Pro-Clean® stratified tanks with spherical exchanger con-nection for domestic hot water and heatingMulti-functional stratified tank system (only in combination with a spherical ex-changer) made of S 235 JR steel (stainless-steel DIN 1.4404/ approx. SAE 410) for domestic hot water and heating. Backup tank with optimum stratified charging without tank mixing with integrated hygienic water heating us-ing a continuous heating process with stainless-steel corrugated pipe and tapping devices. Inflow absorbers ensure optimum retention of stratification. Expandable with PS heating tank
Area of use• In solar systems, water heating and backup heating• In biomass systems as a backup tank• In heat pump systems as a tank for hot water and heating
Advantages• Optimum use of solar energy for hot water and heating• Simple functional concept without complex technology (intuitive use) • Long service life• Improved e�ciency for every heating system (solar, biomass, heat pump)• Hygienic fresh water heating using a special corrugated stainless-steel pipe• Space-saving design with minimum heat loss (polyester fibre fleece insulation)
Technical description
Max. backup operating pressure 3 bar
Max. operating pressure of domestic hot water 6 bar
Hot water connection 2 x 1" female thread* V4A (no. 1.4401)
Cold water connection 2 x 1" female thread* V4A (no. 1.4401)
Heating/boiler connection 1½" female thread* with inflow absorber
Thermometer and sensor connection 1/2" female thread/6 mm contact sensor sleeves
Max. temperature 110 °C
PRO-CLEAN® STRATIFIED TANKPRODUCT DESCRIPTION
SPECIFICATIONS
Specifications
TypeOverall
height with Insulation1
Ø with insulation1
Ø without insulation1
Width A with
insulation1
Width B with
insulation1
Tilt height1 Weight Item no.
PC 500 1860 mm 850 mm 650 mm 1020 mm 1175 mm 1820 mm 178 kg 1610805
PC 800 2010 mm 950 mm 750 mm 1105 mm 1280 mm 1975 mm 210 kg 1610806
PC 1000B 2050 mm 1050 mm 850 mm 1180 mm 1380 mm 2020 mm 240 kg 1610807
PC 1000S 2220 mm 990 mm 790 mm 1140 mm 1320 mm 2185 mm 235 kg 1610808
PC 1250 2300 mm 1100 mm 900 mm 1235 mm 1440 mm 2270 mm 276 kg 1610809
PC 1500 2290 mm 1200 mm 1000 mm 1320 mm 1540 mm 2280 mm 303 kg 1610810
PC 2000 2380 mm 1300 mm 1100 mm 1400 mm 1640 mm 2380 mm 360 kg 1610811
PC 2500 2270 mm 1500 mm 1300 mm 1600 mm 1840 mm 2350 mm 448 kg 1610812
PC 3000 2760 mm 1470 mm 1250 mm 1530 mm 1790 mm 2780 mm 458 kg 1610813
PC 4000 2390 mm 1820 mm 1600 mm 1830 mm 2130 mm 2520 mm 550 kg 1610814
PC 5000 2900 mm 1820 mm 1600 mm 1830 mm 2130 mm 3020 mm 630 kg 1610815
1) All size specifications have a tolerance range of +/- 3%
139
1) All size specifications have a tolerance range of +/- 3%
Pro-Clean® 2WR stratified tanks with spherical exchanger connection for domestic hot water and heatingMulti-functional stratified tank system (only in combination with a spherical ex-changer) made of S 235 JR steel (stainless-steel DIN 1.4404/ approx. SAE 410) for domestic hot water and heating. Backup tank with optimum stratified charging without tank mixing with integrated hygienic water heating using a continuous heating process with two stainless-steel corrugated pipes and tapping devices. Inflow absorbers ensure optimum retention of stratification. Expandable with PS heating tank.
Area of use• In solar systems, water heating and backup heating• In biomass systems as a backup tank• In heat pump systems as a tank for hot water and heating
Advantages• Optimum use of solar energy for hot water and heating• Simple functional concept without complex technology (intuitive use)• Long service life• Improved e�ciency for every heating system (solar, biomass, heat pump)• Hygienic fresh water heating using a special corrugated stainless-steel pipe• Space-saving design with minimum heat loss (polyester fibre fleece insulation)
Technical description
Max. backup operating pressure 3 bar
Max. operating pressure of domestic hot water 6 bar
Hot water connection 2 x 1" female thread* V4A (no. 1.4401)
Cold water connection 2 x 1" female thread* V4A (no. 1.4401)
Heating/boiler connection 1½" female thread* with inflow absorber
Thermometer and sensor connection 1/2" female thread/6 mm contact sensor sleeves
Max. temperature 110 °C
Specifications
TypeTotal height with insulation1
Ø withinsulation1
Ø withoutinsulation1
Width A with insulation1
Width B with insulation1 Tilt height1 Weight Item no.
PC2WR1250 2300 mm 1100 mm 900 mm 1235 mm 1440 mm 2270 mm 276 kg 1610816
PC2WR 1500 2290 mm 1200 mm 1000 mm 1320 mm 1540 mm 2280 mm 334 kg 1610817
PC2WR 2000 2380 mm 1300 mm 1100 mm 1400 mm 1640 mm 2380 mm 393 kg 1610818
PC2WR 2500 2270 mm 1500 mm 1300 mm 1600 mm 1840 mm 2350 mm 483 kg 1610819
PC2WR 3000 2760 mm 1470 mm 1250 mm 1530 mm 1790 mm 2780 mm 493 kg 1610820
PC2WR 4000 2390 mm 1820 mm 1600 mm 1830 mm 2130 mm 2520 mm 585 kg 1610821
PC2WR 5000 2900 mm 1820 mm 1600 mm 1830 mm 2130 mm 3020 mm 665 kg 1610822
PRODUCT DESCRIPTION
SPECIFICATIONS
PRO-CLEAN® STRATIFIED TANK 2WR
140
m2 n
g
hi
j
kl
e1
f
ab
cd
1
1
1
1 13b
12
10
9
8
7
64
2a
100
13a
2b
e2
m1
Insulation thickness of PC 3000, PC 4000 and PC 5000 is 110 mm.
Pro-Clean®
Tank
Volume at sleeveSleeve
no.Sleeve height
(measured from the lid)
Volume
4 H1 l16 H2 l27 H3 l38 H4 l49 H5 l5
10 H6 l612 H7 l713 H8 l8
Total volume
*
* only for PC 1000S
¾" Sleeve closed
Insulation
Domestic hot water connection
KmDomestic hot water connection
Insulation
Flan
ge
DIMENSIONS
PRO-CLEAN® STRATIFIED TANK + 2WR
Cross section
optional:Elec. heating ext. (10 cm)if elec. immersion heater used
spherical exch. flange
141
PositionUnit of
measurePC500
PC 800
PC 1000S
PC 1000B
PC 1250
(2WR)
PC 1500
(2WR)
PC 2000
(2WR)
PC 2500
(2WR)
PC 3000
(2WR)
PC 4000
(2WR)
PC 5000
(2WR)
a mm 1540 1540 1540 1540 1560 1600 1610 1660 2120 2010 2010b mm 1150 1150 1150 1150 1170 1210 1220 1270 1560 1450 1450c mm 720 720 720 720 740 780 790 840 1030 920 920d mm 290 290 290 290 310 350 360 410 400 290 290
e1 mm 260 280 280 295 305 340 355 410 395 465 465e2 (2WR) mm – – – – 405 440 455 510 495 565 565
f mm 340 370 380 380 380 425 450 495 475 540 610f (2WR) mm – – – – 480 560 575 630 615 685 685
g mm 640 660 710 720 730 720 790 800 930 840 1000h mm 830 920 1000 950 1010 980 1030 1010 1250 1100 1340i mm 940 1060 1160 1090 1180 1160 1210 1160 1450 1240 1520j mm 1050 1200 1300 1230 1350 1330 1400 1300 1640 1380 1710
k mm 1160 1340 1420 1340 1520 1510 1520 1420 1820 1520 1900l mm 1270 1450 1530 1450 1630 1620 1630 1530 1930 1630 2040
m1 (2WR) mm – – – – 1940 1905 1960 1820 2330 1880 2390m2 mm 1650 1780 1990 1790 2040 2005 2080 1920 2430 1980 2490
n mm 1760 1910 2120 1950 2200 2190 2280 2170 2660 2290 2800o1 mm 1540 1680 1900 1680 1700 1890 1950 1810 2200 1700 2300o2 mm – – 1680 – – – – – – – –p mm 1150 1170 1170 1170 1170 1280 1370 1360 1460 1170 1600q mm 720 725 725 725 725 775 860 880 880 725 950r mm 270 350 350 350 350 350 350 400 415 350 350s mm 240 260 265 280 290 325 340 390 375 450 450t mm 480 500 500 530 530 560 580 630 710 600 600
Flange mm – – – – – 730 750 800 880 780 800u mm 710 730 780 790 800 900 920 970 1060 970 1130v mm 910 1040 1140 1070 1160 1140 1190 1140 1430 1210 1440
w mm 1160 1320 1420 1340 1520 1510 1510 1420 1820 1500 1815x mm 1350 1450 1610 1480 1710 1640 1660 1550 2070 1700 2075y mm 1570 1690 1900 1710 1650 1910 1970 1815 2315 1890 2320z mm 1650 1780 1990 1800 2040 2010 2065 1905 2410 1980 2490
D1 mm 650 750 790 850 900 1000 1100 1300 1250 1600 1600D2 mm 600 600 740 747 800 900 1000 1200 1150 1300 1300
Km mm 1820 1975 2185 2020 2270 2280 2380 2350 2780 2520 3020H1 mm 490 460 590 500 570 570 650 640 730 660 760H2 mm 600 570 700 610 680 680 760 750 840 770 900H3 mm 710 710 820 720 850 860 880 870 1020 910 1090H4 mm 820 850 960 860 1020 1030 1070 1010 1210 1050 1280H5 mm 930 990 1120 1000 1190 1210 1250 1160 1410 1190 1460H6 mm 1120 1250 1410 1230 1470 1470 1490 1370 1730 1450 1800H7 mm 1420 1540 1740 1570 1820 1765 1830 1675 2185 1750 2190H8 mm 1500 1630 1840 1655 1895 1850 1925 1760 2265 1825 2335I1 lt 140 170 255 240 310 355 500 655 725 985 1185I2 lt 175 220 305 300 380 440 605 800 860 1205 1470I3 lt 210 285 365 360 490 580 710 960 1080 1490 1850I4 lt 250 345 435 440 600 715 910 1145 1315 1780 2230I5 lt 285 405 510 520 705 855 1085 1345 1560 2050 2595I6 lt 350 520 655 650 885 1060 1310 1625 1955 2575 3280I7 lt 450 650 815 845 1105 1295 1635 2030 2510 3175 4060I8 lt 475 690 865 895 1155 1360 1725 2140 2610 3330 4355
I total lt 520 760 980 980 1250 1490 1930 2430 2910 3920 4950
TABLE OF DIMENSIONS AS PER ILLUSTRATIONS
PRO-CLEAN® STRATIFIED TANK + 2WR
1) All size specifications have a tolerance range of +/- 3%
142
Corrugated pipeVolume of domes-tic hot water pipe
l 45 55 55 55 55 60 65 75 75 75 75
Length m 25 30 30 30 30 35 37 40 40 40 40Surface area m2 6.45 7.74 7.74 7.74 7.74 9.03 9.546 10.32 10.32 10.32 10.32
Tap output (hot water)T2 at 30 l/min °C 4 3 3 3 3 3 3 3 3 3 3T2 at 40 l/min °C 6 5 5 5 5 5 5 4 4 4 4T2 at 50 l/min °C 10 8 8 8 8 7 7 6 6 6 6T2 at 70 l/min °C – – – – – 11 11 10 9 9 8
Application range (Hot water)3 AW4 1-2 1-4 1-5 1-5 1-5 1-6 1-7 1-9 1-11 1-12 1-14
can be combined with ST 10-40 ST 10-40 ST 20-40ST 60K
ST 20-40ST 60K
ST 20-40ST 60K
ST 20-40ST 60K
ST 20-40ST 60K
ST 20-40ST 60K ST 60 ST 60 ST 60
HOT WATER TAP OUTPUT FROM PC WITH ONE CORRUGATED PIPE
1 Discharge capacity (hot water up to 38 °C) when the backup tank is loaded at 60 °C/50 °C.2 Temperature diªerence between the backup tank temperature and the domestic hot water tap temperature when the tank is half-full.3 Figures quoted are based on standard consumption values. Specific calculations are made for extreme consumption e.g. in swimming pools, saunas, etc.4 Number of flats (3 occupants/flat). Applicable only without circulation.
SLEEVE ASSIGNMENT
PRO-CLEAN® STRATIFIED TANK + 2WR
Hot water tap output and spherical exchanger sizing for Pro-Clean® stratified tank
TypePC500
PC800
PC1000B
PC1000S
PC1250
PC1500
PC2000
PC2500
PC3000
PC4000
PC5000
Tank volume l 520 760 980 980 1250 1490 1930 2430 2910 3920 4950
single Discharge capacity1 60°C l 400 600 810 810 1050 1290 1710 2150 2610 3560 4475
50°C l 285 430 580 580 750 920 1220 1535 1865 2540 3200
No. Label Dim. Use Comment
1 F (with flange 100) 1½" Spherical exchanger with layer washers for connection to a solar system 2a V4A (stainless-steel) 1" HW connection (stainless-steel) mandatory (possible with circula-
tion lance)2b
(2WR)V4A (stainless-steel) 1" HW connection (stainless-steel) mandatory (possibly with circulation
lance)3 ½" Ventilation mandatory4 EE (with inflow absorber 1½" Secondary heat source forward flow mandatory for secondary heat source5 ½" Sensor thimble for boiler sensor mandatory6 EE (with inflow absorber) 1½" Heating circuits forward flow according to hydraulic diagram7 H (for immersion heater) 2" Elec. immersion heater (reduced to 1½") with extension optional8 1½" Secondary heat source return mandatory for secondary heat source9 E (with inflow absorber) 1½" High temperature heating circuits return according to hydraulic diagram
10 E (with inflow absorber) 1½" Low temperature heating circuits return according to hydraulic diagram11 6 mm Contact sensor sleeve for solar sensor mandatory12 H (for immersion heater) 2" Elec. immersion heater (reduced to 1½") with extension optional
13a(2WR)
V4A (stainless-steel) 1" CW connection (stainless-steel) mandatory
13b V4A (stainless-steel) 1" CW connection (stainless-steel) mandatory15 6 mm Contact sensor sleeve for boiler thermometer optional16 6 mm Contact sensor sleeve usually for boiler sensor depending on hydraulic diagram17 6 mm Contact sensor sleeve depending on hydraulic diagram18 6 mm Contact sensor sleeve depending on hydraulic diagram19 ½" Drain mandatory22 F (flange) DN200 Flange for finned heat exchanger optional
30a E (with inflow absorber) 1½" Corrugated connection pipe, possibly with priority flap optional, only in combination with other tanks30b E (with inflow absorber) 1½" Corrugated connection pipe, possibly with priority flap
31 E (with inflow absorber) 1½" Corrugated connection pipe32 1½" Corrugated connection pipe33 1½" Corrugated connection pipe
143
Hot water tap output and spherical exchanger sizing for Pro-Clean®
TypePC 2WR
1250PC 2WR
1500PC 2WR
2000PC 2WR
2500PC 2WR
3000PC 2WR
4000PC 2WR
5000
Tank volume lt 1250 1490 1930 2430 2910 3920 4950single Discharge capacity
60°C lt 1050 1290 1710 2150 2610 3560 4475
50°C lt 750 920 1220 1535 1865 2540 3200
HOT WATER TAP OUTPUT FROM PC WITH TWO CORRUGATED PIPES
Continuous output KW 100 200 300
while heating drinking water from 10 to 45 °C and heating circuit forward flow temperature of 70 °C at the hot-water flow rate specified below l/h 2335 4658 6981
Hot water flow rate for the specified continuous output levels l/h 1920 3830 5740
Continuous output KW 100 200 300
while heating drinking water from 10 to 55 °C and heating circuit forward flow temperature of 70 °C at the hot-water flow rate specified below l/h 1830 3666 4500
Hot water flow rate for the specified continuous output levels l/h 2460 4920 7380
Tank size[l] 500 800 1000 1250 1500 2000 2500 3000 4000 5000
Volumetric flow [m3 / h] 2,7 3,2 3,4 3,4 4,0 4,3 4,4 4,5 4,9 5,0
CONTINUOUS OUTPUT WITH PRO-CLEAN® WITH TWO CORRUGATED PIPES (PC 2WR 2000)
MAX. WATER FLOW RATE WITH PRO-CLEAN® TANK WITHOUT MIXING THE LAYERS
Note on continuous output: The boiler's rated heat output must be greater or equal to continuous output. Plan fora circulation pump that is appropriate for the flow rate.
Note: The permissible total volumetric flow for each additional charged sleeve can be calculated as + 30% of the specified value per sleeve.
PRO-CLEAN® STRATIFIED TANK + 2WR
Corrugated pipeVolume of domestic hot water pipe
lt 2 x 55 2 x 60 2 x 65 2 x 75 2 x 75 2 x 75 2 x 75
Length m 2 x 30 2 x 35 2 x 37 2 x 40 2 x 40 2 x 40 2 x 40Surface area m2 2 x 7,74 2 x 9,03 2 x 9,546 2 x 10,32 2 x 10,32 2 x 10,32 2 x 10,32
1 Discharge capacity (hot water up to 38 °C) when the backup tank is loaded at 60 °C / 50 °C.2 Δt: Temperature diªerence between the backup tank temperature and the domestic hot water tap temperature when the tank is half-full.3 Figures quoted are based on standard consumption values. Specific calculations are made for extreme consumption e.g. in swimming pools, saunas, etc.4 Number of flats (3 occupants/flat). Applicable only without circulation.
Tap output (hot water) with two corrugated pipes connected in parallel
Type PC 2WR 1250
PC 2WR 1500
PC 2WR 2000
PC 2WR 2500
PC 2WR 3000
PC 2WR 4000
PC 2WR 5000
T2 at 30 l/min °C 2 2 2 2 2 2 2T2 at 40 l/min °C 2 2 2 2 2 2 2T2 at 50 l/min °C 3 3 3 3 3 3 3T2 at 70 l/min °C 7 6 6 5 5 5 5T2 at 90 l/min °C 9 8 8 7 7 6 6T2 at 110 l/min °C 11 8 8 8 7 7 7T2 at 130 l/min °C 13 12 12 11 10 10 10
Application range (Hot water)2 AW3 1-10 1-12 1-14 1-16 1-18 1-20 1-22
Can be combined withST 20-40 ST
60kST 20-40 ST
60kST 20-40 ST
60kST 20-40 ST
60k ST 60 ST 60 ST 60
144
Data while heating using a spherical exchanger (ST20) with a flow volume of 400 l/h and a collector surface area of 16 m2.13 kWh are required to obtain useable hot water at 40 °C (achieved within 98 min).
1 6
11 16 21 26 31 36 41 46 51 56 61 66 71 76 81 86 91 96 101
106
111
116
121
126
131
136
141
146
151
156
161
166
171
176
0
5
01
51
02
52
03
53
04
54
05
55
06
56
07
57
08
5T
4T
3T
2T
1T
Pro-Clean® 1000 litre
1,5 1,7 3,2 5,5 7 10,5 14 16,8 19,5
90
80
70
60
50
40
30
20
10
0
Rated load
Boile
r out
put (
kW) Boiler output
Rated load
SOLAR STRATIFIED CHARGING
Tem
p. (°
C)
RATED LOAD AT 60 °C TANK TEMPERATURE
PRO-CLEAN® STRATIFIED TANK + 2WR
sphe
rical
exc
hang
er
Temp 1 Temp 2 Temp 3 Temp 4 Temp 5 Solar VL9 Solar RL
Time/min
145
020406080100120140160180200220240260280300320340360380400
0,13 0,19 0,26 0,32 0,39 0,45 0,52 0,58 0,65 0,71 0,78 0,84 0,91 0,97 1,03
0,6 0,9 1,2 1,5 1,8 2,1 2,4 2,7 3 3,3 3,6 3,9 4,2 4,5 4,8
10 15 20 25 30 35 40 45 50 55 60 65 70 75 80
PC 500
PC 800PC 1000PC 1250
PC 1500
PC 2000
PC 2500PC 3000PC 4000PC 5000
Concentration limits for diverse drinking water constituents when using PRO-CLEAN® corrugated stainless-steel pipe
pH value 6.5-9.5
Sulfate 250 mg/l
Sodium 200 mg/l
Manganese 0.5 mg/l
Iron 0,2 mg/l
Nitrate 50 mg/l
Chloride 200 (2501) mg/l
Amonium 0,5 mg/l
Nitrite 0.1 mg/l
Do not exceed these values!1 Austria: 200 mg/l, Germany 250 mg/l
CONSTITUENT CONCENTRATION LIMITS
PRESSURE DROP OF CORRUGATED PIPE DN 40
PRO-CLEAN® STRATIFIED TANK + 2WR
Tap quantity and flow velocity
Flow velocity [m/s]
Tap quantity [m3/h]
Tap quantity [l/min]
Pres
sure
dro
p in
[mba
r]Flow velocity < 0.7 m/s
146
Reference house: 9 kW heat load at - 15 °C ambient temperature Location: Würzburg/Germany, collector orientation 0° south, 30° tilt, average heating forward flow temperature 33 °C
6/4"
6/4"
6/4"
6/4"
6/4"
6/4"
6/4"
6/4"
6/4"
6/4"
6/4"
6/4"
45° 45° 45° 45°
51
02
52
03
53
04
54
05
55
06
56
²m 21 ²m 51 ²m 81 ²m 42 ²m 03 ²m 04 ²m 05 ²m 06
PC 500 lt ofwhich 160 lt HW
PC 800 old ofwhich 250 lt HW
PC 1000 lt ofwhich 250 lt HW
PC 1250 lt ofwhich 250 lt HW
optional:priority flap5/4 ” on site
piping
Expansion backup tank
Corrugated connection pipe Corrugated connection pipe
Expansion backup tankStratified tank
optional:priority flap5/4 ” on site
piping
PC 1500 lt ofwhich 320 lt HW
PC 2000 lt ofwhich 320 lt HW
PC 2500 lt ofwhich 320 lt HW
practical tank size
PC 3000 lt ofwhich 400 lt HW
A stratified tank can be expanded using a maximum of two PS expansion tanks (possible for a tank capacity of up to 1500 l, above this value piping has to be fitted on site). Installation of fittings may be required on site.
Recommended for up to 50 kW only. Tank volume may be tripled at a maximum. Four pieces of corrugated connection pipe are required for each expansion tank. A priority flap may optionally be used.
