Thermo Scientific Shandon Pathology Workstations and Workbenches •  Downdraft or back draft fume removal •  Stainless-steel construction •  Elevating or fixed-height work stations •  Hands-free controls • Three efficient ventilation system options

Transcript of Thermo Scientific Shandon Pathology Workstations and ... · 4 Thermo Scientific Shandon Gross-Star...

Page 1: Thermo Scientific Shandon Pathology Workstations and ... · 4 Thermo Scientific Shandon Gross-Star Pathology Workbench Superior Functionality • Downdraft and/or back draft ventilation

1

Thermo Scientific Shandon Pathology Workstations and Workbenches

•  Downdraft or back draft fume removal

•  Stainless-steel construction

•  Elevating or fixed-height work stations

•  Hands-free controls

• Three efficient ventilation system options

Page 2: Thermo Scientific Shandon Pathology Workstations and ... · 4 Thermo Scientific Shandon Gross-Star Pathology Workbench Superior Functionality • Downdraft and/or back draft ventilation

2

Superior Functionality• Downdraft and/or back draft ventilation•  Units with elevating or fixed-height work surface are available•    Elevating units have user-adjustable work surface height of 

33 to 41" (83.8 to 104.1cm)•  Fixed-height units have a work surface height that is factory 

set to your specification•  Deep sink with cold/hot water faucet (removable for easy 

cleaning)•  Optional ½ hp disposal is available (please check with local 

authorities before ordering a unit with a disposal; some areas prohibit the use of disposals)

•  Hands-free foot pedal controls for cold/hot water faucet and optional formalin dispensing system

• Abundant light is directed to the work surface• Vacuum breaker-protected water supply• Appliances plug directly into the unit for convenient use• Ventilated base cabinet• Fume removal is efficient and quiet•  Optional camera and monitor/keyboard brackets are available• Camera bracket slides along the width of the unit•  Monitor bracket is designed to hold a thin flat-screen display 

monitor•  Each unit comes with an integral centimeter ruler on the 

front lip of the tabletop, magnetic instrument bar, integral glove dispenser, and paper towel dispenser   

•  Built-in manifold rinse washes down wetted internal surfaces quickly

•  Perforated grid plates for work surface (removable for easy cleaning)

Superior Quality•  Standard Type 304 or optional Type 316 stainless-steel 

construction•  Rugged design provides stability and is built tough to  

withstand years of extensive work without corrosion•  Perforated grid plates are standard Type 316 stainless-steel 

construction

Designed for Easy Shipping and Installation•   All Gross-Star™ workstations ship in two convenient assemblies

t  hat fit through a standard 32" (81.3cm) doorway•  The two assemblies link firmly with easy-to-assemble plates 

and fasteners•  Units connect to facility cold/hot water supplies and drains•  Units are hard wired to facility electrical system

Installed Depth from Back of Unit to Wall•  For the purpose of room planning, backs of fixed-height units 

can be flush to walls•  Elevating units require approximately 1" (2.54cm) clearance 

between the back of the unit and wall to accommodate height adjustment

Three Ventilation System Options•  Recirculating exhaust models feature formaldehyde neutralizing 

filters and an integral blower•  External exhaust models include an integral blower for  

short distances•  Remote exhaust models connect to the facility exhaust system

Physical Specifications•  Overall Dimensions (H x W x D): 84 to 92 x 60 x 30" 

(213.4 to 233.7 x 152.4 x 76.2cm)•  Work surface height within range of 33 to 41" (83.8 to 

104.1 cm); 36" (91.4cm) on fixed-height units unless  customer-specified otherwise with order

• Sink (W x L x D): 14 x 16 x 7.5" (35.6 x 40.6 x 19.1cm)•  Top Piece Weight: Uncrated, 275 lb. (124.7kg); crated,  

375 lb. (170.1kg)•  Bottom Piece Weight: Uncrated, 400 lb. (181.4kg); crated,  

500 lb.(226.8kg)

