0972 06/15
Triton SystemsTriton TT Admix Concrete SystemBS: 8102 (2009) Type B Integral Protection 1
Triton Contact Details:
Triton Systems Ltd. Units 3 5 Crayford Commercial Centre, Greyhound Way, Crayford, Kent DA1 4HF
Tel: 01322 318 830 Fax: 01322 524 017 Email: [email protected]
www.tritonsystems.co.uk
-
0972 06/15
CONTENTS:
1. Triton TT Admix Watertight Concrete System introduction and general guidelines
2. Batching sequence of procedures for addition of Triton TT Admix
3. Construction joint detailing
4. Service penetrations/tie bar detailing
5. Honeycomb and construction joint remedial measures
6. Types of cracks in concrete
7. TT Admix monitoring form
8. Specimen warranty
9. TT Admix Concrete System data sheets and MSDS: (Triton TT Admix, Triton Swellseal Mastic, Triton TT Waterstop, Installation guidelines for TT Waterstop/TT Swellseal Mastic, Triton Injection Tube, Triton Fillet Seal, Triton Quick Set)
10. Typical CAD Details
11. Case studies (Wembley, Brentford)
12. Triton Watertight Concrete Systems BBA Certificate
13. CE Marking Certificate (Declaration of Performance)
-
0972 06/15
Triton SystemsTriton TT Admix Watertight Concrete SystemIntroduction and general guidelines
1. IntroductionTriton has developed a watertight concrete system comprising an in depth-crystalline waterproofing admixture and hydrophilic waterstops and mastics for construction joints. This enables the construction of a watertight concrete structure in accordance with BS 8102 type B form of construction and waterproofing.
Along with quality products, Triton offers full system back up, including liaison with the concrete batching plant, mix design, construction joint detailing, site monitoring, repairs and warranty (where required).
For full information and support please read product data sheets attached and/or contact Tritons technical department on 01322 318830 or visit Tritons website www.tritonsystems.com.
2. TT AdmixA unique chemical treatment for the waterproofing and protection of concrete, which is added to concrete at time of batching. The active chemicals in the TT Admix react with fresh concrete to generate insoluble crystalline growths, that seal the concrete against water penetration and protect the concrete against harsh environmental conditions.
TT Admix will:
Withstand extreme hydrostatic pressure
Increase durability
Reduce shrinkage and cracking
Protect concrete and steel from aggressive chemicals such as chlorides
Seal static cracks to designed crack widths ( 0.3mm)
TT Admix is added to concrete at time of batching in dry powder form (see attached concrete batching details) at a rate of 1.17% by weight of cement.
-
0972 06/15
3. Concrete Mix RequirementsThe concrete mix requirements for optimum performance of the TT Admix requires a minimum cement content of 350kgs/m. The preference is for CEM1 (OPC), although a PFA* blend with a maximum 20% PFA content may be used. The maximum water cement ratio is 0.45.
To aid compaction we would recommend concrete be designed and supplied at an S3 consistence class (or higher).
For reference the use of GGBS (ground granulated blast furnace slag) is not permitted.
TT Admix: Alkali content 9.51% by weight of TT Admix.
Total Chlorine %
-
0972 06/15
6. Service Entry SealingAll service entry details and penetrations to the TT Admix concrete must be waterproofed using the TT Waterstop and/or TT Swellseal Mastic as indicated in drawing no.TT007.1 attached.
7. Placement & CuringNormal practices for the placement, compaction and curing of concrete should be followed as laid out in all relevant standards and in accordance with good concreting practice.
We would advise that concrete should not be poured or pumped from a height greater than 3.5m, to minimise the potential for aggregate segregation.
To aid compaction we would recommend concrete designed and supplied at S3 consistence class or higher.
Standard concrete practices to be adhered to with reference to ambient conditions at time of placement and appropriate curing regimes must be implemented, these should also be recorded on site monitoring records.
8. Optimum pour sizesWalls: Aspect ratios should not exceed 3:1 unless it has been agreed with the structural engineer.
Floor Slabs: The pour sizes should follow current guidelines in Construct National Specification. Typically this is 400m2.
9. Minimum wall and slab thicknessThis is the responsibility of the structural engineer, but we would generally advise a minimum 200mm to allow installation of the joint waterstops and allow adequate concrete cover.
10. MonitoringAll works should be subject to appropriate supervision by a representative of the client / contractor, who is responsible for maintaining records and photographs of the installation. Triton will monitor the whole process including concrete batching, placement, curing, construction joint detailing and repair. To facilitate this, the contractor to supply pour schedule and to advise Triton Systems of forthcoming pours with adequate notice - preferably 48 hours minimum.
In the event of the Triton Systems representative being unavailable, all records must be kept by the appointed representative of the contractor / client.
The following are minimum requirements for completion of records, failure to record adequate details may affect the provision of the warranty for the system:
Date Ambient conditions Pour location Pour size RMC delivery docket numbers Inspection/ confirmation and photographs of joint detailing Cracks, voids, honeycombing location Repair recommendations Repair completion dates
11. RepairsTriton Systems is solely responsible for product performance, the contractor is responsible for repairs in relation to poor workmanship such as voids, honeycombing etc. Defects owing to poor workmanship should be logged on site records along with confirmation of repairs being carried out.
Triton manufactures a range of compatible repair products and systems and any areas of honeycombing, voids or cracks should be repaired in accordance with TT Admix concrete repair details attached, and in accordance with the product data sheets for these products.
Alternate methods of repair such as resin injection can be used but please advise Triton Systems for verification prior to commencement.
-
0972 06/15
Triton Contact Details:
Triton Systems Ltd. Units 3 5 Crayford Commercial Centre, Greyhound Way, Crayford, Kent DA1 4HF
Tel: 01322 318 830 Fax: 01322 524 017 Email: [email protected]
www.tritonsystems.co.uk
12. NBS Specification Clauses TT Admix J10 120 Proprietary waterproof admixture
TT Waterstop E40 310 Designed joints in in situ concrete flexible waterstops
TT Swellseal Mastic E40 530 Designed joints in in situ concrete sealant
13. Standards and useful reference documentsBS 8102 (2009) Code of Practice for the protection of below ground structures against water from the ground
BS 8110 Structural use of concrete*
BS 8007 Design of concrete structures*
PCA Best practice Guidance : Type B waterproofing Systems
*EN 1992 (Eurocode 2) now refers
Waterproofing Design Guide General Guidance to BS 8102 (2009) The Concrete Centre
Concrete Basements Guidance on the design and construction of in-situ concrete basement structures The Concrete Centre
-
0972 06/15
Triton SystemsTriton TT Admix Watertight Concrete SystemBatching sequence of procedures for addition of Triton TT Admix
Triton TT Admix is added to the concrete at time of batching. The application rate is 1.2% BY WEIGHT OF CEMENT (1.2KG / 100KG OPC).
DRY BATCH PLANT:1. Add the weighed out TT Super Admix to the drum of ready mix truck.
2. Add 60 70% of gauging water to truck, along with 140 230kg of aggregate.
3. Mix materials for 2 3 minutes.
4. Add balance of materials to ready mix truck in accordance with standard batch procedures.
CENTRAL MIX OPERATION:1. Mix Triton TT Super Admix with water to form a slurry (6kg TT Super Admix with 10 litres water to form slurry).
2. Pour slurry into drum of ready mix truck.
3. Mix the aggregate, cement and water in the plant in accordance with standard batching procedures.
4. ENSURE WATER USED TO MAKE SLURRY IS TAKEN INTO ACCOUNT.
5. Add concrete to truck and mix for minimum of 5 minutes.
NB: FOR FURTHER INFORMATION AND HEALTH AND SAFETY INFORMATION, PLEASE REFER TO PRODUCT DATA SHEET AND HEALTH AND SAFETY DATA SHEET.
Triton Contact Details:
Triton Systems Ltd. Units 3 5 Crayford Commercial Centre, Greyhound Way, Crayford, Kent DA1 4HF
Tel: 01322 318 830 Fax: 01322 524 017 Email: [email protected]
www.tritonsystems.co.uk
-
0972 06/15
Triton SystemsTriton TT Admix Watertight Concrete SystemConstruction joint detailing
Kicker joint TT Swellseal Mastic being applied to pre-formed rebate at approximately 10mm bead
Kicker joint TT Waterstop and TT Swellseal Mastic applied to rebated joint
Triton Contact Details:
Triton Systems Ltd. Units 3 5 Crayford Commercial Centre, Greyhound Way, Crayford, Kent DA1 4HF
Tel: 01322 318 830 Fax: 01322 524 017 Email: [email protected]
www.tritonsystems.co.uk
-
0972 06/15
Triton SystemsTriton TT Admix Watertight Concrete SystemService penetrations/tie bar detailing
Service penetrations1. Refer to typical detail drawing
TT 007.1
2. Apply 10mm bead of TT Swellseal Mastic around service penetration
3. Apply TT Waterstop to TT Swellseal Mastic
4. If required, tie detail with fixing wire
Tie Bars1. Apply 10mm bead TT Swellseal
Mastic around tie bar
2. Apply TT Waterstop to Swellseal Mastic application
3. Tie at top with fixing wire
Triton Contact Details:
Triton Systems Ltd. Units 3 5 Crayford Commercial Centre, Greyhound Way, Crayford, Kent DA1 4HF
Tel: 01322 318 830 Fax: 01322 524 017 Email: [email protected]
www.tritonsystems.co.uk
-
0972 06/15
Triton SystemsTriton TT Admix Watertight Concrete SystemHoneycomb and Construction Joint Remedial Measures
1. IntroductionFollowing the placement, curing and compaction of the Triton TT Super Admix watertight concrete, upon removal of the formwork and exposing of the placed concrete, a visual inspection is required. If honeycombing or leaks to the construction joints are identified then the following remedial measures should be carried out:
2. Areas of Honeycombed ConcreteAny loose, friable concrete should be removed from the area, taking it back to a sound concrete base.
A liberal single coat application of Triton TT Super in depth crystalline waterproofer to be applied to the area.
Whilst the TT Super application is still green, Triton Fillet Seal, mixed as per data sheet, should be applied to the whole area to re-profile the concrete. This may need to be built up in layers depending on the depth required.
