TRADITIONAL PANELS FOR SECTIONAL DOORS

2
TRADITIONAL PANELS FOR SECTIONAL DOORS Panels featured with traditional joint made to guarantee repeated opening/closing cycles and to enable good long-lasting resistance to extreme weather conditions. Doors made of TECSEDO® BASE panels, together with accessory kits of the most important worldwide suppliers, have been successfully tested according to EN 13241-1 standard, under the supervision and approval of SP, Technical Research Institute of Sweden. TECHNICAL SPECIFICATIONS (further details are available on the technical sheets of each version) • Panels available in 500 mm and 610 mm module • External structure: prepainted galvanized steel, or aluminium, on both sides • Coatings: 25 μm Polyester or Plastisol 200 μm (on request) • Panels with traditional joint • Panels thickness: 40 mm or 80 mm (nominal) • A PVC sealing tape is applied during the production phase to the panel nose • Insulation: high-density (40 kg/m3) self-extinguishing, HCFC-free, closed cells, polyurethane foam • Female side is fitted with sealing foam gasket providing air and water tightness (both Class 3, according to EN 13241-1) • Both sides are protected by adhesive polythene film (to be removed before installation) • 2 longitudinal steel reinforcements are placed at hinge position to guarantee secure fixation. CONDITIONS • Standard length: 13,500 mm (Max.) – Standard packages contain 18 panels • Packaging: panels are wrapped by extensive polythene and positioned on polystyrene slabs over analogue support blocks (polystyrene sheet can be applied on the upper panel on request). 40mm Female side gasket Polyurethane foam Internal metal sheet Protective film External metal sheet Male side tape 30 - 32 mm 30 - 32 mm 30 - 32 mm 30 - 32 mm 80mm 40 mm 80 mm FIXING DETAILS MAX TOLERANCES Reinforcement Reinforcement Reinforcement +1-2mm ± 5 mm ± 2 mm < 0.5% of the total width < 2 mm/m; max = 10mm ± 1 mm 2 mm max L < 300 mm; s ≤ 1% 300 < L < 1000; s = 3 mm max following EN 10147 and EN 10143 ECCS European convention recommendation of metal construction Part II “Good practise” ECCS European convention recommendation of metal construction Part I “Design” – point 2.5.3 following EN 10169 Thickness: Length: Width: Out Of Square: Bowing: Height of microgrooves: Skew of metal parameters: Flatness L=distance between the edges of measuring s = shifting aside The size of S to be taken every 1000 mm Metal sheets: Aesthetic requirements: Prepainting systems: Brillance: width : 500 mm & 610 mm width : 500 mm & 610 mm Female side gasket Polyurethane foam Internal metal sheet Protective film External metal sheet Male side tape TECSEDO reserves the right to make modifications or improvements to the products at any time and without prior notice, whenever they are necessary. TPT REV. 2 – DEC 2020

Transcript of TRADITIONAL PANELS FOR SECTIONAL DOORS

Page 1: TRADITIONAL PANELS FOR SECTIONAL DOORS

TRADITIONAL PANELS FOR SECTIONAL DOORSPanels featured with traditional joint made to guarantee repeated opening/closing cycles and to enable good long-lasting resistance to extreme weather conditions. Doors made of TECSEDO® BASE panels, together with accessory kits of the most important worldwide suppliers, have been successfully tested according to EN 13241-1 standard, under the supervision and approval of SP, Technical Research Institute of Sweden.

TECHNICAL SPECIFICATIONS (further details are available on the technical sheets of each version)• Panels available in 500 mm and 610 mm module• External structure: prepainted galvanized steel, or aluminium, on both sides• Coatings: 25 μm Polyester or Plastisol 200 μm (on request)• Panels with traditional joint• Panels thickness: 40 mm or 80 mm (nominal)• A PVC sealing tape is applied during the production phase to the panel nose• Insulation: high-density (40 kg/m3) self-extinguishing, HCFC-free, closed cells, polyurethane foam• Female side is fitted with sealing foam gasket providing air and water tightness (both Class 3, according to EN 13241-1)• Both sides are protected by adhesive polythene film (to be removed before installation)• 2 longitudinal steel reinforcements are placed at hinge position to guarantee secure fixation.

CONDITIONS • Standard length: 13,500 mm (Max.) – Standard packages contain 18 panels • Packaging: panels are wrapped by extensive polythene and positioned on polystyrene slabs over analogue support blocks (polystyrene sheet can be applied on the upper panel on request).