EXPANSION WITH BACKUP TANK
SIZE DETERMINATION WITH SOLAR COLLECTORS
PRO-CLEAN® STRATIFIED TANK + 2WRSo
lar r
oofin
g in
% fo
r spa
ce h
eatin
g an
d ho
t wat
er
(roof
in s
umm
er m
onth
s 10
0%)
m2 Collector surface area
147
DIAGRAM 1
PRO-CLEAN® STRATIFIED TANK
EX
T
P
T
M
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 193
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 19
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15
5 16 17 18 11 19
31 32 3330
12
3
131098764215
5 16 17 18 11 19
31 32 3330
12
33
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
60°C
Th
MM
11EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
60°C
Th
3130
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
11
M
M
3231
38°-
65°CTh
1310987642
15
5 16 17 18 193
12
11
M
M
EX
T
P
T
M
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
3231
M
WW
Rück
schl
agkl
appe
Um
wäl
zpum
peAb
sper
rven
til
Drei
weg
vent
il
Fühl
er
Ther
mo-
, Man
omet
er
Sich
erhe
itsve
ntil
M
Zirk
ulat
ion
Kaltw
asse
rW
arm
was
ser
Hei
zung
srüc
klau
f
Hei
zung
svor
lauf
Sola
r-RL
Sola
r-VL
Steu
erun
g
Verb
indu
ngsw
ellro
hrVo
rran
gkla
ppe
1310987642FE
-Hah
n
PRO
CLE
AN
15
5 16 17 18 193
12
Th 38°-
65°C
Brau
chw
asse
r-M
isch
vent
il
KW
Sche
ma
Nr.:
PC_
17/0
7
11
Zirk
. Pum
pe
PWT
30
38°-
65°C
ThKW
M
� 55
°C
1310987642
15
5 16 17 18 193
12
11
30
M
38°-
65°CTh
RR
RR
RR
R
R
R
RR
RR
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
148
DIAGRAM 2
PRO-CLEAN® STRATIFIED TANK
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
EX
T
P
T
M
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 193
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 19
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15
5 16 17 18 11 19
31 32 3330
12
3
131098764215
5 16 17 18 11 19
31 32 3330
12
33
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
60°C
Th
MM
11EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
60°C
Th
3130
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
11
M
M
3231
38°-
65°CTh
1310987642
15
5 16 17 18 193
12
11
M
M
EX
T
P
T
M
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
3231
M
WW
Rück
schl
agkl
appe
Um
wäl
zpum
peAb
sper
rven
til
Drei
weg
vent
il
Fühl
er
Ther
mo-
, Man
omet
er
Sich
erhe
itsve
ntil
M
Zirk
ulat
ion
Kaltw
asse
rW
arm
was
ser
Hei
zung
srüc
klau
f
Hei
zung
svor
lauf
Sola
r-RL
Sola
r-VL
Steu
erun
g
Verb
indu
ngsw
ellro
hrVo
rran
gkla
ppe
1310987642FE
-Hah
n
PRO
CLE
AN
15
5 16 17 18 193
12
Th 38°-
65°C
Brau
chw
asse
r-M
isch
vent
il
KW
Sche
ma
Nr.:
PC_
17/0
7
11
Zirk
. Pum
pe
PWT
30
38°-
65°C
ThKW
M
� 55
°C
1310987642
15
5 16 17 18 193
12
11
30
M
38°-
65°CTh
RR
RR
RR
R
R
R
RR
RR
149
DIAGRAM 3
PRO-CLEAN® STRATIFIED TANK
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
EX
T
P
T
M
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 193
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 19
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15
5 16 17 18 11 19
31 32 3330
12
3
131098764215
5 16 17 18 11 19
31 32 3330
12
33
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
60°C
Th
MM
11EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
60°C
Th
3130
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
11
M
M
3231
38°-
65°CTh
1310987642
15
5 16 17 18 193
12
11
M
M
EX
T
P
T
M
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
3231
M
WW
Rück
schl
agkl
appe
Um
wäl
zpum
peAb
sper
rven
til
Drei
weg
vent
il
Fühl
er
Ther
mo-
, Man
omet
er
Sich
erhe
itsve
ntil
M
Zirk
ulat
ion
Kaltw
asse
rW
arm
was
ser
Hei
zung
srüc
klau
f
Hei
zung
svor
lauf
Sola
r-RL
Sola
r-VL
Steu
erun
g
Verb
indu
ngsw
ellro
hrVo
rran
gkla
ppe
1310987642FE
-Hah
n
PRO
CLE
AN
15
5 16 17 18 193
12
Th 38°-
65°C
Brau
chw
asse
r-M
isch
vent
il
KW
Sche
ma
Nr.:
PC_
17/0
7
11
Zirk
. Pum
pe
PWT
30
38°-
65°C
ThKW
M
� 55
°C
1310987642
15
5 16 17 18 193
12
11
30
M
38°-
65°CTh
RR
RR
RR
R
R
R
RR
RR
150
DIAGRAM 4
PRO-CLEAN® STRATIFIED TANK
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
EX
T
P
T
M
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 193
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 19
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15
5 16 17 18 11 19
31 32 3330
12
3
131098764215
5 16 17 18 11 19
31 32 3330
12
33
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
60°C
Th
MM
11EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
60°C
Th
3130
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
11
M
M
3231
38°-
65°CTh
1310987642
15
5 16 17 18 193
12
11
M
M
EX
T
P
T
M
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
3231
M
WW
Rück
schl
agkl
appe
Um
wäl
zpum
peAb
sper
rven
til
Drei
weg
vent
il
Fühl
er
Ther
mo-
, Man
omet
er
Sich
erhe
itsve
ntil
M
Zirk
ulat
ion
Kaltw
asse
rW
arm
was
ser
Hei
zung
srüc
klau
f
Hei
zung
svor
lauf
Sola
r-RL
Sola
r-VL
Steu
erun
g
Verb
indu
ngsw
ellro
hrVo
rran
gkla
ppe
1310987642FE
-Hah
n
PRO
CLE
AN
15
5 16 17 18 193
12
Th 38°-
65°C
Brau
chw
asse
r-M
isch
vent
il
KW
Sche
ma
Nr.:
PC_
17/0
7
11
Zirk
. Pum
pe
PWT
30
38°-
65°C
ThKW
M
� 55
°C
1310987642
15
5 16 17 18 193
12
11
30
M
38°-
65°CTh
RR
RR
RR
R
R
R
RR
RR
151
DIAGRAM 5
PRO-CLEAN® STRATIFIED TANK
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
EX
T
P
T
M
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 193
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 19
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15
5 16 17 18 11 19
31 32 3330
12
3
131098764215
5 16 17 18 11 19
31 32 3330
12
33
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
60°C
Th
MM
11EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
60°C
Th
3130
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
11
M
M
3231
38°-
65°CTh
1310987642
15
5 16 17 18 193
12
11
M
M
EX
T
P
T
M
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
3231
M
WW
Rück
schl
agkl
appe
Um
wäl
zpum
peAb
sper
rven
til
Drei
weg
vent
il
Fühl
er
Ther
mo-
, Man
omet
er
Sich
erhe
itsve
ntil
M
Zirk
ulat
ion
Kaltw
asse
rW
arm
was
ser
Hei
zung
srüc
klau
f
Hei
zung
svor
lauf
Sola
r-RL
Sola
r-VL
Steu
erun
g
Verb
indu
ngsw
ellro
hrVo
rran
gkla
ppe
1310987642FE
-Hah
n
PRO
CLE
AN
15
5 16 17 18 193
12
Th 38°-
65°C
Brau
chw
asse
r-M
isch
vent
il
KW
Sche
ma
Nr.:
PC_
17/0
7
11
Zirk
. Pum
pe
PWT
30
38°-
65°C
ThKW
M
� 55
°C
1310987642
15
5 16 17 18 193
12
11
30
M
38°-
65°CTh
RR
RR
RR
R
R
R
RR
RR
152
DIAGRAM 6
PRO-CLEAN® STRATIFIED TANK
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
EX
T
P
T
M
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 193
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 19
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15
5 16 17 18 11 19
31 32 3330
12
3
131098764215
5 16 17 18 11 19
31 32 3330
12
33
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
60°C
Th
MM
11EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
60°C
Th
3130
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
11
M
M
3231
38°-
65°CTh
1310987642
15
5 16 17 18 193
12
11
M
M
EX
T
P
T
M
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
3231
M
WW
Rück
schl
agkl
appe
Um
wäl
zpum
peAb
sper
rven
til
Drei
weg
vent
il
Fühl
er
Ther
mo-
, Man
omet
er
Sich
erhe
itsve
ntil
M
Zirk
ulat
ion
Kaltw
asse
rW
arm
was
ser
Hei
zung
srüc
klau
f
Hei
zung
svor
lauf
Sola
r-RL
Sola
r-VL
Steu
erun
g
Verb
indu
ngsw
ellro
hrVo
rran
gkla
ppe
1310987642FE
-Hah
n
PRO
CLE
AN
15
5 16 17 18 193
12
Th 38°-
65°C
Brau
chw
asse
r-M
isch
vent
il
KW
Sche
ma
Nr.:
PC_
17/0
7
11
Zirk
. Pum
pe
PWT
30
38°-
65°C
ThKW
M
� 55
°C
1310987642
15
5 16 17 18 193
12
11
30
M
38°-
65°CTh
RR
RR
RR
R
R
R
RR
RR
153
DIAGRAM 7
PRO-CLEAN® STRATIFIED TANK
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
EX
T
P
T
M
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 193
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 19
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15
5 16 17 18 11 19
31 32 3330
12
3
131098764215
5 16 17 18 11 19
31 32 3330
12
33
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
60°C
Th
MM
11EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
60°C
Th
3130
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
11
M
M
3231
38°-
65°CTh
1310987642
15
5 16 17 18 193
12
11
M
M
EX
T
P
T
M
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
3231
M
WW
Rück
schl
agkl
appe
Um
wäl
zpum
peAb
sper
rven
til
Drei
weg
vent
il
Fühl
er
Ther
mo-
, Man
omet
er
Sich
erhe
itsve
ntil
M
Zirk
ulat
ion
Kaltw
asse
rW
arm
was
ser
Hei
zung
srüc
klau
f
Hei
zung
svor
lauf
Sola
r-RL
Sola
r-VL
Steu
erun
g
Verb
indu
ngsw
ellro
hrVo
rran
gkla
ppe
1310987642FE
-Hah
n
PRO
CLE
AN
15
5 16 17 18 193
12
Th 38°-
65°C
Brau
chw
asse
r-M
isch
vent
il
KW
Sche
ma
Nr.:
PC_
17/0
7
11
Zirk
. Pum
pe
PWT
30
38°-
65°C
ThKW
M
� 55
°C
1310987642
15
5 16 17 18 193
12
11
30
M
38°-
65°CTh
RR
RR
RR
R
R
R
RR
RR
154
DIAGRAM 8
PRO-CLEAN® STRATIFIED TANK
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
EX
T
P
T
M
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 193
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 19
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15
5 16 17 18 11 19
31 32 3330
12
3
131098764215
5 16 17 18 11 19
31 32 3330
12
33
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
60°C
Th
MM
11EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
60°C
Th
3130
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
11
M
M
3231
38°-
65°CTh
1310987642
15
5 16 17 18 193
12
11
M
M
EX
T
P
T
M
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
3231
M
WW
Rück
schl
agkl
appe
Um
wäl
zpum
peAb
sper
rven
til
Drei
weg
vent
il
Fühl
er
Ther
mo-
, Man
omet
er
Sich
erhe
itsve
ntil
M
Zirk
ulat
ion
Kaltw
asse
rW
arm
was
ser
Hei
zung
srüc
klau
f
Hei
zung
svor
lauf
Sola
r-RL
Sola
r-VL
Steu
erun
g
Verb
indu
ngsw
ellro
hrVo
rran
gkla
ppe
1310987642FE
-Hah
n
PRO
CLE
AN
15
5 16 17 18 193
12
Th 38°-
65°C
Brau
chw
asse
r-M
isch
vent
il
KW
Sche
ma
Nr.:
PC_
17/0
7
11
Zirk
. Pum
pe
PWT
30
38°-
65°C
ThKW
M
� 55
°C
1310987642
15
5 16 17 18 193
12
11
30
M
38°-
65°CTh
RR
RR
RR
R
R
R
RR
RR
155
DIAGRAM 9
PRO-CLEAN® STRATIFIED TANK
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
EX
T
P
T
M
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 193
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 19
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15
5 16 17 18 11 19
31 32 3330
12
3
131098764215
5 16 17 18 11 19
31 32 3330
12
33
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
60°C
Th
MM
11EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
60°C
Th
3130
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
11
M
M
3231
38°-
65°CTh
1310987642
15
5 16 17 18 193
12
11
M
M
EX
T
P
T
M
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
3231
M
WW
Rück
schl
agkl
appe
Um
wäl
zpum
peAb
sper
rven
til
Drei
weg
vent
il
Fühl
er
Ther
mo-
, Man
omet
er
Sich
erhe
itsve
ntil
M
Zirk
ulat
ion
Kaltw
asse
rW
arm
was
ser
Hei
zung
srüc
klau
f
Hei
zung
svor
lauf
Sola
r-RL
Sola
r-VL
Steu
erun
g
Verb
indu
ngsw
ellro
hrVo
rran
gkla
ppe
1310987642FE
-Hah
n
PRO
CLE
AN
15
5 16 17 18 193
12
Th 38°-
65°C
Brau
chw
asse
r-M
isch
vent
il
KW
Sche
ma
Nr.:
PC_
17/0
7
11
Zirk
. Pum
pe
PWT
30
38°-
65°C
ThKW
M
� 55
°C
1310987642
15
5 16 17 18 193
12
11
30
M
38°-
65°CTh
RR
RR
RR
R
R
R
RR
RR
156
DIAGRAM 10
PRO-CLEAN® STRATIFIED TANK
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
EX
T
P
T
M
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 193
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 19
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15
5 16 17 18 11 19
31 32 3330
12
3
131098764215
5 16 17 18 11 19
31 32 3330
12
33
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
60°C
Th
MM
11EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
60°C
Th
3130
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
11
M
M
3231
38°-
65°CTh
1310987642
15
5 16 17 18 193
12
11
M
M
EX
T
P
T
M
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
3231
M
WW
Rück
schl
agkl
appe
Um
wäl
zpum
peAb
sper
rven
til
Drei
weg
vent
il
Fühl
er
Ther
mo-
, Man
omet
er
Sich
erhe
itsve
ntil
M
Zirk
ulat
ion
Kaltw
asse
rW
arm
was
ser
Hei
zung
srüc
klau
f
Hei
zung
svor
lauf
Sola
r-RL
Sola
r-VL
Steu
erun
g
Verb
indu
ngsw
ellro
hrVo
rran
gkla
ppe
1310987642FE
-Hah
n
PRO
CLE
AN
15
5 16 17 18 193
12
Th 38°-
65°C
Brau
chw
asse
r-M
isch
vent
il
KW
Sche
ma
Nr.:
PC_
17/0
7
11
Zirk
. Pum
pe
PWT
30
38°-
65°C
ThKW
M
� 55
°C
1310987642
15
5 16 17 18 193
12
11
30
M
38°-
65°CTh
RR
RR
RR
R
R
R
RR
RR
157
DIAGRAM 11
PRO-CLEAN® STRATIFIED TANK
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
EX
T
P
T
M
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 193
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 19
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15
5 16 17 18 11 19
31 32 3330
12
3
131098764215
5 16 17 18 11 19
31 32 3330
12
33
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
60°C
Th
MM
11EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
60°C
Th
3130
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
11
M
M
3231
38°-
65°CTh
1310987642
15
5 16 17 18 193
12
11
M
M
EX
T
P
T
M
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
3231
M
WW
Rück
schl
agkl
appe
Um
wäl
zpum
peAb
sper
rven
til
Drei
weg
vent
il
Fühl
er
Ther
mo-
, Man
omet
er
Sich
erhe
itsve
ntil
M
Zirk
ulat
ion
Kaltw
asse
rW
arm
was
ser
Hei
zung
srüc
klau
f
Hei
zung
svor
lauf
Sola
r-RL
Sola
r-VL
Steu
erun
g
Verb
indu
ngsw
ellro
hrVo
rran
gkla
ppe
1310987642FE
-Hah
n
PRO
CLE
AN
15
5 16 17 18 193
12
Th 38°-
65°C
Brau
chw
asse
r-M
isch
vent
il
KW
Sche
ma
Nr.:
PC_
17/0
7
11
Zirk
. Pum
pe
PWT
30
38°-
65°C
ThKW
M
� 55
°C
1310987642
15
5 16 17 18 193
12
11
30
M
38°-
65°CTh
RR
RR
RR
R
R
R
RR
RR
158
DIAGRAM 12
PRO-CLEAN® STRATIFIED TANK
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
EX
T
P
T
M
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 193
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 19
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15
5 16 17 18 11 19
31 32 3330
12
3
131098764215
5 16 17 18 11 19
31 32 3330
12
33
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
60°C
Th
MM
11EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
60°C
Th
3130
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
11
M
M
3231
38°-
65°CTh
1310987642
15
5 16 17 18 193
12
11
M
M
EX
T
P
T
M
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
3231
M
WW
Rück
schl
agkl
appe
Um
wäl
zpum
peAb
sper
rven
til
Drei
weg
vent
il
Fühl
er
Ther
mo-
, Man
omet
er
Sich
erhe
itsve
ntil
M
Zirk
ulat
ion
Kaltw
asse
rW
arm
was
ser
Hei
zung
srüc
klau
f
Hei
zung
svor
lauf
Sola
r-RL
Sola
r-VL
Steu
erun
g
Verb
indu
ngsw
ellro
hrVo
rran
gkla
ppe
1310987642FE
-Hah
n
PRO
CLE
AN
15
5 16 17 18 193
12
Th 38°-
65°C
Brau
chw
asse
r-M
isch
vent
il
KW
Sche
ma
Nr.:
PC_
17/0
7
11
Zirk
. Pum
pe
PWT
30
38°-
65°C
ThKW
M
� 55
°C
1310987642
15
5 16 17 18 193
12
11
30
M
38°-
65°CTh
RR
RR
RR
R
R
R
RR
RR
159
DIAGRAM 13
PRO-CLEAN® STRATIFIED TANK
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
EX
T
P
T
M
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 193
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 19
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15
5 16 17 18 11 19
31 32 3330
12
3
131098764215
5 16 17 18 11 19
31 32 3330
12
33
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
60°C
Th
MM
11EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
60°C
Th
3130
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
11
M
M
3231
38°-
65°CTh
1310987642
15
5 16 17 18 193
12
11
M
M
EX
T
P
T
M
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
3231
M
WW
Rück
schl
agkl
appe
Um
wäl
zpum
peAb
sper
rven
til
Drei
weg
vent
il
Fühl
er
Ther
mo-
, Man
omet
er
Sich
erhe
itsve
ntil
M
Zirk
ulat
ion
Kaltw
asse
rW
arm
was
ser
Hei
zung
srüc
klau
f
Hei
zung
svor
lauf
Sola
r-RL
Sola
r-VL
Steu
erun
g
Verb
indu
ngsw
ellro
hrVo
rran
gkla
ppe
1310987642FE
-Hah
n
PRO
CLE
AN
15
5 16 17 18 193
12
Th 38°-
65°C
Brau
chw
asse
r-M
isch
vent
il
KW
Sche
ma
Nr.:
PC_
17/0
7
11
Zirk
. Pum
pe
PWT
30
38°-
65°C
ThKW
M
� 55
°C
1310987642
15
5 16 17 18 193
12
11
30
M
38°-
65°CTh
RR
RR
RR
R
R
R
RR
RR
160
DIAGRAM 14
PRO-CLEAN® STRATIFIED TANK
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
EX
T
P
T
M
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 193
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 19
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15
5 16 17 18 11 19
31 32 3330
12
3
131098764215
5 16 17 18 11 19
31 32 3330
12
33
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
60°C
Th
MM
11EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
60°C
Th
3130
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
11
M
M
3231
38°-
65°CTh
1310987642
15
5 16 17 18 193
12
11
M
M
EX
T
P
T
M
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
3231
M
WW
Rück
schl
agkl
appe
Um
wäl
zpum
peAb
sper
rven
til
Drei
weg
vent
il
Fühl
er
Ther
mo-
, Man
omet
er
Sich
erhe
itsve
ntil
M
Zirk
ulat
ion
Kaltw
asse
rW
arm
was
ser
Hei
zung
srüc
klau
f
Hei
zung
svor
lauf
Sola
r-RL
Sola
r-VL
Steu
erun
g
Verb
indu
ngsw
ellro
hrVo
rran
gkla
ppe
1310987642FE
-Hah
n
PRO
CLE
AN
15
5 16 17 18 193
12
Th 38°-
65°C
Brau
chw
asse
r-M
isch
vent
il
KW
Sche
ma
Nr.:
PC_
17/0
7
11
Zirk
. Pum
pe
PWT
30
38°-
65°C
ThKW
M
� 55
°C
1310987642
15
5 16 17 18 193
12
11
30
M
38°-
65°CTh
RR
RR
RR
R
R
R
RR
RR
5 Bo
iler s
enso
r
17 H
eatin
g re
gula
tor m
inim
um
limit
sens
or
18 S
olid
fuel
boi
ler s
enso
r
161
DIAGRAM 15
PRO-CLEAN® STRATIFIED TANK
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
EX
T
P
T
M
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 193
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 19
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15
5 16 17 18 11 19
31 32 3330
12
3
131098764215
5 16 17 18 11 19
31 32 3330
12
33
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
60°C
Th
MM
11EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
60°C
Th
3130
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
11
M
M
3231
38°-
65°CTh
1310987642
15
5 16 17 18 193
12
11
M
M
EX
T
P
T
M
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
3231
M
WW
Rück
schl
agkl
appe
Um
wäl
zpum
peAb
sper
rven
til
Drei
weg
vent
il
Fühl
er
Ther
mo-
, Man
omet
er
Sich
erhe
itsve
ntil
M
Zirk
ulat
ion
Kaltw
asse
rW
arm
was
ser
Hei
zung
srüc
klau
f
Hei
zung
svor
lauf
Sola
r-RL
Sola
r-VL
Steu
erun
g
Verb
indu
ngsw
ellro
hrVo
rran
gkla
ppe
1310987642FE
-Hah
n
PRO
CLE
AN
15
5 16 17 18 193
12
Th 38°-
65°C
Brau
chw
asse
r-M
isch
vent
il
KW
Sche
ma
Nr.:
PC_
17/0
7
11
Zirk
. Pum
pe
PWT
30
38°-
65°C
ThKW
M
� 55
°C
1310987642
15
5 16 17 18 193
12
11
30
M
38°-
65°CTh
RR
RR
RR
R
R
R
RR
RR
162
EX
T
P
T
M
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 193
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 19
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15
5 16 17 18 11 19
31 32 3330
12
3
131098764215
5 16 17 18 11 19
31 32 3330
12
33
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
60°C
Th
MM
11EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
60°C
Th
3130
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
11
M
M
3231
38°-
65°CTh
1310987642
15
5 16 17 18 193
12
11
M
M
EX
T
P
T
M
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
3231
M
WW
Rück
schl
agkl
appe
Um
wäl
zpum
peAb
sper
rven
til
Drei
weg
vent
il
Fühl
er
Ther
mo-
, Man
omet
er
Sich
erhe
itsve
ntil
M
Zirk
ulat
ion
Kaltw
asse
rW
arm
was
ser
Hei
zung
srüc
klau
f
Hei
zung
svor
lauf
Sola
r-RL
Sola
r-VL
Steu
erun
g
Verb
indu
ngsw
ellro
hrVo
rran
gkla
ppe
1310987642FE
-Hah
n
PRO
CLE
AN
15
5 16 17 18 193
12
Th 38°-
65°C
Brau
chw
asse
r-M
isch
vent
il
KW
Sche
ma
Nr.:
PC_
17/0
7
11
Zirk
. Pum
pe
PWT
30
38°-
65°C
ThKW
M
� 55
°C
1310987642
15
5 16 17 18 193
12
11
30
M
38°-
65°CTh
RR
RR
RR
R
R
R
RR
RR
Up
to 5
kW
From
5 k
W
DIAGRAM 16
PRO-CLEAN® STRATIFIED TANK
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
EX
T
P
T
M
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 193
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15 5 16 17 18 11 19
31 32 3330
12
EX
T
P
T
MM
EX
1310987642
38°-
65°CTh
15
5 16 17 18 11 19
31 32 3330
12
3
131098764215
5 16 17 18 11 19
31 32 3330
12
33
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
M M
EX
T
P
T
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
60°C
Th
MM
11EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
60°C
Th
3130
EX
T
P
T
MM
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
38°-
65°CTh
EX
131098764215
5 16 17 18 193
12
11
M
M
3231
38°-
65°CTh
1310987642
15
5 16 17 18 193
12
11
M
M
EX
T
P
T
M
38°-
65°CTh
EX
131098764215
5 16 17 18 11 193
12
3231
M
WW
Rück
schl
agkl
appe
Um
wäl
zpum
peAb
sper
rven
til
Drei
weg
vent
il
Fühl
er
Ther
mo-
, Man
omet
er
Sich
erhe
itsve
ntil
M
Zirk
ulat
ion
Kaltw
asse
rW
arm
was
ser
Hei
zung
srüc
klau
f
Hei
zung
svor
lauf
Sola
r-RL
Sola
r-VL
Steu
erun
g
Verb
indu
ngsw
ellro
hrVo
rran
gkla
ppe
1310987642FE
-Hah
n
PRO
CLE
AN
15
5 16 17 18 193
12
Th 38°-
65°C
Brau
chw
asse
r-M
isch
vent
il
KW
Sche
ma
Nr.:
PC_
17/0
7
11
Zirk
. Pum
pe
PWT
30
38°-
65°C
ThKW
M
� 55
°C
1310987642
15
5 16 17 18 193
12
11
30
M
38°-
65°CTh
RR
RR
RR
R
R
R
RR
RR
163
PRO-CLEAN® 2WR STRATIFIED TANKDIAGRAM 1
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
R
164
PRO-CLEAN® 2WR STRATIFIED TANKDIAGRAM 2
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
R
165
PRO-HEAT STRATIFIED TANK
Pro-Heat stratified tank with spherical exchanger connec-tion for heatingMulti-functional stratified tank system (only in combination with a spherical exchanger) made of S 235 JR steel for heating. Backup tank with optimum stratified charging without mixing the tank with tapping devices. Inflow absorbers ensure optimum retention of stratification. Expandable with PS heating tank.
