DOMESTIC ELECTRICAL INSTALLATION CONDITION REPORT
This certificate is not valid if the serialnumber has been defaced or altered DPN5/0307601
Ori
gin
al
(To
the
pers
on o
rder
ing
the
wor
k)
Issued in accordance with British Standard 7671 – Requirements for Electrical Installations by an Approved Contractor or Conforming Body enrolled with NICEIC, Warwick House, Houghton Hall Park, Houghton Regis, Dunstable LU5 5ZX.
A. DETAILS OF THE CLIENT
Client:
Address:
Hammond Mr C
21 Geln Iris AvenueCanterburyCanterburyKent
Postcode: CT2 8HP
B. PURPOSE OF THE REPORT
Purposefor whichthisreport isrequired:
5 year Condition Report for letting
Date(s) on which inspection and testing were carried out:
12/11/2012
C. DETAILS OF THE INSTALLATION
Occupier Students
Address 21 Glen Iris AvenueCanterburyKent
Postcode: CT2 8HP
Estimated age of theelectrical installation: 20+ years Evidence of alterations
or additionsá If yes,
estimatedage
5 years
Date of previousinspection:
09/11/2007 Electrical Installation Certificate No or previousPeriodic Inspection or Condition Report No:
DPR1/0164819
Records of installation available: áRecords held by: Landlord
D. EXTENT OF THE INSTALLATION AND LIMITATIONS OF THE INSPECTION AND TESTING
Extent of the electrical installation covered by this report:
Fixed power & lighting.
Agreed limitations (including the reasons), if any, on the inspection and testing:
Concealed wiring, portable appliances, central heating & boiler not tested.
Agreed with: N/A
Operational limitations including the reasons (see page No. N/A )N/A
The inspection has been carried out in accordance with BS 7671, as amended. Cables concealed within trunking and conduits, or cables and conduits concealed under floors, in inaccessible roof spaces and generally within the fabric of the building or underground, have not been visually inspected.
E. SUMMARY OF THE CONDITION OF THE INSTALLATION
General condition of the installation (in terms of electrical safety):
With the exception of items listed above, the installation is in fair condition for age and use.
The presence of green grunge is the PVC cable breaking down to its natural state which is oil; this is not detrimental to the electrical
installation at present but does require closely monitoring on an annual basis and therefore we have only given a one year certificate.
The electrical installation will require a complete rewire in the not too distant future.
Summary of the condition of the installation continued on additional pages? No Yes Specify pageá
Overall assessmentof the installation:
SATISFACTORY / UNSATISFACTORY (Delete as appropriate)
An ‘Unsatisfactory’ assessment indicates that dangerous and/or potentially dangerous conditions have been identified
This report should have been reviewed and confirmed by the registered Qualified Supervisor of the Approved Contractor responsible for issuing it. (See declaration on page 2)
This report is based on the model forms shown in Appendix 6 of BS 7671 Published by NICEIC, a part of the Ascertiva Group Copyright The Electrical Safety Council (July 2011)
Page 1 of 7Please see the 'Notes for Recipients'on the reverse of this page
DOMESTIC ELECTRICAL INSTALLATION CONDITION REPORT
This certificate is not valid if the serialnumber has been defaced or altered DPN5/0307601
Page 2 of 7
DOMESTIC ELECTRICAL INSTALLATION CONDITION REPORT
This certificate is not valid if the serialnumber has been defaced or altered DPN5/0307601
Ori
gin
al
(To
the
pers
on o
rder
ing
the
wor
k)
Please see the 'Guidance for Recipients on the Recommendation Codes'
This report is based on the model forms shown in Appendix 6 of BS 7671 Published by NICEIC, a part of the Ascertiva Group Copyright The Electrical Safety Council (July 2011)
F. OBSERVATIONS AND RECOMMENDATIONS FOR ACTIONS TO BE TAKEN
Referring to the attached schedules of inspection and test results, an subject to the limitations at D:
Item No ObservationsClassification
code ÚFurther investigationrequired ( Y or á)
There are no items adversely affecting electrical safety. N/A or The following observations and recommendations forare made
á
Additional Pages? No Yesá Specify page
ÚOne of the following codes, as appropriate, has been allocated to each of theobservations made above to indicate to the person(s) responsible for the installationthe degree of urgency for remedial action:
Code C1 "Danger Present". Risk of injury. Immediate remedial action required.
