    Trimec Industries is an Australian owned ISO9001:2008 quality certified company specializing in the design and manufacture of a proprietary range

    of positive displacement rotary piston, oval gear, insertion and impeller flow meters, ancillary flow hardware and dedicated electronic flow instrumentation. The meters measure the flow of clean liquids and are produced in a wide variety of materials and configurations to suit most

    markets including the food, chemical, cosmetic, ink, pharmaceutical, paint, petroleum and additive industries.

    The manufacturing facility is located close to Sydneys international airport. All design, assembly

    and calibration of the flow products is in house along with sales, administration and marketing supporting both domestic and international markets.

    The success of Trimec is attributed to the experience and knowledge acquired over a period of

    40 years by its key personnel in the flow measurement industry. Trimec is committed to developing and expanding its range of proprietary flow products to meet the ever changing

    needs of industry.

    Trimec also manufacture a complete range of complimentary flow instruments including remote or integral mounted flow rate totalizers and batch

    controllers, these instruments have both ATEX & IECEx hazardous area approvals.

    Trimec Industries business has been built initially around its Multipulse series positive

    displacement meters which were introduced in 1987, thus setting a new standard for quality and reliability at competitive pricing. The oval gear flowmeter range was

    added in order to extend the flow rate capacities of the product, offering for both low flow & high flow rate applications.

    The Oval gear meters are approved by the Australian National Measurement Institute

    (NMI) as an instrument for resale purposes (custody transfer). Most Trimec products have ATEX and IECEx approvals for explosion proof areas.

    C O M P A N Y P R O F I L E

  • P R O D U C T O V E R V I E W

    33www.trimecind.comwww.trimecind.comfor individual data sheets:

    MULTIPULSE PISTON FLOWMETERS

    The Oscillating Piston principal is widely established as the most simple & reliable of the positive displacement metering principals supporting industry to this day.

    MULTIPULSE OVAL GEAR FLOWMETERS

    These are Tr imec medium capaci ty flowmeters for pipe sizes from ~2 covering flows from 1~450 L/min.

    MAXIPULSE OVAL GEAR FLOWMETERS

    Trimecs 3 & 4 large capacity positive displacement flowmeters covering flows from 50 to 2500 litres/min.

    MICROPULSE OVAL GEAR FLOWMETERS

    Micropulse positive displacement meters measure small flow rates as low as L/hr of clean liquids both high & low viscosities.

    TURBOPULSE TURBINE FLOWMETERS

    Turbine flowmeters are highly accurate meters for measuring low viscosity liquids, sizes from to 20 cover flows from 3 litres/hr to 7000m3/hr.

    IMPELLER FLOWMETERS

    Tangential Impeller meters are low cost meters in the range of 1~70L/min for fuels, solvents, coolants & water.

    DUALPULSE INSERTION PADDLE WHEEL

    A cost effective means of measuring the flow of water & fuels in pipes from 1 to 100. Integral options provide great versatility for industries including HVAC & irrigation.

    FLOW INSTRUMENTATION

    Providing scaling, totalizing, batching, rate indication & programmable outputs, range includes mechanical totalisers.

    HIGH PRESSURE & SPECIFIC BUILD FLOW METERS

    These meters address the frequent technical issues typical of the off shore oil & gas, mining, exploration, hydraulic petroleum & marine industries.

    SPECIALTY FLOWMETERS

    S o l u t i o n s f o r i n d u s t r y s p e c i f i c applications. Additive injection, fuel oil burner blocks, fuel consumption & super acid proof meters.

    APPLICATIONS & LIQUID CHARACTERISTICSPage 21

    OVAL GEAR METER CHARACTERISTICSPage 23

    CALIBRATION, CERTIFICATES & APPROVALSPage 23

    Page 8-9

    Page 4-5

    Page 6-7

    Page 10-11

    Page 12-13

    Page 16

    Page 17

    Page 18

    Page 19

    CUSTODY TRANSFER FLOW METERS

    Flow meter ancillaries include strainers, air eliminators, back pressure check valves & Veeder Root style mechanicals.

    Page 14-15

    Page 20

  • 4

    P O S I T I V E D I S P L A C E M E N TP I S T O N F L O W M E T E R S

    MULTIPULSE MP Oscillating piston meters

    The MP series has long been established as a simple but reliable metering principal providing high levels of accuracy & repeatability for a wide range of liquids from extremely viscous lubricants, chemicals & food bases to non conductive solvents & fuels.

    Applications include alcohols, acetic acid, caustic soda, ethanol, fuels, grease, glucose, ink, insecticides, latex emulsions, liquid sugar, margarine, mayonnaise, molasses, resin, tallow, urethane, water, xylene & liquid yeast (refer page 21 for further applications).

    FEATURES : Insensitive to mounting orientation. Measure low & high viscosity liquids. Has only one moving part (oscillating piston). Certified Exd hazardous area versions in all sizes. No need for flow conditioning (straight pipe run etc.).

    STANDARD OPTIONS : Flanged and hygienic process connections, Explosionproof, integral and remote LCD totaliser-batch totaliser, flow rate totalisers, scaled pulse, 4~20mA & flow alarm outputs, electronic batch controllers and pulse processing modules.

    GENERAL SPECIFICATIONSGENERAL SPECIFICATIONSGENERAL SPECIFICATIONSModel prefix : MP010 MP015 MP020 MP025 MP040 MP050

    Nominal size mm ( " ) 10 (3/8") 15 (1/2") 20 (3/4") 25 (1") 40 (1.5") 50 (2")

    Flow range ( litres / min ) 0.2~10 0.2~10 2~50 2~50 4~140 12~330Flow range ( USG / min ) 0.05~2.7 0.05~2.7 0.5~13 0.5~13 1.1~37 3.2~90Accuracy @ 3cp * 1% o.r. 0.5% of reading

    Improved accuracy 0.2% of rate with optional NL correctionRepeatability typically 0.03%Temperature range -40C ~ +200C ( -40F ~ +390F )

    Maximum pressure ( threaded meters ) bar ( PSI )

    aluminium - 30 (440) - 80 (1200) 30 (440) 20 (300)316L stainless - 100 (1500) - 100 (1500) 100 (1500) 27 (380)

    high pressure stainless - 350 (5150) - 200 (2950) 250 (3700) -UPVC (SAP meters) 4 (60) - 4 (60) - - -

    Protection class IP66/67 (NEMA4X), optional Exd IIB T6 or I.S.Recommended filtering 150 microns ( 100 mesh ) minimumElectrical - for pulse meters ( see also optional outputs )Output pulse resolution pulses / litre ( pulses / US gallon )

    Reed switch 200 (760) 200 (760) 20 (76) 20 (76) 7.3 (28) 2.5 (9.5)Hall effect 400 (1520) 400 (1520) 100 (380) 100 (380) 44 (167) 20 (76)

    ** Reed switch output 30Vdc x 200mA max.Hall effect output (NPN) 3 wire open collector, 5~24Vdc, 20mA max.

    * Within nominal spans of MP015 ( 0.2~1.7, 1.7~5 & 5~10 litres/min )* Within nominal spans of MP015 ( 0.2~1.7, 1.7~5 & 5~10 litres/min )* Within nominal spans of MP015 ( 0.2~1.7, 1.7~5 & 5~10 litres/min )* Within nominal spans of MP015 ( 0.2~1.7, 1.7~5 & 5~10 litres/min )

  • 55www.trimecind.com 5www.trimecind.comfor individual data sheets:

    T E C H N I C A L I N F O R M A T I O NP I S T O N F L O W M E T E R S

    MODEL CODINGMP010P 3/8" ( 10mm ) UPVC onlyMP015 1/2" ( 15mm ) Alum. & stainlessMP020P 3/4" ( 20mm ) UPVC onlyMP025 1" ( 25mm ) Alum. & stainlessMP040 11/2" ( 40mm ) Alum. & stainlessMP050 2" ( 50mm ) Alum. & stainless

    Body materialBody materialBody materialBody materialBody materialA Aluminum S 316 Stainless SteelH High Pressure 316 stainlessP UPVC (5 bar max, 40C max)

    Piston material Piston material Piston material Piston material Piston material 2 PEEK - optional in all meters - 150C (300F) max.3 PTFE - standard in all meters - 120C max. ( 250F ) 9 Special materials - eg. for 200C ( 400F )

    Partition materialPartition materialPartition materialPartition materialPartition material1 Ceramic ( for abrasive liquids )2 316 Stainless Steel ( standard )

    O-ring materialO-ring materialO-ring materialO-ring materialO-ring material1 Viton ( standard ) -15~+200C (-5~+400F)2 Ethylene Propylene Rubber -150C (300F) max.3 Teflon encapsulated viton -150C (300F) max. 4 Buna-N (Nitrile) -65~+100C (-53~+212F)

    Temperature limits - 1 60C ( 140F ) - 2 120C ( 250F ) - see note 1 - 3 150C ( 300F ) - PEEK piston, NPN output - 4 40C ( 100F ) - UPVC meters - 5 120C ( 250F ) - see note 2 - 6 200C ( 400F ) - coil output

    Process connections Process connections Process connections Process connections Process connections 1 BSP ( RP ) female threaded 2 NPT female threaded

    * Triclamp ferrules are 1/2" 3 * Tri-clamp hygienic ferrules larger than the meter size 4 ANSI-150 RF flanges

    5 ANSI-300 RF flanges6 PN16 DIN flanges

    Cable entriesCable entriesCable entriesCable entrieswith B2 & B3 options only 0 3~6mm cable gland

    1 M20 x 1.5mm

    M o d e l N o. E x a m p l e 2 1/2" NPT

    MP015 S 2 2 1 - 2 1 2 R2

    Integral options Integral options Integral optionsglass reinforced nylon ( GRN ) GRN terminal cover (std.)

