TOF0 and TOF1 time calibration

20
Y. Karadzhov, MICE CM25 Slide 1 TOF0 and TOF1 time calibration Yordan Karadzhov

description

TOF0 and TOF1 time calibration. Yordan Karadzhov. Absolute Time Calibration Method. General d escription of the TOF DAQ setup - PowerPoint PPT Presentation

Transcript of TOF0 and TOF1 time calibration

Page 1: TOF0 and TOF1  time calibration

Y. Karadzhov, MICE CM25

Slide 1

TOF0 and TOF1 time calibration

Yordan Karadzhov

Page 2: TOF0 and TOF1  time calibration

Y. Karadzhov, MICE CM25

Slide 2

Absolute Time Calibration Method

• General description of the TOF DAQ setup • The transit time of a signal through the PMT and the delays

introduced by the cable bringing it to the control room and by the discriminating electronics for a given channel is not known and it has to be measured.

• The digital value recorded by the TDCs corresponds to the absolute time since the latest reset of each TDC board.

• The board clocks are not synchronized, but the first channel (Ch1) of each board receive a copy of the Particle Trigger Request signal and this signal is used as a reference for all the PMTs of the TOF stations.

• Recorded TDC value can only make sense if referred to the Particle Trigger Request time.

• Which PMT (channel) delivers the trigger depends on the position on the hit; therefore the delay of the Particle Trigger Request signal depends on the position of the hit as well.

#)Detailed description of the method is available in MICE Note :http://mice.iit.edu/micenotes/public/pdf/MICE0251/MICE0251.pdf

Page 3: TOF0 and TOF1  time calibration

Y. Karadzhov, MICE CM25

Slide 3

Absolute Time Calibration Method

Page 4: TOF0 and TOF1  time calibration

Y. Karadzhov, MICE CM25

Slide 4

Absolute Time Calibration Method

• Time of the signal of a given PMT measured by the TDC:PMT(TDC) time Time of the hit Distance between the

position of the hit and the PMT

Cable delay Speed of light in the scintillator• Particle Trigger Request signal time for a given

combination of slabs (pixel). We assume the signal is given always by one and the same PMT for a given pixel.

Trigger(TDC) time Combined cable delay and light travel time

cablehitTDCPMT dt

c

xtt

'

triggerhitTDCtrigger dttt

Page 5: TOF0 and TOF1  time calibration

Y. Karadzhov, MICE CM25

Slide 5

Absolute Time Calibration Method

• For a given combination of slabs (a pixel) we have

where the bracket means the average over all the particles hitting the pixel ij. We will call this constant t0i ij.

constdtdtc

xtt triggercableTDCtrigger

TDCPMT iji

Page 6: TOF0 and TOF1  time calibration

Y. Karadzhov, MICE CM25

Slide 6

Absolute Time Calibration Method

Average light travel time is the average time it takes of the light to travel between two pixels (e.g. ij and ik ). For a horizontal slab we have

Indexes S and N mean South and North PMT.• For a given slab in TOF0 we have 10 light travel times

Δtij→ik, i.e. 200 light travel times for TOF0.

2

)00()00( ikNi

ikSi

ijNi

ijSiikij

ikij

tttt

c

xxt

Page 7: TOF0 and TOF1  time calibration

Y. Karadzhov, MICE CM25

Slide 7

Absolute Time Calibration Method

Relative trigger delays. In a given slab the difference between the t0 constants is given by

Average light travel time Difference between the trigger delays in pixels ij and ik

• If we choose a given pixel i0j0 as a reference we can define a

new calibration constant - the relative trigger delay ΔT trigger jl

)(00ikij triggertriggerikijikij dtdtttt

Pixel 5Pixel 4

Pixel 6

Page 8: TOF0 and TOF1  time calibration

Y. Karadzhov, MICE CM25

Slide 8

Absolute Time Calibration Method

• Calibration constants for TOF0 :– 40 t0i ij constants (one per PMT/channel) for TOF0 : the

difference between the delay in channel i (delays in the slab material, PMT, cables, …) and the delay of the channel which delivers the trigger when pixel ij is hit.

– 100 Relative Trigger Delays Δ Ttr ij (one per pixel) for TOF0 : the difference between trigger delay (the delay in the channel which is delivering the trigger) from pixel ij and the trigger delay for a pixel used as a reference.

