TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside...

60
M32930 69-2413EF-05 TrueEASE™ Humidification System PROFESSIONAL INSTALLATION GUIDE INCLUDED IN THIS HUMIDIFIER BOX Tools needed to install humidifier Wire cutter/stripper Tin snips or sheet metal cutter #8 hex nut driver Standard screwdriver 18-gauge wire (up to 5 conductor) Other Requirements If floor drain is not available, refer to Appendix B for additional plumbing parts consideration. If installed in or above a finished space, Honeywell recommends installing a drip pan with water sensor shut-off. A1 Humidifier Bypass A2 Humidifier Fan Saddle valve Water supply line Drain hose (10 feet) E Owner’s manual F Mounting template G H8908 manual humidity control Hardware (not pictured) Additional accessories included in select models E A1 A2 F G GETTING STARTED MOUNTING PLUMBING WIRING APPENDICES OPERATION AND SERVICE Cross Reference Table Humidifier Honeywell® Aprilaire® GeneralAire® HE100 and HE150 HE225 500 570 HE200 and HE250 HE265 600 900 HE300 HE365 700 1000

Transcript of TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside...

Page 1: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

M32930

69-2413EF-05

TrueEASE™ Humidification SystemPROFESSIONAL INSTALLATION GUIDE

INCLUDED IN THIS HUMIDIFIER BOX

Tools needed to install humidifier Wire cutter/stripper

Tin snips or sheet metal cutter

#8 hex nut driver

Standard screwdriver

18-gauge wire (up to 5 conductor)

Other Requirements

If floor drain is not available, refer to Appendix B for additional plumbing parts consideration.

If installed in or above a finished space, Honeywell recommends installing a drip pan with water sensor shut-off.

A1 Humidifier BypassA2 Humidifier Fan

Saddle valve

Water supply line

Drain hose (10 feet)E Owner’s manualF Mounting templateG H8908 manual humidity control

Hardware (not pictured) Additional accessories included in select models

E

A1 A2

F G

GE

TT

ING

S

TAR

TE

DM

OU

NT

ING

PL

UM

BIN

GW

IRIN

GA

PP

EN

DIC

ES

OP

ER

AT

ION

A

ND

SE

RV

ICE

Cross Reference TableHumidifier Honeywell® Aprilaire® GeneralAire®

HE100 and HE150 HE225 500 570

HE200 and HE250 HE265 600 900

HE300 HE365 700 1000

Page 2: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models
Page 3: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

Humidifier

NEED HELP? For assistance with this product please visit http://yourhome.honeywell.com

or call Honeywell Customer Care toll-free at 1-800-468-1502.

Read and save these instructions.® U.S. Registered Trademark. Patents pending. Copyright © 2011 Honeywell International Inc. All rights reserved.

?

Humidifier 69-2413EF—05

GE

TT

ING

S

TAR

TE

DM

OU

NT

ING

PL

UM

BIN

GW

IRIN

GA

PP

EN

DIC

ES

OP

ER

AT

ION

A

ND

SE

RV

ICE

1

GETTING STARTED

Safety Definitions and Precautions . . . . . . . . . . . . . . 2

What to Expect From Your Humidifier . . . . . . . . . . . . 3

Important Installation Requirements . . . . . . . . . . . . . 4

MOUNTING

Choosing a Mounting Method . . . . . . . . . . . . . . . . . . 5

STEP ONE: Select the Mounting Location . . . . . . 6

STEP TWO: Install Mounting

Template to the Duct . . . . . . . . . . . . . . . . . . . . 6

Bypass Model Installation . . . . . . . . . . . . . . . . . . . . . 7

STEP THREE: Configure

Humidifier Bypass . . . . . . . . . . . . . . . . . . . . . . 7

STEP FOUR: Installation . . . . . . . . . . . . . . . . . . . 8

STEP FIVE: Bypass Duct Installation . . . . . . . . . . 9

Fan Model Installation . . . . . . . . . . . . . . . . . . . . . . . 10

STEP THREE: Installation . . . . . . . . . . . . . . . . . 10

Humidifier Control Installation . . . . . . . . . . . . . . . . . 11

OPTION ONE: Duct Installation

H8908 Humidistat . . . . . . . . . . . . . . . . . . . . . 11

OPTION TWO: Remote Installation

H8908 Humidistat . . . . . . . . . . . . . . . . . . . . . 12

PLUMBING

Water Supply and Drain Connections . . . . . . . . . . . 13

STEP ONE: Connect the Water Supply . . . . . . . 13

STEP TWO: Tap into a Water Line . . . . . . . . . . . 13

STEP THREE: Connect to the Water Drain . . . . 14

WIRING

Before Wiring Humidifier . . . . . . . . . . . . . . . . . . . . . 15

STEP ONE: Remove the Humidifier Cover . . . . 15

STEP TWO: Understand the Wiring Terminals . . 15

STEP THREE: Understand the DIP Switches . . 16

STEP FOUR: Install the Transformer

(Bypass Models Only) . . . . . . . . . . . . . . . . . . 16

STEP FIVE: Wiring Humidifier . . . . . . . . . . . . . . 16

Wiring Configuration: Advanced Models

(HE150/HE250/HE300) . . . . . . . . . . . . . . . . . . . . . . 17

Wiring Configuration: Basic Models

(HE100/HE200) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

OPERATION AND SERVICE

Startup and Checkout . . . . . . . . . . . . . . . . . . . . . . . 21

Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . 22

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

APPENDICES

A: Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

B: Advanced Draining . . . . . . . . . . . . . . . . . . . . . . . 25

C: Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Page 4: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

GE

TT

ING

S

TAR

TE

D

Safety Definitions and Precautions

Safety DefinitionsThese safety terms identify information you must read prior to installing or operating the humidifier.

CAUTION: Indicates a hazardous situation which, if not avoided, could cause bodily injury or property damage.

WARNING: Indicates a hazardous situation which, if not avoided, could result in death or serious injury.

Safety PrecautionsMake sure you read and understand the following safety hazards before installing, using, or working with the humidifier:

CAUTION: Voltage Hazard. Can cause electrical shock or equipment damage. Disconnect HVAC equipment and any electrical outlet being used for the humidifier installation.

WARNING: Electrocution and Water Hazard.Can cause death, blindness, and water damage to the home and HVAC Equipment.

CAUTION: Condensation, Fire, and Freezing Water Hazard. Can cause failure of fan or limit control or result in water damage to home.

Humidifier 69-2413EF—052

Page 5: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

GE

TT

ING

S

TAR

TE

D

The installer should review these points with the homeowner and answer any questions they have before leaving the job site.

• Achieving Humidity Setpoint. It may take up to a week of continuous operation to achieve the humidity setpoint, especially if the home is dry when the humidifier is installed. This also depends on such factors as weather, size of home, furnishings in the home, and insulation.

• Ideal Humidity. Home building industry experts cite 35% relative humidity as ideal for comfort and safeguarding the home during the typical dry season. Homeowners can adjust to their own comfort or until there is condensation on the windows. Lower the setpoint if condensation appears.

• Unit Not Humidifying. If the humidifier is not running but the humidity is below the setpoint, the humidity control may have a frost protection setting to prevent window condensation from appearing.

• Home Ventilation. Excessive ventilation sends moist air outside and replaces it with dry air. This can make it hard to maintain the humidity setpoint. If installing a ventilator, use a solution that retains moisture. An Energy Recovery Ventilator (ERV) is recommended.

• Cleaning Requirements. At least once per year it is recommended to change the humidifier pad and clean the water trays of the humidifier. See Operation and Service section for details.

• Energy Consumption. It is important to explain that with any humidification solution there is a cost associated with converting water to humidity. The humidifier utilizes the air heat and air flow in your ducting to make this conversion, which has gas and/or electric costs that depend on your HVAC system type and setup.

What to Expect From Your Humidifier

Humidifier 69-2413EF—05 3

Page 6: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

GE

TT

ING

S

TAR

TE

D

Personal Safety• Wear safety glasses while installing the humidifier.• Do not cut into any air conditioning or electrical line.• Follow professional safety standards and all local regulations for plumbing, electrical, and mechanical

considerations.

Mounting Location• Mount the humidifier in a level position to avoid water damage and ensure maximum output.• Location must have access to a water line, drain, and power.• Do not install the humidifier where the ambient temperature is lower than 34°F (1.1°C) or higher than 90°F

(40°C).• Mounting area must be strong enough to support humidifier weight (up to 16 lbs [Fan] or 10 lbs [Bypass]).• Do not mount directly to ductboard.• If used near a pool or spa, make sure the humidifier can not fall into the water or be splashed.• Ensure that the top and bottom covers of the humidifier can be removed and that the pad is accessible from

the chosen location.

Water Supply and Drainage• Consult local plumbing codes for drain size, material, and maximum temperature allowed.

If Replacing an Old Bypass Humidifier

The humidifier is not identical in size and shape to other Honeywell bypass humidifiers. Before performing a retrofit installation, you might need to:• Dry-fit the humidifier to the existing ducting, plumbing, and wiring before fastening it to the duct to ensure that

the existing connections will reach the humidifier.• If the duct opening of the old humidifier is not the right size for the humidifier, choose a new location or cover

the old opening with a piece of sheet metal and cut a new opening specifically for the humidifier using the template provided.

Important Installation Requirements

Failure to comply with these requirements will result in voided warranty, improper installation, and

service callbacks.

Cross Reference TableHumidifier Honeywell® Aprilaire® GeneralAire®

HE100 and HE150 HE225 500 570

HE200 and HE250 HE265 600 900

HE300 HE365 700 1000

Humidifier 69-2413EF—054

Page 7: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

MO

UN

TIN

G

Whether you purchased a Bypass or Fan humidifier will determine how your humidifier will be installed:

Which humidifier do you have?

Bypass:

Bypass humidifiers use the pressure difference between the supply and return to move duct air through the humidifier. Access to both the supply and return are required. The bypass humidifier can be positioned on either the supply or return duct.

MCR29871

Fan:

Fan humidifiers use the fan inside the humidifier to pull duct air through the humidifier. Honeywell strongly recomends mounting the HE300 on the supply duct for maximum humidification capacity. If a return duct installation is required, a trap must be installed in the drain line. A hard trap is recommended, but a coil in the line, secured with tape or zip tie, is also acceptable. See Water Supply and Drain Connections section for details.

MCR29929

Choosing a Mounting Method

Before beginning Mounting: I have confirmed local codes for proper plumbing practices. I have chosen an installation location that meets the requirements on page 4.

Humidifier 69-2413EF—05 5

Page 8: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

MO

UN

TIN

G

STEP ONE: Select the Mounting LocationChoose a location that has access to a water supply pipe. Cold or hot water can be used.

Select a vertical or horizontal surface on the HVAC duct work, with adequate space clearances, where the humidifier can be mounted.

Location must also have access to 120 VAC power. For the HE300 Fan humidifier, the power cord is 6 feet long.

Ensure the location is near a drain. Consult local plumbing codes for proper drainage. If no main floor drain is available, see “Appendix B: Advanced Draining.”

STEP TWO: Install Mounting Template to the Duct

Position the template on the duct. • Make sure the template is level and in the desired

position on the duct. Peel adhesive backing and press template firmly into place in desired mounting location.

Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models extend into the duct 1/2 inch. Ensure clearance inside the duct.• For best performance, maintain at least 24 inches

downstream of open air space inside the duct.

Cut the sheet metal, following the template outline.

MCR29877

M29873

1

M29874

A-COIL

1-3/4(44)

1/2(13)

FAN

BYPASS

4

2

2

3

3

2

1

M32930

Humidifier 69-2413EF—056

Page 9: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

MO

UN

TIN

G

STEP THREE: Configure Humidifier Bypass

Configure the humidifier bypass outlet to the side that best fits the application.

If the bypass needs to be on the other side, remove the top and bottom covers

Unplug the damper wire and plug in on the other side (HE150/HE250 only).

Pull the bypass clamps apart from center to remove the bypass; snap it back into place with the outlet on the desired side.

Ensure that the pad is accessible. The handle of the pad holder and side panel of the humidifier can be switched so the pad holder can be removed (opposite side of the bypass duct opening).

To remove the handle for the pad holder, slide it toward the back of the humidifier, then pull it away from the humidifier.

To remove the opposite side panel, place a screwdriver into the two slots on the back of the humidifier, and pop the panel off.

Snap the pad holder handle and side panel back into place in the desired configuration.

MCR29875

If you are installing HE300 Fan model, proceed to page 10.

Bypass Model Installation

MCR29876

1

1

2

2

3

3

MCR29946

4

5

Humidifier 69-2413EF—05 7

Page 10: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

MO

UN

TIN

G

STEP FOUR: Mounting

Secure the support hooks on Bypass models to the bottom lip of the hole.

Push the top of the humidifier back against the duct.

Verify the humidifier is level and fasten the humidifier to the duct using two self-drilling sheet metal screws provided.

MCR29870

2

1

Bypass Model Installation

Humidifier 69-2413EF—058

Page 11: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

MO

UN

TIN

G

Before proceeding to the next step: I secured the humidifier to the duct as instructed.

Bypass mounting is complete. Go to page 11.

Bypass Model Installation

Humidifier 69-2413EF—05 9

STEP FIVE: Bypass Duct InstallationOn the duct opposite the humidifier Bypass install, cut a 6-in. diameter duct hole.• If the humidifier is on the supply duct, the 6-in.

diameter hole should be on the return.• If the humidifier is on the return duct, the 6-in.

diameter hole should be on the supply.

Secure a 6-in. round duct starter collar into the 6-in. duct hole.

Use rigid or aluminized flexible 6-in. duct to connect the starter collar to the humidifier bypass port.

