To, Date 22.03.2018
Member Secretary
Expert Appraisal Committee II
Infrastructure Development, Coastal Regulation Zone,
Building/Construction and Miscellaneous projects
Ministry of Environment, Forest and Climate Change
Indira Paryavaran Bhawan,
3rd Floor, Vayu Wing, Jor Bagh Road, Aliganj,
New Delhi-110 003.
Subject- Reply of queries raised towards Expansion of group housing at Khasra No. 1058m, 1726M/1,
1725M/2, 1724M, 1056M, 1058M, 1060/1 at Village Pasona Pargana, Loni, District-Ghaziabad,
Uttar Pradesh by M/s Nipun Builders & Developers Pvt. Ltd, [F.No.21-130/2017-IA-III]
Dear Sir,
With reference to the above-referred subject and EAC Minutes of Meeting (MoM), dated November 30th
2017, our point-wise reply of the queries are as follows:-
S.No. Queries Reply
1 A certificate from the local body supplying
water, specifying the total annual water
availability with the local authority, the
quantity of water already committed, the
quantity of water allotted to the project under
consideration and the balance water available.
This should be specified separately for ground
water and surface water sources, ensuring that
there is no impact on other users.
Water and sewer permission is attached as
Annexure 1.
2
The Air Quality Index shall be calculated for
base level air quality.
The air Quality Index of the project site is
151.
3 A detailed report on compliance to ECBC
norms.
ECBC compliance report is attached as
Annexure 2.
4 A detailed traffic management and traffic
decongestion plan to ensure that the current
level of service of the roads within a 05 kms
radius of the project is maintained and
improved upon after the implementation of the
project. This plan should be based on
cumulative impact of all development and
increased habitation being carried out or
proposed to be carried out by the project or
other agencies in this 05 Kms radius of the site
in different scenarios of space and time and the
• Main road connecting to the project site
is 75 m.
• Separate entry exit will be provided
Internal road width is 6 m wide.
• Speed breakers proposed at the entry
exit gate, at the entry/exit ramps of
basements and at regular interval of the
internal road.
• Signage for speed limit restricted to 20
kmph will be displayed along the
internal roads.
-
traffic management plan shall be duly validated
and certified by the State Urban Development
department and the P.W.D. and shall also have
their consent to the implementation of
components of the plan which involve the
participation of these departments.
• One way internal traffic movement is
proposed.
• Parking norm as per local regulation
5 The permission of the CGWA for abstraction of
ground water and for basement/excavation
dewatering.
This is an vertical expansion project so
permission of CGWA for basement/
excavation dewatering is not required.
Without getting approval from CGWA,
Ground water will not be extracted at any
stage of the project.
6 A certificate of adequacy of available power
from the agency supplying power to the
project along with the load allowed for the
project.
Power assurance letter is attached as
Annexure 3.
7 A certificate from the competent authority for
discharging treated effluent/ untreated
effluents into the Public sewer/
disposal/drainage systems along with the final
disposal point.
The same is attached as Annexure 1.
8 A certificate from the competent authority
handling municipal solid wastes, indicating the
existing civic capacities of handling and their
adequacy to cater to the M.S.W. generated
from project.
Municipal solid waste will be handled by
Ghaziabad Development authority
We trust that you will find the above clarifications / replies in-line with your requirements and looking
forward to get the environmental clearance for the project at the earliest.
-
ENERGY CONSERVATION AND BUILDING CODE
Project : Nipun Saffron Valley, Group Housing Project
Location : Village – Pasonda, Pargana - Loni, District- Ghaziabad, U.P
Compliance: ECBC
Date: 02.03.2018
ATMOS SUSTAINABLE SOLUTIONS PVT.
LTD
ENERGY CONSERVATION AND
BUILDING CODE
-
Energy Simulation report has been compiled by Atmos Sustainable Solutions Pvt. Ltd. For located in
Gurgaon, India. The scope of the project is 3 Residential Buildings.
SOFTWARE SUMMARY
The Energy simulation report contains results of energy analysis of the Proposed Buildings, To establish the
building performance rating as per ECBC, energy modeling was carried out by using simulation software
called Trane TRACE 700.
The software is very well capable of simulating and analyzing on hourly basis.
This Simulation study shows that the project performs better as compared to the ECBC benchmark for
Energy Performance Index (Criteria 8). The proposed project shows 40.97% lower energy consumption than
ECBC benchmark EPI.
GRIHA COMPLIANCE
MANDATORY
- Compliance with Energy Conservation Building Code-2007 as per clause 14.1.1. (Mandatory)
- Compliance with thermal comfort conditions as per National Building Code-2005/ASHRAE 55 – 2010.