Following application of the Triton Fillet Seal, apply two further coats of the Triton TT Super slurry, extending beyond the area of repair by a minimum of 150mm.
3. Construction Joint RepairsThe construction joint should be chased out to create a minimum depth and width of 50mm to joint.
Where liquid water is seeping through joint, this should be plugged using Triton Quick Set plugging compound (TQS) as per details on attached data sheet.
Once leak has been stopped, apply a liberal application to the joint area of Triton TT Super.
Re-profile chased joint using Triton Fillet Seal, application as per attached Fillet Seal data sheet.
Overcoat the repaired joint with two coats of Triton TT Super, extending a minimum of 150mm to either side of joint.
4. Shutter Tie HolesRoughen the cleared concrete surface of shutter tie hole by appropriate means.
Apply single coat of TT Super to roughened surface.
Re-profile to flush with Triton Repair Mortar or Fillet Seal.
Apply two coats TT Super to repair and minimum 150mm to concrete surround.
Triton Contact Details:
Triton Systems Ltd. Units 3 5 Crayford Commercial Centre, Greyhound Way, Crayford, Kent DA1 4HF
Tel: 01322 318 830 Fax: 01322 524 017 Email: [email protected]
www.tritonsystems.co.uk
-
0972 06/15
Triton SystemsTriton TT Admix Watertight Concrete SystemTypes of cracks in concrete
1. Thermal cracksThese are caused by temperate rise, particularly in mass concrete, created by the heat of hydration. As the interior concrete increases in temperature and expands, the surface may be cooling and contracting thus causing tensile stress that may result in thermal cracks at the surface.
2. Drying shrinkage cracksAs most concrete mixes contain more water than actually required for the hydration process, the remaining water evaporates causing the concrete to shrink. Restraint to shrinkage causes tensile stresses to develop in the hardened concrete. Restraint to drying shrinkage is the most common cause of cracking in concrete.
3. Plastic shrinkage cracksThese are caused when the evaporation of water from the surface of freshly placed concrete is faster than it is replaced by bleed water, thus causing the surface to shrink. Due to restraint from the underlying concrete, tensile stresses develop in the weak plastic surface concrete resulting in shallow cracks of varying widths and depths.
Triton Contact Details:
Triton Systems Ltd. Units 3 5 Crayford Commercial Centre, Greyhound Way, Crayford, Kent DA1 4HF
Tel: 01322 318 830 Fax: 01322 524 017 Email: [email protected]
www.tritonsystems.co.uk
-
Triton SystemsUnits 3 5 Crayford Commercial Centre, Greyhound Way, Crayford, Kent DA1 4HFTel: 01322 318830 Fax: 01322 524017 Email: [email protected]
www.tritonsystems.co.uk
SITE INSPECTION / MONITORING FORM
Project Name: .......................................................................................................................................................................
Project Address: ...................................................................................................................................................................
.............................................................................................. Project Ref No: ......................................................................
Client Name: ........................................................................... Contractor Name: ..................................................................
System Type: ........................................................................................................................................................................
Weather: ..............................................................................................................................................................................
Date: ....................................................................................................................................................................................
SITE LOCATION PRODUCTS COMMENTS
This form to be completed after each inspection by a Triton Systems consultant and/or contractor, upon completion of each agreed stage of waterproofing works.
Completed forms along with associated information must be submitted to Triton Systems upon completion of the project.
Signed on behalf of contractor/client ......................................................................................................................................
Print name .............................................................................. Date .....................................................................................
Signed on behalf of Triton Systems ........................................................................................................................................
Print Name ............................................................................. Date ......................................................................................
Date: ...............................................
Ref: .................................................
-
Warranty for Triton TT Super Admix System
To the Client:
1.1 TRITON SYSTEMS is the supplier of the Triton TT Super Admix System for waterproofing of structural concrete used to all
areas on site as recorded in admix pour record sheets at the project and this
Triton TT Super Admix System work is completed on
1.2 TRITON SYSTEMS does assume responsibility for the visible migration of water through properly compacted Triton TT Super
Admix System concrete, contained in the concrete structures described above, for a period of ten years from the date of
completion of the Triton TT Super Admix System concrete work, subject to the conditions as laid out herein.
1.3 This warranty is conditional upon the full compliance by the Main Contractor, his nominee, and other trades and supplies,
with the main specifications tendered on and specifications, terms and conditions as set out by TRITON SYSTEMS for the use
of Triton TT Super Admix System. It is specifically noted here that the responsibility for the cement content in Triton TT Super
Admix System concrete being no less than 350kg per cubic metre, always rests with the contractor.
Furthermore, any refusal to comply with requests made by TRITON SYSTEMS representatives on matters concerning the
Triton TT Super Admix System concrete works will render this warranty null and void.
2.1 This warranty covers construction joints upon approval by TRITON SYSTEMS and pipe projections, shoring struts, and tie
holes, where these are constructed according to TRITON SYSTEMS LTD recommended details. Responsibility does not include
the penetration of water through cracks caused by structural failure or other causes, not through construction or expansion
joints, nor at any point where the designed thickness of the concrete has been reduced. Nor shall this responsibility include
water entry through honeycombing and/or voids made as a result of poor compaction of the Triton TT Super Admix System
concrete, or leaking formwork, nor for concrete that has been disturbed or tampered with.
2.2 This warranty does not include or cover liability for damage of failure of the Triton TT Super Admix System waterproofing
caused by fire, explosion, vibration, structural movement, lightning, thunderbolt, earthquake, riot, civil commotion, strikes or
labour disturbances.
2.3 TRITON SYSTEMS liability for any non-performance of the Triton TT Super Admix System then the Triton TT Super Admix works
conform to paragraph 2.1 shall not in any event exceed the value of the Triton TT Super Admix System admixtures supplied
and paid for, and is strictly limited only to the direct cost of repairs to or rectification of Triton TT Super Admix System
concrete through which visible water is migrating. The Value in this warranty being the maximum value of the TT Super Admix
supplied to the project in Great Britain, value in pounds sterling.
2.4 TRITON SYSTEMS shall be notified in writing of any non-performance of the Triton TT Super Admix System and the area
of non-performance within 14 days after such non-performance shall have come to the knowledge of the Client or his
representative having supervision of the Triton TT Super Admix System concrete works.
2.5 Remedial work, if necessary, will be carried out by and at the expense of TRITON SYSTEMS in a manner as may be
directed by the Company or our nominee as soon as practicable after advise of any non-performance of the Triton TT Super
Admix System has been received.
2.6 The issue of warranty is subject to all invoices been paid in full as per TRITON SYSTEMS current Terms and Conditions of sale.
Director Date TRITON SYSTEMS
SPEC
IMEN
-
Product Data Sheet
0885 09/14
Triton TT Admix
DescriptionTriton TT Admix is a unique chemical treatment for the waterproofing and protection of concrete. This admix is specially designed as a concrete additive at the time of batching.
IntroductionPacked as a dry powder compound, Triton TT Admix consists of Portland cement, very fine treated silica sand and various active proprietary chemicals. The active chemicals react with the moisture in the fresh concrete and the by-products of cement hydration causing a catalytic reaction that generates a non-soluble crystalline formation of dendritic fibres throughout the pores and capillary tracts of the concrete. Thus the concrete itself becomes sealed against the penetration of water or liquid, protecting the concrete from the deterioration effect of harsh environmental conditions.
Characteristics1. Maximizes waterproofness of concrete
2. Will withstand extreme hydrostatic pressure.
3. Exceptional durability.
4. Reduces shrinkage and cracking.
5. Protection of concrete against certain aggressive chemicals including chloride attack to steel reinforcing.
6. Improves workability of concrete.
7. Allows passage of air and water vapour.
8. Cost effective.
Concrete Mix Requirements: (See additional information sheet) For purposes of warranties, minimum cement content 350kg/m
Water: Cement ratio 0.45 (max 0.5)
-
0885 09/14
Directions for useFor waterproofing concrete the recommended addition rate for Triton TT Admix is 1.2% by weight of cement. For enhanced chemical resistance please consult with Tritons Technical Services to determine the approximate addition rate. Triton TT Admix is added to the concrete at the time of batching. The sequence of procedures for addition will vary according to the type of batch plant operation and equipment.
1. Ready Mix Plant Dry Batch OperationAdd Triton TT Admix in powder form to the drum of the ready-mix truck. Drive the truck under the batch plant and add 60% 70% of the required water along with 140kg 230kg of aggregate. Mix the materials for 2-3 minutes to ensure the Triton TT Admix is distributed evenly throughout the mix water. Add the balance of materials to the ready-mix truck in accordance with standard batch practices.
2. Ready Mix Plant Central Mix OperationMix Triton TT Admix with water to form a very thin slurry (e.g. 6kg 8kg lb. of powder mixed with 10 litres of water). Pour the required amount of material into the drum of the ready-mix truck. The aggregate, cement and water should be batched and mixed in the plant in accordance with standard practices (taking into account the quantity of water that has already been placed in the ready-mix truck). Pour the concrete into the truck and mix for at least 5 minutes to ensure even distribution of the Triton TT Admix throughout the concrete.
3. Precast Batch Plant Pan MixerAdd Triton TT Admix to the rock and sand, then mix thoroughly for 2-3 minutes before adding the cement and water. The total concrete mass should be blended using standard practices.
NOTE: It is important to obtain a homogeneous mixture of Triton TT Admix with the concrete. Therefore, do not add dry Triton TT Admix powder directly to wet concrete as this may cause clumping and thorough dispersion will not occur.
For further information regarding the property use of Triton TT Admix for a specific project, consult with a Triton technical representative.
Specification Type B Integral Protection in Accordance with BS8102 (2009)
NBS: Clause J10 120 Cementitious Mortar Tanking / Damp Proofing
CuringNormal practices for placing and curing concrete should be followed as laid out in your local standards.
Technical ServicesTechnical assistance is available through Tritons technical department or its field based technical representatives.
Packaging Triton TT Admix is available in 20kg Drums or pre-dosed 4.1kg water-soluble bags.
Product must be stored dry at a minimum temperature of 7C.
