Trane Submittal - 3 Split System Heat Pump Model 1 Phase … · 2020. 7. 10. · 2.0 Ton Split...
Transcript of Trane Submittal - 3 Split System Heat Pump Model 1 Phase … · 2020. 7. 10. · 2.0 Ton Split...
Product Specifications OUTDOOR UNIT
POWER CONNS. — V/PH/HZ MIN. BRCH. CIR. AMPACITY BR. CIR. PROT. RTG. - MAX. (AMPS)
COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZ R.L. AMPS - L.R. AMPS FACTORY INSTALLEDSTART COMPONENTS INSULATION/SOUND BLANKE TCOMPRESSOR HEAT
OUTDOOR FAN DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM @ 0.0 IN. W.G. NO. MOTORS - HP MOTOR SPEED R.P.M. VOLTS/PH/HZ F.L. AMPS
OUTDOOR COIL — TYPE ROWS - F.P.I. FACE AREA (SQ. FT.) TUBE SIZE (IN.) REFRIGERANT CONTROL
REFRIGERANT
LBS. — R-410 (O.D. UNIT) FACTORY SUPPLIED LINE SIZE - IN. O.D. GAS LINE SIZE - IN. O.D. LIQ.
CHARGING SPECIFICATION SUBCOOLING
DIMENSIONS CRATED (IN.) WEIGHT SHIPPING (LBS.) NET (LBS.)
J4AC4018A1000AA
TAG:
_________________________________
1.5 Ton Split SystemAir Conditioner - 1 Phase J4AC4018A1000AA
S UBMITTAL
J4AC4018A1000AA
208/230/1/6010.4
15SCROLL1 - 1
208/230/1/607.7 - 48.0
NOPROPELLER
17-3/4 - 1Axial - 1 16001 - 1/81075
208/230/1/600.70
PLATE FIN2 - 21 8.93/16
ORIFICE
5 LBS. - 2 OZ.YES3/43/8
8º FW X H X D
22-9/10x26-1/4x22-9/10
128121
NONO
J4AC4018A1000AA
Model H W L LIQUID VALVE SIZE GAS VALVE SIZE
633 (24-15/16) 554 (21-7/8) 3/8 3/4
NOTE: All dimensions are in mm/inches.
554 (21-7/8)
SUCTION LINE CONNECTION
CONTROL WIRING 7/8” (22.2mm)
KNOCKOUT 1-11/32” (34.5mm)
LIQUID LINE CONNECTION
SERVICE FITTING
SERVICE FITTING
POWER WIRING SEE DETAIL A
DETAIL A
HOLE 1-3/32” (27.8mm)
NOTE: GRILL APPEARANCE MAY VARY.
SERVICE ACCESS ALLOW 24” CLEARANCE
AIR INLETS LOUVERED PANELS ALLOW 12” MINIMUM CLEARANCE
W
ACCESS VALVLEFOR LOW PRESSURENOTE: ONLY ADOPTED BY HEAT PUMP, CAN BE USED FOR MEASURING PRESSURE AFTER SWITCHOVER VALVE-SUCTION TO COMPRESSOR ORREFRIGERANT CHARGE.
Product Specifications OUTDOOR UNIT
POWER CONNS. — V/PH/HZ MIN. BRCH. CIR. AMPACITY BR. CIR. PROT. RTG. - MAX. (AMPS)
COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZ R.L. AMPS - L.R. AMPS FACTORY INSTALLEDSTART COMPONENTS INSULATION/SOUND BLANKE TCOMPRESSOR HEAT
OUTDOOR FAN DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM @ 0.0 IN. W.G. NO. MOTORS - HP MOTOR SPEED R.P.M. VOLTS/PH/HZ F.L. AMPS
OUTDOOR COIL — TYPE ROWS - F.P.I. FACE AREA (SQ. FT.) TUBE SIZE (IN.) REFRIGERANT CONTROL
REFRIGERANT
LBS. — R-410 (O.D. UNIT) FACTORY SUPPLIED LINE SIZE - IN. O.D. GAS LINE SIZE - IN. O.D. LIQ.
CHARGING SPECIFICATION SUBCOOLING
DIMENSIONS CRATED (IN.) WEIGHT SHIPPING (LBS.) NET (LBS.)