-Minimum 20% reduction below the benchmark for Energy Performance Index (EPI) as per ECBC. (2 Points)
APPRAISAL
As per ECBC Energy Performance Credit, Every 10% reduction in EPI of the building under a specified
category shall fetch additional 2 points to a maximum of 8 points (50% reductions in EPI from the
benchmark). (2-10 points)
EXECUTIVE SUMMARY:
ATMOS SUSTAINABLE SOLUTIONS PVT.
LTD
ENERGY CONSERVATION AND
BUILDING CODE
-
EXECUTIVE SUMMARY:ECBC compliance (8 points)
Compliance with Energy Conservation Building Code-2007as per clause 14.1.1.
(6 Points) Compliance with thermal comfort conditions as per National Building
Code-2005/ASHRAE 55 – 2010. Reduction in 10% from benchmark for Energy
Performance Index (EPI) as per clause 14.1.5 (2 Points)
Credit points ( 2-8 Points)
Every 10% reduction in EPI of the building shall fetch an additional 2 points to a
maximum of 8 points.
As per Energy Performance Index, following are the points for Energy
Performance.
Percentage Energy Performance Index Points
10% reduction from benchmark (Mandatory) 2
20% reduction from benchmark 3
30% reduction from benchmark 5
40% reduction from benchmark 7
50% reduction from benchmark 10
ATMOS SUSTAINABLE SOLUTIONS PVT.
LTD
ENERGY CONSERVATION AND
BUILDING CODE
-
PROJECT INFORMATION: Project IOCL Residential Colony
Energy Simulation ECBC
Total Simulated Area 52656 sq.m.
Number of buildings and
designation5(Residential)
Type of building Residential
Climate Composite
Occupancy24 Hours occupancy for
Residential
ATMOS SUSTAINABLE SOLUTIONS PVT.
LTD
ENERGY CONSERVATION AND
BUILDING CODE
-
WEATHER:
ATMOS SUSTAINABLE SOLUTIONS PVT.
LTD
ENERGY CONSERVATION AND
BUILDING CODE
-
ASSUMPTIONS:
S. NO. MODEL
INPUT
PARAMETER
S
PROPOSED CASE
1. Exterior Wall
Construction200 mm AAC Block
(U-Value = 0.67 W/m²·°C)
2. Roof
Construction
150mm RCC slab with 120mm Brick Bat Coba
(U – Value = 1.65 W/m²·°C)
3. Glazing Glazing properties: Refer Material Glazing Sheet
description.
For Residential : U - factor: 3 W/m²·°C SHGC : 0.25
4. Shading devices Shading Devices - As per design
5. Wall Window
RatioTower 1 – 28%
Tower 1 – 30%
Tower 1 – 27%
6. Lighting Power
Density
[As per ECBC Standard]
Living Spaces: 7.5 w/sq.m.
Kitchen: 12.9 W/sq.m.
Toilet : 1.5 W/sq.m.
Corriodor : 4.32 W/sq.m. (20% Reduction in common
spaces)
Stairs : 5.2 W/sq.m. (20% Reduction in common spaces)
Parking : 1.76 W/sq.m. (20% Reduction in common
spaces)
ATMOS SUSTAINABLE SOLUTIONS PVT.
LTD
ENERGY CONSERVATION AND
BUILDING CODE
-
ASSUMPTIONS: S. NO. MODEL
INPUT
PARAMETER
S
PROPOSED CASE
7 Receptacle
Equip
Power Density
Bedroom : 1.2 w/sq.ft
Drawing Room: 2 w/sq.ft
Kitchen : 3 w/sq.ft
Study Room : 0.5 w/sq.ft
8. Occupancy
Sensors
None
9. Daylight
Sensors
None
10. HVAC System
TypeAir Cooled Unitary
Packaged Terminal Air Conditioner
11. Cooling
EquipmentCategory: PTAC
COP : 3.52
12. Coil Capacity Cooling Coil Capacity : 100
Heating Coil Capacity : 100
13. Heating
Equipment
Electric Resistance
14. Base Utility Type: Elevators
Hourly Consumption: 60.0 kW
15. Utility Rates 5.25 Rs/ kWH
ATMOS SUSTAINABLE SOLUTIONS PVT.