Secure the duct to the humidifier port with self-drilling sheet metal screws using the pre-drilled holes on the bypass port. For added seal, wrap sheet metal tape around the duct to port connection point.

MCR29933

MCR29878

2

2

2

1

1

Page 12: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

MO

UN

TIN

G

STEP THREE: Mounting

Slide the Fan model evenly into the duct hole. Verify the humidifier is level.

Fasten the humidifier to the duct using four self-drilling sheet metal screws provided.

Do not plug the humidifier in yet.

MCR29934

1

2

3

Fan Model Installation

Humidifier 69-2413EF—0510

Page 13: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

MO

UN

TIN

G

Humidifier Control Installation

Humidifier 69-2413EF—05 11

OPTION ONE: Duct Installation of H8908 Humidistat (provided) If a different control is being used, refer to installation instructions provided with that control.

Choose a location on the duct.

Apply sticker template to duct and drill holes formounting screws. Cut along the dotted line of thetemplate with metal shears or tin snips.

Remove the base bracket from the humidistat. Slide the black gasket onto the base bracket.

Secure the base bracket to the duct.Secure to the duct with four 1-in. (25 mm)screws (provided).

ALTERNATE LOCATION

RETURN AIR

RETURN AIR

6 in. (152 mm) MINIMUM 15 in. (381 mm)

MINIMUM

BEST LOCATION

RETURN AIR DUCTM13369

M24800

2

4

1

3

M24733

M29879

Page 14: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

MO

UN

TIN

G

Humidifier Control Installation

Humidifier 69-2413EF—0512

OPTION TWO: Remote Installation of H8908 Humidistat (provided) If a different control is being used, refer to installation instructions provided with that control.

Choose a location in the living area. Select a location clear of drafts or excessive humidity. Avoid mounting near doors or windows, or in bathrooms or kitchens.

Cut 1-in. diameter wire hole in wall.

Run two-fan, low-voltage wire to the mounting location in the living area.

Remove the base bracket from the humidistat.

Secure the base bracket to the remote location with two 1-in. (25 mm) screws (provided).

M29952

M24721

2

2

4

1

M29948

M29949

3

Page 15: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

PL

UM

BIN

G

Water Supply and Drain Connections

STEP ONE: Connect the Water Supply

Use hot or cold water.

Cut the water line so it reaches from the humidifier to the main water supply tap

Insert the water line into the gray quick connect fitting. Insert it fully, and apply modest pull pressure to ensure a tight fit.

Note: The quick connect fitting can be removed if you prefer to use a standard 1/4-in. brass compression nut plumbing connection. Do not remove the conical screen if you select this option.

STEP TWO: Tap into a Water Line• Consult local codes for proper plumbing.• Use the saddle valve provided or a T-fitting and

manual shutoff valve to tap into the water line.• Refer to the literature included with the valve you

chose and the local plumbing codes. Use proper technique for the valve.

• Connect the other end of the humidifier water line to the water valve.

MCR32931

Saddle ValveT-fitting

Water SupplyLine

Manual ShutoffValve

M29605

2

1

Humidifier 69-2413EF—05 13

Page 16: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

PL

UM

BIN

G

STEP THREE: Connect to the Water Drain• Consult and follow local plumbing codes for drain

pipe size and flow requirement. • The ideal installation is directly to the main floor

drain using the rubber hose provided. • If direct floor drain access is not available, see

“Appendix B: Advanced Draining.”

Connect the 1/2-in. drain hose provided to the drain fitting on the bottom of the humidifier.

Use the hose clamp provided to secure the drain hose to the fitting.

Route the drain hose to the floor drain. The hose must have a continuous downward slope.

Direct the hose outlet into the floor drain. Secure the hose to reduce the risk of water pooling or splashing as it drains from the humidifier.

HE300 ONLY: Return Duct InstallationIf a return duct installation is required, a trap must be installed in the drain line. A hard trap is recommended, but a coil in the line, secured with tape or zip tie, is also acceptable.

MCR29881

Before proceeding to Wiring: I have connected the water supply line to the humidifier and the main water tap. I have installed the drain connection. I have checked all plumbing connections for leaks.

4

3

2

1

M32929

Humidifier 69-2413EF—0514

Page 17: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

WIR

ING

What humidifier model do I have?The model number can be found on the bottom of the humidifier.

STEP ONE: Remove the Humidifier Cover

Remove the bottom cover.

STEP TWO: Understand the Wiring Terminals (HE150/HE250/HE300 only)HE150/HE250 Bypass Terminal

Gf: Used to force system fan on when humidity is needed.R: Input from system R. Needed to power Gf when forcing fan on.Gt or W: Input from system G or W. Needed to humidify only during fan or heat calls by system.HUM: Powered contacts for humidity control.C: Common. Needed for Gt or W input. Connect to system C.Power Out: 24V power for electric controls.Power In: Power from 15VA transformer on HE150/HE250 only.SENSOR: Powered contacts for an air proving device when utilized.

MCR29935

MCR29937

Before Wiring the Humidifier

Before wiring the humidifier: I understand and will comply with applicable local wiring codes and regulations. I will read the section “Using the DIP Switches” beginning on the next page.

CAUTION: Voltage Hazard.

Be sure the humidifier is not plugged in before beginning wiring.

1a

M29936

HE300 Fan Terminal

MCR299501b

Humidifier 69-2413EF—05 15

Page 18: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

WIR

ING

Using the DIP Switches (HE150/HE250/HE300 only)Two features are configured by DIP settings, which are described inside the humidifier cover.

STEP THREE: Understand the DIP Switches

DIP 1 (Top): This switch looks for inputs from the HVAC system before allowing humidity. Set to the left, the humidifier will look for input(s). Set to the right, it will not.

DIP 2 (Bottom): This switch controls the fan. Set to the left, the HVAC system controls the fan. Set to the right, the humidifier will force the fan on when there is a call for humidity.

STEP FOUR: Install the Transformer (Bypass Models Only)Install transformer on the outside of a grounded metal junction box using only a 7/8 in. (22 mm) knockout hole. Place mounting tabs into the knockout hole and firmly tighten the locking screw. Field wiring connections and grounding means for the transformer and enclosure shall be in accordance with the National Electrical Code (NEC) and the Canadian Electrical Code (CEC). Connect wires to the 120V side of the transformer.

For HE150 and HE250, the 15V transformer must provide constant power to the 24V IN terminals.

STEP FIVE: Wiring the HumidifierUse a wiring diagram from the following pages that matches your equipment.When wiring is complete, run the wires coming out of the humidifier into the wiring clip on the bottom of the humidifier.

MCR29882

Humidifier 69-2413EF—0516

Page 19: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

WIR

ING

Wiring Configuration: Advanced Models (HE150/HE250/HE300)

Wiring H8908 to humidify only with a call for heat or fan.

Wiring TrueIAQ, VisionPRO IAQ, or Prestige, using the intelligent control to program humidity calls with heat, cool, or on demand.

HE150 OR HE250

DIP SWITCH SETTINGRESET POWER AFTER

ANY DIP SWITCH CHANGES

HE300

H8908

10

OFF ON

20

30 40

50

60

M29938A

POWER IN

G OR WC

OR AIR PROVINGDEVICE

HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN. HE100/HE200 USES A 10 VA TRANSFORMER WIRED INTO 24V IN.

CONNECT G TO HUMIDIFY WHEN THERE IS A FAN CALL. CONNECT W TO HUMIDIFY WHEN THERE IS A HEAT CALL. NEVER CONNECT BOTH. CONNECT C WHEN USING G OR W.

USE AIR PROVING DEVICE INSTEAD OF THE G/W CONNECTION TO HUMIDIFY ANY TIME THE FAN IS OPERATING.

1

1

2

3

3

2

HE300 USES A LINE CORD PLUG.

CONNECT G TO HUMIDIFY WHEN THERE IS A FAN CALL. CONNECT W TO HUMIDIFY WHEN THERE IS A HEAT CALL. NEVER CONNECT BOTH. CONNECT C WHEN USING G OR W.

USE AIR PROVING DEVICE INSTEAD OF THE G/W CONNECTION TO HUMIDIFY ANY TIME THE FAN IS OPERATING.

1

3

2

H8908

10

OFF ON

20

30 40

50

60

POWER IN

G OR W

CAIR PROVINGDEVICE

1

2 3OR

M29939A

FROMHUMIDITYCONTROL

HE150 OR HE250

DIP SWITCH SETTINGRESET POWER AFTER

ANY DIP SWITCH CHANGES

HE300

POWER IN

HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN. HE100/HE200 USES A 10 VA TRANSFORMER WIRED INTO 24V IN.

1

1

HE300 USES A LINE CORD PLUG.1

POWER IN

FROMHUMIDITYCONTROL

1

Humidifier 69-2413EF—05 17

Page 20: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

WIR

ING

Wiring Configuration: Advanced Models (HE150/HE250/HE300)

Wiring to force the HVAC system fan on whenever humidity is needed (on demand).

Wiring to force fan on and prove airflow in the duct.

ONLY NEEDED IF SYSTEM’S THERMOSTAT DOES NOT ISOLATE Y FROM G. IF NEEDED, BREAK THE THERMOSTAT G TO SYSTEM G CONNECTION AND ROUTE THROUGH HUMIDIFIER AS SHOWN.

HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN. HE100/HE200 USES A 10 VA TRANSFORMER WIRED INTO 24V IN.

1

2

ONLY NEEDED IF SYSTEM’S THERMOSTAT DOES NOT ISOLATE Y FROM G. IF NEEDED, BREAK THE THERMOSTAT G TO SYSTEM G CONNECTION AND ROUTE THROUGH HUMIDIFIER AS SHOWN.

HE300 USES A LINE CORD PLUG.

1

2

M29941A

G (FURNACE)

G (THERMOSTAT) 1

POWER OUT24V FOR

ELECTRONICHUMIDISTAT

HE150 OR HE250

DIP SWITCH SETTINGRESET POWER AFTER

ANY DIP SWITCH CHANGES

HE300

POWER IN2

R

POWER IN2

FROMHUMIDITYCONTROL

AFS AFS

G (FURNACE)

G (THERMOSTAT) 1

POWER OUT24V FOR

ELECTRONICHUMIDISTAT

RFROM

HUMIDITYCONTROL

M29940A

G (FURNACE)

G (THERMOSTAT)

ONLY NEEDED IF SYSTEM’S THERMOSTAT DOES NOT ISOLATE Y FROM G. IF NEEDED, BREAK THE THERMOSTAT G TO SYSTEM G CONNECTION AND ROUTE THROUGH HUMIDIFIER AS SHOWN.

HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN. HE100/HE200 USES A 10 VA TRANSFORMER WIRED INTO 24V IN.

1

1

POWER OUT24V FOR

ELECTRONICHUMIDISTAT

2

ONLY NEEDED IF SYSTEM’S THERMOSTAT DOES NOT ISOLATE Y FROM G. IF NEEDED, BREAK THE THERMOSTAT G TO SYSTEM G CONNECTION AND ROUTE THROUGH HUMIDIFIER AS SHOWN.

HE300 USES A LINE CORD PLUG.

1

2

HE150 OR HE250

DIP SWITCH SETTINGRESET POWER AFTER

ANY DIP SWITCH CHANGES

HE300

POWER IN2

R

POWER IN2

FROMHUMIDITYCONTROL

G (FURNACE)

G (THERMOSTAT) 1

POWER OUT24V FOR

ELECTRONICHUMIDISTAT

RFROM

HUMIDITYCONTROL

Humidifier 69-2413EF—0518

Page 21: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

WIR

ING

Wiring Configuration: Advanced Models (HE150/HE250/HE300)

Wiring TrueEASE to equipment with powered terminals.

Wiring TrueEASE to equipment with powered terminals.

Wiring Configuration: Basic Models (HE100/HE200)

ADD 24VAC ISOLATION RELAY (SUCH AS R8222B1067) BETWEEN THE HUMIDIFIER AND THE AIR HANDLER.

THE 50027910-001 AIR-FLOW SWITCH (AFS) IS RECOMMENDED TO ENSURE AIR FLOW WHEN THE HUMIDIFIER IS RUNNING. IF THE AFS IS USED, SET DIP SWITCH 1 TO OFF (LEFT).

HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN. HE100/HE200 USES A 10 VA TRANSFORMER WIRED INTO 24V IN.

WIRING DIAGRAM ASSUMES THE USE OF EQUIPMENT-SPECIFIC COMMUNICATING THERMOSTAT CONTROLLING THE HUMIDIFIER.

1

2

3

4

4 4

4

ADD 24VAC ISOLATION RELAY (SUCH AS R8222B1067) BETWEEN THE HUMIDIFIER AND THE AIR HANDLER.

THE 50027910-001 AIR-FLOW SWITCH (AFS) IS RECOMMENDED TO ENSURE AIR FLOW WHEN THE HUMIDIFIER IS RUNNING. IF THE AFS IS USED, SET DIP SWITCH 1 TO OFF (LEFT).

HE300 USES A LINE CORD PLUG.

WIRING DIAGRAM ASSUMES THE USE OF EQUIPMENT-SPECIFIC COMMUNICATING THERMOSTAT CONTROLLING THE HUMIDIFIER.

1

2

3

M33040

COM HUM R G

HE150 OR HE250

DIP SWITCH SETTINGRESET POWER AFTER

ANY DIP SWITCH CHANGES

HE300

POWER IN

31 1

2

2

POWER IN3

AFS AFS

COM HUM R G

M33039

HUMIDIFIER

WATER SOLENOIDLEAD WIRE

COM

HUM

R

G

WIRING DIAGRAM ASSUMES THE USE OF EQUIPMENT-SPECIFIC COMMUNICATING THERMOSTAT CONTROLLING THE HUMIDIFIER.