J4AC4024A1000AA
TAG: _________________________________
2.0 Ton Split SystemAir Conditioner - 1 Phase J4AC4024A1000AA
S UBMITTAL
J4AC4024A1000AA
208/230/1/6013.4
20SCROLL1 - 1
208/230/1/6010.1 - 52
NOPROPELLER
18-7/8 - 1Axial - 1
18001 - 1/8 1075
208/230/1/600.7
PLATE FIN2 - 21103/16
ORIFICE
5 LBS. - 5 OZ.YES3/43/8
8º FW X H X D
24-7/10x26-1/4x24-7/10
139132
NONO
J4AC4024A1000AA
Model H W L LIQUID VALVE SIZE GAS VALVE SIZE
633 (24-15/16) 600 (23-5/8) 3/8 3/4
NOTE: All dimensions are in mm/inches.
600 (23-5/8)
SUCTION LINE CONNECTION
CONTROL WIRING 7/8” (22.2mm)
KNOCKOUT 1-11/32” (34.5mm)
LIQUID LINE CONNECTION
SERVICE FITTING
SERVICE FITTING
POWER WIRING SEE DETAIL A
DETAIL A
HOLE 1-3/32” (27.8mm)
NOTE: GRILL APPEARANCE MAY VARY.
SERVICE ACCESS ALLOW 24” CLEARANCE
AIR INLETS LOUVERED PANELS ALLOW 12” MINIMUM CLEARANCE
W
ACCESS VALVLEFOR LOW PRESSURENOTE: ONLY ADOPTED BY HEAT PUMP, CAN BE USED FOR MEASURING PRESSURE AFTER SWITCHOVER VALVE-SUCTION TO COMPRESSOR ORREFRIGERANT CHARGE.
Product Specifications OUTDOOR UNIT
POWER CONNS. — V/PH/HZ MIN. BRCH. CIR. AMPACITY BR. CIR. PROT. RTG. - MAX. (AMPS)
COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZ R.L. AMPS - L.R. AMPS FACTORY INSTALLEDSTART COMPONENTS INSULATION/SOUND BLANKE TCOMPRESSOR HEAT
OUTDOOR FAN DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM @ 0.0 IN. W.G. NO. MOTORS - HP MOTOR SPEED R.P.M. VOLTS/PH/HZ F.L. AMPS
OUTDOOR COIL — TYPE ROWS - F.P.I. FACE AREA (SQ. FT.) TUBE SIZE (IN.) REFRIGERANT CONTROL
REFRIGERANT
LBS. — R-410 (O.D. UNIT) FACTORY SUPPLIED LINE SIZE - IN. O.D. GAS LINE SIZE - IN. O.D. LIQ.
CHARGING SPECIFICATION SUBCOOLING
DIMENSIONS CRATED (IN.) WEIGHT SHIPPING (LBS.) NET (LBS.)
J4AC4030A1000AA
TAG:
_________________________________
2.5 Ton Split SystemAir Conditioner - 1 Phase
S UBMITTAL
J4AC4030A1000AA
208/230/1/6014.7
25SCROLL1 - 1
208/230/1/6010.9 - 63
NOPROPELLER
23 - 1Axial - 1
26501 - 1/6 825
208/230/1/601.0
PLATE FIN2 - 21133/16
ORIFICE
5 LBS. - 12OZ.YES3/43/8
8º FW X H X D29x26-1/4x29
157148
NONO
J4AC4030A1000AA
Model H W L LIQUID VALVE SIZE GAS VALVE SIZE
633 (24-15/16) 710 (28) 3/8 3/4
NOTE: All dimensions are in mm/inches.
710 (28)
SUCTION LINE CONNECTION
CONTROL WIRING 7/8” (22.2mm)
KNOCKOUT 1-11/32” (34.5mm)
LIQUID LINE CONNECTION
SERVICE FITTING
SERVICE FITTING
POWER WIRING SEE DETAIL A
DETAIL A
HOLE 1-3/32” (27.8mm)
NOTE: GRILL APPEARANCE MAY VARY.
