Thermography image comparison - testo 875 vs. competitors
-
Upload
testo-limited -
Category
Technology
-
view
302 -
download
2
description
Transcript of Thermography image comparison - testo 875 vs. competitors
![Page 1: Thermography image comparison - testo 875 vs. competitors](https://reader030.fdocuments.net/reader030/viewer/2022020207/555bd331d8b42ae4478b514a/html5/thumbnails/1.jpg)
FOV-comparison
testo 875 vs. - Fluke Ti25
- Flir i7
- Irisys 4010
![Page 2: Thermography image comparison - testo 875 vs. competitors](https://reader030.fdocuments.net/reader030/viewer/2022020207/555bd331d8b42ae4478b514a/html5/thumbnails/2.jpg)
2/13 Testo AG, Image comparison testo 875, 1000len-mkh, 01.07.2013, Confidentiality 1
Image comparison
Product testo 875 Fluke TI25 Flir I7 Irisys 4010
Detector 160 x 120 160 x 120 140 x 140 160 x 120
FOV 32° x 23° 23° x 17° 25° x 25° 20º x 15º
This image comparison shows how the diffrent FOVs influence the image frame of the
individuall camera:
In the first comparison all thermal imagers measure an object from the same distance. So you
can see the different image sections you get with several FOV’s of the thermal imagers.
In the second comparison we tried to get the same image section for every thermal imager
with the different FOV’s. So the objects had to be measured from different distances,
depending on the camera. You will see these different distances in the presentation.
![Page 3: Thermography image comparison - testo 875 vs. competitors](https://reader030.fdocuments.net/reader030/viewer/2022020207/555bd331d8b42ae4478b514a/html5/thumbnails/3.jpg)
FOV-comparison
1. Comparison
Same distance/ different image section
![Page 4: Thermography image comparison - testo 875 vs. competitors](https://reader030.fdocuments.net/reader030/viewer/2022020207/555bd331d8b42ae4478b514a/html5/thumbnails/4.jpg)
4/13 Testo AG, Image comparison testo 875, 1000len-mkh, 01.07.2013, Confidentiality 1
Switch cabinet - distance 35.4" (90cm)
Irisys 4010
Testo 875 Fluke Ti25
Flir i7
![Page 5: Thermography image comparison - testo 875 vs. competitors](https://reader030.fdocuments.net/reader030/viewer/2022020207/555bd331d8b42ae4478b514a/html5/thumbnails/5.jpg)
5/13 Testo AG, Image comparison testo 875, 1000len-mkh, 01.07.2013, Confidentiality 1
Switch cabinet - distance 23.6" (60cm)
Irisys 4010
Testo 875 Fluke Ti25
Flir i7
![Page 6: Thermography image comparison - testo 875 vs. competitors](https://reader030.fdocuments.net/reader030/viewer/2022020207/555bd331d8b42ae4478b514a/html5/thumbnails/6.jpg)
6/13 Testo AG, Image comparison testo 875, 1000len-mkh, 01.07.2013, Confidentiality 1
Motor - distance 31.5" (80cm)
Irisys 4010
Testo 875 Fluke Ti25
Flir i7
![Page 7: Thermography image comparison - testo 875 vs. competitors](https://reader030.fdocuments.net/reader030/viewer/2022020207/555bd331d8b42ae4478b514a/html5/thumbnails/7.jpg)
7/13 Testo AG, Image comparison testo 875, 1000len-mkh, 01.07.2013, Confidentiality 1
Air heating system – distance 9.8 ft (3m)
Testo 875 Fluke Ti25
Flir i7
![Page 8: Thermography image comparison - testo 875 vs. competitors](https://reader030.fdocuments.net/reader030/viewer/2022020207/555bd331d8b42ae4478b514a/html5/thumbnails/8.jpg)
8/13 Testo AG, Image comparison testo 875, 1000len-mkh, 01.07.2013, Confidentiality 1
Heating loops – distance 9.8 ft (3m)
Irisys 4010
Testo 875 Fluke Ti25
![Page 9: Thermography image comparison - testo 875 vs. competitors](https://reader030.fdocuments.net/reader030/viewer/2022020207/555bd331d8b42ae4478b514a/html5/thumbnails/9.jpg)
FOV-comparison
2. Comparison
Same image section/ different distance
10.06.2013 Autor
![Page 10: Thermography image comparison - testo 875 vs. competitors](https://reader030.fdocuments.net/reader030/viewer/2022020207/555bd331d8b42ae4478b514a/html5/thumbnails/10.jpg)
10/13 Testo AG, Image comparison testo 875, 1000len-mkh, 01.07.2013, Confidentiality 1
Same field of view: Switch cabinet
Flir i7 - Distance: 105 cm / 41.3“ Irisys 4010 - Distance: 105 cm / 41.3“
Testo 875 - Distance: 90 cm / 35.4“ Fluke Ti25 - Distance: 120 cm / 47.2“
![Page 11: Thermography image comparison - testo 875 vs. competitors](https://reader030.fdocuments.net/reader030/viewer/2022020207/555bd331d8b42ae4478b514a/html5/thumbnails/11.jpg)
11/13 Testo AG, Image comparison testo 875, 1000len-mkh, 01.07.2013, Confidentiality 1
Same field of view: Switch cabinet
Testo 875 - Distance: 60 cm / 23.6“ Fluke Ti25 - Distance: 80 cm / 31.5“
Irisys 4010 - Distance: 100 cm / 39.4“ Flir i7 - Distance: 60 cm / 23.6“
![Page 12: Thermography image comparison - testo 875 vs. competitors](https://reader030.fdocuments.net/reader030/viewer/2022020207/555bd331d8b42ae4478b514a/html5/thumbnails/12.jpg)
12/13 Testo AG, Image comparison testo 875, 1000len-mkh, 01.07.2013, Confidentiality 1
Same field of view: Motor
Testo 875 - Distance: 80 cm / 31.5“ Fluke Ti25 - Distance: 115 cm / 45.3“
Irisys 4010 - Distance: 130 cm / 51.2“ Flir i7 - Distance: 80 cm / 31.5“
![Page 13: Thermography image comparison - testo 875 vs. competitors](https://reader030.fdocuments.net/reader030/viewer/2022020207/555bd331d8b42ae4478b514a/html5/thumbnails/13.jpg)
13/13 Testo AG, Image comparison testo 875, 1000len-mkh, 01.07.2013, Confidentiality 1
Same field of view: Air heating system
Testo 875 - Distance: 3 m / 118.1“ Fluke Ti25 - Distance: 4,1 m / 161.4“
Irisys 4010 - Distance: 5 m / 196.9“ Flir i7 - Distance: 3 m / 118.1“