nod

e Pl

acem

ent

Var

ianc

e fr

om Id

eal

050100

150

200

250

300

350

400

12

34

Cos

t var

ianc

e fr

om id

eal

CostC

ost

incr

ease

from

Idea

l

Page 46: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

FEED

ER D

ESIG

NFE

EDER

DES

IGN

Def

initi

ons

Def

initi

ons

CO

OR

HE

AD

EN

DMA

INFE

EDER

BR

AN

CH

FEED

ER

Des

ign

to la

st

At l

east

10

year

s

Des

ign

for t

he

Ulti

mat

e ne

eds

Page 47: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design
Page 48: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design
Page 49: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design
Page 50: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

IDEA

L FE

EDER

DES

IGN

IDEA

L FE

EDER

DES

IGN

For F

TTH

:

Whe

re to

pla

ce th

e op

tical

spl

itter

?

Page 51: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Whe

re s

houl

d th

e sp

litte

r be

plac

ed?

Dec

entr

aliz

ed/

Dis

trib

uted

Cen

tral

ized

Hom

e R

un

Page 52: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design
Page 53: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Whe

n to

pla

ce o

ptic

al

split

ters

in a

cab

inet

Econ

omic

Jus

tific

atio

n

Page 54: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Econ

omic

Rea

sons

to p

lace

a C

abin

et

Cen

tral

ized

Opt

ical

Lin

e C

ard

(OLT

)C

abin

et

Use

Effi

cien

tly

At w

hat

Cos

t?

Page 55: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

TAK

E R

ATE

D

EFIN

ITIO

N

20 H

OM

ES

O N T

O N T

O N TO N T

O N T

O N TO N T

O N T

O N TO N T

O N T

O N TO N T

O N T

O N T

O N T

ON

T O

N S

IDE

OF

HO

USE

15 H

OU

SE

S T

AK

E S

ER

VIC

E O

F S

OM

E T

YPE

TAK

E R

ATE

= 1

5 / 2

0 O

R

75%

TA

KE

RA

TE

Page 56: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

EL

ECTR

ONIC

S VE

RSUS

CEN

T. C

ABIN

ET C

OMPA

RISO

N

0 20

0 40

0 60

0 80

0 10

00

1200

14

00

1600

18

00

2000

22

00

2400

100

90

80

7

0

60

50

40

3

0

20

10

TAKE

RAT

E %

$ PER SUBSCRIBER

INCR

EMEN

TAL

ELEC

TRON

ICS

$/SUB

Page 57: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

EL

ECTR

ONICS

VERS

US CE

NT. C

ABINE

T COM

PARIS

ON

0

200

400

600

800

1000

1200

100

90

80

70

60

50

40

30

20

1

0 TA

KE RA

TE %

$ PER SUBSCRIBER

CENT

. CAB

INET

$/SUB

Page 58: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

ELEC

TRO

NIC

S VE

RSU

S C

ENT.

CA

BIN

ET C

OM

PAR

ISO

N

0

200

400

600

800

1000

1200

1400

1600

100

90

8

0

70

6

0

50

4

0

30

2

0

10

TAK

E R

ATE

%

$ PER SUBSCRIBER

INC

RE

ME

NTA

LE

LEC

TRO

NIC

S $

/SU

B

CE

NT.

CA

BIN

ET

$/S

UB

Whe

n to

use

spl

itter

cab

inet

s

Page 59: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

TAK

E R

ATE

100

90

8

0

70

60

50

40

3

0

20

HOUSING DENSITY

HIG

H

LOW

SPLI

TTER

S IN

CA

BIN

ETS

DISTANCE FROM HEADEND0 2 4 6 8 KFT

Econ

omic

Spl

itter

Loc

atio

n

Page 60: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Opt

ical

Spl

itter

s in

a

Cab

inet

or H

eade

nd/N

ode

Econ

omic

Jus

tific

atio

n

or

Page 61: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

3 O

ptio

ns fo

r Spl

itter

Pl

acem

ent:

6000�

2-1

44 f

iber c

ab

les

Bay t

o t

erm

inate

288 f

ibers

Ce

ntr

al O

ffic

e

6000

�1-12 f

iber c

able

1 s

helf t

o t

erm

inate

12 f

ibers

Ce

ntr

al O

ffic

e

288

hom

es

288

hom

es

Shelf w

ith 9

x32 s

plitte

rs

9-1x32 s

plitt

ers

Cent. C

abin

et

PL

AN

1-

CO

SP

LIT

TE

RS

PL

AN

2-

FIE

LD

SP

LIT

TE

RS

10

00

�1-12

fib

er ca

ble

1 she

lf to te

rm

inate

12

fib

ers

Ce

ntra

l O

ffic

e

288

hom

es

9-1

x3

2 sp

litters

In fie

ld in

d

ro

pclo

su

re

s

PL

AN

3-

FIE

LD

S

PL

IT

TE

RS

6000

Page 62: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

CO v

s. Ce

ntra

lized

Spl

itter

s

020406080100

1000

'

2

000'

300

0'

4000

'

5

000'

Dista

nce

to C

O

$/Sub

CO S

plitte

rCo

st

Cent

raliz

edCa

binet

Cost

CO

VS.

