TITAN SERIES - Maser Australia · INTRODUCING TITAN Temperature-tolerant Titan transforms the...

17
TITAN SERIES LED UTILITY LIGHTING Transform the toughest environments into smarter spaces with Titan.

Transcript of TITAN SERIES - Maser Australia · INTRODUCING TITAN Temperature-tolerant Titan transforms the...

Page 1: TITAN SERIES - Maser Australia · INTRODUCING TITAN Temperature-tolerant Titan transforms the toughest spaces: car parks, cold rooms, warehouses, workshops and more. Attractive and

TITAN SERIESLED UTILITY LIGHTING

Transform the toughest environments into smarter spaces with Titan.

Page 2: TITAN SERIES - Maser Australia · INTRODUCING TITAN Temperature-tolerant Titan transforms the toughest spaces: car parks, cold rooms, warehouses, workshops and more. Attractive and

INTRODUCING TITAN

Temperature-tolerant Titan transforms the toughest spaces: car parks, cold rooms, warehouses, workshops and more. Attractive and highly durable fixtures deliver smooth and controllable light, enhancing safety, ambience and profitability. Energy savings of 70% and tripled fixture lifetimes give you rapid payback and dramatic cost-reduction for years to come.

SMART DESIGN

SMART CONTROL

APPLICATION KNOW-HOW

ACCELERATED PAYBACK

+

3

Page 3: TITAN SERIES - Maser Australia · INTRODUCING TITAN Temperature-tolerant Titan transforms the toughest spaces: car parks, cold rooms, warehouses, workshops and more. Attractive and

5

WATERPROOF IP66

Every Titan model is rated IP66 for protection against water. Silicon seals inside the fixture prevent moisture penetration. Unlike rubber,

silicon seals do not perish; they last the lifetime of the lighting fixture.

A specially designed expansion joint compensates for varying coefficients of

expansion in housing and diffusor materials, guaranteeing the integrity of seals.

IMPACT RESISTANT IK08

Titan is built from polycarbonate, making it extremely robust. The IK08 rating indicates excellent resistance to external impacts, on a standard scale of 1 to 10.

Titan is also tamper-proof. Locking screws in the end caps protect against theft and vandalism in public spaces.

EXTREME AMBIENT TEMPERATURES

Titan ensures immediate and consistent light in temperatures from -20°c to +40°c, for reliability and safety in the most demanding environments. Options for higher ambient temperatures are available on request. Light is switched on right away, regardless of cold or heat.

BUILT FOR THE TOUGHEST SPACES

4

Page 4: TITAN SERIES - Maser Australia · INTRODUCING TITAN Temperature-tolerant Titan transforms the toughest spaces: car parks, cold rooms, warehouses, workshops and more. Attractive and

6 7

Titan uses the latest tier 1 LED chips for the best colour consistency, longest life and efficacy.

Primary optics from LED are often inefficient, losing 30% of overall light output. Nualight’s optical designs use the best available primary optic, engineered for best optical diffusion and retaining high light output, for smooth primary light across a broader area.

Titan’s diffusor is engineered for optimal light distribution. The diffusor distributes the lighting into a narrow beam, wide beam or batwing angle embracing the widest possible range of applications and spaces.

SMOOTH LIGHTING BY DESIGN

Titan’s unique optical design delivers very high uniformity (typically above 0.5) while eliminating uncomfortable glare. In fact, Titan carries a low glare value as part of its specification.

Ultra-smooth lighting on target, that is the Titan difference. The unique optical design of Titan eliminates glare while efficiently distributing light without wastage. The result? A lean lighting solution that is also exceptionally comfortable.

One of the reasons why Titan is so efficient is the light distribution of the fixture. Many lighting manufacturers only offer one optic for fixtures similar to Titan, but Nualight offers three different optics to offer an optimum solution for all applications. This significantly reduces light wastage because light is only distributed to where it is needed.

HIGHEST QUALITY LED TECHNOLOGY

SUPERB EFFICIENCY

MULTIPLE APPLICATIONS LIGHT ON TARGET

HIGHER UNIFORMITY AND LOWER GLARE

Page 5: TITAN SERIES - Maser Australia · INTRODUCING TITAN Temperature-tolerant Titan transforms the toughest spaces: car parks, cold rooms, warehouses, workshops and more. Attractive and

8 9

GOOD FOR

THE PLANET

AND YOUR BUSINESS

With energy costs projected to rise together with public demandfor a responsible corporate approach to sustainability, LED is the only truly viable choice for lighting today and into the future. Energy savings of up to 90% (with smart controls) compared to fluorescent, combine with longer life for cost reductions of over 80% and more.