Area of use• In solar systems and backup heating• In biomass systems as a backup tank• In heat pump systems as a tank for heating
Advantages• Optimum use of solar energy for heating• Simple functional concept without complex technology (intuitive use) • Long service life• Improved e�ciency for every heating system (solar, biomass, heat pump)• Space-saving design with minimum heat loss (polyester fibre fleece insulation)
Technical description
Max. backup operating pressure 3 bar
Heating/boiler connection 1½" female thread* with inflow absorber
Thermometer and sensor connection ½" female thread/6 mm contact sensor sleeve
Max. temperature 110 °C
Specifications
Type Total height with
insulation1
Ø withinsulation1
Ø withoutinsulation1
Width A with
insulation1
Width B with
insulation1
Tilt height1 Weight Item no.
PH 500 1860 mm 850 mm 650 mm 1020 mm 1175 mm 1820 mm 100 kg 1610823
PH 800 2010 mm 950 mm 750 mm 1105 mm 1280 mm 1975 mm 120 kg 1610824
PH 1000B 2050 mm 1050 mm 850 mm 1180 mm 1380 mm 2020 mm 140 kg 1610825
PH 1000S 2220 mm 990 mm 790 mm 1140 mm 1320 mm 2185 mm 140 kg 1610826
PH 1250 2300 mm 1100 mm 900 mm 1235 mm 1440 mm 2270 mm 170 kg 1610827
PH 1500 2290 mm 1200 mm 1000 mm 1320 mm 1540 mm 2280 mm 190 kg 1610828
PH 2000 2380 mm 1300 mm 1100 mm 1400 mm 1640 mm 2380 mm 240 kg 1610829
PH 2500 2270 mm 1500 mm 1300 mm 1600 mm 1840 mm 2350 mm 300 kg 1610830
PH 3000 2760 mm 1470 mm 1250 mm 1530 mm 1790 mm 2780 mm 365 kg 1610831
PH 4000 2390 mm 1820 mm 1600 mm 1830 mm 2130 mm 2520 mm 420 kg 1610832
PH 5000 2900 mm 1820 mm 1600 mm 1830 mm 2130 mm 3020 mm 500 kg 1610833
PRODUCT DESCRIPTION
SPECIFICATIONS
1) All size specifications have a tolerance range of +/- 3%
166
PRO-HEAT STRATIFIED TANK
Insulation thickness of PH 3000, PH 4000 and PH 5000 is 110 mm.
Volume at sleeveSleeve
no.Sleeve height
(measured from the lid)
Volume
4 H1 l16 H2 l27 H3 l38 H4 l49 H5 l510 H6 l612 H7 l713 H8 l8
Total volume
DIMENSIONS
Pro-Heattank
*
* only for PH 1000S
¾" Sleeve closed
Insulation
Km
Insulation
Flan
ge
Cross section
optional: Elec. heating ext. (10 cm) ifelec. immersion heater used
spherical exch. flange
167
PRO-HEAT STRATIFIED TANK
Position Unit of measure
PH500
PH 800
PH 1000S
PH 1000B
PH 1250
PH 1500
PH 2000
PH 2500
PH 3000
PH 4000
PH 5000
a mm 1540 1540 1540 1540 1560 1600 1610 1660 2120 2010 2010b mm 1150 1150 1150 1150 1170 1210 1220 1270 1560 1450 1450c mm 720 720 720 720 740 780 790 840 1030 920 920d mm 290 290 290 290 310 350 360 410 400 290 290e mm 260 280 280 295 305 340 355 410 395 465 465f mm 340 370 380 380 380 425 450 495 475 540 610
g mm 640 660 710 720 730 720 790 800 930 840 1000h mm 830 920 1000 950 1010 980 1030 1010 1250 1100 1340i mm 940 1060 1160 1090 1180 1160 1210 1160 1450 1240 1520j mm 1050 1200 1300 1230 1350 1330 1400 1300 1640 1380 1710
k mm 1160 1340 1420 1340 1520 1510 1520 1420 1820 1520 1900l mm 1270 1450 1530 1450 1630 1620 1630 1530 1930 1630 2040
m mm 1650 1780 1990 1790 2040 2005 2080 1920 2430 1980 2490n mm 1760 1910 2120 1950 2200 2190 2280 2170 2660 2290 2800
o1 mm 1540 1680 1900 1680 1700 1890 1950 1810 2200 1700 2300o2 mm – – 1680 – – – – – – – –p mm 1150 1170 1170 1170 1170 1280 1370 1360 1460 1170 1600q mm 720 725 725 725 725 775 860 880 880 725 950r mm 270 350 350 350 350 350 350 400 415 350 350s mm 240 260 265 280 290 325 340 390 375 450 450t mm 480 500 500 530 530 560 580 630 710 600 600
Flange mm 730 750 800 880 780 800
u mm 710 730 780 790 800 900 920 970 1060 970 1130v mm 910 1040 1140 1070 1160 1140 1190 1140 1430 1210 1440
w mm 1160 1320 1420 1340 1520 1510 1510 1420 1820 1500 1815x mm 1350 1450 1610 1480 1710 1640 1660 1550 2070 1700 2075y mm 1570 1690 1900 1710 1650 1910 1970 1815 2315 1890 2320z mm 1650 1780 1990 1800 2040 2010 2065 1905 2410 1980 2490
D1 mm 650 750 790 850 900 1000 1100 1300 1250 1600 1600D2 mm 600 600 740 747 800 900 1000 1200 1150 1300 1300Km mm 1820 1975 2185 2020 2270 2280 2380 2350 2780 2520 3020H1 mm 490 460 590 500 570 570 650 640 730 660 760H2 mm 600 570 700 610 680 680 760 750 840 770 900H3 mm 710 710 820 720 850 860 880 870 1020 910 1090H4 mm 820 850 960 860 1020 1030 1070 1010 1210 1050 1280H5 mm 930 990 1120 1000 1190 1210 1250 1160 1410 1190 1460H6 mm 1120 1250 1410 1230 1470 1470 1490 1370 1730 1450 1800H7 mm 1420 1540 1740 1570 1820 1765 1830 1675 2185 1750 2190H8 mm 1500 1630 1840 1655 1895 1850 1925 1760 2265 1825 2335I1 lt 140 170 255 240 310 355 500 655 725 985 1185I2 lt 175 220 305 300 380 440 605 800 860 1205 1470I3 lt 210 285 365 360 490 580 710 960 1080 1490 1850I4 lt 250 345 435 440 600 715 910 1145 1315 1780 2230I5 lt 285 405 510 520 705 855 1085 1345 1560 2050 2595I6 lt 350 520 655 650 885 1060 1310 1625 1955 2575 3280I7 lt 450 650 815 845 1105 1295 1635 2030 2510 3175 4060I8 lt 475 690 865 895 1155 1360 1725 2140 2610 3330 4355
V total lt 520 760 980 980 1250 1490 1930 2430 2910 3920 4950
TABLE OF DIMENSIONS AS PER ILLUSTRATIONS
1) All size specifications have a tolerance range of +/- 3%
168
PRO-HEAT STRATIFIED TANK
No. Designation Dimension Use Comment
1 F (with flange 100) 1½" Spherical exchanger with layer washers for connection to a solar system
2 1½" Heating circuits forward flow according to hydraulic diagram
3 ½" Venting mandatory
4 EE (with inflow absorber) 1½" Secondary heat source forward flow mandatory for secondary heat source
5 ½" Sensor thimble for boiler sensor mandatory
6 EE (witn inflow absorber) 1½" Heating circuits forward flow according to hydraulic diagram
7 H (for immersion heater) 2" Elec. immersion heater (reduced to 1½") with extension
optional
8 1½" Secondary heat source return mandatory for secondary heat source
9 E (with inflow absorber) 1½" High-temp heating circuits return according to hydraulic diagram
10 E (with inflow absorber) 1½" Low-temp heating circuits return according to hydraulic diagram
11 6 mm Contact sensor sleeve for solar sensor mandatory
12 H (for immersion heater) 2" Elec. (reduziert auf 1½") with extension optional
13 1½" Low temp heating circuits return according to hydraulic diagram
15 6 mm Contact sensor sleeve for boiler thermometer optional
16 6 mm Contact sensor sleeve usually for boiler sensor according to hydraulic diagram
17 6 mm Contact sensor sleeve according to hydraulic diagram
18 6 mm Contact sensor sleeve according to hydraulic diagram
19 ½" Drain mandatory
22 F (flange) DN 200 Flange for finned heat exchanger optional
30a E (with inflow absorber) 1½" Corrugated connection pipe, possibly with priority flap
optional, only in combination with other tanks
30b E (with inflow absorber) 1½" Corrugated connection pipe, possibly with priority flap
31 E (with inflow absorber) 1½" Corrugated connection pipe
32 1½" Corrugated connection pipe
33 1½" Corrugated connection pipe
SLEEVE ASSIGNMENT
Tank size [l] Volumetric flow [m3 / h]
500 2.7
800 3.2
1000 3.4
1250 3.4
1500 4.0
2000 4.3
2500 4.4
3000 4.5
4000 4.9
5000 5.0
MAX. WATER FLOW RATE WITH PRO-HEAT TANK WITHOUT MIXING THE LAYERS
Note: The permissible total volumetric flow for each additional charged sleeve can be calculated as + 30% of the specified value per sleeve.
169
PRO-HEAT STRATIFIED TANKDIAGRAM 1
R
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
170
PRO-HEAT STRATIFIED TANKDIAGRAM 2
R
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
171
PRO-HEAT STRATIFIED TANKDIAGRAM 3
R
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
172
PRO-HEAT STRATIFIED TANKDIAGRAM 4
R
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
173
PRO-HEAT STRATIFIED TANKDIAGRAM 5
R
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
174
PRO-HEAT STRATIFIED TANKDIAGRAM 6
R
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
175
PRO-HEAT STRATIFIED TANKDIAGRAM 7
R
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
176
PRO-HEAT STRATIFIED TANKDIAGRAM 8
R
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
177
Spherical exchanger for solar stratified tank Pro-Clean® / 2WR / Pro-HeatThe spherical exchanger ensures optimum charging of the stratified tank. Includes an integrated copper finned tube heat exchanger.
General specificationsST 10 ST 20 ST 40 ST 60 ST 60K
Item no. 1620093 1620094 1620095 1620003 1620002Material Housing: S 235 JR/heat exchanger: CuInstallation Install via flange to Pro-Clean® and Pro-Heat tankHousingmax. operating pressure / max temp. 3 bar / 110 °CHeat exchangermax. operating pressure / max temp. 10 bar / 110 °CHeight without insulation 1457 mm 1927 mm 1457 mmDiameter without insulation 216 mm 300 mmTotal volume with heat exchanger 32 lt 67.5 lVolume of housing without heat exchanger 29.9 l 29.6 l 27.8 l 60 l
Volume of heat exchanger 2.1 l 2.4 l 4.2 l 7.5 l
Empty weight 40 kg 44 kg 50 kg 59 kg 61 kg
External dia. of heat exchanger 190 mm 257 mm
Length (insertion depth) of heat exchanger 570 mm 665 mm 850 mm 980 mm
Surface area of heat exchanger 2.63 m2 3.87 m2 5.5 m2 9.5 m2
Max. recommended collector surface area 10 m2 20 m2 40 m2 60 m2
STRATIFIED TANK ACCESSORIESSPHERICAL EXCHANGER
Volumetric flow [m3 / h]
Pres
sure
dro
p [b
ar]
Heat exchanger pressure drop (medium: water)
1) All size specifications have a tolerance range of +/- 3%
178
Finned tube heat exchanger performance curves
Output
Q [W] Output to be transferred
q [W/K] Output per 1 K temperature diªerence
t1 [°C] Heating water on entry
ts [°C] average tank temperature
V [m3/s] Hot water volumetric flow
w [m/s] Hot water velocity (shouldnot be greater than 1.8 m/s if possible)
Formulat for calculation: Q = f1 x q x (t1-ts)
0,2
1 2
0,4 0,6 0,8 1,0
t 1 (°C)
q (W
/K)
V (m3/h)
600
9070
60
500
400
300
200
100
0
WT-1,3 m2
w (m/s)
0,40 0,8 1,2 1,6 2,0
t 1 (°C)
q (W
/K)
700
600
500
400
300
200
100
WT-18
9070
60
0 1 2
V (m3/h)
w (m/s)
0,40 0,8 1,2 1,6 2,0
t 1 (°C)
q (W
/K)
700
600
500
400
300
200
100
WT-23
9070
50
0 1 2
V (m3/h)
w (m/s)
0,40 0,8 1,2 1,6 2,0
t 1 (°C)
q (W
/K)
700
600
500
400
300
200
100
ST 10
9070
50
0 1 2
V (m3/h)
w (m/s)
0 1 2 3 4
t 1 (°C)
q (W
/K)
300
400
500
600
700
800
900
1000WT-32
90
70
50
0 1 2
V (m3/h)
w (m/s)
0 1 2 3 4
t 1 (°C)
q (W
/K)
300
400
500
600
700
800
900
1000 ST 20
90
7050
0 1 2
V (m3/h)
w (m/s)
0 1 2 3 4
t 1 (°C)
q (W
/K)
300
400
500
600
700
800
900
1000WT-45
907050
0 1 2
V (m3/h)
w (m/s)
0,2
1 2
0,4 0,6 0,8 1,0
t 1 (°C)
q (W
/K)
V (m3/h)
600
9070
60
500
400
300
200
100
0
WT-1,3 m2
w (m/s)
0,40 0,8 1,2 1,6 2,0
t 1 (°C)
q (W
/K)
700
600
500
400
300
200
100
WT-18
9070
60
0 1 2
V (m3/h)
w (m/s)
0,40 0,8 1,2 1,6 2,0
t 1 (°C)
q (W
/K)
700
600
500
400
300
200
100
WT-23
9070
50
0 1 2
V (m3/h)
w (m/s)
0,40 0,8 1,2 1,6 2,0
t 1 (°C)
q (W
/K)
700
600
500
400
300
200
100
ST 10
9070
50
0 1 2
V (m3/h)
w (m/s)
0 1 2 3 4
t 1 (°C)
q (W
/K)
300
400
500
600
700
800
900
1000WT-32
90
70
50
0 1 2
V (m3/h)
w (m/s)
0 1 2 3 4
t 1 (°C)
q (W
/K)
300
400
500
600
700
800
900
1000 ST 20
90
7050
0 1 2
V (m3/h)
w (m/s)
0 1 2 3 4
t 1 (°C)
q (W
/K)
300
400
500
600
700
800
900
1000WT-45
907050
0 1 2
V (m3/h)
w (m/s)
0 1 2 3 4 51 2 3 4 51 2 3 4 5 6
t 1 (°C)
q (W
/K)
300300
400400
500500
600600
700
800
900
1000 ST 40
90
70
50
0 1 20 1 20 1 2
V (m3/h)3/h)3
w (m/s)
STRATIFIED TANK ACCESSORIESSPHERICAL EXCHANGER
f1 = Frost protection factor: 0.85 (for 40% antifreeze content)
179
No layer washers are installed in ST 60 and ST 60K.
Spherical exchanger connection setThe spherical exchanger set includes two pieces of flexible corrugated stainless-steel pipe. One end has a flat sealing thread (spherical ex-changer connection); the other has a tapered thread (solar connection). A corrugated hose that has been bent to the smallest bend radius may not be bent again. Two flat seals are provided for this connection.
Specifications
Type STAS 34 STAS 1 STAS 54
Art.Nr. 1610111 1610112 1610113
for spherical exchanger ST 10 / ST 20 ST 40 ST 60K / ST 60
Side A Flared union nut, female thread
Side A - Thread G ¾" G 1" G 1¼"
Side B Threaded nipple, male thread
Side B - Thread R ¾" R 1" R 1¼"
Corrugated hose two pieces Tuboflex stainless-steel corrugated hose W1.4571
Seals two pieces 24 x 20 x 2 two pieces 30 x 25 x 2 two pieces 38 x 32 x 2
Dimensions DN 20 x 425 DN 25 x 430 DN 32 x 445
STRATIFIED TANK ACCESSORIESSPHERICAL EXCHANGER INSTALLATION
SPHERICAL EXCHANGER CONNECTION SET
Sphe
rical
exc
hang
er
SealSealStainless washers
Pro-Clean® / Pro-Heat
180
Polyester fibre fleece insulation for Pro-Clean solar stratified tank® and Pro-HeatThe outer shell is made of hard synthetic polystyrene sheeting, which is 1 mm thick with a grey (RAL 9022) textured surface. The inner insulation shell is made of polyester fibre fleece. The three-part shell is assembled using adjustable clip locking rails. Includes lid and base insulat-ion as well as EPS sealing plugs. Entire insulation: Fire resistance class B2, contains no CFCs and is 100% recyclable.
STRATIFIED TANK ACCESSORIESPOLYESTER FIBRE FLEECE INSULATION 100 MM
Specifications
Property Test method Value Unit
Density - 27 kg/m3
Fogging behaviour DIN 75201 B 0.3 mg
Formaldehyde emission VDA 275 < 2 mg/kg
Fire test DIN 75200 < 100 mm/min
Fire resistance class DIN 4102 B1 -
Fire resistance class in a compound DIN 4102 B2 -
Continuous connection temperature - max. 130 °C
Colour - white -
Thermal conductivity coefficient of the insulation - 0.035 W/mK
DimensionsType ISOVS
PCH 500
ISOVS PCH 800
ISOVS PCH
1000B
ISOVS PCH
1000S
ISOVS PCH 1250
ISOVS PCH 1500
ISOVS PCH 2000
ISOVS PCH 2500
ISOVS PCH 3000
ISOVS PCH 4000
ISOVS PCH 5000
Item no. 1610834 1610835 1610836 1610837 1610838 1610839 1610840 1610841 1610842 1610843 1610844Dimension A 1020 mm 1105 mm 1180 mm 1140 mm 1235 mm 1320 mm 1400 mm 1600 mm 1540 mm 1840 mm 1840 mmDimension B 1175 mm 1280 mm 1380 mm 1320 mm 1440 mm 1540 mm 1640 mm 1840 mm 1800 mm 2140 mm 2140 mmThickness 100 mm 100 mm 100 mm 100 mm 100 mm 100 mm 100 mm 100 mm 110 mm 110 mm 10 mm
Polyester fibre fleece insulation for Pro-Clean solar stratified tank® and Pro-HeatThe outer shell is made of hard synthetic polystyrene sheeting, which is 1 mm thick with a grey (RAL 9022) textured surface. The inner insulation shell is made of polyester fibre fleece. The three-part shell is assembled using adjustable clip locking rails. Includes lid and base insulat-ion as well as EPS sealing plugs. Entire insulation: Fire resistance class B2, contains no CFCs and is 100% recyclable. Can only be used in combination with mounted spherical exchanger!
Dimensions
Property Test Methode Wert Einheit
Density - 12 kg/m3
Fogging behaviour DIN 75201 B 0,2 mg
Formaldehyde emission VDA 275 < 2 mg/kg
Fire test DIN 75200 < 100 mm/min
Fire resistance class DIN 4102 B1 -
Fire resistance class in a compound DIN 4102 B2 -
Continuous connection temperature - max. 130 °C
Colour - weiss -
Thermal conductivity coefficient of the insulation - 0,041 W/mK
POLYESTERFASERVLIES-ISOLIERUNG 200 MM
DimensionsType ISOVL 200
PCH 800ISOVL 200 PCH 1000S
Item no. 1610793 1610794Dimension A 1524 mm 1558 mmDimension B 1154 mm 1201 mmHeight 2110 mm 2320 mmThickness 200 mm 200 mm
A
B
181
Polyester fibre fleece insulation for PRO-CLEAN® 2WR solar stratified tankThe outer shell is made of hard synthetic polystyrene film, which is 1 mm thick with a grey (RAL 9022) textured surface. The inner insulation shell is made of polyester fibre fleece. The three-part shell is assembled using adjustable clip locking rails. Includes lid and base insulat-ion as well as EPS sealing plugs. Entire insulation: Fire resistance class B2, contains no CFCs and is 100% recyclable.
