IESNA LM79-2008 TEST REPORT TÜV SÜD America, Inc. Photometric Testing and Evaluation in Accordance with LM79-2008 Report Prepared for: Telephone: 678-733-2473 Model Tested: HB-88W-50K-WB Model Description: HighBay Luminaire Jonathan Eppstein President RedBird LED, Inc. 1202 Gail Drive NE Atlanta, GA 30319 United States Total Number of Pages: 9 (including this page) Report Prepared by: Report Reviewed by: Manufacturer: RedBird LED Technical Report Number: 72141753-01-LM79 Report Issue Date: September 7, 2018 NRG_F_10.04 Confidential Report Cutty Carscallen Bryan Cubitt TÜV SÜD Project Engineer TÜV SÜD Operations Manager Page 1 of 9 TÜV SÜD America is accredited under the ISO/IEC 17025:2005 program Testing Certificates Electrical 2955.09 TÜV SÜD America, Inc. 5945 Cabot Parkway, Suite 100, Alpharetta, GA 30005 USA Telephone: 678-341-5900 www.tuv-sud-america.com NRG_F_10.04, Rev. 2, Effective: 2015-07-13

Transcript of TÜV SÜD America, Inc. COMPLETE 16,949...2011/07/18  · 350 400 450 500 550 600 650 700 750 800...

Page 1: TÜV SÜD America, Inc. COMPLETE 16,949...2011/07/18  · 350 400 450 500 550 600 650 700 750 800 850 Flux (W/nm) Wavelength (nm) 2000 K 3000 K 5000 K 10,000 K 20,000 K 1000 K TÜV

IESNA LM79-2008 TEST REPORT TÜV SÜD America, Inc.

Photometric Testing and Evaluation in Accordance with LM79-2008

Report Prepared for:

Telephone: 678-733-2473

Model Tested: HB-88W-50K-WB

Model Description: HighBay Luminaire

Jonathan EppsteinPresident

RedBird LED, Inc.1202 Gail Drive NE

Atlanta, GA 30319

United States

Total Number of Pages: 9 (including this page)

Report Prepared by: Report Reviewed by:

Manufacturer: RedBird LED

Technical Report Number: 72141753-01-LM79

Report Issue Date: September 7, 2018

NRG_F_10.04

Confidential Report

Cutty Carscallen Bryan Cubitt

TÜV SÜD Project Engineer TÜV SÜD Operations Manager

Page 1 of 9 TÜV SÜD America is accredited under the ISO/IEC 17025:2005 program

Testing Certificates Electrical 2955.09

TÜV SÜD America, Inc.5945 Cabot Parkway, Suite 100, Alpharetta, GA 30005 USATelephone: 678-341-5900 www.tuv-sud-america.com

NRG_F_10.04, Rev. 2, Effective: 2015-07-13

Page 2: TÜV SÜD America, Inc. COMPLETE 16,949...2011/07/18  · 350 400 450 500 550 600 650 700 750 800 850 Flux (W/nm) Wavelength (nm) 2000 K 3000 K 5000 K 10,000 K 20,000 K 1000 K TÜV

IESNA LM79-2008

TEST REPORT

Report# 72141753-01-LM79

September 7, 2018

Summary of Key Test Results

Model# HB-88W-50K-WB

Manufacturer RedBird LED

TÜV Sample# 3427-1

Date of Test August 17, 2018

Luminous Flux (Lumens)

Input Power (Watts)

Efficacy (Lumens/Watt)

Notes:

Tested in Aperture Down orientation

Driver Model#

Philips XI095C275V054DNF1

Parameter

Stabilization Time (Min)

In-Situ Temp Test**

Color Temperature (CCT K)

Color Rendering Index (CRI)

Beam Angle

Measured Result

16,949

90.24

188

5061

85.3

177.5° (V) / 105.3° (H)

60

40.0 °C / 44.5 °C (LED/Driver)

The above results are recorded / derived from measurements in accordance with LM79-08