    SS Stainless terminal coverIECEx & ATEX approved E1 Explosion proof ~ Exd

    2 NPN open collector phase outputs QP Quadrature pulse output IECEx & ATEX approved Q1 Exd with Quadrature pulse

    accum. & reset totals, pulse output B2 BT11 dual totaliserIECEx & ATEX approved B3 Intrinsically safe BT11 (I.S.)

    flow rate, totals & all outputs R2 RT12 Flow Rate Totaliser IECEx & ATEX approved R3 Intrinsically safe RT12 (I.S.)large backlit LCD digits R4 RT20 Flow Rate Totaliser

    adapts to pulse output board FI Loop powered 4~20mA outputdc powered 2 stage batch controller E0 EB10 batch controller

    consult factory SB Specific build requirement

    All dimensions in millimeters +/- 2mmOption Fitted MP015 MP025 MP040 MP050

    1 143 179 201 2342 134 170 192 2253 147 183 205 2384 111 147 169 204

    C 75 98 140 168

    ConnectionsA C

    MP015 MP025 MP040 MP050 MP015 MP025 MP040 MP050ANSI 150 Flange 132 152 224 253 89 108 127 152ANSI 300 Flange 145 170 239 268 95 124 156 165DNI 16 Flange 140 165 235 258 95 115 150 165DNI 40 Flange 144 173 253 270 95 115 150 165BSP Screwed 100 117 175 202 - - - -NPT Screwed 100 117 175 202 - - - -

    (1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options. See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250 )(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250 )(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250 )(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250 )(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250 )(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250 )(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250 )(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250 )(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250 )(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250 )(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250 )(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250 )(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250 )(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250 )

    MP SERIES PRESSURE DROP CURVES @ 1cp VISCOSITY

    DIMENSIONS MODEL CODINGMP010PMP015MP020PMP025MP040MP050

  • 6

    S M A L L C A P A C I T Y O V A LG E A R F L O W M E T E R S

    MICROPULSE GEAR - Small capacity meters

    The Micropulse Oval series PD flowmeters offer a high level of accuracy turndown & repeatability. These precision meters are used for flow rate measurement in flow monitoring & control application and for totalizing in dispensing and batching.

    Micropulse gear meters are suitable for use with a wide range of clean liquids including viscous lubricants, chemicals, food bases & non-conductive low viscosity solvents either pumped or gravity fed.

    FEATURES : High accuracy & repeatability. Measure low & high viscosity liquids. Optional electronic registers. Certified Exd hazardous area versions in all sizes. No need for flow conditioning (straight pipe run etc.) Quadrature pulse output option & bi-directional flow. Specialty high pressure meters for mining & exploration.

    STANDARD OPTIONS : High resolution output, Explosionproof, integral and remote LCD totaliser-batch totaliser, flow rate totalisers, scaled pulse, 4~20mA & flow alarm outputs, electronic batch controllers and pulse processing modules.

    GENERAL SPECIFICATIONSGENERAL SPECIFICATIONSModel prefix : MG004 MG006 MG008

    Nominal size ( inches ) 4mm ( 1/8" ) 6mm ( 1/4" ) 8mm ( 3/8" )* Flow range - litres / hr 0.5 ~ 36 2 ~ 100 15 ~ 550 ( US gal./hr ) ( 0.13 ~ 9.5 ) ( 0.5 ~ 27 ) ( 4 ~ 145 )Accuracy @ 3cp 1% o.r. ( 0.2% with optional NL correction )Repeatability typically 0.03%Temperature range -20C ~ +120C ( -4F ~ +250F )

    Maximum pressure bar ( PSI )aluminium 15 ( 220 )

    316L stainless 34 ( 500 )high pressure stainless Refer Page 9

    Protection class IP66/67 (NEMA4X), optional Exd IIB T6 or I.S.Recommended filtering 75 micron ( 200 mesh ) minimumElectrical - for pulse meters (see also optional outputs)Output pulse resolution pulses / litre ( pulses / US gallon ) - nominal

    Reed switch 2800 ( 10600 ) 1050 ( 4000 ) 355 ( 1345 )Hall effect 2800 ( 10600 ) 1050 ( 4000 ) 710 ( 2690 )

    High Resolution Hall effect 11220 ( 42470 ) 4200 ( 15900 ) N/A** Reed switch output 30Vdc x 200mA max.Hall effect output (NPN) 3 wire open collector, 5~24Vdc, 20mA max.* Max. flow is to be reduced as viscosity increases, max. pressure drop 100Kpa. (15 psi)* Max. flow is to be reduced as viscosity increases, max. pressure drop 100Kpa. (15 psi)* Max. flow is to be reduced as viscosity increases, max. pressure drop 100Kpa. (15 psi)* Max. flow is to be reduced as viscosity increases, max. pressure drop 100Kpa. (15 psi)

  • 77www.trimecind.com 7www.trimecind.comfor individual data sheets:

    T E C H N I C A L I N F O R M A T I O NS M A L L C A P A C I T Y O V A L M E T E R S

    MODEL CODINGMG004 4mm ( 1/8" ) MG006 6mm ( 1/4" ) MG008 8mm ( 3/8" )

    Body materialBody materialBody materialBody materialA Aluminum S 316 Stainless SteelH High Pressure 316 stainless steel

    Rotor materialRotor materialRotor materialRotor materialRotor material5 316 stainless steel

    Bearing typeBearing typeBearing typeBearing type1 Ceramic

    O-ring materialO-ring materialO-ring materialO-ring materialO-ring material1 Viton ( standard ) -15~+200C (-5~+400F)2 Ethylene Propylene Rubber -150C (300F) max.3 Teflon encapsulated viton -150C (300F) max. 4 Buna-N (Nitrile) -65~+100C (-53~+212F)

    Temperature limitsTemperature limitsTemperature limitsTemperature limitsTemperature limits- 2 120C ( 250F ) - see note 1 - 5 120C ( 250F ) - see note 2

    Process connections Process connections Process connections Process connections Process connections 1 BSP female threaded 2 NPT female threaded

    Cable entriesCable entriesCable entries0 3~6mm cable gland1 M20 x 1.5mm2 1/2" NPT

    M o d e l N o. E x a m p l e

    MG006 S 5 1 1 - 5 1 2 R2

    Integral optionsIntegral optionsglass reinforced nylon ( GRN ) GRN terminal cover (std.)

    SS Stainless terminal coverIECEx & ATEX approved E1 Explosion proof ~ Exd

    2 NPN open collector phased outputs QP Quadrant pulse outputIECEx & ATEX approved Q1 Exd with Quadrature pulse

    MG004 = 11200ppL, MG006 = 4200ppL HR High resolution Hall Effect outputIECEx & ATEX approved H1 Exd with HR high resolution Hall

    for injected combustion engines PF Pulsating flow option (Hall effect only)IECEx & ATEX approved P1 Explosion proof ~ Exd with PF option

    with scaleable pulse output B2 BT11 dual totaliserIECEx & ATEX approved B3 Intrinsically safe BT11 (I.S.)

    flow rate, totaliser & all outputs R2 RT12 Flow Rate Totaliser IECEx & ATEX approved R3 Intrinsically safe RT12 (I.S.)large digit flow rate, totals R4 RT20 Flow Rate Totaliser

    adapts to pulse output board FI Loop powered 4~20mA outputdc powered 2 stage batch controller E0 EB10 batch controller

    consult factory SB Specific build requirement

    B B B AOPTIONS MG004 MG006 MG008 OPTIONS1 - RT EB 122 122 129 124

    2 - RT Alloy 125 125 132 963 - BT 113 113 120 94

    4 - Cover 94 94 99 72

    PRESSURE DROP & ERROR CURVES

    L : Light OilD : DieselP : Petrol

    Pres

    sure

    Dro

    p (k

    Pa)

    Erro

    r in

    %

    Flow Rate (Litres/hr)

    MG

    008

    MG

    004/

    006

    MG008MG006MG004

    DIMENSIONS

    (1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.