CA

BIN

ETS

Page 63: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

DIS

TAN

CE

TO C

O0

1

2

3

4

5

6

7

8KFT

SPLI

TTER

S IN

CA

BIN

ETS

SPLI

TTER

S IN

COC

O v

s. C

AB

INET

S

Valid

for t

ake

rate

s <5

0% o

nly

Valid

for t

ake

rate

s <5

0% o

nly

Page 64: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

TAK

E R

ATE

100

90

8

0

70

60

50

40

3

0

20

HOUSING DENSITY

HIG

H

LOW

SPLI

TTER

S IN

CA

BIN

ETS

DISTANCE FROM HEADEND0 2 4 6 8 KFT

SPLI

TTER

S IN

CO

Econ

omic

Spl

itter

Loc

atio

n

Page 65: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Opt

ical

Spl

itter

s in

a

Cab

inet

/Hea

dend

/Nod

e

or D

istr

ibut

ed

Econ

omic

Jus

tific

atio

n

or

Page 66: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Rug

gedi

zed

PLC

Spl

itter

in

Clo

sure

Prot

ects

Spl

itter

for d

urab

ility

and

fie

ld h

andl

ing

Clo

sure

Tra

ys

This

hol

der d

esig

ned

to h

old

split

ters

Clo

sure

A

ssem

bly

Pack

aged

PLC

split

ter

with

robu

st fi

ber c

orda

gehe

lps p

reve

nt d

amag

e du

ring

inst

alla

tion

Page 67: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

CO

NF

ID

EN

TIA

L

DO

NO

T D

IS

TR

IB

UT

E O

R D

UPLIC

AT

EPR

OPE

RT

Y O

F B

UC

KE

YE

CA

BLE

VIS

IO

N I

NC.

AN

D P

RO

PR

IE

TA

RY

DIS

TRIB

UTE

D S

PLIT

TIN

G

DES

IGN

STEP

:D

EFIN

EPO

N A

REA

S

Page 68: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

CO

NF

ID

EN

TIA

L

DO

NO

T D

IS

TR

IBU

TE O

R D

UPLICA

TE

PRO

PER

TY

OF

BU

CK

EY

E C

ABLEV

IS

IO

N I

NC.

AN

D P

RO

PR

IE

TA

RY

STEP

:D

ETER

MIN

ESP

LITT

ER

LOC

ATI

ON

S

Page 69: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

CO

NF

ID

EN

TIA

L

DO

NO

T D

IS

TR

IB

UT

E O

R D

UPLICA

TE

PR

OPE

RT

Y O

F B

UCKE

YE

CA

BLEV

IS

IO

N I

NC.

AN

D P

RO

PR

IE

TA

RY

STEP

:D

ETER

MIN

EFI

BER

CA

BLE

RO

UTE

S A

ND

SI

ZES

Page 70: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

60

00

�2-1

44 f

ibe

r ca

ble

s

Ba

y t

o t

erm

inate

28

8 f

ibe

rs

Ce

ntr

al O

ffic

e

600

0�

1-1

2 f

ibe

r ca

ble

1 s

helf t

o t

erm

ina

te12

fib

ers

Ce

ntr

al O

ffic

e

28

8h

om

es

28

8h

om

es

Sh

elf w

ith 9

1x32

sp

litte

rs

9-1

x32

sp

litte

rsC

en

t. C

ab

inet

PL

AN

1-

CO

SP

LIT

TE

RS

PL

AN

2-

FIE

LD

SP

LIT

TE

RS

100

0�

1-1

2 f

ibe

r ca

ble

1 s

helf t

o t

erm

inate

12

fib

ers

Cen

tra

l O

ffic

e

288

hom

es

9-1

x32

sp

litte

rsIn

fie

ld in d

rop

clo

sure

s

PL

AN

3-

FIE

LD

SP

LIT

TE

RS

CO

vs.

SPL

ITTE

RS

INEA

CH

PO

N

(DIS

TRIB

UTE

D)

Page 71: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

DIS

TAN

CE

TO C

O0

1

2

3

4

5

6

7

8KFT

SPLI

TTER

S IN

EAC

H P

ON

Valid

for t

ake

rate

s >5

0% o

nly

Valid

for t

ake

rate

s >5

0% o

nly

CO

vs.

SPL

ITTE

RS

INEA

CH

PO

N

Page 72: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

ELEC

TRON

ICS

VERS

US C

ENT.

