Transmission Electron Microscopy Laboratory Portfolio · Biological Figure 3. Transmission electron...

17
Transmission Electron Microscopy Laboratory Portfolio Daniel Fougnier 4/29/2019 Submitted for MCR 485/683 Transmission Electron Microscopy Spring 2019 N.C. Brown Center for Ultrastructure Studies

Transcript of Transmission Electron Microscopy Laboratory Portfolio · Biological Figure 3. Transmission electron...

Page 1: Transmission Electron Microscopy Laboratory Portfolio · Biological Figure 3. Transmission electron micrograph of mouse kidney tissue. Thin sections were stained with uranyl acetate

Transmission Electron Microscopy Laboratory Portfolio

Daniel Fougnier

4/29/2019

Submitted for MCR 485/683 Transmission Electron Microscopy

Spring 2019 N.C. Brown Center for Ultrastructure Studies

Page 2: Transmission Electron Microscopy Laboratory Portfolio · Biological Figure 3. Transmission electron micrograph of mouse kidney tissue. Thin sections were stained with uranyl acetate

2

These images were prepared as part of the class MCR 485/683 Transmission Electron

Microscopy at S UNY College of Environmental S cience and Forestry, S pring 2019

A ll images were acquired on the JEOL JEM

2100F Transmission Electron Microscope in the N. C . B rown Center for Ultrastructure S tudies

Page 3: Transmission Electron Microscopy Laboratory Portfolio · Biological Figure 3. Transmission electron micrograph of mouse kidney tissue. Thin sections were stained with uranyl acetate

Images of Biological and Materials Samples

This portfolio includes a set of micrographs from lab sessions demonstrating proper specimen preparation and imaging.

3

Biological ● Mouse Kidney

■ Fixed in glutaraldehyde and osmium tetroxide

■ Embedded in A raldite

■ S tained w ith uranyl acetate and lead citrate

Materials ● S ilver Nanopow der ● Copper Nanopow der

■ 1 mg/mL suspension of nanopow der in deionized w ater, sonicated for 30 minutes

■ 1 drop of nanopow der suspension evaporated onto Formvar coated grid

Page 4: Transmission Electron Microscopy Laboratory Portfolio · Biological Figure 3. Transmission electron micrograph of mouse kidney tissue. Thin sections were stained with uranyl acetate

4

Figure 1. Transmission electron micrograph of mouse kidney tissue. Thin sections were stained with uranyl acetate and lead citrate, image was acquired with 200kV at 8kX. This micrograph features mitochondria (M), and a leukocyte (B ) within a capillary blood vessel (C). B ar=1µm

Biological

Page 5: Transmission Electron Microscopy Laboratory Portfolio · Biological Figure 3. Transmission electron micrograph of mouse kidney tissue. Thin sections were stained with uranyl acetate

5

Biological

Figure 2. Transmission electron micrograph of mouse kidney tissue. Thin sections were stained w ith uranyl acetate and lead citrate, image was acquired w ith 200kV at 8kX. This micrograph features an erythrocyte (E) and a thrombocyte (P) w ithin a capillary (C). Bar=1µm

Page 6: Transmission Electron Microscopy Laboratory Portfolio · Biological Figure 3. Transmission electron micrograph of mouse kidney tissue. Thin sections were stained with uranyl acetate

6

Biological

Figure 3. Transmission electron micrograph of mouse kidney tissue. Thin sections were stained w ith uranyl acetate and lead citrate, image was acquired w ith 200kV at 8000X. This image features a cell nucleus. The nucleolus (Nu), nuclear membrane (M), a nuclear pore (P), heterochromatin (HC), and euchromatin (EC) are labelled. B ar=1µm

Page 7: Transmission Electron Microscopy Laboratory Portfolio · Biological Figure 3. Transmission electron micrograph of mouse kidney tissue. Thin sections were stained with uranyl acetate

7

Biological

Figure 4. Transmission electron micrograph of mouse kidney tissue. Thin sections were stained w ith uranyl acetate and lead citrate, image was acquired w ith 200kV at 12kX. This image features a cell nucleus. The nucleolus (Nu), nuclear membrane (M), and heterochromatin (HC) are labelled. B ar=1000nm

Page 8: Transmission Electron Microscopy Laboratory Portfolio · Biological Figure 3. Transmission electron micrograph of mouse kidney tissue. Thin sections were stained with uranyl acetate

8

Biological

Figure 5. Transmission electron micrograph of mouse kidney tissue. Thin sections were stained w ith uranyl acetate and lead citrate, image was acquired w ith 200kV at 6000X. This image features a capillary blood vessel (C), a renal filtration membrane (F), and several mitochondria (M). B ar=2µm