1

1

Humidifier 69-2413EF—05 19

Page 22: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

WIR

ING

Wiring Configuration: Basic Models (HE100/HE200)

Wiring H8908 with fan interlock.

Wiring H8908 with 2-speed fan motor.

1

1

H L

C

2

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.

24 VAC WIRING.

2

TRANSFORMER

2-SPEEDFANMOTOR

DPSTSWITCHINGRELAY

FAN CONTROL

L1(HOT)

L2

M29942A

POWERSUPPLY

H8908

10

OFF ON

20

30 40

50

60

HUMIDIFIER

WATER SOLENOIDLEAD WIRE

H8908

1

2

HUMIDIFIER

TRANSFORMER

FURNACEFANMOTOR

FAN CONTROL

L1(HOT)

L2

M29945A

POWERSUPPLY

10

OFF ON

20

30 40

50

60

1

2

PROVIDE DISCONNECT MEANS ANDOVERLOAD PROTECTION AS REQUIRED.

24 VAC WIRING.

WATER SOLENOIDLEAD WIRE

Humidifier 69-2413EF—0520

Page 23: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

WIR

ING

Wiring Configuration: Basic Models (HE100/HE200)

Wiring H8908 with current-sensing relay.

Wiring H8908 in line with air proving device.

M29943A

L1 (HOT)

L2 1

2

1

2

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.

24V WIRING.

TRANSFORMER

CURRENTSENSINGRELAY C

LOHI

H8908

10

OFF ON

20

30 40

50

60

HUMIDIFIER

WATER SOLENOIDLEAD WIRE

M29944A

L1 (HOT)

L21

2

1

2

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.

24V WIRING.

TRANSFORMER

AIR PROVINGDEVICE

H8908

10

OFF ON

20

30 40

50

60

HUMIDIFIER

WATER SOLENOIDLEAD WIRE

Humidifier 69-2413EF—05 21

Page 24: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

OP

ER

AT

ION

A

ND

SE

RV

ICE

When installation is complete, follow the steps below. Make sure the humidifier is running properly before turning the system over to the homeowner. Once the humidifier is running, day-to-day operation is automatic. The homeowner can use the control to adjust the humidity levels and turn the humidifier on or off.

Snap the bottom cover into place.

Turn on the water supply at the saddle valve or T-fitting and manual shutoff valve. Water will flow to the humidifier but will not pass through the pad until the humidity control is turned on.

Plug in the humidifier (HE300) or apply HVAC system power (HE100/HE150/HE200/HE250)• On advanced models, the LED lights will blink for

3-5 seconds to verify that there is system power.

On HE100/HE200, turn the Damper Position knob on the bypass outlet so that it is parallel to the bypass outlet. On HE150/HE250, the humidifier does this automatically. Not applicable for HE300.

Turn the humidity control to On.• If your wiring is configured for operation only with

heat or fan, make the appropriate system demands to allow humidification.

• Make sure air is blowing through the ductwork with the humidifier call.

The Humidifying light will be solidly on when water is flowing through the humidifier pad• On HE150/HE250 models, remove the humidifier’s

top cover to verify water flow through the top tray and into the pad. Make sure that the damper rotates open when humidity is on, and rotates closed when humidity is off.

• On HE300 models, verify water is exiting the drain hose.

MCR29884

Startup and Checkout

Check all water line and drain connections to ensure there are no leaks before leaving the job site.• Check for leaks immediately after turning the main water supply on, and again after 15 minutes of humidifier

operation.

Turn the setpoint to the homeowner’s desired level when testing is complete. If humidity is not needed, set the control to Off, and turn the Damper Position knob on the bypass outlet so that it is perpendicular to the bypass outlet (HE100/HE200 only).

Humidifier 69-2413EF—0522

3

2

1

4

5

6

Page 25: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

OP

ER

AT

ION

A

ND

SE

RV

ICE

It is recommended that the humidifier pad be replaced once per year. This can be done at the beginning or the end of the dry season. The humidifier design makes this annual replacement quick and easy, providing one-step access to the pad.

Routine Maintenance

Bypass:

1a. Pad can be replaced from the side by gripping the black handle and pulling out, or from the front by removing the humidifier’s top cover and rocking the pad forward and out. Humidifier pad might remove from other side of humidifier, depending on installation.

MCR29885

25%

Fan:

1b. Pad can be replaced from the front by gripping the black handle and pulling out.

MCR29886

2. Remove tray on top of the pad, and wipe free any sediment present within the tray.3. Replace the old pad with the new, making sure pad is oriented correctly (see pad box). Wipe free any

sediment present inside the pad frame.4. Reseat the tray on top of the pad with the arrows inside the tray pointing into the duct. Then reinsert the frame

into the humidifier.5. Afer pad replacement is complete, remove the bottom cover and press the RESET button to reset the

maintenance timer.

Humidifier 69-2413EF—05 23

21

Page 26: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

OP

ER

AT

ION

A

ND

SE

RV

ICE

Humidifier 69-2413EF—0524

Problem What To Look For What To Do

Low humidity Furnace blower not

operating

1. Reset circuit breaker or check for blown fuse.

2. Check that the furnace power is on.

3. Check all external wiring connections.

4. Check the humidity control setting.

Rapid air changes or

drafts

1. Keep doors and windows closed.

2. Close fireplace damper when not in use.

3. Keep exhaust fan running time to a minimum.

4. Seal around doors and windows.

High humidity Condensation on walls 1. Turn off humidity control and water until condensation is completely

evaporated.

Heavy condensation on

windows

1. Turn humidity control down low enough to eliminate condensation

caused by moisture. If moisture persists, more ventilation is needed.

Replace Pad

light is on

(HE150/HE250/

HE300)

This is the yearly

maintenance reminder to

replace the pad inside the

humidifier

1. Refer to the parts list and replace the pad for your humidifier model.

2. Once pad is replaced, press the RESET button under the wire cover.

Service light is on

(HE150/HE250)

The damper inside the

bypass has failed to open

completely

1. Press RESET button under the wire cover.

2. Verify the damper plug is connected on the side of the humidifier the

bypass outlet is on.

3. Ensure there is no interference from sheet metal screws that connect

the bypass to ducting.

4. If fault persists, replace bypass damper motor.

Air proving device has

detected a lack of air

movement

Only possible with DIPs

configured as:

1. Check wiring to Air Flow Switch.

2. Confirm DIP switch configuration and wiring on the humidifier is correct.

3. Check location of Air Flow Switch to ensure it is properly placed in duct

to detect air.

4. Check switch relays.

5. If fault persists, replace Air Flow Switch.

Service light is on

(HE300)

The fan motor has failed 1. Press RESET button under the wire cover.

2. Unplug the humidifier and plug it back in.

3. If fault persists, replace motor assembly.

Air proving device has

detected a lack of air

movement

Only possible with DIPs

configured as:

1. Check wiring to Air Flow Switch.

2. Confirm DIP switch configuration and wiring on the humidifier is correct.

3. Check location of Air Flow Switch to ensure it is properly placed in duct

to detect air.

4. Check switch relays.

5. If fault persists, replace Air Flow Switch.

Troubleshooting

Page 27: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

OP

ER

AT

ION

A

ND

SE

RV

ICE

Humidifier 69-2413EF—05 25

Humidifying Capacity

At 120°F (49°C) plenum temperature and 0.20 static pressure

drop across supply and return:

HE100/150: up to 12 gallons per day (gpd)

(46 liters per day [lpd])

HE200/250: up to 17 gpd (65 lpd)

HE300: up to 18 gpd (68 lpd)

Humidified Area

HE100/150: Up to 16,000 cubic feet

HE200/250: Up to 20,000 cubic feet

HE300: Up to 24,000 cubic feet

Dimensions

HE100/150: 14.5 in. W x 14 in. H x 10.1 in. D

(368 mm W x 356 mm H x 257 mm D)

HE200/250: 15 in. W x 17.15 in. H x 10.1 in. D

(381 mm W x 436 mm H x 257 mm D)

HE300: 15.5 in. W x 16.8 in. H x 10.3 in. D

(394 mm W x 427 mm H x 262 mm D)

Humidifier Pad Dimensions

HE100/150: 9-1/2 in. W x 9-13/16 in. H x 1-1/2 in. D

(241 mm W x 249 mm H x 38 mm D)

HE200/250: 10 in. W x 13 in. H x 1-1/2 in. D

(254 mm W x 330 mm H x 38 mm D)

HE300: 10 in. W x 13 in. H x 1-1/2 in. D

(254 mm W x 330 mm H x 38 mm D)

Static Pressure

HE100/150/: Supply plenum static pressure no greater

200/250 than .3 in. w.c.

HE300: Supply plenum static pressure no greater

than .4 in. w.c.

Plenum Opening Dimensions

HE100/150: 9-5/16 in. W x 9-7/16 in. H (238 mm W x 241 mm H)

HE200/250: 9-3/4 in. W x 12-5/8 in. H (248 mm W x 321 mm D)

HE300: 13-1/2 in. W x 14-1/16 in. H (343 mm W x 357 mm D)

Bypass Duct Opening Dimensions (HE100/150/200/250)

6 in. (152 mm)

Operating Ranges

34ºF–90ºF (1.1ºC–32ºC)

Humidity: 0–95% RH, non-condensing

Drain Fitting

1/2 in. (13 mm) I.D. plastic hose connected directly to drain

fitting on unit.

Electrical Ratings and Tolerances

HE100/200: 24VAC, 60 Hz, 0.5 A maximum

HE150/250: 24VAC, 60 Hz, 0.75 A maximum

HE300: 120VAC, 60 Hz, 1 A maximum

A: Specifications

Page 28: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

AP

PE

ND

ICE

S

Humidifier 69-2413EF—0526

B: A

dvan

ced

Dra

inin

g

Opt

ion

1: P

lum

bing

to d

rain

with

co

nden

sate

pum

p.

• Pu

mp

with

(140

°F te

mpe

ratu

re ra

ting,

> 5

GPH

pum

pflo

w ra

te, w

ith 9

-foot

rise

).

• P

ump

mus

t be

pow

ered

whe

n hu

mid

ifier

is o

pera

ting.

• U

se a

pum

p w

ith a

bui

lt-in

ove

rflow

sen

sor o

r ins

tall

the

pum

p in

a d

rip p

an w

ith w

et s

witc

h w

ired

to tu

rn o

ff hu

mid

ifier

.

• Su

ppor

t rub

ber h

ose

ever

y 6

in.

• PV

C m

ust b

e sc

hedu

le 4

0 or

hig

her r

atin

g.

• Al

l pla

stic

pip

e jo

ints

are

wel

ded.

• D

rain

into

a P

-trap

that

will

rem

ain

wet

ted

at a

ll tim

es.

1-1/

2 IN

. MIN

IMU

M T

RAP

(O

R S

IZE

PER

LO

CAL

CO

DE)

VEN

TED

PER

LOC

AL C

OD

E

ALL

PLAS

TIC

PIP

EJO

INTS

AR

E W

ELD

ED

1/2

IN. M

NPT

X S

WEA

T1/

2 IN

. FN

PT X

1-1

/2 IN

. PVC

1-1/

2 IN

. PVC

1/2

IN. (

MIN

IMU

M) P

VC P

IPE

1/2

IN. F

NPT

X 1

-1/2

IN. P

VC

1/2

IN. M

NPT

X 1

/2 IN

. CPV

C

1/2

IN. F

NPT

X 1

-1/2

IN. P

VC

HO

SE C

LAM

P1/

2 IN

. BAR

B X

1/2

IN. M

NPT

SIZE

TO

FIT

PU

MP

OU

TPU

T

Opt

ion

2: P

lum

bing

to a

ded

icat

ed tr

ap.

HO

SE C

LAM

PS A

TAL

L C

ON

NEC

TIO

NS

3/8-

IN. T

UBI

NG

R

ATED

AT

212°

F

3/4

IN. F

NPT

X 3

/4 IN

. CPV

C

3/4

IN. C

PVC

PIP

ETO

PU

MP

ALTE

RN

ATIV

EH

OSE

FR

OM

HU

MID

IFIE

R

FOR

ALL

OPT

ION

S SH

OW

N:

1/2

IN. M

NPT

X S

WEA

T

1/2

IN. F

NPT

X 1

-1/2

IN. P

VC

1-1/

2 IN

. PVC

1/2

IN. (

MIN

IMU

M)

PVC

PIP

E

1/2

IN. F

NPT

X 1

-1/2

IN. P

VC

1/2

IN. M

NPT

X 1

/2 IN

. CPV

C

1/2

IN. F

NPT

X 1

-1/2

IN. P

VC

HO

SE C

LAM

P1/

2 IN

. BAR

B X

1/2

IN. M

NPT

MC

R29

888

ALL

CO

NN

ECTI

ON

S FR

OM

SO

LEN

OID

VAL

VE T

O

DR

AIN

TR

AP A

RE

SEAL

ED

SIN

K

1-1/

2 IN

. PV

C T

EE

1-1/

2 IN

. PVC

1-1/

2 IN

.PV

C

CO

UPL

ING

WEL

D

WEL

D

STAI

NLE

SS S

TEEL

SL

OTT

ED B

AND

C

OU

PLIN

G S

IZED

TO

FIT

PIPE

(CO

PPER

, PV

C, C

PVC

)

SIZE

TO

FIT

PU

MP

OU

TPU

T

ALTE

RN

ATIV

ETH

IS C

ON

FIG

UR

ATIO

N A

LLO

WS

FOR

R

EMO

VAL

OF

THE

TRAP

THR

EAD

SW

ELD

Opt

ion

4: P

lum

bing

to s

ink

trap.