    See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB

    (2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250)(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250)(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250)(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250)(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250)(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250)(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250)(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250)(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250)(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250)(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250)(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250)(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250)(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250)

  • 8

    MULTIPULSE GEAR - Medium capacity meters

    The Multipulse Oval series PD flowmeters offer a high level of accuracy turndown & repeatability. These precision meters are used for flow rate measurement in flow monitoring & control applications and for totalizing in dispensing and batching.

    Multipulse gear meters are suitable for use with a wide range of clean liquids including additives, fuels, viscous lubricants, chemicals, food bases & non-conductive low viscosity solvents either pumped or gravity fed.

    FEATURES : High accuracy & repeatability. Measure low & high viscosity liquids. Optional mechanical & electronic registers. Certified Exd hazardous area versions in all sizes. No need for flow conditioning (straight pipe run etc.) Quadrature pulse output option & bi-directional flow. High pressure meters for mining & exploration.

    STANDARD OPTIONS : Flanged and hygienic process connections, Explosionproof, integral and remote LCD totaliser-batch totaliser, flow rate totalisers, scaled pulse, 4~20mA & flow alarm outputs, electronic batch controllers and a mechanical register.

    M E D I U M C A P A C I T Y O V A LG E A R F L O W M E T E R S

    GENERAL SPECIFICATIONSGENERAL SPECIFICATIONSModel prefix : MG015 MG025 MG040 MG050

    Nominal size ( inches ) 15mm ( 1/2" ) 25mm ( 1" ) 40mm ( 1.5" ) 50mm ( 2" )* Flow range (litres / min) 1 ~ 40 10 ~ 150 15 ~ 250 30 ~ 450* Flow range (USgal / min) 0.26 ~ 10.6 2.6 ~ 40 4 ~ 66 8 ~ 120Accuracy @ 3cp 0.5% of reading ( 0.2% with optional NL correction )Repeatability typically 0.03%Temperature range -20C ~ +120C ( -4F ~ +250F )Maximum pressure ( threaded meters ) Bar ( psig )

    aluminium 68 bar (1000) 68 bar (1000) 30 bar (440) 20 bar (300)316L stainless 68 bar (1000) 68 bar (1000) 30 bar (440) 38 bar (560)

    high pressure stainless 400 bar 400 bar 400 bar 300 barProtection class IP66/67 (NEMA4X), optional Exd IIB T6 or I.S.Recommended filtering 150 microns ( 100 mesh ) minimumElectrical - for pulse meters (see also optional outputs)Output pulse resolution : pulses / litre ( pulses / US gallon ) - nominal

    Reed switch 83 ( 314 ) 27 ( 102 ) 14 ( 53 ) 6.5 ( 25 )Hall effect 166 ( 628 ) 107 ( 405 ) 56 ( 212 ) 26 ( 99 )

    Quadrature Hall option 166 ( 628 ) 53.5 ( 203 ) 28 ( 106 ) 13 ( 50 )Reed switch output 30Vdc x 200mA max.Hall effect output (NPN) 3 wire open collector, 5~24Vdc, 20mA max.* Max. flow is to be reduced as viscosity increases, max. pressure drop 100Kpa. (15 psi)* Max. flow is to be reduced as viscosity increases, max. pressure drop 100Kpa. (15 psi)* Max. flow is to be reduced as viscosity increases, max. pressure drop 100Kpa. (15 psi)* Max. flow is to be reduced as viscosity increases, max. pressure drop 100Kpa. (15 psi)* Max. flow is to be reduced as viscosity increases, max. pressure drop 100Kpa. (15 psi)

  • 99www.trimecind.com 9www.trimecind.comfor individual data sheets:

    T E C H N I C A L I N F O R M A T I O NM E D I U M C A P A C I T Y O V A L M E T E R S

    All dimensions in millimeters

    Option FittedB B B B C C C C

    MG015 MG025 MG040H MG050 MG015 MG025 MP040H MP050RTI 2 / EB 145 164 196 208 124 124 160 180Mechanical 203 217 - 262 128 128 160 180

    RT 20 149 168 200 212 110 120 160 180BT 11 136 155 188 200 110 120 160 180Cover 113 132 165 177 110 120 160 180

    Modular Process A A A A C CConnections MP015 MP025 MP040 MP050 MP040 MP050

    ANSI 150 Flange - 213 - 300 108 152DIN 16 Flange - 213 - 300 115 165JIS 10K Flange - 213 - 300 125 165BSP Screwed 104 152 234 236 - -NPT Screwed 104 152 234 236 - -

    MODEL CODINGMODEL CODINGMODEL CODINGMODEL CODINGMODEL CODINGMODEL CODINGMODEL CODINGMG015 15mm ( 1/2" )MG025 40mm ( 1.5" )MG040 25mm ( 1" )MG050 50mm ( 2" )

    Body materialBody materialBody materialBody materialBody materialA Aluminum S 316 Stainless SteelH High pressure stainless

    Rotor material Rotor material Rotor material Rotor material Rotor material 4 Aluminum5 Stainless steel9 Application specific

    Bearing typeBearing typeBearing typeBearing typeBearing type1 Ceramic ( SS rotors )4 Hardened steel roller bearings ( Alum. rotors )

    O-ring materialO-ring materialO-ring materialO-ring materialO-ring material1 Viton ( standard ) -15~+200C (-5~+400F)2 Ethylene Propylene Rubber -150C (300F) max.3 Teflon encapsulated viton -150C (300F) max. 4 Buna-N (Nitrile) -65~+100C (-53~+212F)

    Temperature limitsTemperature limitsTemperature limitsTemperature limitsTemperature limits- 2 120C ( 250F ) - see note 1 - 5 120C ( 250F ) - see note 2

    Process connections Process connections Process connections Process connections Process connections 1 BSP female threaded 2 NPT female threaded 4 ANSI-150 RF flanges 5 ANSI-300 RF flanges6 PN16 DIN flanges9 Customer nominated

    Cable entriesCable entriesCable entries0 3~6mm cable gland1 M20 x 1.5mm2 1/2" NPT

    M o d e l N o. E x a m p l eMG025 A 4 4 1 - 5 1 1 R2

    Integral optionsIntegral optionsglass reinforced nylon ( GRN ) GRN terminal cover (std.)

    SS Stainless terminal coverIECEx & ATEX approved E1 Explosion proof ~ Exd

    2 NPN open collector phased outputs QP Quadrant pulseIECEx & ATEX approved Q1 Exd/Quadrant pulse

    for injected combustion engines PF Pulsating flow optionIECEx & ATEX approved P1 Explosion proof ~ Exd with PF optionwith scalable pulse output B2 BT11 dual totaliserIECEx & ATEX approved B3 Intrinsically safe BT11 (I.S.)

    flow rate, totaliser & all outputs R2 RT12 Flow Rate Totaliser IECEx & ATEX approved R3 Intrinsically safe RT12 (I.S.)Large backlite LCD digits R4 RT20 Flow Rate Totaliser

    adapts to pulse output board FI Loop powered 4~20mA outputdc powered 2 stage batch controller E0 EB10 batch controller

    consult factory SB Specific build requirement

    (1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options. See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250)(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250)(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250)(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250)(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250)(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250)(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250)(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250)(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250)(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250)(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250)(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250)(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250)(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250)

    DIMENSIONS

    ACCURACY CURVES & PRESSURE DROP

  • 10

    MAXIPULSE GEAR - Large capacity meters

    Trimec large capacity flowmeters are suited for receipt verification, loading, un-loading & distribution management at petroleum depots, mine sites, marine, aviation & industrial facilities.

    Common applications involve fuels, oils, solvents, alcohols along with the blending of Bio-fuels & ethanol fuels either pumped or gravity fed. The meters are compact & light weight in construction, important benefits when used in mobile installations or within confined spaces.

    FEATURES : High accuracy & repeatability. Measure low & high viscosity liquids. Optional mechanical & electronic registers. Certified Exd hazardous area versions in all sizes. No need for flow conditioning (straight pipe run etc.) Quadrature pulse output option & bi-directional flow. Optional integral check valves.

    STANDARD OPTIONS : Flanged process connections, Explosionproof, Mechanical registers, integral and remote LCD totaliser-batch totaliser, flow rate totalisers, scaled pulse, 4~20mA & flow alarm outputs, electronic batch controllers and pulse processing modules.