STRATIFIED TANK ACCESSORIESPOLYESTER FIBRE FLEECE INSULATION FOR PRO-CLEAN® 2WR
Specifications
Property Test method Value Unit
Density - 27 kg/m3
Fogging behaviour DIN 75201 B 0.3 mg
Formaldehyde emission VDA 275 < 2 mg/kg
Fire test DIN 75200 < 100 mm/min
Fire resistance class DIN 4102 B1 -
Fire resistance class in a compound DIN 4102 B2 -
Continuous connection temperature - max. 130 °C
Colour - white -
Thermal conductivity coefficient of the insulation - 0.035 W/mK
AbmessungenType ISOVS
PC 2W 1250ISOVS
PC 2W 1500ISOVS
PC 2W 2000ISOV
PC 2W 2500ISOVS
PC 2W 3000ISOVS
PC 2W 4000ISOVS
PC 2W 5000
Item no. 1610845 1610846 1610847 1610848 1610849 1610850 1610884Dimension A 1235 mm 1320 mm 1400 mm 1600 mm 1540 mm 1840 mm 1840 mmDimension B 1440 mm 1540 mm 1640 mm 1840 mm 1800 mm 2140 mm 2140 mmThickness 100 mm 100 mm 100 mm 100 mm 110 mm 110 mm 110 mm
182
FS/1R fresh water tankSimple, multi-functional storage system for domestic hot water and heating with a solar exchanger for solar charging and integrated hygienic water heating using a continuous heating process with a corrugated stainless-steel pipe. Includes facili-ties to mount solar station and solar expansion tank on the tank.
Area of use• In solar systems, water heating and backup heating with solar charging
Product advantages• Simple utilisation of solar energy for hot water and heating• Germ-free fresh water heating using a special corrugated stainless-steel pipe• Space-saving design • Secondary heat source with all traditional heating systems
FS/2R fresh water tankSimple multi-functional solar tank system for domestic hot water and heating with two solar exchangers for solar charging. As with FS/1R, hygienic continuous flow water heating with a corrugated stainless-steel pipe is integrated. Facilities to mount the solar station and solar expansion tank on the tank are not included in the design.
Area of use• In solar systems, water heating and backup heating with solar charging
Product advantages• Simple utilisation of solar energy for hot water and heating• Solar priority circuit for faster water heating• Germ-free fresh water heating using a special corrugated stainless-steel pipe• Space-saving design • Secondary heat source with all traditional heating systems
PRODUCT DESCRIPTION
FS FRESH WATER TANK
183
FS/1R fresh water tankSimple, multi-functional storage system for domestic hot water and heating with a solar exchanger for solar charging and integrated hygienic water heating using a continuous heating process with a corrugated stainless-steel pipe. Includes facili-ties to mount solar station and solar expansion tank on the tank.
Area of use• In solar systems, water heating and backup heating with solar charging
Product advantages• Simple utilisation of solar energy for hot water and heating• Germ-free fresh water heating using a special corrugated stainless-steel pipe• Space-saving design• Secondary heat source with all traditional heating systems
Specifications
Max. operating pressure 3 barMax. temperature 110 °C
MaterialS 235 JR; Metal plate wall thickness 3 mm, black
Installation Stand ringWelded joint design DIN 4753 Part 3Production DIN 4753 Part 1
Specifications
Type FS 375/1R FS 500/1R FS 800/1R FS 1000-S/1R
Item no. 1610603 1610303 1610304 1610305
Height without insulation 1675 mm 1790 mm 1940 mm 2150 mm
Height with insulation 1725 mm 1860 mm 2010 mm 2220 mmDiameterwithout insulation 550 mm 650 mm 750 mm 790 mm
Diameterwith insulation 710 mm 850 mm 950 mm 990 mm
Tilt height 1695 mm 1820 mm 1975 mm 2185 mm
Weight with register 142 kg 200 kg 235 kg 270 kgTotal volumewith register and corrugated HW pipe
361 l 530 l 760 l 950 l
Total volume without register and corrugated HW pipe
355 l 509 l 746 l 932 l
FS/1R PRODUCT DESCRIPTION
FS/1R FRESH WATER TANK
1) All size specifications are in a tolerance range of +/- 3%
184
Corrugated pipe
Type FS 375/1R FS 500/1R FS 800/1R FS 1000-S/1R
Material Stainless-steel corrugated hose DIN 1.4404 (AISI 316L, V4A)Max. operating pressure 6 barLength 15 m 20 m 25 mSurface area (Corrugated pipe = 0.258 m2/m) 3.87 m2 5.16 m2 6.45 m2
Volume 26 l 35 l 45 l
Figures quoted with a tolerance of 5%
Solar register
Type FS 375/1R FS 500/1R FS 800/1R FS 1000-S/1R
Material Steel
External diameter 33.7 mm
Internal diameter 29.1 mm
Wall thickness 2.3 mm
Length 15 m 17 m 21 m 27 m
Windings (number) 10 15 15 16
Total height 450 mm 500 mm 620 mm 610 mmAverage diameter of the windings
460 mm 560 mm 660 mm 700 mm
Surface area (smooth pipe) 1.5 m2 1.8 m2 2.2 m2 2.8 m2
Volume 10 l 11.31 l 13.97 l 17.96 l
Max. collector surface area 10 m2 10.5 m2 13 m2 15.5 m2
FS/1R SPECIFICATIONS
FS/1R FRESH WATER TANK
020406080100120140160180200220240260280300320340360380400
0,13 0,19 0,26 0,32 0,39 0,45 0,52 0,58 0,65 0,71 0,78 0,84 0,91 0,97 1,03
0,6 0,9 1,2 1,5 1,8 2,1 2,4 2,7 3 3,3 3,6 3,9 4,2 4,5 4,8
10 15 20 25 30 35 40 45 50 55 60 65 70 75 80
Pressure drop of corrugated pipe DN 40
Tap quantity and flow velocity
Volume flow [m3/h]
Flow velocity [m/s]Tap quantity[m3/h]Tap quantity[l/min]
Pres
sure
dro
p in
mba
rPr
essu
re d
rop
in m
bar
Flow velocity < 0.7 m/s
FS/1R 375 solar registerFS/1R 500 solar registerFS/1R 800 solar register FS/1R 1000-S solar register
FS 800 / FS 1000-SFS 500FS 375
FS/1R solar register water tank pressure drop curve
0
20
40
60
80
100
120
140
160
180
200
220
240
260
0,25 0,5 0,75 1 1,25 1,5 1,75 2 2,25 2,5 2,75 3
185
FS/1R FRESH WATER TANK
SpecificationsFS-1R Tank size
375 500 800 1000-S
Discharge amounts and HW tap quantities (+/- 5% deviation)
Single discharge capacity (warm water up to 38 °C) when the backup tank is charged to 60 °C litres 270 380 540 700
Single discharge capacity (warm water up to 38 °C) when the backup tank is charged to 55 °C litres 216 304 432 560
Single discharge capacity (warm water up to 38 °C) when the backup tank is charged to 50°C litres 186 262 372 483
Temperature difference between semi-charged backup tank and hot water with an HW tap quantity of
30 l/min °C 7 6 540 l/min °C 9 8 750 l/min °C 16 14 12
FS/1R DIMENSIONS AND SLEEVE ASSIGNMENT
FS/1R PERFORMANCE DATA
Rp 3/4 " closed sleeve
*
* Only for FS 1000 S
Dr. no.: domestic hot water connection
Dr. no.: domestic hot water connection
Section A-A
Section B-B
Part 1
Tilt
heig
ht
Part 3
Part 2
s4
s1
s2
s1
s3
s4 s1
s4
186
FS/1R FRESH WATER TANK
FS 375/1R FS 500/1R FS 800/1R FS 1000-S/1R
a 1645 mm 1760 mm 1910 mm 2120 mm
b 1550 mm 1650 mm 1780 mm 1990 mm
c 1220 mm 1270 mm 1450 mm 1530 mm
d 1110 mm 1160 mm 1340 mm 1420 mm
e 1000 mm 1050 mm 1200 mm 1300 mm
f 890 mm 940 mm 1060 mm 1160 mm
g 780 mm 830 mm 920 mm 1000 mm
h 590 mm 640 mm 660 mm 710 mm
i 340 mm 340 mm 370 mm 380 mm
j 260 mm 260 mm 280 mm 280 mm
k 240 mm 240 mm 260 mm 265 mm
l 330 mm 380 mm 380 mm 380 mm
m 430 mm 480 mm 500 mm 500 mm
n 660 mm 710 mm 730 mm 780 mm
o 860 mm 910 mm 1040 mm 1140 mm
p 1030 mm 1080 mm 1230 mm 1235 mm
q 1110 mm 1160 mm 1340 mm 1420 mm
r 1300 mm 1350 mm 1500 mm 1610 mm
s 1470 mm 1570 mm 1690 mm 1900 mm
Sleeve assignmentNo. Designation Dimensions Use Comment
2 V4A Rp 1" HW-connection (stainless-steel) mandatory (poss. with circulation lance)3 – Rp ½" Exhaust pipe mandatory4 – Rp 1½" Secondary heat source according to the hydraulic diagram5 – Di 6 mm Sensor sleeve mandatory6 – Rp 1½" Secondary heat source according to the hydraulic diagram7 H Rp 2" Electric immersion heater with extension optional8 – Rp 1½" Secondary heat source according to the hydraulic diagram9 – Rp 1½" Secondary heat source according to the hydraulic diagram
10 – Rp 1½" Secondary heat source according to the hydraulic diagram11 – Di 6 mm Solar sensor sleeve mandatory12 – Rp 1½" Secondary heat source optional13 V4A Rp 1" CW-connection (stainless-steel) mandatory15 – Rp ½" Sensor thimble for boiler thermometer optional16 – Di 6 mm Sensor sleeve according to the hydraulic diagram17 – Di 6 mm Sensor sleeve according to the hydraulic diagram18 – Di 6 mm Sensor sleeve according to the hydraulic diagram19 – Di 6 mm Sensor sleeve according to the hydraulic diagram20 – Rp ½" Drain mandatory21 – M6 Mounting sleeve for solar expansion tank mandatory22 – M6 Mounting sleeve for solar station mandatory23 – M6 Mounting sleeve for solar station mandatory24 – G1" Solar station connection, solar forward flow (hot) mandatory25 – G1" Solar station connection, solar return flow (cold) mandatory
30a – Rp 1½" Corrugated connection pipe
optional, only in combinationwith other tanks
30b – Rp 1½" Corrugated connection pipe31 – Rp 1½" Corrugated connection pipe32 – Rp 1½" Corrugated connection pipe33 – Rp 1½" Corrugated connection pipe
FS 375/1R FS 500/1R FS 800/1R FS 1000-S/1R
t 1550 mm 1650 mm 1780 mm 1990 mm
u1 1540 mm 1540 mm 1680 mm 1900 mm
u2 – – – 1680 mm
v 1150 mm 1150 mm 1170 mm 1170 mm
w 720 mm 720 mm 725 mm 725 mm
x 270 mm 270 mm 350 mm 350 mm
y 820 mm 870 mm 1020 mm 1020 mm
z 1280 mm 1330 mm 1480 mm 1480 mm
h1 200 mm 210 mm 230 mm 230 mm
h2 1300 mm 1390 mm 1500 mm 1710 mm
h3 145 mm 160 mm 180 mm 180 mm
s1 80 mm 100 mm 100 mm 100 mm
s2 95 mm 115 mm 115 mm 115 mm
s3 105 mm 125 mm 125 mm 125 mm
s4 40 mm 50 mm 50 mm 50 mm
D1 550 mm 600 mm 600 mm 740 mm
D2 710 mm 650 mm 750 mm 790 mm
Tilt height 1695 mm 1820 mm 1975 mm 2185 mm
FS fresh water tank table with dimensions as per illustrations
FS/1R TABLE OF DIMENSIONS AND SLEEVE ASSIGNMENT
187
FS/1R FRESH WATER TANKDIAGRAM 1
RR
RR
RR
R
R
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
188
FS/1R FRESH WATER TANKDIAGRAM 2
RR
RR
RR
R
R
38-6
5°C
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
189
FS/1R FRESH WATER TANKDIAGRAM 3
RR
RR
RR
R
R
38-6
5°C
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
190
FS/1R FRESH WATER TANKDIAGRAM 4
RR
RR
RR
R
R
38-6
5°C
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
191
FS/1R FRESH WATER TANKDIAGRAM 5
RR
RR
RR
R
R
38-6
5°C
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
192
FS/1R FRESH WATER TANKDIAGRAM 6
RR
RR
RR
R
R
38-6
5°C
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
193
FS/1R FRESH WATER TANKDIAGRAM 7
RR
RR
RR
R
R
38-6
5°C
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
194
FS/1R FRESH WATER TANKDIAGRAM 8
RR
RR
RR
R
R
38-6
5°C
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
195
FS/2R fresh water tankSimple multi-functional solar tank system for domestic hot water and heating with two solar exchangers for solar charging. As with FS/1R, hygienic continuous flow water heating with a corrugated stainless-steel pipe is integrated. Facilities to mount the solar station and solar expansion tank on the tank are not included in the design.
Area of use• In solar systems, water heating and backup heating with solar charging
Product advantages• Simple utilisation of solar energy for hot water and heating• Solar priority circuit for faster water heating• Germ-free fresh water heating using a special corrugated stainless-steel pipe• Space-saving design • Secondary heat source with all traditional heating systems
Technical description
Max. operating pressure 3 barMax. temperature 110°C
MaterialS 235 JR;Metal plate wall thickness 3 mm, black
Installation Stand ringWelded joint design DIN 4753 Part 3Production DIN 4753 Part 1
FS/2R PRODUCT DESCRIPTION
FS/2R FRESH WATER TANK
1) All size specifications are in a tolerance range of +/- 3%
Specifications
Type FS 500/2R FS 800/2R FS 1000S/2R FS 1250/2R FS 1500/2R FS 2000/2R
Item no. 1610692 1610288 1610289 1610783 1610784 1610785
Height without insulation 1.760 mm 1940 mm 2120 mm 2.200 mm 2.190 mm 2.280mm
Height with insulation 1.860 mm 2010 mm 2220 mm 2.300 mm 2.290 mm 2.380 mm
Diameterwithout insulation 650 mm 750 mm 790 mm 900 mm 1.000 mm 1.100 mm
Diameterwith insulation 850 mm 950 mm 990 mm 1.100 mm 1.200 mm 1.300 mm
Tilt height 1.820 mm 1975 mm 2185 mm 2.270 mm 2.275 mm 2.380 mm
Weigh 220 kg 240 kg 280 kg 370 kg 420 kg 480 kg
Total volumeWith register and corrugated HW pipe
520 lt 760 lt 980 lt 1250 lt 1490 lt 1930 lt
Total volume Without register and corrugated HW pipe
460 lt 681 lt 894 lt 1160 lt 1383 lt 1872 lt
196
FS/2R SPECIFICATIONS
FS/2R FRESH WATER TANK
0
20
40
60
80
100
120
1 2 3 4 5 6 7 8
020406080100120140160180200220240260280300320340360380400
0,13 0,19 0,26 0,32 0,39 0,45 0,52 0,58 0,65 0,71 0,78 0,84 0,91 0,97 1,03
0,6 0,9 1,2 1,5 1,8 2,1 2,4 2,7 3 3,3 3,6 3,9 4,2 4,5 4,8
10 15 20 25 30 35 40 45 50 55 60 65 70 75 80
Upper / Lower solar registerType FS 500/2R FS 800/2R FS 1000S/2R FS 1250/2R FS 1500/2R FS 2000/2RMaterial SteelExternal diameter 33,7 mmInternal diameter 29,1 mmWall thickness 2,3 mmLength 1,2 / 1,8 m² 1,5 / 2,2 m² 1,9 / 2,8 m² 2,1 / 3,2 m² 2,4 / 3,6 m² 2,8 / 4,0 m²Windings (number) 11 / 17m 15 / 22m 18 / 27m 20 / 30m 23 / 34m 26 / 38mTotal height 6 / 10 7 / 10 9 / 12 8 / 12 8 / 12 8 / 12Average diameter of the windings 300 / 400mm 350 / 500mm 450 / 600mm 400 / 600mm 400 / 600mm 400 / 600mmSurface area (smooth pipe) 560 mm 660 mm 700 mm 810 mm 910 mm 1010 mmVolume 10 / 15,5 lt 13,7 / 20 lt. 16,5 / 24,5 lt 18 / 27,5 lt 21 / 31 lt 23,7 / 34,7 ltMax. collector surface area 10,5 m² 13 m² 15,5 m² 18 m² 21 m² 25,5 m²
Corrugated pipeType FS 500/2R FS 800/2R FS 1000S/2R FS 1250/2R FS 1500/2R FS 2000/2R
Material Stainless-steel corrugated hose DIN 1.4404 (AISI 316L, V4A)Max. operating pressure 6 barLength 20 m 25 m 25 m 25 m 30 m 35 mSurface area (Corrugated pipe = 0.258 m2/m) 5,16 m² 6,45 m² 6,45 m² 6,45 m² 7,74 m² 9,03 m²
Volume 35 lt 45 lt 45 lt 45 lt 55 lt 60 ltFigures quoted with a tolerance of 5%
Pressure drop of corrugated pipe DN 40
Tap quantity and flow velocity
Volume flow [m3/h]
Flow velocity [m/s]Tap quantity[m3/h]Tap quantity[l/min]
Pres
sure
dro
p in
[mba
r]Pr
essu
re d
rop
in [m
bar]
Flow velocity < 0.7 m/s
FS/2R 2000 solar register
FS/2R 1500 solar register
FS/2R 1250 solar register
FS/2R 1000S solar register
FS/2R 800 solar register
FS/2R 500 solar register
FS/2R 2000 secondary heat source register
FS/2R 1500 secondary heat source register
FS/2R 1250 secondary heat source register
FS/2R 1000S secondary heat source register
FS/2R 800 secondary heat source register
FS/2R 500 secondary heat source register
FS/2R 2000
FS/2R 1500
FS/2R 800/1000/1250
FS/2R 500
Pressure drop curve for solar and secondary heat source registers on the FS/2R water tank
1) All size specifications are in a tolerance range of +/- 3%
197
FS/2R FRESH WATER TANKFS/2R DIMENSIONS AND SLEEVE ASSIGNMENT
FS/2R PERFORMANCE DATA
Rp 3/4 ” closed sleeve
*
* Only for FS 1000-S
Dr. no.: domestic hot water connection
Dr. no.: domestic hot water connection
Section A-A
Section B-B
Part 1
Tilt
heig
ht
Part 3
Part 2
s3s3
s3
s3
SpecificationsTank size FS-2R
500 800 1000S 1250 1500 2000Discharge amounts and HW tap quantities (+/- 5% deviation)Single discharge capacity (warm water up to 38 °C) when the backup tank is charged to 60 °C litres 380 540 700 900 1050 1360
Single discharge capacity (warm water up to 38 °C) when the backup tank is charged to 55 °C litres 304 432 560 720 843 1090
Single discharge capacity (warm water up to 38 °C) when the backup tank is charged to 50 °C litres 262 372 483 620 727 940
Temperature difference between a semi-charged backup tank and hot water with an HW tap quantity of
30 l/min °C 6 5 4 340 l/min °C 8 7 6 550 l/min °C 14 12 10 8
198
FS/2R FRESH WATER TANK
Sleeve assignment
No. Designation Dimensions Use Comment
2 V4A Rp 1" HW-connection (stainless-steel) mandatory (poss. with circulation lance)3 – Rp ½" Exhaust pipe mandatory4 – Rp 1½" Secondary heat source according to the hydraulic diagram5 – Di 6 mm Sensor sleeve mandatory6 – Rp 1½" Secondary heat source according to the hydraulic diagram7 H Rp 2" Electric immersion heater with extension optional8 – Rp 1½" Secondary heat source according to the hydraulic diagram9 – Rp 1½" Secondary heat source according to the hydraulic diagram
10 – Rp 1½" Secondary heat source according to the hydraulic diagram11 – Di 6 mm Solar sensor sleeve mandatory12 – Rp 1½" Secondary heat source optional13 V4A 1" CW-connection (stainless-steel) mandatory15 – Rp ½" Sensor thimble for boiler thermometer optional16 – Di 6 mm Sensor sleeve according to the hydraulic diagram17 – Di 6 mm Sensor sleeve according to the hydraulic diagram18 – Di 6 mm Sensor sleeve according to the hydraulic diagram19 – Di 6 mm Sensor sleeve according to the hydraulic diagram20 – Rp ½" Drain mandatory21 – Di 6 mm Sensor sleeve according to the hydraulic diagram22 – G 1" Solar station connection, solar forward flow (hot) mandatory23 – G 1" Solar station connection, solar return flow (cold) mandatory24 – G 1" Solar station connection, solar forward flow (hot) mandatory25 – G 1" Solar station connection, solar return flow (cold) mandatory
30a – Rp 1½" Corrugated connection pipe
optional, only in combination with other tanks
30b – Rp 1½" Corrugated connection pipe31 – Rp 1½" Corrugated connection pipe32 – Rp 1½" Corrugated connection pipe33 – Rp 1½" Corrugated connection pipe
FS 800/2R FS 1000S/2R
s 1690 mm 1900 mmt 1780 mm 1990 mm
u1 1680 mm 1900 mmu2 – 1680 mm
v 1170 mm 1170 mmw 725 mm 725 mmx 350 mm 350 mm
y1 270 mm 270 mmy2 770 mm 870 mmz1 1275 mm 1350 mmz2 1625 mm 1800 mms1 100 mm 100 mms2 115 mm 115 mms3 50 mm 50 mmD1 600 mm 740 mmD2 750 mm 790 mmTilt
height 1975 mm 2185 mm
FS 800/2R FS 1000S/2R
a 1910 mm 2120 mmb 1780 mm 1990 mmc 1450 mm 1530 mmd 1340 mm 1420 mme 1200 mm 1300 mmf 1060 mm 1160 mmg 920 mm 1000 mmh 660 mm 710 mmi 370 mm 380 mmj 280 mm 280 mmk 260 mm 265 mml 380 mm 380 mm
m 500 mm 500 mmn 730 mm 780 mmo 1040 mm 1140 mmp 1340 mm 1240 mmq 1500 mm 1610 mmr 1600 mm 1790 mm
FS fresh water tank table with dimensions as per illustrations
FS/2R TABLE OF DIMENSIONS AND SLEEVE ASSIGNMENT
199
FS/2R FRESH WATER TANKFS/2R DIAGRAM
R
38-6
5°C
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
200
FS/2R TABLE OF DIMENSIONS AND SLEEVE ASSIGNMENT
FS/1R + 2R ACCESSORIES
Polyester fibre fleece insulation for fresh water tanksThe outer shell is made of hard synthetic polystyrene film, which is 1 mm thick with a grey (RAL 9022) textured surface. The inner insulation shell is made of polyester fibre fleece. The three-part shell is assembled using adjustable clip locking rails. Including lid and base insulation as well as EPS sealing plugs. Entire insulation: Fire resistance class B2, contains no CFCs and is 100% recyclable.