Code C2 "Potentially dangerous". Urgent remedial action required.
Code C3 "Improvement recommended".
Please see the reverse of this page for guidance regarding the Classification codes.
Immediate remedial actionrequired for items: N/A
Urgent remedial actionrequired for items: N/A
Further investigationrequired for items: N/A
Improvementrecommended for items: 1, 2, 3, 4, 5
1 Green grunge found in sockets in kitchen (PVC insulation breaking down) C3
2 Switch lines not identified as line conductors at terminations (for example, a conductor having
blue insulation is not sleeved brown in switches or lighting points)C3
3 Absence of RCD protection for socket-outlets in a location containing a bath or shower, other than
for SELV or shaver socket-outletsC3
4 Absence of RCD protection for cables installed at a depth of less than 50 mm from a surface of a
wall or partition where the cables do not incorporate an earthed metallic covering, are not
enclosed in earthed metalwork, or are not mechanically protected against penetration by nails and
the like
C3
5 Cable colours do not conform to BS7671:2008 (2011 as amended) C3
G. DECLARATIONI/We, being the person(s) responsible for the inspection and testing of theelectrical installation (as indicated by my/our signatures below), particulars ofwhich are described on page 1 (see C), having exercised reasonable skill andcare when carrying out the inspection and testing, hereby declare that theinformation in this report, including the observations (see F) and the attachedschedules (see H), provides an accurate assessment of the condition of theelectrical installation taking into account the stated extent of the installationand the limitations on the inspection and testing (see D).
I/We further declare that in my/our judgement, the saidinstallation was overall in
SATISFACTORY / UNSATISFACTORY*
condition (see F) at the time the inspection was carried out, and that itshould be further inspected as recommended (see I).
*Delete as appropriate
INSPECTION, TESTING AND ASSESSMENT BY:
Signature
Name(CAPITALS) MARK HERBERT
Position Inspector
Date: 12/11/2012
REPORT REVIEWED AND CONFIRMED BY:
Signature
Name(CAPITALS) PAUL UNDERDOWN
(Registered Qualified Supervisor for the Approved Contractor at J)
Date: 12/11/2012
H. SCHEDULES AND ADDITIONAL PAGES
Schedule of Inspection: Page(s) No 4,5,6
Additional pages, including data sheets foradditional source(s) : Page No(s)
Schedule of Test Results for the Installation: Page No(s) 7
Schedule of Circuit Details for the Installation: Page No(s) 7
The pages identified are an essential part of this report. The report is valid only ifaccompanied by all the schedules and additional pages identified above.
DOMESTIC ELECTRICAL INSTALLATION CONDITION REPORT
This certificate is not valid if the serialnumber has been defaced or altered DPN5/0307601
Page 3 of 7
Ori
gin
al
(To
the
pers
on o
rder
ing
the
wor
k)
I. NEXT INSPECTION
I/We recommend that this installation is further inspected and tested after an interval of not more than
1 year/occupation change
(Enter interval in terms of years, months or weeks, as appropriate))
provided that any items at F which have been attributed a Classificationcode C1 (danger present) are remedied immediately and that any itemswhich have been attributed a code C2 (potentially dangerous) or requirefurther investigation are remedied or investigated respectively as a matterof urgency. Items which have been attributed a Classification code C3should be improved as soon as practicable (see F)
J. DETAILS OF NICEIC APPROVED CONTRACTOR
Trading Title: Belmont Group, The
Address: Wavecrest HouseWestern EsplanadeHerne BayKent
Postcode: CT6 8JA
Telephone number: 01227 808 644
Email Address: [email protected]
Enrolement number:(Essential information)
D0171480000
Branch number:(if applicable) N/A
K. SUPPLY CHARACTERISTICS AND EARTHING ARRANGEMENTS
System Type(s) Number and Type of Live Conductors Nature of Supply ParametersCharacteristics of Primary SupplyOvercurrent Protective Device(s)
TN-S á
TN-C-S N/A
TT N/A