Shelf life is one year when stored under proper conditions.
Health & Safety Triton TT Admix is alkaline.
Protect hands with rubber gloves.
Avoid contact with skin and eyes. Should this occur, flush with water.
If irritation persists, contact physician.
Triton Contact Details:
Triton Systems Ltd. Units 3 5 Crayford Commercial Centre, Greyhound Way, Crayford, Kent DA1 4HF
Tel: 01322 318 830 Fax: 01322 524 017 Email: [email protected]
www.tritonsystems.co.uk
-
According to 93/112EC
Material Safety Data Sheet
0885 09/14
1. PRODUCT NAME Triton TT Admix2. HAZARD IDENTIFICATION
Mixing with water or contact of powder with body fluids produces a strong alkaline solution. This may cause serious burns and ulceration both to skin and eyes.
3. COMPOSITION
HAZARDOUS INGREDIENT Ordinary Portland Cement
CAS No. 65997-15-1
EC No. Weight % SymbolsXi (Irritant)
Risk Phrases36/37/38
Also contains graded silica sands or crushed limestone aggregates together with small quantities of other additives.
4. FIRST AIDCONTACT WITH SKIN: Wash the affected area thoroughly with soap and water. If irritation
continues seek medical advice. Clothing contaminated with wet product should be removed and washed thoroughly before re-use.
CONTACT WITH EYES: Wash eyes immediately with plenty of clean water for at least 15 minutes and seek medical advice without delay.
INGESTION: If swallowing has occurred, do not induce vomiting. Give person plenty of water to drink. Seek medial attention.
INHALATION: Move affected person to fresh air. If nose or airways become inflamed seek medical attention.
5. FIRE-FIGHTING MEASURESCement based products are not flammable and will not facilitate combustion of other materials.
EXPOSURE HAZARDS: Do not release water contaminated with cement-based products into surface drains.
6. ACCIDENTAL RELEASE MEASURESPERSONAL PRECAUTIONS: Avoid contact with skin, eyes and clothing. Avoid breathing dust.
ENVIRONMENTAL PRECAUTIONS: Prevent contamination of surface water.
CLEAN-UP PROCEDURES: Recover spillage in dry state if possible. Minimise generation of airborne dust. The product can be slurred with water. Keep children away from clean-up operations. Dispose to a place authorised to accept builders water. Small quantities can be disposed of as normal household waste.
MSDS Ref: TR Publication Date: 01/02/2003 Revision Date: 15/09/2011
IRRITANT
-
0885 09/14
According to 93/112EC
7. HANDLING AND STORAGEHANDLING PRECAUTIONS: When handling bags of cement-based products most of which weigh 25kg,
due regard should be paid to Manual Handling Regulations 1992. Some bags may have a small amount of cement dust on their outer surface. Appropriate personal protection should be used whilst handling.
STORAGE INFORMATION: Bags should be stacked in a safe and stable manner. Store in dry conditions.
8. EXPOSURE CONTROLS / PERSONAL PROTECTIONTECHNICAL PROTECTIVE MEASURES: No special measures required.
EXPOSURE LIMITS: Occupational Exposure Standard (OES) Limits 8 hour TWA (According to EH40/95).
All Triton cement based products contain powders, which if handled carelessly can raise dust.
The personal exposure to such dusts (cement, silica sand, crushed limestone etc.) must be kept below 10mg/m 8 hour TWA total inhalable dust and 5mg/m respirable dust. Some of the cement based products contain microsilica form of silica. The personal exposure level to amorphous silica must be kept below 6mg/m 8 hour TWA total inhalable dust and 3mg/m respirable dust.
Some sands and other fillers may contain small quantities of respirable silica for which the personal exposure must be kept below 0.4mg/m 8 hour TWA.
If care is taken not to raise dust and the exposure levels for nuisance dusts are not exceeded, the levels for respirable silica should be very low.
Applying Occupational Exposure Standards EH40/95 Sections 40 and 4.1. Also see Dust: General Principles of Protection HSE Guidance Note EH44 Rev 1991.
Occupational Exposure Standards Limits 8 hour TWA, reference period from Guidance Note EH40/95, Table 2.
AMORPHOUS SILICA: Total inhalable dust: 6mg/m Respirable dust: 3mg/m
PORTLAND CEMENT: Total inhalable dust: 10mg/m Respirable dust: 5mg/m
Suitable respiratory protection should be worn to ensure that personal OES is not exceeded. If care is taken not to raise dust during handling, the use of respirators is not normally necessary.
Wear suitable gloves.
Suitable goggles or face protection should be worn wherever there is a risk of product powder or product/water mixture entering the eye.
Wear overalls and closed footwear.
9. PHYSICAL AND CHEMICAL PROPERTIESPHYSICAL STATE: Particulate
PARTICAL SIZE: 5 6000 pm
Ph: of wet cement 12 14
-
0885 09/14
According to 93/112EC
10. STABILITY / REACTIVITYSTABILITY: Stable under normal room temperature storage conditions.
Bags will set solid if continually soaked with water.
11. TOXICOLOGICAL INFORMATIONCONTACT WITH EYES: Cement constituent is severe eye irritant. Mild exposures can cause
soreness. Gross exposures or untreated mild exposures can lead to chemical burning and ulceration of the eye.
CONTACT WITH SKIN: The powder or product/water mixture may cause irritation, contact dermatitis or allergic dermatitis and/or burns.
INHALATION: Inhalation of the powder may cause inflammation of mucous membranes.
INGESTION: The swallowing of small amounts of product or product/water mixtures is unlikely to cause any significant reaction. Larger doses may result in irritation to the gastro intestinal tract.
12. ECOLOGICAL INFORMATIONAQUATIC TOXICITY RATING: LC50 aquatic toxicity rating has not been determined. The addition of any
cement based product to water may, however, cause the pH to rise and therefore may be toxic to aquatic life in some circumstances. No other specific information available.
13. DISPOSAL CONSIDERATIONSDISPOSAL OF PRODUCT: Dispose of empty bags or surplus product to a place authorised to accept
builders waste. Keep out of reach of children. Small numbers of bags can be disposed of as normal household wastes.
14. TRANSPORT INFORMATIONClassification for transport not required.
15. REGULATORY INFORMATION
SYMBOLS: Xi Irritant
RISK PHRASES: R36/37/38: Irritating to eyes, respiratory systems and skin.
SAFETY PHRASES: S22: Do not breathe dust.
S28: After contact with skin, wash immediately with plenty of soap and water.
S26: In case of contact with eyes, rinse immediately with plenty of water and seek medical attention.
S24/25: Avoid contact with skin and eyes.
S37/39: Wear suitable gloves and eye/face protection. Keep out of reach of children.
READ ALL PRECAUTIONS BEFORE USEThe (COSHH) Control of Substances Hazardous to Health Regulations 1988 may apply to the use of this product at work. Engineering control of operator exposure must be used where reasonably practicable in addition to the following items of personal protective equipment.
WEAR SUITABLE PROTECTIVE CLOTHING, gloves and eye/face protection.
IN CASE OF CONTACT WITH EYES rinse immediately with plenty of water and seek medical advice.
AFTER CONTACT WITH SKIN, wash immediately with plenty of clean water.
KEEP OUT OF REACH OF CHILDREN.
Refer to other relevant legislation such as the Health and Safety at Work etc Act (HSWA), THE Control of Substances Hazardous to Health Regulations (COSHH), the Environment Protection Act and the Control of Pollution Act.
The information contained in this safety data sheet does not constitute the users own assessment of workplace risk as required by health and safety legislation.
-
0885 09/14
According to 93/112EC
Triton Contact Details:
Triton Systems Ltd. Units 3 5 Crayford Commercial Centre, Greyhound Way, Crayford, Kent DA1 4HF
Tel: 01322 318 830 Fax: 01322 524 017 Email: [email protected]
www.tritonsystems.co.uk
16. OTHER INFORMATION
The information contained in this data sheet is to the best of our knowledge accurate at the date of publication, but we cannot accept responsibility that it is sufficient or correct in all cases.
The data contained herein does not constitute a specification. Such information is available from the technical data sheet for the product.
Abbreviations:OES occupational exposure standard. STEL short-term exposure limit. LTEL long term exposure limit. TWA time weighted (8 hour) average. LEL lower explosive limit. UEL upper explosive limit.
-
Product Data Sheet
0885 09/14
Triton Swellseal Mastic
Field of ApplicationTriton Swellseal Mastic is used for:
Sealing rough and smooth construction joints of in-situ cast concrete.
Sealing joints between pre-cast segments (e.g. manholes, box culverts, cable ducts and pipes).
Sealing around steel H-beams.
Sealing between rough surfaces (e.g. slurry walls) and concrete slabs.
Bonding strip sealants to rough surfaces.
Sealing around bolt spacers and void formers.
On secant pile walls
Application Solvent free.
Triton Swellseal Mastic can be applied to concrete, PVC, HDPE, steel, etc.
The excellent filling and adhesion properties of the product provide a first line filling of cracks and voids, even on lightly humid, smooth or rough surfaces.
In contact with water Triton Swellseal Mastic will expand to about 350% of its original volume.
Flexible system, which adapts to the irregular surface of the substrate.
Easy application with standard caulking gun.
Durable: will exceed the constructions life.
Has a good all-round chemical resistance* and can resist to petroleum, mineral and vegetable oils and greases.
Triton Swellseal Mastic is approved for contact with potable water.
Description Triton Swellseal Mastic is a one-component, polyurethane based, solvent free, hydroswelling mastic, supplied in
cartridges and aluminium sausages, for the sealing of construction joints and around pipe penetrations.
Triton Swellseal Mastic cures and swells in the presence of moisture. Curing time depends on temperature and humidity conditions, i.e. curing time will reduce if RH and C are higher. Triton Swellseal Mastic will become firm in 24-36 hours. Performance is not affected by the curing time.
Application
1. Precautions Triton Swellseal Mastic is preferably applied onto a dust-free concrete surface.
The surface can be rough or smooth, moist or dry.
Installation during heavy rain or in prolonged contact with water results in a premature swelling of the strip, which should be avoided.