SERVICE ACCESS ALLOW 24” CLEARANCE
AIR INLETS LOUVERED PANELS ALLOW 12” MINIMUM CLEARANCE
W
ACCESS VALVLEFOR LOW PRESSURENOTE: ONLY ADOPTED BY HEAT PUMP, CAN BE USED FOR MEASURING PRESSURE AFTER SWITCHOVER VALVE-SUCTION TO COMPRESSOR ORREFRIGERANT CHARGE.
J4AC4030A1000AA
Product Specifications OUTDOOR UNIT
POWER CONNS. — V/PH/HZ MIN. BRCH. CIR. AMPACITY BR. CIR. PROT. RTG. - MAX. (AMPS)
COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZ R.L. AMPS - L.R. AMPS FACTORY INSTALLEDSTART COMPONENTS INSULATION/SOUND BLANKE TCOMPRESSOR HEAT
OUTDOOR FAN DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM @ 0.0 IN. W.G. NO. MOTORS - HP MOTOR SPEED R.P.M. VOLTS/PH/HZ F.L. AMPS
OUTDOOR COIL — TYPE ROWS - F.P.I. FACE AREA (SQ. FT.) TUBE SIZE (IN.) REFRIGERANT CONTROL
REFRIGERANT
LBS. — R-410 (O.D. UNIT) FACTORY SUPPLIED LINE SIZE - IN. O.D. GAS LINE SIZE - IN. O.D. LIQ.
CHARGING SPECIFICATION SUBCOOLING
DIMENSIONS CRATED (IN.) WEIGHT SHIPPING (LBS.) NET (LBS.)
J4AC4036A1000AA
TAG:
_________________________________
3.0 Ton Split SystemAir Conditioner - 1 Phase
S UBMITTAL
J4AC4036A1000AA
208/230/1/6019.4
30SCROLL1 - 1
208/230/1/6014.7 - 75
NOPROPELLER
23-5/8 - 1Axial - 1
27001 - 1/6 825
208/230/1/601.0
PLATE FIN1 - 21
143/16
ORIFICE
5 LBS. - 14OZ.YES3/43/8
8º FW X H X D
30-1/5x26-1/4x30-1/5
163154
NONO
J4AC4036A1000AA
Model H W L LIQUID VALVE SIZE GAS VALVE SIZE
633 (24-15/16) 740 (29-1/8) 3/8 3/4
NOTE: All dimensions are in mm/inches.
740 (29-1/8)
SUCTION LINE CONNECTION
CONTROL WIRING 7/8” (22.2mm)
KNOCKOUT 1-11/32” (34.5mm)
LIQUID LINE CONNECTION
SERVICE FITTING
SERVICE FITTING
POWER WIRING SEE DETAIL A
DETAIL A
HOLE 1-3/32” (27.8mm)
NOTE: GRILL APPEARANCE MAY VARY.
SERVICE ACCESS ALLOW 24” CLEARANCE
AIR INLETS LOUVERED PANELS ALLOW 12” MINIMUM CLEARANCE
W
ACCESS VALVLEFOR LOW PRESSURENOTE: ONLY ADOPTED BY HEAT PUMP, CAN BE USED FOR MEASURING PRESSURE AFTER SWITCHOVER VALVE-SUCTION TO COMPRESSOR ORREFRIGERANT CHARGE.
J4AC4036A1000AA
Product Specifications OUTDOOR UNIT
POWER CONNS. — V/PH/HZ MIN. BRCH. CIR. AMPACITY BR. CIR. PROT. RTG. - MAX. (AMPS)
COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZ R.L. AMPS - L.R. AMPS FACTORY INSTALLEDSTART COMPONENTS INSULATION/SOUND BLANKE TCOMPRESSOR HEAT
OUTDOOR FAN DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM @ 0.0 IN. W.G. NO. MOTORS - HP MOTOR SPEED R.P.M. VOLTS/PH/HZ F.L. AMPS
OUTDOOR COIL — TYPE ROWS - F.P.I. FACE AREA (SQ. FT.) TUBE SIZE (IN.) REFRIGERANT CONTROL
REFRIGERANT
LBS. — R-410 (O.D. UNIT) FACTORY SUPPLIED LINE SIZE - IN. O.D. GAS LINE SIZE - IN. O.D. LIQ.