CAB

INET

COM

PARI

SON

0

200

400

600

800

1000

1200

1400

1600

100

9

0

8

0

70

60

50

40

30

20

10

TAKE

RAT

E %

$ PER SUBSCRIBER

INCR

EMEN

TAL

ELEC

TRON

ICS

$/SUB

CENT

. CAB

INET

$/SUB

Page 73: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

TAK

E R

ATE

100

90

8

0

70

60

50

40

3

0

20

HOUSING DENSITY

HIG

H

LOW

SPLI

TTER

S IN

CA

BIN

ETS

SPLI

TTER

S IN

EAC

H P

ON

DISTANCE FROM HEADEND0 2 4 6 8 KFT

SPLI

TTER

S IN

CO

Econ

omic

Spl

itter

Loc

atio

n

Page 74: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Ope

ratio

nal C

once

rns:

13

2R

elia

bilit

y

12

2Tr

oubl

esho

ot

12

2N

ew In

stal

l

32

1U

pgra

de

Dis

tribu

ted

Cen

traliz

edH

ome

Run

Issu

e

Page 75: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

DAP

Des

ign

(insi

de 3

2 ho

me

PON

are

a)

2 fa

ctor

s af

fect

2 fa

ctor

s af

fect

Fund

amen

tal D

esig

nFu

ndam

enta

l Des

ign

insi

de th

e PO

N A

rea:

insi

de th

e PO

N A

rea:

Labo

r Rat

eLa

bor R

ate

Den

sity

Den

sity

Page 76: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

PON

Des

ign

(insi

de 3

2 ho

me

PON

are

a) Labo

r Rat

e:

Cos

t Mod

el S

tudi

ed a

ll va

riatio

ns

Page 77: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Con

clus

ion:

Con

vent

iona

l Des

ign

is th

e m

ost e

cono

mic

al

whe

n fu

sion

spl

icin

g is

use

d up

to a

labo

r rat

e of

$65

-75/

hr

PO

N C

ab

ling

Dro

p C

on

ne

cto

rs V

ers

us

Fu

sio

n S

plic

ing

$6

5/H

R

0

50100

150

200

250

300

Fu

sio

n S

plic

ed

$65

/HR

Co

nn

ect

ors

on

Dro

p

$/SUBSCRIBER

Conve

ntional

Direct

Feed

Direct-

Mid

Split

Splic

ed

Splic

ed-

Double

Splic

ed-

Quad

Labo

r Rat

e An

alys

is

Page 78: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

How

doe

s H

ow d

oes

Hou

sing

Den

sity

affe

ctH

ousi

ng D

ensi

ty a

ffect

Des

ign?

Des

ign?

PON

Des

ign

(insi

de 3

2 ho

me

PON

are

a)

Page 79: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Hou

sing

Den

sity

:

Mos

t Den

se:

Mos

t Den

se:

Apa

rtm

ents

Apa

rtm

ents

Hig

h R

ises

Hig

h R

ises

Leas

t Den

se: R

ural

Le

ast D

ense

: Rur

al

Are

asA

reas

Nor

mal

Den

sity

:N

orm

al D

ensi

ty:

Subd

ivis

ions

Subd

ivis

ions

Page 80: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Hou

sing

Den

sity

:

Hig

h R

ises

Hig

h R

ises

Page 81: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

FDH

Hig

h R

ise

PON

: A

ggre

gatio

n A

rchi

tect

ure

OSP

C

losu

re

Cei

ling Fl

oor

Term

inal

FDH

Adva

ntag

es o

ver c

onve

ntio

nal

cabl

ing:

�M

inim

izes

impa

ct o

n ris

er s

pace

�Ins

talls

ver

y qu

ickl

y

Four

Com

pone

nts:

�FD

H�C

ombi

ner

�Ter

min

al�D

rop

Cab

le

Dro

pO

NT

Com

bine

r

Ris

er

Cab

le

Page 82: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Hou

sing

Den

sity

:

Mul

tiM

ulti --

Dw

ellin

gD

wel

ling

Uni

ts (

MD

U)

Uni

ts (

MD

U)

(cam

pus

(cam

pus --

styl

est

yle

apar

tmen

ts)

apar

tmen

ts)

Page 83: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design
Page 84: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

DE

DIC

ATE

D C

AB

LE T

O E

AC

H B

UIL

DIN

G

LOO

PE

D C

AB

LE T

O E

AC

H B

UIL

DIN

G

IDEA

L M

DU

DEV

ELO

PMEN

T

Page 85: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

TRU

CK

RO

LL C

OST

VER

SUS

ELEC

TRO

NIC

S IN

CR

EMEN

TAL

CO

ST

0

200

400

600

100

90

80

70

60

50

40

30

20

10

TU

RN

OVE

R %

$ PER SUBSCRIBER

AD

D'L

ELE

CTR

ON

ICS

$/SU

B

TRU

CK

RO

LL

Page 86: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

MD

U C

ON

CLU

SIO

NS

MD

U C

ON

CLU

SIO

NS

1.1.TH

E M

OST

EC

ON

OM

ICAL

PLA

N IS

TO

LO

OP

THE

CA

BLE

TH

E M

OST

EC

ON

OM

ICAL

PLA

N IS

TO

LO

OP

THE

CA

BLE

B

ETW

EEN

BU

ILD

ING

S W

ITH

A 1

X32

FEED

ING

TH

E B

UIL

DIN

GS.

B

ETW

EEN

BU

ILD

ING

S W

ITH

A 1

X32

FEED

ING

TH

E B

UIL

DIN

GS.

2. IF

LO

OPI

NG

TH

E C

AB

LE IS

IMPR

AC

TIC

AL,

TH

E SE

CO

ND

BES

T2.