A Titan LED solution will lower the lighting installation’s carbon footprint by 70%, earning valuable financial

incentives in some countries.

63%ENERGY SAVINGS

WITHOUT CONTROLS

36% ENERGY SAVINGS

WITHOUT CONTROLS

42%ENERGY SAVINGS

OVERALL

UP TO 90%ENERGY SAVINGS

WITH CONTROLS

36-65%ENERGY SAVINGS

WITHOUT CONTROLS

42%ENERGY SAVINGS

OVERALL

70%ENERGY SAVINGS

UP TO

LOWER CARBON FOOTPRINT

ENERGY SAVINGS

Page 6: TITAN SERIES - Maser Australia · INTRODUCING TITAN Temperature-tolerant Titan transforms the toughest spaces: car parks, cold rooms, warehouses, workshops and more. Attractive and

10

WHAT IS DALI?

Digital Addressable Lighting Interface, or DALI, is a worldwide standard enabling the allocation of a digital address to every LED fixture. It facilitates digital lighting, with every fixture individually and remotely controllable. In the near future it will allow LED to evolve beyond lighting. Each fixture will be connected and capable of passing and receiving information. The applications are almost limitless.

THE DALI DIFFERENCE

An investment in Titan is a future-proofed investment as DALI comes as standard with every Titan fixture.

Today, this means that Titan can be easily dimmed in response to motion, proximity and available daylight, in a very smooth and user-friendly way.

WHY IS DALI IMPORTANT?

DALI-enabled LED will increasingly give competitive advantage. It will become much more than lighting. Connected digital components will be able to respond to changing conditions, gathering data, reporting conditions and driving intelligent responses across a range of connected technologies. Considering DALI today will enable future-proofed Smarter Spaces tomorrow.

CREATE SMARTER SPACES WITH NEXT GENERATION LIGHTING CONTROLS

ENERGY SAVINGS

WITHOUT CONTROLS

ENERGY SAVINGS

WITHOUT CONTROLS

ENERGY SAVINGS

OVERALL

UP TO 90%ENERGY SAVINGS

SMART CONTROLS

UP TO 60%ENERGY SAVINGS

WITHOUT CONTROLS

UP TO 70%ENERGY SAVINGS

SIMPLECONTROLS

70%ENERGY SAVINGS

ENERGY SAVINGS

WITHOUT CONTROLS

ENERGY SAVINGS

WITHOUT CONTROLS

ENERGY SAVINGS

OVERALL

UP TO 90%ENERGY SAVINGS

SMART CONTROLS

UP TO 60%ENERGY SAVINGS

WITHOUT CONTROLS

UP TO 70%ENERGY SAVINGS

SIMPLECONTROLS

70%ENERGY SAVINGS

ENERGY SAVINGS

WITHOUT CONTROLS

ENERGY SAVINGS

WITHOUT CONTROLS

ENERGY SAVINGS

OVERALL

UP TO 90%ENERGY SAVINGS

SMART CONTROLS

UP TO 60%ENERGY SAVINGS

WITHOUT CONTROLS

UP TO 70%ENERGY SAVINGS

SIMPLECONTROLS

70%ENERGY SAVINGS

Even without smart controls, replacing fluorescent with Titan will typically yield energy savings of 60%.

When relamping costs are eliminated, the business case becomes even brighter over the guaranteed 50,000 hour lifetime of this quality product.

A reduced labour cost in retrofit projects due to Titan’s rapid toolless installation design further improves the payback relative to other LED solutions.

Simple on-off controls together with daylight harvesting will typically deliver 70% energy savings in situations where DALI is neither feasible nor necessary.

Optimised sensor technology and configuration is key and Nualight advises partners and end-users on how to achieve maximum energy savings while maintaining the best possible lighting experience.

SOPHISTICATED CONTROL WITH DALI

Titan offers DALI control as standard, bringing unlimited possibilities in terms of precision zonal control.

With DALI, energy savings of 90% can be achieved however there is also an enhanced user experience factor.

DALI technology allows the lighting to be dimmed in a very smooth way that is barely perceptible, creating a very comfortable experience.

