Product Specifications OUTDOOR UNIT POWER CONNS. — V/PH/HZ MIN. BRCH. CIR. AMPACITY BR. CIR. PROT. RTG. - MAX. (AMPS) COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZ R.L. AMPS - L.R. AMPS FACTORY INSTALLED START COMPONENTS INSULATION/SOUND BLANKE T COMPRESSOR HEAT OUTDOOR FAN DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM @ 0.0 IN. W.G. NO. MOTORS - HP MOTOR SPEED R.P.M. VOLTS/PH/HZ F.L. AMPS OUTDOOR COIL — TYPE ROWS - F.P.I. FACE AREA (SQ. FT.) REFRIGERANT CONTROL REFRIGERANT LBS. R-410 (O.D. UNIT) FACTORY SUPPLIED LINE SIZE - IN. O.D. GAS LINE SIZE - IN. O.D. LIQ. CHARGING SPECIFICATION DIMENSIONS CRATED (IN.) WEIGHT SHIPPING (LBS.) NET (LBS.) J4AC6060A1000AA TAG: _________________________________ 5.0 Ton Split System Air Conditioner - 1 Phase J4AC6060A1000AA SUBMITTAL J4AC6060A1000AA 208/230/1/60 29.9 50 SCROLL 1 - 1 208/230/1/60 21.8-127.1 NO PROPELLER 23-5/8 - 1 DIRECT-1 3550 1 - 1/3 1050 208/230/1/60 2.60 MICROCHANNEL 1 - 23 18.4 ORIFICE 6 LBS. - 14 OZ. YES 7/ 8 3/8 W X H X D 30-1/5x38-63/64x30-1/5 225 192 NO NO J4AC6060A1000AA Model H W L LIQUID VALVE SIZE GAS VALVE SIZE 843 (33-3/16) 740 (29-1/8) 3/8 7/8 NOTE: All dimensions are in mm/inches. 740 (29-1/8) SUCTION LINE CONNECTION CONTROL WIRING 7/8” (22.2mm) KNOCKOUT 1-11/32” (34.5mm) LIQUID LINE CONNECTION SERVICE FITTING SERVICE FITTING POWER WIRING SEE DETAIL A DETAIL A HOLE 1-3/32” (27.8mm) NOTE: GRILL APPEARANCE MAY VARY. SERVICE ACCESS ALLOW 24” CLEARANCE AIR INLETS LOUVERED PANELS ALLOW 12” MINIMUM CLEARANCE W ACCESS VALVLE FOR LOW PRESSURE NOTE: ONLY ADOPTED BY HEAT PUMP, CAN BE USED FOR MEASURING PRESSURE AFTER SWITCHOVER VALVE-SUCTION TO COMPRESSOR OR REFRIGERANT CHARGE. See Table

Transcript of Trane Submittal - 3 Split System Heat Pump Model 1 …...Scroll Compressor Condenser Coil Optional...

Page 1: Trane Submittal - 3 Split System Heat Pump Model 1 …...Scroll Compressor Condenser Coil Optional accessories Liquid line drier — The J4AC60 is fully charged from the factory. This

Product Specifications OUTDOOR UNIT

POWER CONNS. — V/PH/HZ MIN. BRCH. CIR. AMPACITY BR. CIR. PROT. RTG. - MAX. (AMPS)

COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZ R.L. AMPS - L.R. AMPS FACTORY INSTALLEDSTART COMPONENTS INSULATION/SOUND BLANKE TCOMPRESSOR HEAT

OUTDOOR FAN DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM @ 0.0 IN. W.G. NO. MOTORS - HP MOTOR SPEED R.P.M. VOLTS/PH/HZ F.L. AMPS

OUTDOOR COIL — TYPE ROWS - F.P.I. FACE AREA (SQ. FT.) REFRIGERANT

CONTROL

REFRIGERANT

LBS.

R-410

(O.D.

UNIT)

FACTORY

SUPPLIED

LINE

SIZE

- IN.

O.D.

GAS

LINE

SIZE

- IN.

O.D.

LIQ.

CHARGING

SPECIFICATION

DIMENSIONS

CRATED

(IN.)

WEIGHT

SHIPPING

(LBS.)

NET

(LBS.)

J4AC6060A1000AA

TAG:

_________________________________

5.0 Ton Split SystemAir Conditioner - 1 Phase J4AC6060A1000AA

S UBMITTAL

J4AC6060A1000AA208/230/1/60

29.950

SCROLL1 - 1

208/230/1/6021.8-127.1

NOPROPELLER23-5/8 - 1DIRECT-1

35501 - 1/31050

208/230/1/602.60

MICROCHANNEL1 - 2318.4

ORIFICE

6 LBS.

- 14 OZ.

YES7/83/8

W

X

H

X D30-1/5x38-63/64x30-1/5

225192

NONO

J4AC6060A1000AA

Model H W L LIQUID VALVE SIZE GAS VALVE SIZE

843 (33-3/16) 740 (29-1/8) 3/8 7/8

NOTE: All dimensions are in mm/inches.

