tiles installation final - rmc-marble.eu

31
TILES INSTALLATION

Transcript of tiles installation final - rmc-marble.eu

Page 1: tiles installation final - rmc-marble.eu

TILESINSTALLATION

Page 2: tiles installation final - rmc-marble.eu

Consists of chemical products selected, tested and manufactured to provide excellentperformance especially for RMC and engineered quartz products. Developed and guaranteedby Eurosurfaces, manufactured in Czech Republic.

• Penetration primer

• Contact bridge

• Waterproofing products

• Adhesives

• Grouts

• Impregnation

• Cleaningagent

BASEPR EPAR ATION INSTALLATION MAINTENANCE

Page 3: tiles installation final - rmc-marble.eu

Basecharacteristics:

• Concretescreedwithamaximumresidualmoisture4,5%

• Anhydritescreed,dryandroughened,witharesidualmoisture0,5%andincaseoffloorheating0,3%

ForbasepreparationuseproductsformEurosurfacesChemicalSystem:

• PENETRATIONPRIMER|P1– absorbentbase

• CONTACTBRIDGE|CB1– non-absorbentbase(e.g.oldstonetiles,metalbase)

• WATERPROOFING|WP1– notpermanentcontactwithwater(bathroom)

• WATERPROOFING|WP2– permanentcontactwithwater(showers,pools,terraces)

• SEALINGTAPE|WP3

BASEPR EPAR ATION

Page 4: tiles installation final - rmc-marble.eu

penetration• Before a priming of the base with PENETRATION PRIMER | P1, it is necessary to clean it properly(a priming is used to unify the absorbency of the base and a subsequent maturation of anadhesive during installation)

• Penetration primer is applied with a roller or a brush in 1:5 ratio (concentrate : water), usage0,10 L / sqm

• Usage

BASEPR EPAR ATION

Page 5: tiles installation final - rmc-marble.eu

contactbridge

• In case of a non-absorbent base (e.g. existing tiles from engineered marble or quartz,glass, ceramics, metal), use a contact bridge instead of penetration primer.

• A coating with CONTACT BRIDGE | CB1 generates a strong bonding between a non-absorbent substrate and applied adhesive.

• It is suitable for both internal and external environments.

• Usage 0,25 kg / sqm

BASEPR EPAR ATION

Page 6: tiles installation final - rmc-marble.eu

waterproofing

In wet areas (bathrooms, wellness, pools, terraces, balconies), it is necessary to treat thebase with waterproofing

• For bathrooms and areas where isolation is NOT permanently in contact with water

• Use liquid WATERPROOFING | WP1 in 24 kg package – direct application (1,20 kg /sqm / 2 layers) – 2 layers are recommended

• For areas permanently in contact with water (wellness, public bathrooms, terraces,balconies, pools, showers)

• Use WATERPROOFING | WP2 in 20kg package, which has to be mixed with water(1,5 kg/1 sqm/1 layer in 1 mm) – 2 or 3 layers are recommended

• For waterproofing of construction dilatation and into contacts wall x wall and wall x floor

• Use elastic SEALING TAPE | WP3 (see following photo instructions, how to use)

BASEPR EPAR ATION

Page 7: tiles installation final - rmc-marble.eu

waterproofing/WP1

LiquidWATERPROOFING|WP1shouldbeappliedintwolayerswitharolleroratrowelontothebase.

BASEPR EPAR ATION

Page 8: tiles installation final - rmc-marble.eu

waterproofing/WP2

WATERPROOFING | WP2 should be applied only with trowel and also in 2 layers (for pools3 layers).

BASEPR EPAR ATION

Page 9: tiles installation final - rmc-marble.eu

waterproofing/sealingtape

Applicationofsealingtapeintoliquidwaterproofing.

BASEPR EPAR ATION

Page 10: tiles installation final - rmc-marble.eu

measurement

Measurealayingproperly(patterndrawing)andrespectfullyaconstructiondilatationinthebase.

BASEPR EPAR ATION

Page 11: tiles installation final - rmc-marble.eu

Forinstallation,werecommendtousefollowingproductsfromEurosurfacesChemicalSystem:

• ADHESIVE|A1– availableingreyandwhite

• GROUT|G1– flexibleandhighlywaterresistant

INSTALLATION

Page 12: tiles installation final - rmc-marble.eu

INSTALLATION

adhesivemixing

Use ADHESIVE | A1 in grey or white:

• Grey – granularity 0 – 0,7 mm

• White– granularity0– 0,4mm

Mix adhesive into the right consistency

• Follow instructions on packaging regardingvolume of water

• Use a slow speed rotation for mixing adhesiveand keep pause 5 minutes before application

Page 13: tiles installation final - rmc-marble.eu

INSTALLATION

adhesiveapplication

DOUBLE COATING

• To achieve the best performance of installedRMC engineered marble or Technistoneengineered quartz tiles, it is required to usedouble coating.

• Kindly consider this process as the only correctoption for tiles installation.

Page 14: tiles installation final - rmc-marble.eu

adhesiveapplicationAdhesiveapplicationonthebase

• Useatrowelwithasizeoftooth10x10mm

INSTALLATION

Page 15: tiles installation final - rmc-marble.eu

INSTALLATION

adhesiveapplication

Adhesive application onto the back of the tile

Gluing tiles using BUTTERING – FLOATINGmethod

• An adhesive application with flat side of trowelonto tiles (during gluing it achieves maximalcontact between a tile and a base)

Page 16: tiles installation final - rmc-marble.eu

tileslaying• Press or tap tiles and balance them with surroundings, joints are recommended to be inwidth of 2 - 4 mm and depth of 3 mm.

• Tap on each tile using a rubber hammer to help adhesive to be spread evenly on a backside of tile.