SIMPLE BUT SMARTUPGRADING TO TITAN

11

Page 7: TITAN SERIES - Maser Australia · INTRODUCING TITAN Temperature-tolerant Titan transforms the toughest spaces: car parks, cold rooms, warehouses, workshops and more. Attractive and

APPLICATION EXAMPLE: WORKSHOP

BENEFITS

• Bright and uniform working space with Titan• Low glare providing comfort and an enhanced working

atmosphere• Instant on and off switching, no start-up time• No more maintenance

63%ENERGY SAVINGS

WITHOUT CONTROLS

47% ENERGY SAVINGS

WITHOUT CONTROLS

42%ENERGY SAVINGS

OVERALL

UP TO 80%ENERGY SAVINGS

WITH CONTROLS

47-60%ENERGY SAVINGS

WITHOUT CONTROLS

42%ENERGY SAVINGS

OVERALL

70%ENERGY SAVINGS

UP TO

MEETING THE CHALLENGEBRIGHT AMBIENT LIGHTING FOR A PRODUCTIVE WORKING ATMOSPHERE

Workshops require bright and uniform lighting. Good lighting in workshops is crucial, especially in demanding situations requiring a high degree of concentration. With the right lighting people will feel active, focused and happier at work. In fact, studies have shown that it enhances overall productivity.

12

63%ENERGY SAVINGS

WITHOUT CONTROLS

47% ENERGY SAVINGS

WITHOUT CONTROLS

42%ENERGY SAVINGS

OVERALL

UP TO 80%ENERGY SAVINGS

WITH CONTROLS

47-60%ENERGY SAVINGS

WITHOUT CONTROLS

42%ENERGY SAVINGS

OVERALL

70%ENERGY SAVINGS

UP TO

UPGRADING TO TITAN

For this example a batwing optic was used. The batwing is used for low to mid high ceilings that require a very wide light distribution. The beam angle of this optic is 147 degrees.

RETROFIT EXAMPLE

The illustrations below show a comparison between fluorescent lighting and Titan. A typical workshop layout was used and the fixtures were replaced on a like-for-like basis.

SPECIFICATIONS

floor surface 250 m2

fixtures used 40mounting height 4.5 metersspacing between fixtures 3.1 m (x-axis) 2.10 m (y-axis)

T8 FLUORESCENT T5 FLUORESCENT TITAN LED

LIGHT SOURCE T8 T5 TITAN LED

Fixture power consumption (incl. ballast) 128 W 108 W 68 WLifetime 10,000 20,000 50,000+Overall lux level on workplane (0,8 m) 516 lx 606 lx 505 lxUniformity (Egem) 0.68 0,676 0.634UGR >25 >25 <25Overall power consumption per m2 20.48 W/m2 17.28 W/m2 10.88 W/m2

REQUIREMENTS

EN 12464-1 sub 2.19.1Working plane (on + 0.8 m): 500 luxUGR < 22Ra > 80

13

LIFETIMECOMPARISON

X 5

Smart dimming can make a big difference to energy consumption when lighting workshops with Titan.

For large workshops with specific zones and possibly even showroom or storage areas, Titan’s integrated DALI driver makes zonal dimming cost-effective and easy to deploy.

SMART CONTROLS FOR FASTER PAYBACK

WIDE RANGE OF ENERGY SAVINGS

There are many variables that determine actual energy savings: type of incumbent technology, condition of existing lighting and overlighting to compensate for lifetime light degradation will all have an impact. The range of energy savings shown on this application page are for guideline purposes only.

Page 8: TITAN SERIES - Maser Australia · INTRODUCING TITAN Temperature-tolerant Titan transforms the toughest spaces: car parks, cold rooms, warehouses, workshops and more. Attractive and

Warehouse environments need effective and robust lighting. Temperature fluctuations and the risk of collisions call for durability. Shelving and racking, with deep shadowed spaces, need lighting to be as bright and uniform as possible for safety and usability. Titan’s uniformity both in horizontal and vertical illuminance delivers bright, consistent light. Robust construction and temperature-tolerance mean exceptional reliability. Titan’s low glare is safe and comfortable even for upward-oriented tasks.

BENEFITS• Narrow beam-angle for high ceilings • Polycarbonate impact-resistant fixture • Good upward visibility due to high levels of vertical

illuminance together with low glare• Fluctuating ambient temperatures do not effect the 50,000

hour lifetime and performance

MEETING THE CHALLENGEHIGH CEILINGS AND FLUCTUATING AMBIENT TEMPERATURES

63%ENERGY SAVINGS

WITHOUT CONTROLS

47% ENERGY SAVINGS

WITHOUT CONTROLS

42%ENERGY SAVINGS

OVERALL

UP TO 80%ENERGY SAVINGS

WITH CONTROLS

47-60%ENERGY SAVINGS

WITHOUT CONTROLS

42%ENERGY SAVINGS

OVERALL

70%ENERGY SAVINGS

UP TO

APPLICATION EXAMPLE: WAREHOUSE

14

63%ENERGY SAVINGS

WITHOUT CONTROLS

47% ENERGY SAVINGS

WITHOUT CONTROLS

42%ENERGY SAVINGS

OVERALL

UP TO 80%ENERGY SAVINGS

WITH CONTROLS

47-60%ENERGY SAVINGS

WITHOUT CONTROLS

42%ENERGY SAVINGS

OVERALL

70%ENERGY SAVINGS

UP TO

UPGRADING TO TITAN

For this example a narrow beam optic was used. The narrow beam optic is ideal in situations with high ceilings, requiring a substantial amount of light on the floor. The lighting is distributed in a beam not wider than 80 degrees.