1/2

IN. M

NPT

X S

WEA

T1/

2 IN

. FN

PT X

1-1

/2 IN

. PVC

1/2

IN. P

VC

1/2

IN. (

MIN

IMU

M)

PVC

PIP

E

1/2

IN. F

NPT

X 1

-1/2

IN. P

VC

1/2

IN. M

NPT

X 1

/2 IN

. CPV

C

3/4

IN. F

NPT

X 1

-1/2

IN. P

VC

HO

SE C

LAM

P3/

8 IN

. BAR

B X

3/4

IN. M

NPT

ALL

PLAS

TIC

PIP

E U

ND

ER

SIN

K 1-

1/2

IN. M

INIM

UM

PVC

ALL

CO

NN

ECTI

ON

S FR

OM

SO

LEN

OID

VAL

VE T

O

DR

AIN

TR

AP A

RE

SEAL

ED

SIN

K

CO

UPL

ING

WEL

D

WEL

D

THR

EAD

S

THR

EAD

S

WEL

D

WYE

ALTE

RN

ATIV

ETH

IS C

ON

FIG

UR

ATIO

N A

LLO

WS

FOR

R

EMO

VAL

OF

THE

TRAP

SIZE

TO

FIT

PU

MP

OU

TPU

T

Opt

ion

3: P

lum

bing

to s

ink

with

a

dedi

cate

d tra

p.

1/2

IN. C

OPP

ER P

IPE

1/2

IN. F

NPT

X S

WEA

T

HO

SEC

LAM

PS

HO

SE F

RO

MH

UM

IDIF

IER

140°

F R

ATED

PU

MP

>5 G

PH F

LOW

RAT

EW

ITH

9-F

T R

ISE

1/2

IN. B

ARB

X 1/

2 IN

. MN

PT

FLEX

IBLE

HO

SE

SEAL

ALL

CO

NN

ECTI

ON

S FR

OM

SOLE

NO

ID V

ALVE

TO

DR

AIN

STA

CK

1/2

IN. F

NPT

X1/

2 IN

. PVC

1/2

IN. (

MIN

IMU

M) P

VC P

IPE

1/2

IN. F

NPT

X 1

/2 IN

. CPV

C

1/2

IN. C

PVC

PIP

E

1/2-

IN. T

UBI

NG

R

ATED

AT

140°

F

Con

nect

to h

umid

ifier

.C

omm

on to

all

plum

bing

opt

ions

.

STAI

NLE

SS S

TEEL

SL

OTT

ED B

AND

C

OU

PLIN

G S

IZED

TO

FIT

PIPE

(CO

PPER

, PV

C, C

PVC

)W

ELD

1-1/

2 IN

. PVC

Page 29: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

AP

PE

ND

ICE

S

M29951

16

17

18

19

M32932

x 25

x 25LO

AD

R

C

3 4

5 6

89

7

21 11

10

12

13 14

15

20 21

22

23

Humidifier 69-2413EF—05 27

C: Parts List

Page 30: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

Figure Reference

Part Number Part Description Use With Model

N/A HC26E1004 Large AgION coated replacement pad HE200, HE250. HE300

N/A HC26A1008 Large standard replacement pad HE200, HE250, HE300

N/A HC22E1003 Small AgION coated replacement pad HE100, HE150

N/A HC22A1007 Small standard replacement pad HE100, HE150

N/A 32001616-001 Saddle valve HE100, HE150, HE200,

HE250, HE300

1 50041883-002 AC Solenoid valve HE100, HE200

2 50041883-001 DC Solenoid valve HE150, HE250, HE300

3 50041861-001 Frame and tray assembly for small bypass model HE100, HE200

4 50041861-002 Frame and tray assembly for large bypass model HE150, HE250

5 50052641-001 Top cover for small bypass model HE100, HE150

6 50052641-002 Top cover for large bypass model HE200, HE250

7 50041888-001 Small bypass duct with manual damper HE100

8 50041888-002 Large bypass duct with manual damper HE200

9 50041890-001 Small bypass duct with automatic damper HE150

10 50041890-002 Large bypass duct with automatic damper HE250

11 50041886-001 Bottom cover for small basic bypass model HE100

12 50041887-001 Bottom cover for large basic bypass model HE200

13 50052642-001 Bottom cover for small advanced bypass model HE150

14 50052642-002 Bottom cover for large advanced bypass model HE250

15 50057547-002 HE150 circuit board HE150

50057547-003 HE250 circuit board HE250

16 50045729-001 Blower and motor assembly with isolator HE300

17 50057547-001 HE300 circuit board HE300

18 50041919-001 Frame and tray assembly for fan model HE300

19 50052653-001 Wire terminal cover for fan model HE300

20 32001652-001 10V transformer HE100, HE200

21 50050349-001 15V transformer HE150, HE250

22 50032048-002 Qty 25 Residential humidifier quick connect adapter HE100, HE150, HE200,

HE250, HE300

23 32001647-001 Qty 25 Residential humidifier cone screen filter HE100, HE150, HE200,

HE250, HE300

Automation and Control Solutions

Honeywell International Inc.

1985 Douglas Drive North

Golden Valley, MN 55422

http://yourhome.honeywell.com

® U.S. Registered Trademark© 2011 Honeywell International Inc.69-2413EF—05 M.S. Rev. 07-11Printed in U.S.A.

Page 31: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

M32930

69-2413EF-05

Système d’humidification TrueEASE™GUIDE D’INSTALLATION PROFESSIONNEL

INCLUS DANS LA BOÎTE DE CET HUMIDIFICATEUR

Outils requis pour installer l’humidificateur Coupe-fil/outil à dénuder

Cisailles à tôles

Tournevis à douille hexagonale n° 8

Tournevis normal

Fil de calibre 18 (jusqu’à 5 conducteurs)

Autres exigences

Si un drain de plancher n’est pas disponible, consultez l’annexe A pour les pièces de plomberie supplémentaires.

Si l’installation a lieu dans un espace fini ou au-dessus, Honeywell recommande d’installer un plateau d’écoulement avec un système de détection de fuite d’eau avec dispositif de coupure.

A1 Dérivation de l’humidificateurA2 Ventilateur de l’humidificateur

Vanne à étrier

Canalisation d’arrivée d’eau

Conduite de vidange (10 pieds)E Manuel du propriétaireF Gabarit de montageG Régulateur d’humidité manuel H8908

Quincaillerie (non illustrée) Accessoires supplémentaires inclus avec certains modèles

E

A1 A2

F G

PO

UR

C

OM

ME

NC

ER

MO

NTA

GE

PL

OM

BE

RIE

BL

AG

E

AN

NE

XE

SF

ON

CT

ION

NE

ME

NT

E

T R

ÉPA

RA

TIO

N

Tableau des correspondancesHumidificateur Honeywell® Aprilaire® GeneralAire®

HE100 et HE150 HE225 500 570

HE200 et HE250 HE265 600 900

HE300 HE365 700 1000

Page 32: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models
Page 33: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

Humidificateur

BESOIN D’AIDE? Pour de l’assistance au sujet de ce produit, veuillez consulter le site

http://yourhome.honeywell.com ou téléphoner sans frais aux Services à la clientèle de

Honeywell au 1-800-468-1502.

?

Humidifier 69-2413EF—05 1

Lire et conserver ces instructions.® Marque de commerce déposée aux États-Unis. Brevets en instance. Copyright © 2011 Honeywell International Inc. Tous droits réservés.

POUR COMMENCER

Définitions et précautions relatives à la sécurité . . . . 2

Qu’attendre de votre humidificateur? . . . . . . . . . . . . 3

Exigences d’installation importantes . . . . . . . . . . . . . 4

MONTAGE

Choix d’une méthode de montage . . . . . . . . . . . . . . . 5

ÉTAPE 1: Choix d’un emplacement de montage . 6

ÉTAPE 2 : Installation du gabarit de montage

dans la gaine . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Installation du modèle à dérivation . . . . . . . . . . . . . . 7

ÉTAPE 3 : Configuration de la dérivation

de l’humidificateur . . . . . . . . . . . . . . . . . . . . . . 7

ÉTAPE 4 : Installation . . . . . . . . . . . . . . . . . . . . . 8

ÉTAPE 5 : Installation de la gaine de dérivation. . 9

Installation du modèle à ventilateur . . . . . . . . . . . . . 10

ÉTAPE 3 : Installation . . . . . . . . . . . . . . . . . . . . 10

Installation du régulateur l’humidificateur . . . . . . . . 11

OPTION 1 : Installation en gaine

de l’humidistat H8908 . . . . . . . . . . . . . . . . . . 11

OPTION 2 : Installation à distance

de l’humidistat H8908 . . . . . . . . . . . . . . . . . . 12

PLOMBERIE

Raccords d’arrivée et de vidange d’eau . . . . . . . . . 13

ÉTAPE 1 : Connexion de l’arrivée d’eau . . . . . . 13

ÉTAPE 2 : Raccord dans une

canalisation d’eau . . . . . . . . . . . . . . . . . . . . . 13

ÉTAPE 3 : Raccord à la vidange d’eau . . . . . . . 14

CÂBLAGE

Avant de raccorder l’humidificateur . . . . . . . . . . . . . 15

ÉTAPE 1 : Retrait du couvercle

de l’humidificateur . . . . . . . . . . . . . . . . . . . . . 15

ÉTAPE 2 : Comprendre les bornes de câblage . . 15

ÉTAPE 3 : Comprendre les commutateurs DIP . 16

ÉTAPE 4 : Installation du transformateur

(modèles à dérivation uniquement) . . . . . . . . 16

ÉTAPE 5 : Câblage de l’humidificateur . . . . . . . 16

Configuration du câblage : Modèles avancés

(HE150/HE250/HE300) . . . . . . . . . . . . . . . . . . . . . . 17

Configuration du câblage : Modèles de base

(HE100/HE200) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

FONCTIONNEMENT ET RÉPARATION

Démarrage et vérification . . . . . . . . . . . . . . . . . . . . 21

Entretien de routine . . . . . . . . . . . . . . . . . . . . . . . . . 22

Dépannage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

ANNEXES

A: Spécifications . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

B : Notions avancées de vidange . . . . . . . . . . . . . . 25

C : Liste des pièces . . . . . . . . . . . . . . . . . . . . . . . . . 26

PO

UR

C

OM

ME

NC

ER

MO

NTA

GE

PL

OM

BE

RIE

BL

AG

E

AN

NE

XE

SF

ON

CT

ION

NE

ME

NT

E

T R

ÉPA

RA

TIO

N

Page 34: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

PO

UR

C

OM

ME

NC

ER

Définitions et précautions relatives à la sécurité

Définitions relatives à la sécuritéLes termes de sécurité identifient des informations qu’il faut lire avant d’installer ou d’utiliser l’humidificateur.

MISE EN GARDE : Indique une situation dangereuse qui, si elle n’est pas évitée, risque d’endommager le produit ou de causer des blessures corporelles.

AVERTISSEMENT : Indique une situation dangereuse qui, si elle n’est pas évitée, risque de causer des blessures graves, voire mortelles.

Précautions relatives à la sécuritéAssurez-vous de lire et de comprendre les risques d’accident suivants avant d’installer, d’utiliser ou de manipuler l’humidificateur:

MISE EN GARDE : Danger de tension. Peut causer des chocs électriques ou des dégâts matériels. Débranchez l’équipement de CVCA et toute prise électrique utilisée pour l’installation de l’humidificateur.

AVERTISSEMENT : Électrocution et danger causé par l’eau.Peut causer la mort, la cécité, des dégâts d’eau domestiques et des défaillances de l’équipement de CVCA.

MISE EN GARDE : Risque de condensation, d’incendie et de gel de l’eau. Peut causer la défaillance du ventilateur ou du limiteur, de même que des dégâts d’eau domestiques.

Humidificateur 69-2413EF—052

Page 35: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

PO

UR

C

OM

ME

NC

ER

L’installateur doit considérer ces points avec le propriétaire et répondre à toute question avant de quitter le site des travaux.

• Établissement du point de consigne d’humidité. Un fonctionnement continu jusqu’à une semaine peut être requis pour atteindre le point de consigne d’humidité, en particulier si l’air de la maison est sec lorsque l’humidificateur est installé. Ceci peut aussi dépendre de facteurs comme la température, la superficie de la maison, l’ameublement et l’isolation.

• Humidité idéale. Les experts de l’industrie de la construction résidentielle citent une humidité relative de 35% pour un confort idéal et pour préserver l’habitation durant la saison sèche typique. Les propriétaires peuvent ajuster les réglages selon leur propre confort ou jusqu’à ce qu’il y ait de la condensation sur les fenêtres. Abaissez le point de consigne si de la condensation se forme.

• L’unité ne génère pas d’humidité. Si l’humidificateur ne fonctionne pas, mais l’humidité est sous le point de consigne, le régulateur d’humidité peut être doté d’un réglage de protection contre le gel pour éviter la formation de condensation sur les fenêtres.

• Ventilation résidentielle. Une ventilation excessive chasse l’air humide à l’extérieur et le remplace par de l’air sec. Il peut alors être difficile de maintenir le point de consigne d’humidité. Si vous installez un ventilateur, utilisez une solution qui conserve l’humidité. L’utilisation d’un ventilateur récupérateur d’énergie (ERV) est recommandée.

• Exigences de nettoyage. Il est recommandé de remplacer le tampon de l’humidificateur et de nettoyer les bacs d’eau du humidificateur au moins une fois par an. Consultez la section Fonctionnement et réparation pour les détails.

• Consommation d’énergie. Il est important d’expliquer qu’avec toute solution d’humidification, un coût est associé à la conversion de l’eau en humidité. L’humidificateur utilise la chaleur de l’air et le débit d’air dans les gaines pour faire cette conversion, ce qui entraîne des coûts en gaz et/ou en électricité dépendant du type et de la configuration de votre système de CVCA.