IF L

OO

PIN

G T

HE

CA

BLE

IS IM

PRA

CTI

CA

L, T

HE

SEC

ON

D B

EST

PLA

N IS

WIT

H D

EDIC

ATED

CA

BLE

S SE

RVE

D

PLA

N IS

WIT

H D

EDIC

ATED

CA

BLE

S SE

RVE

D

FRO

M A

1X3

2 SP

LITT

ERFR

OM

A 1

X32

SPLI

TTER

3. D

ISTA

NC

E IS

SLI

GH

TLY

SEN

SITI

VE T

O S

ELEC

TIN

G3.

DIS

TAN

CE

IS S

LIG

HTL

Y SE

NSI

TIVE

TO

SEL

ECTI

NG

AN

APP

RO

PRIA

TE D

ESIG

N P

LAN

AN

APP

RO

PRIA

TE D

ESIG

N P

LAN

4. B

UIL

DIN

G S

IZE

IS S

LIG

HTL

Y SE

NSI

TIVE

TO

SEL

ECTI

NG

4.

BU

ILD

ING

SIZ

E IS

SLI

GH

TLY

SEN

SITI

VE T

O S

ELEC

TIN

G

AN

APP

RO

PRIA

TE D

ESIG

N P

LAN

AN

APP

RO

PRIA

TE D

ESIG

N P

LAN

Page 87: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Hou

sing

Den

sity

: Nor

mal

Den

sity

:N

orm

al D

ensi

ty:

Subd

ivis

ions

Subd

ivis

ions

Page 88: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

PON

Des

ign

(insi

de 3

2 ho

me

PON

are

a)

Cos

t Mod

el S

tudi

ed a

ll va

riatio

ns

Page 89: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Con

clus

ion:

Con

vent

iona

l Des

ign

is th

e m

ost e

cono

mic

al

For a

ll SF

R d

ensi

ties

PO

N C

ab

ling

ba

se

d o

n lo

t s

ize

0

50

100

150

200

250

300

350

400

50'

Lo

ts

100'

200'

4

00'

$/SUBSCRIBER

Conve

ntional

Direct

Feed

Direct-

Mid

Split

Splic

ed

Splic

ed-

Double

Splic

ed-

Quad

Sing

le F

amily

Res

iden

tial A

reas

-Urb

an/S

ubur

ban

Page 90: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

1 2 3 4 8765 1211109 19 20 21 2215 16 17 181413 2423

BLUE ORANGE

Dis

trib

utio

n D

esig

n Te

chni

que-

Dis

trib

uted

Spl

ittin

g

Page 91: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Hou

sing

Den

sity

:

Leas

t Den

se:

Leas

t Den

se:

Rur

al A

reas

Rur

al A

reas

Page 92: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

1x32

1x4 1x

81x

81x

81x

8

24 fi

ber

12 fi

ber

Opt

ical

Spl

itter

Opt

ions

1x4

1x8

12 fi

ber

1x4

1x4

1x4

1x4

1x4

1x4

1x4

1x2

1x16

12 fi

ber

1x2

1x2

1x2

1x2

1x2

1x2

1x2

1x32

Page 93: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Whe

n to

dist

ribut

e spl

itter

s

0

1000

2000

3000

4000

5000

6000

7000

0

1

3

5

7

9

11

PON

DIST

ANCE

IN K

FT

TOTAL COST

1X32

SPLI

TTE R

1X4/

1X8 SP

LITT

E R

Page 94: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

41 2 3 4

85 6 7 8

4321

88

5 6 7 8

4321

88

5 6 7 8

4321

8

85 6 7 8

4321

8

Rur

al A

rea

Dis

trib

uted

Spl

ittin

g Te

chni

que

Page 95: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

RU

RA

L A

REA

TAK

E R

ATE

100

90

8

0

70

60

50

40

3

0

20

10

HOUSING DENSITYH

IGH

LOW

SPLI

TTER

S IN

CA

BIN

ETS

SPLI

TTER

S IN

EAC

H P

ON

DISTANCE FROM HEADEND0 2 4 6 8 KFT

SPLI

TTER

S IN

CO

Econ

omic

al S

plitt

er L

ocat

ion

Page 96: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

PON

cab

le d

esig

nPO

N c

able

des

ign

PON

Des

ign

(insi

de 3

2 ho

me

PON

are

a)

Page 97: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Fibe

r Dro

p D

esig

n:

1.1.D

esig

n fo

r abo

ut 8

dro

ps p

er c

losu

reD

esig

n fo

r abo

ut 8

dro

ps p

er c

losu

re

2.2.U

se 2

fibe

r dro

p to

hav

e a

spar

e fib

er

Use

2 fi

ber d

rop

to h

ave

a sp

are

fiber

av

aila

ble

avai

labl

e

Page 98: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Fund

amen

tal P

lann

ing

and

Des

ign

Less

ens

Lear

ned:

1.H

ave

a lo

ng ra

nge

plan

to fo

llow

to m

ake

sure

all t

he p

iece

s fit

toge

ther

in th

e en

d

2. M

anag

e bu

dget

s ov

er th

e ye

ars

to m

eet t

arge

ted

build

dat

es

3. P

rope

r cab

le s

izin

g fo

r the

ent

ire n

etw

ork

4. P

lan

appr

oval

up

fron

t str

eam

lines

app

rova

l pro

cess

Page 99: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Des

ign

Dec

isio

n

Flow

Cha

rt

PON

< 500

0'

Yes

No

1x32

Spli

tters

in 25

6 hom

e

cabin

ets

1x4/8

Dist

ribut

ed

Spli

tting

Labo

r Rate

< $7

5

Yes

No

Co

nven

tiona

l

D

esign

Fusio

n Spli

ce D

rops

Conn

ecto

rized

Dro

p

Des

ign

Co

nven

tiona

l

D

esign

Fusio

n Spli

ce D

rop s

Custo

mers

>40

00' fr

om C

O

or no

de

Yes

No

Splitt

ers in

CO or

node

1 Fibe

r to e

ach

un

it fro

m

CO or

node

Splitt

ers in

CO or

node

1 Fibe

r to e

ach

unit

in to

wmfro

m CO

or no

de

Inside

Small

Town

sOp

tiona

l

Take

Rate

>50%

Yes

No

Hous

ing D

ensit

y

Multi-

Dwell

ingSI

ngle

Fami

ly

HIgh

Rise

Camp

us St

yle

Verti

cal q

uick

conn

ect d

esign

loo

p cab

le D

istrib

ute

Splitt

ers

PON

< 500

0'

Yes

No

1x32

Dist

ribut

ed

Spli

tting

1x4/8

Dist

ribute

d

Spli

tting

Labo

r Rate

< $7

5

Yes

No

Co

nven

tiona

l

D

esign

Fusio

n Spli

ce D

rops

Conn

ecto

rized

Dro

p

Des

ign

Hous

ing D

ensit

y

Multi-

Dwell

ingSI

ngle

Fami

ly

HIgh

Rise

Camp

us St

yle

Verti

cal q

uick

conn

ect d

esign

Splitt

ers in

cabin

et or

onsit

e nod

e

1 Fibe

r to e

ach

un

it fro

mca

binet

or no

de

Co

nven

tiona

l

D

esign

Fusio

n Spli

ce D

rops

Page 100: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

FTTH

AC

TUA

LFT

TH A

CTU

AL

EX

AM

PLE

SE

XA

MP

LES

Page 101: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

32

32

19

16

32

32

3264

31

29

64

32

19

64

31

12

32

32

S

S

S

S

S

S

SS

SS

S

S

S

S

S

S

350'12 fiber

2200'24 fiber

2700'24 fiber

1400'36 fiber

450'12 fiber SS

600'24 fiber

900'36 fiber

120'12 fiber

1300'24 fiber

300'24 fiber

1200'36 fiber

1550'36 fiber

1500'36 fiber

600'12 fiber

1250'24 fiber

1700'24 fiber

1300'36 fiber

175'12 fiber

300'12 fiber

650'12 fiber

700'24 fiber

900'12 fiber

1750'24 fiber

27

700'12 fiber

1200'24 fiber

1550'24 fiber

1500'24 fiber

2350'24 fiber

1000'24 fiber

1100'36 fiber

3200'36 fiber

To H

eade

nd/C

O

Page 102: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Fibe

r Cab

le:

Plan

ning

Size

Am

ount

Ord

er C

ode

Desc

riptio

nPr

ice

Cos

t12

FIB

ER42

45A

T-3B

E12Y

T-01

2SI

NG

LE J

ACK

ET-D

CM

_12F

A W

_.3

5/.2

5@13

10/1

550

0.20

7$8

7924

FIB

ER20

100

AT-

3BE1

2YT-

024

SIN

GLE

JAC

KET

-DC

M_2

4F A

W _

.35/

.25@

1310

/155

00.

284

$5,7

0836

FIB

ER12

150

AT-

3BE1

2YT-

036

SIN

GLE

JAC

KET

-DC

M_3

6F A

W _

.35/

.25@

1310

/155

00.

35$4

,253

1x32

Opt

ical

Spl

itter

1830

0524

378

R1-

1X32

-FU

LL-U

NC

-00-

BAL

700

1260

0

CLO

SUR

ES12

6TY

CO

450

A O

R E

QU

IVAL

ENT

150

1890

0

tota

l$4

2,34

0

Cos

t per

hom

e pa

ssed

:$7

7

Fibe

r Dro

p83

000

AT-3

BE8T

7X-0

022

Fibe

r fla

t dro

p0.