RETROFIT COMPARISON

The illustrations below show a comparison between fluorescent lighting and Titan. A typical warehouse layout was used and the fixtures were replaced on a like-for-like basis.

SPECIFICATIONS

floor surface 1163 m2

fixtures used 70mounting height 6.5 mspacing between fixtures 3.3 m

T8 FLUORESCENT T5 FLUORESCENT TITAN LED

LIGHT SOURCE T8 T5 TITAN LEDFixture power consumption (incl. ballast) 128 W 108 W 68 WLifetime 10,000 20,000 50,000+Overall lux level on floor-level 99 lx 106 lx 110 xHorizontal between racking floor-level / uniformity 134 lx / 0.83 142 lx / 0.95 170 lx / 0.88 Vertical on racking / uniformity 117 lx / 0.4 128 lx / 0.4 99 lx / 0.53UGR > 25 > 25 < 25Overall power consumption per m2 7.70 W/m2 6.50 W/m2 4.09 W/m2

REQUIREMENTS

EN 12464-1 sub 1.5.2Working plane on floor-level: 100 luxUGR < 22Ra > 60

Warehouses can experience zones with long periods of inactivity. In retrofit applications, Titan can be easily equipped with daylight harvesting and simple on-off controls which will dramatically reduce costs and are easily deployed even in older buildings. For more sophisticated environments with multiple uses which may require different levels of lighting, DALI control allows precise zonal control and user-friendly dimming.

15

LIFETIMECOMPARISON

X 5

WIDE RANGE OF ENERGY SAVINGS

SMART CONTROLS FOR FASTER PAYBACK

There are many variables that determine actual energy savings: type of incumbent technology, condition of existing lighting and overlighting to compensate for lifetime light degradation will all have an impact. The range of energy savings shown on this application page are for guideline purposes only.

Page 9: TITAN SERIES - Maser Australia · INTRODUCING TITAN Temperature-tolerant Titan transforms the toughest spaces: car parks, cold rooms, warehouses, workshops and more. Attractive and

Car park success is directly impacted by lighting. A safe and welcoming car park increases loyalty and even occupancy, while lower energy costs have a tremendous impact on profitability.

Nualight is an expert in car park lighting and Titan was designed specifically for covered car parks with the objective of outperforming the industry in terms of very fresh and smooth lighting with exceptional uniformity and industry-leading efficiency.

Titan’s design for rapid installation also minimises retrofit labour costs.

BENEFITS• Superb uniformity for enhanced safety• Fresh, comfortable, glare-free lighting• DALI driver as standard for cost-effective smart controls• Extremely fast toolless installation in retrofit projects

MEETING THE CHALLENGE ENHANCED COMFORT AND SAFETY

63%ENERGY SAVINGS

WITHOUT CONTROLS

36% ENERGY SAVINGS

WITHOUT CONTROLS

42%ENERGY SAVINGS

OVERALL

UP TO 90%ENERGY SAVINGS

WITH CONTROLS

36-65%ENERGY SAVINGS

WITHOUT CONTROLS

42%ENERGY SAVINGS

OVERALL

70%ENERGY SAVINGS

UP TO

APPLICATION EXAMPLE: PARKING

16

63%ENERGY SAVINGS

WITHOUT CONTROLS

36% ENERGY SAVINGS

WITHOUT CONTROLS

42%ENERGY SAVINGS

OVERALL

UP TO 90%ENERGY SAVINGS

WITH CONTROLS

36-65%ENERGY SAVINGS

WITHOUT CONTROLS

42%ENERGY SAVINGS

OVERALL

70%ENERGY SAVINGS

UP TO

UPGRADING TO TITAN

For this example a batwing optic was used. The batwing is used for low to mid high ceilings that require a very wide light distribution. The beam angle of this optic is 147 degrees.

RETROFIT COMPARISON

The illustrations below show a comparison between fluorescent lighting and Titan. A typical car park layout was used and the fixtures were replaced on a like-for-like basis.

