THPWAS only THP I-THP Cambi own IP Typical application Intensive digestion for new builds and sludge...
-
Upload
alan-phillips -
Category
Documents
-
view
217 -
download
0
Transcript of THPWAS only THP I-THP Cambi own IP Typical application Intensive digestion for new builds and sludge...
![Page 1: THPWAS only THP I-THP Cambi own IP Typical application Intensive digestion for new builds and sludge centres Partial intensification / class B sludge.](https://reader035.fdocuments.net/reader035/viewer/2022081516/56649cf75503460f949c6f48/html5/thumbnails/1.jpg)
![Page 2: THPWAS only THP I-THP Cambi own IP Typical application Intensive digestion for new builds and sludge centres Partial intensification / class B sludge.](https://reader035.fdocuments.net/reader035/viewer/2022081516/56649cf75503460f949c6f48/html5/thumbnails/2.jpg)
![Page 3: THPWAS only THP I-THP Cambi own IP Typical application Intensive digestion for new builds and sludge centres Partial intensification / class B sludge.](https://reader035.fdocuments.net/reader035/viewer/2022081516/56649cf75503460f949c6f48/html5/thumbnails/3.jpg)
![Page 4: THPWAS only THP I-THP Cambi own IP Typical application Intensive digestion for new builds and sludge centres Partial intensification / class B sludge.](https://reader035.fdocuments.net/reader035/viewer/2022081516/56649cf75503460f949c6f48/html5/thumbnails/4.jpg)
![Page 5: THPWAS only THP I-THP Cambi own IP Typical application Intensive digestion for new builds and sludge centres Partial intensification / class B sludge.](https://reader035.fdocuments.net/reader035/viewer/2022081516/56649cf75503460f949c6f48/html5/thumbnails/5.jpg)
THP WAS only THP I-THPCambi own IP
Typical application Intensive digestion for new builds and sludge centres
Partial intensification / class B sludge
Lazy existing digester capacity, Class A cake,
Increased energy production
VS loading <8 kgVS/m3/d< 621 lb.VS/1,000 ft3
3-5 kgVS/m3/d233-388 lb.VS/1,000 ft3
3-4 kgVS/m3/day233-311 lb.VS/1,000 ft3
Energy balance >80% of biogas to CHP 100% on waste heat 100% on waste heat
THP size 100% ~50% ~60%
Typical %DS of cake 30-45% 25-40% 34-50%
Typical VSR 52-65% 52-60% 60-70%
Electrical Output (MWh/TDS) 0.97 0.90 1.07
Operational / in construction 40 3 1 (pilot)
![Page 6: THPWAS only THP I-THP Cambi own IP Typical application Intensive digestion for new builds and sludge centres Partial intensification / class B sludge.](https://reader035.fdocuments.net/reader035/viewer/2022081516/56649cf75503460f949c6f48/html5/thumbnails/6.jpg)
![Page 7: THPWAS only THP I-THP Cambi own IP Typical application Intensive digestion for new builds and sludge centres Partial intensification / class B sludge.](https://reader035.fdocuments.net/reader035/viewer/2022081516/56649cf75503460f949c6f48/html5/thumbnails/7.jpg)
Cambi Solidstream® Technology
BiogasFinal
dewatering
(no polymer)100°
C
Sludge cake
> 60% DS
Pre dewatering
Reject water to
main WWTP
Thickened
Sludge
5% DS
Conventional
digester
45% VSR
SolidStream®
Hydrolysate (soluble COD) to digester
CHPElectricity
+ 15 – 30% gas from
THP hydrolysate
17% DS
Steam
< 500 kg/tonDS
![Page 8: THPWAS only THP I-THP Cambi own IP Typical application Intensive digestion for new builds and sludge centres Partial intensification / class B sludge.](https://reader035.fdocuments.net/reader035/viewer/2022081516/56649cf75503460f949c6f48/html5/thumbnails/8.jpg)
![Page 9: THPWAS only THP I-THP Cambi own IP Typical application Intensive digestion for new builds and sludge centres Partial intensification / class B sludge.](https://reader035.fdocuments.net/reader035/viewer/2022081516/56649cf75503460f949c6f48/html5/thumbnails/9.jpg)
SolidStream® Standardised Design
60 tds/day - 3 x SolidStream®
System is easily configured with 1, 2 or 3 lines.
All units are standardized for reducing risk in projects.
System based on module design.