SWIMMING POOLHEAT PUMP UNIT
Installation & Instruction Manual
R407C
Model T50HHDTBNA
rev 9/4/07
Contents
SWIMMING POOL HEAT PUMP
Performance Data Specifications
1. Performance data 1
2. Dimensions 2
3.The display
4. Wiring diagram
Service
3
8
1. How to Obtain Service 9
Attachments
1. The charts displayed for outdoor pools & indoor pools 10
132. The Installation With Chlorinator
3. Conversion Tables 14
31
Specifications
Measurement conditions:
Outdoor air temp: 24°C to 19°C, inlet water temp: 27°C, ambient temp range: 0~35°C
Performance Data of Swimming Pool Heat Pump Unit
SWIMMING POOL HEAT PUMP
Input power heating
Running current heating
COP
Power supply
Number of compressors
Compressor
Number of fans
Input power of fan
Fan rotation speed
Noise
Water connection size
Water flow
Water pressure drop
Refrigerant(R407C)
W
BTU/h
W
A
V/PH/HZ
W
RPM
dB(A)
inch
m /h
Kpa
Kg
mm
mm
Kg
3
TH50HHDTBNA
11300
38500
2306
10.6
4.9
220V/1PH/50HZ
1
Rotary
1
200
830
60
1-1/2”
4-7
15
2.3
660
660
850
780
820
1040
87
93
Code
Rated heating capacity
Net dimension
Shipping
dimension
Weight
L
W
H
L
W
H
Net weight
Gross weight
SWIMMING POOL HEAT PUMP
32
The dimensions for Swimming Pool Heat Pump Unit- Monobloc
660
66
0 85
08
03
70
Power wiring specs
Code
Specs 4mm2
Power supply installation condition: Thus a breaker with more than 3mm touching point space.
TH50HHDTBNA
33
SWIMMING POOL HEAT PUMP
1)The functions of the wire controller
12
MINTEMP
ON
OFF
%
h
%C FC F
AUTO
hMIN
INSET VALVEOUTROOMNO.
HUM
FAN
AUX
Initialization
Press to turnon and turn offthe units.
Press buttonto change modes
MPress to set operationparameter under stand bystatus, or check the operationparameter under runningor stand by status.
Set Press to startauxiliary electrical heating
AUX
2)How to set operation parameter:
Standby status, press “SET” button to enter Operation Parameter setting interface;
Press “SET” again to start setting (parameter from 00-1
(see the Operation Parameter Table page-5);
Under parameter setting, parameter 00-01can be set by pressing or ;
02-10 must be set only after pressing and at the same time for 3s, get a
sound of “Beep” to unlock. Data will be stored in 3s without any press on the
controller. Parameter 02-10 must be adjusted by professional technicians.
Please note no press in 5s, the LCD will display water-in/water out temp.
(under running) or ambient temp. (Under standby status)
Whilst running , you can press “SET” to check current parameter, but data of
parameter can not be changed !
Remarks: Standby status means the unit is connected with electricity but not running .
Parameter 00-10 can only be changed under standby status!
C
ROOM
AUX
C
NO.
AUX
Parameter 01
to set inlet water temp under
heating mode (15-40°C) default
setting: 40°C
NO.
AUX
Parameter 02Total working time ofcompressor after frosting
MIN
Stand by statusThe LCD display ambienttemp. And current mode
C
NO.
AUX
Parameter 00
to set inlet water temp. under
cooling mode (8-28 °C) default
setting:12° C
TEMP
SET SET SET
SWIMMING POOL HEAT PUMP
34
NO.
AUX
Parameter 06System Quantity
VALVENO.
AUX
NO.
AUX
Parameter 07Save settingafter power failure1(yes) 0(No)
NO.
AUX
Parameter 08Mode:1 (cooling&heating)2 auxiliary elec heating
(cooling+heating)3 (heating only)
VALVENO.
AUX
NO.
AUX
" "
" "
" ".
0 long time working forwater pump
1 water pump turns offafter the whole unit poweroff for 30s
initialization 0
C
NO.
AUX
Parameter 03Setting initialization temp fordefrosting -7°C - not display,range(0- -30°C)
" ", (" "
C
NO.