40mm

Female side gasket

Polyurethane foam

Internal metalsheet

Protective film External metal sheet

Male sidetape

30 - 32 mm30 - 32 mm

30 - 32 mm30 - 32 mm

80mm

40 mm

80 mm

FIXING DETAILS MAX TOLERANCES

Reinforcement

Reinforcement Reinforcement

+1-2mm ± 5 mm ± 2 mm

< 0.5% of the total width < 2 mm/m; max = 10mm

± 1 mm2 mm max

L < 300 mm; s ≤ 1%300 < L < 1000; s = 3 mm max

following EN 10147 and EN 10143 ECCS European convention recommendation of metal

construction Part II “Good practise”ECCS European convention recommendation of metal

construction Part I “Design” – point 2.5.3following EN 10169

Thickness:Length: Width: Out Of Square: Bowing: Height of microgrooves: Skew of metal parameters: Flatness L=distance between the edges of measuring s = shifting aside The size of S to be taken every 1000 mmMetal sheets: Aesthetic requirements:

Prepainting systems:

Brillance:

width : 500 mm & 610 mm

width : 500 mm & 610 mm

Female side gasket

Polyurethane foam

Internal metalsheet

Protective film External metal sheet

Male sidetape

TECSEDO reserves the right to make modifications or improvements to the products at any time and without prior notice, whenever they are necessary.TPT REV. 2 – DEC 2020

Page 2: TRADITIONAL PANELS FOR SECTIONAL DOORS

FINGERSAFE PANELS FOR SECTIONAL DOORSPanels featured with special pinch free joint which enables to protect fingers, and other objects, during door opening/closing phases according to EN 12604 standard.Doors made of TECSEDO® SAFE panels, together with accessory kits of the most important worldwide suppliers, have been successfully tested according to EN 13241-1 standard, under the supervision and approval of SP, Technical Research Institute of Sweden.

TECHNICAL SPECIFICATIONS (further details are available on the technical sheets of each version)• Panels available in modules of 500 mm and 610 mm • External structure: prepainted galvanized STEEL• Special pinch free joint which protects fingers, and other objects, during door opening/closing phases (EN 12604)• Panels thickness: 40 mm (nominal)• Insulation: high-density self-extinguishing, HCFC-free, closed cells, polyurethane foam• Coatings: 25 μm Polyester, Polyamide (only for thicker plates), 35 μm Polyester Multilayer, or 140 μm PVC Film• Female side is fitted with sealing foam gasket providing air and water tightness (Both Class 3 according to EN 13241-1; water tightness increased up to 110 PA)• Both sides are protected by adhesive polythene film (to be removed before installation)• 2 internal continuous longitudinal steel reinforcements are placed at hinge position to guarantee secure fixation.

CONDITIONS • Standard length: 13,500 mm (Max) – Standard packages contain 18 panels • Packaging: panels are wrapped by extensive polythene and positioned on polystyrene slabs over analogue support blocks (polystyrene sheet can be applied on the upper panel on request).

Long nose (versions TSL, TSS, TSD)

Standard nose (all other versions)

30 - 32 mm

40 mm

40 mm

+1-2mm ± 5 mm ± 2 mm

< 0.5% of the total width < 2 mm/m; max = 10mm

± 1 mm2 mm max

L < 300 mm; s ≤ 1%300 < L < 1000; s = 3 mm max

following EN 10147 and EN 10143 ECCS European convention recommendation of metal

construction Part II “Good practise”ECCS European convention recommendation of metal

construction Part I “Design” – point 2.5.3following EN 10169

Thickness:Length: Width: Out Of Square: Bowing: Height of microgrooves: Skew of metal parameters: Flatness L=distance between the edges of measuring s = shifting aside The size of S to be taken every 1000 mmMetal sheets: Aesthetic requirements:

Prepainting systems:

Brillance:

FIXING DETAILS MAX TOLERANCES

Female side gasket

Polyurethane foam

Internal metalsheet

Protective film External metal sheet

ReinforcementReinforcement

Female side gasket

Polyurethane foam

Internal metalsheet

Protective film External metal sheet

ReinforcementReinforcement

width : 500 mm & 610 mm

width : 500 mm & 610 mm

StandardNose

LongNose

TECSEDO reserves the right to make modifications or improvements to the products at any time and without prior notice, whenever they are necessary.TPT REV. 2 – DEC 2020

Male side tape

30 - 32 mm

30 - 32 mm

Male side tape

30 - 32 mm