Electrical Specifications•  110 –120V, 60Hz, 1Ph•  Draw 20 amps and require a separate 15-amp circuit for one 

hospital-grade duplex ground fault current interrupter (GFCI) receptacle

Plumbing Specifications•  ¾" (1.9cm) hot and cold water supply lines with shutoff 

valves and 1½" (3.8cm) drain line must be supplied•  ½" (1.3cm) industrial-grade flexible hoses with ¾" (1.9cm) 

female hose fittings are supplied for connection to water supply lines

•  1½" (3.8cm) I.D. reinforced flexible hose is provided for  connection to facility drain line

CertificationsUL/cUL (for 110-120V units only)

Hands-free foot pedal controls for standard cold/hot water faucet and optional formalin dispensing system.

Thermo Scientific Shandon Gross-Star Pathology Workstation

Vented Trash can.

Page 3: Thermo Scientific Shandon Pathology Workstations and ... · 4 Thermo Scientific Shandon Gross-Star Pathology Workbench Superior Functionality • Downdraft and/or back draft ventilation

3

On the Top: Optional camera bracket and standard instrument bar.

On the Bottom: Optional monitor/keyboard brackets.

Included With Product

Description Order Number

Work surface height within range of 33  to 41" (83.8 to 104.1 cm); 36" (91.4cm)  on fixed-height units unless customer- specified otherwise with order

Downdraft ventilation —

Ventilated base cabinet —

Removable sink —

Cold/hot water faucet with foot pedal controls —

Manifold rinse with manual control —

Hand spray —

Duplex GFCI Electrical Receptacle —

Centimeter ruler on front lip of tabletop —

Adjustable lower shelf (W x D):  16 x 8" (40.6 x 20.3cm) —

Fixed upper shelf —

Fluorescent light —

Type 304 stainless-steel construction —

Integrated glove dispenser —

Waste formalin collection system with high-level alarm —

Magnetic instrument bar (instruments not included) P104393

Towel dispenser for C-fold towels 1070214

C-fold towels 104401 

Ordering Information

Description Order Number

Elevating 110-120V, 60Hz, 1Ph models with right-hand sink  and foot pedal controls

Recirculating exhaust via filters and integral blower

B21100

External exhaust via integral blower  and facility duct (20' max.; not included)

B21101

Remote exhaust via facility duct and blower (not included)

B21102

Fixed-height 110-120V, 60Hz, 1Ph models with right-hand sink and foot pedal controls

Recirculating exhaust via filters and integral blower

B21103

External exhaust via integral blower  and facility duct (20' max.; not included)

B21104

Remote exhaust via facility duct and blower (not included)

B21105

Elevating and fixed-height units with left-hand sinks, manual controls and/or 220-240V, 50/60Hz, 1Ph electrical ratings are available upon request.

Factory Installed Options•  Waste formalin collection systems with alarms feature both 

audible and visual alarms

Description Order Number

Disposal, ½ hp with rocker switch B21111

Back draft and downdraft fume  capture system B21216

Back draft fume capture system  (no downdraft) B21114

Fresh formalin dispensing system with foot pedal control and low-level alarm B21116

Hood assembly B21113

Task lamp (specify left or right side) B1001405

Type 316 stainless-steel construction Special Order

Accessories

Description Order Number

Adjustable shelf (W x D):  16 x 8" (40.6 x 20.3cm) B21203

Camera bracket B21125

Camera bracket adapter  (for use with hood assembly only) B21126

Fresh formalin dispensing carboy 104395

Magnifier for B1001405 task lamp B1001326

Movable dictation recorder rack 10629

Movable requisition rack 105417

Photographic blue polyethylene  dissecting board B36115

Shelf for Thermo Scientific Shandon  MicroWriter™ Cassette labeler B21215

Splash shield on flexible arm  (requires drilling for installation) B21201

Thin monitor/keyboard bracket B21110

Ventilated trash bin  (specify left or right side) B21115

Gross-Star Pathology Workstation exhaust information continued to page 5.