    GENERAL SPECIFICATIONSGENERAL SPECIFICATIONSModel prefix : MG080E MG100

    Nominal size ( inches ) 80mm ( 3" ) 100mm ( 4" )* Flow range ( litres / min ) 50 ~ 1000 75 ~ 1500* Flow range ( gal / min ) 13 ~ 260 20 ~ 400Accuracy @ 3cp 0.2% of reading (15:1 turndown) 0.5% for 20:1Repeatability typically 0.03%Temperature range -20C ~ +120C ( -4F ~ +250F )

    Maximum pressure ( threaded meters ) aluminium 12 bar (180 psig) 10 bar (150 psig)

    Ductile iron 12 bar (180 psig) 10 bar (150 psig)Protection class IP66/67 (NEMA4X), optional Exd IIB T6 or I.S.Recommended filtering 350 microns ( 40 mesh ) minimum

    Electrical - for pulse meters (see also optional outputs)Output pulse resolution pulses / litre ( pulses / US gallon ) - nominal

    Reed switch 1.55 ( 5.87 ) 1.1 ( 4.15 )Hall effect 6.2 ( 23.5 ) 4.4 ( 16.6 )

    Quadrature Hall option 3.1 ( 11.8 ) 2.2 ( 8.3 )** Reed switch output 30Vdc x 200mA max.Hall effect output 3 wire NPN open collector, 5~24Vdc, 20mA max.

    * Max. flow is to be reduced as viscosity increases, max. pressure drop 100Kpa. (15 psi)* Max. flow is to be reduced as viscosity increases, max. pressure drop 100Kpa. (15 psi)* Max. flow is to be reduced as viscosity increases, max. pressure drop 100Kpa. (15 psi)

    L A R G E C A P A C I T Y O V A LG E A R F L O W M E T E R S

  • 1111www.trimecind.com 11www.trimecind.comfor individual data sheets:

    T E C H N I C A L I N F O R M A T I O NL A R G E C A P A C I T Y O V A L M E T E R S

    MODEL CODINGMG080E 80mm MG100 100mm ( 4" )

    Body materialBody materialBody materialBody materialA Aluminum

    Rotor material Rotor material Rotor material Rotor material Rotor material 4 Aluminum

    Bearing typeBearing typeBearing typeBearing type4 Hardened steel needle roller bearings

    O-ring materialO-ring materialO-ring materialO-ring materialO-ring material1 Viton ( standard ) -15~+200C (-5~+400F)2 Ethylene Propylene Rubber -150C (300F) max.3 Teflon encapsulated viton -150C (300F) max. 4 Buna-N (Nitrile) -65~+100C (-53~+212F)

    Temperature limitsTemperature limitsTemperature limitsTemperature limitsTemperature limits- 2 120C ( 250F ) - see note 1 - 5 120C ( 250F ) - see note 2

    Process connections Process connections Process connections Process connections Process connections 1 BSP female threaded 2 NPT female threaded 4 ANSI-150 RF flanges 5 ANSI-300 RF flanges6 PN16 DIN flanges9 Customer nominated

    Cable entriesCable entriesCable entrieswith B2 & B3 options only 0 3~6mm cable gland

    1 M20 x 1.5mm2 1/2" NPT

    M o d e l N o. E x a m p l eMG100 A 4 4 1 - 5 4 2 R2

    Integral optionsIntegral optionsglass reinforced nylon ( GRN ) GRN terminal cover (std.)

    SS Stainless terminal coverIECEx & ATEX approved E1 Explosion proof ~ Exd

    2 NPN open collector phased outputs QP Quadrant pulse outputIECEx & ATEX approved Q1 Exd with Quadrature pulse

    for injected combustion engines PF Pulsating flow optionIECEx & ATEX approved P1 Explosion proof ~ Exd with PF option

    with scaleable pulse output B2 BT11 dual totaliserIECEx & ATEX approved B3 Intrinsically safe BT11 (I.S.)

    flow rate, totaliser & all outputs R2 RT12 Flow Rate Totaliser IECEx & ATEX approved R3 Intrinsically safe RT12 (I.S.)Large backlite LCD digits R4 RT20 Flow Rate Totaliser

    adapts to pulse output board FI Loop powered 4~20mA outputdc powered 2 stage batch controller E0 EB10 batch controller

    consult factory SB Specific build requirement

    All dimensions in millimetersModular Process A A C C Option B B

    Connections MG080H MG100 MG080H MG100 MG080H MG100ANSI 150 Flange 482 482 190 229 1 - RT EB 270 315

    DIN 16 Flange 482 482 200 220 2 - RT ALLOY 274 319JIS 10K Flange 482 482 185 210 3 - BT 11 262 307BSP Screwed 394 394 - - 4 - COVER 238 283NPT Screwed 394 394 - -

    DIMENSIONS

    ACCURACY CURVES & PRESSURE DROP

    (1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options.(1) 120C (250F) for pulse meters, 80C (180F) rating with BT, RT & EB options. See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB See temperature code 5 for higher temperature with BT, RT, & EB(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250 )(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250 )(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250 )(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250 )(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250 )(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250 )(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250 )(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250 )(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250 )(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250 )(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250 )(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250 )(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250 )(2) Cooling fin fitted to integral instruments for operation from 80~120C (180~250 )

  • 12

    TURBOPULSE small & large capacity meters

    TM Turbopulse mini & the larger TP Turbopulse turbine series measure flows of low viscosity liquids from 3 to 7,000,000 litres/hr in a range of sizes from to 20 (6mm~500mm).

    The TM mini series have a tangential rotor with integral flow conditioning ports whilst the TP series have an axial rotor and flow guides, the TP series needs to be installed in straight sections of pipe either horizontal or vertical so that the flow is conditioned. The TP series have Exd & Intrinsically Safe (I.S.) approvals.

    Both meter series are robust, compact & take little space in the piping system. Applications include fuels, alcohols, solvents, insecticides, milk, chemicals, water & light hydraulic oils.

    FEATURES : High accuracy & repeatability. Low cost of ownership, wide flow range. Rugged & compact design. Certified Exd & I.S. hazardous area versions. Quadrature pulse output option. Integral or remote pre-amplifiers & flow instruments. 0.15% custody transfer models available.

    STANDARD OPTIONS : Flanged process connections, Explosionproof, integral and remote preamplifier, LCD totaliser-batch totaliser, flow rate totalisers, scaled pulse, 4~20mA & flow alarm outputs, electronic batch controllers and pulse processing modules.

    GENERAL SPECIFICATIONSGENERAL SPECIFICATIONSModel prefix : TM-Turbopulse mini TP-Turbopulse

    Nominal sizes 6mm ( 1/4" BSPF ) 12~500mm (1/2"~20" )Accuracy @ 1cp 1~2% FSD or 0.75% o.r. 0.5% o.r. (10:1 turndown)Temperature range 5~125C (40~250F) -40~+240C (-40~+460F)Maximum pressure

    316 stainless steel 10 bar (147 psi) 250 bar (3680 psi) 10cst max.high pressure SS N/A 400 bar (5580 psi), 68cst max.

    Peek 10 bar ( 147 psi ) N/AProtection class IP66/67 (NEMA4X), optional Exd IIB T6 or I.S.Electrical (see also optional outputs - Turbopulse pick-off types)

    standard output Hall effect sensor Pick-off Coil

    FLOW RANGES - TP Turbopulsesize model litres/hr (GPH) TP010 100~1100 (0.44~4.4)" TP012 220~2200 (0.97~9.7)" TP015 400~4000 (1.77~17.7)" TP020 800~8000 (3.5~35.2)

    m3/hr (GPM)1" TP025 1.6~16 (7~70)

    1 TP040 3.4~34 (15~150)2" TP050 6.8~68 (30~300)3" TP080 13~135 (60~600)4" TP100 27~270 (120~1200)6" TP150 55~550 (240~2400)8 TP200 110~1100 (480~4800)

    10 TP250 190~1900 (840~8400) 12 TP300 270~2700 (1200~12000) 16 TP400 400~4000 (1800~18000) 20 TP500 700~7000 (3000~30000)

    FLOW RANGES - TM Turbopulse Minisize model litres/min (GPM) Jet " TM001 0.05~0.5 (0.01~0.13) 1mm" TM002 0.12~1.5 (0.03~0.4) 2mm" TM003 0.2~4.5 (0.04~1.12) 3mm" TM004 0.25~6.5 (0.05~1.7) 4mm" TM005 0.3~10 (0.08~2.64) no jet" TM006 0.5~15 (0.13~4) 6mm