Preferably the mastic should cure for 24 hours before pouring concrete.
Despite the fact that Triton Swellseal Mastic has a very good adherence to the concrete, care must be taken, as with all products of this type, not to pour the concrete directly on the product to avoid damaging of the applied sealant.
-
0885 09/14
2. Application Method For 310cc cartridges
Break the moisture proofing aluminium foil on the top of the cartridge and remove the seamer from the bottom. Cut the nozzles diagonally at the appropriate position. Place the cartridge into caulking gun.
For 600cc sausages
Put the sausage in the empty tube of the caulking gun and cut 1 cm off the top of the sausage. Close the tube and install the nozzle. Cut the nozzle diagonally at the appropriate position.
Triton Swellseal Mastic is applied with a caulking gun in an uninterrupted band (minimum 10 mm wide and high), in the middle of the joint or prefab element. Concrete cover should be at least 7 cm on both sides, in order to avoid cracks from the expansion pressure of swelling Triton Swellseal Mastic.
Technical / Data Properties
Property Value Norm
Solids 100% Test DNC
Uncured
Consistency Gel / Paste Test DNC
Density (at 20C) Approx. 1.45 kg/dm3 DIN 53504
Slump in vertical applications < 5 mm (average 3 mm) Boeing test
Hand dry (at 20C and 60% rel. humidity)
12 h Test DNC
Flash Point > 130C Pensky-Martens method
Cured (7 days at 25C, 10 mm thick)
Elongation at break Approx. 625% DIN 53504
Tensile strength Approx. 2.2 N/mm2 DIN 53504
Resistance to hydrostatic pressure Up to 150 metres of water column Test DNC
Swelling capacity in contact with water
Swells to approx. 350% of its original dry volume
Test report KUL University
Appearance
During application pasty, after curing rubbery. Colour: White
ConsumptionThe consumption of Triton Swellseal Mastic per linear metre depends on the quality of the surface of the concrete.
Nozzle diameter Length (cartridge) Length (sausage)
3 mm 20 25 m 40 50 m
6 mm 8 10 m 16 20 m
8 mm 4 5 m 8 10 m
10 mm Approx. 3 m Approx. 6 m
Packaging
310 ml cartridges 600 ml sausages
12 per cardboard box 12 per cardboard box
1 pallet = 75 cardboard boxes 1 pallet = 40 cardboard boxes
Weight per cartridge0.55 kg gross0.50 kg net
Weight per sausage0.99 kg gross0.90 kg net
SpecificationNBS Clause E40 530 Designed Joints in-situ concrete.
-
0885 09/14
Triton Contact Details:
Triton Systems Ltd. Units 3 5 Crayford Commercial Centre, Greyhound Way, Crayford, Kent DA1 4HF
Tel: 01322 318 830 Fax: 01322 524 017 Email: [email protected]
www.tritonsystems.co.uk
StorageMinimum 12 months in a dry place at temperatures between 5C and 30C. See shelf life information on the packaging.
AccessoriesTo be ordered separately:
Skeleton caulking gun for cartridges 310 ml.
Caulking gun for sausages 600ml closed tube.
Nozzle for caulking gun 600mm closed tube.
Health & SafetyFor full information consult the relevant Material Safety Data Sheet.
* for chemical resistances please contact your Triton representative.
-
Product Data Sheet
0885 09/14
Triton Swellseal Mastic
Field of ApplicationTriton Swellseal Mastic is used for:
Sealing rough and smooth construction joints of in-situ cast concrete.
Sealing joints between pre-cast segments (e.g. manholes, box culverts, cable ducts and pipes).
Sealing around steel H-beams.
Sealing between rough surfaces (e.g. slurry walls) and concrete slabs.
Bonding strip sealants to rough surfaces.
Sealing around bolt spacers and void formers.
On secant pile walls
Application Solvent free.
Triton Swellseal Mastic can be applied to concrete, PVC, HDPE, steel, etc.
The excellent filling and adhesion properties of the product provide a first line filling of cracks and voids, even on lightly humid, smooth or rough surfaces.
In contact with water Triton Swellseal Mastic will expand to about 100% of its original volume.
Flexible system, which adapts to the irregular surface of the substrate.
Easy application with standard caulking gun.
Durable: will exceed the constructions life.
Has a good all-round chemical resistance* and can resist to petroleum, mineral and vegetable oils and greases.
Triton Swellseal Mastic is approved for contact with potable water.
Description Triton Swellseal Mastic is a one-component, polyurethane based, solvent free, hydroswelling mastic, supplied in
cartridges and aluminium sausages, for the sealing of construction joints and around pipe penetrations.
Triton Swellseal Mastic cures and swells in the presence of moisture. Curing time depends on temperature and humidity conditions, i.e. curing time will reduce if RH and C are higher. Triton Swellseal Mastic will become firm in 24-36 hours. Performance is not affected by the curing time.
Application
1. Precautions Triton Swellseal Mastic is preferably applied onto a dust-free concrete surface.
The surface can be rough or smooth, moist or dry.
Installation during heavy rain or in prolonged contact with water results in a premature swelling of the strip, which should be avoided.
Preferably the mastic should cure for 24 hours before pouring concrete.
Despite the fact that Triton Swellseal Mastic has a very good adherence to the concrete, care must be taken, as with all products of this type, not to pour the concrete directly on the product to avoid damaging of the applied sealant.
-
0885 09/14
2. Application Method For 310cc cartridges
Break the moisture proofing aluminium foil on the top of the cartridge and remove the seamer from the bottom. Cut the nozzles diagonally at the appropriate position. Place the cartridge into caulking gun.
For 600cc sausages
Put the sausage in the empty tube of the caulking gun and cut 1 cm off the top of the sausage. Close the tube and install the nozzle. Cut the nozzle diagonally at the appropriate position.
Triton Swellseal Mastic is applied with a caulking gun in an uninterrupted band (minimum 10 mm wide and high), in the middle of the joint or prefab element. Concrete cover should be at least 7 cm on both sides, in order to avoid cracks from the expansion pressure of swelling Triton Swellseal Mastic.
Technical / Data Properties
Property Value Norm
Solids 100% Test DNC
Uncured
Consistency Gel / Paste Test DNC
Density (at 20C) Approx. 1.45 kg/dm3 DIN 53504
Slump in vertical applications < 5 mm (average 3 mm) Boeing test
Hand dry (at 20C and 60% rel. humidity)
12 h Test DNC
Flash Point > 130C Pensky-Martens method
Cured (7 days at 25C, 10 mm thick)
Elongation at break Approx. 625% DIN 53504
Tensile strength Approx. 2.2 N/mm2 DIN 53504
Resistance to hydrostatic pressure Up to 150 metres of water column Test DNC
Swelling capacity in contact with water
Swells to approx. 100% of its original dry volume
Test report KUL University
Appearance
During application pasty, after curing rubbery. Colour: White
ConsumptionThe consumption of Triton Swellseal Mastic per linear metre depends on the quality of the surface of the concrete.
Nozzle diameter Length (cartridge) Length (sausage)
3 mm 20 25 m 40 50 m
6 mm 8 10 m 16 20 m
8 mm 4 5 m 8 10 m
10 mm Approx. 3 m Approx. 6 m
Packaging
310 ml cartridges 600 ml sausages
12 per cardboard box 12 per cardboard box
1 pallet = 75 cardboard boxes 1 pallet = 40 cardboard boxes
Weight per cartridge0.55 kg gross0.50 kg net
Weight per sausage0.99 kg gross0.90 kg net
SpecificationNBS Clause E40 530 Designed Joints in-situ concrete.
-
0885 09/14
Triton Contact Details:
Triton Systems Ltd. Units 3 5 Crayford Commercial Centre, Greyhound Way, Crayford, Kent DA1 4HF
Tel: 01322 318 830 Fax: 01322 524 017 Email: [email protected]
www.tritonsystems.co.uk
StorageMinimum 12 months in a dry place at temperatures between 5C and 30C. See shelf life information on the packaging.
AccessoriesTo be ordered separately:
Skeleton caulking gun for cartridges 310 ml.
Caulking gun for sausages 600ml closed tube.
Nozzle for caulking gun 600mm closed tube.
Health & SafetyFor full information consult the relevant Material Safety Data Sheet.
* for chemical resistances please contact your Triton representative.
-
According to 93/112EC
Material Safety Data Sheet
0885 09/14
1. PRODUCT NAME Triton TT Swellseal Mastic2. HAZARD IDENTIFICATION
Harmful to swallow. Irritating to eyes, respiratory organs and skin.
3. COMPOSITIONCONTENTS: Polyisocyanate (Prepolymers) of Diphenylmethanediisocyanate and
Methylphenylenediisocyanate, fillers and auxiliaries.
CAS No.: Does not apply (polymer, without Monomer)
EG No.: Does not apply (polymer, without Monomer)
4. FIRST AIDGENERAL DIRECTIONS: Immediately change product-stained clothes.
CONTACT WITH SKIN: Remove mechanically, wash immediately with soap and water and rinse will.
CONTACT WITH EYES: Wash with eye-lid open, rinse with running water. Seek medical attention.
INGESTION: Drink plenty of water. Go in the fresh air. Seek medial attention. By no means induce vomiting.
INHALATION: Seek medical attention.
5. FIRE-FIGHTING MEASURESSUITABLE EXTINGUISHER MEDIA: Carbon dioxide, powder or water jet. In a larger fire, use water spray or foam.
SPECIAL PROTECTIVE EQUIPMENT: Use breathing apparatus with independent air supply essential.
6. ACCIDENTAL RELEASE MEASURESPERSONAL PRECAUTIONS: Do not allow in drainage or groundwater.
ENVIRONMENTAL PROCEDURE FOR CLEANING AND REMOVAL:
Remove with liquid-absorbing materials (Kieselgurh, sawdust, oil binder). Place in disposal bins. Do not close Carbon Dioxide development Danger of bursting. Leave in a safe place for a number of days. The product reacts with water and sets.
7. HANDLING AND STORAGEHANDLING PRECAUTIONS: Keep containers dry and closed tightly. Avoid heating over 60C and cooling
under 10C. Ensure adequate ventilation or extraction of the work place. protect from heat. In the event of fire, cool the containers with water.