Page 4: Thermo Scientific Shandon Pathology Workstations and ... · 4 Thermo Scientific Shandon Gross-Star Pathology Workbench Superior Functionality • Downdraft and/or back draft ventilation

4

Thermo Scientific Shandon Gross-Star Pathology Workbench

Superior Functionality • Downdraft and/or back draft ventilation•  Units with elevating or fixed-height work surface 

are available•  Elevating units have user-adjustable work surface 

height of 33 to 41" (83.8 to 104.1cm)•  Fixed-height units have a work surface height that is  

factory set to your specification•  Deep sink with cold/hot water faucet (removable for 

easy cleaning)•  Optional ½ hp disposal is available (please check with 

local authorities before ordering a unit with a disposal; some areas prohibit the use of disposals)

•  Hands-free foot pedal controls for cold/hot water faucet and optional formalin dispensing system

• Vacuum breaker-protected water supply• Appliances plug directly into the unit for convenient use• Ventilated base cabinet• Fume removal is efficient and quiet•  Each unit comes with an integral centimeter ruler on 

the front lip of the tabletop and magnetic instrument bar•  Built-in manifold rinse washes down wetted internal 

surfaces quickly•  Perforated grid plates for work surface (removable for 

easy cleaning)

Superior Quality•  Standard Type 304 or optional Type 316 stainless-steel 

construction•  Rugged design provides stability and is built tough to 

withstand years of extensive work without corrosion•  Perforated grid plates are standard Type 316 stainless-steel 

construction

Designed for Quick and Easy Installation• Workbench fits through a standard 32" (81.3cm) doorway•  Units connect to facility cold/hot water supplies 

and drains• Units are hard wired to facility electrical system• Workbench ships in one convenient assembly

Installed Depth from Back of Unit to Wall•  For the purpose of room planning, backs of fixed-height units 

can be flush to walls•  Elevating units require approximately 1" (2.54cm) clearance 

between the back of the unit and wall to accommodate height adjustment

Physical Specifications•   Overall Dimensions (H x W x D): 45 to 53 x 60 x 30" 

(114.3 to 134.6 x 152.4 x 76.2cm)•  Work surface height within range of 33 to 41" (83.8 to 

104.1cm); 36" (91.4cm) on fixed-height units unless customer-specified otherwise with order

•   Sink (W x L x D): 14 x 16 x 7.5" (35.6 x 40.6 x 19.1cm)•   Weight: Uncrated, 425 lb. (192.8kg); crated, 550 lb. (249.5kg)

Electrical Specifications•  110 –120V, 60Hz,  1Ph•  Draw 20 amps and require a separate 15 amp circuit for one 

hospital-grade duplex ground fault current interrupter (GFCI) receptacle

Plumbing Specifications•  ¾" (1.9cm) hot and cold water supply lines with shutoff  

valves and 1½" (3.8cm) drain line must be supplied•  ½" (1.3cm) industrial-grade flexible hoses with ¾" (1.9cm) 

female hose fittings are supplied for connection to water supply lines

•  1½" (3.8cm) I.D. reinforced flexible hose is provided for  connection to facility drain line

CertificationsUL/cUL (110-120V units only)

Included with product

Description Order Number

Work surface height within range of 33 to 41" (83.8 to 104.1cm); 36" (91.4cm) on fixed-height units unless customer-specified otherwise with order

Downdraft ventilation —

Ventilated base cabinet —

Removable sink —

Cold/hot water faucet with foot pedal controls —

Manifold rinse with manual control —

Hand spray —

Duplex GFCI electrical receptacle —

Centimeter ruler on front lip of tabletop —

Type 304 stainless steel construction —

Waste formalin collection system  with high-level alarm —

Magnetic instrument bar  (instruments not included) P104393

Ordering Information

Description Order Number

Fixed-height 110-120V, 60Hz, 1 Ph model with right-hand sink and foot pedal controls

Remote exhaust via facility duct  and blower (not included)

B21106

Elevating 110-120V, 60Hz, 1Ph model with right-hand sink and foot pedal controls

Remote exhaust via facility duct  and blower (not included)

B21107

Elevating and fixed-height units with left-hand sinks, manual controls and/or 220-240V, 50/60Hz, 1 Ph electrical ratings are available upon request.