Page 9: TOF0 and TOF1  time calibration

Y. Karadzhov, MICE CM25

Slide 9

Absolute Time Calibration Method

For the station which is not the trigger source (TOF1) if the pixel lk inTOF0 is hit (gives the trigger) and the pixel mn in TOF1 is hit, for theSouth PMT of slab m in TOF1, if we select only positrons, we have

• We have 28 t0 constants for TOF1.

constTtttlklkm trigger

TDCtrigger

TDCPMTSm 0

No Trigger delay correction

Page 10: TOF0 and TOF1  time calibration

Y. Karadzhov, MICE CM25

Slide 10

Absolute Time Calibration Method

• Calibration constants for TOF1 and TOF2 :– 28 t0m constants (one per PMT/channel) for TOF1 : the delay

in channel m of TOF1.

– 40 additional t0k constants (one per PMT/channel) will be needed for TOF2.

Page 11: TOF0 and TOF1  time calibration

Y. Karadzhov, MICE CM25

Slide 11

TOF0 time resolution

Time difference between the vertical and horizontal slabs in the same station is used to measure the time measurement resolution after the calibration.

The resolution on the difference in the calibrated pixels of TOF0 is ~105 ps. This translates into ~ 52 ps precision of the averaged two-plane measurement.

Page 12: TOF0 and TOF1  time calibration

Y. Karadzhov, MICE CM25

Slide 12

TOF1 time resolution

Measured resolution for the calibrated pixels in TOF1 ~ 136 ps.

This translates into ~ 68 ps precision of the averaged measurement.

Page 13: TOF0 and TOF1  time calibration

Y. Karadzhov, MICE CM25

Slide 13

Time Walk Correction

• The reference time is given by a PMT in the other plane of the Station and thetime walk effect in the measurement of the reference time is suppressed by anoffline constraint on the ADC pulse height in the reference PMT.• Precision in our case is limited by statistics (events are concentrated ina small region).

• Leading edge discriminators introduce a dependence of themeasured time on the collected charge (time walk).• To obtain the time walk correction one measures the differencebetween the time measured by the PMT and a reference time. • The dependence of this time difference on the PMT pulse height isapproximated (see the formula) and used as a correction.

20max

2

0max

21max )()(

)(PADC

P

PADC

PPADCf

Page 14: TOF0 and TOF1  time calibration

Y. Karadzhov, MICE CM25

Slide 14

Bad slab

• Main fraction of the events are in a region where Time Walk effect is stronger.

Page 15: TOF0 and TOF1  time calibration

Y. Karadzhov, MICE CM25

Slide 15

Good slab

• Main fraction of the events are in a region where Time Walk effect is not so strong.

Page 16: TOF0 and TOF1  time calibration

Y. Karadzhov, MICE CM25

Slide 16

How reliable is the absolutetime calibration ?

• The resolution in a given pixel can be measured before the absolute time calibration

• The expected total resolution of the detector can be calculated by the formula , where σi is the resolution in pixel i, Ni is the number of events in pixel i and Ntot is the total number of event.

totii NNresol /2

Page 17: TOF0 and TOF1  time calibration

Y. Karadzhov, MICE CM25

Slide 17

TOF0 Predicted Resolution vs. Real

Resolution

• In TOF0 predicted Resolution is 51.2 ps and measured is 52.3 ps

Worst pixel

Best pixel

Page 18: TOF0 and TOF1  time calibration

Y. Karadzhov, MICE CM25

Slide 18

TOF1 Predicted Resolution vs. Real

Resolution

• In TOF0 predicted Resolution is 64.2 ps and measured is 68.1 ps

Worst pixel

Best pixel

Page 19: TOF0 and TOF1  time calibration

Y. Karadzhov, MICE CM25

Slide 19

Demonstration of the capabilities of the TOF system

Page 20: TOF0 and TOF1  time calibration

Y. Karadzhov, MICE CM25

Slide 20

Conclusions

• 300 MeV/c electron beam is the best candidate for the new calibration.

• TW correction is critical for the precision of the time measurement.

• Systematic errors in the calibration of TOF1 are not very well understood.