STORAGE INFORMATION: Store in a cool place. Maximum storage temperature 60C. Do not store with oxidising materials.
FURTHER INFORMATION: Do not store more than 6 months.
MSDS Ref: TR Publication Date: 22/06/2007 Revision Date: 15/09/2011
IRRITANT
-
0885 09/14
According to 93/112EC
8. EXPOSURE CONTROLS / PERSONAL PROTECTIONCOMPONENTS WITH WORKPLACE EXPOSURE LIMITS:
CAS No. Description of material: %: Form: Value: Standard: Additional Information:
Diisocyanate polymers on MDI and TDI basis. Approx. 22 Does not apply Does not apply Does not apply Basically the slits shown.
PERSONAL PROTECTION: In accordance with the specification of the Association for joint working.
Keep away from food, drinks and animal feeds. Immediately change clothes soiled by the product. Wash hands before meals and at the end of work.
Protective clothing should be worn, including eye protection and PVC or synthetic rubber gloves.
9. PHYSICAL AND CHEMICAL PROPERTIES
10. STABILITY / REACTIVITYSTABILITY: Does to apply.
CONDITIONS TO AVOID: No decomposition by correct handling and storage.
DANGEROUS REACTIONS: Not Known.
DANGEROUS DECOMPOSITION PRODUCTS:
Upon burning Carbon Monoxide, Nitric Oxide, Isocyanate vapour and traces of Hydrogen Cyanide.
11. TOXICOLOGICAL INFORMATIONACUTE TOXICITY: None by correct use. Over-exposure, especially inhalation of aerosol
vapours. Danger dependant on concentration. Irritation of the respiratory organs in over-sensitive people breathing difficulties, coughing, asthma.
PRIMARY IRRITATION EFFECT OF THE SKIN:
Can irritate the skin and mucous membrane.
PRIMARY IRRITATION EFFECT OF THE EYES:
Irritation.
SENSITIVITY: Possible with sensitive people on contact with skin.
12. ECOLOGICAL INFORMATIONWATER HARMFULNESS: Class 1 slightly harmful to water (own classification, WKG, Germany).
GENERAL INSTRUCTIONS: Do not discharge into ground water, drainage or rivers.
13. DISPOSAL CONSIDERATIONSDISPOSAL OF PRODUCT: Product reacts with water and sets to a physiologically harmless Polyurea
solid. The product can therefore be rendered inert by mixing with water and can be disposed of in sold form like domestic refuse.
DISPOSAL OF PACKAGING: Dispose according to local laws. Product can be rendered harmless by filling with water in open bins.
RECOMMENDED CLEANING MATERIAL: Remove mechanically with sand, sawdust or oil binder or spray with water.
Appearance Non flowing paste
Odour Typically faint
pH
Flash Point 180C
Explosive Properties No danger of explosion
Colour Red, brown, blue or black
Vapour Pressure 0.001 hPa at 20C
Density Approx. 1.3 g/ml at 20C
Water Solubility Totally Miscible (product emulsifies)
Ignition Temperature 250C
-
0885 09/14
According to 93/112EC
14. TRANSPORT INFORMATIONADR/RID & GGVS/GGVE E-Class Numbers/letters Mail Delivery Express goods
None None None Not allowed (in Germany)
15. REGULATORY INFORMATION
SYMBOLS: Xn, mildly toxic, contains prepolymers from 4,4 Diphenylmethane (MDI) and Methylphenylene (TDI) Diisocyanate.
RISK PHRASES: R20: Harmful to health on inhalation.R36/37/38: Irritates eyes, respiratory organs and skin.R42: Sensitivity possible through inhalation.
SAFETY PHRASES: S26: In case of contact with eyes, wash well with water and seek medical advice.S28: In case of contact with skin, wash immediately with soap and water.S28: Without adequate ventilation, wear breathing apparatus.S45: In the event of an accident or feeling unwell, seek medical advice. If possible, present this safety data sheet/label.
READ ALL PRECAUTIONS BEFORE USEThe (COSHH) Control of Substances Hazardous to Health Regulations 1988 may apply to the use of this product at work. Engineering control of operator exposure must be used where reasonably practicable in addition to the following items of personal protective equipment.
WEAR SUITABLE PROTECTIVE CLOTHING, gloves and eye/face protection.
IN CASE OF CONTACT WITH EYES rinse immediately with plenty of water and seek medical advice.
AFTER CONTACT WITH SKIN, wash immediately with plenty of clean water.
KEEP OUT OF REACH OF CHILDREN.
Refer to other relevant legislation such as the Health and Safety at Work etc Act (HSWA), THE Control of Substances Hazardous to Health Regulations (COSHH), the Environment Protection Act and the Control of Pollution Act.
The information contained in this safety data sheet does not constitute the users own assessment of workplace risk as required by health and safety legislation.
16. OTHER INFORMATION
The information contained in this data sheet is to the best of our knowledge accurate at the date of publication, but we cannot accept responsibility that it is sufficient or correct in all cases.
The data contained herein does not constitute a specification. Such information is available from the technical data sheet for the product.
Abbreviations:OES occupational exposure standard. STEL short-term exposure limit. LTEL long term exposure limit. TWA time weighted (8 hour) average. LEL lower explosive limit. UEL upper explosive limit.
Triton Contact Details:
Triton Systems Ltd. Units 3 5 Crayford Commercial Centre, Greyhound Way, Crayford, Kent DA1 4HF
Tel: 01322 318 830 Fax: 01322 524 017 Email: [email protected]
www.tritonsystems.co.uk
-
Product Data Sheet
0885 09/14
Triton TT Waterstop25mm x 20mm
IntroductionTriton TT Waterstop is a preformed waterstop consisting of sodium bentonite and butyl rubber and it swells up to 350% when in contact with water. When fully encapsulated by poured concrete, the expansive forces form a seal against concrete surfaces. This seal resists hydrostatic pressure, stopping water from entering the sub-structures. Triton TT Waterstop is able to withstand a 40 metre head of pressure. As with any hydrophilic waterstop, Triton TT Waterstop will return to its original size if the concrete and substrate is completely dry and no more moisture is present. If water or moisture is introduced again to the joints, Triton TT Waterstop will re-expand to seal the potential leaking joints.
Characteristics1. Service life is indefinite with excellent resistance to acid & alkaline condition.
2. East installation and extruded in rectangular shapes for optimal adhesion during application.
3. Permanent water-tight function.
Triton TT Waterstop has a built-in delay system thus the waterstop will activate approximately after 2 days of constant exposure to water.
Limitations Triton TT Waterstop should not be used for expansion joints or subject to repetitive movements.
Triton TT Waterstop should not be installed with less than 50mm of concrete cover to ensure that the pressure arising from the swelling action is accommodated.
-
0885 09/14
Specification
Physical Properties
Specific Gravity 1.35
Colour Black
Tensile Adhesion Strength > 30 kgf/cm
Volumetric Expansion Rate > 350%
Non-volatilization 99.7%
SpecificationNBS Clause E40 310 Designed joints in-situ concrete.
* For installation details see TT Waterstop / Swell Mastic installation guide.
Areas of application1. Poured in-situ construction joints.
2. Box culverts & retaining walls
3. Cut and cover tunnel construction
4. Underground (Utility) Vault Seal.
5. New to old concrete.
Volumetric Expansion
2 days 110%
3 days 250%
5 days 350%
2 days 105%
3 days 200%
5 days 350%
Packaging20mm x 25mm x 5m rolls 6 rolls per box
Box = 6 x 5m rolls (30m)
StorageTriton TT Waterstop has a self life of 24 months; stored in original unopened cartons in cool, dry conditions, away from direct sunlight.
Health & SafetyAlways read the Health and Safety data sheets before use.
Avoid skin and eye contact.
Avoid inhalation of vapours.
Wear safety glasses, gloves and overalls.
Triton Contact Details:
Triton Systems Ltd. Units 3 5 Crayford Commercial Centre, Greyhound Way, Crayford, Kent DA1 4HF
Tel: 01322 318 830 Fax: 01322 524 017 Email: [email protected]
www.tritonsystems.co.uk
-
According to 93/112EC
Material Safety Data Sheet
0885 09/14
1. PRODUCT NAME Triton TT Waterstop2. HAZARD IDENTIFICATION Do not ingest.
No dangers known.
3. COMPOSITION
HAZARDOUS INGREDIENT Bentonite Isobutylene Isprene Polybutylene
CAS No. 1302-78-9 9010-85-9 9003-28-5
EC No. Weight %65% 20% 15%
Symbols Risk Phrases
4. FIRST AIDIn all cases of doubt or when symptoms persist, always seek medical attention.
5. FIRE-FIGHTING MEASURESSUITABLE EXTINGUISHING MEDIA: Water, foam, CO2, dry powder to extinguish.
UNSUITABLE EXTINGUISHING MEDIA: No limitation known.
EXPOSURE RISKS: Keep away from fire. Do not inhale the liberated gas.
SPECIAL PROTECTIVE EQUIPMENT: Suitable oxygen breathing equipment.
6. ACCIDENTAL RELEASE MEASURESPERSONAL PRECAUTIONS: No precaution required.
7. HANDLING AND STORAGEHANDLING PRECAUTIONS: No protective equipment required.
STORAGE INFORMATION: Storage temperature limits are 5C to 45C.
FIREPROOF MEASURES: No particular precaution required (See exposure risks)
8. EXPOSURE CONTROLS / PERSONAL PROTECTIONNo special protective equipment required.
9. PHYSICAL AND CHEMICAL PROPERTIES
MSDS Ref: TR Publication Date: 07/2007 Revision Date: 15/09/2011
Appearance Solid Strips
Odour Not applicable
Steam Pressure Not applicable
Boiling Point Not applicable
Melting Point Not applicable
Solubility in solvent Insoluble
Colour Black
Explosion Danger Not applicable
Ignition Temperature >250C
Density 1.45
Viscosity Not applicable
Solubility in water Not applicable
-
0885 09/14
According to 93/112EC
10. STABILITY / REACTIVITYSITUATIONS TO AVOID: No dangerous situation known.
MATERIALS TO AVOID: No dangerous situation known.