Page 5: Thermo Scientific Shandon Pathology Workstations and ... · 4 Thermo Scientific Shandon Gross-Star Pathology Workbench Superior Functionality • Downdraft and/or back draft ventilation

5

If your facility can supply an exhaust duct and remote blower system that provides an airflow of 550 to 600 cfm (0.260 to .0283 cu. m/s), a ducted unit will best suit your needs. (Facility duct and remote blower by others; no filters.)

Validated Exhaust Specifications

Recommended exhaust airflow volume:  550 - 600cfm (0.260 to .0283 cu. m/s)Pressure loss through unit with standard downdraft:  0.15 - 0.18 in.w.g. (0.37 - 0.45mb)Pressure loss through unit with optional back draft:  0.27-0.33 in.w.g. (0.67 - 0.82 mb)

Average capture velocity with downdraft at 3" above work surface: 72-78 fpm (0.366 - 0.396m/s)

Average capture velocity with back draft at back of work surface: 156-170fpm (0.792-0.864m/s)

Average capture velocity with back draft at front of work surface: 59 - 64fpm (0.300 - 0.325m/s)

Remote Exhaust

Gross-Star™ Pathology Workstation Continued...

Choosing the Exhaust System to Fit Your LabRecirculating ExhaustFor existing labs or labs without facility exhaust, it may be necessary to filter and recirculate the air. Specify a unit with integral blowers and filters.

External ExhaustFor distance that do not exceed 20' (6.1m), you may choose a unit with integral blower and optional filters that may be connected to your facility’s exhaust duct for venting. (Facility duct and remote blower, if required, by others.)

Remote ExhaustIf your facility can supply an exhaust duct and remote blower system that provides an airflow of 550 to 600cfm (0.260 to 0.283 cu.m/s), a ducted unit will best suit your needs. (Facility duct and remote blower by others; no filters.)

Recirculating External* Remote

N/A N/A Recommended exhaust airflow volume:  550 – 600cfm  (0.260 – 0.0283cu. m/s)

N/A N/A Pressure loss through unit with downdraft: 0.07 – 0.08 in. w.g.(0.17 – 0.20 cu. mb)

N/A N/A Pressure loss through unit with back draft: 0.19 – 0.23 in. w.g.(0.47 – 0.57 cu. mb)

Average capture velocity with downdraft at 3" above work surface:

30 – 33 fpm(0.152 – 0.168 m/s)

55 – 59 fpm(0.279 – 0.300 m/s)

73 – 80fpm(0.371 – 0.406 m/s)

Average capture velocity with optional back draft at back of work surface:

80 – 84 fpm(0.406 – 0.427 m/s)

125 – 133 fpm(0.635 - 0.676 m/s)

157 – 172 fpm(0.798 - 0.874 m/s)

Average capture velocity with optional back draft at front of work surface:

40 – 44 fpm(0.203 – 0.224 m/s)

45 – 51 fpm(0.229 – 0.259 m/s)

60 – 66 fpm(0.406 – 0.427 m/s)

Average face velocity with optional hood assembly:

50 – 60 fpm(0.254 – 0.305 m/s)

85 – 95 fpm(0.432 – 0.483 m/s)

115 – 125 fpm(0.584 – 0.635 m/s)

Flexible Exhaust Duct Adapter for Elevating Units

It connects to your facility’s exhaust duct system to permit unit height adjustment. This piece ships separately and installs to the top of elevating external and remote exhaust units.