SPECIFICATIONS

floor surface 9967 m2

fixtures used 255mounting height 2.8 metersspacing between fixtures 4.53 m

T8 FLUORESCENT T5 FLUORESCENT TITAN LED

29 t

LIGHT SOURCE T8 T5 TITAN LEDFixture power consumption (incl. ballast) 64 W (+ 18 x 128 W) 54 W (+ 18 x 108 W) 42 W (+ 18 x 68 W)Lifetime 10,000 20,000 50,000+Overall lux level on 0.8 m 89 lx 92 lx 98 lxLux level entrance floor-level / uniformity 346 lx / 0.89 375 lx / 0.89 309 lx / 0.83Lux level driving aisles + parking places 78 lx / 0.65 68 lx / 0.67 84 lx / 0.58floor-level / uniformity Lux level counter/cash working-plane (0.8 m) 262 lx 281 lx 300 lxUGR > 25 > 25 < 25Overall power consumption per m2 1.75 W/m2 1.48 W/m2 1.12 W/m2

REQUIREMENTS

EN 12464-1 sub 5.7Entrance: 300 Lux on floor-level (at daytime)Driving aisles: 75 lux on floor-levelParking places: 75 lux on floor-levelCounters/cash: 300 lux on working-plane (+ 0.8 m)

Simple on-off control systems, together with daylight harvesting, can deliver dramatic energy savings but must be carefully configured using optimum sensor technology and a clear vision for the desired customer experience.

DALI offers the added advantage of an improved customer experience as the lighting is more precisely controlled across the various zones in a car park and can be gradually dimmed up and down. A DALI driver is standard with every Titan fixture.

17

LIFETIMECOMPARISON

X 5

WIDE RANGE OF ENERGY SAVINGS

SMART CONTROLS FOR FASTER PAYBACK

There are many variables that determine actual energy savings: type of incumbent technology, condition of existing lighting and overlighting to compensate for lifetime light degradation will all have an impact. The range of energy savings shown on this application page are for guideline purposes only.

Page 10: TITAN SERIES - Maser Australia · INTRODUCING TITAN Temperature-tolerant Titan transforms the toughest spaces: car parks, cold rooms, warehouses, workshops and more. Attractive and

19

Coldrooms are characterised by low temperaturesand increased humidity, meaning that effective lighting must be sealed against moisture and be designed to withstand cold environments.

Lighting in coldrooms is only needed for a portionof the time during daily operation, making itan ideal application for dramatic energy savings with smart controls. Unlike fluorescent technology, Titan LED delivers 100% lighting instantly without fail.

BENEFITS

• Moisture-proof• Specified for low ambient temperature up to -20• 100 % lighting instantly, without fail• Smart on/off controls save significant energy

MEETING THE CHALLENGEEFFICIENCY IN LOW TEMPERATURES

70%ENERGY SAVINGS

WITH CONTROLS

35% ENERGY SAVINGS

WITHOUT CONTROLS

42%ENERGY SAVINGS

OVERALL

70%ENERGY SAVINGS

WITH CONTROLS

35-55%ENERGY SAVINGS

WITHOUT CONTROLS

42%ENERGY SAVINGS

OVERALL

70%ENERGY SAVINGS

UP TO

APPLICATION EXAMPLE: COLDROOMS

18

70%ENERGY SAVINGS

WITH CONTROLS

35% ENERGY SAVINGS

WITHOUT CONTROLS

42%ENERGY SAVINGS

OVERALL

70%ENERGY SAVINGS

WITH CONTROLS

35-55%ENERGY SAVINGS

WITHOUT CONTROLS

42%ENERGY SAVINGS

OVERALL

70%ENERGY SAVINGS

UP TO

UPGRADING TO TITAN

For this project example a wide-beam optic was used. The wide beam is an all-round optic that is used for low to mid high ceilings that require a very uniform light distribution. Light is evenly spread in a beam angle of 160º.

RETROFIT COMPARISON

The illustrations below show a comparison between fluorescent lighting and Titan. A typical coldroom layout was used and the fixtures were replaced on a like-for-like basis.

floor surface 100 m2

fixtures used 4mounting height 2.8 metersspacing between fixtures 5 m

T8 FLUORESCENT T5 FLUORESCENT TITAN LED

LIGHT SOURCE T8 T5 TITAN LEDFixture power consumption (incl. ballast) 64 W 54 W 42 WLifetime 10,000 20,000 50,000+Overall lux level on work-plane (0.8 m) 127 lx 105 lx 117 lxUniformity 0.511 0.511 0.467UGR > 25 > 25 < 25Overall power consumption per m2 2.56 W/m2 2.16 W/m2 1.68 W/m2

EN 12464-1 sub 1.4.1. (storage)Working-plane (on + 0.8 m): 100 luxUGR < 25Ra > 60

REQUIREMENTS SPECIFICATIONS

WIDE RANGE OF ENERGY SAVINGS

LIFETIMECOMPARISON

X 5

Smart on/off controls can save significant energy in coldroom applications. Unlike fluorescent, Titan LED can be relied on to switch on instantly, without fail. This instant light, together with a very long guaranteed lifetime of 50,000 hours, creates a highly efficient solution and a low total lifetime cost.

