TM640 ALARMS, TRENDS AND DIAGNOSTICS. Alarm system Trend systemDiagnostics Summary Alarms, Trends...

Click here to load reader

download TM640 ALARMS, TRENDS AND DIAGNOSTICS. Alarm system Trend systemDiagnostics Summary Alarms, Trends and Diagnostics Diagnostics

of 37

  • date post

    22-Dec-2015
  • Category

    Documents

  • view

    226
  • download

    4

Embed Size (px)

Transcript of TM640 ALARMS, TRENDS AND DIAGNOSTICS. Alarm system Trend systemDiagnostics Summary Alarms, Trends...

  • Slide 1
  • TM640 ALARMS, TRENDS AND DIAGNOSTICS
  • Slide 2
  • Alarm system Trend systemDiagnostics Summary Alarms, Trends and Diagnostics Diagnostics
  • Slide 3
  • Various methods for assigning URLs
  • Slide 4
  • Linking the HTML control to a text group
  • Slide 5
  • Slide 6
  • Activating the System Diagnostics Manager
  • Slide 7
  • URLs for displaying the SDM Panel sizeHTMLView sizeURL QVGA316 x 191http://127.0.0.1/sdm-qvga/qvga.cgi VGA620 x 339http://127.0.0.1/sdm-vga/vga.cgi XGA1004 x 567http://127.0.0.1/sdm-xga/xga.cgi
  • Slide 8
  • Results
  • Slide 9
  • Alarm system Trend systemDiagnostics Summary Alarms, Trends and Diagnostics Trend system
  • Slide 10
  • Trend control components Trend curves Time axis Measurement cursor Axis labels Value axis Trend container
  • Slide 11
  • Creating the trend control
  • Slide 12
  • Trend Wizard Online trend Data point values are displayed over time value =20 4060
  • Slide 13
  • Setting the time range and sampling rate Duration Displayed time range In this example: Duration [s]: 90 => 01:30 min Sampling rate Sampling rate specifies the intervals at which the value is sampled and displayed
  • Slide 14
  • Setting the recording mode Single A specific duration is recorded Continuous Time axis is continuous Current trend values always displayed 02:60
  • Slide 15
  • Trend types User trend Values from an array are read and displayed trend_array = { 20, 40, 60 } 50 ms100 ms 150 ms
  • Slide 16
  • Displaying curves in the trend control Channels Specifies how many trend curves are displayed in the control
  • Slide 17
  • Linking trend curves with the logic Trend data For each trend curve assign a data point and color
  • Slide 18
  • Linking trend curves with the logic
  • Slide 19
  • Slide 20
  • Appearance Grid Grid and color settings Scales Color settings
  • Slide 21
  • Configuring the measurement cursor
  • Slide 22
  • Trend data properties
  • Slide 23
  • Slide 24
  • Trend components
  • Slide 25
  • Trend data assignments
  • Slide 26
  • Alarm system Trend systemDiagnostics Summary Alarms, Trends and Diagnostics Alarm system
  • Slide 27
  • Alarm configuration Display Alarm text Status messages Error states Acknowledgement Everything at a glance Clearly organized Bitmaps
  • Slide 28
  • Alarm groups
  • Slide 29
  • Message type - Acknowledgment requirements Messages Operating states Acknowledgment not required Non-critical Warnings Error states Acknowledgment preferred No action required Alarms Critical error states Acknowledgment required Action necessary
  • Slide 30
  • Linking the alarm group with the logic
  • Slide 31
  • Effect of the logic on the alarm system alarmCoffee [ 0 ] = 1 000000 012345 000001100000000100 24
  • Slide 32
  • Alarm control configuration
  • Slide 33
  • Alarm lists Current Active and inactive unacknowledged History Possible to set which event is recorded Configuration Alarms from all groups except group alarms Alarms can only be bypassed here Active Active unacknowledged alarms
  • Slide 34
  • Display configuration
  • Slide 35
  • Slide 36
  • Alarm map - Current A l a r m t e x t 1 Alarm list A l a r m t e x t 5 00000000 00000010 01000010 01000000 01234567
  • Slide 37
  • Alarm map - History A l a r m t e x t 1 T Alarm history A l a r m t e x t 5 T 00000000 00000010 01000010 01000000 01234567 A l a r m t e x t 1 R
  • Slide 38
  • Alarm system Trend systemDiagnostics Summary Alarms, Trends and Diagnostics Summary
  • Slide 39
  • ASIV ALARMS, TRENDS AND DIAGNOSTICS TM640 TM600 Introduction to Visualization TM610 Working with Integrated Visualization TM640 Alarm, Trends and Diagnostics TM670 Advanced Visual Components