TITAN M6-72

download TITAN M6-72

of 2

Transcript of TITAN M6-72

  • 7/27/2019 TITAN M6-72

    1/2

    Typical Electrical Characteristics

    Type TITAN M6-72Max Power Pmp (W) 275 280 285

    Power Tolerance (W) +0 to 4.9Wp or 2.5%

    Max Power Voltage Vmp(V) 35.04 35.18 36.12

    Max Power Current Imp (A) 7.85 7.96 8.03

    Open Circuit Voltage Voc (V) 43.99 44.28 44.78

    Short Circuit Current Isc (A) 8.39 8.46 8.53

    Max System Voltage VDC 1000

    Number, type and arrangement of cells 72, Multi-Crystalline, 12 x 6 Matrix

    Cell Size 6 x 6 / 156 x 156 mm

    No. of By-pass Diodes 3

    Max Series Fuse (A) 15

    Pm Temperature Co-efficient () (%/C) -0.41

    Isc Temperature Co-efficient () (%/C) +0.04

    Voc Temperature Co-efficient () (%/C) -0.32

    NOCT at STC (C) 451

    Mechanical Characteristics

    Junction Box Tyco / ZJRH / Huber + Suhner

    Type of connector Tyco / MC4

    Dimensions (L x W x Th) mm 1975 x 988 x 50

    Weight Kg 27.0

    No. of Drain Holes in Frame 12Glass Type and Thickness 4 mm Thick, Low iron, Tempered

    Packing Configuration

    Packing Configuration 20 Modules in each pallet

    1 * 20 Ft 200 Modules

    1 * 40 Ft STD/HQ 400 modules

    Absolute Ratings

    Operating Temperature (C) -40 ~ +85

    Storage Temperature (C) -40 ~ +85

    PV Module TITAN M6-72

    Product Guarantee : 5 years

    Limited Power Warranty : 90% @ 12 Years

    80% @ 25 Years

    High Efficiency PV Modules

    35.63

    8.00

    44.42

    8.49

    290265

    34.33

    7.72

    43.27

    8.30

    Titan Energy Systems La member of SARSA g

    An ISO 9001:2008 Certified Com

    Strengths

    Positive power tolerance

    High Efficiency Multi Crystalline Modules

    TUV Certifications:

    Withstands heavy loading due to snow & ice;

    Has higher safety margin for storm weather

    and gale winds

    NOTE: The data presented may change due to further improvements in the product.

    Certifications

    Electrical parameters tolerance 5%

    EN IEC 61215 : 2005

    EN IEC 61730-1 : 2004 / 2007EN IEC 61730-2 : 2004 / 2007

    36.51

    8.08

    45.00

    8.56

    295

    36.72

    8.17

    45.50

    8.65

    300

    36

    8

    45

    8

    3270

    34.75

    7.77

    43.70

    8.34

    EN IEC 61701 : 2010-02

    Qualified for Highly corrosive Wet-

    Atmospheres & Environments

  • 7/27/2019 TITAN M6-72

    2/2

    PV Module TITAN M6-72

    Dimensions

    PV Module Products

    M6-72 Family Series (305Wp to 125Wp) : M6-72, M6-60, M6-54 & M6-36 - Certified for IEC Standards

    S6-60 Family Series (250Wp to 120Wp) : S6-60, S6-54 & S6-36 - Certified for IEC Standards

    S6-60 - Certified for UL (USA & Canada) Standard

    S5-96 Family Series (250Wp to 75Wp) : S5-96, S5-72, S5-60, S5-54 & S5-36 - Certified for IEC Standards

    M6-60: Certified for UL (USA & Canada) Standard; M6-72: Certification for UL (USA & Canada) is in Prog

    S6-72 Family Series (300Wp to 285Wp) : Certification for IEC & UL (USA & Canada) Standards

    www.titan-energy.com

    TITAN Energy Systems Ltd,

    16, Aruna Enclave, Trimulgherry,

    Secunderabad 500 015, INDIA

    Phone: +91 (0)40 27791085, 27790751

    Fax: +91 (0)40 27795629

    Email: [email protected]

    Corporate Office (India) :TITAN Energy Systems Ltd,

    Basel, 4052

    Switzerland

    Phone: +41-6150-0052-9

    Email: [email protected]

    Sales Office (Europe) :

    50+0.5 mm

    DATA Label

    Warning Label

    Terminal Box

    100+1mm

    592+1mm

    591+1mm

    592+1mm

    100+1mm

    4 Sq mm Cable, 1Mtr Length

    with Connectors

    3.9 mm EARTHING

    HOLES - 2 nos

    100+1 mm

    237.5+1 mm

    375+1 mm

    REAR VIEW

    988+1mm

    943.5+1 mm

    8X12- MOUNTING

    SLOTS - 10 nos

    4.5mm DRAIN HOLES -12 nos

    Embossed

    Earth Symbol

    100+1mm

    375+1 mm

    1975 1 mm

    FRONT VIEW

    (One on each long member)

    (5 on each long member)

    FRAME

    SIDE RAIL

    988 1 mm

    1975 1mm

    Sl.No.Label

    Typical I-V Curves

    Current/voltage dependence on irradiance and module temperature.These I-V curves indicate the effect of temperature and light intensity on module Performance.

    1000 W/m at 25 C2 O1000 W /m at 25 CO

    800 W/m at 25 C2 O800 W/m at 25 CO

    600 W/m at 25 C

    2 O

    600 W /m at 25 CO

    400 W/m at 25 C2 O400 W /m at 25 CO

    200 W/m at 25 C2 O200 W /m at 25 CO

    CueA)

    10.0

    8.0

    6.0

    4.0

    2.0

    0.0 10.0

    1000 W/m at 50 C2 O1000 W /m at 50 CO

    Voltage (V)20.0 30.0 40.0 50.0