Page 9: Transmission Electron Microscopy Laboratory Portfolio · Biological Figure 3. Transmission electron micrograph of mouse kidney tissue. Thin sections were stained with uranyl acetate

9

Biological

Figure 6. Transmission electron micrograph of mouse kidney tissue. Thin sections were stained w ith uranyl acetate and lead citrate, image was acquired w ith 200kV at 12kX. This image features several mitochondria (M) within renal filtration membranes. B ar=1000nm

Page 10: Transmission Electron Microscopy Laboratory Portfolio · Biological Figure 3. Transmission electron micrograph of mouse kidney tissue. Thin sections were stained with uranyl acetate

10

Biological

Figure 7. Transmission electron micrograph of mouse kidney tissue. Thin sections were stained w ith uranyl acetate and lead citrate, image was acquired w ith 200kV at 25kX. This image features two mitochondria (M) with visible christae (Ch). B ar=500nm

Page 11: Transmission Electron Microscopy Laboratory Portfolio · Biological Figure 3. Transmission electron micrograph of mouse kidney tissue. Thin sections were stained with uranyl acetate

11

Materials

Figure 8. Transmission electron micrograph of silver nanopowder. Grids were prepared by evaporation of a drop of 1mg/mL suspension of nanopowder in deionized water. Image was acquired w ith 200kV at 15kX. This image features an overview of silver nanoparticle clusters, labelled Ag. B ar=500nm

Page 12: Transmission Electron Microscopy Laboratory Portfolio · Biological Figure 3. Transmission electron micrograph of mouse kidney tissue. Thin sections were stained with uranyl acetate

12

Materials

Figure 9. Transmission electron micrograph of silver nanopowder. Grids were prepared by evaporation of a drop of 1mg/mL suspension of nanopowder in deionized water. Image was acquired w ith 200kV at 100kX. This image features an overview of a single cluster of silver nanoparticles, labelled Ag. A tomic lattice moire pattern labelled ML. B ar=200nm

Page 13: Transmission Electron Microscopy Laboratory Portfolio · Biological Figure 3. Transmission electron micrograph of mouse kidney tissue. Thin sections were stained with uranyl acetate

13

Materials

Figure 10. Transmission electron micrograph of silver nanopowder. Grids were prepared by evaporation of a drop of 1mg/mL suspension of nanopowder in deionized water. Image was acquired w ith 200kV at 150kX. This image features an overview of a single silver nanoparticle, labelled Ag. B ar=50nm

Page 14: Transmission Electron Microscopy Laboratory Portfolio · Biological Figure 3. Transmission electron micrograph of mouse kidney tissue. Thin sections were stained with uranyl acetate

14

Materials

Figure 11. Transmission electron micrograph of silver nanopowder. Grids were prepared by evaporation of a drop of 1mg/mL suspension of nanopowder in deionized water. Image was acquired w ith 200kV at 1.2MX. This image features atomic lattice resolution of a single silver nanoparticle, labelled Ag (approximate diameter 24nm). A tomic lattice labelled Lat . B ar=10nm

Page 15: Transmission Electron Microscopy Laboratory Portfolio · Biological Figure 3. Transmission electron micrograph of mouse kidney tissue. Thin sections were stained with uranyl acetate

15

Materials

Figure 12. Transmission electron micrograph of silver nanopowder. Grids were prepared by evaporation of a drop of 1mg/mL suspension of nanopowder in deionized water. Image was acquired w ith 200kV at 1.2MX. 100% crop of Figure 9 depicting resolution of the atomic lattice structure.

Page 16: Transmission Electron Microscopy Laboratory Portfolio · Biological Figure 3. Transmission electron micrograph of mouse kidney tissue. Thin sections were stained with uranyl acetate

16

Materials

Figure 13. Transmission electron micrograph of copper nanopowder. Grids were prepared by evaporation of a drop of 1mg/mL suspension of nanopowder in deionized water. Image was acquired w ith 200kV at 200kX. Image depicts copper particles (Cu) encased in poly(vinyl alcohol) dispersant (PVA). B ar=50nm.

Page 17: Transmission Electron Microscopy Laboratory Portfolio · Biological Figure 3. Transmission electron micrograph of mouse kidney tissue. Thin sections were stained with uranyl acetate

17

Materials

Figure 14. Transmission electron micrograph of copper nanopowder. Grids were prepared by evaporation of a drop of 1mg/mL suspension of nanopowder in deionized water. Image was acquired w ith 200kV at 800kX. Image depicts copper particles (Cu) encased in poly(vinyl alcohol) dispersant (PVA). B ar=10nm.