DANGEROUS DECOMPOSITION PRODUCTS: No dangerous situation known.
11. TOXICOLOGICAL INFORMATIONACUTE TOXICITY: No animal testing has been made. On the basis of the single components
values, the following value of LD50 > 200,000mg/kg is presumed.
PRIMARY IRRITANT EFFECT: A prolonged contact might cause light irritations.
SENSIBILITY EFFECTS: No sensibility effects known.
CHRONIC TOXICITY: No data available.
12. ECOLOGICAL INFORMATIONDEGRADABILITY: The product is hardly degradable.
WATER TOXICITY: Not tested.
ECOLOGICAL TOXICITY: Not tested.
13. DISPOSAL CONSIDERATIONSDISPOSAL OF PRODUCT: Return goods to the manufacturer in the original packaging or deliver
(following the area regulations) to an authorised waste material collector.
WASTE MATERIAL CODE: Solid product, Hydrophilic Rubber products.
DISPOSAL OF PACKAGING: Discharge following the area regulations.
14. TRANSPORT INFORMATIONROAD TRANSPORT GGVE/GGVS: Not a dangerous goods in terms of national and international transport
regulations.
MARITIME TRANSPORT IMDG: Not a dangerous goods in terms of national and international transport regulations.
AIR TRANSPORT ICAO/IATA: Not a dangerous goods in terms of national and international transport regulations.
15. REGULATORY INFORMATION
READ ALL PRECAUTIONS BEFORE USEThe (COSHH) Control of Substances Hazardous to Health Regulations 1988 may apply to the use of this product at work. Engineering control of operator exposure must be used where reasonably practicable in addition to the following items of personal protective equipment.
WEAR SUITABLE PROTECTIVE CLOTHING, gloves and eye/face protection.
IN CASE OF CONTACT WITH EYES rinse immediately with plenty of water and seek medical advice.
AFTER CONTACT WITH SKIN, wash immediately with plenty of clean water.
KEEP OUT OF REACH OF CHILDREN.
Refer to other relevant legislation such as the Health and Safety at Work etc Act (HSWA), THE Control of Substances Hazardous to Health Regulations (COSHH), the Environment Protection Act and the Control of Pollution Act.
The information contained in this safety data sheet does not constitute the users own assessment of workplace risk as required by health and safety legislation.
-
0885 09/14
According to 93/112EC
Triton Contact Details:
Triton Systems Ltd. Units 3 5 Crayford Commercial Centre, Greyhound Way, Crayford, Kent DA1 4HF
Tel: 01322 318 830 Fax: 01322 524 017 Email: [email protected]
www.tritonsystems.co.uk
16. OTHER INFORMATION
The information contained in this data sheet is to the best of our knowledge accurate at the date of publication, but we cannot accept responsibility that it is sufficient or correct in all cases.
The data contained herein does not constitute a specification. Such information is available from the technical data sheet for the product.
Abbreviations:OES occupational exposure standard. STEL short-term exposure limit. LTEL long term exposure limit. TWA time weighted (8 hour) average. LEL lower explosive limit. UEL upper explosive limit.
-
Installation guidelines for TT Waterstop and TT Swellseal Mastic to construction joints
Min 15mm
Min 20mmMin 50mm Conc.Cover
1. Chase Cast in centre of wall section/joint section. Approximately 20mm x 15mm
4. Joint option for TT Waterstop (within chase)
Min 10mm BeadTT Swellseal Mastic to base of chase
2.
Min 10mm BeadTT Swellseal Mastic
TT Waterstop adhered to chase of Swellmastic
3.
Min 15mm
For further information and assistance please refer to www.triton-chemicals.com or call Tritons technical team on 020 8310 3929.
Typical vertical installation
Typical horizontal installation
0885 09/14
Triton Contact Details:
Triton Systems Ltd. Units 3 5 Crayford Commercial Centre, Greyhound Way, Crayford, Kent DA1 4HF
Tel: 01322 318 830 Fax: 01322 524 017 Email: [email protected]
www.tritonsystems.co.uk
-
Triton Injection Tube
DescriptionTriton Injection Tube is designed for waterproofing construction joints in new and old structures. Triton Injection Tube has been designed specifically for the multiple injection of suitable grouts into construction joints and other areas that may require injection at a later date.
Triton Injection Tube is constructed from a specially formulated plastic with special slots, which prevent the infiltration of concrete water and laitance during casting but open when internal pressure is applied. Its flexible nature allows it to follow contours and should be placed in lengths of 10 metres (up to 30 metres if required).
Key Benefitsn Simple Installationn Can be injected with all known resinsn Repeated injection possiblen Can withstand up to 12 metres head of pressuren Can be installed up to 30 metre lengths
Typical Applicationsn Concrete construction jointsn Shotcrete interfacesn Basement waterproofingn Water tanksn Bund wallsn Pipe penetrations
Application GuidelinesTriton Injection Tube can be placed between the reinforcement bars or along the interface joints of concrete slabs. It is held in place using specially designed clips to ensure it remains in place even during concrete pouring.
The concrete base to which the tubing is fixed should be smooth and flat to ensure that the tube lays flat without any kinks that would interfere with the performance of the tube.
The tubing is then placed on the flat surface and fixed onto the concrete with clips at approximately 200 to 300mm centres throughout the required length. At either end of the hose, there are 200mm-500mm lengths of hose, these are colour coded blue and clear, this helps to identify where one length starts and the other end finishes. There are two alternative ways of forming the injection points. The standard way is for these lengths to be placed through the formwork to provide easy access when the injection work is required.
Cast in place
During Injection
After cleaning out Injection
-
The alternative is to use the shutter connector system.
Note: It is important that the Triton Injection Tube is placed flat to ensure correct installation, and must not be placed against reinforcement, does not cross ridges including other lengths of hose or itself and must not bridge gaps.
When placing the tube, ensure that it is placed consistently using the colour coding. This will make it easier when injecting the resin especially when the injection will be carried out at a much later date. When injecting, follow the flow of the resin to ensure thorough penetration is achieved.
Technical Data Triton Injection Tube
Colour Orange
Size Internal 5-6mm
External 12mm
Construction Virgin PVC
Slot length 4mm
Toxicity Non-Toxic
Resin RequirementEach metre of Triton Injection Tube requires approximately 200ml of grout for each injection, we recommend the use of Tampur 170 injection resin or similar. For more detailed advice please contact Triton.
PackagingTriton Injection Tube is supplied in 10 metre packs and 100 metre packs complete with fixings and a choice of hose ends. Bulk is available on request.
Health & SafetyTriton Injection Tube should only be used as directed. We always recommend that the Health & Safety Data Sheet is carefully read prior to application of the material. Our recommendations for protective equipment should be strictly adhered to for your personal protection.
StorageTriton Injection Tube should be stored at room temperature (min 10C and max 35C), kept dry and out of direct sunlight.
Shutter Connector
Hose Connector
Hose Fixing Bracket
Inlet Hose
Outlet Hose
Injection Hose
Triton Contact Details:
Triton Systems Units 3 5 Crayford Commercial Centre, Greyhound Way, Crayford, Kent DA1 4HF
Tel: 01322 318830 Fax: 01322 524017 Email: [email protected]
www.tritonsystems.co.uk0624 11/11
-
Product Data Sheet
0885 09/14
Triton Fillet Seal
Description and UseA pre-packed cement based and polymer modified product for use as a floor to wall junction seal during waterproofing works when using cementitious slurry coatings (Triton TT55) and renders. In most circumstances Triton Fillet Seal need only be mixed with water for use. Where extra adhesion or flexibility are required, Triton SBR latex and Triton Tanking Mix Elastifier (T.T.M.E) may be uses respectively.
NOTE: Where water is leaking or seeping the use of Triton Quick Set is advised.
The use of Triton Fillet Seal helps to ensure a smooth transition between horizontal and vertical surfaces which minimizes the risk of leaving gaps or holes unsealed during the water proofing works.
PreparationSituations where the Triton Fillet Seal will be employed should already have been prepared in accordance with the slurry coating or render specification. In the majority of instances the Triton Fillet Seal will be applied onto the slurry coated surface as illustrated in FIG.1 below.
FIG.1
The Triton Fillet Seal becomes fully encapsulated within the layers of slurry coatings.
Concrete Slab
4:1 render orrenovating plaster
3:1 renderTT 55
Screed
-
0885 09/14
Usage Triton Fillet Seal normally needs only mixing with clean water before use.
Add sufficient water to make a cohesive, stiff mortar.
Ideally the Triton Fillet Seal should be applied to partly cured (green) slurry coating (Triton TT55) surfaces to maximize adhesion. If this is not possible make up the Triton Fillet Seal using a gauging solution composed of 1 part Triton SBR to 4 parts water (by volume).
Pre-wet the surface with the same solution just before applying the Triton Fillet Seal.
When excessive stress concentrations are expected at floor / wall joints the use of Triton T.T.M.E added to the mix is advised.
Triton T.T.M.E increases flexibility and should be added neat to Triton Fillet Seal until the required consistency is achieved.
The slurry coating (Triton TT55) under and overcoats should also contain Triton T.T.M.E.
NOTE: Only sound substrates suitable to be permanently sealed under a waterproofing system should be treated. Concrete, Brick, Stone, Render and Mortar in poor condition could deteriorate further when sealed inappropriately.
Application / Use Wall / Wall and Wall / Floor joint sealing in conjunction with Triton TT55 waterproofing system.
As a non shrink repair mortar for concrete and as part of repair system for Triton TT Super Admix System.
Curing Avoid rapid drying out, overcoat as soon as set (5-6 hours dependent on conditions) whenever possible.
Do not subject to running water until fully hardened (and overcoated).
Storage and Handling Avoid breathing dust.
Wear gloves and eye protection.
Wash hands and exposed skin after use.
Must be stored in dry frost-free conditions.
If bags are stored correctly and unopened they will have shelf life for 12 months.
Packed in 25kg bags.
Minimum application temperature: 5C.
Maximum application temperature: 30C
Coverage 15 20Lm (25mm x 25mm triangular fillet) per 25kg approximately.