LTD
ENERGY CONSERVATION AND
BUILDING CODE
-
SIMULATION RESULTS : ENERGY CONSUMPTIONS
Towers Tower 1 Tower 2 Tower 3
Energy Type
Energy
10^3
kWh/yr
Energy
10^3
kWh/yr
Energy
10^3
kWh/yr
Lighting - ConditionedElectricity 48.68 37.86 6.94
Lighting - UnconditionedElectricity 64.96 50.53 9.26
Space HeatingElectricity 0.00 0.00 0.00
Space CoolingElectricity 228.73 177.91 32.59
Heat RejectionElectricity 15.70 12.21 2.24
Fans - ConditionedElectricity 33.32 25.92 4.75
Total Building Consumption (Q) Electricity391.39 304.43 55.77
Conditioned Area 4094.49 3407.09 987.14Non Conditioned Area
5004.37 4163.24 531.54
Total Area (A) in Sq. m. 9098.87 7571.33 1518.69
EPI (E1) in Kwh/sq.m./yr.= Q/A Q/A Q/A
= 57.8 111.11 111.11
ECBC Bench marked EPI 70 70 70
Proposed case reduction in energy consumption over benchmark consumption
35.81% 48.% 47.54
WEIGHTED AVARAGE IMPACTREDUCTION THROUGH THE PROJECT
40.97%
ATMOS SUSTAINABLE SOLUTIONS PVT.
LTD
ENERGY CONSERVATION AND
BUILDING CODE
-
CONCLUSIONS:
• Criteria 8
- 7 Points are being achieved in Criteria 8 due to achievement of benchmark
Energy Performance Index and EPI reduction of 40.97% over the base case.
Percentage Energy Performance Index Points
10% reduction from benchmark (Mandatory) 2
20% reduction from benchmark 3
30% reduction from benchmark 5
40% reduction from benchmark 7
50% reduction from benchmark 10
ATMOS SUSTAINABLE SOLUTIONS PVT.
LTD
ENERGY CONSERVATION AND
BUILDING CODE
-
1) ECM’S
2) Envelope Details
3) Sectional Details
4) Schedules
5) External Lighting Calculation
ANNEXURE:
ATMOS SUSTAINABLE SOLUTIONS PVT.
LTD
ENERGY CONSERVATION AND
BUILDING CODE
-
ENERGY CONSERVATIVE METHODS (ECM’S):
The proposed building achieves energy reduction by following
ECM’s
1. Efficient HVAC systems.
Residential Area – PTAC COP 3.5
2. Good envelope properties for wall, Roof and Glazing
Wall - 200 mm AAC Block (U-Value = 0.67 W/m²·°C)
Roof - 150mm RCC slab with 120mm Brick Bat
(U – Value = 0.58 W/m²·°C)
Glazing - U value for Residential = 1.6 W/m²·°C, VLT =
33%
3. Shading devices – As per Design.
4. Solar Cells – Solar panels of 12 KWp capacity.
ATMOS SUSTAINABLE SOLUTIONS PVT.
LTD
ENERGY CONSERVATION AND
BUILDING CODE
-
ENVELOPE DETAILS:
WALLS
ROOF
GLASS For Residential : U - factor: 3 W/m²·°C SHGC: 0.25
Autoclaved Aerated Concrete Blocks (AAC)
Material DescriptionThickness
(mm)Conductivity (w/m.c)
Resistance (m2.C/W)
Outside Surface Resist. 0.059
External Plaster (Cement plaster, sand
aggregate)16 0.72 0.027777778
AAC Block 200 0.17 1.212
Internal Plaster (Gypsum plaster, sand
aggregate)12 0.22 0.063636364
Inside Surface Resist. 0.121
R-Value 1.48U-Value 0.674
Roof
Material DescriptionThickness
(mm)Conductivity (w/m.c)
Resistance (m2.C/W)
Outside Surface Resist. 0.05864
China Mosaic 50 1.5996 0.031257814
20mm Mortar 20 0.72702 0.02750956
40mm Screed 40 0.72 0.055555556
40mm Screed 40 0.72 0.055555556
Brick Bat Coba 120 0.811 0.147965475
150mm RCC 150 1.4 0.107142857
Inside Surface Resist. 0.12063
R-Value 0.60U-Value 1.655
ENERGY CONSERVATION AND
BUILDING CODE
ATMOS SUSTAINABLE SOLUTIONS PVT.
LTD
-
SECTIONAL DETAILS:
Wall : 200 mm AAC Block (U-0.67 W/m²·°C)
ROOF : 150mm RCC Slab with 50mm PUF Roof (U-1.65
W/m²·°C)
ATMOS SUSTAINABLE SOLUTIONS PVT.