DimensionsType ISOVL-FS
375/1RISOVL-FS
500/1RISOVL-FS
800/1RISOVL-FS 1000S/1R
Item no. 1610552 1610553 1610554 1610555Diameter 710 mm 850 mm 950 mm 990 mmThickness 80 mm 100 mm 100 mm 100 mm
POLYESTER FIBRE FLEECE INSULATION
POLYESTER FIBRE FLEECE INSULATION FOR FS/1R FRESH WATER TANK
POLYESTER FIBRE FLEECE INSULATION FOR FS/2R FRESH WATER TANK
Specifications
Property Test method Value Units
Density - 12 kg/m
Fogging behaviour DIN 75201 B < 0.2 mg
Formaldehyde Emission VDA 275 < 2 mg/kg
Fire test DIN 75200 < 100 mm/min
Fire resistance class DIN 4102 B2 -
Fire resistance class in a compound DIN 4102 B2 -
Continuous connection temperature - max. 130 °C
Colour - white -
Thermal conductivity of the insulation - 0.041 W/mK
AbmessungenType ISOVL-FS
500/2RISOVL-FS
800/2RISOVL-FS1000S/2R
ISOVL-FS1250/2R
ISOVL-FS1500/2R
ISOVL-FS2000/2R
Item no. 1610742 1610556 1610557 1610795 1610796 1610800Diameter 850 mm 950 mm 990 mm 1100 mm 1200 mm 1300 mmThickness 100 mm 100 mm 100 mm 100 mm 100 mm 100 mm
201
Specifications
Type WT 5
Item no. 1620012Headpiece Material: AISI 303; hex head screw spanner size 34; female thread: Rp ½”; thread depth: 23 mm;
male thread: R 1”; thread length: 15 mmCorrugated stainless-steel pipe Material: AISI 316L, DN 18
Can be used for circulation losses up to 5 kW (see performance data).
The threaded connections have to be sealed properly (hemp, sealing compound, ...).
Hot water pipe
1200 mm
Rp 1
/2 ”
R1 ”
ø 18
Hex
head
scr
ew, s
pann
er s
ize 3
4
HW sleevePro-Clean® Coupling Branch connector Circulation pipe PC-WT5
Hot watercirculation pipe
Circulation lanceA circulation lance for preheating hot water is used in tanks with up to 5 kW circulation loss. A lance is mounted directly to the hot water connection of the tank.
WT 5 CIRCULATION LANCE
STRATIFIED TANK/FS ACCESSORIES
202
STRATIFIED TANK/FS ACCESSORIES
Hot water circulation performance of Pro-Clean® 1000 l
Circ. for-ward flow
[°C]
Circ. return flow [°C]
Flow in circu-lation system
[l/h]
Performance [W]
Pressure drop
p [mbar]
50 °C1)
38.6 32.1 500 3770 35039.2 33.1 400 2828 30040.0 32.7 300 2538 24040.4 31.9 200 1972 20040.5 30.5 100 1160 110
55 °C1)
41.4 33.1 500 4814 35041.6 33.4 400 3799 30042.5 32.5 300 3480 24042.8 32.0 200 2501 20042.9 31.8 100 1283 110
60 °C1)
42.7 32.5 500 5873 35043.2 33.4 400 4858 30045.7 34.0 300 3741 24046.5 33.8 200 2944 20046.8 33.0 100 1595 110
1) Upper tank temperature.
020406080100120140160180200220240260280300320340360
0,23 0,46 0,69 0,92 1,15
0,1 0,2 0,3 0,4 0,5
84,68,42,36,1
Small circulation with circulation losses up to 5 kW using a circulation lance.
Kollektorfühler Sonnenkollektor
Solarstation
Spül
vent
ile
EX
T
P
TSKB
[Entlüfter]
DUPLEX
od. Thermostat
SolarfühlerFilter
Schwimmbad
PWT SB-Fühler
max. 2° delta T
M
M
Radiatoren FBH
M
Kessel min. 48°CKesselfühler im Speicher
alle Anfahrentlastungen "Ein"
gesteuert über Brennerausgang Speicherladepumpe
mit Pumpennachlauf
WW
38°-65°CTh
ÖlPellets
Gas
Verrohrung in temperaturbeständiger Ausführung
Nachheizung
KW
Schwimmbadtechnik bauseits!
Solarfühler
EX
13
10
9
8
76
4
2
Sphä
rent
ausc
her
FE-Hahn
PRO CLEAN
15
5
16
17
18
11
19
3
Boilerfühler
KW
12
Kollektorfühler Sonnenkollektor
Solarstation
EX
T
P
TSKB
[Entlüfter]
Simplex
M
Radiatoren FBH
M
Kessel min. 48°CKesselfühler im Speicher
alle Anfahrentlastungen "Ein"
gesteuert über Brennerausgang Speicherladepumpe
mit Pumpennachlauf
Solarfühler
EX
13
10
9
8
76
4
2
Sphä
rent
ausc
her
WW
PRO CLEAN
38°-65°CTh
ÖlGas
15
5
16
17
18
11
19
3
Boilerfühler
Kesselfühler
PSN
FE-Hahn
KW
KW
31
32
33
30
12
Spül
vent
ile
FE-Hahn
PSN
FE-Hahn
Kesselfühler
Pellets
Kollektorfühler Sonnenkollektor
Solarstation
EX
T
P
TSKB
[Entlüfter]
Simplex
M
Radiatoren FBH
M
Kessel min. 48°CKesselfühler im Speicher
alle Anfahrentlastungen "Ein"
gesteuert über Brennerausgang Speicherladepumpe
mit Pumpennachlauf
Solarfühler
EX
13
10
9
8
76
4
2
Sphä
rent
ausc
her
WW
PRO CLEAN
38°-65°CTh
ÖlPellets
Gas
15
5
16
17
18
11
19
Boilerfühler
Kesselfühler
PSN
KW
KW
31
32
33
30
12
Spül
vent
ile
Kollektorfühler Sonnenkollektor
Solarstation
EX
T
P
TSKB
[Entlüfter]
Simplex
M
Radiatoren FBH
M
Kessel min. 48°CKesselfühler im Speicher
alle Anfahrentlastungen "Ein"
gesteuert über Brennerausgang Speicherladepumpe
mit Pumpennachlauf
Solarfühler
EX
13
10
9
8
76
4
2
Sphä
rent
ausc
her
PRO CLEAN
38°-65°CTh
ÖlPellets
Gas
15
5
16
17
18
11
19
Boilerfühler
Tichelmannsystem!
KW
KW
31
32
33
30
12
Spül
vent
ile
3FE-Hahn FE-Hahn
13
10
9
8
7
6
4
2
PRO CLEAN
15
5
16
17
18
11
19
31
32
33
30
12
3FE-Hahn
3FE-Hahn
Kesselfühler
Rückschlagklappe
Umwälzpumpe Absperrventil
Dreiwegventil
Fühler
Thermo-, Manometer
Sicherheitsventil M
ZirkulationKaltwasserWarmwasser
Heizungsrücklauf
Heizungsvorlauf
Solar-RL
Solar-VL
Steuerung
Verbindungswellrohr Vorrangklappe
Th
38°-65°C
Brauchwasser-Mischventil
Rückschlagklappe
Umwälzpumpe Absperrventil
Dreiwegventil
Fühler
Thermo-, Manometer
Sicherheitsventil M
ZirkulationKaltwasserWarmwasser
Heizungsrücklauf
Heizungsvorlauf
Solar-RL
Solar-VL
Steuerung
Verbindungswellrohr Vorrangklappe
Th
38°-65°C
Brauchwasser-Mischventil
Rückschlagklappe
Umwälzpumpe Absperrventil
Dreiwegventil
Fühler
Thermo-, Manometer
Sicherheitsventil M
ZirkulationKaltwasserWarmwasser
Heizungsrücklauf
Heizungsvorlauf
Solar-RL
Solar-VL
Steuerung
Verbindungswellrohr Vorrangklappe
Th
38°-65°C
Brauchwasser-Mischventil
Rückschlagklappe
Umwälzpumpe Absperrventil
Dreiwegventil
Fühler
Thermo-, Manometer
Sicherheitsventil M
ZirkulationKaltwasserWarmwasser
Heizungsrücklauf
Heizungsvorlauf
Solar-RL
Solar-VL
Steuerung
Verbindungswellrohr Vorrangklappe
Th
38°-65°C
Brauchwasser-Mischventil
Kollektorfühler Sonnenkollektor
Solarstation
Spül
vent
ile
EX
T
P
TSKB
[Entlüfter]
DUPLEX
M
Radiatoren FBH
M
Kessel min. 48°CKesselfühler im Speicher
alle Anfahrentlastungen "Ein"
gesteuert über Brennerausgang Speicherpumpe
mit Pumpennachlauf
WW
38°-65°CTh
ÖlPellets
Gas
KW
Solarfühler
EX
13
10
9
8
76
4
2
Sphä
rent
ausc
her
FE-Hahn
PRO CLEAN
15
5
16
17
18
11
19
3
Boilerfühler
12
Kesselfühler
Rückschlagklappe
Umwälzpumpe Absperrventil
Dreiwegventil
Fühler
Thermo-, Manometer
Sicherheitsventil M
ZirkulationKaltwasserWarmwasser
Heizungsrücklauf
Heizungsvorlauf
Solar-RL
Solar-VL
Steuerung
Verbindungswellrohr Vorrangklappe
Th
38°-65°C
Brauchwasser-Mischventil
Boiler Bestand
M
KWSolarfühler
Kollektorfühler Sonnenkollektor
Solarstation
Spül
vent
ile
EX
T
P
TSKB
[Entlüfter]
Simplex
WW
38°-65°CTh
ÖlPellets
Gas
KW
Solarfühler
EX
13
10
9
8
76
4
2
Sphä
rent
ausc
her
FE-Hahn
PRO CLEAN
15
5
16
17
18
11
19
3
Boilerfühler
12
Rückschlagklappe
Umwälzpumpe Absperrventil
Dreiwegventil
Fühler
Thermo-, Manometer
Sicherheitsventil M
ZirkulationKaltwasserWarmwasser
Heizungsrücklauf
Heizungsvorlauf
Solar-RL
Solar-VL
Steuerung
Verbindungswellrohr Vorrangklappe
Th
38°-65°C
Brauchwasser-Mischventil
KW
M
Kollektorfühler Sonnenkollektor
Solarstation
Spül
vent
ile
EX
T
P
TSKB
[Entlüfter]
M
Radiatoren FBH
M
Kessel min. 48°CKesselfühler im Speicher
alle Anfahrentlastungen "Ein"
gesteuert über Brennerausgang Speicherladepumpe
mit Pumpennachlauf
38°-65°CTh
ÖlPellets
Gas
KW
Solarfühler
EX
13
10
9
8
76
4
2
Sphä
rent
ausc
her
FE-Hahn
PRO CLEAN
15
5
16
17
18
11
19
3
Boilerfühler
KW
12
Kesselfühler
Kollektorfühler Sonnenkollektor
Solarstation
Spül
vent
ile
EX
T
P
TSKB
[Entlüfter]
Simplex
WW
38°-65°CTh
ÖlPellets
Gas
KW
Solarfühler
EX
13
10
9
8
76
4
2
Sphä
rent
ausc
her
FE-Hahn
PRO CLEAN
15
5
16
17
18
11
19
3
Boilerfühler
12
Rückschlagklappe
Umwälzpumpe Absperrventil
Dreiwegventil
Fühler
Thermo-, Manometer
Sicherheitsventil M
ZirkulationKaltwasserWarmwasser
Heizungsrücklauf
Heizungsvorlauf
Solar-RL
Solar-VL
Steuerung
Verbindungswellrohr Vorrangklappe
Th
38°-65°C
Brauchwasser-Mischventil
KW
M
FBH
Kollektorfühler Sonnenkollektor
Solarstation
Spül
vent
ile
EX
T
P
TSKB
[Entlüfter]
Simplex
WW
38°-65°CTh
KW
Solarfühler
EX
13
10
9
8
76
4
2
Sphä
rent
ausc
her
FE-Hahn
PRO CLEAN
15
5
16
17
18
11
19
3
Boilerfühler
12
Rückschlagklappe
Umwälzpumpe Absperrventil
Dreiwegventil
Fühler
Thermo-, Manometer
Sicherheitsventil M
ZirkulationKaltwasserWarmwasser
Heizungsrücklauf
Heizungsvorlauf
Solar-RL
Solar-VL
Steuerung
Verbindungswellrohr Vorrangklappe
Th
38°-65°C
Brauchwasser-Mischventil
KW
M
Radiatoren
Fühler Diff. Steuerung
M
Empfehlenswert bei RL Temp.über 30°C
Fühler Diff.
Schema Nr.: PC_09/07 Schema Nr.: PC_12/07Schema Nr.: PC_11/07Schema Nr.: PC_10/07 Schema Nr.: PC_13/07Schema Nr.: PC_05/07 Schema Nr.: PC_06/07 Schema Nr.: PC_07/07Schema Nr.: PC_01/07
Kollektorfühler Sonnenkollektor
Solarstation
Spül
vent
ile
EX
T
P
TSKB
[Entlüfter]
Simplex
WW
38°-65°CTh
KW
Solarfühler
EX
13
10
9
8
7
6
4
2
Sphä
rent
ausc
her
FE-Hahn
PRO CLEAN
15
5
16
17
18
11
19
3
Boilerfühler
12
Rückschlagklappe
Umwälzpumpe Absperrventil
Dreiwegventil
Fühler
Thermo-, Manometer
Sicherheitsventil M
ZirkulationKaltwasserWarmwasser
Heizungsrücklauf
Heizungsvorlauf
Solar-RL
Solar-VL
Steuerung
Verbindungswellrohr Vorrangklappe
Th
38°-65°C
Brauchwasser-Mischventil
KW
Schema Nr.: PC 08/07
Heizgruppenversch.
MM
FBH Radiatoren
ÖlPellets
Gas
WW
38°-65°CTh
KW
EX
13
10
9
8
7
6
4
2FE-Hahn
PRO CLEAN
15
5
16
17
18
19
3
Boilerfühler
12
Rückschlagklappe
Umwälzpumpe Absperrventil
Dreiwegventil
Fühler
Thermo-, Manometer
Sicherheitsventil M
ZirkulationKaltwasserWarmwasser
Heizungsrücklauf
Heizungsvorlauf
Solar-RL
Solar-VL
Steuerung
Verbindungswellrohr Vorrangklappe
Th
38°-65°C
Brauchwasser-Mischventil
KW
Schema Nr.: PC_14/07
60°CTh
Fühler Festbrennstoffkessel
M M
FBHRadiatoren
Fühler MinimalbegrenzungHeizungsregler
Fühler Festbrennstoffk.
Festbrenn-11
Kollektorfühler Sonnenkollektor
Solarstation
Spül
vent
ile
EX
T
P
TSKB
[Entlüfter]
M
Radiatoren FBH
M
Kessel min. 48°CKesselfühler im Speicher
alle Anfahrentlastungen "Ein"
gesteuert über Brennerausgang Speicherladepumpe
mit Pumpennachlauf
38°-65°CTh
ÖlPellets
Gas
KW
Solarfühler
EX
13
10
9
8
76
4
2
Sphä
rent
ausc
her
FE-Hahn
PRO CLEAN
15
5
16
17
18
11
19
3
Boilerfühler
KW
12
Kesselfühler
Schema Nr.: PC_02/07
60°CTh
Fühler Festbrennstoffkessel
31
30
Fühler Festbrennstoffk.
Kollektorfühler Sonnenkollektor
Solarstation
Spül
vent
ile
EX
T
P
TSKB
[Entlüfter]
M
FBH
M
38°-65°CTh
KW
Solarfühler
EX
13
10
9
8
76
4
2
Sphä
rent
ausc
her
FE-Hahn
PRO CLEAN
15
5
16
17
18
11
19
3
Boilerfühler
KW
12
Schema Nr.: PC_04/07 WW
38°-65°CTh
KW
EX
13
10
9
8
7
6
4
2FE-Hahn
PRO CLEAN
15
5
16
17
18
19
3
Boilerfühler
12
Rückschlagklappe
Umwälzpumpe Absperrventil
Dreiwegventil
Fühler
Thermo-, Manometer
Sicherheitsventil M
ZirkulationKaltwasserWarmwasser
Heizungsrücklauf
Heizungsvorlauf
Solar-RL
Solar-VL
Steuerung
Verbindungswellrohr Vorrangklappe
Th
38°-65°C
Brauchwasser-Mischventil
KW
Schema Nr.: PC_15/07
11
FBH
M
Ladepumpe Warmwasser
Wärme-
Anlaufverzögerung max. 5 Min.
Ladepumpe Heizung
pumpe
M
32
31
Fühler Heizung
38°-65°CTh
KW
13
10
9
8
7
6
4
2
PRO CLEAN
15
5
16
17
18
19
3
12
Rückschlagklappe
Umwälzpumpe Absperrventil
Dreiwegventil
Fühler
Thermo-, Manometer
Sicherheitsventil M
ZirkulationKaltwasserWarmwasser
Heizungsrücklauf
Heizungsvorlauf
Solar-RL
Solar-VL
Steuerung
Verbindungswellrohr Vorrangklappe
Th
38°-65°C
Brauchwasser-Mischventil
Schema Nr.: PC_16/07
11
WW
Sphä
rent
ausc
her
ÖlPellets
Gas
stoffkessel
Festbrenn-stoffkessel
M
M
Brennwertgerät
oder
Radiatoren
Kollektorfühler Sonnenkollektor
Solarstation
Spül
vent
ile
EX
T
P
TSKB
[Entlüfter]
FBH
M
38°-65°CTh
KW
Solarfühler
EX
13
10
9
8
76
4
2
Sphä
rent
ausc
her
FE-Hahn
PRO CLEAN
15
5
16
17
18
11
19
3
Boilerfühler
KW12
Schema Nr.: PC_03/07
Ladepumpe Warmwasser
Wärme-
Anlaufverzögerung max. 5 Min.
Ladepumpe Heizung pumpe
32
31
M
Fühler Heizung
WW
Rückschlagklappe
Umwälzpumpe Absperrventil
Dreiwegventil
Fühler
Thermo-, Manometer
Sicherheitsventil M
ZirkulationKaltwasserWarmwasser
Heizungsrücklauf
Heizungsvorlauf
Solar-RL
Solar-VL
Steuerung
Verbindungswellrohr Vorrangklappe
13
10
9
8
7
6
4
2FE-Hahn
PRO CLEAN
15
5
16
17
18
19
3
12
Th
38°-65°C
Brauchwasser-Mischventil
KW
Schema Nr.: PC_17/07
11
Zirk. Pumpe
PWT
30
38°-65°CTh
KW
M
55°C
WW
Rückschlagklappe
Umwälzpumpe Absperrventil
Dreiwegventil
Fühler
Thermo-, Manometer
Sicherheitsventil M
ZirkulationKaltwasserWarmwasser
Heizungsrücklauf
Heizungsvorlauf
Solar-RL
Solar-VL
Steuerung
Verbindungswellrohr Vorrangklappe
13
10
9
8
7
6
4
2FE-Hahn
PRO CLEAN
15
5
16
17
18
19
3
12
Th
38°-65°C
Brauchwasser-Mischventil
KW
Schema Nr.: PC_18/07
11
Zirk. Pumpe
PWT
30
M
38°-65°CTh
Simplex Simplex
SimplexSimplex
WW WW
WWWW
Rückschlagklappe
Umwälzpumpe Absperrventil
Dreiwegventil
Fühler
Thermo-, Manometer
Sicherheitsventil M
KaltwasserWarmwasser
Heizungsrücklauf
Heizungsvorlauf
Solar-RL
Solar-VL
Steuerung
Verbindungswellrohr Vorrangklappe
Th
38°-65°C
Brauchwasser-MischventilZirkulation
Rückschlagklappe
Umwälzpumpe Absperrventil
Dreiwegventil
Fühler
Thermo-, Manometer
Sicherheitsventil M
KaltwasserWarmwasser
Heizungsrücklauf
Heizungsvorlauf
Solar-RL
Solar-VL
Steuerung
Verbindungswellrohr Vorrangklappe
Th
38°-65°C
Brauchwasser-MischventilZirkulation
Rückschlagklappe
Umwälzpumpe Absperrventil
Dreiwegventil
Fühler
Thermo-, Manometer
Sicherheitsventil M
ZirkulationKaltwasserWarmwasser
Heizungsrücklauf
Heizungsvorlauf
Solar-RL
Solar-VL
Steuerung
Verbindungswellrohr Vorrangklappe
Th
38°-65°C
Brauchwasser-Mischventil
Rückschlagklappe
Umwälzpumpe Absperrventil
Dreiwegventil
Fühler
Thermo-, Manometer
Sicherheitsventil M
ZirkulationKaltwasserWarmwasser
Heizungsrücklauf
Heizungsvorlauf
Solar-RL
Solar-VL
Steuerung
Verbindungswellrohr Vorrangklappe
Th
38°-65°C
Brauchwasser-Mischventil
Circ. pump
Circ. lance (up to 5 kW circulation losses)
Circulation using plate exchanger for circulation losses over 5 kW.
Volumetric flow and flow velocity
Pressure drop for circulation lancePr
essu
re d
rop
in m
bar
WT 5 CIRCULATION LANCE – CONTD.
Flow velocity < 0.7 m/s
Flow velocity [m/s]
Tap quantity[m3/h]
Tap quantity[l/min]
Circ. pump
203
Flow velocity [m/s]
Tap quantity[m3/h]
Tap quantity[l/min]
Corrugated connection pipeThe corrugated pipe is used to connect 2 tanks and may only be in-stalled in a horizontal position with no sagging (avoid thermosiphon action)! Guide plates are included in the scope of delivery. The pipe nipples should be sealed properly with hemp and sealing compound! Including 19 mm rubber insulation. Transmission capacity up to 50 kW.
Specifications
Corrugated pipe Stainless-steel 1.4404, DN 40, wall thickness 0.5 mm
Union nut Nickel-plated brass, stainless-steel neck, spanner size 56
Flat seal Klingerit
Pipe nipple Brass, spanner size 50, G 1½" with R 1½"
STRATIFIED TANK/FS ACCESSORIESPVS CORRUGATED CONNECTION PIPE
Insulation
Union nut
Flat seal
Pipe nipple 6/4"
Corrugated stainless-steel pipe
when screwed together when screwed together
Use up to 1000 S up to 1500
Item no. 1620025 1620027
Dimension a ca. 846 mm ca. 1196 mm
Type PVS-K PVS-L
Dimension b ca. 1000 mm ca. 1350 mm
204
STRATIFIED TANK/FS ACCESSORIES
Use up to FS 1000 S
Item no. 1620026
Type PVS-K-VK
Dimension a approx. 773 mm
Dimension b 1000 mm
Priority flapA special priority flap allows the upper section of the main tank to be priority-charged when connected to an expansion tank. Can be used with a maximum boiler output of 70 kW. When using a priority flap without a PVS corrugated connection pipe, the uppermost connection line between the main tank and the backup tank has to be fitted on site. Attention should be paid to the flow direction and horizontal installation.
Specifications
Type VK 1
Item no. 1630004
Length 80 mm
Connection 1¼"
Material Red brass with integrated plastic flap
PVS CORRUGATED CONNECTION PIPE
PRIORITY FLAP
Pipe nipple R 6/4 ” Pipe nipple R 6/4 ” Insulation
Corrugated stainless-steel pipe
Pipe nipple R 5/4 ” Pipe nipple R 5/4 ”
Priority flap
Union nut Union nut
Flat seal Flat seal
Pipe nipple G 6/4" Pipe nipple R 6/4"
when screwed together when screwed together
Dummy flange plateCloses the spherical exchanger flange on the Pro-Clean®and Pro-Heat tanks if spherical exchanger is not used. Seal included.