Replacement Filters Order Number

Replacement Filter Set–  Includes two formaldehyde-neutralizing (potassium permanganate) filters and two fine-particle filters

9990850

*    Data represents units without filters. With Filters, external exhaust capture and face velocities are similar to recirculating data

Validated Exhaust Specifications

Recirculating Exhaust–Use of filters is requiredExternal Exhaust–Use of filters if required for applicationRemote Exhaust–No filters are required

Factory Installed Options•  Waste formalin collection system with alarms feature both 

audible and visual alarms

Description Order Number

Disposal, ½ hp with rocker switch B2111

Back draft and downdraft fume  capture system B21216

Back draft fume capture system  (no downdraft) B21114

Fresh formalin dispensing system with foot pedal control and low-level alarm B21116

Task lamp (specify left or right side) B1001405

Type 316 stainless-steel construction Special order

Accessories

Description Order Number

Magnifier for B1001405 task lamp B1001326

Movable dictation recorder rack 10629

Movable requisition rack 105417

Photographic blue polyethylene  dissecting board B36115

Shelf for Thermo Scientific Shandon MicroWriter™ Cassette labeler  (require order number B10708)

B21215

Splash shield on flexible arm  (requires drilling for installation) B21201

Ventilated trash bin  (specify left or right side) B21115

Page 6: Thermo Scientific Shandon Pathology Workstations and ... · 4 Thermo Scientific Shandon Gross-Star Pathology Workbench Superior Functionality • Downdraft and/or back draft ventilation

6

Superior Functionality• Retractable acrylic side splash shields• Units with elevating or fixed-height work surface are available•  Elevating units have a user-adjustable work surface height 

from 33.5 to 45.5" (85.1 to 115.6cm)•  Fixed-height units have a work surface height that is  

factory set to your specification • Deep sink with cold/hot water faucet•  ½ hp disposal is standard (please check with local 

authorities before ordering a unit with disposal; some areas prohibit the use of disposals)

•  Hands-free proximity sensing controls for cold/hot water faucet, built-in table rinse, and disposal

• Abundant light directed to the work surface• Vacuum breaker-protected water supply• Appliances plug directly into the unit for convenient use•  Each unit comes complete with an integral centimeter ruler 

on front lip of tabletop, magnetic instrument bar and paper towel dispenser

• Built-in end table rinse washes down work surfaces quickly• Optional camera and monitor/keyboard brackets are available• Camera bracket slides along the width of the unit•  Monitor bracket is designed to hold a thin flat-screen display 

monitor•  Programmable microprocessor allows clock time to be 

changed and the filter replacement alarm to be reset (on proximity sensing controlled units only)

Three Ventilation System Options•  Recirculating exhaust models feature formaldehyde- 

neutralizing filters and an integral blower•  External exhaust models include an integral blower for 

short distances•  Remote exhaust models connect to the facility exhaust 

system

Superior Quality•  Standard Type 304 or optional Type 316 stainless-steel work 

surfaces and panels•  Extruded aluminum frame is designed to distribute weight 

evenly, stand up to heavy use, resist corrosion, add durability and minimize unit weight

•  Built tough to stand up to years of extensive work without corrosion

Thermo Scientific Shandon Grosslab Senior Pathology Workstation

Designed for Easy Shipping and Installation•  All units ship in two convenient assemblies that fit through a 

standard 32" (81.3cm) doorway•  The two assemblies link firmly with easy-to-assemble inte-

gral cam latches•  Units connect to the facility cold/hot water supplies and 

drain• Units are hard wired to the facility electrical system

Physical Specifications•  Overall Dimensions (H x W): 81 to 93 x 60"  

(205.7 to 236.2 x 152.4cm)•  Depth shown below (see Installed Depth from Front of Unit 

to Wall)•  Work surface height within range of 33.5 to 45.5" (85.1 to 

115.6 cm); 36" (91.4cm) on fixed-height units unless  customer-specified otherwise with order