LTDENERGY CONSERVATION AND
BUILDING CODE
-
SCHEDULES: People
BEDROOM Timing percentage(%)
People
Midnight 07:00 AM 80
07:00 AM 10:00 PM 20
10:00 PM Midnight 70
LIVING ROOM Timing percentage(%)
People
Midnight 07:00 AM 0
07:00 AM 10:00 AM 30
10:00 AM 06:00 PM 50
06:00 PM 10:00 PM 30
10:00 PM Midnight 0
KITCHEN Timing percentage(%)
People
Midnight 07:00 AM 0
07:00 AM 09:00 AM 80
09:00 AM 01:00 PM 0
01:00 PM 02:00 PM 80
02:00 PM 07:00 PM 0
07:00 PM 09:00 PM 80
09:00 PM Midnight 0
CLUB HOUSE Timing percentage(%)
People
Midnight 06:00 AM 0
06:00 AM 09:00 AM 70
09:00 AM 05:00 PM 20
05:00 PM 08:00 PM 70
08:00 PM Midnight 0
Multipurpose Hall Timing percentage(%)
People
Midnight 06:00 PM 0
06:00 PM 10:00 PM 20
10:00 PM Midnight 10
Sports/Game Timing percentage(%)
People
Midnight 06:00 AM 0
06:00 AM 10:00 AM 30
10:00 AM 01:00 PM 0
01:00 PM 02:00 PM 30
02:00 PM 05:00 PM 0
05:00 PM 08:00 PM 30
08:00 PM Midnight 0
ATMOS SUSTAINABLE SOLUTIONS PVT.
LTDENERGY CONSERVATION AND
BUILDING CODE
-
SCHEDULES: Lighting BEDROOM Timing percentage(%)
LIGHTINGMidnight 06:00 PM 1006:00 PM Midnight 60
LIVING ROOM Timing percentage(%)
LIGHTINGMidnight 06:00 PM 1006:00 PM Midnight 60
KITCHEN Timing percentage(%)
LIGHTING
Midnight 07:00 AM 507:00 AM 09:00 AM 6009:00 AM 06:00 PM 006:00 PM 10:00 PM 8010:00 PM Midnight 5
PASSAGE/LOBBY Timing percentage(%)
LIGHTINGMidnight 06:00 AM 2006:00 AM 07:00 PM 006:00 PM Midnight 70
SURFACE PARKING Timing percentage(%)
LIGHTINGMidnight 07:00 AM 5007:00 AM 06:00 PM 006:00 PM Midnight 80
BASEMENT PARKING Timing percentage(%)
LIGHTINGMidnight 07:00 AM 6007:00 AM 06:00 PM 2006:00 PM Midnight 80
ATMOS SUSTAINABLE SOLUTIONS PVT.
LTDENERGY CONSERVATION AND
BUILDING CODE
-
SCHEDULES: Lighting
Multipurpose Hall Timing percentage(%)
LIGHTING
Midnight 06:00 PM 0
06:00 PM 10:00 PM 30
10:00 PM Midnight 20
Sports/Game Timing percentage(%)
LIGHTING
Midnight 06:00 AM 0
06:00 AM 10:00 AM 40
10:00 AM 01:00 PM 0
01:00 PM 02:00 PM 40
02:00 PM 05:00 PM 0
05:00 PM 08:00 PM 70
08:00 PM Midnight 0
ATMOS SUSTAINABLE SOLUTIONS PVT.
LTDENERGY CONSERVATION AND
BUILDING CODE
-
SCHEDULES: Miscellaneous / EquipmentsBEDROOM Timing percentage(%)
Misc. / Equipments
Midnight 07:00 AM 10
07:00 AM 10:00 AM 20
10:00 AM 06:00 PM 50
06:00 PM 10:00 PM 80
10:00 PM Midnight 20
LIVING ROOM Timing percentage(%)
Misc. / Equipments
Midnight 07:00 AM 0
07:00 AM 10:00 AM 20
10:00 AM 06:00 PM 50
06:00 PM 10:00 PM 70
10:00 PM Midnight 20
KITCHEN Timing percentage(%)
Misc. / Equipments
Midnight 07:00 AM 10
07:00 AM 09:00 AM 70
09:00 AM 01:00 PM 20
01:00 PM 02:00 PM 40
02:00 PM 07:00 PM 20
07:00 PM 09:00 PM 70
09:00 PM Midnight 10
CLUB HOUSE Timing percentage(%)
Misc. / Equipments
Midnight 06:00 AM 0
06:00 AM 09:00 AM 60
09:00 AM 05:00 PM 20
05:00 PM 08:00 PM 60
08:00 PM Midnight 10
ATMOS SUSTAINABLE SOLUTIONS PVT.
LTDENERGY CONSERVATION AND
BUILDING CODE