SpecificationsType FLP-ST
Item no. 1620000
DUMMY FLANGE PLATE
205
PS/1R SOLAR STRATIFIED TANK
PS/1R solar stratified tank (prepared for FWM)Tank manufactured according to DIN 4753 Part 1, with a smooth pipe coil made of S 235 JR steel, rough on the inside with rust-protection priming on the outside. Welded joints compliant to DIN 4753 Part 3. All required connections provided. Inflow absorbers for optimum retention of stratification. Includes a mounting facility for solar station and solar expansion tank, as well as for fresh water module
Technical DescriptionMax. operating pressure 3 bar
Max. operating pressure, solar 10 bar
Max. temperature 110 °C
Material S 235 JR; black
Installation Stand ring
Welded joint design DIN 4753 Part 3
Manufacture DIN 4753 Part 1
Specifications
Type PS 500/1R PS 800/1R PS 1000/1R
Item no. 1610790 1610791 1610792
Height without insulation 1.760 mm 1.910 mm 2.120 mm
Height with insulation 1.860 mm 2.010 mm 2.220 mm
Diameter without insulation 650 mm 750 mm 790 mm
Diameter with insulation 850 mm 950 mm 990 mm
Tilt height 1.820 mm 1.975 mm 2.185 mm
Weight 190 kg 225 kg 270 kg
Total volume with register 520 lt 760 lt 980 lt
Solar register
Material S 235 JR steel
Outer diameter 33,7 mm
Inner diameter 29,1 mm
Wall thickness 2,3 mm
Smooth pipe surface area 1,9 m² 2,5 m² 3,1 m²
Length 18 m 24 m 29 m
Windings (number of) 14 17 18
Overall height 800 mm 1000 mm 1100 mm
Average diameter of windings 400 mm 450 mm 500 mm
Contents 16,44 lt 22 lt. 26,5 lt
Max. recommended collector surface 10,5 m² 13 m² 15,5 m²
1) All size specifications are in a tolerance range of +/- 3%
PS/1R PRODUCT DESCRIPTION
206
PS/1R SOLAR STRATIFIED TANKPS/1R PRODUCT DESCRIPTION
PS-1R pressure losses
Flow, m3/hSolar register, mbar
PS/1R 500 (18 m) PS/1R 800 (24 m) PS/1R 1000S (28,3 m)
0,25 3,317 4,423 5,216
0,5 6,635 8,847 10,432
0,75 9,952 13,270 15,647
1 25,829 34,438 40,608
1,25 37,851 50,468 59,510
1,5 51,826 69,101 81,481
1,75 67,691 90,255 106,426
2 85,4 113,867 134,268
0
20
40
60
80
100
120
0,25 0,5 0,75 1 1,25 1,5 1,75 2
PS-1R pressure losses
Volumetric flow, m3/h
Pres
sure
loss
, mba
r
PS/1R 500 Solar register PS/1R 800 Solar register PS/1R 1000S Solar register
Discharge capacity and hot water tap output (+/- 5% deviation)
Fully loaded
Solar register
PS/1R 500 PS/1R 800 PS/1R 1000S
Single discharge capacity (hot water 40 °C) when the backup tank is loaded at 60 °C 385 lt 555 lt 720 lt
Single discharge capacity (hot water 40 °C) when the backup tank is loaded at 55 °C 310 lt 460 lt 590 lt
Single discharge capacity (hot water 40 °C) when the backup tank is loaded at 50 °C 250 lt 360 lt 470 lt
Half loadedSingle discharge capacity (hot water 40 °C) when the backup tank is loaded at 60 °C 243 lt 353 lt 459 lt
Single discharge capacity (hot water 40 °C) when the backup tank is loaded at 55 °C 191 lt 278 lt 360 lt
Single discharge capacity (hot water 40 °C) when the backup tank is loaded at 50 °C 138 lt 202 lt 262 lt
Pipe roughness: 0.04 mm (average seamless steel pipe), Density: 1,038 kg/m³ (40%Tyfocor L/60% water) at 20 °C, Kin. viscosity: 4.5 mm²/s (40%Tyfocor L/60% water) at 20 °C
207
PS/1R SOLAR STRATIFIED TANKPS/1R PRODUCT DESCRIPTION
Kipp
maß
Table of dimensions as per drawingmm PS/1R 500 PS/1R 800 PS/1R 1000S
a 1760 1910 2120
b 1650 1780 1990
c 1270 1450 1530
d 1160 1340 1420
e 1050 1200 1300
f 940 1060 1160
g 830 920 1000
h 640 660 710
i 500 520 520
j 70 70 70
k 1570 1690 1900
l 1517,5 1667,5 1767,5
m 1430 1580 1680
n 1367,5 1517,5 1617,5
o 1350 1500 1610
p 1160 1340 1420
q 1070 1220 1320
r 1008 1158 1258
s 970 1120 1220
t 910 1040 1140
u 710 730 780
v 480 500 500
w 280 300 300
x1 270 350 350
x2 720 725 725
x3 1150 1170 1170
x4 - - 1680
x5 1540 1680 1900
Tilt height 1820 1975 2185
d1 600 750 790
d2 650 830 880
Note: Inflow absorber provided at sleeve 4/6/8/9/10/12/30a/30b.
208
PS/1R sleeve assignment
No. Dimension Use Comment
1 G 1" Connection of heating forward flow for fresh water module Mandatory
2 G 1" Connection of heating return flow for fresh water module Mandatory
3 Rp ½" Venting Mandatory
4 Rp 1 ½" Secondary heat source forward flow (e.g. oil, gas, heat pump HT circuit) Mandatory for secondary heat source
5 ø 6 mm Sensor sleeve for boiler sensor Mandatory
6 Rp 1 ½" Forward flow of heating circuits (radiators or underfloor heating) Depending on hydraulics configuration
7 Rp 2" Electric immersion heater (reduced to 1½") with extension Optional
8 Rp 1 ½" Secondary heat source return flow (e.g. heat pump HT circuit) Mandatory for secondary heat source
9 Rp 1 ½" Heat pump forward flow, LT circuit Depending on hydraulics configuration
10 Rp 1 ½" Underfloor heating return flow Depending on hydraulics configuration
11 ø 6 mm Sensor sleeve for solar sensor Mandatory for solar
12 Rp 1 ½" Heat pump return flow, LT circuit Optional
15 ø 6 mm Sensor sleeve (upper tank temperature) Optional
16 ø 6 mm Sensor sleeve (boiler sensor) Depending on hydraulics configuration
17 ø 6 mm Sensor sleeve (heat pump switch-on sensor, sensor of diªerence control of return flow boost) Depending on hydraulics configuration
18 ø 6 mm Sensor sleeve (heat pump switch-oª sensor, solid fuel boiler sensor) Depending on hydraulics configuration
19 ø 6 mm Sensor sleeve (complete loading e.g. solid fuel boiler) Depending on hydraulics configuration
20 Rp ½" Drainage Mandatory
21 M6 Mounting bolt for solar expansion tank
22 M6 Mounting bolt for solar station
23 M6 Mounting bolt for solar station
24 G 1" Solar station connection, solar forward flow (hot) Mandatory for solar
25 G 1" Solar station connection, solar return flow (cold) Mandatory for solar
26 M10 Mounting bolt for fresh water module
27 M10 Mounting bolt for fresh water module
30a Rp 1 ½" Corrugated connection pipe (possibly with priority flap) Optional forward flow, solid fuel boiler
30b Rp 1 ½" Corrugated connection pipe (possibly with priority flap)
31 Rp 1 ½" Corrugated connection pipe
32 Rp 1 ½" Corrugated connection pipe Optional return flow, solid fuel boiler
33 Rp 1 ½" Corrugated connection pipe Optional return flow, solid fuel boiler
PS/1R SOLAR STRATIFIED TANKPS/1R PRODUCT DESCRIPTION
209
FWM FRESH WATER MODULE PRODUCT DESCRIPTION
Fresh water moduleThe fresh water module guarantees permanently fresh and vital hot water. Required quantities can be supplied without any waiting time or temperature fluctuations. A long service life is ensured by high-quality components and protection against limes-cale deposition due to thermal conditions.
Product advantages: Prevents the development of Legionella bacteria, very fast response times, tank or wall installation, for 1 to 3 family households, separable flat sealing system connection, high tap quantities through utilisation of a large heat exchanger.
Note: For cascading (max. 3 FWM), one overflow valve per expansion is required (not included in the delivery scope - can be ordered separately).
Technical DescriptionItem no. 1610802
Max. tap output 30 l/min
Charger pump 230 V (50 Hz)
Speed 2,200 rpm
Power consumption 95 W
Nominal current 0.4 A
Max. operating pressure, fresh water circuit 10 bar
Max. operating pressure, backup water circuit 3 bar
Cover EPP
Weight 20 kg
Temperatures min.–max.
Ambient 2 °C–40 °C
Backup water 2 °C–95 °C
Connections
Cold water G1" female thread
Hot water G1" female thread
Tank forward flow G1" male thread
Tank return flow G1" male thread
Circulation G½" female thread
Permitted water ingredients and limit values
Water ingredients Unit Limit values (copper-soldered)
pH 7–9 (taking into account the SI index)
Saturation Index SI (delta pH value) -0.2 < 0 < +0.2
Total hardness °dH 6–15
Conductivity μS/cm 10...500
Substances removable by filtration mg/l <30
Free chlorine mg/l <0.5
Hydrogen sulfide (H2S) mg/l <0.05
Ammonia (NH3/NH4+) mg/l <2
Sulfate mg/l <100
Hydrogencarbonate mg/l <300
Hydrogencarbonate/sulfate mg/l >1.0
Sulfide mg/l <1
Nitrate mg/l <100
Nitrite mg/l <0.1
Iron, dissolved mg/l <0.2
Manganese mg/l <0.1
Free aggressive carbonic acid mg/l <20
PS/1R SOLAR STRATIFIED TANK
210
1 Thermostat head2 Connection box3 Plate heat exchanger4 Water switch5 Charger pump6 Coiled sensor7 Push-in connection for circulation unit (incl. blind cap closure)8 Circulation unit (optional)9 Charger pump venting screwA Cold waterB Hot waterC Tank forward flowD Tank return flowE Circulation line (not included in delivery scope)
8
7
5
4
3
2
1
6
B
C
AD
E
9
Tap quantity l/min – Hot water temperature/Return flow temperature °C
Head setting Forward flow temperature °C
35 WW/RL
30 WW/RL
25 WW/RL
20 WW/RL
15 WW/RL
10 WW/RL
5 WW/RL
45
50 °C 30,05/15,33 31,41/16,01 32,64/16,35 33,86/17,07 35,72/17,77 38,32/19,38 41,94/23,2555 °C 31,89/15,68 33,04/16,18 34,19/16,41 35,66/16,92 37,21/17,53 40,38/19,16 42,93/21,2360 °C 33,76/15,89 34,81/16,33 35,78/16,61 37,30/17,02 39,43/17,93 42,41/19,18 44,66/20,4270 °C 34,15/15,06 35,05/15,18 36,22/15,31 37,96/15,67 40,24/16,39 42,55/16,99 44,31/17,7190 °C 36,81/13,54 37,77/13,73 39,27/13,95 41,18/14,22 43,17/14,59 44,39/14,64 45,15/14,80
50
50 °C 30,39/15,42 32,64/16,53 35,66/18,26 37,60/19,46 39,36/20,61 41,71/22,40 44,95/27,9255°C 33,10/16,21 36,33/17,71 37,62/18,34 39,14/19,00 40,95/19,75 43,65/21,46 47,38/25,3160°C 35,84/16,60 38,05/17,64 39,64/18,40 41,09/18,92 42,91/19,64 46,12/21,40 49,19/24,3670°C 37,95/16,49 38,75/16,72 39,96/16,91 41,48/17,21 43,56/17,80 46,76/19,15 48,85/19,8390°C 40,46/14,47 41,73/14,50 42,99/14,57 45,00/14,95 47,27/15,32 49,30/15,60 50,61/15,93
55
50 °C 30,26/15,25 32,50/16,37 35,88/18,22 39,83/21,13 42,70/23,88 44,65/26,52 47,05/32,7455 °C 33,15/16,22 35,92/17,44 39,82/19,55 42,30/21,30 44,35/22,63 46,78/24,72 50,26/30,8260 °C 35,79/16,55 38,87/17,99 42,81/20,08 44,97/21,33 46,76/22,39 49,19/24,22 53,09/29,9370 °C 40,15/17,35 42,12/18,20 43,71/18,85 45,28/19,10 47,15/19,75 50,52/21,43 53,30/23,1690 °C 44,96/17,28 45,87/17,40 47,23/17,59 48,96/17,96 51,40/18,49 53,87/19,24 55,27/19,40
60
50 °C 30,27/15,60 32,92/16,91 35,70/18,41 39,61/21,31 43,73/25,58 46,82/31,68 47,94/39,2455°C 33,08/15,95 35,57/17,25 39,34/19,34 43,84/22,50 47,40/26,00 49,81/29,28 51,97/35,9960°C 36,26/17,51 38,97/18,83 43,16/21,06 47,59/24,12 49,98/26,59 52,15/29,01 55,04/36,1570°C 41,23/18,18 44,32/19,48 47,88/21,36 49,70/22,21 51,58/23,21 54,17/24,59 57,89/28,5290°C 49,32/19,08 50,17/19,24 51,58/19,40 53,06/19,78 55,25/20,20 58,47/21,17 60,29/21,79
65
50 °C 30,71/15,63 32,81/16,58 35,90/18,38 39,88/21,24 44,18/25,96 47,18/31,98 48,30/39,9155 °C 33,10/15,82 35,67/16,96 39,47/19,18 43,94/22,32 48,64/26,94 52,51/34,33 53,73/42,1960 °C 36,57/17,56 39,02/18,72 43,35/20,95 47,67/24,02 53,12/29,49 55,70/34,47 57,46/42,5570 °C 41,34/18,17 44,73/19,68 49,74/22,24 53,69/24,86 55,74/26,20 58,12/27,88 62,12/33,5190 °C 51,20/19,61 54,37/20,84 55,91/21,42 57,53/21,79 59,52/22,03 62,69/23,24 65,09/24,24
70
50 °C 30,15/15,42 32,42/16,46 35,58/18,20 39,37/20,80 43,71/25,24 47,10/31,83 48,31/40,0455°C 32,67/15,67 35,63/16,99 39,33/19,04 43,65/22,02 48,69/27,20 52,48/34,42 54,01/44,0860°C 36,30/17,53 39,32/19,04 43,36/21,38 47,87/24,22 53,13/29,65 57,38/38,65 58,56/47,3770°C 41,08/18,33 44,92/19,88 49,72/22,25 55,72/26,32 59,59/30,14 62,04/32,87 65,30/40,2090°C 51,92/20,35 57,16/22,47 59,85/23,55 61,66/24,05 63,68/24,61 66,84/25,96 69,80/27,52
Fresh water module structure
FWM FRESH WATER MODULE PRODUCT DESCRIPTION
PS/1R SOLAR STRATIFIED TANK
211
4
1
2
3
5
5
A
B
C
E
D
25 kPa
35 kPa
1 Fresh water station – module 12 Fresh water station – module 23 Fresh water station – module 3 (max. 3 modules)4 Circulation unit (optional)5 Overflow valve
A Backup water return flowB Backup water forward flowC Fresh water station – module 3 (max. 3 modules)D Circulation unit (optional)E Overflow valve
Circulation pumpAttachable to the fresh water module using a simple plug-in system. Temperature selection switch and time switch are integrated.
Cascade connection
Technical DescriptionItem no. 1610803
Circulation unit 230 V (50 Hz)
Power consumption 8 W
Nominal current < 0,1 A
1
3
8
9
7
6
2
5
5
41 Circulation pump2 Sealing ring3 Plug-in adapter4 Check valve5 Flat seal6 Shut-oª valve7 Union nut8 Eccentric9 Circulation line (not included in the delivery scope)
FWM FRESH WATER MODULE PRODUCT DESCRIPTION
PS/1R SOLAR STRATIFIED TANK
212
DIAGRAM 1
PS/1R SOLAR STRATIFIED TANK
FWM
T
P
T
ÖlPe
llets
Gas
MM
EX
60°C Th
EX
3 9 106 874 201211 1918175 16
R
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
213
DIAGRAM 2
PS/1R SOLAR STRATIFIED TANK
Wär
me-
pump
e
FWM
T
P
T
M
EX
EX
3 9 106 874 2012
11 191817
5
16
M
M
R
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
214
DIAGRAM 3
PS/1R SOLAR STRATIFIED TANK
FWM
T
P
T
ÖlPe
llets
Gas
Festb
renn
-sto
ffkes
sel
MM
EX
EX
60°CTh
3 9 106 874 2012
11 1918175 16
31 32 33
R
30
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
215
DIAGRAM 4
PS/1R SOLAR STRATIFIED TANK
FWM
T
P
T
Festb
renn
-sto
ffkes
sel
MM
EX
EX
60°CTh
3 9 106 874 2012
11 1918175 16
R
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
216
DIAGRAM 5
PS/1R SOLAR STRATIFIED TANK
T
P
T
ÖlPe
llets
Gas
MM
38°-
65°CTh
EX
EX
3 9 106 874 2012
11 191817
5
16
R
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
217
PS/1R ACCESSORIES
Polyester fibre fleece insulation for PS/1RThree-part polyester fibre fleece insulation1, 100 mm, with textured grey polystyrene outer shell (RAL 9022), which is 1 mm thick. Adjustable clip locking rails, including lid and base insu-lation. Best heat insulation properties guaranteed, insulation fire resistance class B2, CFC-free and 100 % recyclable.
POLYESTER FIBRE FLEECE INSULATION
Specifications
Property Test method Value Units
Density - 12 kg/m3
Fogging behaviour DIN 75201 B < 0,2 mg
Formaldehyde Emission VDA 275 < 2 mg/kg
Fire test DIN 75200 < 100 mm/min
Fire resistance class DIN 4102 B2 -Fire resistance class in a compound DIN 4102 B2 -
Continuous connection temperature - max. 130 °C
Colour - white -Thermal conductivity of the insulation - 0,041 W/mK
Dimensions
Type ISOVL PS/1R 500
ISOVL PS/1R 800
ISOVL PS/1R 1000S
Item no. 1610797 1610798 1610799Diameter 850 mm 950 mm 1050 mmThickness 100 mm
218
In compliance with DIN 4753 part 1 manufactured tank made of S 234 JR steel, rough on the inside with rust-protection primer on the outside. All required connections provided. Without insulation, max. operating pressure 3 bar, max. temperature +110 °C.
PS BACKUP TANK
Technical description
Max. operating pressure 3 bar
Max. temperature 110°C
Material S 235 JR; Metal plate wall thickness 3 mm, black
Installation Stand ring
Welded joint design DIN 4753 Part 3
Production DIN 4753 Part 1
Type PS 2000 PS 2500 PS 3000 PS 4000 PS 5000
Item no. 1610661 1610662 1610663 1610664 1610665
Height without insulation 2280 mm 2170 mm 2645 mm 2290 mm 2850 mm
Height with insulation 2380 mm 2270 mm 2770 mm 2400 mm 2910 mm
Cylinder height 1710 mm 1500 mm 2005 mm 1500 mm 2060 mm
Base and lid height 260 mm 310 mm 295 mm 370 mm 370 mm
Diameter without insulation 1100 mm 1300 mm 1250 mm 1600 mm 1600 mm
Diameter with insulation 1300 mm 1500 mm 1470 mm 1820 mm 1820 mm
Tilt height 2380 mm 2350 mm 2780 mm 2520 mm 2945 mm
Weight 305 kg 380 kg 415 kg 510 kg 520 kg
Metal plate wall thickness 3 mm 3 mm 3 mm 4 mm 4 mm
Cover and floor plate thickness 4 mm 5 mm 4 mm 5 mm 5 mm
Cylinder volume 1625 lt 1991 lt 2461 lt 3016 lt 4022 lt
Base and lid volume 140 + 140 lt 214 + 214 lt 190 + 190 lt 400 + 400 lt 400 + 400 lt
Total volume 1905 lt 2419 lt 3221 lt 3816 lt 4822 lt
Specifications
Type PS 500 PS 800 PS 1000B PS 1000S PS 1250 PS 1500
Item no. 1610655 1610656 1610657 1610658 1610659 1610660
Height without insulation 1760 mm 1910 mm 1950 mm 2120 mm 2200 mm 2190 mm
Height with insulation 1860 mm 2010 mm 2050 mm 2220 mm 2300 mm 2290 mm
Cylinder height 1390 mm 1500 mm 1500 mm 1710 mm 1740 mm 1650 mm
Base and lid height 160 mm 180 mm 200 mm 180 mm 205 mm 245 mm
Diameter without insulation 650 mm 750 mm 850 mm 790 mm 900 mm 1000 mm
Diameter with insulation 850 mm 950 mm 1050 mm 990 mm 1100 mm 1200 mm
Tilt height 1800 mm 1965 mm 2020 mm 2180 mm 2270 mm 2280 mm
Weight 130 kg 155 kg 185 kg 185 kg 215 kg 247 kg
Metal plate wall thickness 3 mm 3 mm 3 mm 3 mm 3 mm 3 mm
Cover and floor plate thickness 3 mm 3 mm 3 mm 3 mm 4 mm 4 mm
Cylinder volume 461 lt 663 lt 851 lt 838 lt 1107 lt 1295 lt
Base and lid volume 30 + 30 lt 47 + 47 lt 66 + 66 lt 50 + 50 lt 77 + 77 lt 90 + 90 lt
Total volume 521 lt 757 lt 983 lt 983 lt 1261 lt 1475 lt
PRODUCT DESCRIPTION PS
1) All size specifications are in a tolerance range of +/- 3%
SpecificationsSpecifications
219
45°
D1
50
n o pg1
f
ai
h
de
b c
j
lm
k
D2
100
g2
100
1/2"
6/4"
6/4"
6/4"
6/4"
6/4"
6/4"
6/4"
6/4"
1/2"
1/2"
6/4"
2
1
3
4
6
5a
7
8
91011
12
13
15
14
5b
PS BACKUP TANKPS SPECIFICATIONS
Table of dimensions as per illustrations
Type PS500
PS800
PS 1000B
PS 1000S
PS 1250
PS 1500
PS 2000
PS 2500
PS 3000
PS 4000
PS 5000
a 1760 mm 1910 mm 1950 mm 2120 mm 2200 mm 2190 mm 2280 mm 2170 mm 2645 mm 2290 mm 2790 mmb 240 mm 265 mm 290 mm 270 mm 295 mm 340 mm 350 mm 400 mm 390 mm 450 mm 455 mmc 320 mm 345 mm 370 mm 350 mm 375 mm 420 mm 430 mm 480 mm 470 mm 480 mm 500 mmd 730 mm 790 mm 810 mm 850 mm 900 mm 910 mm 940 mm 920 mm 1080 mm 945 mm 1145 mme 1140 mm 1235 mm 1250 mm 1350 mm 1420 mm 1400 mm 1450 mm 1370 mm 1690 mm 1045 mm 1790 mmf 1550 mm 1680 mm 1700 mm 1850 mm 1940 mm 1890 mm 1960 mm 1810 mm 2295 mm 1870 mm 2370 mm
g1 1540 mm 1680 mm 1680 mm 1900 mm 1700 mm 1890 mm 1950 mm 1810 mm 2200 mm 1700 mm 2300 mmg2 – – – 1680 mm – – – – – – –h 1150 mm 1170 mm 1170 mm 1170 mm 1170 mm 1280 mm 1370 mm 1360 mm 1460 mm 1170 mm 1600 mmi 720 mm 725 mm 725 mm 725 mm 725 mm 775 mm 860 mm 880 mm 880 mm 725 mm 950 mmj 270 mm 350 mm 350 mm 350 mm 350 mm 350 mm 350 mm 400 mm 415 mm 350 mm 350 mmk 260 mm 325 mm 350 mm 330 mm 335 mm 400 mm 410 mm 450 mm 440 mm 495 mm 505 mml 710 mm 770 mm 790 mm 830 mm 880 mm 890 mm 920 mm 890 mm 1050 mm 915 mm 1115 mmm 1120 mm 1215 mm 1230 mm 1330 mm 1400 mm 1380 mm 1430 mm 1340 mm 1660 mm 1375 mm 1760 mmn 1430 mm 1535 mm 1550 mm 1740 mm 1800 mm 1760 mm 1830 mm 1670 mm 2155 mm 1725 mm 2225 mmo 1510 mm 1615 mm 1630 mm 1820 mm 1880 mm 1840 mm 1910 mm 1750 mm 2235 mm 1805 mm 2305 mmp 1565 mm 1695 mm 1710 mm 1900 mm 1960 mm 1920 mm 1990 mm 1830 mm 2315 mm 1885 mm 2385 mm
D1 650 mm 750 mm 850 mm 790 mm 900 mm 1000 mm 1100 mm 1300 mm 1250 mm 1600 mm 1600 mmD2 850 mm 950 mm 1050 mm 990 mm 1100 mm 1200 mm 1300 mm 1500 mm 1470 mm 1820 mm 1820 mmTilt
height 1800 mm 1965 mm 2020 mm 2180 mm 2270 mm 2280 mm 2380 mm 2350 mm 2780 mm 2520 mm 2945 mm