INSTALLATION

Page 17: tiles installation final - rmc-marble.eu

Anyadhesiveexcessmustbeimmediatelyremovedwithadampclothorasponge• Removebothinthejointsandonthesidesofthetiles• JointshavetobecleanandtohaveaspaceforgroutTilesarewalkablein24hours.Fullloadin7days.

tiles layingINSTALLATION

Page 18: tiles installation final - rmc-marble.eu

grouting• After maturation of the adhesive (3 - 4 days, depending on temperature and relativehumidity), joints can be filled with grout in selected colour.

• Follow instructions for mixing GROUT | G1 with water – 1 kg : 0,22-0,26 L of water

INSTALLATION

Page 19: tiles installation final - rmc-marble.eu

grouting• Afterlettingthegroutslightlydry,starttowashtheexcesseswithsponge.

• Thegroundisfullydriedin7days.

INSTALLATION

Page 20: tiles installation final - rmc-marble.eu

Duringalayingofbig-formattiles,itisimportanttofollowinstructionsfordilatationjoints

• Constructiondilatationinbasemustbealwaysfollowed.

INSTALLATION

dilatation

Page 21: tiles installation final - rmc-marble.eu

• It is necessary to keep intermediate dilatations between tiles.

• Do that with flexible silicone sealant or by insertion of dilatation stripe - it is necessary touse material with neutral pH.

• The optimum size of the dilatation field is recommended to be 3x3 m.

• Clean a joint from the adhesive – use only neutral cleaning products.

• Perimeterdilatationshouldbedonearoundtheroom,contactsbetweenfloorxwallandwallxwall.

dilatation

Neutral silicone

Separation cord

INSTALLATION

Page 22: tiles installation final - rmc-marble.eu

• Cleandilatationjointfromtheadhesive.

• Insertseparationcord– itassuresarightfunctionofdilatationandpreventtearingofsilicone.

• Werecommendtocoverbothsidesofjointwithcovertape– tomakeeasieranapplicationofsilicone.

dilatation

INSTALLATION

Page 23: tiles installation final - rmc-marble.eu

• Filljointwithsiliconandshapeitwithspatula.

• Finalsmoothingofsiliconeisdonebywaterandatoolinrequiredshape.

dilatation

INSTALLATION

Page 24: tiles installation final - rmc-marble.eu

Formaintenance,werecommendtousefollowingproductsfromEurosurfacesChemicalSystem:

• IMPREGNATION|IM1

• CLEANINGAGENT|CA1

MAINTENANCE

Page 25: tiles installation final - rmc-marble.eu

MAINTENANCE

impregnation

• After thorough cleaning of dirt after laying,we recommend to treat the surface withimpregnation IMPREGNATION | IM1

• It provides easier cleaning of tileswithout any change of surface shade.

• It makes much easier also a removingof graffiti or dirt on facades.

• We recommend to impregnate surface onregular base:

• Public areas – once a year

• Private spaces – once per 5 – 10 years

• Façades – once per 10 years or more

Page 26: tiles installation final - rmc-marble.eu

MAINTENANCE

It is important to do regular maintenance ofthe laid tiles

• For general cleaning, use CLEANING AGENT| CA1 in concentration of 40 ml with 10 L ofwater

• It is possible to use it also for machinecleaning

• It doesn‘t remove an applied impregnation

Only neutral cleaning products arerecommended.

• As with natural stone floorings, abrasive,acids or products containing soluble saltslike sulphate or chloride should not be usedfor maintenance.

cleaning

Page 27: tiles installation final - rmc-marble.eu

• Incaseofdamage(orglossloss)ofthesurfaceoffloortilesitispossibletorenewthesurfacebyre-polishingorredoinghoned.

• Theglossofthesurfaceisreturnedtonew.

• Thisoperationcanbecarriedoutonlybyexperienced,specializedcompanieswithappropriateequipment.Itisalwaysnecessarytotesttherenewalfirst,possiblyonasmall,unexposedarea.

• Themethodusedisthesamecarriedoutonnaturalmarbleusingdisplaceablepolishingmachines.

re-polishingMAINTENANCE

Page 28: tiles installation final - rmc-marble.eu

ADDITIONALIMPOR TANTINFOR MATION

Page 29: tiles installation final - rmc-marble.eu

BESTPRACTICES

Toachievethebestperformancewerecommendfollowing:

• Iftheareaoftileisbiggerthan0,7sqm,atileshouldbeinthicknessof20mmormore.

• Incaseofbushhammeredandsatinsurfaceonreferenceswithbigstones(RMCOriginalcollection),tilesshouldbeinthicknessof20mmormore.

• Tilesontoexternalandinternalwallsfromheight2,4mshouldbefixedmechanically,notchemically.

• Blackcolours,especiallypolishedsurface,aren’tgenerallysuitableforflooring;itisbettertoinstallhonedoragedsurface.

• Forreferencessuitableforexternalapplication,kindlycontactoursalesrepresentative.

Page 30: tiles installation final - rmc-marble.eu

RECOMMENDEDTOOLSFORINSTALLATION

Square-notchtrowel

• Themostcommonlyused

• Insizesof10x10or8x8mm

K-notchtrowel,height10mm

• Nickednamed“Velcro”

• Aperfectadhesiontothebackofthetile

Spongetrowel

Spatula

Etc.

Page 31: tiles installation final - rmc-marble.eu

EUROSURFACESPORTUGALS.A.Rua Correia daCoutinha Nr.1,P.O.Box303771-909OliveiradoBairroPortugal

www.eurosurfaces.eu

T:+351(234)740400F:+351(234)740401

KINDLYCONTACTUSFORMOREINFORMATION