Health & SafetyFor full information consult the relevant Material Safety Data Sheet.
*For chemical resistances please contact your Triton representative.
Triton Contact Details:
Triton Systems Ltd. Units 3 5 Crayford Commercial Centre, Greyhound Way, Crayford, Kent DA1 4HF
Tel: 01322 318 830 Fax: 01322 524 017 Email: [email protected]
www.tritonsystems.co.uk
-
According to 93/112EC
Material Safety Data Sheet
0885 09/14
1. PRODUCT NAME Triton Fillet Seal2. HAZARD IDENTIFICATION
Irritating to the skin. Risk of serious damage to eyes. May cause sensitisation by skin contact.
3. COMPOSITION
HAZARDOUS INGREDIENT Ordinary Portland Cement
CAS No. 65997-15-1
EC No. Weight %25
SymbolsXi (Irritant)
Risk PhrasesSee section 15
Also contains silica flour, silica sand and other additives.
4. FIRST AIDCONTACT WITH SKIN: Wash off with plenty of soap and water. Remove contaminated clothing.
CONTACT WITH EYES: Wash out with water for at least 15 minutes and seek medical advice without delay.
INGESTION: Wash out mouth with water and give plenty of water to drink. DO NOT INDUCE VOMITING.
INHALATION: Remove to fresh air. If nose or airways become inflamed, seek medical advice.
OTHER INFORMATION: Until the mixture has set, may cause both irritant and allergic contact dermatitis.
5. FIRE-FIGHTING MEASURESSUITABLE EXTINGUISHING MEDIA: As appropriate to surrounding fire.
SPECIAL PROTECTIVE EQUIPMENT: No particular requirements.
6. ACCIDENTAL RELEASE MEASURESPERSONAL PRECAUTIONS: Wear suitable protective clothing appropriate to the amount involved which
may include eye/face protection, PVC or synthetic rubber gloves, protective footwear and overalls, particularly during mixing operations.
ENVIRONMENTAL PRECAUTIONS: Contain the spillage and keep children away from the area.
CLEAN-UP PROCEDURES: Recover the spilt material in a dry state if possible. Minimise generation of airborne dust.
7. HANDLING AND STORAGEHANDLING PRECAUTIONS: Observe good hygiene standards and minimise skin contact.
Wear suitable protective clothing according to item 8.
STORAGE INFORMATION: Keep containers tightly closed in a cool place.
MSDS Ref: TR 312 Publication Date: 30/09/2002 Revision Date: 06/09/2011
IRRITANT
-
0885 09/14
According to 93/112EC
8. EXPOSURE CONTROLS / PERSONAL PROTECTIONWhen handling or mixing the product, protective clothing should be worn, including eye protection and PVC or synthetic rubber gloves.
Wash hands and exposed skin before meals and after work.
Do not wear contaminated clothing.
EXPOSURE LIMITS: Occupational exposure standard (8h TWA): 10mg/m total inhalable dust, 5mg/m respirable dust
9. PHYSICAL AND CHEMICAL PROPERTIES
Appearance Grey Powder
Odour None
pH 11, when wet
Boiling Point Not Relevant
Melting Point Not Relevant
Flash Point None
Autoignition temperature Not Combustible
Explosive Properties None
Oxidising Properties None
Vapour Pressure Not relevant
Relative density Not relevant
Bulk density 1300 kg/m
Viscosity Not relevant
Solubility Very slightly soluble in water
Partition Coefficient Not relevant
Other data None
10. STABILITY / REACTIVITYSTABILITY: Stable under normal conditions of use.
CONDITIONS TO AVOID: Damp (degrades product).
MATERIALS TO AVOID: No particular requirements.
11. TOXICOLOGICAL INFORMATIONSevere eye irritant. Irritating to skin the powder or its mixture with water may cause irritant dermatitis or burns, and traces of hexavalent chromium in the product may cause allergic dermatitis. Ingestion of small amounts is unlikely to cause any significant reaction, but large doses may result in irritation to the gastro intestinal tract.
12. ECOLOGICAL INFORMATIONMOBILITY: Not mobile in soil.
DEGRADABILITY: Relatively inert.
ACCUMULATION: No potential for bioaccumlation or biomagnification.
ECOTOXICITY: Addition of cement-based products to water may cause the pH to rise, and they may therefore be toxic to aquatic life in some circumstances.
13. DISPOSAL CONSIDERATIONSDISPOSAL OF PRODUCT: Dispose of in accordance with local and national regulations (normally
landfill), or to any place authorised to accept builders waste.
DISPOSAL OF PACKAGING: Packaging should be treated as for the product, or may be incinerated.
14. TRANSPORT INFORMATIONUN NO.: None assigned
PROPER SHIPPING NAME: Portland cement mixture
ADR/RID: Not classified as hazardous
IMCO: Not classified as hazardous
ICAO/IATA: Not classified as hazardous
PACKING GROUP:
LABEL: No hazard labe
-
0885 09/14
According to 93/112EC
Triton Contact Details:
Triton Systems Ltd. Units 3 5 Crayford Commercial Centre, Greyhound Way, Crayford, Kent DA1 4HF
Tel: 01322 318 830 Fax: 01322 524 017 Email: [email protected]
www.tritonsystems.co.uk
15. REGULATORY INFORMATION
CLASSIFICATION: Irritant
LABEL INFORMATION: IRRITATING TO THE SKINRISK OF SERIOUS DAMAGE TO THE EYESMAY CAUSE SENSITISATION BY SKIN CONTACTDO NOT BREATHE DUSTAVOID CONTACT WITH THE SKIN
READ ALL PRECAUTIONS BEFORE USEThe (COSHH) Control of Substances Hazardous to Health Regulations 1988 may apply to the use of this product at work. Engineering control of operator exposure must be used where reasonably practicable in addition to the following items of personal protective equipment.
WEAR SUITABLE PROTECTIVE CLOTHING, gloves and eye/face protection.
IN CASE OF CONTACT WITH EYES rinse immediately with plenty of water and seek medical advice.
AFTER CONTACT WITH SKIN, wash immediately with plenty of clean water.
KEEP OUT OF REACH OF CHILDREN.
Refer to other relevant legislation such as the Health and Safety at Work etc Act (HSWA), THE Control of Substances Hazardous to Health Regulations (COSHH), the Environment Protection Act and the Control of Pollution Act.
The information contained in this safety data sheet does not constitute the users own assessment of workplace risk as required by health and safety legislation.
16. OTHER INFORMATION
The information contained in this data sheet is to the best of our knowledge accurate at the date of publication, but we cannot accept responsibility that it is sufficient or correct in all cases.
The data contained herein does not constitute a specification. Such information is available from the technical data sheet for the product.
Abbreviations:OES occupational exposure standard. STEL short-term exposure limit. LTEL long term exposure limit. TWA time weighted (8 hour) average. LEL lower explosive limit. UEL upper explosive limit.
-
Product Data Sheet
0885 09/14
Triton Quick Set (T.Q.S)
Description and UseTriton Quick Set (T.Q.S) plugging compound is a one part fast setting cementitious material developed to stem water flow. T.Q.S as with all plugging compounds plug leaks to allow application of waterproofing layers to cure, but can be used as an all purpose instant setting repair mortar with a wide range of application.
A SIMPLE AND EASY TO USE VERSATILE MATERIAL, JUST ADD WATER.
Instructions for Use Mix up to 0.5kg of T.Q.S at a time.
Mix quickly with clean water to a mortar consistency within 30 seconds and apply immediately by trowel or gloved hand and apply constant even pressure (when plugging water flow approx. 30-60 seconds) until set.
Mixing Ratio Mix 1 part water to 4 parts powder by volume or 1 part water to 5 parts powder by weight. (Dry powder weight
approximately 1220gms per litre).
The mixing ratio is not critical and has little effect on the setting time.
T.Q.S Plugging compound is non-toxic, contains no chloride and is free from synthetic resins or epoxides.
Warning: Use rubber gloves to protect from heat generated during the setting period.
Storage Store in dry conditions.
Stored correctly, shelf life is 12 months
Consumption1.9kg/m per mm thickness.
Health & SafetyT.Q.S contains ordinary Portland cement and is alkaline when mixed. It is odourless, contains no organic solvent and is not flammable. In the case of eye or skin contact wash immediately with water or saline solution. Obtain medical attention if irritation persists. If ingested do not induce vomiting, wash mouth out with water, drink water and seek medical attention. Handle in accordance with good industrial hygiene and safety practices. Wear impermeable plastic or rubber gloves and enclosed goggles for eye protection at all times when handling alkaline materials. All chemical materials should be treated with care and kept away from children and animals at all times.
For full information consult the relevant Material Safety Data Sheet.
*For chemical resistances please contact your Triton representative.
-
0885 09/14
Triton Contact Details:
Triton Systems Ltd. Units 3 5 Crayford Commercial Centre, Greyhound Way, Crayford, Kent DA1 4HF
Tel: 01322 318 830 Fax: 01322 524 017 Email: [email protected]
www.tritonsystems.co.uk
B)A)
Chisel out defective area to a depth of approximately 50mm.
Wash out the cutting thoroughly with clean water to remove loose matter and soak the concrete
Stem the flow of water by plugging the back of the cutting as illustrated with Triton Quick Set.
Remove any loose material and ensure that the concrete is thoroughly soaked and will not absorb any more water.
Remove any surface ponding and treat the cavity with a brush on coat of TT55 as illustrated.
When the coating of TT55 has dried to a tacky consistency fill the cavity with Triton Fillet Seal ensuring the same is compacted back to surface
When mortar has set, apply a coating TT55 to the surface of the repaired area as shown.
T.Q.S
TT55
D)
Plugging Severe Leaks with Triton Quick Set
-
According to 93/112EC
Material Safety Data Sheet
0885 09/14
1. PRODUCT NAME Triton Quick Set (T.Q.S)2. HAZARD IDENTIFICATION
Irritating to the skin. Risk of serious damage to eyes. May cause sensitisation by skin contact.