• Sink (L x W x D): 14 x 12 x 6" (35.6 x 30.5 x 15.2cm)•  Top Piece Weight: Uncrated, 285 lb. (129.3kg); crated, 375 

lb. (170.1kg)•  Bottom Piece Weight: Uncrated, 475 lb. (215.5kg); crated, 

545 lb. (247.2kg)

Electrical Specifications• 110 – 120V, 60Hz, 1Ph•  Draw 20 amps and require a separate 15-amp circuit for one 

hospital-grade duplex ground fault current interrupter (GFCI) receptacle

Plumbing Specifications•  ¾" (1.9cm) hot and cold water supply lines with shutoff 

valves and 1½" (3.8cm) drain line must be supplied•  ½" (1.3cm) industrial-grade flexible hoses with ¾" (1.9cm) 

female hose fittings are supplied for connection to water supply lines

•  1½" (3.8cm) I.D. reinforced flexible hose is provided for  connection to facility drain line

CertificationsUL/cUL (110-120V units only)

Installed Depth from Front of Unit to Wall• Elevating, recirculating units: 32.5" (82.6cm)• Elevating, external exhaust units: 38" (96.5cm)• Elevating, remote exhaust units: 38" (96.5cm)• Fixed-height, recirculating units: 32.5" (82.6cm)• Fixed-height, external exhaust units: 36.5" (92.7cm)• Fixed-height, remote exhaust units: 36.5" (92.7cm)

Included with product

Description Order Number

Work surface height within range of 33.5 to 45.5" (85.1 to 115.6 cm); 36" (91.4cm) on fixed-height units unless customer-specified otherwise with order

Louvered back draft ventilation —

Sink —

Cold/hot water faucet with proximity sensing controls (proximity sensing controlled units only) or manual controls (manually controlled units only)

Built-in table rinse with proximity sensing control (proximity sensing controlled units only) or manual control (manually controlled units only)

Disposal, 1/2 hp with proximity sensing control (proximity sensing controlled units only) or manual control (manually controlled units only)

Page 7: Thermo Scientific Shandon Pathology Workstations and ... · 4 Thermo Scientific Shandon Gross-Star Pathology Workbench Superior Functionality • Downdraft and/or back draft ventilation

7

Hand-free proximity sensing controls for cold/hot water faucet, table rinse, and disposal.

Hand spray —

Duplex GFCI Electrical Receptacle —

Centimeter ruler on front lip of tabletop —

Fixed lower shelf —

Fixed upper shelf —

Fluorescent light —

Type 304 stainless-steel tabletop and panels —

Extruded aluminum frame —

Retractable acrylic side splash shields —

Programmable microprocessor for date, time and filter replacement alarm (prox-imity sensing controlled units only)

Tea strainer faucet with manual control, bracket and tea strainer —

Magnifier on flexible arm 104404

Magnetic instrument bar  (instruments not included) P104393

Towel dispenser for C-fold towels 1070214

C-fold towels 104401

Ordering Information

Description Order NumberElevating 110-120V, 60Hz, 1Ph models with right-hand sink and proximity sensing controls

Recirculating Exhaust via filters and  integral blower

9700

External Exhaust via integral blower and  facility duct (20' max.; not included)

97001

Remote Exhaust via facility duct and  blower (not included)

97002

Fixed-height 110-120V, 60Hz, 1Ph models with right-hand sink and proximity sensing controls.

