Wellspring Cancer Center
Physics Quality Assurance
Tomotherapy
![Page 2: Tomo Qa](https://reader034.fdocuments.net/reader034/viewer/2022051312/546b1566af795902048b4d30/html5/thumbnails/2.jpg)
TomoTherapy Hi-Art System
![Page 3: Tomo Qa](https://reader034.fdocuments.net/reader034/viewer/2022051312/546b1566af795902048b4d30/html5/thumbnails/3.jpg)
Photo of Tomotherapy Unit with covers removed
![Page 4: Tomo Qa](https://reader034.fdocuments.net/reader034/viewer/2022051312/546b1566af795902048b4d30/html5/thumbnails/4.jpg)
![Page 5: Tomo Qa](https://reader034.fdocuments.net/reader034/viewer/2022051312/546b1566af795902048b4d30/html5/thumbnails/5.jpg)
TomoTherapy Technical ProcessFrom Prescription to Treatment
• CT imaging scan• Treatment planning
– Contour target volumes (PTV) and organs at risk (OAR)
– Specify constraints on PTVs and OARs
– Inverse planning on computer which determines beam shape and intensity modulation every 7 degrees of rotation
– Reviewed and revised (if necessary) by physician
– Final approval by physician
• Delivery quality assurance (DQA) by medical physicist– Verifies that absolute dose delivered agrees with treatment plan
– Verifies that isodose distribution in a plane agrees with treatment plan
![Page 6: Tomo Qa](https://reader034.fdocuments.net/reader034/viewer/2022051312/546b1566af795902048b4d30/html5/thumbnails/6.jpg)
TomoTherapy Physics Quality Assurance
To verify the entire process of planning and performing treatments, two phantoms were obtained from the Radiological Physics Center at MD Anderson in Houston, TX
Pelvic / Prostate Phantom
Head & Neck Phantom
![Page 7: Tomo Qa](https://reader034.fdocuments.net/reader034/viewer/2022051312/546b1566af795902048b4d30/html5/thumbnails/7.jpg)
Prostate Treatment QAInstructions for irradiation of RPC pelvic/prostate phantom
Cross section view of Pelvic/prostate phantom
![Page 8: Tomo Qa](https://reader034.fdocuments.net/reader034/viewer/2022051312/546b1566af795902048b4d30/html5/thumbnails/8.jpg)
Dose instructions for pelvic/prostate phantom
![Page 9: Tomo Qa](https://reader034.fdocuments.net/reader034/viewer/2022051312/546b1566af795902048b4d30/html5/thumbnails/9.jpg)
![Page 10: Tomo Qa](https://reader034.fdocuments.net/reader034/viewer/2022051312/546b1566af795902048b4d30/html5/thumbnails/10.jpg)
Tomotherapy Quality Assurance• Daily Checks (performed by Radiation
Therapist, checked by Physicist)• Delivery Quality Assurance (DQA) on each
patient plan (Physicist)• Monthly Checks (Physicist)• Annual Calibration (Physicist)• Preventative Maintenance and Inspection
(PMI), Weekly Checks (Factory Service Engineer)
![Page 11: Tomo Qa](https://reader034.fdocuments.net/reader034/viewer/2022051312/546b1566af795902048b4d30/html5/thumbnails/11.jpg)
This device is used each day to check the calibration, energy, and beam profile. If any of these parameters fall outside of limits
set by the physicist, the reason must be determined and corrected before patient treatments can be performed.
Standard Imaging BeamChecker Plus
![Page 12: Tomo Qa](https://reader034.fdocuments.net/reader034/viewer/2022051312/546b1566af795902048b4d30/html5/thumbnails/12.jpg)
This photo shows the BeamChecker Plus in position for measurement of the radiation beam.
It is also used to verify the accuracy of the lasers used for patient positioning
![Page 13: Tomo Qa](https://reader034.fdocuments.net/reader034/viewer/2022051312/546b1566af795902048b4d30/html5/thumbnails/13.jpg)
Results of Daily QA Measurements on Tomotherapy using
Standard Imaging Beam Checker Plus
![Page 14: Tomo Qa](https://reader034.fdocuments.net/reader034/viewer/2022051312/546b1566af795902048b4d30/html5/thumbnails/14.jpg)
This equipment is used on a monthly basis to check the calibration and verify the energy of the
radiation beam.
![Page 15: Tomo Qa](https://reader034.fdocuments.net/reader034/viewer/2022051312/546b1566af795902048b4d30/html5/thumbnails/15.jpg)
This equipment is one method used to check the accuracy of each patient treatment plan