Timber - SIG Insulation Literature.pdf · in accordance with BS6399: ... Eurofox systems are all...

8

Transcript of Timber - SIG Insulation Literature.pdf · in accordance with BS6399: ... Eurofox systems are all...

Timber

Aluminium Composite

l Aluminium ‘Hybrid’ systems allow Timber Cladding to be used but with all the advantages of Aluminium back frames being adopted

Featuring MUK-va-100

2

Rainscreen support systemsFIbre Cement/Fibre Concrete Ceramic/Thin Stone

Terracotta/Brick Slip Render

Å 01707 333 396

Featuring MLZ/k-v-00 Featuring XLP-v-300

Featuring XLP-v-400 Featuring MTA-v-300

3

Metal

e Material (ACM) High Pressure Laminate (HPL)

Featuring MLA-v-100

Featuring MTK-va-100

www.eurofoxengineering.com

l Please note: Codes highlighted in Red above are featured in this brochureFor the full range refer to ‘A Structured Approach to Facades’ - Available on request

Visible Fix Concealed Fix Concealed Fix Eurofox / TimberMechanical Structural Bond Hybrid

Rivet Profile SikaTack MacUNIClamps Anchor

Timber MUH-v-100Metal MLA-v-100 MLA-v-570 MUH-v-200

XLA-h-100 MLA-v-400XLA-h-100

Aluminium MUK-va-100 MTK-v-900Composite (ACM) MTA-v-400 MYH-v-900

MTA-v-900MYA-v-900

Fibre Cement / MTA-v-100 MLV-k-v-20 MTK-v-100 MWH-h-100High Pressure MLZ-v-500 MLZ/k-v-00 XLP-v-300

laminate (HPL) XLZ-h-100 XLP-v-300Fibre Concrete

Ceramic / MTC-v-300 MLV/k-v-20 MTK-v-100Thin Stone MTC-v-100 MLZ/k-v-00

XLC-h-350 XLP-v-300

Terracotta XLP-v-400MTS-v-400MTS-v-500MTS-v-700MTS-v-710XLT-v-100XLS-h-400

Render MUH-v-600

Helping handsFor Eurofox the ‘helping hands’ ethos covers many aspects of your business from getting the rightproduct in the right place at the right time to the introduction to our Eurofox partners includingappropriate installers, facade manufacturers and trade associations

4 Å 01707 333 396

l Helpful Sales support staff will be able to assist with current stock availability and price information. Immediate stock allocation is available to get a project underway and to ensure its smooth running

l We hold extensive stocks of brackets, components and extrusions

l We offer a prompt efficient delivery service, accurately picked, clearly identified whenever and wherever required

www.rainscreenworks.com

AutoCAD

l We can introduce you to specialist facade installers/enveloping contractors selected by geographical location, project scope and size

l We offer comprehensive technical support - available as AutoCAD files, method statements, and as animations. All Eurofox support systems are available as NBS Plus Specification Clauses

l Partnerships are important. Based upon significant international and domestic experience we can introduce you to original facade manufacturers - Market leaders who have adopted Eurofox as their support system of choice

Vertical fixing

Horizontal fixing

1 Clipped Connection, adjust

For initial line and level adjustment theEUROFOX profiles are clipped into theMacFOX-brackets

3 MacFOX – fixed point

The vertical profile is fixed to theMacFOX support bracket by screwsthrough the round holes. TheMacFOX bracket absorbs bothvertical dead loads and horizontalwind loads

5 Structural systemvertical fixing

Each vertical profile is fixed to oneMacFOX fixed point and a number ofMacFOX flexible point brackets. As aconsequence of thermal expansion, thelength of the profiles normally does notexceed the storey height. The bracketspacing is determined by claddingoptions such as the dimensions andweight of the facade cladding, windloads and cladding zone

Eurofox systems are fully adjustable in 1 mm increments from 40 mm - 340 mm

4 MacFOX – flexiblepoint

Screws fixed through theelongated holes connect thevertical profile to the MacFOXbracket. Consequently, thermalexpansion is not constrained bythe support system. The MacFOXflexible point bracket absorbswindloads only