14$1

1,62

0

Gra

nd T

otal

:$5

3,96

0C

ost p

er h

ome

pass

ed in

clud

ing

drop

:$9

8.29

Page 103: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

30

32

32

32

32 32

32

8

9

32

32

32

32

32

18

00'

24

F

IB

ER

CA

BL

E

24

FIB

ER

CA

BL

E

12

00'

24 F

IB

ER

CA

BL

E

275

0'

24

FIB

ER

CA

BL

E

900

'2

4 F

IB

ER

CA

BL

E

65

0'

12

F

IB

ER

CA

BL

E

25

00'

36 F

IB

EC

AB

LE

25

0'

12

F

IB

ER

CA

BL

E

275

'12

F

IB

ER

CA

BL

E

95'

12 F

IB

ER

CA

BL

E

36 F

IB

ER

CA

BL

E

36 F

IB

CA

BL

36

F

IB

ER

CA

BL

E

36

F

IB

ER

CA

BL

E

23

00'

24

F

IB

ER

CA

BL

E

20

00'

24

F

IB

ER

CA

BL

E31

00'

36

F

IB

ER

CA

BL

E

Page 104: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

323livi

ng uni

ts

AMOU

NTPar

t#

Descr

iption

$/unit

cost

12 FIB

ER217

0AT

-3BEH

2YT-01

2LIG

HT AR

MOR_

12F A W

_.35/.2

5@131

0/1550

0.32

69424

FIBER

10476

AT-3B

EH2YT

-024

LIG

HT AR

MOR_

24F A W

_.35/.2

5@131

0/1550

0.38

3,981

36 FIB

ER710

0AT

-3BEH

2YT-03

6LIG

HT AR

MOR_

36F A W

_.35/.2

5@131

0/1550

0.44

3,124

144 FIB

ER260

0AT

-3BEH

2YT-14

4LIG

HT AR

MOR_

144F A

W _.3

5/.25@

1310/1

5501.3

3,380

32 SP

LITTE

R11

300524

378Ru

ggediz

ed 1x3

2 optic

al split

ter675

7,425

CL

OSUR

ES73

TYCO

450A

OR EQ

UIVAL

ENT

15010,

950

total

$29,70

4PR

ICES A

REFO

R PLA

NNING

PURP

OSES

ONLY

Cost p

er hom

epass

ed =

$92

Page 105: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design
Page 106: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

738

living

units

AM

OUNT

Part#

De

script

ion$/u

nitco

st12

FIBE

R18

00AT

-3BE1

2YT-0

12

SINGL

E JAC

KET-D

CM_1

2F A

W _.3

5/.25

@131

0/155

00.2

341

424

FIBE

R13

400

AT-3B

E12Y

T-024

SIN

GLE J

ACKE

T-DCM

_24F

A W

_.35/.

25@1

310/1

550

0.29

3,886

36 FI

BER

5500

AT-3B

E12Y

T-036

SINGL

E JAC

KET-D

CM_3

6F A

W _.3

5/.25

@131

0/155

00.3

72,0

3548

FIBE

R12

00AT

-3BEH

2YT-0

48SIN

GLE J

ACKE

T-DCM

_48F

A W

_.35/.

25@1

310/1

550

0.47

564

1x32

splitt

er24

3005

2437

8Ru

gged

ized 1

x32 o

ptica

l spli

tter

675

16,20

0

CL

OSUR

ES10

0TY

CO 45

0A OR

EQUIV

ALEN

T12

512

,500

total

$35,59

9PR

ICES A

REFO

R PL

ANNIN

GPU

RPOS

ES ON

LY

Cost

per h

omep

asse

d =$4

8

FIB

ER DR

OP738

00AT

-3BE8

T7X-0

02 M

ini LT

2 fib

er Fla

t drop

cable

0.14

$10,33

2No

te: Dr

op ca

lculate

d at 1

00' pe

r living

unit

Total

Cost

Per H

ome P

assed

= $62

Page 107: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

CONF

IDEN

TIAL

DO N

OT D

ISTR

IBUT

E O

R DU

PLIC

ATE

PRO

PERT

Y O

F BU

CKEY

E CA

BLEV

ISIO

N IN

C.

AND

PROP

RIET

ARY

CONF

IDEN

TIAL

DO N

OT D

ISTR

IBUT

E OR

DUP

LICA

TEPR

OPER

TY O

F BU

CKEY

E CA

BLEV

ISIO

N IN

C.

AND

PROP

RIET

ARY

Mat

eria

l co

st

Per

hom

e pa

ssed

=

$86

Mat

eria

l co

st

Per

hom

e pa

ssed

=

$146

Page 108: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design
Page 109: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

ALC

AL

U T

RIA

L24

5liv

ing

units

DIS

TRIB

UTE

D S

PLI

TTIN

GP

LAN

(met

ers)

$/

mtr

)A

MO

UN

TP

art#

D

escr

iptio

n$/

unit

cost

12 F

IBE

R50

AT-

3BE

12Y

T-01

2

SIN

GLE

JA

CK

ET-

DC

M_1

2F A

W _

.35/

.25@

1310

/155

00.

5900

3024

FIB

ER

5080

AT-

3BE

12Y

T-02

4

SIN

GLE

JA

CK

ET-

DC

M_2

4F A

W _

.35/

.25@

1310

/155

00.