    TM MiniTurbopulse

    TurbopulseRange

    T U R B I N E F L O W M E T E R S

  • 13www.trimecind.comfor individual data sheets:

    T E C H N I C A L I N F O R M A T I O NT U R B I N E F L O W M E T E R S

    TURBOPULSE MODEL CODINGTURBOPULSE MODEL CODINGTURBOPULSE MODEL CODINGTURBOPULSE MODEL CODINGTURBOPULSE MODEL CODINGTURBOPULSE MODEL CODINGTURBOPULSE MODEL CODINGTURBOPULSE MODEL CODINGTURBOPULSE MODEL CODINGTURBOPULSE MODEL CODINGTURBOPULSE MODEL CODINGTURBOPULSE MODEL CODING Pulse output (nominal) : P/litre P/USG frequency (Hz)

    TP010 1/2" ( DN15 ) 4000 15140 120~1200TP012 3/4" ( DN20 ) 1700 6435 104~1040TP015 3/4" ( DN20 ) 1100 4160 120~1200TP020 3/4" ( DN20 ) 400 1500 90~900TP025 1" ( DN25 ) 180 680 80~800TP040 1 1/2" ( DN40 ) 60 230 57~570TP050 2" ( DN50 ) 24 90 45~450TP080 3" ( DN80 ) 15 57 56~560TP100 4" ( DN100 ) 6.6 25 50~500TP150 6" ( DN150 ) 2.3 8.7 35~350TP200+ 8~20" ( DN200 to DN500 ) - consult factory for more details

    Body MaterialBody MaterialBody MaterialBody MaterialBody MaterialS 316 stainless steel - 250 bar (3500 psi) max.H high pressure SS, 400 bar (5580psi) - 68cst max.

    Process ConnectionsProcess ConnectionsProcess ConnectionsProcess ConnectionsProcess ConnectionsProcess ConnectionsProcess Connections1 BSPP male threaded2 NPT male threaded3 * Tri-clamp ferrules (316SS) 4 ANSI-150 RF flanges5 ANSI-300 RF flanges6 PN10 DIN flanges7 PN16 DIN flanges8 PN25 DIN flanges9 Customer nominated connections

    * triclamp ferrules are 1/2" larger than the meter size* triclamp ferrules are 1/2" larger than the meter size* triclamp ferrules are 1/2" larger than the meter size* triclamp ferrules are 1/2" larger than the meter size* triclamp ferrules are 1/2" larger than the meter size* triclamp ferrules are 1/2" larger than the meter size* triclamp ferrules are 1/2" larger than the meter size* triclamp ferrules are 1/2" larger than the meter size* triclamp ferrules are 1/2" larger than the meter size* triclamp ferrules are 1/2" larger than the meter size* triclamp ferrules are 1/2" larger than the meter size

    Process Connection Material Process Connection Material Process Connection Material Process Connection Material Process Connection Material Process Connection Material Process Connection Material Process Connection Material T threaded stainless steel C carbon steel flanges ( TP080+ ) S 316 stainless steel process connections

    No. of Pick-offsNo. of Pick-offsNo. of Pick-offsNo. of Pick-offsNo. of Pick-offs1 one2 two x 90 degree electrically offset (TP100+)

    Pick-off StylePick-off StylePick-off StylePick-off StylePick-off Style- 1 MS (military style) connector- 2 FL (flying leads)

    Pick-off TypePick-off TypePick-off TypePick-off Type1 standard coil ( 120C [250F] max.) 2 hermetically sealed or high temp coil3 intrinsically safe coil - ATEX Approved4 preamplified (MS connector only)

    LinearityLinearityLinearity1 +/-0.5% ( standard )2 +/-0.15% (custody transfer TP100+)

    Integral OptionsIntegral OptionsJB Junction box - ATEX ApprovedPA Exd preamplifier - ATEX ApprovedFI Exd F/I converter - ATEX Approved

    with scaleable pulse output B2 BT11 dual totaliser IECEx & ATEX approved B3 I.S. intrinsically safe BT11

    scaled pulse, alarms & 4~20mA R2 RT12 rate totaliser IECEx & ATEX approved R3 I.S. intrinsically safe RT12

    scaled pulse + backlighting R4 RT20 flow rate totaliserdc powered 2 stage batch controller E0 EB10 dc batch controller

    SB Specific build requirement M o d e l N o. E x a m p l e M o d e l N o. E x a m p l e M o d e l N o. E x a m p l e M o d e l N o. E x a m p l e M o d e l N o. E x a m p l e M o d e l N o. E x a m p l e M o d e l N o. E x a m p l e M o d e l N o. E x a m p l e

    TP025 S 1 T 1 - 2 1 1 R2

    FLANGED METERS THREADED METERSModel No. A Model No. B C

    TP010 127mm (5.0) TP010 64mm (2.5) 1/2 BSP or NPTTP012 127mm (5.0) TP012 64mm (2.5) 3/4 BSP or NPTTP015 127mm (5.0) TP015 64mm (2.5) 3/4 BSP or NPTTP020 140mm (5.0) TP020 83mm (3.3) 3/4 BSP or NPTTP025 152mm (6.0) TP025 89mm (3.5) 1 BSP or NPTTP040 178mm (7.0) TP040 115mm (4.5) 1 1/2 BSP or NPTTP050 197mm (7.8) TP050 133mm (5.5) 2 BSP or NPTTP080 254mm (10.0)TP100 356mm (14.0)TP150 368mm (14.5)TP200 457mm (18.0)TP250 457mm (18.0)TP300 457mm (18.0)TP400 610mm (24.0)TP500 610mm (24.0)

    Option Fitted HRT12/EB10 210mm (8.3)RT20/BC20 185mm (7.3)

    EX Junction Box 150mm (6.0)

    DIMENSIONS

    Junction Box, Exd PreamplifierExd F/I Converter Option

    RT12/EB10

    RT20/BC20

    Flanged meters available withA.N.S.I or din flanges. See applicablestandard for flange dimensions.

  • 14

    DUALPULSE insertion flowmeters

    DP490 & DP525 are cost effective stainless steel flowmeters for measuring the flow of water, fuels & other low viscosity liquids in pipes sizes 1.5~100 (40~2500mm).

    Insertion flowmeters are installed with the metering head 1/8th into the pipe resulting in very little pressure drop. They do not require external power when used with the Trimec rate totalisers however some options such as high temperature & non-magnetic models require external power.

    Applications include HVAC, hot & chilled water, fire systems, water distribution (management & treatment), boiler feed water & hydrant flow testing.

    FEATURES : IP68 (NEMA6) submersible 316SS construction. Low cost of ownership, wide flow range. Rugged & compact design. Intrinsically safe hazardous area versions. Integral or remote pre-amplifiers & flow instruments. DP525 version suitable for hot tap installation. BI-Directional Flow Measurement

    GENERAL SPECIFICATIONSGENERAL SPECIFICATIONSModel prefix : DP490 DP525

    Suit pipe sizes 40~900mm ( 1.5"~36") 50~2500mm (2"~100")Pipe connection 1.5" BSP or NPT 2" BSP or NPTFlow range 0.25 ~ 6300 litres/sec 0.4 ~ 49000 litres/sec

    ( 4 ~ 99600 USGM ) ( 6 ~ 780000 USGM )Flow velocity range 0.3 ~ 10 metres/sec ( 1 ~ 33 feet/sec )Linearity typically 1.5% with well established flow profifeTemperature range -40C ~ +100C ( -40F ~ +212F ) 200C max.Maximum pressure 80 bar ( 1200 psig )Materials 316SS body & rotor shaft, PVDF rotor Pulse outputs

    * Reed switch 30Vdc x 200mA max. Nom. 0~80hzHall effect 3 wire NPN, 5~24Vdc, 20mA max. Nom. 0~240hz

    Voltage Pulse self generated voltage. Nom. 0~240hzIntrinsically safe coil self powered, generates 15~3000mV

    High temperature coil self powered, 200C (390F) max.Non magnetic sensor 3 wire NPN, 5~24Vdc, 20mA max. Nom. 0~240hz

    Analog loop powered 4 ~ 20mA* Maximum thermal shock 10C (50F) / min. applies to the reed switch* Maximum thermal shock 10C (50F) / min. applies to the reed switch* Maximum thermal shock 10C (50F) / min. applies to the reed switch

    D U A L P U L S E P A D D L EW H E E L F L O W M E T E R S

  • 15www.trimecind.comfor individual data sheets:

    T E C H N I C A L I N F O R M A T I O ND U A L P U L S E F L O W M E T E R S

    MODEL CODINGDP490 1.5 to 36" pipes ( 40 ~ 900mm )DP525 2 to 100" pipes (50 ~ 2500mm) suitable for "hot-tap" installations