AUX
35
Parameter 04Terms of Exit DefrostingFunction (2-30°C)default setting:13°C
NO.
AUX
MIN
35
Parameter 05Max. Time of defrosting
(1-12min)Default setting: 8min.
C
VALVENO.
AUX
C
NO.
AUX
Auto mode
default setting:
temp 30 C°
SET SET SET
SET SET SET
SET SET
The unit's operation data can be set on the wire controller.Please set according to the below:table
Digit
00
01
02
03
04
05
06
07
08
MeaningReturn water temp.Setting (cooling mode)
Total working time ofcompressor after frosting
Terms of exit defrostunder heating model
System quantity
Automatic restarting
Model (cooling only/heat pump/auxiliary electrical heating/hot water)
Range
8-30°C
15-40°C
30-90MIN
0--30°C
2-30°C
1-12MIN
1-2
0-1
1-3
Default
12°C
27°C
-7°C
40MIN
13°C
8 MIN
2
0 (no recording)
3 (hot water)
Adjust(yes/no)
Return water temp.Setting (heating mode)
Setting initialization temp fordefrosting
Time of exit defrostunder heating model
No
Yes
Yes
09
10
0
30°C
0-1
8-40
Working mode of water pump
Auto mode (return water temp )
Yes
Yes
Yes
No
Yes
No
No
No
SWIMMING POOL HEAT PUMP
35
3)How to know the current status?
15
Under running status , press and to check the current status
of the unit! You can check water-in/water out temp, condenser temp
and ambient temp, please note no motion on the display for 5s, the
LCD will display water-in/water out temp/(under running) or ambient
temp. (unit stops)C
AUX
Condenser 2 temp.
C
AUX
ROOM
Ambient temp.
C
AUX
Condenser 1 temp.
CC
IN OUT
AUX
Water temp.of inlet/outlet
TEMP TEMP
°C
MalfunctionWireController
Water in temp.Sensor failure
Coil1 sensor failure
Temp. differential is too largebetween water-in andwater-out
Defrostingunder cooling mode
The second time freezingprotection in winter
Malfunction of system1
Flow switch failure
Power supply connectionswrong (for 3phase unit)Hi/Low pressure protection(for single phase unit)
Defrosting
Communication failure
PP 01
PP 02
PP 03
PP 04
PP 05
PP 06
PP 07
PP 08
PP 09
EE 01
EE 02
EE 03
EE 05
Defrost codedisplay
EE 08
Reason
The sensor is openor short circuit
Check or change the sensor
Water flow volume notenough, water pressuredifference is too low
Check the water flow volume,or clogged plumbing system
The system1 protectionwas failure
Resolution
Wire controller and ThePCB connection failure
Check the wire connection
Wrong connections orlack of connection
Check each protection point of system1remove the malfunction according toSystem Protection Board malfunction table.
Insufficient water flow
Too low
No water/little waterin water system.
Check the water flow volume,or clogged plumbing system
Check connections of power cableEE 04
Water out temp.Sensor failure
The sensor is openor short circuit
Check or change the sensor
The sensor is openor short circuit
Check or change the sensor
Coil 2 sensor failure(proprietary for A type)
The sensor is openor short circuit
Check or change the sensor
Ambient sensor failure The sensor is openor short circuit
Check or change the sensor
Check the water flow volume,or clogged plumbing system
The first time freezingprotection in winter
Too low
Malfunction of system2 (cutoff under low voltage)
The system2 protectionwas failure
Check each protection point of system2remove the malfunction according toSystem Protection Board malfunction table.
3 times water-in andwater-out temp.difference protectionin 30 minutes
Check the water flow volume,or clogged plumbing system
Insufficient water flow or waterpressure difference is too little
SWIMMING POOL HEAT PUMP
36
4)Controller lock.
5)Troubleshooting
C
ROOM
AUX
TEMPTEMP
CC
IN OUT
AUX
Under running or standby status press and at the same time for 5s, controller willbe locked, display as above. Press and again for 5s for unlocking.