CHARGING SPECIFICATION SUBCOOLING
DIMENSIONS CRATED (IN.) WEIGHT SHIPPING (LBS.) NET (LBS.)
J4AC4042A1000AA
TAG:
_________________________________
3.5 Ton Split SystemAir Conditioner - 1 Phase
S UBMITTAL
J4AC4042A1000AA
208/230/1/6021.6
35SCROLL1 - 1
208/230/1/6015.9 - 112.3
NOPROPELLER
23 - 1Axial - 1
37001 - 1/31075
208/230/1/601.70
PLATE FIN2 - 21
173/16
ORIFICE
7 LBS. - 16OZ.YES3/43/8
8º FW X H X D29x34-1/2x29
201190
NONO
J4AC4042A1000AA
Model H W L LIQUID VALVE SIZE GAS VALVE SIZE
843 (33-3/16) 710 (28) 3/8 3/4
NOTE: All dimensions are in mm/inches.
710 (28)
SUCTION LINE CONNECTION
CONTROL WIRING 7/8” (22.2mm)
KNOCKOUT 1-11/32” (34.5mm)
LIQUID LINE CONNECTION
SERVICE FITTING
SERVICE FITTING
POWER WIRING SEE DETAIL A
DETAIL A
HOLE 1-3/32” (27.8mm)
NOTE: GRILL APPEARANCE MAY VARY.
SERVICE ACCESS ALLOW 24” CLEARANCE
AIR INLETS LOUVERED PANELS ALLOW 12” MINIMUM CLEARANCE
W
ACCESS VALVLEFOR LOW PRESSURENOTE: ONLY ADOPTED BY HEAT PUMP, CAN BE USED FOR MEASURING PRESSURE AFTER SWITCHOVER VALVE-SUCTION TO COMPRESSOR ORREFRIGERANT CHARGE.
J4AC4042A1000AA
Product Specifications OUTDOOR UNIT
POWER CONNS. — V/PH/HZ MIN. BRCH. CIR. AMPACITY BR. CIR. PROT. RTG. - MAX. (AMPS)
COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZ R.L. AMPS - L.R. AMPS FACTORY INSTALLEDSTART COMPONENTS INSULATION/SOUND BLANKE TCOMPRESSOR HEAT
OUTDOOR FAN DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM @ 0.0 IN. W.G. NO. MOTORS - HP MOTOR SPEED R.P.M. VOLTS/PH/HZ F.L. AMPS
OUTDOOR COIL — TYPE ROWS - F.P.I. FACE AREA (SQ. FT.) TUBE SIZE (IN.) REFRIGERANT CONTROL
REFRIGERANT
LBS. — R-410 (O.D. UNIT) FACTORY SUPPLIED LINE SIZE - IN. O.D. GAS LINE SIZE - IN. O.D. LIQ.
CHARGING SPECIFICATION SUBCOOLING
DIMENSIONS CRATED (IN.) WEIGHT SHIPPING (LBS.) NET (LBS.)
J4AC4048A1000AA
TAG:
_________________________________
4.0 Ton Split SystemAir Conditioner - 1 Phase
S UBMITTAL
J4AC4048A1000AA
208/230/1/6024.6
40SCROLL1 - 1
208/230/1/6018.3 - 108
NOPROPELLER
23 - 1Axial - 1
37001 - 1/31075
208/230/1/601.70
PLATE FIN2 - 21173/16
ORIFICE
7 LBS. - 16OZ.YES7/83/8
8º FW X H X D29x34-1/2x29
201190
NONO
J4AC4048A1000AA
Model H W L LIQUID VALVE SIZE GAS VALVE SIZE
843 (33-3/16) 710 (28) 3/8 7/8
NOTE: All dimensions are in mm/inches.
710 (28)
SUCTION LINE CONNECTION
CONTROL WIRING 7/8” (22.2mm)
KNOCKOUT 1-11/32” (34.5mm)
LIQUID LINE CONNECTION
SERVICE FITTING
SERVICE FITTING
POWER WIRING SEE DETAIL A
DETAIL A
HOLE 1-3/32” (27.8mm)
NOTE: GRILL APPEARANCE MAY VARY.