Qu’attendre de votre humidificateur?

Humidificateur 69-2413EF—05 3

Page 36: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

PO

UR

C

OM

ME

NC

ER

Sécurité personnelle• Portez des lunettes de protection lors de l’installation de l’humidificateur. • Assurez-vous de ne pas entailler la canalisation électrique ou de refroidissement de l’air. • Respectez les normes de sécurité professionnelles et les législations locales concernant la plomberie,

l’électricité et les installations mécaniques.

Emplacement de montage• Montez l’humidificateur à niveau pour éviter les dégâts d’eau et assurer une puissance maximale. • L’emplacement doit offrir un accès à une conduite d’eau, un système d’évacuation et une alimentation

électrique.• N’installez pas l’humidificateur si la température ambiante est inférieure à 1,1 °C (34 °F) ou supérieure à

40 °C (90 °F).• La surface de montage doit être suffisamment robuste pour supporter le poids de l’humidificateur (jusqu’à

16 livres pour le modèle à ventilateur ou 10 livres pour le modèle à dérivation). • Ne montez pas directement l’appareil sur le panneau de gaine. • S’il est utilisé près d’une piscine ou d’un spa, assurez-vous que l’humidificateur ne peut pas tomber dans

l’eau ou être éclaboussé.• Assurez-vous que le couvercle supérieur et le couvercle inférieur de l’humidificateur peuvent être retirés et

que le tampon est accessible à partir de l’emplacement sélectionné.

Arrivée d’eau et évacuation de l’eau• Consultez les codes de plomberie locaux pour connaître la dimension du tuyau de vidange, les matériaux et

la température maximale permise.

En cas de remplacement d’un ancien humidificateur à dérivation

Les dimensions et la forme de l’humidificateur ne sont pas identiques aux autres humidificateurs à dérivation de Honeywell. Avant de moderniser l’installation, il sera peut-être nécessaire d’effectuer les étapes suivantes :• Raccordez l’humidificateur à sec sur la tuyauterie, la plomberie et le câblage avant de l’attacher à la gaine

pour garantir que les raccords existants sont assez longs pour l’atteindre.• Si l’ouverture de la gaine de l’ancien humidificateur n’est pas de la taille adaptée à l’humidificateur,

choisissez un nouvel emplacement ou couvrez l’ancienne ouverture avec un morceau de tôle et coupez une nouvelle ouverture dédiée à l’humidificateur à l’aide du gabarit fourni.

Exigences d’installation importantes

Le non-respect de ces exigences annulera la garantie, nuira à l’installation et entraînera des appels

de service injustifiés.

Tableau des correspondancesHumidificateur Honeywell® Aprilaire® GeneralAire®

HE100 et HE150 HE225 500 570

HE200 et HE250 HE265 600 900

HE300 HE365 700 1000

Humidificateur 69-2413EF—054

Page 37: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

MO

NTA

GE

L’installation dépend du modèle à installer, l’humidificateur à dérivation ou ventilateur :

Quel modèle d’humidificateur possédez-vous?

Dérivation :

Les humidificateurs à dérivation utilisent la différence de pression entre l’arrivée et le retour pour déplacer l’air de gaine par l’humidificateur. Un accès à la gaine d’arrivée et de retour est requis. L’humidificateur à dérivation peut être placé sur la gaine d’arrivée ou de retour.

MCR29871

Ventilateur:

Les humidificateurs à ventilateur utilisent le ventilateur à l’intérieur de l’humidificateur pour acheminer l’air de gaine par l’humidificateur. Honeywell recommande fortement de monter le HE300 sur la gaine d’arrivée pour obtenir les capacités d’humidification maximales. Si une gaine de retour doit être installée, un collecteur doit être installé dans le tuyau de vidange. Un vrai collecteur est recommandé, mais une boucle dans le tuyau fixée avec un ruban ou une attache est également acceptable. Voir la section Raccords d’arrivée et de vidange d’eau pour les détails.

MCR29929

Choix d’une méthode de montage

Avant de commencer le montage : J’ai confirmé que les codes locaux relatifs aux pratiques de plomberie sont respectés. J’ai choisi un emplacement d’installation qui répond aux exigences de la page 4.

5Humidificateur 69-2413EF—05

Page 38: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

MO

NTA

GE

ÉTAPE 1 : Choix d’un emplacement de montageChoisissez un emplacement qui permet l’accès à un tuyau d’arrivée d’eau. De l’eau chaude ou froide peut être utilisée.

Choisissez une surface verticale ou horizontale sur la tuyauterie de l’équipement de CVCA, avec des dégagements adéquats, qui peut accueillir l’humidificateur.

L’emplacement doit aussi permettre un accès à une alimentation de 120 V c.a. Pour l’humidificateur à ventilateur HE300, le cordon électrique est de 6 pieds de long.

Assurez-vous de choisir un emplacement près d’une évacuation. Consultez les codes de plomberie locaux pour une vidange adéquate. Si aucun drain de plancher principal n’est disponible, consultez l’Annexe B : Notions avancées de vidange.”

ÉTAPE 2 : Installation du gabarit de montage dans la gaine

Placez le gabarit sur la gaine. • Assurez-vous que le gabarit est de niveau et dans

la position désirée sur la gaine. Retirez le dos adhésif et collez le gabarit en appuyant fermement dessus à l’emplacement de montage désiré.

Assurez un dégagement adéquat du serpentin de climatisation dans la gaine. REMARQUE : Le modèle à ventilateur HE300 s’étend de 1-3/4 po dans la gaine. Le modèle à dérivation s’étend de 1/2 po dans la gaine. Assurez un dégagement adéquat dans la gaine.• Pour des performances optimales, maintenez au

moins 61 cm (24 po) d’espace d’air vide en aval dans la gaine.

Coupez la tôle en suivant les contours du gabarit.

MCR29877

M29873

1

MF29874

A-COIL

1-3/4(44)

1/2(13)

VENTILATEUR

DÉRIVATION

4

2

2

3

3

2

1

M32930

6 Humidificateur 69-2413EF—05

Page 39: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

MO

NTA

GE

ÉTAPE 3 : Configuration de la dérivation de l’humidificateur

Configurez la prise de la dérivation de l’humidificateur sur le côté le mieux adapté à l’application.

Si la dérivation doit être de l’autre côté, retirez le couvercle supérieur et le couvercle inférieur

Débranchez le fil du registre et branchez-le de l’autre côté (modèles HE150/HE250 uniquement).

Écartez les attaches de la dérivation pour retirer la dérivation; enclenchez-la de nouveau en position en situant la prise du côté souhaité.

Assurez-vous que le tampon est accessible. La poignée du porte-tampon et le panneau latéral de l’humidificateur peuvent être inversés pour pouvoir retirer le porte-tampon (côté opposé de l’ouverture de la gaine de dérivation).

Pour retirer la poignée du porte-tampon, faites-la glisser vers l’arrière de l’humidificateur puis écartez-la de l’humidificateur.

Pour retirer le panneau latéral opposé, placez un tournevis dans les deux fentes à l’arrière de l’humidificateur et détachez le panneau.

Enclenchez la poignée du porte-tampon et glissez le panneau latéral en place dans la position désirée.

MCR29875

Si le modèle à ventilateur HE300 est installé, passez à la page 10.

Installation du modèle à dérivation

MCR29876

1

1

2

2

3

3

MCR29946

4

5

7Humidificateur 69-2413EF—05

Page 40: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

MO

NTA

GE

ÉTAPE 4 : Montage

Attachez les crochets de support des modèles à dérivation sur le bord inférieur de l’orifice.

Poussez la partie supérieure de l’humidificateur contre la gaine.

Vérifiez que l’humidificateur est à niveau et attachez-le à la gaine à l’aide des deux vis à tôle autotaraudeuses fournies.

MCR29870

2

1

Installation du modèle à dérivation

8 Humidificateur 69-2413EF—05

Page 41: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

MO

NTA

GE

Avant de passer à l’étape suivante : J’ai bien fixé l’humidificateur à la gaine en respectant les instructions.

Le montage de la dérivation est terminé. Passez à la page 11.

Installation du modèle à dérivation

ÉTAPE 5 : Installation de la gaineSur la gaine à l’opposée de la dérivation de l’humidificateur, coupez un orifice de gaine de 6 po de diamètre.• Si l’humidificateur est installé sur la gaine d’arrivée,

l’orifice de 6 po de diamètre doit être sur le retour.• Si l’humidificateur est installé sur la gaine de

retour, l’orifice de 6 po de diamètre doit être sur l’arrivée.

Attachez un collet de gaine rond de 6 po dans l’orifice de gaine de 6 po.

Utilisez une gaine rigide ou aluminiée flexible de 6 po pour connecter le collet de départ à l’orifice de dérivation de l’humidificateur.

Fixez la gaine à l’orifice de l’humidificateur avec des vis à tôle autotaraudeuses en utilisant les trous prépercés sur l’orifice de dérivation. Pour plus d’étanchéité, enroulez du ruban à tôle autour du point de connexion de la gaine à l’orifice.

MCR29933

MCR29878

2

2

2

1

1

9Humidificateur 69-2413EF—05

Page 42: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

MO

NTA

GE

10 Humidificateur 69-2413EF—05

ÉTAPE : Montage

Faites glisser le modèle à ventilateur uniformément dans l’orifice de la gaine. Vérifiez que l’humidificateur est à niveau.

Fixez l’humidificateur sur la gaine à l’aide des quatre vis à tôle autotaraudeuses fournies.

Ne branchez pas l’humidificateur à ce stade.

MCR29934

1

2

3

Installation du modèle à ventilateur

Page 43: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

MO

NTA

GE

11Humidificateur 69-2413EF—05

Installation du régulateur de l’humidificateur

OPTION 1 : Installation en gaine de l’humidistat H8908 (fourni) Si un régulateur différent est utilisé, consultez les instructions d’installation fournies avec le régulateur utilisé

Choisissez un emplacement sur la gaine.

Appliquez un gabarit adhésif sur la gaine et les orifices de perçage pour les vis de montage. Coupez le long des pointillés du gabarit avec des cisailles à tôle.

Retirez le support de base de l’humidistat. Glissez le joint noir sur le support de base.

Fixez le support de base à la gaine. Fixez à la gaine avec quatre vis de 25 mm (1 po) fournies.

EMPLACEMENTS POSSIBLES

RETOURD’AIR

RETOURD’AIR

MAXIMUM152 mm (6 po) MINIMUM

381 mm (15 po)

EMPLACEMENTPRÉFÉRABLE

GAINE DERETOUR D’AIR MF13369

M24800

2

4

1

3

M24733

M29879

Page 44: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

MO

NTA

GE

12 Humidificateur 69-2413EF—05

Installation du régulateur de l’humidificateur

OPTION 2 : Installation à distance de l’humidistat H8908 (fourni) Si un régulateur différent est utilisé, consultez les instructions d’installation fournies avec le régulateur utilisé

Choisissez un emplacement dans une pièce habitable. Sélectionnez un emplacement à l’abri des courants d’air et d’une humidité excessive. Évitez le montage près de portes, de fenêtres, ou dans des salles de bains ou des cuisines.

Coupez un trou de 1 po de diamètre dans le mur pour le fil.

Acheminez un fil basse tension double ventilateur à l’emplacement de montage dans la pièce habitable.

Retirez le support de base de l’humidistat.

Poser la plaque de montage sur à l’emplacement choisi dans la pièce. Fixer au mur avec les deux vis de 25 mm (1 po) fournies.

M29952

M24721

2

2

4

1

M29948

M29949

3

Page 45: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

PL

OM

BE

RIE

13Humidificateur 69-2413EF—05

Raccords d’arrivée et de vidange d’eau

ÉTAPE 1 : Connexion de l’arrivée d’eau

Utilisez de l’eau chaude ou froide.

Coupez la canalisation d’eau de façon à ce qu’elle s’achemine de l’humidificateur à la prise d’arrivée d’eau principale

Insérez la canalisation d’eau dans le raccord rapide gris. Insérez-la entièrement, et tirez légèrement dessus pour vous assurer qu’elle est bien insérée.

Remarque : Le raccord rapide peut être retiré s’il est préférable d’utiliser un raccord de plomberie avec écrou de serrage en laiton de 1/4 po standard. Ne retirez pas le filtre conique si cette option est choisie.

ÉTAPE 2 : Raccord dans une canalisation d’eau• Consultez les codes locaux pour savoir comment

exécuter correctement les travaux de plomberie. • Utilisez la vanne à étrier fournie ou un raccord en T

et une vanne d’arrêt manuelle à installer dans une canalisation d’eau.

• Reportez-vous à la documentation incluse avec la vanne choisie et aux codes de plomberie locaux. Utilisez une technique convenant à la vanne.

• Branchez l’autre extrémité de la canalisation d’eau de l’humidificateur au robinet d’eau.

MCR32931

Vanne à étrierRaccord en T

Canalisation d’arrivée d’eau

Vanne d’arrêt manuelle

MF29605

2

1

Page 46: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

PL

OM

BE

RIE

ÉTAPE 3 : Raccord à la vidange d’eau• Consultez les codes de plomberie locaux pour

connaître la dimension du tuyau de vidange et les exigences de débit à respecter.

• La meilleure méthode d’installation consiste à se brancher directement dans le drain de plancher principal à l’aide du tuyau de caoutchouc fourni.

• Si aucun drain de plancher n’est disponible, consultez l’annexe B : Notions avancées de vidange.

Branchez le tuyau de vidange de 1/2 po fourni au raccord de vidange qui se trouve au bas de l’humidificateur.