**ISTMT in accordance with “Energy Star Program Requirements for Luminaires – Version 2.1”.

Page 2 of 9

NRG_F_10.04

Confidential Report

TÜV SÜD America is accredited under the ISO/IEC 17025:2005 program

Testing Certificates Electrical 2955.09

TÜV SÜD America, Inc.5945 Cabot Parkway, Suite 100, Alpharetta, GA 30005 USATelephone: 678-341-5900 www.tuv-sud-america.com

NRG_F_10.04, Rev. 2, Effective: 2015-07-13

Page 3: TÜV SÜD America, Inc. COMPLETE 16,949...2011/07/18  · 350 400 450 500 550 600 650 700 750 800 850 Flux (W/nm) Wavelength (nm) 2000 K 3000 K 5000 K 10,000 K 20,000 K 1000 K TÜV

IESNA LM79-2008

TEST REPORT

Report# 72141753-01-LM79

September 7, 2018

Page 3 of 9

NRG_F_10.04

Confidential Report

TABLE OF CONTENTS

TÜV SÜD America is accredited under the ISO/IEC 17025:2005 program

Testing Certificates Electrical 2955.09

TÜV SÜD America, Inc.5945 Cabot Parkway, Suite 100, Alpharetta, GA 30005 USATelephone: 678-341-5900 www.tuv-sud-america.com

Test Results: 4

Spectral Flux and Chromaticity Diagram: 5

Zonal Lumen Summary: 5

Illuminance Plots: 6

Candela Plots: 6

ISTMT Temperature Measurement: 7

Photometric Testing Information: 8

Equipment List: 9

NRG_F_10.04, Rev. 2, Effective: 2015-07-13

Page 4: TÜV SÜD America, Inc. COMPLETE 16,949...2011/07/18  · 350 400 450 500 550 600 650 700 750 800 850 Flux (W/nm) Wavelength (nm) 2000 K 3000 K 5000 K 10,000 K 20,000 K 1000 K TÜV

0° - 180°: 1.44 90° - 270°: 1.28

IESNA LM79-2008

TEST REPORT

Report# 72141753-01-LM79

September 7, 2018

Photometric Results (120V Only)HB-88W-50K-WB

Integrating Sphere

Total Luminous Flux (Lumens) 16,949

Luminous Efficacy (Lumens/Watt) 187.82

Test Results-

The following results were obtained after stabilization of the sample in accordance with the requirements set forth

in section 5.0 of IES LM79-2008. Stability is achieved when the variation of 3 readings of light output and electrical

power over a period of 30 minutes, taken 15 minutes apart, is less than 0.5%.

Total Radiant Flux (Watts) 52.8

Chromaticity (Chroma x / Chroma y) 0.3436 0.3541

Chromaticity (Chroma u / Chroma v) 0.2095 0.3238

Correlated Color Temperature (CCT K) 5061

Color Rendering Index (CRI-Ra) 85.3

R9 Value 6.1

Electrical ResultsHB-88W-50K-WB

Integrating Sphere (120V / 277V)

Input Power (Watts) 90.24 90.03

Chromaticity (Chroma u' / Chroma v') 0.2095 0.4857

Duv Value 0.00184

Power Factor 0.991 0.957

A-THD% (Current %) 9.28 12.64

Input Voltage (Volts AC) 120.15 277.01

Input Current (Amps) 0.862 0.380

Additional ParametersHB-88W-50K-WB

Integrating Sphere Goniophotometer

Stabilization Time (Light and Power) 60 Minutes 63 minutes

Input Frequency (Hz) 60.0 60.0

Ambient Temperature 24.5 °C 24.5 deg C

In-Situ Temp Test (LED TMP / Driver TMP) LED TMP 40.0 °C DRIVER TMP 44.5 °C

Test Geometry Configuration 4π Type C

Spectroradiometer Labsphere CDS1100 Gigahertz Optik P9801

Spacing Criteria

Page 4 of 9

NRG_F_10.04

Confidential Report

TÜV SÜD America is accredited under the ISO/IEC 17025:2005 program

Testing Certificates Electrical 2955.09

TÜV SÜD America, Inc.5945 Cabot Parkway, Suite 100, Alpharetta, GA 30005 USATelephone: 678-341-5900 www.tuv-sud-america.com