SERVICE ACCESS ALLOW 24” CLEARANCE
AIR INLETS LOUVERED PANELS ALLOW 12” MINIMUM CLEARANCE
W
ACCESS VALVLEFOR LOW PRESSURENOTE: ONLY ADOPTED BY HEAT PUMP, CAN BE USED FOR MEASURING PRESSURE AFTER SWITCHOVER VALVE-SUCTION TO COMPRESSOR ORREFRIGERANT CHARGE.
J4AC4048A1000AA
P ro d u c t S p e c i f i c a t i o n s O U T D O O R U N I T P O W E R C O N N S . — V / P H / H Z M I N . B R C H . C I R . A M P A C I T Y B R . C I R . P R O T . R T G . - M A X . ( A M P S ) C O M P R E S S O R N O . U S E D - N O . S P E E D S V O L T S / P H / H Z R . L . A M P S - L . R . A M P S F A C T O R Y I N S T A L L E D S T A R T C O M P O N E N T S I N S U L A T I O N / S O U N D B L A N K E T C O M P R E S S O R H E A T O U T D O O R F A N D I A . ( I N . ) - N O . U S E D TY P E D R I V E - N O. S P E E D S C F M @ 0 . 0 I N . W . G . N O . M O T O R S - H P M O T O R S P E E D R . P . M . V O L T S / P H / H Z F . L . A M P S O U T D O O R C O I L — T Y P E R O W S - F . P . I . F A C E A R E A ( S Q . F T . ) T U B E S I Z E ( I N . ) R E F R I G E R A N T C O N T R O L R E F R I G E R A N T L B S . — R - 4 1 0 ( O . D . U N I T ) F A C T O R Y S U P P L I E D L I N E S I Z E - I N . O . D . G A S L I N E S I Z E - I N . O . D . L I Q . C H A R G I N G S P E C I F I C A T I O N S U B C O O L I N G D I M E N S I O N S C R A T E D ( I N . ) W E I G H T S H I P P I N G ( L B S . ) N E T ( L B S . )
J4AC4060A1000AA
TAG: ____________________________ _ _ _ _ _
5.0 T o n S p l i t S y s te m A i r Conditioner - 1 Phase
S U B M I T T A L
J4AC4060A1000AA
2 0 8 / 2 3 0 / 1 / 6 0 2845
S C R O L L 1 - 1
2 0 8 / 2 3 0 / 1 / 6 0 21 - 127.9
N O PROPELLER 23-5 / 8 - 1 D I R E C T - 1
1 - 1 / 3 107 5
2 0 8 / 2 3 0 / 1 / 6 0 1.70
PLATE FIN 3 - 2118.4 3/16
O R I F I C E
7 L B S . - 12O Z . Y E S 7 / 8 3 / 8
8 º F W X H X D
30-1 / 5 x 34-1 / 2x30-1 / 5
214203
N O N O
J4AC4060A1000AA
M o d e l H W L L I Q U I D V A L VE S I Z E GAS V A L VE S I Z E
84 3 (33-3/16) 740 (29-1 / 8 ) 3 / 8 7 / 8
NOTE: All dimensions are in mm/inches.
740 (29-1 / 8 )
SUCTION LINE CONNECTION
CONTRO L WIRING 7/8” (22.2mm)
KNOCKOU T 1- 1 1/32” (34.5mm)
LIQUID LINE CONNECTION
SE R VICE FITTING
SE R VICE FITTING
POWER WIRING SEE DE T AI L A
DE T AI L A
HOLE 1-3/32” (27.8mm)
NOTE: GRIL L APPEARANCE M A Y V A R Y .
SE R VICE ACCESS ALLOW 24” CLEARANCE
AIR INLETS LOUVERED P ANELS ALLOW 12” MINIMUM CLEARANCE
W
ACCESS V A L VLE FOR LOW PRESSURE NOTE: ON L Y ADOPTED B Y HE A T PUM P , CAN BE USED FOR MEASURING PRESSURE AFTER SWITCHOVER V A L VE-SUCTION T O COMPRESSOR OR REFRIGERAN T CHARGE.
3800
J4AC4060A1000AA