7200

3,65

851

301x

32 s

plitt

er8

3005

2437

8R

1-1X

32-F

ULL

-UN

C-0

0-B

AL

650

5,20

0

CLO

SU

RE

S48

TYC

O 4

50A

OR

EQ

UIV

ALE

NT

125

6,00

0

tota

l$1

5,03

7P

RIC

ES

AR

EFO

R

PLA

NN

ING

PU

RP

OS

ES

ON

LY

Cos

t per

hom

epa

ssed

=$6

1

FIB

ER

DR

OP

1470

0A

T-3B

E8T

7X-0

02 M

ini L

T 2

fiber

Fla

t dro

p ca

ble

0.47

$6,9

09(D

ISTA

NC

E C

ALC

ULA

TED

AT

60m

PE

R H

OM

E P

AS

SE

D)

Tota

l Cos

t Per

Hom

e P

asse

d =

$90

SP

LITT

ER

CA

BIN

ET

Not

e: w

hen

com

pari

ng c

osts

, add

spl

icin

g co

st fo

r 84

add

ition

al s

plic

esP

LAN

(met

ers)

$/

mtr

)A

MO

UN

TP

art#

D

escr

iptio

n$/

unit

cost

12 F

IBE

R50

AT-

3BE

12Y

T-01

2

SIN

GLE

JA

CK

ET-

DC

M_1

2F A

W _

.35/

.25@

1310

/155

00.

5900

30

36 F

IBE

R24

80A

T-3B

EH

2YT-

036

SIN

GLE

JA

CK

ET-

DC

M_3

6F A

W _

.35/

.25@

1310

/155

00.

7200

1,78

6

72 F

IBE

R17

00A

T-3B

EH

2YT-

072

SIN

GLE

JA

CK

ET-

DC

M_7

2F A

W _

.35/

.25@

1310

/155

01.

5500

2,63

519

2 FI

BE

R90

0A

T-3B

EH

2YT-

192

SIN

GLE

JA

CK

ET-

DC

M_1

92F

A W

_.3

5/.2

5@13

10/1

550

3.93

003,

537

28

8 O

rbita

l Cab

inet

130

0530

565

Orb

ital2

88-S

CA

-01-

06-1

2YT-

2/14

4-10

0F60

006,

000

1x32

spl

itter

830

0505

856

S1-

1X32

-FU

LL-M

PO

/SC

A-S

-BA

L-F

700

5,60

0

MP

O J

umpe

rs32

3005

4302

2M

PO

8UA

PC

/SC

AP

C-L

L/TC

F-H

Z001

-0.7

8M15

04,

800

Not

e: r

/w c

ost,

conc

tret

e pa

d an

d co

ndui

t cos

t not

incl

uded

in th

is a

mou

nt fo

r ca

bine

t

CLO

SU

RE

S48

TYC

O 4

50A

OR

EQ

UIV

ALE

NT

125

6,00

0

tota

l$3

0,38

7P

RIC

ES

AR

EFO

R

PLA

NN

ING

PU

RP

OS

ES

ON

LY

Cos

t per

hom

epa

ssed

=$1

24

FIB

ER

DR

OP

1470

0A

T-3B

E8T

7X-0

02 M

ini L

T 2

fiber

Fla

t dro

p ca

ble

0.47

$6,9

09(D

ISTA

NC

E C

ALC

ULA

TED

AT

60m

PE

R H

OM

E P

AS

SE

D)

Tota

l Cos

t Per

Hom

e P

asse

d =

$152

Page 110: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design
Page 111: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design
Page 112: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

A

MO

UN

TPa

rt#

D

escr

iptio

n$/

unit

cost

12 F

IBER

(Min

i LT)

5420

0A

T-3B

E8T7

X-01

2

Min

i LT

12 fi

ber F

lat d

rop

cabl

e0.

2111

,382

1x4

s plit

ter

41x

4 op

tical

spl

itter

150

600

1x8

split

ter

141x

8 op

tical

spl

itter

250

3,50

0

C

LOSU

RES

26C

oyot

e In

-Lin

e R

unt o

r equ

ival

ent

100

2,60

0

tota

l$6

,850

PRIC

ES A

RE

FOR

PL

AN

NIN

GPU

RPO

SES

ON

LY

Cos

t per

hom

epa

ssed

=$6

9

FI

BER

DR

OP

2970

0A

T-3B

E8T7

X-00

2 M

ini L

T 2

fiber

Fla

t dro

p ca

ble

0.14

$4,1

58N

ote:

300

' per

hom

e pa

ssed

ass

umed

for d

rop

leng

thTo

tal C

ost P

er H

ome

Pass

ed =

$1

11

Han

cock

Tel

99liv

ing

units

Hom

e R

un fr

om R

emot

e

AM

OU

NT

Part

#

Des

crip

tion

$/un

itco

st12

FIB

ER15

400

AT-

3BE8

T7X-

012

M

ini L

T 12

fibe

r Fla

t dro

p ca

ble

0.21

3,23

4

36 F

IBER

9100

AT-

3BE1

2YT-

036

SI

NG

LE J

ACK

ET-D

CM

_36F

A W

_.3

5/.2

5@13

10/1

550

0.29

2,63

9

60 F

IBER

1700

0A

T-3B

E12Y

T-06

0

SIN

GLE

JAC

KET

-DC

M_6

0F A

W _

.35/

.25@

1310

/155

00.

46,

800

72 F

IBER

1270

0A

T-3B

E12Y

T-07

2

SIN

GLE

JAC

KET

-DC

M_7

2F A

W _

.35/

.25@

1310

/155

00.