3. COMPOSITION
HAZARDOUS INGREDIENT Rapid Portland Cement Calcium Aluminate Cement
CAS No. EC No. Weight %
-
0885 09/14
According to 93/112EC
8. EXPOSURE CONTROLS / PERSONAL PROTECTIONWhen handling or mixing the product, protective clothing should be worn, including eye protection and PVC or synthetic rubber gloves.
Wash hands and exposed skin before meals and after work.
Do not wear contaminated clothing.
EXPOSURE LIMITS: Occupational exposure standard (8h TWA): 10mg/m total inhalable dust, 5mg/m respirable dust
9. PHYSICAL AND CHEMICAL PROPERTIES
Appearance Grey Powder
Odour None
pH 11, when wet
Boiling Point Not Relevant
Melting Point Not Relevant
Flash Point None
Autoignition temperature Not Combustible
Explosive Properties None
Oxidising Properties None
Vapour Pressure Not relevant
Relative density Not relevant
Bulk density 1300 kg/m
Viscosity Not relevant
Solubility Very slightly soluble in water
Partition Coefficient Not relevant
Other data None
10. STABILITY / REACTIVITYREACTIVITY: Sets rapidly when mixed with water, large amounts will also heat up after mixing.
STABILITY: Stable under normal conditions of use.
CONDITIONS TO AVOID: Damp (degrades product).
MATERIALS TO AVOID: No particular requirements
11. TOXICOLOGICAL INFORMATIONSevere eye irritant. Irritating to skin the powder or its mixture with water may cause irritant dermatitis or burns, and traces of hexavalent chromium in the product may cause allergic dermatitis. Ingestion of small amounts is unlikely to cause any significant reaction, but large doses may result in irritation to the gastro intestinal tract.
12. ECOLOGICAL INFORMATIONMOBILITY: Not mobile in soil.
DEGRADABILITY: Relatively inert.
ACCUMULATION: No potential for bioaccumlation or biomagnification.
ECOTOXICITY: Addition of cement-based products to water may cause the pH to rise, and they may therefore be toxic to aquatic life in some circumstances.
13. DISPOSAL CONSIDERATIONSDISPOSAL OF PRODUCT: Dispose of in accordance with local and national regulations (normally
landfill), or to any place authorised to accept builders waste.
DISPOSAL OF PACKAGING: Packaging should be treated as for the product, or may be incinerated.
-
0885 09/14
According to 93/112EC
Triton Contact Details:
Triton Systems Ltd. Units 3 5 Crayford Commercial Centre, Greyhound Way, Crayford, Kent DA1 4HF
Tel: 01322 318 830 Fax: 01322 524 017 Email: [email protected]
www.tritonsystems.co.uk
14. TRANSPORT INFORMATIONUN NO.: None assigned
PROPER SHIPPING NAME: Portland cement mixture
ADR/RID: Not classified as hazardous
IMCO: Not classified as hazardous
ICAO/IATA: Not classified as hazardous
PACKING GROUP:
LABEL: No hazard labe
15. REGULATORY INFORMATION
CLASSIFICATION: Irritant
LABEL INFORMATION: IRRITATING TO THE SKINRISK OF SERIOUS DAMAGE TO THE EYESMAY CAUSE SENSITISATION BY SKIN CONTACTDO NOT BREATHE DUSTAVOID CONTACT WITH THE SKIN
READ ALL PRECAUTIONS BEFORE USEThe (COSHH) Control of Substances Hazardous to Health Regulations 1988 may apply to the use of this product at work. Engineering control of operator exposure must be used where reasonably practicable in addition to the following items of personal protective equipment.
WEAR SUITABLE PROTECTIVE CLOTHING, gloves and eye/face protection.
IN CASE OF CONTACT WITH EYES rinse immediately with plenty of water and seek medical advice.
AFTER CONTACT WITH SKIN, wash immediately with plenty of clean water.
KEEP OUT OF REACH OF CHILDREN.
Refer to other relevant legislation such as the Health and Safety at Work etc Act (HSWA), THE Control of Substances Hazardous to Health Regulations (COSHH), the Environment Protection Act and the Control of Pollution Act.
The information contained in this safety data sheet does not constitute the users own assessment of workplace risk as required by health and safety legislation.
16. OTHER INFORMATION
The information contained in this data sheet is to the best of our knowledge accurate at the date of publication, but we cannot accept responsibility that it is sufficient or correct in all cases.
The data contained herein does not constitute a specification. Such information is available from the technical data sheet for the product.
Abbreviations:OES occupational exposure standard. STEL short-term exposure limit. LTEL long term exposure limit. TWA time weighted (8 hour) average. LEL lower explosive limit. UEL upper explosive limit.
-
RC RAFT
DRY LINING SYSTEM
TRITON AQUA CHANNEL(TO SUITABLE DISCHARGE POINT)
PLATON MULTI MEMBRANE
PLATON P20 MEMBRANE
PLATON DOUBLE DRAIN
APP. BYCHK. BYDATEMOD. BY
DRAWN
DATE
CHECKED
APPROVED
TITLE:
DRG. No. REV
2
Triton Waterproofing - Typical DetailCombined System
TT Super Admix 'watertight Concrete'Plus
Isola Platon Cavity Drain System
SCALE (A3) TT-IP040-1(2).pdf
TT/IP 040.1
Not To Scale
JDF, CBS
10th July 2009
SystemFiles:
Alterations
REV.
TT-IP040-1(2).dwg
NOTE
MINIMUM 75mm SCREED
PLATON CORNERSTRIP
TRITON TT WATERSTOP/SWELL MASTIC
TRITON TT SUPER ADMIX'WATERTIGHT CONCRETE' TRITON TT WATERSTOP/SWELL MASTIC
RC
WA
LL
PIL
E
PILE CAP
2 Coats TRITON TTVAPOUR MEMBRANE
TRITON TTSUPER ADMIX RC
'INSPECTION PORT'
Units 3 - 5 Crayford Commercial Centre
Greyhound Way, Crayford, Kent. DA1 4HF
Email:
Web:
www.tritonsystems.co.uk
01322 318830
01322 524017
Telephone:
Fax:
Triton Systems
www.tritonsystems.co.uk
-
Units 3 - 5 Crayford Commercial Centre
Greyhound Way, Crayford, Kent. DA1 4HF
Email:
Web:
www.tritonsystems.co.uk
01322 318830
01322 524017
Telephone:
Fax:
Triton Systems
www.tritonsystems.co.uk
APP. BYCHK. BYDATEMOD. BY
DRAWN
DATE
CHECKED
APPROVED
TITLE:
DRG. No. REV
2
SCALE (A3) Not To Scale
JDF, CBS SystemFiles:
Alterations
REV.
NOTE
Concrete Construction JointsUsing
Triton TT Waterstop
TT 005.1
25-06-07
Wall To Floor Walls
FloorsNew & New To Old
Min
125mm
Min Concrete
Cover 50mm
Min Concrete
Cover 50mm
Triton TT Waterstop
Triton TT Waterstop
Min Concrete
Cover 50mm
Triton TT Waterstop
Please Note;
On rough concrete surfacesTriton TT Waterstop to be
adhered with Triton TT Swell Mastic
TT 005-1(2).pdfTT 005-1(2).dwg
-
Units 3 - 5 Crayford Commercial Centre
Greyhound Way, Crayford, Kent. DA1 4HF
Email:
Web:
www.tritonsystems.co.uk
01322 318830
01322 524017
Telephone:
Fax:
Triton Systems
www.tritonsystems.co.uk
APP. BYCHK. BYDATEMOD. BY
DRAWN
DATE
CHECKED
APPROVED
TITLE:
DRG. No. REV
2
SCALE (A3) Not To Scale
JDF, CBS SystemFiles:
Alterations
REV.
NOTE
Triton TT Swell Mastic
Reinforced Concrete
Service Entry Pipe
Service Entry Sealing ToConcrete Structures
TT 007.1
25-06-07
Triton TT Swell Mastic
Reinforced Concrete
Service Entry Pipe
Triton Fillet Seal
Triton TT Super(2 Coats)
New Construction Existing Structure
TT 007-1(2).pdfTT 007-1(2).dwg
-
Units 3 - 5 Crayford Commercial Centre
Greyhound Way, Crayford, Kent. DA1 4HF
Email:
Web:
www.tritonsystems.co.uk
01322 318830
01322 524017
Telephone:
Fax:
Triton Systems
www.tritonsystems.co.uk
APP. BYCHK. BYDATEMOD. BY
DRAWN
DATE
CHECKED
APPROVED
TITLE:
DRG. No. REV
1
SCALE (A3) TT-IP077-1(1).pdfTT-IP077-1(1).dwg
TT/IP 077.1
Not To Scale
JDF, CBS
20th August 2012
SystemFiles:
Alterations
REV.
NOTE
Type A External&
Type B Combined System
PLATON DOUBLE DRAINMEMBRANE
TRITON TT FILLET SEAL
LAND DRAIN TODISCHARGE POINT
2 - 3 Coats TRITON TTVAPOUR MEMBRANE
TRITON TT ADMIX CONCRETE
TRITON TT WATERSTOP/SWELLMASTICTO KICKER JOINT
TRITON TT ADMIX CONCRETE
PLATON P5 MEMBRANECONCRETE BLINDING LAYER
GEOTEXTILE
-
WATERTIGHT CONCRETE BASEMENT FOR LUXURY WEMBLEY DEVELOPMENT
Two 20 storey buildings, one a hotel and the other a luxury residential
and commercial apartment block, have been constructed a stones
throw from Londons Wembley Stadium. Triton was appointed by main
contractor, Donban Construction, to supply a watertight concrete
system (comprising type B method of waterproofing as defined in
BS 8102 2009) for the large underground car park which will serve
both buildings.
The watertight basement measures 80m x 70m x 4.5m deep and is
constructed from 2,000m3 of concrete incorporating Tritons Super
Admix to form the ring beam which can be seen in the photograph
sitting on top of contiguous piles the floor slab and the concrete
liner wall.
The ring beam waterproofed with Triton Super Admix
The development is a stones throw from Wembley Stadium
Case StudyTriton supplied: Triton Super Admix to produce 2,000m3 of watertight concrete, Triton TT Waterstop,Triton TT Swellseal Mastic
-
Dig out
T