1-phase(2 wire) á2-phase(3 wire) N/A
3-phase(3 wire) N/A
1-phase(3 wire) N/A
3-phase(4 wire) N/A
a.c. N/AOther (please state)
N/A
NominalVoltage(s): Uþ N/A V 230UÒþ V
Numberof sources 1
Nominalfrequency, fþ 50 Hz
Prospective faultcurrent, IÙÄÅ 1.29 kA
External earth faultloop impendance, Ñ ÄÅ 0.28 É
Notes:(1) by enquiry(2) by enquiry or by measurement(3)where more than one source, recordthe higher or highest value(4) by measurement
BS(EN) BS 88 Fuse HRC gG(General)
Type gG
Rated current 80 A
33 kAShort-circuitcapacity
Confirmation ofsupply polarity á (á)
L. PARTICULARS OF INSTALLATION AT THE ORIGIN
Means of Earthing Details of Installation Earth Electrode (where applicable)
Main Switch or Circuit-Breaker
Distributor'sfacility: á
Installationearth electrode: N/A
Type:(eg rod(s),tape etc) N/A
Electroderesistance, RÕ: N/A (É)
Location: N/A
Method ofmeasurement: N/A
* (applicable only where an RCD is suitable and is used as a main circuit-breaker)
BS EN 60947-Type:BS(EN)
2No ofPoles
CopperPrimary supplyconductorsmaterial
25Primary supplyconductorscsa
mmâ
Voltagerating 250
Ratedcurrent,IÐ 100
RCD operatingcurrent, IÜ * N/A
Rated timedelay N/A
RCD operatingtime (atIÜ )* N/A
V
A
mA
ms
ms
Earthing and protective bonding conductorsEarthing conductor
Conductormaterial Copper
Conductorcsa 16
mmâConnection/ ácontinuityverified
(á)
Main protective bonding conductors
Conductormaterial Copper
Conductorcsa 10 mmâ
Connection/ ácontinuityverified
(á)
Bonding of extraneous-conductive-parts (á)
Waterservice á
Oilservice N/A
Lightningprotection N/A
GasService á
Structuralsteel N/A
Other incomingservice(s) N/A
N/ASpecify
This report is based on the model forms shown in Appendix 6 of BS 7671. Published by NICEIC, a part of the Ascertiva Group Copyright The Electrical Safety Council (July 2011)
* All Boxes must be completed
'á' indicates Acceptable condition
'LIM' indicates a limitation
'N/A' indicates Not applicable
Unacceptable condition state C1 or C2
Improvement recommended state C3
Further investigation required state F/I (to determine whether danger or potential(danger exists)
OutcomeProvide additional comment where appropriate onattached numbered sheets. C1, C2 and C3 coded itemsto be recorded in section F of the report.
This report is based on the model forms shown in Appendix 6 of BS 7671. Published by NICEIC, a part of the Ascertiva Group Copyright The Electrical Safety Council (July 2011)
Page 4 of 7
DOMESTIC ELECTRICAL INSTALLATION CONDITION REPORT
This certificate is not valid if the serialnumber has been defaced or altered DPN5/0307601
Ori
gin
al
(To
the
pers
on o
rder
ing
the
wor
k)
SCHEDULE OF INSPECTIONS Ú
Item Description Outcome * Location reference Item Description Outcome * Location reference
1.0 Condition/adequacy of distributor’s/supply intake equipment
1.1 Service cable á
1.2 Service cut-out/fuse(s) á
1.3 Meter tails - distributor á
1.4 Meter tails - consumer á
1.5 Metering equipment á
1.6 Means of main isolation (where present) á
2.0 Presence of adequate arrangementsfor other sources(microgenerators etc)
N/A
3.0 Earthing and bonding arrangements
3.1 Presence and condition of distributor’searthing arrangement á
3.2 Presence and condition of earth electrode connection
N/A
3.3 Confirmation of adequateearthing conductor size
á
3.4 Accessibility and condition of earthingconductor at Main Earthing Terminal (MET)
á
3.5 Confirmation of adequate main protectivebonding conductor sizes
á
3.6 Condition and accessibility of mainprotective bonding conductorconnections
á
3.7 Provision of earthing and bondinglabels at all appropriate locations
á
4.0 Consumer unit(s)
4.1 Adequacy of working spaceor access to consumer unit á
4.2 Security of fixing á
4.3 Condition of enclosure(s) in terms ofIP rating
á
4.4 Condition of enclosure(s) in terms offire rating
á
4.5 Enclosure not damaged/deteriorated soas to impair safety
á
4.6 Presence of linked main switch á
4.7 Operation of main switch(functional check)
á
4.8 Manual operation of circuit-breakersand RCDs to prove disconnection
á
