ThyssenKrupp Electrical Steel India

11
Theme : NABL Testing Date 26.03.2015 Speaker : Kapil Kapoor (+919765557057) 1 ThyssenKrupp Electrical Steel India ThyssenKrupp Electrical Steel India Home of Testing Laboratory ThyssenKrupp Electrical Steel India

Transcript of ThyssenKrupp Electrical Steel India

Page 1: ThyssenKrupp Electrical Steel India

Theme : NABL TestingDate 26.03.2015Speaker : Kapil Kapoor (+91 9765557057)1 ThyssenKrupp Electrical Steel India

ThyssenKrupp Electrical Steel IndiaHome of

Testing Laboratory

ThyssenKrupp Electrical Steel India

Page 2: ThyssenKrupp Electrical Steel India

Theme : NABL TestingDate 26.03.2015Speaker : Kapil Kapoor (+91 9765557057)2 ThyssenKrupp Electrical Steel India

TKES, India – Strategically Located Plant in Western Region

Nashik, Maharashtra, IndiaNearest Airport: Mumbai about 155 Km / Nashik about 55 KmNearest Railway Station: Nashik about 30 Km / Igatpuri about 20 Km

Delhi

Kolkata

Mumbai

TKES India

Chennai

Page 3: ThyssenKrupp Electrical Steel India

Theme : NABL TestingDate 26.03.2015Speaker : Kapil Kapoor (+91 9765557057)3 ThyssenKrupp Electrical Steel India

ThyssenKrupp Electrical Steel India Testing Laboratory

• Testing Experience of More than 40 Years

• Wealth of experience in the field of Testing

• International Bench Marking in Field of Testing

• Continuous up gradation of our Equipments & services

• Representation in Standard bodies at National / International Level

Accredited in the field of

ElectricalMechanicalChemical

Page 4: ThyssenKrupp Electrical Steel India

Theme : NABL TestingDate 26.03.2015Speaker : Kapil Kapoor (+91 9765557057)4 ThyssenKrupp Electrical Steel India

ThyssenKrupp Electrical Steel India Testing Laboratory

• Core Loss Measurement • A.C. Magnetisation

• Permeability

• Anisotropy

• Aging test

• Coating Thickness

• Insulation resistivity

• Stacking Factor

• Coating Adherence

• Thermal Effect on coating

• Resistance to Solvents & Oils

• Sheet Thickness

• Ductility

Electrical Testing

Page 5: ThyssenKrupp Electrical Steel India

Theme : NABL TestingDate 26.03.2015Speaker : Kapil Kapoor (+91 9765557057)5 ThyssenKrupp Electrical Steel India

ThyssenKrupp Electrical Steel India Testing Laboratory

• Yield strength

• Tensile Strength

• % Elongation

• Rockwell Hardness - HRB

• Rockwell Hardness – HR 30 T

• Vickers Hardness - VPN

Mechanical Testing

Page 6: ThyssenKrupp Electrical Steel India

Theme : NABL TestingDate 26.03.2015Speaker : Kapil Kapoor (+91 9765557057)6 ThyssenKrupp Electrical Steel India

ThyssenKrupp Electrical Steel India Testing Laboratory

• Manganese in Steel

• Silicon in Steel

• Aluminium in Steel

• Phosphorus in Steel

• Copper in Steel

• Chromium in Steel

• Nickel in Steel

• Carbon in Steel

• Sulphur in Steel

• Purity of Copper Wire

Chemical Testing

Page 7: ThyssenKrupp Electrical Steel India

Theme : NABL TestingDate 26.03.2015Speaker : Kapil Kapoor (+91 9765557057)7 ThyssenKrupp Electrical Steel India

ThyssenKrupp Electrical Steel India Testing Laboratory Accreditation & Certification • Ensures testing in accordance with National & International standards.

• Enhances Customer confidence and Satisfaction.

• National & International acceptability of test results.

• Provides Confidence

• Ensures Independence

• Ensures Repeatability and Reproducibility

Page 8: ThyssenKrupp Electrical Steel India

Theme : NABL TestingDate 26.03.2015Speaker : Kapil Kapoor (+91 9765557057)8 ThyssenKrupp Electrical Steel India

ThyssenKrupp Electrical Steel India Testing Laboratory Sample Information

TestSample

Thickness in mm

Minimum

Nos.

Sample Dimension in mm

Magnetic Test by Epstein Method> 0.65 < 2.00 12 *T x 30 x 305 / 280

(minimum weight must be greater than 400gms)

> 0.35 < 0.65 16> 0.20 < 0.35 32

Magnetic Test by Single Sheet Method 0.20-1.00 1 Tx500x500

YS, TS, % Elongation UTM - Dumbell Sample T 2 20 x 210 , radius (20)

Hardness (HRB , HRC , VPN) T 2 T X 20 x 20Ductility T 10** T X 30 x 152Insulation & Coating test T 12 T X 50 x 125Stacking Factor T > 1 kg T X 30 x 245Chemical Testing (Spectro Analysis) T 2 25 x100% C & % S (Leco Analysis) T 5 gm 10 mm x 10 mmCopper Purity - > 50 gms -*T- Thickness of specimen , ** - 5 Rolling & 5 Transverse direction

Page 9: ThyssenKrupp Electrical Steel India

Theme : NABL TestingDate 26.03.2015Speaker : Kapil Kapoor (+91 9765557057)9 ThyssenKrupp Electrical Steel India

ThyssenKrupp Electrical Steel India Testing Laboratory Sample recommendation• In case of Non-Oriented half of the samples in the rolling direction and other half in

the Transverse direction. • In case of Grain Oriented all samples are in rolling direction

• Samples are always needed in multiple of 4 for Epstein Testing .

• Care should be practiced to exclude any bent, twisted, dented, highly burred, or improperly sheared strips from the test specimen.

• Samples should be drawn from OD of coil , discarding 2 wraps.

• Insulation resistivity : Width and length of a specimen strip shall be greater than the width and length respectively of the assembly of contacts.

Sampling recommendation for Insulation resistivity

Sampling recommendation for Epstein

W

L

Page 10: ThyssenKrupp Electrical Steel India

Theme : NABL TestingDate 26.03.2015Speaker : Kapil Kapoor (+91 9765557057)10 ThyssenKrupp Electrical Steel India

ThyssenKrupp Electrical Steel India Testing Laboratory - Customers

Page 11: ThyssenKrupp Electrical Steel India

Theme : NABL TestingDate 26.03.2015Speaker : Kapil Kapoor (+91 9765557057)11 ThyssenKrupp Electrical Steel India

Kapil KapoorEmail : [email protected] : +91-9765557057

Thank you for your kind attention…..