LIFETIMECOMPARISON

X 5

SMART CONTROLS FOR FASTER PAYBACK

There are many variables that determine actual energy savings: type of incumbent technology, condition of existing lighting and overlighting to compensate for lifetime light degradation will all have an impact. The range of energy savings shown on this application page are for guideline purposes only.

Page 11: TITAN SERIES - Maser Australia · INTRODUCING TITAN Temperature-tolerant Titan transforms the toughest spaces: car parks, cold rooms, warehouses, workshops and more. Attractive and

20

Because spaces vary so widely in size, environment and application, the Titan series offers a choice of 3 optics (narrow, wide and batwing), 3 lengths and 2 light colours.

Another Titan option is an integrated emergency lighting function with a battery back-up of 3 hours. This means that extra wiring and lighting systems to indicate the emergency route are no longer necessary. Every luminaire operates autonomously. A built-in power LED in the end of the fixture switches on when the power fails.

Titan 1500 mm

Titan 1100 mm

Titan 650 mm

CHOOSE YOUR TITAN

LENGTHS

EMERGENCY LIGHT OPTION

COLOURTEMPERATURES

OPTICS

A choice of tailored optics ensures optimised performance for a range of applications.

4000K

5000K

BATWING

Car park garagesWorkshops

NARROW BEAM

WarehousesProduction halls

WIDE BEAM

Car park garagesWorkshopsPublic transport hubsColdrooms

This colour temperature is standard for most applications. People refer to it as neutral white colour and it provides a very clear and comfortable lighting atmosphere.

In some applications a more intense white is desirable. Studies have shown that there is a relationship between light colour and productivity. In hotter climates whiter lighting is used to simulate coolness and cleanliness.

21

TRACK MOUNTED OPTION

It is possible to mount the Titan in a multi phase track with an optional kit.

Page 12: TITAN SERIES - Maser Australia · INTRODUCING TITAN Temperature-tolerant Titan transforms the toughest spaces: car parks, cold rooms, warehouses, workshops and more. Attractive and

22 23

TIME IS MONEY!

Time is money. Titan can be installed very rapidly leading to significant savings in labour costs on projects. The Nualight team can replace a fluorescent fixture with Titan in less than 4 minutes, can you?

FLEXIBLE INSTALLATION

Our fixtures are designed with numerous entry points for cabling, allowing for multiple wiring configurations without compromising watertight seals. Retrofit projects and new builds alike are always able to connect the fixture quickly.

Standard

Loop through

Top entry

Ceiling entry

Emergency light

INSTALLATION IN LESS THAN 5 MINUTES PER FIXTURE

Page 13: TITAN SERIES - Maser Australia · INTRODUCING TITAN Temperature-tolerant Titan transforms the toughest spaces: car parks, cold rooms, warehouses, workshops and more. Attractive and

24

As the parent company of Lumotech, Nualight benefits from added expertise in drivers, bringing an extra dimension to its controls know-how. Lumotech has 35 years of experience in specialist LED controls, sensor technology and control gear.

RELIABILITY & PERFORMANCE

BEST-IN-CLASS DALI DRIVER

The LED driver is vital to the overall performance of each LED fixture. The Lumotech LED driver inside each Titan is engineered and manufactured in Europe and comes with a 5 year warranty. It delivers exceptional standards of control and is acknowledged as

the very best in its class.

FIVE YEAR WARRANTY

Each Titan is backed by a 5-year warranty on the entire fixture: the LEDs, the optics and the

control gear. Titan only features components that are precisely measured and selected, so users

know the fixture will deliver long-term reliable performance.

EUROPEAN DESIGN AND MANUFACTURE

Nualight has R&D facilities and manufacturing in Europe. Our LED drivers and luminaires undergo stringent testing. Performance is measured throughout the lifetime of fixtures, with focus on efficiency, power, harmonics and inrush current.

LOW INRUSH CURRENT

Titan’s Lumotech driver keeps inrush current very low. When fluorescent lighting switches on, an instant peak in current causes a spike in energy consumption and can trip circuit breakers. Low to zero inrush current with Titan LED allows many more fixtures to be installed on each circuit breaker, so it is not necessary to make any changes to the electrical system.