1) Insulation thickness of PS 3000, PS 4000 und PS 5000 is 110 mm
PS backup tank sleeve assignment
No. Dimensions Use
1 Rp 1½" Functional sleeve (plate heat exchanger connection etc.)
2 Rp 1½" Functional sleeve (plate heat exchanger connection etc.)
3 Rp 1½" Functional sleeve (plate heat exchanger connection etc.)
4 Rp 1½" Functional sleeve (plate heat exchanger connection etc.)
5a5b Rp 1½" Connection sleeve toPro-Clean® / FS tank
6 Rp 1½" Connection sleeve toPro-Clean® / FS tank
7 Rp 1½" Connection sleeve toPro-Clean® / FS tank
8 Rp 1½" Connection sleeve toPro-Clean® / FS tank
9 Rp ½" De-aeration
10 Rp ½" Temperature sensor
11 di=6mm Temperature sensor
12 di=6mm Temperature sensor
13 di=6mm Temperature sensor
14 Rp ½" Drain
15 di=6mm Access flange
* Only for PS1000S
*
1)
insulation
insulation
3/4" closed
tilt h
eigh
t
220
PS BACKUP TANK
Polyester fibre fleece insulation for backup tanks PSThree-part polyester fibre fleece insulation1), 100 mm with textured grey polystyrene outer shell (RAL 9022), which is 1 mm thick. Adjustable clip locking rails, including lid and base insu-lation. Best heat insulation properties guaranteed, insulation fire resistance class B2, CFC-free and 100 % recyclable.
PS ACCESSORIES
Specifications
Property Test method Value Units
Density - 12 kg/m3
Fogging behaviour DIN 75201 B < 0,2 mg
Formaldehyde Emission VDA 275 < 2 mg/kg
Fire test DIN 75200 < 100 mm/min
Fire resistance class DIN 4102 B2 -Fire resistance class in a compound DIN 4102 B2 -
Continuous connection temperature - max. 130 °C
Colour - white -Thermal conductivity of the insulation - 0,041 W/mK
Dimensions
Type ISOVL PS 500
ISOVL PS 800
ISOVL PS 1000 B
ISOVL PS 1000 S
ISOVL PS 1250
ISOVL PS 1500
Item no. 1610873 1610874 1610875 1610876 1610877 1610878Diameter 850 mm 950 mm 1050 mm 990 mm 1100 mm 1200 mmThickness 100 mm
Type ISOVL PS 2000
ISOVL PS 2500
ISOVL PS 3000
ISOVL PS 4000
ISOVL PS 5000
Item no. 1610879 1610880 1610881 1610882 1610883Diameter 1300 mm 1500 mm 1470 mm 1820 mm 1820 mmThickness 100 mm 110 mm
221
Specifications
Item no. 1610608
Thread Rp 1½"-R 1½"Thread length 400 mmDesign EPD-coatedSpanner size 55 mmMax. volume flow 5 m3/h
Inflow pipeThe inflow pipe provides a steady flow into the heating tank The distribution is optimised by the conical shape. Installation is possible on PS backup tanks with Rp 1 sleeves½ ” female thread. Assembly proceeds with the respective sleeves for the heating process.
PS BACKUP TANK ACCESSORIESINFLOW PIPE
222
Solar hot water tank BE-SSP-2RHot water tank made of S 235 JR steel with one pipe heating coil at the top (secondary heat source) and one solar heat exchanger at the bottom (solar), with direct enamelling to DIN 4753, including magnesium anode. All required connections provided. Max. opera-ting pressure 10 bar, max. temperature +95 °C. Up to 500 litres, including insulation (fixed foam), more than 750 litres, without insulation. Option to install solar station and expansion container on tank.
PRODUCT DESCRIPTION BE-SS P-2R
SOLAR HOT WATER TANK BE-SSP-2R
GeneralBE-SSP-
2RBE-SSP-
2RBE-SSP-
2RBE-SSP-
2RBE-SSP-
2RBE-SSP-
2R
Designation Type 200 300 400 500 750 1000
Nominal volume lt 184 283 365 452 728 952Diameter D2 mm 540 600 700 700 950 1050Diameter without insulation d1 mm – – – – 750 850Height G mm 1432 1794 1591 1921 2043 2070Height without insulation mm – – – – 1931 1959Tilt height OK mm 1.514 1.876 1.712 2.023 2.098 2.150Insulation thickness mm 45 50 50 50 100 100Standing losses over 24 hours kWh 2,3 2,6 2,9 3,2 2,2 2,4
Max. operating pressureHot water
Solar Domestic water
barbarbar
31010
31010
31010
31010
31010
31010
Max. operating temperatureHot water
Domestic water°C°C
11095
11095
11095
11095
11095
11095
Standby volume lt. 88 121 133 202 353 462Weight kg 63 106 122 137 208 259Packaged weight kg 75 116 132 149 221 272
Specifications
Type BE-SSP-2R 200
BE-SSP-2R 300
BE-SSP-2R 400
BE-SSP-2R 500
BE-SSP-2R 750
BE-SSP-2R 1000
Item no. 1610711 1610712 1610713 1610714 1610715 1610716
Material S 235 JR
Surface treatment Outer wall Fixed foam Water enamel, black
Surface treatment Inner wall Direct enamelling in compliance with DIN 4753
Installation 3 adjustable feet
Corrosion protection Magnesium anode, insulated, installed from above (replace with chain anode)
InsulationCFC-free PU-foam, 50 mm, fixed foam,
with silver RAL 9007 covering filmThermal conductivity = 0.034 W/mK
Three part polyester fibre fleece insulation, with a grey outer top-coat of sturdy laminated polysty-rene (RAL 9022). With adjustable clip rails. Fire resistance class B2, including lid insulation, good ther-mal properties. CFC-free and 100% recyclable.
223
(9) (18)
(9) (18)d1D2
0 0 0 0
d1D2
Connection dimensions
Nr. BE-SSP-2R 200 300 400 500 750 1000
Connection sizeCold waterHot water
1513
KWWW
Rmmmm
3/4"55
1369
1"90
1728
1"55
1526
1"55
1856
1 1/4"99
1887
1 1/4"103
1905Connection sizeSolar forward flow / solar return flow
11 / 12 SV / SR Rmm
1"687
1"845
1"909
1"966
1"830
1"839
Connection sizeHeating forward flowHeating return flow
14
HVHR
Rmmmm
1"1147
787
1"14251065
1"13551007
1"16051115
1"14301115
1"14391124
Connection sizeCirculation
3 Z Rmm
3/4"900
3/4"1180
3/4"1112
3/4"1265
3/4"1205
3/4"1214
Sensor tube (dia. 6 mm) 8a8b
HeatingSolar
mmmm
1147 281
1290 405
1217 319
1410 381
1296 402
1314 411
Access flangeDummy flange diameter
17 DNTK
mmmm
247150
310150
276150
276150
378225
386225
Sleeve for electric heating 5 EP (Rp 1½") mm 737 1015 957,5 1040 1015 1024De-aeration 18 RP 1" 1" 1" 1" 1 1/4" 1 1/4"Magnesium anode 9 RP 1" 1" 1" 1" 1 1/4" 1 1/4"
BE-SSP-2R SPECIFICATIONS
SOLAR HOT WATER TANK BE-SSP-2R
Register for secondary heat sourceUpper heating surfaceVolume of the heating heat exchangers
m2
I0,604,20
0,85,50
0,866,00
1,087,57
1,178,15
1,379,60
Rated load
Rated lower power outputRated upper power output
tKW = 10°CtSp = 60°C
tWW = 45°C
4,22,3
8,42,5
15,25,7
19,18,9
21,06,2
26,07,1
Drinking-water side pressure dropFor continuous output
mbar 10 8 11 14 3 5
Solar registerLower heating surfaceVolume of the solar heat exchangersrecommended collector area
m2
Im2
1,007,00
6
1,309,00
8
1,7011,70
10
1,8212,75
12
1,9013,26
14
2,0614,42
16
BE-SSP-2R 200-500 litres BE-SSP-2R 750-1000 litres
WW (13)
WW (13)OK
OK
EP (5) EP (5)
DN (17)DN (17)
G
G
HV (1)HV (1)
HF (8a)HF (8a)
Z (3)Z (3)
HR (4)HR (4)
SV/SR (11/12)
SV/SR (11/12)
SF (8b)SF (8b)
KW (15)KW (15)
224
PRESSURE DROP CURVE FOR REGISTER BE-SSP-2R
SOLAR HOT WATER TANK BE-SSP-2R
0
200
400
600
800
1000
1200
0 1 2 3 4 5 6
0
100
200
300
400
500
600
700
0 1 2 3 4 5 6
0
200
400
600
800
1000
1200
0 1 2 3 4 5 6
0
100
200
300
400
500
600
700
0 1 2 3 4 5 6
BE-SSP-2R 200
BE-SSP-2R 300
BE-SSP-2R 400
BE-SSP-2R 500
BE-SSP-2R 750
BE-SSP-2R 1000
Pressure drop BE-SSP-2R upper secondary heat source register
Pressure drop BE-SSP-2R lower solar register
BE-SSP-2R 200
BE-SSP-2R 300
BE-SSP-2R 400
BE-SSP-2R 500
BE-SSP-2R 750
Q (m³/h)
Q (m³/h)
p (mbar)
p (mbar)
BE-SSP-2R 1000
Pressure drop with water at 80 °C (density 0.973 g/cm³, kinematic viscosity 0.37 mm²/s)
Pressure drop with water-propylene glycol 1.2 (60%/40%) at 60 °C (density 1.013 g/cm³, kinematic viscosity 0.37 mm²/s)
225
PERFORMANCE CURVES OF BE-SS P-2R COILS
SOLAR HOT WATER TANK BE-SSP-2R
0
5
10
15
20
25
30
35
40
45
0 1 2 3 4 5 6 C [m³/h]
P [kW]
0
100
200
300
400
500
600
700
800
900
1000
1100
L [l/h]
ΔT = 30°C
ΔT = 20°CΔT = 10°C
0 1 2 3 4 5 6 C [m³/h]0
10
20
30
40
50
60
70
80
90
100P [kW]
0100200300400500600700800900100011001200130014001500160017001800190020002100220023002400
L [l/h]
ΔT = 30°C
ΔT = 20°C
ΔT = 10°C
0
10
20
30
40
50
60
70
80
90
0 1 2 3 4 5 6 C [m³/h]
P [kW]
01002003004005006007008009001000110012001300140015001600170018001900200021002200
L [l/h]
ΔT = 30°C
ΔT = 20°C
ΔT = 10°C
0
10
20
30
40
50
60
70
80
0 1 2 3 4 5 6 C [m³/h]
P [kW]
0100200300400500600700800900100011001200130014001500160017001800190020002100
L [l/h]
ΔT = 30°C
ΔT = 20°C
ΔT = 10°C
0 1 2 3 4 5 6 C [m³/h]
P [kW]
010020030040050060070080090010001100120013001400150016001700
L [l/h]
ΔT = 30°C
ΔT = 20°C
ΔT = 10°C
20
50
70
0 1 2 3 4 5 6 C [m³/h]0
10
30
40
60
80
90
100
110
P [kW]
02004006008001000120014001600180020002200240026002800
L [l/h]
ΔT = 30°CΔT = 20°C
ΔT = 10°C
50
10152025303540455055606570
BE-SSP-2R 200
Tank - performance chart
Tank - performance chart
Tank - performance chart
Tank - performance chart
Tank - performance chart
Tank - performance chart
BE-SSP-2R 400
BE-SSP-2R 750
BE-SSP-2R 500
BE-SSP-2R 300
BE-SSP-2R 1000
T1 = 90°C
T1 = 90°C
T1 = 90°C
T1 = 90°C
T1 = 90°C
T1 = 90°C
T1 = 90°C
T1 = 90°C
T1 = 90°C
T1 = 90°C
T1 = 90°C
T1 = 90°C
T1 = 70°C
T1 = 70°C
T1 = 70°C
T1 = 70°C
T1 = 70°C
T1 = 70°C
T1 = 70°C
T1 = 70°C
T1 = 70°C
T1 = 70°C
T1 = 70°C
T1 = 70°C
T1 = 55°C
T1 = 55°C
T1 = 55°C
T1 = 55°C
T1 = 55°C
T1 = 55°C
Solar
Solar
Solar
Solar
Solar
Solar
Heating
Heating
Heating
Heating
Heating
Heating
T1 = 55°C
T1 = 55°C
T1 = 55°C
T1 = 55°C
T1 = 55°C
T1 = 55°C
T1 = 80°C
T1 = 80°C
T1 = 80°C
T1 = 80°C
T1 = 80°C
T1 = 80°C
T1 = 80°C
T1 = 80°C
T1 = 80°C
T1 = 80°C
T1 = 80°C
T1 = 80°C
226
DIAGRAM 1
SOLAR HOT WATER TANK BE-SSP-2R
1 3 4 5
11/1
2
1513
9
8a 8b
P
EX
MM
Th
R
Heat
ing
forw
ard
flow
/Sol
ar V
LCh
eck
valv
eSe
nsor
Circ
ulat
ion
pum
pBl
ocki
ng v
alve
Pres
sure
relie
f val
veTh
ree-
way
con
trol v
alve
/Mix
ing
valv
e
Ther
mo-
, man
omet
erDo
mes
tic h
ot w
ater
mix
ing
valv
e
Prio
rity
flap
Cont
rol u
nit
Heat
ing
retu
rn fl
ow/S
olar
RL
Cont
rol
Hot w
ater
Cold
wat
er
Circ
ulat
ion
Corr
ugat
ed c
onne
ctio
n pi
pe
227
Dimensions
Type ISOVL-BE-SSP-2R 750 ISOVL-BE-SSP-2R 1000
Item no. 1610709 1610710
Diameter 950 mm 1000 mm
Thickness 100 mm 100 mm
Polyester fibre fleece insulation for solar tank BE-SSP-2RThe outer shell is made of hard synthetic polystyrene film, which is 1 mm thick with a grey (RAL 9022) textured surface. The inner insulation shell is made of polyester fibre fleece. The three-part shell is assembled using adjustable clip locking rails. Including lid and base insulation as well as EPS sealing plugs. Entire insulation: Fire resistance class B2, contains no CFCs and is 100% recyclable.
SOLAR HOT WATER TANK BE-SSP-2RACCESSORIES BE-SSP-2R
Specifications
Property Testmethode Wert Einheit
Density - 12 kg/m
Fogging behaviour DIN 75201 B < 0,2 mg
Formaldehyde emission VDA 275 < 2 mg/kg
Fire test DIN 75200 < 100 mm/min
Fire resistance class DIN 4102 B2 -
Fire resistance class in com-pound DIN 4102 B2 -
Continuous connection tem-perature - max. 130 °C
Colour - white -
Thermal conductivity of the insulation - 0,041 W/mK
228
Flange platesFlange plates, double enamelled or varnished black as required, including seal and screws.Flange platesFlange plates, double enamelled or varnished black as required, including seal and screws.
Specifications
Type FLPS 34 FLPS 1 FLPE-SSP 64
Item no. 1610041 1610040 1610204
Material S 235 JR S 235 JRColour Black RAL 9017 Enamelled DIN 4753Plate thickness (Maß x)
10 mm 10 mm
Suitable for PSN tank BE-SSP tank up to 500 litres
Sealing side
enamelled
FLPE 64 BE-SSP-E up to 500 l flange plate DN 110
TANK ACCESSORIESFLANGE PLATES
229
Solar/heating plate heat exchangerThe plate heat exchangers are made of thin, corrugated stainless-steel (AISI 316) plates, soldered together under vacuum using copper as solder. Max. design temperature is 160 °C, max. design pressure is 16 bar for types PWT 10N-50N and 32 bar for all the other types.
Solar/swimming pool plate heat exchangerThe plate heat exchangers are made of thin corrugated stainless-steel (AISI 316) plates, joined using stainless-steel diªusion technology. (Corrosion resistant like stainless-steel) A higher pressure, temperature and corrosion resistance compared to copper-soldered plate heat exchangers is achieved in this manner. (See following pages).
Thermal insulationMade of polyurethane with blue ABS coating. Insulation thickness: 30 mm, max. temperature: 140 °C.
Screw connectionsMade of red brass with male thread.
Foot and mounting bracketsMade of galvanised steel. Types PWT 100N-200N may be floor or wall mounted. Types PWT 300N-500N may only be floor mounted.
PLATE HEAT EXCHANGER
TANK ACCESSORIES
Specifications
Type PWT 10N PWT 20N PWT 30N PWT 50N PWT 80N PWT 100N
Item no. 1610364 1610365 1610366 1610367 1610368 1610369Max. collector surface area up to 10 m2 up to 20 m2 up to 30 m2 up to 50 m2 up to 80 m2 up to 100 m2
Power 7 kW 14 kW 21 kW 35 kW 56 kW 70 kWPressure drop, primary 9.19 kPa 10.8 kPa 11.6 kPa 12.7 kPa 9.97 kPa 10.7 kPaPressure drop, secondary 9.04 kPa 12 kPa 13.6 kPa 16 kPa 14.1 kPa 15.1 kPaHeight without insulation 324 mm 324 mm 324 mm 324 mm 526 mm 526 mmHeight with insulation 384 mm 384 mm 384 mm 384 mm 588 mm 588 mmWidth without insulation 94 mm 94 mm 94 mm 94 mm 111 mm 111 mmWidth with insulation 157 mm 157 mm 157 mm 157 mm 182 mm 182 mmDepth without insulation 50 mm 59 mm 68 mm 92 mm 151 mm 175 mmDepth with insulation 113 mm 113 mm 113 mm 158 mm 160 mm 257 mmWeight (net/operation) 1.86/2.17 kg 2.34/2.82 kg 2.82/3.47 kg 4.10/5.19 kg 12.1/15.8 kg 14.3/18.9 kgConnections (solar-secondary) 1" - 1" 1" - 1" 1" - 1" 1" - 1" 1" - 1 ¼" 1" - 1 ¼"
Type PWT 200N PWT 300N PWT 500N PWT-SB 20 PWT-SB 50 PWT-SB 100
Item no. 1610370 1610371 1610372 1610373 1610374 1610375Max. collector surface area up to 200 m2 bis 300 m2 bis 500 m2 up to 20 m2 up to 50 m2 up to 100 m2
Power 140 kW 220 kW 350 kW 12 kW 30 kW 60 kWPressure drop, primary 12.7 kPa 14,1 kPa 13,8 kPa 1.37 kPa 1.64 kPa 2.08 kPaPressure drop, secondary 15.8 kPa 16,1 kPa 16,6 Kpa 5.82 kPa 7.61 kPa 8.95 kPaHeight without insulation 526 mm 616 mm 616 mm 310 mm 310 mm 310 mmHeight with insulation 588 mm 670 mm 670 mm 360 mm 360 mm 360 mmWidth without insulation 111 mm 191 mm 191 mm 111 mm 111 mm 111 mmWidth with insulation 182 mm 240 mm 240 mm 185 mm 185 mm 185 mmDepth without insulation 295 mm 198 mm 283 mm 97 mm 150 mm 246 mmDepth with insulation 304 mm 247 mm 334 mm 112 mm 160 mm 257 mmWeight (net/operation) 25.4/34.8 kg 24 / 33,5 kg 33,7 / 49,5 kg 4.36/5.22 kg 7.11/9.07 kg 12.1/16.1 kgConnections (solar-secondary) 1" - 1 ¼" 2" - 2" 2" - 2" 1" - 1¼" 1" - 1¼" 1" - 1¼"
AccessoriesType Height Width Suitable for
Mounting brackets BB 80-200 155 mm 100 mm PWT 100N-200NFoot bracket FK 200-500 199 mm 260 mm PWT 300N-500N
230
0,00
5,00
10,00
15,00
20,00
25,00
30,00
35,00
40,00
45,00
150450
7501050
15002250
30003700
59508950
12650
PWT 10N PWT 20N PWT 30N PWT 50NPWT 80N PWT 100N PWT 200N PWT 300NPWT 500N PWT -SB 20 PWT -SB 50 PWT -SB 100
0,00
10,00
20,00
30,00
40,00
50,00
60,00
200600
10001400
20003000
40005000
800012000
17000
PWT 10N PWT 20N PWT 30N PWT 50NPWT 80N PWT 100N PWT 200N PWT 300NPWT 500N PWT -SB 20 PWT -SB 50 PWT -SB 100
TANK ACCESSORIES PLATE HEAT EXCHANGER PRESSURE DROP
Flow quantities l/h
Plate heat exchanger primary side pressure drop (prop. glycol 46%)
Pres
sure
dro
p kP
a
Plate heat exchanger secondary side pressure drop (water)
Flow quantities l/h
Pres
sure
dro
p kP
a
231
Effects of water constituents in hot water sys-tems on copper soldered plate heat exchangersThe following water quality values should be observed for hot water systems in order to minimise the corrosion eªects in copper soldered plate heat exchangers:
Further corrosion-relevant factors include:Water contamination, flow rates, impurities/incrustation in heat exchangers and mixing installations. The figures are provided as guidelines and do not represent a basis for warranty.