Utilisez le collier de serrage de tuyau fourni pour fixer le tuyau de vidange au raccord.

Acheminez le tuyau de vidange jusqu’au drain de plancher. Le tuyau doit présenter une pente continue vers le bas.

Placez la sortie du tuyau dans le drain de plancher. Attachez le tuyau pour réduire le risque d’accumulation d’eau ou d’éclaboussures lorsque l’eau s’écoule de l’humidificateur.

HE300 UNIQUEMENT : Installation de la gaine de retourSi une gaine de retour doit être installée, un collecteur doit être installé dans le tuyau de vidange. Un vrai collecteur est recommandé, mais une boucle dans le tuyau fixée avec un ruban ou une attache est également acceptable.

MCR29881

Avant d’exécuter des travaux de câblage: J’ai connecté la canalisation d’arrivée d’eau à l’humidificateur et à la prise d’eau principale. J’ai installé le raccord de vidange. J’ai vérifié l’absence de fuites sur tous les raccords de plomberie.

4

3

2

1

M32929

14 Humidificateur 69-2413EF—05

Page 47: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

BL

AG

E

Quel modèle d’humidificateur ai-je en ma possession?Le numéro du modèle est situé au bas de l’humidificateur.

ÉTAPE 1 : Retrait du couvercle de l’humidificateur

Retirez le couvercle inférieur.

ÉTAPE 2 : Comprendre les bornes de câblage (HE150/HE250/HE300 uniquement)Borne de dérivation HE150/HE250

Gf : Utilisé pour forcer le ventilateur du système lorsque de l’humidité est requise.R : Entrée du R du système. Nécessaire pour alimenter le Gf lorsque le ventilateur est mis en marche forcée.Gt ou W : Entrée du G ou W du système. Nécessaire pour l’humidification uniquement lors des appels de chauffage ou de ventilateur du système.HUM : Contacts alimentés pour la régulation de l’humidité.C : Commun. Nécessaire pour l’entrée Gt ou W. Branchement au C du système.Power Out : Puissance de 24 V pour les régulateurs électriques.Power In : Alimentation du transformateur de 15 VA sur les modèles HE150/HE250 uniquement.SENSOR : Contacts alimentés pour un dispositif de vérification de la présence d’air lorsqu’utilisé.

MCR29935

MCR29937

Avant de raccorder l’humidificateur

Avant de câbler l’humidificateur : J’ai compris tous les codes et règlements de câblage en vigueur et je les appliquerai. Je lirai la section « Utilisation des commutateurs DIP » commençant à la page suivante.

MISE EN GARDE : Risque de haute tension.

Assurez-vous que l’humidificateur n’est pas branché avant de commencer le câblage.

1a

M29936

Borne de ventilateur HE300

MCR299501b

Humidificateur 69-2413EF—05 15

Page 48: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

BL

AG

E

Utilisation des commutateurs DIP (HE150/HE250/HE300 uniquement)Deux caractéristiques sont configurées par des réglages DIP qui sont décrits sous le couvercle de l’humidificateur.

ÉTAPE 3 : Comprendre les commutateurs DIP

DIP 1 (haut): Ce commutateur recherche les entrées du système de CVCA avant de permettre l’humidité. Réglé à gauche, l’humidificateur recherchera une/des entrée(s). Réglé à droite, il n’en recherchera pas.

DIP 2 (bas): Ce commutateur contrôle le ventilateur. Réglé à gauche, le système de CVCA contrôle le ventilateur. Réglé à droite, l’humidificateur force le ventilateur en marche lorsqu’il y a un appel d’humidité.

ÉTAPE 4 : Installation du transformateur (modèles à dérivation uniquement)Installez le transformateur à l’extérieur d’une boîte de jonction en métal mise à la masse en utilisant uniquement une entrée défonçable de 22 mm (7/8 po). Placez les languettes de montage dans l’entrée défonçable et serrez fermement la vis de serrage. Les raccords de câblage sur site et la mise à la masse du transformateur et du boîtier doivent être faits conformément au code électrique national (NEC) et au code électrique canadien (CEC). Branchez les fils sur le côté 120 V du transformateur.

Pour les modèles HE150 et HE250, le transformateur doit fournir une puissance constante aux bornes d’entrée de 24 V.

ÉTAPE 5 : Câblage de l’humidificateurUtilisez le schéma de câblage sur les pages suivantes adapté à votre équipement.Lorsque le câblage est complet, acheminez les fils sortant de l’humidificateur dans l’attache de câblage au bas de l’humidificateur.

MCR29882

Humidificateur 69-2413EF—0516

Page 49: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

BL

AG

E

Configuration du câblage : Modèles avancés (HE150/HE250/HE300)

Câblage du modèle H8908 pour humidifier uniquement avec appel de chauffage ou de ventilateur.

Câblage des modèles TrueIAQ, VisionPRO IAQ ou Prestige, en utilisant le régulateur intelligent pour programmer les appels d’humidité avec le chauffage, le refroidissement ou à la demande.

DISPOSITIF DE VÉRIFICATION DE PRÉSENCE D’AIR

LES MODÈLES HE150/HE250 UTILISENT UN TRANSFORMATEUR DE 15 VA CÂBLÉ DANS UNE ENTRÉE DE 24 V. LES MODÈLES HE100/HE200 UTILISENT UN TRANSFORMATEUR DE 10 VA CÂBLÉ DANS UNE ENTRÉE DE 24 V.

CONNECTEZ G POUR HUMIDIFIER EN CAS D’APPEL DU VENTILATEUR. CONNECTEZ W POUR HUMIDIFIER EN CAS D’APPEL DE CHALEUR. NE CONNECTEZ JAMAIS LES DEUX. CONNECTEZ C LORSQUE G OU W EST UTILISÉ.

UTILISEZ UN DISPOSITIF DE VÉRIFICATION DE PRÉSENCE D’AIR AU LIEU DE LA CONNEXION G/W POUR HUMIDIFIER À TOUT MOMENT LORSQUE LE VENTILATEUR FONCTIONNE.

1

3

2

LE MODÈLE HE300 UTILISE UNE PRISE SUR CORDON DE SECTEUR.

CONNECTEZ G POUR HUMIDIFIER EN CAS D’APPEL DU VENTILATEUR. CONNECTEZ W POUR HUMIDIFIER EN CAS D’APPEL DE CHALEUR. NE CONNECTEZ JAMAIS LES DEUX. CONNECTEZ C LORSQUE G OU W EST UTILISÉ.

UTILISEZ UN DISPOSITIF DE VÉRIFICATION DE PRÉSENCE D’AIR AU LIEU DE LA CONNEXION G/W POUR HUMIDIFIER À TOUT MOMENT LORSQUE LE VENTILATEUR FONCTIONNE.

1

3

2

ENTRÉE ÉLECTRIQUE

ENTRÉE ÉLECTRIQUE

HE150 OU HE250

RÉGLAGES DIP

HE300

H8908

10

OFF ON

20

30 40

50

60

MF29938A

G OU WC

OU DISPOSITIF DE VÉRIFICATION DE PRÉSENCE D’AIR

1

2 3

H8908

10

OFF ON

20

30 40

50

60

G OU W

C

1

2 3OU

ENTRÉE ÉLECTRIQUE

ENTRÉE ÉLECTRIQUE

LES MODÈLES HE150/HE250 UTILISENT UN TRANSFORMATEUR DE 15 VA CÂBLÉ DANS UNE ENTRÉE DE 24 V. LES MODÈLES HE100/HE200 UTILISENT UN TRANSFORMATEUR DE 10 VA CÂBLÉ DANS UNE ENTRÉE DE 24 V.

1

MF29939A

DU RÉGULATEUR D’HUMIDITÉ

HE150 OU HE250

RÉGLAGES DIP

HE300

1

LE MODÈLE HE300 UTILISE UNE PRISE SUR CORDON DE SECTEUR.1

DU RÉGULATEUR D’HUMIDITÉ

1

Humidificateur 69-2413EF—05 17

Page 50: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

BL

AG

E

Configuration du câblage : Modèles avancés (HE150/HE250/HE300)

Câblage pour forcer le ventilateur du système de CVCA dès que de l’humidité est requise (à la demande).

Câblage pour forcer le ventilateur et vérifier la présence d’air dans la gaine.

ENTRÉE ÉLECTRIQUE

ENTRÉE ÉLECTRIQUE

UNIQUEMENT REQUIS SUR LE THERMOSTAT DU SYSTÈME N’ISOLE PAS Y DE G. SI NÉCESSAIRE, COUPEZ LA CONNEXION DU G DU THERMOSTAT AU G DU SYSTÈME ET ACHEMINEZ PAR L’HUMIDIFICATEUR COMME ILLUSTRÉ. LES MODÈLES HE150/HE250 UTILISENT UN TRANSFORMATEUR DE 15 VA CÂBLÉ DANS UNE ENTRÉE DE 24 V. LES MODÈLES HE100/HE200 UTILISENT UN TRANSFORMATEUR DE 10 VA CÂBLÉ DANS UNE ENTRÉE DE 24 V.

1

2

UNIQUEMENT REQUIS SUR LE THERMOSTAT DU SYSTÈME N’ISOLE PAS Y DE G. SI NÉCESSAIRE, COUPEZ LA CONNEXION DU G DU THERMOSTAT AU G DU SYSTÈME ET ACHEMINEZ PAR L’HUMIDIFICATEUR COMME ILLUSTRÉ. LE MODÈLE HE300 UTILISE UNE PRISE SUR CORDON DE SECTEUR.

1

2

MF29940A

G (THERMOSTAT) 1

SORTIE DE 24 V POUR

HUMIDISTAT ÉLECTRONIQUE

HE150 OU HE250

RÉGLAGES DIP

HE300

2R

2

DU RÉGULATEUR D’HUMIDITÉ G (APPAREIL

DE CHAUFFAGE)G (APPAREIL DE CHAUFFAGE)

G (THERMOSTAT) 1

SORTIE DE 24 V POUR

HUMIDISTAT ÉLECTRONIQUE

RDU

RÉGULATEUR D’HUMIDITÉ

UNIQUEMENT REQUIS SUR LE THERMOSTAT DU SYSTÈME N’ISOLE PAS Y DE G. SI NÉCESSAIRE, COUPEZ LA CONNEXION DU G DU THERMOSTAT AU G DU SYSTÈME ET ACHEMINEZ PAR L’HUMIDIFICATEUR COMME ILLUSTRÉ. LES MODÈLES HE150/HE250 UTILISENT UN TRANSFORMATEUR DE 15 VA CÂBLÉ DANS UNE ENTRÉE DE 24 V. LES MODÈLES HE100/HE200 UTILISENT UN TRANSFORMATEUR DE 10 VA CÂBLÉ DANS UNE ENTRÉE DE 24 V.

1

2

UNIQUEMENT REQUIS SUR LE THERMOSTAT DU SYSTÈME N’ISOLE PAS Y DE G. SI NÉCESSAIRE, COUPEZ LA CONNEXION DU G DU THERMOSTAT AU G DU SYSTÈME ET ACHEMINEZ PAR L’HUMIDIFICATEUR COMME ILLUSTRÉ. LE MODÈLE HE300 UTILISE UNE PRISE SUR CORDON DE SECTEUR.

1

2

MF29941A

G (THERMOSTAT) 1

SORTIE DE 24 V POUR

HUMIDISTAT ÉLECTRONIQUE

HE150 OU HE250

RÉGLAGES DIP

HE300

2

R

2

DU RÉGULATEUR D’HUMIDITÉ

G (THERMOSTAT) 1

SORTIE DE 24 V POUR

HUMIDISTAT ÉLECTRONIQUE

RDU

RÉGULATEUR D’HUMIDITÉ

ENTRÉE ÉLECTRIQUE

ENTRÉE ÉLECTRIQUE

G (APPAREIL DE CHAUFFAGE)

G (APPAREIL DE CHAUFFAGE)

AFS AFS

Humidificateur 69-2413EF—0518

Page 51: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

BL

AG

E

Configuration du câblage : Modèles avancés (HE150/HE250/HE300)

Câblage du TrueEASE à l’équipement avec des bornes sous tension.

Câblage du TrueEASE à l’équipement avec des bornes sous tension.

AJOUTEZ UN RELAIS D’ISOLATION DE 24 V C.A. (TEL QUE LE R8222B1067) ENTRE L’HUMIDIFICATEUR ET LE SYSTÈME DE TRAITEMENT DE L'AIR.

UN COMMUTATEUR D’AÉRATION 50027910-001 (AFS) EST RECOMMANDÉ POUR GARANTIR UNE BONNE AÉRATION LORSQUE L’HUMIDIFICATEUR EST EN MARCHE. SI LE COMMUTATEUR AFS EST UTILISÉ, RÉGLEZ LE COMMUTATEUR DIP 1 SUR ARRÊT (GAUCHE).

LES MODÈLES HE150/HE250 UTILISENT UN TRANSFORMATEUR DE 15 VA CÂBLÉ DANS UNE ENTRÉE DE 24 V. LES MODÈLES HE100/HE200 UTILISENT UN TRANSFORMATEUR DE 10 VA CÂBLÉ DANS UNE ENTRÉE DE 24 V.

LE SCHÉMA DE CÂBLAGE SUPPOSE L’UTILISATION D’UN THERMOSTAT COMMUNIQUANT SPÉCIFIQUE À L’ÉQUIPEMENT POUR CONTRÔLER L’HUMIDIFICATEUR.

1

2

3

4

4 4

4

AJOUTEZ UN RELAIS D’ISOLATION DE 24 V C.A. (TEL QUE LE R8222B1067) ENTRE L’HUMIDIFICATEUR ET LE SYSTÈME DE TRAITEMENT DE L'AIR.