486,

096

Fi

ber S

helv

es2

LPS1

-A-S

CA

UNC

-BR

-072

-07-

50F

72 p

ort t

erm

inat

ion

shel

f15

003,

000

Fibe

r jum

pers

99A

llwav

e A

dvan

tage

MW

1LC

-SC

-20

Fibe

r jum

pers

from

spl

itter

to s

helf

151,

485

1x32

spl

itter

430

0524

378

Rug

gedi

zed

1x32

opt

ical

spl

itter

700

2,80

0

C

LOSU

RES

26TY

CO

450

A O

R E

QU

IVA

LEN

T10

02,

600

tota

l$2

5,42

0PR

ICES

AR

EFO

R

PLA

NN

ING

PUR

POSE

S O

NLY

Cos

t per

hom

epa

ssed

=$2

57

FI

BER

DR

OP

2970

0A

T-3B

E8T7

X-00

2 M

ini L

T 2

fiber

Fla

t dro

p ca

ble

0.14

$4,1

58N

ote:

300

' per

hom

e pa

ssed

ass

umed

for d

rop

leng

thTo

tal C

ost P

er H

ome

Pass

ed =

$2

99

Page 113: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

IDEA

L FE

EDER

DES

IGN

IDEA

L FE

EDER

DES

IGN

Des

ign

tips

to s

ave

Des

ign

tips

to s

ave

splic

ing

time

splic

ing

time

Page 114: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

FIB

ER C

AB

LE T

APE

RIN

GFI

BER

CA

BLE

TA

PER

ING

CO

OR

HE

9672

6048

24

9696X

XX

X

CO

OR

HE

9672

48

96

96X

XX

4840

W

OR

KIN

G

30 W

OR

KIN

G

ELIM

INA

TE U

NEC

ON

OM

ICA

L TA

PER

S

SIZE

CA

BLE

TO

RED

UC

E SP

LIC

ING

Page 115: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design
Page 116: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design
Page 117: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design
Page 118: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

How

muc

h ba

ndw

idth

will

be n

eede

d in

the

futu

re?

Page 119: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design
Page 120: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design
Page 121: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Full

Spec

trum

Ena

bled

: Zer

o W

ater

Pea

k

Page 122: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Tech

nolo

gy R

oadm

ap:

Full

Spec

trum

-CW

DM

Wav

elen

gth

Lege

nd fo

r Upg

rade

O

ptio

ns12

7112

9113

1113

3113

5113

7113

9114

1114

3114

5114

7114

9115

1115

3115

5015

7115

9116

11

O1

O2

O3

O4

O5

E1 E2 E3 E4 E5 S1 S2 S3 C1

C2 L1 L2 L3

λ1 λ2 λ3 λ4 λ5 λ6 λ7 λ8 λ9 λ10

λ11

λ12

λ13

λ14

λRF

λ15

λ16

CW

DM

Ful

l Spe

ctru

m W

avel

engt

h gr

id

�ITU

G.6

94.2

(127

1 �

1611

nm

)

�18

wav

elen

gths

�20

nm s

paci

ng b

etw

een

wav

elen

gths

Page 123: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design
Page 124: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

high

pur

ity s

ynth

etic

sili

ca:

�No

risk

of lo

ng w

avel

engt

h hy

drog

en a

ging

loss

�Min

imiz

es d

egra

datio

n of

stre

ngth

and

bre

ak

frequ

ency

Figu

re 1

.H

igh

purit

y sy

nthe

tic s

ilica

fibe

r.

Figu

re 2

. Che

ap n

atur

al q

uart

z ra

w m

ater

ialf

iber

cl

early

sho

ws

man

y pi

ts a

nd im

perfe

ctio

ns .

�Acn

e lik

e�co

nditi

on s

how

s di

ffere

nce

betw

een

pure

and

cle

an s

ynth

etic

qua

rtz

vsna

tura

l qua

rtz

with

its

impu

ritie

s an

d in

clus

ions

.

Figu

res

1 an

d 2

show

SE

M m

icro

grap

hs o

f fib

er e

nd-

face

s. I

n bo

th c

ases

the

cle

aved

fibe

r sur

face

was

br

iefly

etc

hed

in a

cid

(48%

HF

for 3

min

utes

).S

EM

mic

rogr

aphs

take

n by

OFS

.

Nat

ural

Qua

rtz

raw

mat

eria

l:�A

lkal

i im

purit

ies

can

lead

to lo

ng w

avel

engt

h hy

drog

en a

ging

loss

�Par

ticul

ate

incl

usio

nsca

n le

ad to

deg

rada

tion

of s

treng

th a

nd in

crea

sed

brea

k fre

quen

cy

Stab

le R

elia

ble

Perf

orm

ance

nee

ded

for F

TTX

Page 125: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

FTTH

Des

igne

rFT

TH D

esig

ner

Page 126: TT09_DAY2_CCTA_Fundamental FTTH Planing and Design

Dav

id S

tallw

orth

dsta

llwor

th@

ofso

ptic

s.co

m

770-

798-

2423

Than

k Yo

u!