6 Clipped connection, adjustFor initial line and level adjustment the Eurofox profiles areclipped into the XFox brackets

7 Final fixingAfter adjustment the profiles are fixed to the XFOX-bracketswith screws. Round holes and elongated holes in the XFOX-brackets allow the creation of both, fixed points (FP) andflexible points (GP)

2 Final Fixing After adjustment the EUROFOX profilesare fixed to the MacFOX-brackets withscrews. Round holes and elongatedholes in the MacFOX-brackets allow forthe creation of both, fixed points (FP)and flexible fixing points (GP)

Installation vertical fixing

Installation horizontal fixing

1

3

4

6 7

5

2

www.eurofoxengineering.com 5

6 Å 01707 333 396

Our approach to facadesVisible Fix Concealed Fix Concealed Fix Eurofox / Timber

Mechanical Structural Bond Hybrid

Timber l l l 3

Metal 3 3 l 3

Aluminium Composite (ACM) 3 l 3 l

Fibre Cement / 3 3 3 3

High Pressure laminate (HPL) 3 3 3 3

Fibre Concrete 3 3 3 l

Ceramic / Thin Stone 3 3 3 l

Terracotta l 3 l l

Render l l l 3?The dimensional location of the brackets is dependant upon the type offacade / facade weight / building location / cladding zone (normally in-corporating insulation and a ventilation cavity), structural design factorsin accordance with BS6399: Parts 1 & 2 : 1977 - Code of practice for dead,imposed and wind loadings for buildings

l Eurofox Aluminium Rainscreen cladding support systems have been developed to service the ever changing face of facade design and the Architects / Engineers demands for more flexible and economical cladding solutions and are suitable for New Build / Renovation - Steel / Concrete / SIPS substructure - up to any height

l Modern Rainscreen support systems need to maintain quality and offer excellent technical performance - We offer advanced vertical and horizontal support systems, utilising both mechanical fix and structural adhesive techniques for visible and concealed construction

l Eurofox systems are available for facades ranging from lightweight panels to 70 + kg/m2 cladding elements

l Eurofox facade ventilated rainscreen systems incorporate extruded aluminium fully adjustable ‘helping hand’ support bracket and rail systems, and include Eurofox isolator pads to mitigate cold bridging

l Cladding zones from 40 - 340 mm can be accommodated. This versatility provides the designer with an almost infinite range of facade appearances and layout options, each of which must be safely engineered

At Eurofox we believe that cladding is a serious business. Eurofox offer a support service for the safe and optimised setting out of Rainscreen bracket components, rails and grid systems. The structural requirements of the back framing system can be calculated to ensure the integrity of the installation. Project material quantities can be accurately estimated and potential cost savings identified

Eurofox can provide static calculations and setting out information for the components and rails that will be required to support the chosen facade. Each calculation is ‘project specific’ and will reflect the engineering intent of the scheme e.g. panel weight / cladding zone / building height and the architectural intent e.g. panel layout

Straightforward access is provided via completion of the ‘Project Checklist’ via www.eurofoxengineering.com

Eurofox systems are all produced in European facilities and aremanufactured using appropriate alloys - Systems have been tested in the UK at BRE and Taylor Woodrow facilities

Design Matters- Static calculations- Specification writing assistance- AutoCAD - Layout advice- Method statements

7www.eurofoxengineering.com

Visible Fix Concealed Fix Concealed Fix Eurofox / TimberMechanical Structural Bond Hybrid

mber l l l 3

Metal 3 3 l 3

ACM) 3 l 3 l

ent / 3 3 3 3

(HPL) 3 3 3 3

crete 3 3 3 l

Stone 3 3 3 l

cotta l 3 l l

ender l l l 3

Legends:

location of the brackets is dependant upon the type ofweight / building location / cladding zone (normally in-

ation and a ventilation cavity), structural design factorsth BS6399: Parts 1 & 2 : 1977 - Code of practice for dead,

nd loadings for buildings

m1

EUROFOX Engineering LTDUnit 10 Blenheim Court Brownfields - Welwyn Garden CityHERTS AL7 1AD Tel: +44 (0)1707 333 396, Fax: +44 (0)1707 333 343

E-Mail: [email protected]