UN COMMUTATEUR D’AÉRATION 50027910-001 (AFS) EST RECOMMANDÉ POUR GARANTIR UNE BONNE AÉRATION LORSQUE L’HUMIDIFICATEUR EST EN MARCHE. SI LE COMMUTATEUR AFS EST UTILISÉ, RÉGLEZ LE COMMUTATEUR DIP 1 SUR ARRÊT (GAUCHE).

LE MODÈLE HE300 UTILISE UNE PRISE SUR CORDON DE SECTEUR.

LE SCHÉMA DE CÂBLAGE SUPPOSE L’UTILISATION D’UN THERMOSTAT COMMUNIQUANT SPÉCIFIQUE À L’ÉQUIPEMENT POUR CONTRÔLER L’HUMIDIFICATEUR.

1

2

3

MF33040

COM HUM R G

HE150 OU HE250 HE300

31 1

2

2

3

AFS AFS

COM HUM R G

RÉGLAGES DIP

ENTRÉE ÉLECTRIQUE

ENTRÉE ÉLECTRIQUE

MF33039

HUMIDIFICATEUR

FIL DE SORTIE DE SOLÉNOÏDE (EAU)

COM

HUM

R

G

LE SCHÉMA DE CÂBLAGE SUPPOSE L’UTILISATION D’UN THERMOSTAT COMMUNIQUANT SPÉCIFIQUE À L’ÉQUIPEMENT POUR CONTRÔLER L’HUMIDIFICATEUR.

1

1

Configuration du câblage : Modèles de base (HE100/HE200)

Humidificateur 69-2413EF—05 19

Page 52: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

BL

AG

E

Configuration du câblage : Modèles de base (HE100/HE200)

Câblage du modèle H8908 avec verrouillage de ventilateur.

Câblage du modèle H8908 avec moteur de ventilateur deux vitesses.

1

2

MOTEUR DE VENTILATEUR 2 VITESSES

RELAIS DE COMMUTATION BIPOLAIRE UNIDIRECTIONNEL

RÉGULATEUR DE VENTILATEUR L2

TRANSFORMATEUR

L1(CHAUD)

ALIMENTATION

ALIMENTATION. FOURNISSEZ AU BESOIN UN DISPOSITIF DE COUPURE ET UNE PROTECTION CONTRE LES SURCHARGES.

CÂBLAGE DE 24 V C.A.

1

H L

C

2

MF29942A

POWERSUPPLY

H8908

10

OFF ON

20

30 40

50

60

HUMIDIFICATEUR

FIL DE SORTIEDE SOLÉNOÏDE (EAU)

1

2

ALIMENTATION. FOURNISSEZ AU BESOIN UN DISPOSITIF DE COUPURE ET UNE PROTECTION CONTRE LES SURCHARGES.

CÂBLAGE DE 24 V C.A.

TRANSFORMATEUR

MOTEUR DE VENTILATEUR D’APPAREIL DE CHAUFFAGE

RÉGULATEUR DE VENTILATEUR

L1(CHAUD)

L2

ALIMENTATION

H8908

1

2

HUMIDIFICATEUR

MF29945A

10

OFF ON

20

30 40

50

60

FIL DE SORTIEDE SOLÉNOÏDE (EAU)

Humidificateur 69-2413EF—0520

Page 53: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

BL

AG

E

Configuration du câblage : Modèles de base (HE100/HE200)

Câblage du modèle H8908 avec relais à détection de courant.

Câblage en ligne du modèle H8908 avec dispositif de vérification de présence d’air.

1

2

ALIMENTATION. FOURNISSEZ AU BESOIN UN DISPOSITIF DE COUPURE ET UNE PROTECTION CONTRE LES SURCHARGES.

CÂBLAGE DE 24 V.

TRANSFORMATEUR

RELAIS DE DÉTECTION DE COURANT

MF29943A

L1 (CHAUD)

L2 1

2

CLO

HI

H8908

10

OFF ON

20

30 40

50

60

HUMIDIFICATEUR

FIL DE SORTIEDE SOLÉNOÏDE (EAU)

1

2

DISPOSITIF DE VÉRIFICATION DE PRÉSENCE D’AIR

ALIMENTATION. FOURNISSEZ AU BESOIN UN DISPOSITIF DE COUPURE ET UNE PROTECTION CONTRE LES SURCHARGES.

CÂBLAGE DE 24 V.

TRANSFORMATEUR

HUMIDIFICATEUR

MF29944A

L1 (CHAUD)

L21

2

H8908

10

OFF ON

20

30 40

50

60

FIL DE SORTIEDE SOLÉNOÏDE (EAU)

Humidificateur 69-2413EF—05 21

Page 54: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

FO

NC

TIO

NN

EM

EN

T

ET

PAR

AT

ION

Une fois l’installation terminée, suivez les étapes ci-dessous. Assurez-vous que l’humidificateur fonctionne correctement avant que le propriétaire ne prenne possession du système. Une fois l’humidificateur en marche, le fonctionnement quotidien est automatique. Le propriétaire de la maison peut utiliser le régulateur pour régler les niveaux d’humidité et allumer ou couper l’humidificateur.

Enclenchez le couvercle inférieur en place.

Rétablissez l’arrivée d’eau au niveau de la vanne à étrier ou du raccord en T et du robinet d’arrêt manuel. L’eau s’écoule vers l’humidificateur mais ne passe pas par le tampon tant que le régulateur d’humidité n’est pas en marche.

Branchez l’humidificateur (HE300) ou alimentez le système de CVCA (HE100/HE150/HE200/HE250)• Sur les modèles avancés, les voyants DEL clignotent

pendant 3 à 5 secondes pour vérifier que le système est alimenté.

Sur les modèles HE100/HE200, mettez le bouton de position du registre sur la prise de dérivation pour qu’il soit parallèle à la prise de dérivation. Sur les modèles HE150/HE250, l’humidificateur effectue automatiquement cette étape. Non applicable sur les modèles HE300.

Mettez le régulateur d’humidité en marche.• Si le câblage est configuré pour un fonctionnement

avec chauffage ou ventilateur uniquement, faites les demandes de système appropriées pour permettre l’humidification.

• Assurez-vous que l’air souffle par le réseau de gaines lors de l’appel à l’humidificateur.

Le voyant d’humidification s’allume en continu lorsque l’eau passe par le tampon de l’humidificateur.• Sur les modèles HE150/HE250, retirez le couvercle

supérieur de l’humidificateur pour vérifier que le débit d’eau passe par le plateau supérieur et dans le tampon. Assurez-vous que le registre tourne en position ouverte lorsque l’humidification est en marche, et tourne en position fermée lorsque l’humidification est arrêtée.

• Sur les modèles HE300, vérifiez que de l’eau sort du tuyau d’évacuation.

MCR29884

Démarrage et vérification

Vérifiez tous les raccords des canalisations d’eau et de vidange pour vous assurer de l’absence de fuites avant de quitter l’emplacement d’exécution des travaux.

3

2

1

4

5

6

• Vérifiez l’absence de fuite immédiatement après avoir ouvert l’arrivée d’eau principale, puis après 15 minutes de fonctionnement de l’humidificateur.

Réglez le point de consigne au niveau désiré une fois les tests terminés. Si aucune humidité n’est requise, mettez le régulateur sur la position Arrêt et tournez le bouton de position du registre sur la sortie de dérivation perpendiculairement à la sortie de dérivation (HE100/HE200 uniquement).

Humidificateur 69-2413EF—0522

Page 55: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

FO

NC

TIO

NN

EM

EN

T

ET

PAR

AT

ION

Il est recommandé de remplacer le tampon de l’humidificateur une fois par an. Ceci peut être fait au début ou à la fin de la saison sèche. La conception de l’humidificateur permet de procéder facilement et rapidement au remplacement, car l’accès au tampon se fait en une seule étape.

Entretien de routine

Dérivation :

1a. Le tampon peut être remplacé par le côté en saisissant la poignée noire et en tirant, ou par l’avant en retirant le couvercle supérieur de l’humidificateur et en basculant le tampon vers l’avant et vers l’extérieur. Le tampon peut être retiré de l’autre côté de l’humidificateur, en fonction de l’installation.

MCR29885

25%

Ventilateur:

1b. Le tampon peut être remplacé par l’avant en saisissant la poignée noire et en la tirant vers l’extérieur.

MCR29886

2. Retirez le plateau en haut du tampon et essuyez-le pour retirer tout sédiment présent.3. Remplacez l’ancien tampon par un neuf, en vous assurant qu’il est correctement orienté (consultez la boîte

du tampon). Essuyez tout sédiment présent à l’intérieur du cadre du tampon.4. Insérez de nouveau le plateau en haut du tampon avec les flèches à l’intérieur du plateau pointant dans la

gaine. Réinsérez ensuite le cadre dans l’humidificateur.5. Une fois le remplacement effectué, retirez le couvercle inférieur et appuyez sur le bouton RESET

(Réinitialiser) pour réinitialiser la minuterie d’entretien.

21

Humidificateur 69-2413EF—05 23

Page 56: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

FO

NC

TIO

NN

EM

EN

T

ET

PAR

AT

ION

Problème Raisons Solutions

Basse humidité La soufflante de l’appareil de

chauffage ne fonctionne pas

1. Réenclenchez votre disjoncteur ou recherchez un fusible grillé.

2. Assurez-vous que l’appareil de chauffage est alimenté en courant.

3. Vérifiez tous les raccords de câblage externes.

4. Vérifiez le réglage du régulateur d’humidité.

Changements d’air rapides ou

courants d’air

1. Gardez les portes et les fenêtres fermées.

2. Fermez le registre du foyer s’il n’est pas utilisé.

3. Limitez l’utilisation du ventilateur d’échappement.

4. Étanchéisez le pourtour des portes et des fenêtres.

Haute humidité Condensation sur les murs 1. Coupez le régulateur d’humidité et l’eau jusqu’à ce que la

condensation ait disparu.

Forte condensation sur les

fenêtres

1. Réduisez le régulateur d’humidité de façon à éliminer la

condensation créée par l’humidité. Si l’humidité persiste, le domicile

doit être mieux ventilé.

Le voyant de

remplacement

du tampon est

allumé (HE150/

HE250/HE300)

Ceci est le rappel annuel

indiquant qu’il faut remplacer le

tampon dans l’humidificateur

1. Consultez la liste des pièces et remplacez le tampon correspondant

au modèle d’humidificateur utilisé.

2. Une fois le tampon remplacé, appuyez sur le bouton RESET

(Réinitialiser) sous le couvercle.

Le voyant

d’entretien est

allumé (HE150/

HE250)

Le registre à l’intérieur de

la dérivation ne s’est pas

complètement ouvert

1. Appuyez sur le bouton RESET (Réinitialiser) sous le couvercle.

2. Vérifiez que la prise du registre est connectée sur le côté de

l’humidificateur comportant la sortie de dérivation.

3. Assurez-vous qu’il n’y a pas d’interférence provenant des vis à tôles

raccordant la dérivation à la gaine.

4. Si la panne persiste, remplacez le moteur du registre de dérivation.

Le dispositif de vérification de

présence d’air a détecté une

absence de mouvement d’air.

Uniquement possible si les

commutateurs

DIP sont configurés

de la façon suivante :

1. Vérifiez le câblage au commutateur de débit d’air.

2. Confirmez que la configuration des commutateurs DIP et le câblage

de l’humidificateur sont corrects.

3. Vérifiez l’emplacement du commutateur de débit d’air pour vous

assurer qu’il est correctement placé dans la gaine pour détecter l’air.

4. Vérifiez les relais des commutateurs.

5. Si la panne persiste, remplacez le commutateur de débit d’air.

Le voyant

d’entretien est

allumé (HE300)

Panne du moteur du ventilateur 1. Appuyez sur le bouton RESET (Réinitialiser) sous le couvercle.

2. Débranchez et rebranchez l’humidificateur.

3. 3. Si la panne persiste, remplacez le moteur.

Le dispositif de vérification de

présence d’air a détecté une

absence de mouvement d’air.

Uniquement possible si les

commutateurs

DIP sont configurés

de la façon suivante :

1. Vérifiez le câblage au commutateur de débit d’air.

2. Confirmez que la configuration des commutateurs DIP et le câblage

de l’humidificateur sont corrects.

3. Vérifiez l’emplacement du commutateur de débit d’air pour vous

assurer qu’il est correctement placé dans la gaine pour détecter l’air.

4. Vérifiez les relais des commutateurs.

5. Si la panne persiste, remplacez le commutateur de débit d’air.

Dépannage

Humidificateur 69-2413EF—0524

Page 57: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

FO

NC

TIO

NN

EM

EN

T

ET

PAR

AT

ION

Humidificateur 69-2413EF—05 25

Capacité d’humidification

À une température de plénum de 49 °C (120 °F) et une chute

de pression statique de 0,20 sur l’arrivée et le retour :

HE100/150 : Jusqu’à 46 litres/jour (12 gallons/jour)

HE200/250 : Jusqu’à 65 l/jour (17 gal/jour)

HE300 : Jusqu’à 68 l/jour (18 gal./jour)

Volume humidifié

HE100/150 : Jusqu’à 16 000 pieds cubes

HE200/250 : Jusqu’à 20 000 pieds cubes

HE300 : Jusqu’à 24 000 pieds cubes

Dimensions

HE100/150: 268 mm (l) x 356 mm (h) x 257 mm (p)

14,5 po (l) x 14 po (h) x 10,1 po (p)

HE200/250: 381 mm (l) x 436 mm (h) x 257 mm (p)

15 po (l) x 17,15 po (h) x 10,1 po (p)

HE300: 394 mm (l) x 427 mm (h) x 262 mm (p)

15,5 po (l) x 16,8 po (h) x 10,3 po (p)

Dimensions du tampon de l’humidificateur

HE100/150 : 241 mm (l) x 249 mm (h) x 38 mm (p)

9-1/2 po (l) x 9-13/16 po (h) x 1-1/2 po (p)

HE200/250 : 254 mm (l) x 330 mm (h) x 38 mm (p)

10 po (l) x 13 po (h) x 1-1/2 po (p)

HE300 : 254 mm (l) x 330 mm (h) x 38 mm (p)

10 po (l) x 13 po (h) x 1-1/2 po (p)

Pression statique

HE100/150/: Assurez une pression statique dans le plénum

200/250 de 0,3 po c.e. max.