Running statusStand by status
Connection of PCB illustration
Connections explanation:
1
2
3
4
5
6
7
8
9
10
11
HI FAN High speed for fan
PUMP Water pump (220VAC)
FAN Fan motor (220VAC)
VAL2 4way valve of system2 (220VAC) (no use)
COMP2
Live wire
KYOUT GND On/Off switch (output) (no use)
HI F
AN
GN
D
GN
D
12
V
GN
D
GN
D
GN
D
GN
D
12
V
Chiller 300
PU
MP
FA
N
VA
L2
VA
L1
CO
MP
2
CO
MP
1
AC
-L
AC
-N
AC
-N
AC
-N
KY
OU
T
MD
OU
T
NE
T
KY
IN
MD
IN
WA
TE
R
FR
OS
T
SY
S
ROOMT PIPE2 PIPE1 OUTWT INWT
VAL1
Compressor of system2 (220VAC) (no use)
COMP1
AC-L
AC-N
MDOUT GND Mode output (no use)
No. Symbol Meaning
4way valve of system1 (220VAC)
Compressor of system1 (220VAC)
NET GND 12V Wire controller
KYIN On/Off Switch (input) (no use)
Model (input) (no use)
WATER GND Flow switch (input) ( normal close)
FROST GND Defrost signa l(no use)
SYS GND 12V System protection (input) (normal close)
ROOMT Ambient temp. (input)
PIPE2 Temp of fan coil2 ( input) (no use)
12
13
14
15
16
17
18
19
20
21
22
MDIN
PIPE1
OUTWT Water out temp (input)
INTWT Water in temp. (input)
Temp of fan coil 1 (input) (no use for split type )
Neutral wire
SWIMMING POOL HEAT PUMP
37
Electric diagram:
SWIMMING POOL HEAT PUMP
38
HI
MC
FM
AC
-N
HI
LO
W
RED
GN
D
GN
D
GN
D
t`
EXT.
t`
Y/G
REDBLK
RS
C
BLU
COMP
BLU
L N
TO POWER SUPPLY
RED BLU
VA
L1
CO
MP
1
AC
-L
AC
-N
SY
S
KY
IN
MD
IN
WA
TE
R
ROOMTOUTWTINWT
RED
Y/G
L
BLU
N
RED
L
N
K1
BLU
N N
RK
1
BLU
RED
PU
MP
OUTIN
C1
DEFROSTING VALVE
RED
CMS
W1
t`
BLU
Y/G
BR
N
GN
D
12
V
NE
T
Wire Controller
HP
1L
P
RED RED
Chiller 300
SWIMMING POOL HEAT PUMP WIRING DIAGRAM
PIPE1
t`
PIPE2
Switch for stream
Switch forremote control
K2
SWIMMING POOL HEAT PUMP
Service
1. How to Obtain ServiceFor Pool Owner
If you are having a problem with the heater, FIRST perform the consumer troubleshooting steps
detailed in Owners Manual then CALL THE INSTALLING DEALER and have them verify that the
cause is NOT external (such as tripped breaker, clogged pool filter, inadequate pump run time, etc.)
Provide your Dealer with the following information:
1. Serial # located on back panel nameplate .
2. Proof of Installation Date .
3. Description of the Symptoms
For Installing Dealer
If your customer is having a problem with the unit and you as the installing dealer have verified that the
cause is NOT external (such as tripped breaker, clogged pool filter, inadequate pump run time, etc.)
following these steps will help you obtain the fastest service possible for your customer.
Help your customer gather the following information:
1. Serial # located on back panel nameplate .
2. Proof of Installation Date .
Will I Ever Need Freon
Unless your heat pump has a leak in the sealed refrigeration system, the factory charge of freon
should last for the life of the unit. Freon is very stable and should not degrade or breakdown even
under severe operating conditions. If your unit needs freon, then it has a leak, and adding freon will
not solve the problem. The leak must be located and repaired. A licensed HVAC contractor can handle
this repair.
39
SWIMMING POOL HEAT PUMP
SWIMMING POOL HEATING SYSTEM EVALUATION
Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun
Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun
1. The charts displayed for an outdoor poolEnergy flows in a heated pool
Energy flows in an unheated pool
Pool temperature
Range of pool temperature(max exceeded for 5% of the time and min. temperature exceed fo 95%of the time.