NRG_F_10.04, Rev. 2, Effective: 2015-07-13

Page 5: TÜV SÜD America, Inc. COMPLETE 16,949...2011/07/18  · 350 400 450 500 550 600 650 700 750 800 850 Flux (W/nm) Wavelength (nm) 2000 K 3000 K 5000 K 10,000 K 20,000 K 1000 K TÜV

λ(Peak): λ(Dom):

IESNA LM79-2008

TEST REPORT

Report# 72141753-01-LM79

September 7, 2018

Spectral Flux and Chromaticity Diagram

453.7 nm 569.9 nm Tristimulus Values: x/y = 0.3436 / 0.3541

The locations on the diagram of the tristimulus coordinates are

indicated by the black diamond.

Zonal Lumen Summary

Zone Lumens

Spectral response of the Radiant Flux

(350nm to 850nm)Chromaticity Diagram, CIE 1931, 2 Degree

0-90 16,728.490-180 220.8

0-60 9,979.160-90 6,749.3

NRG_F_10.04

Confidential Report

0-180 16,949.2

% Lamp \ Luminaire

58.9%39.8%98.7%1.3%

100.0%

Page 5 of 9 TÜV SÜD America is accredited under the ISO/IEC 17025:2005 program

Testing Certificates Electrical 2955.09

.000

.100

.200

.300

.400

.500

.600

350 400 450 500 550 600 650 700 750 800 850

Flu

x (W

/nm

)

Wavelength (nm)

2000 K

3000 K

5000 K

10,000 K

20,000 K

1000 K

TÜV SÜD America, Inc.5945 Cabot Parkway, Suite 100, Alpharetta, GA 30005 USATelephone: 678-341-5900 www.tuv-sud-america.com

NRG_F_10.04, Rev. 2, Effective: 2015-07-13

Page 6: TÜV SÜD America, Inc. COMPLETE 16,949...2011/07/18  · 350 400 450 500 550 600 650 700 750 800 850 Flux (W/nm) Wavelength (nm) 2000 K 3000 K 5000 K 10,000 K 20,000 K 1000 K TÜV

4,412.6

IESNA LM79-2008

TEST REPORT

Report# 72141753-01-LM79

September 7, 2018

The following images depict the illuminance characteristics of the luminaire:

BEAM Width Chart Location: "\scan data\Goni\images\ "

Filename: "Model Number"_rep_5.png

or

"Model Number" _"Sample Number"_rep_5.png

Example: SKMR1607DLED930FL_rep_5.png

or

SKMR1607DLED930FL_2006-1_rep_5.png

FIELD Width Chart Location: "\scan data\Goni\images\ "

Filename: "Model Number"_rep_55. or

"Model Number" _"Sample Number"_rep_55.

Example: SKMR1607DLED930FL_rep_55. or

SKMR1607DLED930FL_2006-1_rep_55.

Test Results - Illuminance Plots

Location: "\scan data\Goni\images\ "

Filename: "Model Number"_rep_3.png

or

"Model Number" _"Sample

Number"_rep_3.png

Example:

SKMR1607DLED930FL_rep_3.png

or

SKMR1607DLED930FL_2006-

1_rep_3.png

Location: "\scan data\Goni\images\ "

Filename: "Model Number"_rep_1.png

or

"Model Number" _"Sample

Number"_rep_1.png

Example:

SKMR1607DLED930FL_rep_1.png

or

SKMR1607DLED930FL_2006-

1_rep_1.png

ISOfootcandle Plot ISOCandela Plot Polar Candela

Test Results - Candela Plots

The following images depict the luminous intensity distribution characteristics of the luminaire:

Page 6 of 9

NRG_F_10.04

Confidential Report

Maximum Candela = at Horizontal: 0.0°, Vertical: 7.5°

TÜV SÜD America is accredited under the ISO/IEC 17025:2005 program

Testing Certificates Electrical 2955.09

TÜV SÜD America, Inc.5945 Cabot Parkway, Suite 100, Alpharetta, GA 30005 USATelephone: 678-341-5900 www.tuv-sud-america.com

NRG_F_10.04, Rev. 2, Effective: 2015-07-13

Page 7: TÜV SÜD America, Inc. COMPLETE 16,949...2011/07/18  · 350 400 450 500 550 600 650 700 750 800 850 Flux (W/nm) Wavelength (nm) 2000 K 3000 K 5000 K 10,000 K 20,000 K 1000 K TÜV

All temperatures are normalized to 25°C ambient.

All temperatures are normalized to 25°C ambient.

IESNA LM79-2008

TEST REPORT

Report# 72141753-01-LM79

September 7, 2018

ISTMT temperature measurement at thermal stabilization (8 hours continuous operation).

Thermocouple locations (shown below) are in accordance with manufacturers recommended / stated

guidelines for TMP - Temperature Measurement Point.

"LED" Thermocouple Location at Tc

ISTMT Temperature Measurement

Tc location based upon hottest LED located adjacent to the LED Driver (mounted on the rear of the fixture).

"Driver" Thermocouple Location at Tc Sample Overview (DRIVERTMP Location)

Driver Test Results for RedBird LED : HB-88W-50K-WB

DVRTMP Temperature 44.5°C

LED Test Results for RedBird LED : HB-88W-50K-WB

LEDTMP Temperature 40.0°C

“DRIVER” Thermocouple location at TC

Location: "\05_System_Photo\ "

Filename: "Sample Number" -TC-D.jpg

Example: 2066-1-TC-D.jpg

Sample Overview (DRIVERTMP Location)

Location: "\05_System_Photo\ "

Filename: "Sample Number" -TCL-D.jpg

Example: 2066-1-TCL-D.jpg

Page 7 of 9

NRG_F_10.04

Confidential Report

TÜV SÜD America is accredited under the ISO/IEC 17025:2005 program

Testing Certificates Electrical 2955.09

TÜV SÜD America, Inc.5945 Cabot Parkway, Suite 100, Alpharetta, GA 30005 USATelephone: 678-341-5900 www.tuv-sud-america.com

NRG_F_10.04, Rev. 2, Effective: 2015-07-13

Page 8: TÜV SÜD America, Inc. COMPLETE 16,949...2011/07/18  · 350 400 450 500 550 600 650 700 750 800 850 Flux (W/nm) Wavelength (nm) 2000 K 3000 K 5000 K 10,000 K 20,000 K 1000 K TÜV

TÜV SÜD Photometric Testing Information

IESNA LM79-2008

TEST REPORT

Report# 72141753-01-LM79

September 7, 2018

The integrating spheres used for measurement utilize a “4π geometry” configuration in accordance with section 9 of

IES LM-79-2008 and is applicable for all types of SSL products (directional and non-directional light projections). The

spectroradiometer is an array-type detector manufactured and calibrated by Labsphere (Model# CDS1100).

Self-Absorption Correction

Testing is performed in accordance with the procedures outlined in IESNA LM79-2008. The sample is evaluated for

photometric and electrical characteristics using an integrating sphere and a goniophotometer, located in an

accredited, temperature and humidity-controlled, draft free photometric laboratory.

Sphere Geometry

The sample (UUT) is placed inside the integrating sphere and powered by a regulated and conditioned alternating or

direct current supply. The stabilization times shown on the results pages of this report denote the time of the 3rd

measurement (of the 3 consecutive readings) since this is the minimum time that the sample is assumed to have

taken to reach stabilization in accordance with section 5.0 of LM79-2008.