4.9 Correct identification of circuitsand protective devices
á
4.10 Presence of RCD test notice ator near consumer unit
á
4.11 Presence of non-standard (mixed)cable colour warning notice at or nearconsumer unit
N/A
4.12 Presence of alternative supply warningnotice at or near consumer unit
N/A
4.13 Presence of replacement next inspectionrecommendation label
á
4.14 Presence of other required labelling(please specify)
N/A
4.15 Examination of protective device(s) andbase(s); correct type and rating(no signs of unacceptable thermaldamage, arcing or overheating)
á
4.16 Single-pole protective devices in theline conductor only
á
* All Boxes must be completed
'á' indicates Acceptable condition
'LIM' indicates alimitation
'N/A' indicates Not applicable
Unacceptable condition state C1 or C2
Improvement recommended state C3
Further investigation required state F/I (to determine whether danger or potential(danger exists)
OutcomeProvide additional comment where appropriate onattached numbered sheets. C1, C2 and C3 coded itemsto be recorded in section F of the report.
This report is based on the model forms shown in Appendix 6 of BS 7671. Published by NICEIC, a part of the Ascertiva Group Copyright The Electrical Safety Council (July 2011)
Page 5 of 7
DOMESTIC ELECTRICAL INSTALLATION CONDITION REPORT
This certificate is not valid if the serialnumber has been defaced or altered DPN5/0307601
Ori
gin
al
(To
the
pers
on o
rder
ing
the
wor
k)
SCHEDULE OF INSPECTIONS Ú
Item Description Outcome * Location reference Item Description Outcome * Location reference
4.17 Protection against mechanical damagewhere cables enter metallic consumerunit
N/A
4.18 Protection against electromagneticeffects where cables enter metallicconsumer unit/enclosure
á
4.19 RCDs provided for fault protection– includes RCBOs
á
4.20 RCDs provided for additional protection– includes RCBOs
C3 No RCD protection for lighting circuits 1,2, & 3
5.0 Final circuits
5.1 Identification of conductors C3 Absence of switch line identification
5.2 Cables correctly supportedthroughout their run
á
5.3 Condition of insulation of live parts á
5.4 Non-sheathed cables protected byenclosure in conduit, ducting ortrunking (including confirmation of theintegrity of conduit and trunking systems)
á
5.5 Adequacy of cables for current-carryingcapacity with regard to the typeand nature of installation
á
5.6 Adequacy of protective devices; typeand rated current for fault protection
C3 No RCD protection for lighting circuits 1,2, & 3
5.7 Presence and adequacy of circuitprotective conductors
á
5.8 Co-ordination between conductors andoverload protective devices
á
5.9 Wiring system(s) appropriate for thetype and nature of the installationand external influences
C3 Wiring showing green grunge
5.10 Concealed cables installed in prescribedzones (see extent and limitations)
á
5.11 Concealed cables incorporating earthedarmour or sheath, or run within earthedwiring containment system, or otherwiseprotected against mechanical damagefrom nails, screws and the like wherenot in prescribed zones or not protectedby 30 mA RCD (see extent and limitations)
á
5.12 Provision of additional protection byRCD not exceeding 30 mA
á
* used to supply mobile equipment notexceeding 32 A ratingfor use outdoors
á
* for all socket-outlets not exceeding20 A rating unless exempt
á
* for cables concealed in walls orpartitions
C3 No RCD protection for lighting circuits 1,2, & 3
5.13 Provision of fire barriers, sealingarrangements and protectionagainst thermal effects
á
5.14 Band II cables segregated/separatedfrom Band I cables
N/A
5.15 Cables segregated/separated fromcommunications cabling
N/A
5.16 Cables segregated/separated fromnon-electrical services
N/A
5.17 Termination of cables at enclosures(extent of sampling indicatedin Section D of the report )
á
* Connections soundly made andunder no undue strain
á
* No basic insulation of a conductorvisible outside enclosures
á
* Connections of live conductorsadequately enclosed
á
* Adequately connected at point ofentry to enclosure (glands,bushes etc.)