25

Page 14: TITAN SERIES - Maser Australia · INTRODUCING TITAN Temperature-tolerant Titan transforms the toughest spaces: car parks, cold rooms, warehouses, workshops and more. Attractive and

27

TITAN SPECIFICATIONS

min. 150

30 30

30

min. 150

min. 150

min. 150

1500 mm (42 - 68W)650 mm (14W) 1100 mm (28W)

350 - 800 - 1200

800 - 1200

1500 mm (42 - 68W)1100 mm (28W)

TITAN 600

Power consumption: 14 W Colour temperature: 4000K / 5000KLuminous flux (lm): 1300 lmLuminous efficacy (lm/W): 93 lm/WPower factor: 0.98LED lifetime: 50,000 hrs / 70%CRI: 84 UGR: <25 Control: DALI dimmableAmbient temperature (Ta)*: -20˚C to +40˚C Beam angle: Wide beam 160˚

Classifications: IP66, IK08 Case dimensions (WxHxD): 650 x 105 x 92 mmCase material: Polycarbonate Case colours: Grey

Emergency versionoperating hours: 180 min.Power consumption: 2 WLuminous flux (lm): 129 lm

* Titan models for higher ambient temperatures are available on request.

TITAN 1200 28 W 4000K / 5000K2600 lm93 lm/W0.9850,000 hrs / 70%84 <25 DALI dimmable-20˚C to +40˚C Wide beam 160˚

IP66, IK08 1100 x 105 x 92 mmPolycarbonate Grey

180 min. 2 W129 lm

TITAN 1500

42 W / 68 W4000K / 5000K4000 lm / 5700 lm95 lm/W / 85 lm/W0.9850,000 hrs / 70%84 <25 DALI dimmable-20˚C to +40˚C Narrow beam 83˚Wide beam 160˚ Batwing 147˚ IP66, IK08 1500 x 105 x 92 mm Polycarbonate Grey

180 min. 2 W129 lm

106 mm

26

ORDERING INFORMATION

Product type Wiring Emergency Colour temp. Article No. Order No.

TITAN 1500

Titan 1500mm 42W batwing 4000 lm Standard No 4000K Ti150-39-BW-40N-S L020000

Titan 1500mm 42W batwing 4000 lm Daisy chain No 4000K Ti150-39-BW-40N-D L020001

Titan 1500mm 42W batwing 4000 lm Standard Yes 4000K Ti150-39-BW-40EM-S L020002

Titan 1500mm 42W batwing 4000 lm Daisy chain Yes 4000K Ti150-39-BW-40EM-D L020003

Titan 1500mm 42W narrow beam 4000 lm Standard No 4000K Ti150-39-NB-40N-S L020008

Titan 1500mm 42W narrow beam 4000 lm Daisy chain No 4000K Ti150-39-NB-40N-D L020009

Titan 1500mm 42W narrow beam 4000 lm Standard Yes 4000K Ti 150-39-NB-40EM-S L020010

Titan 1500mm 42W narrow beam 4000 lm Daisy chain Yes 4000K Ti 150-39-NB-40EM-D L020011

Titan 1500mm 42W wide beam 4000 lm Standard No 4000K Ti150-39-WB-40N-S L020016

Titan 1500mm 42W wide beam 4000 lm Daisy chain No 4000K Ti150-39-WB-40N-D L020017

Titan 1500mm 42W wide beam 4000 lm Standard Yes 4000K Ti150-39-WB-40EM-S L020018

Titan 1500mm 42W wide beam 4000 lm Daisy chain Yes 4000K Ti150-39-WB-40EM-D L020019

Titan 1500mm 68W batwing 5700 lm Standard No 4000K Ti150-57-BW-40N-S L020024

Titan 1500mm 68W batwing 5700 lm Daisy chain No 4000K Ti150-57-BW-40N-D L020025

Titan 1500mm 68W batwing 5700 lm Standard Yes 4000K Ti150-57-BW-40EM-S L020026

Titan 1500mm 68W batwing 5700 lm Daisy chain Yes 4000K Ti150-57-BW-40EM-D L020027

Titan 1500mm 68W narrow beam 5700 lm Standard No 4000K Ti150-57-NB-40N-S L020032

Titan 1500mm 68W narrow beam 5700 lm Daisy chain No 4000K Ti150-57-NB-40N-D L020033

Titan 1500mm 68W narrow beam 5700 lm Standard Yes 4000K Ti150-57-NB-40EM-S L020034

Titan 1500mm 68W narrow beam 5700 lm Daisy chain Yes 4000K Ti150-57-NB-40EM-D L020035

Titan 1500mm 68W wide beam 5700 lm Standard No 4000K Ti150-57-WB-40N-S L020040

Titan 1500mm 68W wide beam 5700 lm Daisy chain No 4000K Ti150-57-WB-40N-D L020041