Sphere Calibration

The integrating sphere uses self-absorption correction to eliminate errors due to mismatches between the standard

reference lamp and the test samples being measured. This auxiliary correction lamp is a halogen type lamp powered

by a calibrated Lamp Power Supply manufactured and calibrated by Labsphere (model LPS150). Ambient

temperature is measured using a thermocouple located inside the integrating sphere at the same height as the

sample under test (UUT) and not more than 1 meter in horizontal distance away from the sample (section 2.2 of

LM79-2008). The thermocouple is located behind a baffle in order to eliminate any direct optical radiation from the

sample under test.

Sample Stabilization

Wattage = 75 Watts

Calibration Current = 2.679 Amperes

Luminous Flux = 1685 Lumens

Calibration Date = 2/17/2011 Labsphere - NIST traceable

Continued………………………..

Page 8 of 9

The integrating sphere is calibrated using a quartzline halogen lamp with the following specifications:

Manufacturer: EYE Lighting International

Model # J94/JD28V75W

Voltage = 28 Volts DC

NRG_F_10.04

Confidential Report

TÜV SÜD America is accredited under the ISO/IEC 17025:2005 program

Testing Certificates Electrical 2955.09

TÜV SÜD America, Inc.5945 Cabot Parkway, Suite 100, Alpharetta, GA 30005 USATelephone: 678-341-5900 www.tuv-sud-america.com

NRG_F_10.04, Rev. 2, Effective: 2015-07-13

Page 9: TÜV SÜD America, Inc. COMPLETE 16,949...2011/07/18  · 350 400 450 500 550 600 650 700 750 800 850 Flux (W/nm) Wavelength (nm) 2000 K 3000 K 5000 K 10,000 K 20,000 K 1000 K TÜV

TÜV SÜD Photometric Testing Information (continued)

IESNA LM79-2008

TEST REPORT

Report# 72141753-01-LM79

September 7, 2018

The Goniophotometer is a Mirror based Type C optical measurement system in accordance with section 9.3.1 of

IESNA LM79-2008.

Goniophotometer Calibration

Goniophotometer

Part Number: CSB-110

Lamp Number: 112-A

Voltage = 16.52 Volts DC

Wattage = 150 Watts

Calibration Current = 4.816 Amperes

Luminous Intensity = 151.5 Candelas

The Goniophotometer is calibrated using a frosted tungsten filament FDS/DZE lamp with the following

specifications:

Manufacturer: General Electric

TÜV SÜD Sphere System – contains the following:

Description Manufacturer / Model# TÜV SÜD Ref# Calibration Due Date

Calibration Date = 2/13/2011 (NIST Traceable)

TÜV SÜD Test Equipment List:

Power Analyzer Yokogawa WT210 ATLE0032 12/12/18

Power Source Chroma 61602 AC009 N/A

Integrating Sphere Labsphere LM760 SPH004 weekly

Spectroradiometer Labsphere CDS1100 ATLE0094 09/27/18

Goniophotometer M.E. GONC02 GON002 weekly

Spectroradiometer Gigahertz Optik P9801 GIG002 weekly

TÜV SÜD Mirror Goniophotometer System – contains the followingDescription Manufacturer / Model# TÜV SÜD Ref# Calibration Due Date

TÜV SÜD ISTMT Testing– contains the followingDescription Manufacturer / Model# TÜV SÜD Ref# Calibration Due Date

Power Analyzer Yokogawa WT210 ATLE0057 03/27/19

Power Source Chroma 61602 AC007 N/A

This technical report may only be quoted in full. Any use for advertising purposes must be granted in writing. 

This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production.

This report must not be used by the client to claim product certification, approval, or endorsement by A2LA, NIST, or any agency of the Federal Government

Page 9 of 9

NRG_F_10.04

Confidential Report

Thermometer Fluke 52-II ATLE0118 2/27/2019

TÜV SÜD America is accredited under the ISO/IEC 17025:2005 program

Testing Certificates Electrical 2955.09

TÜV SÜD America, Inc.5945 Cabot Parkway, Suite 100, Alpharetta, GA 30005 USATelephone: 678-341-5900 www.tuv-sud-america.com

NRG_F_10.04, Rev. 2, Effective: 2015-07-13