á
* All Boxes must be completed
'á' indicates Acceptable condition
'LIM' indicates alimitation
'N/A' indicates Not applicable
Unacceptable condition state C1 or C2
Improvement recommended state C3
Further investigation required state F/I (to determine whether danger or potential(danger exists)
OutcomeProvide additional comment where appropriate onattached numbered sheets. C1, C2 and C3 coded itemsto be recorded in section F of the report.
This report is based on the model forms shown in Appendix 6 of BS 7671. Published by NICEIC, a part of the Ascertiva Group Copyright The Electrical Safety Council (July 2011)
Page 6 of 7
DOMESTIC ELECTRICAL INSTALLATION CONDITION REPORT
This certificate is not valid if the serialnumber has been defaced or altered DPN5/0307601
Ori
gin
al
(To
the
pers
on o
rder
ing
the
wor
k)
SCHEDULE OF INSPECTIONS Ú
Item Description Outcome * Location reference Item Description Outcome * Location reference
5.18 Condition of accessories includingsocket-outlets, switches andjoint boxes
á
5.19 Suitability of accessories for externalinfluences
á
6.0 Isolation and switching (isolation, switching off for mechanical maintenance,emergency switching/stopping and functional switching)
6.1 In General
* presence and condition ofappropriate devices á
* correct operation verified á
6.2 For isolation and switching formechanical maintenance only
* capable of being secured in the OFFposition where appropriate á
* acceptable location – state if localor remote from equipment beingcontrolled where appropriate
á
* clearly identified by positionand/or durable marking(s)
á
6.3 For isolation only
* warning label(s) posted in situationswhere live parts cannot be isolatedby the operation of a single device
á
6.4 For emergency switching/stopping only
* readily accessible for operationwhere danger might occur á
7.0 Current-using equipment(Permanently connected)
7.1 Condition of equipment in terms ofIP rating á
7.2 Equipment does not constitutea fire hazard
á
7.3 Enclosure not damaged/deterioratedso as to impair safety
á
7.4 Suitability for the environment andexternal influences
á
7.5 Security of fixing á
7.6 Cable entry holes in ceiling aboveluminaires, sized or sealed so as torestrict the spread of fireList number and location of luminairesinspected. (Separate page)
á
7.7 Recessed luminaires (downlighters)
* correct type of lamps fitted N/A
* installed to minimise build-up of heatby use of ‘fire rated’ fittings,insulation displacement box or similar
N/A
* no signs of overheating tosurrounding building fabric
N/A
* no signs of overheating toconductors/terminations
N/A
8.0 Location(s) containing a bath or shower
8.1 Additional protection for all lowvoltage (LV) circuits by RCDnot exceeding 30 mA
C3 No RCD for bathroom lighting circuit 2
8.2 Where used as a protective measure,requirements for SELV orPELV are met
á
8.3 Shaver sockets comply withBS EN 61558-2-5 or BS 3535
á
8.4 Presence of supplementary bondingconductors unless not requiredby BS 7671: 2008
á
8.5 Low voltage (e.g. 230 volts) socketoutlets sited at least 3 m from zone 1
N/A
8.6 Suitability of equipment for externalinfluences for installed locationin terms of IP rating
á
8.7 Suitability of equipment for installationin a particular zone
á
8.8 Suitability of current-using equipmentfor a particular position withinthe location
á
9.0 Other special installations or locations - Part 7s
9.1 List all other special installations orlocations present, if any. Record theresults of particular inspection appliedseparately
á
Page 7 of 7
SCHEDULES
This certificate is not valid if the serialnumber has been defaced or altered DPN5/0307601
CODE
S FO
R TY
PE O
F W
IRIN
GA
BC
DE
FG
H
Ther
mop
last
icin
sula
ted/
shea
thed
cab
les
Ther
mop
last
icca
bles
inm
etal
lic c
ondu
it
Ther
mop
last
icca
bles
in n
onm
etal
lic c
ondu
it
Ther
mop
last
icca
bles
inm
etal
lic tr
unki
ng
Ther
mop
last
icca
bles
in n
onm
etal
lic tr
unki
ng
Ther
mop
last
ic/
SWA
cabl
esTh
erm
oset
ting/
cabl
esM
iner
al-
insu
late
dca
bles
O (O
ther
- pl
ease
sta
te)
N/A
X
Location of consumer unit(s) Designation of consumer unit(s) Prospective fault currentat consumer unit(s) kA
TEST INSTRUMENTS
Multi-functional
Insulationresistance Continuity Earth electrode
resistanceEarth fault currentimpedance RCD
Garage DB1 (Tenby) 1.29
10250407 N/A N/A N/A N/A 10250407
This report is based on the model forms shown in Appendix 6 of BS 7671. Published by NICEIC, a part of the Ascertiva Group Copyright The Electrical Safety Council (July 2011)
Page 7 of 7
Ori
gin
al
(To
the
pers
on o
rder
ing
the
wor
k)
CIRCUIT DETAILS
Cir
cuit
num
ber
and
phas
e
Circuit designation
* To be completed only where this consumer unitis remote from the origin of the installation.