Titan 1500mm 68W wide beam 5700 lm Standard Yes 4000K Ti150-57-WB-40EM-S L020042

Titan 1500mm 68W wide beam 5700 lm Daisy chain Yes 4000K Ti150-57-WB-40EM-D L020043

TITAN 1200

Titan 1200mm 28W wide beam 2600 lm Standard No 4000K Ti120-26-WB-40N-S L020048

Titan 1200mm 28W wide beam 2600 lm Daisy chain No 4000K Ti120-26-WB-40N-D L020049

Titan 1200mm 28W wide beam 2600 lm Standard Yes 4000K Ti120-26-WB-40EM-S L020050

Titan 1200mm 28W wide beam 2600 lm Daisy chain Yes 4000K Ti120-26-WB-40EM-D L020051

TITAN 600

Titan 600mm 14W wide beam 1300 lm Standard No 4000K Ti60-13-WB-40N-S L020056

Titan 600mm 14W wide beam 1300 lm Daisy chain Yes 4000K Ti60-13-WB-40EM-S L020057

ACCESSORIESTitan track mount kit A01010

* All Titans are available in 5000K colour temperature on request

Page 15: TITAN SERIES - Maser Australia · INTRODUCING TITAN Temperature-tolerant Titan transforms the toughest spaces: car parks, cold rooms, warehouses, workshops and more. Attractive and

YOUR GUARANTEE OF QUALITY

Titan comes with the reassurance of rigorous certifications. Your investment in Titan is protected by our guarantees and tight adherence to European and British safety standards. Titan is fully ENEC compliant and each luminaire is backed by a 5 year warranty.

Nualight is a game-changing LED lighting technology company and one of the top LED specialists in Europe. We focus on retail, commercial and industrial market segments where application know-how and smart controls dramatically improve results from LED. Our vision is to create Smarter Spaces through LED innovation.

Lumoluce b.v. Nijverheidsplein 16NL-1704 RB HeerhugowaardThe Netherlands

[email protected] +31 (0)72 572 30 00F +31 (0)72 572 30 30www.lumoluce.com

LUMOLUCE IS PART OF THENUALIGHT GROUPwww.nualightgroup.com

Declaration of ConformityEC - DIRECTIVES

We, Lumotech Holland b.v., hereby declare that the product(s) from Lumotech and Lumoluce listed below is/are in conformity with the relevant provision(s) of the directive(s), as well as pertinent clause(s) of the standard(s) and/or other specifications/document(s) mentioned on this page.

Heerhugowaard, January 2014 A. Cronin General Manager

Product: Titan

Trade name(s): Lumotech, Lumoluce

Directive(s) • Electromagnetic Compatibility Directive (EMC), 2004/108/EC • Low Voltage Directive (LVD), 2006/95/EC • RoHS Directive, 2002/95/EC • REACH Directive, 2006/121/EC

Standard(s)Luminaire (including driver) EMC EN 55015: 2006 +A1: 2007 +A2: 2009 EN 61000-3-2: 2006 +A1: 2007 +A2: 2009 EN 61547: 2009 EN 60598-2-22 (Emergency version)

LVD EN 60598-1: 2009 EN 60598-2-1: 1979 + A1: 1987 EN 62031: 2008 EN 62471: 2008

DriverLVD EN 61347-2-13: 2006 EN 61347-1: 2008 EN 62384: 2006

Reference(s) and normative document(s)Specifications: see Datasheets on www.lumoluce.comManual : see Manuals on www.lumoluce.com

28

CONTACT INFO

EUROPE

Nualight EuropeCork Business ParkModel Farm RoadCorkIrelandT: +353 21 4867 636

NETHERLANDS

Nualight NetherlandsNijverheidsplein 161704 RB HeerhugowaardNederlandT: +31 72 572 3000

UK

Nualight UKCork Business ParkModel Farm RoadCorkIrelandT: +353 21 4867 636

SWITZERLAND

Nualight SchweizOffice 253Hardturmstrasse 2538005 ZurichSchweizT: +41 (0)79 179 69 11

GERMANY

Nualight GermanyFlössaustrasse 88A90763FürthDeutschlandT: +49 911 971 6188

For Nualight partners and distributors across the world, visit www.nualight.com

TRUST IN THE NUALIGHT BRAND

Page 16: TITAN SERIES - Maser Australia · INTRODUCING TITAN Temperature-tolerant Titan transforms the toughest spaces: car parks, cold rooms, warehouses, workshops and more. Attractive and
Page 17: TITAN SERIES - Maser Australia · INTRODUCING TITAN Temperature-tolerant Titan transforms the toughest spaces: car parks, cold rooms, warehouses, workshops and more. Attractive and

©2014, Nualight Ltd. All rights reserved. Designs and specifications may change without prior notice.

10092014_v2