    Body materialBody materialBody materialBody materialBody materialS 316 Stainless Steel

    Rotor & bearing materialsRotor & bearing materialsRotor & bearing materialsRotor & bearing materialsRotor & bearing materialsRotor & bearing materialsRotor & bearing materialsRotor & bearing materials1 PEEK high temperature rotor - 200C (390F)2 PVDF rotor - 100C (212F) max ( standard ) 3 PVDF rotor with hastelloy shaft (for chlorinated waters)

    O-ring materialsO-ring materialsO-ring materialsO-ring materialsO-ring materials1 Viton ( standard ), -15~+204C ( 5~400F ) 2 EPR (Ethylene Propylene Rubber) for ketones only3 Teflon encapsulated viton - application specific 4 Buna-N ( Nitrile ), -65~+125C ( -53~+250F )

    Temperature limitsTemperature limitsTemperature limitsTemperature limitsTemperature limits5 100C (212F) standard2 125C (260F) - PEEK rotor only 3 150C (300F) - NPN output & PEEK rotor only 150C (300F) - NPN output & PEEK rotor only 150C (300F) - NPN output & PEEK rotor only 150C (300F) - NPN output & PEEK rotor only 150C (300F) - NPN output & PEEK rotor only 150C (300F) - NPN output & PEEK rotor only6 200C (390F) with output type 6 coil & PEEK rotor 200C (390F) with output type 6 coil & PEEK rotor 200C (390F) with output type 6 coil & PEEK rotor 200C (390F) with output type 6 coil & PEEK rotor 200C (390F) with output type 6 coil & PEEK rotor 200C (390F) with output type 6 coil & PEEK rotor

    Process connectionsProcess connectionsProcess connectionsProcess connections

    - 1 BSPT - 1"M ( DP490 ), 2"M ( DP525 )

    - 2 NPT - 1"M ( DP490 ), 2"M ( DP525 )

    - 3 2" BSPT male thread on the DP490

    - 4 2" NPT male thread on the DP490Pick-up typePick-up typePick-up type

    1 NPN hall effect & voltage pulse (standard)2 NPN open collector(s) 3 Reed switch only ( I.S. applications )4 Non magnetic rotor with NPN output5 Non magnetic rotor with I.S. coil output6 High temp. 200C (390F) coil output7 Non magnetic rotor for 125C (255F)

    Electrical connectionsElectrical connections1 3 metre (10ft) cable (std)2 10 metre (33ft) cable3 20 metre (66ft) cable4 50 metre cable (164ft)5 Terminal box on stem kit6 Stem kit

    Integral optionsQP Quadrature pulse output

    with scaleable pulse output B2 BT11 dual totaliser IECEx & ATEX approved B3 I.S. intrinsically safe BT11

    scaled pulse, alarms & 4~20mA R2 RT12 rate totaliser IECEx & ATEX approved R3 I.S. intrinsically safe RT12

    scaled pulse + backlighting R4 RT20 large LCD rate totaliserdc powered 2 stage batch controller E0 Batch controller

    Requires electrical connection 5 FI Loop powered 4~20mA outputSB Specific build requirement

    M o d e l N o. E x a m p l e

    DP490 S 2 1 5 - 1 1 6 R2Ball or Gate Valve: Female 2 NPT or BSPT Connections.Note minimum internal diameter to be 40mm

    2 NPT or BSPT Nipple

    Female 2 NPT or BSPT threadolet.Note minimum internal diameter to be 40mm

    Model 525Dual PulseFlow Meter

    HOT TAP INSTALLATION

    STANDARDINSTALLATION

    PIPE ID

  • 16

    GENERAL SPECIFICATIONSGENERAL SPECIFICATIONSModel prefix : Flowmeter Batch system

    Nominal size 20mm ( 3/4" BSP or NPT male threaded )Flow range 1 ~ 70 litres/min ( 0.3 ~ 18 USGM )Accuracy 1.5% of reading (70:1 turndown) 0.5% for 20:1Temperature range 5C ~ 90C ( 40F ~ +194F ) - 10bar ( 150psi )Maximum pressure 10 bar (150 psig)Power requirement self powered or 5~30Vdc 24VdcProtection class IP 66.67, optional I.S. IP 66/67 (NEM A 4X)Materials brass body, PP impeller with ruby bearing

    Electrical (see also optional outputs)Output pulse resolution Reed switch & Hall Effect 20 PPL (76 PPG)* Reed switch output 30Vdc x 200mA max.Hall effect output 3 wire NPN open collector, 5~24Vdc, 20mA max.

    * Maximum thermal shock 10C (50F) / min. applies to the reed switch

    BlindPulse Meter

    Rate Totaliser

    CompleteBatchingSystem

    BatteryTotaliser

    I M P E L L E R F L O W M E T E R SA N D P A C K A G E D A S S E M B L I E S

    UTILITY tangential flowmeters

    The UM series is specifically engineered for the most common liquid transfer and monitoring applications within industrial plants, mining sites, automotive service centers and refueling installations.

    Monitoring & controlling the movements of water, fuels & other low viscosity liquids under pumped or gravity conditions in small pipe sizes is widespread. The UM flowmeter provides a cost effective & reliable solution with a variety of versatile options.

    FEATURES : High accuracy & repeatability. Low cost of ownership, wide flow turndown. Rugged & compact design. Intrinsically safe hazardous area versions. Integral flow conditioning & strainer.

    STANDARD OPTIONS : LCD totaliser-batch totaliser, flow rate totalisers, scaled pulse, 4~20mA & flow alarm outputs, packaged electronic batch control system and pulse processing modules.

  • 17www.trimecind.comfor individual data sheets:

    HIGH PRESSURE METERSTrimec produce a number of meters for various high pressure applications within the exploration, hydraulic, lubrication, marine & mining industries. From the flow range chart opposite one can select a particular meter which best suits their piping & flow range requirements.

    Trimec standard high pressure meters are stainless steel; intermediate pressure meters in alternate materials are produced to suit the specific needs of the customer.

    STANDARD OPTIONS : Integral and remote preamplifier, LCD totaliser-batch totaliser, flow rate totalisers, scaled pulse, 4~20mA & flow alarm outputs, electronic batch controllers and pulse processing modules.

    SPECIFIC BUILD METERSIt is not uncommon for a customer to have a flow application which requires a tailored solution. Trimec maintains a specific build register of the many flowmeter design variations which have been provided to customers over the past 20 years.

    Design variables have included special process & electrical connections, high temperature meters, sub sea meters, tropicalised electronics & many other non standard constructions in accordance with the customers specific requirements.

    HIGH PRESSURE OVAL PD METERS (for all viscosities)

    Flow range Pressure Size Model PageLitres/hr (GPH) bar (PSIG)

    0.5~36 (0.13~9.5) 400 (5580) 4mm (1/8") MG004H 62~100 (0.5~27) 400 (5580) 6mm (1/4") MG006H 615~550 (4~145) 400 (5580) 6mm (1/4") MG008H 6

    Litres/min (GPM)1~40 (0.26~10.6) 400 (5580) 15mm (1/2") MG015H 810~150 (2.6~40) 400 (5580) 25mm (1") MG025H 815~250 (2.6~66) 400 (5580) 40mm (1.5") MG040H 830~450 (4~120) 300 (4410) 50mm (2") MG050H 8

    HIGH PRESSURE PISTON PD METERS (for all viscosities)Flow range Pressure Size Model Page

    Litres/min (GPM) bar (PSIG)0.2~10 (0.05~2.7) 350 (5145) 15mm (1/2") MP015H 4

    2~50 (0.5~13) 200 (2940) 25mm (1") MP025H 44~140 (1.1~37) 250 (3675) 40mm (1.5") MP040H 4

    HIGH PRESSURE TURBINE METERS (maximum viscosity 65cst)Flow range Pressure Size Model Page

    Litres/min (GPM) bar (PSIG)13~133 (3.5~35) 400 (5580) 20mm (3/4") TP020H 1227~270 (7~70) 400 (5580) 25mm (1") TP025H 12

    57~570 (15~150) 400 (5580) 40mm (1.5") TP040H 12

    Heat JacketedOval PD Meters

    High PressureTurbine Meters

    High Pressure OvalPD Meters

    High Pressure-High Viscosity Piston PD

    Meters

    Specific BuildPD Meters

    H I G H P R E S S U R E A N DS P E C I F I C B U I L D F L O W M E T E R S

  • 18

    S P E C I A L T Y P . D . F L O W M E T E R S

    AIM additive injection manifold

    AIM block is a compact all stainless steel manifold assembly complete with isolating, flow regulating & check valves, a fine mesh strainer, solenoid valve & a precision oval gear flowmeter.