310
Attachment 1
SWIMMING POOL HEAT PUMP
311
Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr
2. The charts displayed for an indoor pool
Energy flows for indoor pool.
Pool temperature during daytime operating period.
temperature during daytime operating period.
humidity during daytime operating period.
Pool temperature at night.
temperature at night.
humidity at night.
Some of the charts are:
Air
Air
Air
Air
Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr
Outside
SWIMMING POOL HEAT PUMP
Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun
312
The position of installing unit
Side 600 mm Side 600 mm
Top 190 cm above
Inlet Inlet
Outlet
Heat
pump
Relative
Required clearances:
SWIMMING POOL HEAT PUMP
Attachment 2The Installation about Heat Pump & Chlorinator
313
In-line Chlorinator or Brominator
Check-valve
Filter
Chlorinator
Water Pump
Please start up the waterswitch (outside), if the insideone (in the machine) is notopen since the water flow isnot enough.
WATER FLOW SWITCH(inside)
TITANIUMEXCHANGER
WATER FLOW
WATER
PUMP
WATER FLOW SWITCH(outside)
A SERIES
HE
AT
GN
D
GN
D
12
V
GN
D
GN
D
GN
D
GN
D
12
V
Chiller 300
PU
MP
FA
N
VA
L2
VA
L1
CO
MP
2
CO
MP
1
AC
-L
AC
-N
AC
-N
AC
-N
KY
OU
T
MD
OU
T
NE
T
KY
IN
MD
IN
WA
TE
R
FR
OS
T
SY
S
ROOMT PIPE2 PIPE1 OUTWT INWT
Water flow switch installation
Pool/Spa
Heat Pump
Attachment 3
SWIMMING POOL HEAT PUMP
Common Units Conversion
Linear Measure
Square Measure
Cubic Measure
Capacity Measure
Avoirdupois Weight
Energy power
Velocity, flux
Pressure
1 inch =25.4 millimetres1 foot =12 inches =0.3048 metre1 yard =3 feet =0.9144 metre1 (statute) mile =1760 yards =1.609 kilometres1 nautical mile =1852 m.
1 square inch =6.45 sq.centimetres1 square foot =144 sq.in.=9.29 sq.decimetres1 square yard =9 sq.ft. =0.836 sq.metre1 acre =4840 sq.yd.=0.405 hectare1 square mile =640 acres =259 hectares
1 cubic inch =16.4 cu.centimetres1 cubic foot =1728 cu.in. =0.0283 cu.metre1 cubic yard =27 cu.ft. =0.765 cu.metre
1 pint 20 fluid oz. =34.68 cu.in. =0.568 litre1 quart =2 pints =1.136 litres1 gallon =4 quarts =4.546 litres1 peck =2 gallons =9.092 litres1 bushel =4 pecks=36.4 litres1 quarter =8 bushels =2.91 hectolitres
1 pint =33.60 cu.in. =0.550 litre1 quart =2 pints =1.101 litres1 peck =8 quarts =8.81 litres1 bushel =4 pecks =35.3 litres
1 pint =16 fluid oz. =28.88 cu.in. =0.473 litre1 quart =2 pints =0.946 litre1 gallon =4 quarts =3.785 litres
1 grain =0.065 gram1 dram =1.772 grams1 ounce =16 drams =28.35 grams1 pound =16 ounces =7000 grains =0.4536 kilogram1 stone =14 pounds =6.35 kilograms1 quarter =2 stones =12.70 kilograms1 hundredweight =4 quarters =50.80 kilograms1 short ton =2000 pounds =0.907 tonne1 (long) ton =20 hundredweight =1.016 tonnes
1 usrt =3024 kcal/h=3516 w1 kcal/h =1.163 w1 kw =860 kcal/h1 btu/h =0.293 w
1 m/s =196.85 fpm1 cfm = 1.699cmh1 gpm =0.27276 cmh1 gpm =0.2271 cmh
1 bar =100000 pa1 psi =0.0703 kgf/cm21 kgf/cm2 =98000 pa1 mm aq. =9.8 pa1 mm hg =133.28 pa1 m H2O =9800 pa =0.1 kgf/cm2
British
American dry
American liquid
314