HE300: Assurez une pression statique dans le plénum

de 0,4 po c.e. max.

Dimensions de l’ouverture du plénum

HE100/150 : 238 mm (l) x 241 mm (h)

9-5/16 po (l) x 9-7/16 po (h)

HE200/250 : 248 mm (l) x 321 mm (h)

9-3/4 po (l) x 12-5/8 po (h)

HE300 : 343 mm (l) x 357 mm (h)

13-1/2 po (l) x 14-1/16 po (h)

Dimensions de l’ouverture de la gaine de dérivation

(HE100/150/200/250)

152 mm (6 po)

Plages de fonctionnement

1,1 ºC–32 ºC (34 ºF–90 ºF)

Humidité : 0 à 95 % d’HR, sans condensation

Raccord de vidange

Tuyau en plastique de 13 mm (1/2 po) de dia. ext.

directement connecté au raccord de vidange sur l’unité.

Tensions nominales et tolérances

HE100/200 : 24 V c.a., 60 Hz, 0,5 A maximum

HE150/250 : 24 V c.a., 60 Hz, 0,75 A maximum

HE300 : 120 V c.a., 60 Hz, 1 A max.

A : Spécifications

Page 58: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

AN

NE

XE

S

Humidificateur 69-2413EF—0526

B :

Not

ions

ava

ncée

s de

vid

ange

Opt

ion

1 : L

a pl

ombe

rie p

our v

idan

ger

la p

ompe

à c

onde

nsat

s

• Po

mpe

(cap

acité

de

tem

péra

ture

de

140

°F, d

ébit

de p

ompe

nom

inal

>5

gal./

h et

aug

men

tatio

n de

9 p

ieds

).•

La p

ompe

doi

t être

alim

enté

e lo

rsqu

e de

l’hu

mid

ifica

teur

fonc

tionn

e.•

Util

isez

une

pom

pe d

otée

d’u

n dé

tect

eur d

e dé

bord

emen

t

inté

gré

ou in

stal

lez

la p

ompe

dan

s un

pla

teau

d’é

coul

emen

t

avec

un

com

mut

ateu

r hum

ide

pour

met

tre d

e l’h

umid

ifica

teur

hors

fonc

tion.

• Su

ppor

tez

le tu

yau

de c

aout

chou

c à

tous

les

6 po

• Le

PVC

doi

t être

d’u

n ca

libre

40

ou p

lus.

• To

us le

s jo

ints

des

tuya

ux d

e pl

astiq

ue s

ont s

oudé

s.•

Vida

ngez

dan

s un

sip

hon

P qu

i res

tera

mou

illé e

n to

ut te

mps

.

SIPH

ON

MIN

IMU

M D

E 1

1/2

PO

(OU

DIM

ENSI

ON

EXI

GÉE

PAR

LE

CO

DE

LOC

ALE)

VEN

TILÉ

SEL

ON

LE

CO

DE

LOC

AL

TOU

S LE

S JO

INTS

D

ES T

UYA

UX

DE

PLAS

TIQ

UE

SON

T SO

UD

ÉS

MN

PT 1

/2 P

O x

SO

UD

ÉFN

PT 1

/2 P

O X

1 1

/2 P

O P

VC

PVC

1 1

/2 P

OTU

YAU

PVC

DE

1/2

PO (M

INIM

UM

)

FNPT

1/2

PO

X P

VC 1

1/2

PO

MN

PT 1

/2 P

O X

CPC

V 1/

2 PO

FNPT

1/2

PO

X 1

1/2

PO

PVC

CO

LLIE

R D

E SE

RR

AGE

DU

TU

YAU

CO

LLIE

R D

E SE

RR

AGE

DU

TU

YAU

CO

LLIE

R D

E SE

RR

AGE

DU

TU

YAU

CAN

NEL

É D

E 1/

2 PO

x M

NPT

DE

1/2

PO

DIM

ENSI

ON

PO

UR

ASS

UR

ER L

A C

OM

PATI

BILI

TÉ A

VEC

LA

SOR

TIE

DE

LA P

OM

PE

Opt

ion

2 : P

lom

berie

ver

s un

sip

hon

dédi

é.

CO

LLIE

RS

DE

SER

RAG

E À

TOU

TES

LES

CO

NN

EXIO

NS

TUBE

DE

3/8

PO D

’UN

E C

APAC

ITÉ

THER

MIQ

UE

NO

MIN

ALE

DE

212

°F

FNPT

3/4

PO

X C

PCV

3/4

PO

TUYA

U C

PVC

DE

3/4

POVE

RS

POM

PE

AUTR

E TU

YAU

DE

HU

MID

IFIC

ATEU

R

POU

R T

OU

TES

LES

OPT

ION

S IL

LUST

RÉE

S :

MN

PT 1

/2 P

O x

SO

UD

É

FNPT

1/2

PO

X 1

1/2

PO

PVC

PVC

1 1

/2 P

O

TUYA

U P

VC D

E 1/

2 PO

(MIN

IMU

M)

FNPT

1/2

PO

X 1

1/2

PO

PVC

MN

PT 1

/2 P

O X

CPC

V 1/

2 PO

FNPT

1/2

PO

X 1

1/2

PO

PVC

CAN

NEL

É D

E 1/

2 PO

x M

NPT

DE

1/2

PO

MFC

R29

888

TOU

S LE

S R

ACC

OR

DS

DE

L’ÉL

ECTR

OVA

NN

E VE

RS

LE S

IPH

ON

D

E VI

DAN

GE

SON

T SC

ELLÉ

S

ÉVIE

R

T EN

PVC

D

E 1

1/2

PO

1-1/

2 PO

PVC

1-1/

2 IN

.PV

C

ACC

OU

PLEM

ENT

SOU

SOU

RAC

CO

RD

À B

AND

E À

FEN

TES

EN A

CIE

R IN

OXY

DAB

LE

DIM

ENSI

ON

NÉS

PO

UR

ÊT

RE

CO

MPA

TIBL

E AV

EC

LE T

UYA

U (C

UIV

RE,

PVC

, C

PCV)

DIM

ENSI

ON

CO

MPA

TIBL

E SO

RTI

E D

E PO

MPE SO

LUTI

ON

DE

REC

HAN

GE

CET

TE C

ON

FIG

UR

ATIO

N

PER

MET

LA

DÉP

OSE

DU

SIP

HO

N

FILE

TS

ACC

OU

PLEM

ENT

FILE

TS

FILE

TS

SOU

Opt

ion

4 : P

lom

berie

ver

s un

sip

hon

d’év

ier.

MN

PT 1

/2 P

O x

SO

UD

ÉFN

PT 1

/2 P

O X

1 1

/2 P

O P

VC

1/2

PO P

VC

TUYA

U P

VC D

E 1/

2 PO

(MIN

IMU

M)

FNPT

1/2

PO

X 1

1/2

PO

PVC

MN

PT 1

/2 P

O X

CPC

V 1/

2 PO

FNPT

3/4

PO

X P

VC 1

1/2

PO

CAN

NEL

É 3/

4 PO

x M

NPT

3/4

PO

TOU

S LE

S TU

YAU

X EN

PLA

STIQ

UE

SOU

S L’

ÉVIE

R, P

VC M

INIM

UM

DE

1 1/

2 PO

TOU

S LE

S R

ACC

OR

DS

DE

L’ÉL

ECTR

OVA

NN

E VE

RS

LE S

IPH

ON

DE

VID

ANG

E SO

NT

SCEL

LÉS

ÉVIE

R

SOU

SOU

LD

SOU

DIV

ISIO

N E

N Y

SOLU

TIO

N D

E R

ECH

ANG

EC

ETTE

CO

NFI

GU

RAT

ION

PE

RM

ET L

A D

ÉPO

SE D

U S

IPH

ON

DIM

ENSI

ON

PO

UR

ASS

UR

ER L

A C

OM

PATI

BILI

TÉ A

VEC

LA

SOR

TIE

DE

LA P

OM

PE

Opt

ion

3 : P

lom

berie

ver

s l’é

vier

ave

c un

sip

hon

dédi

é

TUYA

U D

E C

UIV

RE

DE

1/2

POFN

PT 1

/2 P

O x

SO

UD

É

CO

LLIE

RS

DE

SER

RAG

E D

U T

UYA

U

TUYA

U D

E L’

HU

MID

IFIC

ATEU

R

TEM

P. N

OM

INAL

E 14

0 °F

, DÉB

IT

DE

POM

PE >

5 G

AL./H

AVE

C

AUG

MEN

TATI

ON

DE

9 PI

EDS

CAN

NEL

É D

E 1/

2 PO

x

MN

PT D

E 1/

2 PO

TUYA

U

FLEX

IBLE

ÉTAN

CH

ÉISE

Z TO

US

LES

RAC

CO

RD

S D

E L’

ÉLEC

TRO

VAN

NE

VER

S LA

C

OLO

NN

E D

E VI

DAN

GE

FNPT

1/2

PO

X

PVC

1/2

PO

TUYA

U P

VC D

E 1/

2 PO

(MIN

IMU

M)

FNPT

1/2

PO

X C

PCV

1/2

PO

TUYA

U D

E C

PVC

DE

1/2

PO

TUBE

DE

1/2

PO

D’U

NE

CAP

ACIT

É TH

ERM

IQU

E N

OM

INAL

E D

E 14

0 °F

Bran

chez

à l’

hum

idifi

cate

ur.

Com

mun

à to

utes

les

optio

ns d

e pl

ombe

rie.

RAC

CO

RD

À B

AND

E À

FEN

TES

EN A

CIE

R

INO

XYD

ABLE

D

IMEN

SIO

NN

ÉS P

OU

R

ÊTR

E C

OM

PATI

BLE

AVEC

LE

TUYA

U

(CU

IVR

E, P

VC, C

PCV)

SOU

1-1/

2 IN

. PVC

Page 59: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

AN

NE

XE

S

Humidificateur 69-2413EF—05 27

M29951

16

17

18

19

M32932

x 25

x 25LO

AD

R

C

3 4

5 6

89

7

21 11

10

12

13 14

15

20 21

22

23

C : Liste des pièces

Page 60: TrueEASE™ Humidification System · Ensure proper clearances from the air-conditioning coil inside the duct. NOTE: The HE300 Fan model extends into the duct 1-3/4 inch. Bypass models

Solutions de régulation et d’automatisation

Honeywell International Inc.

1985 Douglas Drive North

Golden Valley, MN 55422

http://yourhome.honeywell.com

® Marque de commerce déposée aux É.-U.© 2011 Honeywell International Inc.69-2413EF—05 M.S. Rev. 07-11Imprimé aux États-Unis

Référence à la figure

Référence de pièce Description de la pièce Utilisez avec le modèle

N/A HC26E1004 Grand tampon de rechange avec revêtement AgION HE200, HE250. HE300

N/A HC26A1008 Grand tampon de rechange standard HE200, HE250, HE300

N/A HC22E1003 Petit tampon de rechange avec revêtement AgION HE100, HE150

N/A HC22A1007 Petit tampon de rechange standard HE100, HE150

N/A 32001616-001 Vanne à étrier HE100, HE150, HE200,

HE250, HE300

1 50041883-002 Électrovanne c.a. HE100, HE200

2 50041883-001 Électrovanne c.c. HE150, HE250, HE300

3 50041861-001 Cadre et plateau pour petits modèles à dérivation HE100, HE200

4 50041861-002 Cadre et plateau pour grands modèles à dérivation HE150, HE250

5 50052641-001 Couvercle supérieur pour petits modèles à dérivation HE100, HE150

6 50052641-002 Couvercle supérieur pour grands modèles à dérivation HE200, HE250

7 50041888-001 Petite gaine de dérivation avec registre manuel HE100

8 50041888-002 Grande gaine de dérivation avec registre manuel HE200

9 50041890-001 Petite gaine de dérivation avec registre automatique HE150

10 50041890-002 Grande gaine de dérivation avec registre automatique HE250

11 50041886-001 Couvercle inférieur pour petits modèles à dérivation de base HE100

12 50041887-001 Couvercle inférieur pour grands modèles à dérivation de base HE200

13 50052642-001 Couvercle inférieur pour petits modèles à dérivation avancés HE150

14 50052642-002 Couvercle inférieur pour grands modèles à dérivation avancés HE250

15 50057547-002 Carte de circuit pour HE150 HE150

50057547-003 Carte de circuit pour HE250 HE250

16 50045729-001 Soufflante et moteur avec isolateur HE300

17 50057547-001 Carte de circuit pour HE300 HE300

18 50041919-001 Cadre et plateau pour modèles à ventilateur HE300

19 50052653-001 Couvercle de cosses pour modèles à ventilateur HE300

20 32001652-001 Transformateur 10 V HE100, HE200

21 50050349-001 Transformateur 15V HE150, HE250

22 50032048-002 Qté 25 Adaptateur à connexion rapide pour humidificateur résidentiel HE100, HE150, HE200,

HE250, HE300

23 32001647-001 Qté 25 Filtre conique pour humidificateur résidentiel HE100, HE150, HE200,

HE250, HE300