    AIM injects small amounts of modifying additives & performance enhancing agents into fuels & base product, these include lubricants, dyes, colorings, denaturants, detergents, odorizing, anti-freeze, anti-corrosion, anti-static, anti-detonating, anti-icing, anti-foaming and emulsifiers.

    FUEL CONSUMPTION METERS

    Trimec compact fuel consumption meters are specifically designed for fuel flow in open & return loop fuel injection systems, they provide accurate instantaneous fuel consumption readings on petrol, diesel & fuel oil fired engines of all sizes. A special feature is available which offsets the effects of flow pulsations from injectors.

    BURNER BLOCKS for packaged boilers

    Boiler manufacturers generally supply a fuel consumption flow meter as part of their package. Trimec can produce a meter with a base footprint which attaches directly to the manufacturers combustion head thereby avoiding the need for external piping.

    SAP METERS super acid proof

    Multipulse SAP positive displacement meters provide high levels of accuracy for dispensing batches of acids and chemicals which react with metals. Applications include photographic solutions, pool chemical container filling systems & wet cell battery manufacturing.

    AIM general specificationsModel prefix : AIM004 AIM006 AIM008

    Process connections 3/8"NPT elbows, 3 x 90 orientation positions 3/8"NPT elbows, 3 x 90 orientation positions 3/8"NPT elbows, 3 x 90 orientation positions Flow range litres / min 0.01 ~ 1.0 0.03 ~ 1.66 0.25 ~ 10 US gal / min 0.002 ~ 0.27 0.008 ~ 0.44 0.07 ~ 2.65Pulse / Litre 2800 (11220) 1050 (4200) 710Pulse / US gal (Optional) 10600 (42470) 4000 (15900) 2

    EM Mini FuelEM Mini FuelConsumptionConsumption

    MetersMeters(Patent Applicable)

    EM FuelEM FuelConsumptionConsumption

    MetersMeters(Patent Applicable)

    All speciality PD flowmeters accuracies typically better than +/-0.5% of reading (application dependent).

    AIM AdditiveInjection Block

    Fuel OilBurner Block for

    Packaged Boilers

    EM & FM fuel consumption metersModel prefix : EM006A EM008A EM020 EM025

    Normal size 5mm (1/4) 8mm (3/8) 20mm (3/4) 25mm (1) Flow range litres / hr 2 ~ 100 15 ~ 550 60 ~ 2400 120 ~ 6000 US gal / hr (0.5 ~ 27) (4 ~ 145) (16 ~ 630) (30 ~ 1600)Engine size to 500 HP 2800 HP 12000 HP 30000 HP

    BURNER BLOCK general specificationsModel prefix : BB025

    Flow range (fuel oil) 1 ~ 50 liters/min (0.26 ~ 13.2 USGM)Materials Aluminum or 316 Stainless Steel

    SUPER ACID PROOF (SAP) meters (see page 5 for full details)Model prefix : MP010P MP020P

    Normal size 8mm (3/8) BSP 20mm (3/4) BSPFlow range - L/min (USGM) 0.2 ~ 10 (0.05 ~ 2.7) 2 ~ 50 (0.5 ~ 13)

  • 19www.trimecind.comfor individual data sheets:

    F L O W I N S T R U M E N T S

    FLOW RATE TOTALISERS battery powered

    Trimec offer two models, the RT12 is more orientated towards the process control industry providing a range of analog & digital outputs compatible with PLCs & other plant control equipment. The new RT20 has larger digits specifically suited for liquid transfer applications requiring high visibility & back lighting.

    BATCH CONTROLLERS for digital inputs

    The EB Ecobatch is fully programmable a two stage pre-set batch controller with high speed counting & automatic overrun compensation. Applications include bottle & container filling, loading systems & batch mixing.

    BATTERY TOTALISER low cost & compact

    Providing resettable & accumulative totals on two lines of display, the BT11 is also available with intrinsically safe approval.

    PULSE PROCESSING MODULES

    The PD2 is a pulse discriminator for by-directional flow applications, the PR2 is a pulse repeater interface for high loads & the PC1 minature interface board converts an NPN solid state output to a PNP pulse output.

    PULSE TO ANALOG The FI420 is a programmable 4~20mA frequency to current converter which fits within any Trimec flowmeter.

    GENERAL SPECIFICATIONSGENERAL SPECIFICATIONSModel prefix : BT11 RT12 RT20 EB10

    Function DualtotaliserRate

    totaliserRate

    totaliserBatch

    controller Power source

    battery powered yes yes yes no8~24Vdc external power yes yes yes yes

    4~20mA loop powered no yes no no LCD display - line 1 1 x 7.5mm 1 x 9mm 1 x 17mm 1 x 9mm

    - line 2 1 x 3.6mm - 1 x 7mm -accumulative total yes yes yes yes

    resettable total yes yes yes norate display no yes yes nobacklighting optional optional standard optional

    Input typesun-powered sensors reed switch, coil (15mV P-P min.),

    powered sensors open collector, current pulse, namur & proximitieslow frequency cut-off no yes yes no

    dual flow inputs no yes no no10 point linearisation no yes no no

    Outputs4~20mA output (750) no yes no nohigh & low flow alarms NPN / PNP NPN / PNP NPN NPN / PNP

    scaleable pulse NPN / PNP NPN / PNP NPN NPN / PNPdual SPCO relay board no optional (replaces solid state outputs)optional (replaces solid state outputs)optional (replaces solid state outputs)

    Power sourceIP66/67 ( NEMA 4X ) yes yes yes yesDIN mount (optional) no yes yes yes

    intrinsically safe (optional) yes yes no noExd Explosionproof (optional) no yes no yesExd Explosionproof (optional) no yes no yes

    STANDARD OPTIONS : The above instruments are supplied in either field, pipe or panel mount configurations with some being available with either Aluminum or stainless steel Exd explosion proof housings.

    4~20mA4~20mAOutput Board

    RT20 Universal Mount

    Explosion ProofExplosion ProofInstruments

    PackagedPackagedBatchingBatchingSystems

    RT20 MeterRT20 MeterMount

    UniversalUniversalMountMount

    Instruments

    MechanicalMechanicalRegister

    Totaliser

    DIN Panel MountDIN Panel MountInstruments

    Relay Interface

    PR2 & PD2 PulsePR2 & PD2 PulseProcessing Modules

  • 20

    C U S T O D Y T R A N S F E R

    GENERAL SPECIFICATIONSGENERAL SPECIFICATIONSMeter Size : 1 1.5 2 3 4

    Meter Material aluminumMinimum delivery (liters) 5 10 20 50 200Maximum flow (L/min) 150 250 450 1500 2500Mechanical registers Reset & Preset with optional printerMechanical control Two stage mechanical cut-off valveMaximum pressure 10 bar (147psig)

    Strainer

    WaferCheckValves

    Modular Flange Portions

    STRAINERS & AIR ELIMINATORS

    The modular design of the strainers & optional air eliminator head allow fitment as a stand alone or close coupled strainer only or as a multi function strainer air eliminator check valve assembly.

    Wafer back pressure check valves are fitted between the eliminator strainer (ES) and the flowmeter to aid in the extraction of air & prevent any possibility of reverse flow.

    MECHANICAL METERING ASSEMBLIES

    Meters 1~4 fitted with an angle adaptor will take various combinations of large mechanical registers, presets registers, printers & associated check & cut-off valves.

    Strainer with air eliminator

    GENERAL SPECIFICATIONSGENERAL SPECIFICATIONSModel prefix : MG025 MG040 MG050 MG080E MG100

    Nominal size ( inches ) 1" 1.5" 2" 3" 4"Materials aluminum bodyMinimum delivery (liters) 5 10 20 50 200Maximum flow (L/min) 150 250 450 1000 *1500Output options Reed Switch & NPN Hall, Quadrature HallsMaximum pressure 10 bar (147psig)

    CUSTODY TRANSFER CLASS METERS

    Medium & large capacity meters are supplied in the form of custody transfer assemblies incorporating peripheral devices to meet the requirements of industry and relevant approval bodies.

    GENERAL SPECIFICATIONSGENERAL SPECIFICATIONSModel prefix : ES025 ES040 ES050 ES080 ES100

    Nominal size ( inches ) 1" 1.5" 2" 3" 4"Materials aluminum body, 316SS basket, viton sealsStrainer mesh sizes 100 mesh (150 micron)Maximum pressure 10 bar (147psig)Air release head Dual port double reed valveVenting capacity @ 10psig 154 CFM (4.36M 3/min @ 70kpa)

    Pulse meter with wafercheck valve,

    air eliminator & strainer

    Meter with wafer check valve, air eliminator,

    strainer & mechanicalpre-set cut off valve

  • 21www.trimecind.comfor individual data sheets:

    A P P L I C A T I O N S A N DL I Q U I D C H A R A C T E R I S T I C S

    VISCOUS LIQUID BEHAVIOR

    The viscosity of a liquid is proportional to its resistance to shear. Of the three categories of viscosity (see opposite) Newtonians are most typical and include petroleum fluids, water & similar chemicals.