Record details of the circuit supplying this consumerunit in the bold box T
ype
of w
irin
g(s
ee c
ode
belo
w)
Ref
eren
ce M
etho
d(s
ee A
ppen
dix
4of
BS
767
1)
Num
ber
ofpo
ints
ser
ved Live
(mmâ)
Circuitconductors: csa
cpc
(mmâ)
Max
. dis
conn
ecti
onti
me
perm
itte
dby
BS
767
1
(s)
BS (EN)
Typ
e N
o
Rat
ing
(A)
Overcurrent protective devices
Sho
rt-c
ircu
itca
paci
ty
(kA)
RCD
Ope
rati
ngcu
rren
t, IÜ
(mA)
Max
imum
Öpe
rmit
ted
by B
S 7
671
(É)
N/A Main Switch N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
1 Lighting downstairs F A 9 1.0 1.0 0.4 60898 MCB B 6 6 N/A 7.67
2 Lighting upstairs F A 6 1.0 1.0 0.4 60898 MCB B 6 6 N/A 7.67
3 Lighting garage F A 1 1.0 1.0 0.4 60898 MCB B 6 6 N/A 7.67
4 Spare N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
5 Spare N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
N/A RCD N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
N/A RCD N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
6 Cooker F A 1 6.0 4.0 0.4 60898 MCB B 32 6 30 1.44
7 Sockets - ring F A 16 2.5 1.5 0.4 60898 MCB B 32 6 30 1.44
8 Socket - garage F A 1 2.5 1.5 0.4 60898 MCB B 16 6 30 2.88
9 Heating F A 1 2.5 1.5 0.4 60898 MCB B 16 6 30 2.88
10 Immersion F A 1 2.5 1.5 0.4 60898 MCB B 16 6 30 2.88
TEST RESULTS
rã(Line)
rÐ(Neutral)
Ring final circuits only(measured end to end)
rå(cpc) Rã+Rå
Circuit impedances(É)
All circuits(At least one column
to be completed)
Rå
Line
/Lin
e
(MÉ)
Line
/Neu
tral
(MÉ)
Line
/Ear
th
(MÉ)
Insulation resistance
Neut
ral/E
arth
(MÉ)
Pola
rity
(á)
Maximummeasured earth
fault loopimpedance, Ö
* See note below
(É)
at IÜ
(ms)
RCD operatingtimes
at 5IÜ
(if applicable)
(ms)
Testbutton
operation
(á)
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
N/A N/A N/A 0.50 N/A N/A >999 >999 >999 á 1.10 N/A N/A
N/A N/A N/A 0.38 N/A N/A >999 >999 >999 á 0.84 N/A N/A
N/A N/A N/A 0.17 N/A N/A >999 >999 >999 á 0.48 N/A N/A
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A á
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A á
N/A N/A N/A 0.11 N/A N/A >999 >999 <999 á 0.51 20.8 19.3
0.51 0.51 0.88 0.32 N/A N/A >999 >999 <999 á 0.60 20.8 19.3
N/A N/A N/A 0.09 N/A N/A >999 >999 <999 á 0.49 20.8 19.3
N/A N/A N/A 0.33 N/A N/A >999 >999 <999 á 0.56 20.8 19.3
N/A N/A N/A 0.06 N/A N/A >999 >999 <999 á 0.45 20.8 19.3