Effects of chloride ion concentration and temperature on pitting and stress crack corrosion tendency in stainless-steel.
Other factors influencing these types of
corrosion include: • pH value• Surface properties • Water velocity • Impurities (biological and incrustation) • Contaminants such as CO, HS, SO, iron • Redox potential of the solution (depending on oxidizing substances
such as oxygen, hypochlorous acids, Sodium bicarbonate)
pH value 7 to 9 Free chlorine < 0.5 ppmSO4
-- < 100 ppm Fe+++ < 0.5 ppmHCO3
-/SO4-- > 1 Mn++ < 0.05 ppm
Cl- < 50 ppm CO2 < 10 ppmPO4
-- < 2 ppm H2S < 50 ppbNH3 < 0.5 ppm Conductivity > 50 μS/cm
< 600 μS/cm Wall tempera-ture
< 80 °CSolar/heating
PrimarySolar
SecondaryHeating
Solar/swimming pool
PrimarySolar
SecondarySwimming
pool
PLATE HEAT EXCHANGER TEMPERATURE EXAMPLES
TANK ACCESSORIES
No corrosion
Corrosion
Alloy 20/16/6 (Avesta 254 SMO)
This information is given as a guide-line only and is not a warranty
232
EEH electric screw-in heating elementThese electric screw-in heating elements are used for heating water in boilers and backup tanks. They have an external thermostat and an integrated safety temperature limiter. With a 1½" connection and an unheated zone of 150 mm, suitable for use in containers with up to 150 mm insulation. The extension sleeve required for this purpose (= reduction from 2", item no. 1610609) is available as an accessory. Protection class IP 44.
ImportantIn accordance with VDE regulation VDE0700, Part 73 (open containers) and Part 253 (closed containers), a scalding safeguard (= domestic hot water mixing valve) is compulsory for installation of an electrical immersion heater with a control range above 60 °C!
Pipe material stainless-steel (incoloy)
Surface loading up to 12 W/cm2
Thermostat external with safety temperature limiter
Construction soldered Protection class IP 44
Immersion depth to 690 mm
Approved according to VDE regulations
Specifications
Type Power kW Voltage Immersion depth Control range Item no.
EEH 2000 2.00 230 320 mm 5-75 °C 1610468
EEH 2500 2.50 230 390 mm 5-75 °C 1610469
EEH 3000 3.00 230 390 mm 5-75 °C 1610470
EEH 3750 3.75 400 390 mm 5-75 °C 1610471
EEH 4500 4.50 400 470 mm 5-75 °C 1610472
EEH 6000 6.00 400 470 mm 5-75 °C 1610473
EEH 9000 9.00 400 690 mm 5-75 °C 1610474
Product benefits
TANK ACCESSORIES ELECTRIC SCREW-IN HEATING ELEMENT
150 mm unheated zone
6/4" male thread
Housingmax
. 38
mm
233
EFH Electric screw-in heating elementThe electric flange heating provides hot water heating in larger boilers and backup tanks. Installation by flange connections of dimension DN 200. Unheated zone 150 mm long. The flange heating is installed as a dual circuit with, in each case, an external thermostat and a safety temperature limiter. Temperature control in the range 5-75 °C. Safety temperature limiter fixed at 95 °C. Protection class IP 44.
ImportantIn accordance with VDE regulation VDE0700, Part 73 (open containers) and Part 253 (closed containers), a scalding safeguard (= domestic hot water mixing valve) is compulsory for installation of an electrical immersion heater with a control range above 60 °C!
Pipe material stainless-steel (incoloy)
Surface loading up to 12 W/cm2
Thermostat external with safety temperature limiter
Construction soldered Protection class IP 44
Immersion depth to 700 mm
Approved according to VDE regulations
Specifications
Type Power kW Voltage Installation depth Item no.
EFH 12 12 400 550 mm 1610483
EFH 18 18 400 550 mm 1610484
EFH 30 30 400 700 mm 1610485
Product benefits
TANK ACCESSORIES EFH ELECTRIC FLANGE HEATING
Installation depth
Flange DN 200
245 mm diameter bolt circle
234
TANK ACCESSORIESCIRCULATION UNIT
DescriptionThis pump group provides hot water circulation in sanitary systems The advantages are the immediate availability of hot water (lower water consumption) and protection from Legionella. The hot water temperature is always held constant by action of the integrated thermostatic mixing valve. A bypass from the circulation pipe to the mixing valve minimises the energy loss in the hot water circulation. Unfavourable fluid flow is prevented by integrated check valves. The ready-to-install component is completely insulated and assembled. The circulation pump can be adjusted to the desired circulation temperature by means of the in-built thermostat.
SpecificationsType ALS 1500
Item no. 1610610
Connections 1" male threadMax. discharge capacity 1500 l/h with 1bar pressure dropInsulation Material EPP
Thermal conductivity 0.041 W/mKMax. temperature 120 °C
Temperature for short periods up to 180 °CHeight 360 mmWidth 340 mmDepth 180 mm
Individual parts Under shell 360 x 340 x 65Over shell 360 x 340 x 115
Circulation pump Type Laing ECOCIRC-E1 15/700BRInstallation length 65 mm
Max. delivery pressure 15 kPaTemperature range -10 °C/+110 °CHousing material Bronze
Max. power consumption 8 WMax. operating pressure 10 bar
Thermostat adjustment range 20 °C-70 °C
E1-15/700 B power consumption
Pow
er c
onsu
mpt
ion
(W)
E1-15/700 B characteristics curves Pump capacity (l/h)
Pump characteristics curves and power consumption
Pum
p ca
paci
ty (m
)
0 200 400 600 800 1000 12000,0
0,2
0,4
0,6
0,8
1,0
1,2
1,4
1,6
0
8
16
24
32
235
Shut-off valve with temperature measurement Material BrassTemperature range 0 °C-120 °C
Dimensions 1"Installation length 65 mm
Installation location Hot water pipeMixed water pipe
Shut-off valve with sensor thimble Material BrassDimensions 1"
Installation length 65 mmInstallation location Circulation pipe
Shut-off valve Material BrassDimensions 1"
Installation length 65 mmInstallation location Cold water pipe
Circulation pipeCheck valves Material Plastic
Installation location Mixing valve on hot water sideMixing valve on cold water side
Cold water ball valveBy-pass
Circulation pipeThermostatic mixing valve Material Brass
Dimensions 1"Max. hot water temperature 85 °C
Max. static pressure 10 barOperating pressure 0.2-5 bar
Temperature adjustment range 30-65 °CFlow at 3 bar 57 l/m
Temperature deviation 1.5 °CAnti-scalding protection in compliance with EN1111 and EN1287
Piping Material BrassDimensions 1"
Installation options Wall mountingMounting materials Screws and anchors included in the scope of delivery
TANK ACCESSORIESCIRCULATION UNIT
5
6
7
8
9
1 2 3
4
HW tank HW circulation
Cold water Cold water circulation
1 Shut-oª valve with temperature indicator2 Shut-oª valve with temperature indicator3 Shut-oª valve with thimble (pump on/oª)4 Circulation pump5 KFE-valve (flushing connection, de-aeration)6 Check valve7 Check valve8 Shut-oª valve9 Check valve
Functional diagram
236
TANK ACCESSORIESCIRCULATION UNIT
Pressure drop curves
1
10
100
1. 000
000.001000.01000.100101
1
10
100
1. 000
000.001000.01000.100101
Pressure drop for circulation unitCirculation circuit
Pressure drop for circulation unitHot water circuit
Flow (l/h)
Pres
sure
dro
p (m
bar)
Pres
sure
dro
p (m
bar)
Flow (l/h)
237
TANK ACCESSORIESSLUDGE SEPARATOR FOR HEATING CIRCUITS
MICROBUBBLE DEAERATOR FOR HEATING CIRCUITS
Sludge separator for heating circuitsThe sludge separtor removes sludge particles with dimensions greater than 5 µm from the system water. The captured sludge particles can be rinsed away while the system is in operation. When the drainage tap is opened the accumulated contamination can be quickly pushed out. The ready-to-use insulation has a low thermal conductivity as well as excellent temperature stability and can be easily fitted to the sludge separator by separation along the cutting marks with a cutting knife.
SpecificationsDesignation Sludge separator for heating circuitItem no. 1610604Type SA 64Material BrassConnection (dimension d) G 6/4"Max. operating pressure 10 barMax. temperature 110 °CDimensions H=197 mm, L=88 mmWeight 1.5 kgInsulation EPP hard foam (CFC-free,100% recyclable), H=180 mm, insulation thickness 18 mm, 0.035 W/mK
SpecificationsDesignation Microbubble deaerator for heating circuitsItem no. 1610606Type LA 64Material BrassConnection (dimension d) G 6/4"Max. operating pressure 10 barMax. temperature 110 °CDimensions H=234 mm, L=88 mmWeight 1.6 kgInsulation EPP hard foam (CFC-free,100% recyclable), H=275 mm, insulation thickness 18 mm, 0.035 W/mK
Microbubble deaerator for heating circuitsThe microbubble deaerator has been developed for fully automatic removal of air from water/glycol mixtures (max. 40% glycol). The ready-to-use insulation has a low thermal conductivity as well as excellent temperature stability and can be easily fitted to the micro-bubble deaerator by separation along the cutting marks with a cutting knife.
238
Boiler safety groupBoiler safety group 24 provides optimum protection from exceeding permissible pressures in closed drinking water heaters (TWE), in compli-ance with DIN 1988, part 2; DIN 4753, part 1 and DIN EN 1488. It meets noise protection standards in compliance with DIN 4109 (noise protection in high-rise construction) Class 1 and contains, in compact form, all the components that must be fitted to drinking water heaters as stipulated by DIN 1988 and DIN EN 1488. The pressure relief valve protects the downstream drinking water heater and the return flow inhibitor prevents the heated drinking water from flowing back.
Nominal width DN 20G 3/4"
A 3/4"Unit dimensions L (mm) 205
l (mm) 140H (mm) 100h (mm) 115
Max. nominal volume of the drink-ing water heater (TWE)
(l) 1000
TWE heating power (kW) max. 150
TANK ACCESSORIESBOILER SAFETY GROUP
DVGW Certified DN 20
Specifications
Type BSG 3/4 "
Item no. 1610487
Dimensions DN20
Connection G 3/4"
Input pressure 10 bar in compliance with DIN EN 1488
Operating pressure max. 80% of the pressure relief valve response pressure
Operating temperature max. 30 °C inlet temperature
Response pressure factory-set 6 bar
Component test no. TÜV-SV-05-545-DN-W-p
Installation position any
Flow rate 4.0 m3/h at Δp 1.0 barABP-No. PA-IX 1794/I
DVGW-No DVGW NW-6311AP2713
Pressure relief valve response pressure 6 bar
239
DesignThe safety group consists of a shut-oª valve and a return flow inhibitor with testing device (2 shut-oª valves with DN 20), pressure gauge con-nection and diaphragm pressure relief valve as well as drain funnel with pipe interrupter, which prevents siphoning back of the draining water. The easily exchangeable diaphragm pressure relief valve, with wear-resistant stainless-steel seat, adapts to diªerent installation conditions thanks to a threaded connection that can be turned through 360 degrees. MaterialsAll materials used for the safety group, meet the high requirements of DIN 1988. Plastics and elastomers coming into contact with water con-form to the German plastics and drinking water (KTW) recommendations of the German Public Health Department In particular, all materials are corrosion resistant. Housings, internal components and screw connections are manufactured from high-quality, low-lead brass alloy. The sprung caps of the pressure relief valve are made from glass reinforced plastic, the springs of the pressure relief valve are made from spring steel wire and the return flow inhibitors from stainless-steel.
InstallationThe response pressure of the pressure relief valve may not exceed the permissible operating pressure of the drinking water heater. The di-mensions of the safety group depend on the volume and heating power of the drinking water heaters. The safety group is engaged if the supply pressure does not exceed 80% of the response pressure on the pressure relief valve.
AssemblyThe safety group must always be installed, tension-free, upstream of the drinking water heater, paying attention to the flow direction, in the cold water inlet line which has been well flushed beforehand. The special design of the group makes installation possible with an angle type or straight through type configuration, in horizontal or vertical pipes. The installation is carried out so that no shut-oª valves, filters or narrowing of the pipe are located between the pressure relief valve and the drinking water heater. The fitting should be easily accessible for maintenance and service work. Therefore, the safety group should be arranged above the drinking water heater. This location facilitates straightforward exchange of the pressure relief valve without the necessity of first emptying the drinking water heaters. Should this not be possible, due to the particular installation conditions, then the soldered fittings set (accessories) enables an extension of the connecting pipe to the pressure relief valve.
MaintenanceTo achieve a long operating life for the safety group it is advisable to carry out regular maintenance work in accordance with DIN 1988, part 8. The seat and seals on the pressure relief valve can be cleaned without altering the pressure. Exchange of the stainless-steel seats is equally problem free. The nominal size DN 20 allows replacement of the return flow inhibitors without emptying the drinking water heaters. The component-tested, exchangable pressure relief valve makes replacement possible without dismantling the complete fitting.
Components
1) Integrated pressure relief valve 6 bar
2) Pressure-gauge plug
3) 1. Shut-off valve
4) 2. Shut-off valve
5) Funnel
6) Return flow inhibitor
7) Assembly spanner for exchanging upper part Max. torque 15 Nm
BOILER SAFETY GROUP
TANK ACCESSORIES
240
Boiler safety centreThe boiler centre safeguards closed drinking water heaters, up to a maximum volume of 560 l, in compliance with DIN 1988, part 2; DIN 4753, part 1; DIN 4807, Part 5 and DIN EN 1488. In compliance with DIN 1988 and DIN EN 1488 it contains the components that are required to be fitted to the input side of drinking water heaters. This equipment includes a flow unit with integrated maintenance shut-oª, as well as a compact flow-through membrane expansion tank (MAG) with a nominal volume of 12 l or 18 l, in compact form.
Nominal width – DN 20A G ¾"A1 G 1"
Unit dimensions L (mm) 285h (mm) 80-90 (adjustable)H (mm) 305 (12 litre MAG), 385 (18 litre MAG)
D (mm) 280
TANK ACCESSORIESBOILER SAFETY CENTRE
DVGW Certified
Specifications
Type BCS-12l BCS-18l
Item no. 1610488 1610489
Dimensions DN20
Connection G 3/4"
Inlet pressure 10 bar in compliance with DIN EN 1488
Operating pressure max. 80% of the pressure relief valve response pressure
Operating temperature max. inlet temperature 30 °C
Response pressure 6, 10 bar through enclosed cartridges
Component test no. TÜV-SV-05-545-DN-W-p
Installation position any
Flow rate 1.9 m3/h at 0.2 bar Δp/4.5 m3/h at 1.0 bar ΔpABP-No. PA-IX 7728/I
DVGW-No. NW-6160AT2654
Membrane expansion tank (MAG) 12 litres 18 litres
Pressure relief valve response pressure 6 bar 10 bar
Max. drinking water heater volume 200 l 560 l
241
DesignThe safety centre contains a connection for an additional cold water application, a double shut-oª valve with integrated test capability for the return flow inhibitor, a return flow inhibitor, a pressure relief valve with stainless-steel seat and drain funnel, a flow unit with integrated main-tenance shut-oª valve for the membrane expansion tank as well as a mounting plate with spacer fitting. The special design of the group makes installation possible with an angle type or straight through type configuration, in horizontal or vertical pipes. The diaphragm pressure relief valve adapts to diªerent installation conditions and can be turned through 360°. The mounting plate is designed for safe and rapid installation. The safety centre is tested for sound insulation and meets the requirements of sound insulation class 1.
MaterialsThe housing is made from low lead content, red brass alloy which is resistant to loss of zinc plating. All wearing parts are made from stainless-steel and all pressure bearing plastic parts are made from glass reinforced plastic. Diaphragms and sealing rings are made from heat and ageing resistant plastics with rubber-elastic properties and the springs are wound from corrosion protected spring steel wire and/or rustproof steel. The membrane expansion tank is constructed from coated steel and the membrane of the tank from Nitril rubber NBR. All plastic parts which come into contact with the drinking water meet the German plastics and drinking water (KTW) recommendations of the German Public Health Department.
InstallationThe installation can be carried out either in proximity to the drinking water heaters or in the area where services enter the house. The water supply connection to the building must be fitted with a filter and a pressure reducer. The output pressure adjusted here must not exceed 80% of the response pressure on the pressure relief valve. For wall-mounted installations, the mounting plate provides the required gaps to the wall for the membrane expansion tank as well as the complicated attachment of the membrane expansion tank with the console and mountings. The various installation types make all flow directions possible.
AssemblyBefore assembly, the piping should be carefully flushed. After this the unit should be installed tension-free. A distance of 80 mm to the wall is achieved using the mounting plate supplied. A spacer fitting can be used to adjust this distance between 80 and 95 mm. The drain funnel of the pressure relief valve has a length spacer which can be extended to 20 mm. In place of this funnel, and in order to extend it, it is possible to use a drain line of (22 mm) copper tube.
MaintenanceThe forward gas pressure in the membrane expansion tank must be set 0.2 bar below the static pressure of the installation. To ensure the enduring operation of the safety centre, regular maintenance of the unit's components is required (see DIN 1988, Part 8). Yearly inspection should be performed on the forward pressure of the membrane expansion tank and on the operation of the return flow inhibitor. The pressure relief valve can be cracked open by the turning handle. The sensible construction of the unit allows problem free maintenance or repair of all the individual components.
Components
1) Exchangeable upper part 6 bar 10 bar
2) Niro seat
3) Diaphragm pressure relief valve, complete
4) Pressure-gauge plug
5) Double shut-off valve
6) Assembly spanner for exchanging upper part Max. torque 15 Nm
7) Maintenance cap
8) Return flow inhibitor
9) Plug
10) Membrane expansion tank 12 litres 18 litres
Not illustrated: Drain funnel to the pressure relief valve
BOILER SAFETY CENTRE
TANK ACCESSORIES
242
VM extension sleevefor EHH electric screw-in heating elementFor installation of an electric screw-in heating element in a Pro-Clean®, Pro-Heat or FS tank. EPD-coated.
Boiler thermostat Boiler thermostat for floating switching of an external consumer, installed in a hot water tank with thimble and open/close contact. Control range 30-90 °C.
Specifications
Type BT 210 BT 100
Item no. 1610318 1610320Control unit housing Material synthetic resin
Max. temperature 55 °C (approx.)Protection class IP 40Strain relief provided (cable clip in housing)Dimensions (D x W x H) 45 mm (without control unit button)/55 mm/86 mm
Thimble Material tin-plated copperTotal length 210 mm 100 mmTube length 190 mm 80 mmThread R ½" Spanner size 22Cable inlet rubber grommet
Thermostat Control range 30-90 °CSwitch power 250 V 16 (8) ASwitch power 400 V 16 (4) A Terminal clamps 3 pieces using (enclosed) screwsSensor capillary tube sensor 300 mm Contact 1 opener and 1 closer
Specifications
Type VM
Item no. 1610609
Material S 235 JR
EXTENSION SLEEVE
BOILER THERMOSTAT
TANK ACCESSORIES
Thimble
Hex head screw, spanner size 22
Cable inlet
243
Impressed current anode Unless preventive measures are taken, the constant introduction of oxygen-rich fresh water into your hot water tank inevitably causes the tank to corrode. Traditionally, two types of protective measures are used. The first is an inner coating, but that means that extremely small areas will be unprotected. The second is the use of a magnesium anode, which pro-duces a complementary protective current. But the anode "sacrifices" itself over time. When it is used up, there is no protective current for the tank – and corrosion sets in.
An impressed current anode is a long-term alternative to a sacrificial anode. It is based on the most advanced technology and provides a lasting, electronically controlled protective current for your tank. The continuous protective current is controlled by a potentiostat and is supplied by a titanium electrode in the tank. This provides safe protec-tion against corrosion in all TiSUN® enamelled steel tanks.
An eªective protective current must be adjusted exactly to the indi-vidual conditions in the hot water tank at all times. To prevent it from
being too high or too low, the potentiostat automatically adjusts the current based on the individual operating conditions. Over- or under-protection is prevented in this manner. The current is fed via a mixed oxide coated titanium electrode, which is practically wear-free.
Measurement and feeding procedures take place alternately within millisecond intervals:1. Measurement of the actual potential in the tank 2. Calculation of the current required to reach the target potential 3. Feeding the protective current 4. Achieving the target potentialCorrosion can therefore not commence.
The impressed current anode is supplied with all components required for installation. The potentiostat and electrode are easily connected to one another using a connecting cable. The accessories supplied al-low very quick push-fit assembly.
TroubleshootingThe troubleshooting procedures described below may only be carried out by the installer or a qualified service technician!
If neither of the indicator lights is lit, there is probably no mains voltage.• Is the tank's water heater filled with water? Fill the tank's water heater with
water.• Are you sure that the flow of electricity in the circuit is uninterrupted?
Check all connections and switches to be sure that they are making proper metallic, electrical-conducting contact and rectify the fault.
• Is the polarity correct? Test the voltage – connect a digital multimetre with the anode (positive pole) and tank (negative pole). It has to show a positive value.
• Is a magnesium anode still installed in the tank water heater? Remove the magnesium anode.• Is the electrode completely insulated from the tank wall and components
installed in the tank? When the tank is empty, use a tester to check the in-sulation. If necessary, correct the position of the components and/or the electrode.
• Are the seals wet? Remove the anode, dry all parts and reinstall. Make sure that the installation is insulated.
• Have any non-enamelled heat exchangers (e.g. Cu finned tubes, Cu smooth pipes or CrNi smooth pipes) been installed so that they are completely elec-trically insulated against the tank water heater? Check the insulation with a tester and rectify any fault.
• Is the plug-in potentiostat overloaded? Inspect the container for visible enamelling faults.
If the impressed current anode fault cannot be corrected with these proce-dures, please contact our customer service department. The fact that the LEDs are lit green does not necessarily mean that the tank is protected. This only shows that the protective current is present. The size of the anode must be appropriate for the tank in order for the anode to oªer su�cient cathodic pro-tection.
Specifications
Type FA-S1
Item no. 1610064Use for enamelled tanks up to 1000 lPotentiostat - Type UP 19Version Plug-in potentiostatMains voltage 230 VFrequency 50/60 HzNominal current 100 mAPermissible ambient temperature 0-40 °CProtection class IP IIConnection male thread G ¾"
General information The assembly specifications are non-binding guideline values that only serve for orientation and assume that the tanks are manufactured according to DIN 4753. It is especially important to meet the specifications prescribed for the quality of the enamel (standard protective current requirement). Tanks have to be made of non-rusting steel containing a minimum of 16% chromium. Any additional metallic components installed in the tanks (heat exchangers, electric heating elements, etc.) have to be insulated and equipped with an electrical potential balancing resistor if necessary. If several anodes are installed, they must be evenly distributed within the tank. The tank height/width ratio may not exceed 3:1. Binding approval of any additional installations requires prior laboratory tank measurements by Norsk Hydro.
TANK ACCESSORIESS1 IMPRESSED CURRENT ANODE
NOTES