    Most empirical test data for flowmeters and pumps has been developed using Newtonian liquids. When working with Non-Newtonian liquids we use the expression effective viscosity in terms of the liquid after it has been pre-sheared by the pump and subsequent movement through the pipe , in these instances it is not unusual for the effective viscosity to be many times less than the theoretical viscosity thereby lessening the pressure drop across the meter.

    PRESSURE DROP LIMITATIONS ON PD FLOWMETERS

    Positive displacement flowmeters are an inexpensive means to accurately meter high viscosity clean liquids as high as 1 million centipoise however, the appropriate meter must be sized so that the pressure drop across the primary measuring elements (oscillating piston or oval rotor), does not exceed the maximum capability of either.

    The oscillating piston meter can withstand 4 bar differential making it more suitable to high viscosity liquids, the oval meter is limited to 1 bar differential due to the pressure imposed on the rotor shafts.

    Viscosities Maximum flow multiplier for PD metersLess than Standard oval gear Special cut oval gear Oscillating piston1,000 cp 1 1.00 1.002,000 cp 0.50 1.00 1.004,000 cp 0.42 0.84 0.906,000 cp 0.33 0.66 0.808,000 cp 0.25 0.50 0.7030,000 cp 0.15 0.30 0.6060,000 cp 0.12 0.25 0.50150,000 cp 0.10 0.20 0.40250,000 cp 0.05 0.10 0.15

    1,000,000 cp 0.025 0.05 0.08

    FLOW RATE DE-RATING GUIDE FOR PD METERS

    TYPICAL METERED LIQUIDS & VISCOSITY TYPESLiquid SG cp Key Liquid SG cp Key Liquid SG cp Key

    ADHESIVES DAIRY PAPER & TEXTILESBox Adhesives 1.00 3000 T Cottage Cheese 1.08 225 N Black Liquor tar 2000 @ 150CPVA 1.30 100 T Creme 1.02 20 @ 5C D Paper Coating 35% 400

    BAKERY Milk 1.0 1.2 @ 15C T Sulfide 6% 1600Butter - melted 0.98 18 @ 60C N Cheese, Process 30000 @ 70C N Black Liquor 1.30 1100 @ 50CEgg, Whole 0.50 60 @ 10C N Yogurt 1100 T Black Liquor Soap 7000 @ 50CFrosting 1.0 10000 T FATS & OILS PETROLEUMLecithin 3250 @ 50C T Corn Oil 0.92 30 N Bitemen 60 @ 180CCondensed Milk 1.30 10000 @ 25C N Lard 0.92 60 @ 40C N Gasoline 0.70 0.8 @ 15C NYeast Slurry 15% 1.00 180 T Linseed Oil 0.93 30 @ 40C N Keroseen 0.80 3 @ 18C N

    BEER Peanut Oil 0.92 42 @ 40C N Fuel Oil # 6 0.90 660 @ 50C NBeer 1.00 1.1 @ 5C N Soybean Oil 0.95 36 @ 40C N SAE 40 lube oil 0.90 200 @ 40C NYeast 80% solids 16000 @ 5C T Vegetable Oil 0.92 3 @ 150C N SAE 90 lube oil 0.90 320 @ 40C N

    CONFECTIONARY FOODS Propane 0.46 0.2 @ 40C NCaramel 1.20 400 @ 60C Black Bean Paste 10000 T Bunker-C fuel oil 0.93 1500 @ 15C NChocolate 1.10 17000 @ 50C T Cream Style Corn 130 @ 90C T PHARAMACEUTICALSFudge, Hot 1.10 36000 T Tomato Sause 1.11 560 @ 60C T Caster Oil 0.96 350 NToffee 1.20 87000 T Tomato Paste 33% 1.14 7000 T Cough Syrup 1.00 190 N

    COSMETICS, SOAPS Pablum 4500 T PLASTICS & RESINSFace Cream 10000 T Pear Pulp 4000 @ 70C T Polyster Resin 1.40 3000Hair Gel 1.40 5000 T Potato Mashed 1.00 20000 T PVA Resin 1.30 65000 TShampoo 5000 T Prune Juice 1.00 60 @ 50C T SUGAR SYRUPSToothpaste 20000 T Orange Juice Conc 1.10 5000 @ 3C T Glucose 1.42 10000 @ 40CHand Cleanser 20000 T Mayonnaise 1.00 5000 @ 24C T Molassas - A 1.44 280~5k @ 40C

    DETERGENTS Honey 1.50 15000 @ 40C T Molassas - B 1.46 1k~13k @ 40CConcentrate 10 N PAINT Molassas - C 1.47 3k~6k @ 40C

    DYES & INKS Auto Paint 20000 T 60 Brix 1.29 75 @ 15C NInk, Printers 1.38 10000 T Solvents 0.8~0.9 0.5 to 10 N 68 Brix 1.34 360 @ 15C NDye 1.10 10 N Varnish 1.06 140 @ 40C T 76 Brix 1.39 4000 @ 15C NSolvents 0.8~0.9 0.5 to 10 N Turpentine 0.86 2 @ 15C N Corn syrup 1.39 15000 @ 15C

    Centistokes x SG = Centipoise (cp) Centipoise / SG Centistokes (cSt)

  • 22

    O V A L G E A R M E T E RC H A R A C T E R I S T I C S

    PRESSURE DROP LIMIT VERSES FLOW RATE

    The curves below represent the pressure drop for standard and special cut high viscosity oval rotors at various viscosities. Special cut rotors have alternate tooth relieve which effectively reduces the pressure drop by 50%.

    Viscosities are in centipoise and the pressure drop is in Bar (1 Bar = 14.7psig). When sizing an oval meter for viscous liquids be sure your selection falls on or below the 1 bar maximum allowable pressure drop line on the graph.

    Standard Rotors Special Cut Rotors

    ACCURACY CURVES & PRESSURE DROP

    PRESSURE DROP CURVES FOR STANDARD & SPECIAL CUT OVAL ROTORS

  • 23www.trimecind.comfor individual data sheets:

    C A L I B R A T I O NC E R T I F I C A T I O N SA N D A P P R O V A L S

    CALIBRATION PD & Turbine flowmeters

    All Trimec positive displacement (PD) and turbine flowmeters are flow tested and each is supplied with an individual calibration certificate as shown. Calibration is traceable to the National Measurements Institute (NMI) Australia.

    Turbine flowmeters are calibrated over 5 points in keeping with applications on low viscosity liquids whilst PD flowmeters, due to their application on a wide range of liquid viscosities, are calibrated at one point, multipoint calibration for PD meters is available on request at an additional charge.

    CERTIFICATIONS meters & flow instruments

    Trimec is a quality certified company and manufacturer holding a number of approvals which qualify much of the propriety product range for safe application within hazardous, safe & aggressive industrial environments throughout the world, these include:

    FLAMEPROOF APPROVAL (Exd)

    IECEx. ATEX Exd IIB T6 (60C) & T4 IP66 / IP67Oval Gear & Oscillating Piston positive displacement flowmeters.

    INTRINSICALLY SAFE APPROVAL (I.S.)

    IECEx. ATEX EEx ia IIB T4 (Tamb=60C) IP66 / IP67Self powered & externally powered flow reading instruments, meter or remote mounted.

    CE & EMI / EMC CONFORMITY

    Applies to all product produced by Trimec.

    PED PRESSURE DIRECTIVE

    Product conforms to directive 97/23/EC pressure equipment.

    RoHS WEEE CONFORMITY

    All electronic product conforms to RoHS & WEEE green regulation directive for monitoring & control instruments.

    AUSTRALIAN NMI APPROVAL

    National Measurements Institute Custody Transfer approval applies to Trimec medium & large capacity Oval Gear flowmeters.

    AS/NZS ISO 9001:2008 QUALITY ASSURANCE APPROVAL

    Quality management system for design & manufacture.

  • Available From:

    SLRANGE - 3809

    Proudly the Trimec facility is ISO9001:2008 quality certified for design & manufacture.

    Innovative engineering & features can be attributed to 150 combined years of flow metering experience coming from the Trimec design team.

    Sydney AustraliaPh. +612 9540 4433 Fax. +612 9525 9411Email: [email protected] www.trimecind.com.au

    Sydney Australia