740 (29-1/8)

SUCTION LINE CONNECTION

CONTROL WIRING 7/8” (22.2mm)

KNOCKOUT 1-11/32” (34.5mm)

LIQUID LINE CONNECTION

SERVICE FITTING

SERVICE FITTING

POWER WIRING SEE DETAIL A

DETAIL A

HOLE 1-3/32” (27.8mm)

NOTE: GRILL APPEARANCE MAY VARY.

SERVICE ACCESS ALLOW 24” CLEARANCE

AIR INLETS LOUVERED PANELS ALLOW 12” MINIMUM CLEARANCE

W

ACCESS VALVLEFOR LOW PRESSURENOTE: ONLY ADOPTED BY HEAT PUMP, CAN BE USED FOR MEASURING PRESSURE AFTER SWITCHOVER VALVE-SUCTION TO COMPRESSOR ORREFRIGERANT CHARGE.

See Table

Page 2: Trane Submittal - 3 Split System Heat Pump Model 1 …...Scroll Compressor Condenser Coil Optional accessories Liquid line drier — The J4AC60 is fully charged from the factory. This

ModeCooling

Liquid Pressrue at Small Service Value(psig)

F )oOutdoor Ambient Temperature(

16 SEER R410A AC Charge Chart 5 TON

426402378355331310288266246105428404380357333311289268248109431407382358334312290269250113433409384360335313291271252117435411386361336314292272253121438413388363338316294274255125440415390365340318296276257129443418392367342320298278259133446419393369344322300279260137448421395371346324302281262141450423397373348326304283264145451424398374350328306285266149453426400377353331308287267153455428401379356334311289269157457430403381358336314292271161458431404383361339317294273165

10510095908580757065

no crankcase heater is used. heat is used or five (5) minutes ifmust be checked and unit powered for one (1) hour if

crank case 4) The unit electrical installation

Installation must be complete with brazed joints and drier visually inspected.F.

3)°F to 100°

F. 2) Indoor temperature between 70

°65

conditions must be met:

1) Outdoor temperature above

In order to properly charge the system the following

Leave bottle closed until ready to charge Manual Charge Hookup

has been evacuated, add the total calculated charge.new system Installation. if the entire systemWith an accurate scale (+/- 1 oz.) adjust charge difference between that shown on the unit data plate and that calculated for the

1.2 oz. per foot±” .6 oz. per foot 1/2±” 3/8 .4 oz. per foot±” .2 oz. per foot 5/16±” 1/4

15 ft add the charge as indicated below:unit is sufficient for 15 feet of standard size interconnecting liquid line. For tube lengths over

otherwise, evacuate the entire system. The factory refrigerant charge in the outdoorFor a new installation, evacuation of interconnecting tubing and indoor coil is adequate;CHARGING BY WEIGHT

valves.PRESSURE changes, go back to step 2

otherwise remove test equipment and cover therecover charge to lower it. 6. After running unit for 10 minutes if the SUCTION LINE

PRESSURE to the TARGET LIQUID PRESSURE, add charge to raise the pressure or rows and columns. 5. Compare the measured LIQUID LINE

LINE PRESSURE falls between rows or columns then estimate the TARGET LIQUID PRESSURE between the or SUCTION PRESSURE and the OUTDOOR AMBIENT TEMPERATURE, if falls between rows or columns then estimate the TARGET LIQUID PRESSURE

PRESSURE. 4. Find the TARGET LIQUID PRESSURE at the intersection between the SUCTION LINE AMBIENT TEMPERATURE within 6 inches of coil.

3. Measure SUCTION LINEFollow these steps: 1. Run in cooling mode at least 10 minutes. 2. Measure OUTDOORCHARGING BY LIQUID PRESSURE

THIS SYSTEM MUST NOT BE CHARGED BY SUBCOOLING.THIS IS A CHARGING PROCEDURE TO PREVENT OVERCHARGING.

REFRIGERANT CHARGING CHART

Page 3: Trane Submittal - 3 Split System Heat Pump Model 1 …...Scroll Compressor Condenser Coil Optional accessories Liquid line drier — The J4AC60 is fully charged from the factory. This

Literature Order Numbe r SS-PRC007-EN

File Numbe r —

Supersede s SS-PRC007-EN 2/0 2

Stocking Locatio n PI Louisville & Webb/Mason Houston

has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.

MechanicalSpecification Options

General

Casing

Refrigerant Controls

Scroll Compressor

Condenser Coil

Optional accessories

Liquid line drier

The J4AC60 is fully charged from the factory. This unit is designed to operateat outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with air handlers and furnace coils that are AHRI certified. The unit is certified to ETL. Exterior is designed for outdoor application.

Unit casing is constructed of heavy gauge, Galvanized steel and painted with a weather-resistant powder paint on all grilles, panels, pre-paint on all other panels. And had 500-hours salt spray tested.

Refrigeration system controls include condenserfan, compressor contactor.

Features include low vibration and noise.

The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by grille panels.

It is used to filter out impurities and water in the system, ensures system clean and dry.

OXBOX