Recirculating Exhaust via filters and integral blower

97003

External Exhaust via integral blower and  facility duct (20' max.; not included)

97004

Remote Exhaust via facility duct and blower (not included)

97005

Elevating 110-120V, 60Hz, 1Ph models with right-hand sink and manual controls

Recirculating Exhaust via filters and  integral blower

97006

External Exhaust via integral blower and  facility duct (20' max.; not included)

97007

Remote Exhaust via facility duct and  blower (not included)

97008

Fixed-height 110-120V, 60Hz, 1Ph models with right-hand sink and manual controls

Recirculating Exhaust via filters and  integral blower

97009

External Exhaust via integral blower and  facility duct (20' max.; not included)

970010

Remote Exhaust via facility duct and  blower (not included)

970011

Elevating and fixed-height units with left-hand sinks, foot pedal controls and/or 220-240V, 50/60Hz 1Ph electrical rating are available upon request.

Factory Installed Options

Description Order Number

Task lamp (specify left or right side) B1005102

Type 316 stainless-steel construction Special order

Accessories

Description Order Number

Camera bracket 10661

Fresh formalin dispensing carboy 104395

Magnifier for B1005102 task lamp B1001326

Movable dictation recorder rack 10629

Movable requisition rack 105417

Photographic blue polyethylene  dissecting board B36115

Shelf for Thermo Scientific Shandon MicroWriter™ Cassette labeler  (requires order number B10708)

B21229

Splash shield on flexible arm  (requires drilling for installation) B21201

Thin monitor/keyboard bracket B10708

Ventilated trash bin (specify left or right side)

B21115

Choosing the Exhaust System to Fit Your LabRecirculating ExhaustFor existing labs or labs without facility exhaust, it may be neces-sary to filter and recirculate the air. Specify a unit with integral blowers and filters.

External ExhaustFor distances that do not exceed 20' (6.1m), you may choose a unit with integral blower and optional filters that may be con-nected to your facility’s exhaust duct for venting. (Facility duct and remote blower, if required, by others.)

Remote ExhaustIf your facility can supply an exhaust duct and remote blower system that provides an airflow of 500cfm (0.236 cu.m/s), a ducted unit will best suit your needs. (Facility duct and remote blower by others; no filters.)

Validated Exhaust Specifications

Recirculating External Remote

 N/A N/A Recommended exhaust airflow volume:  500 cfm (0.236 cu. m/s)

N/A N/A Pressure loss through unit: 0.41 in. w.g. (1.02 mb)

Average capture velocity at vented area with side panels:

89 fpm (0.452 m/s)

106 fpm       Without(0.538 m/s)   Filters

128 fpm(650 m/s)

Fro 80 fpm          With(0.406 m/s)   Filters

Average capture velocity at front of unit with side panels:

38 fpm(0.193 m/s)

55 fpm         Without (0.279 m/s)   Filters

22 fpm         With(0.112 m/s)   Filters

69 fpm(0.351 m/s)

Recirculating Exhaust – Use of filters is requiredExternal Exhaust – Use filters if required for applicationRemote Exhaust – No filters are required

Replacement Filters Order Number

Replacement Filter Set – Includes two formaldehyde-neutralizing (potassium permanganate) filters and two fine-particle filters

9990850

Units have 6" (15.2cm) deep sinks, tea strainer and separate faucet for rinsing curettings and other small specimens.

Table rinse comes standard.

Flexible exhaust duct adapter for elevating units ships separately and installs to the back of elevating external and remote exhaust units. It con-nects to your facility’s exhaust duct system, permitting the unit to elevate.

Page 8: Thermo Scientific Shandon Pathology Workstations and ... · 4 Thermo Scientific Shandon Gross-Star Pathology Workbench Superior Functionality • Downdraft and/or back draft ventilation

8

Features•  Rapid positive drainage•  Quick and easy installation•  Three ventilation system options: recirculating exhaust, 

external exhaust, or remote exhaust•  Back draft ventilation for efficient and quiet fumes capture 

across work surface•  Ergonomically designed to be low to the counter•  Use with optional stand (10456) to free up counter space•  Programmable microprocessor allows clock time to be 

changed and the filter replacement alarm to be reset•  Optional splash shield (B21201) protects the user while  

dissecting specimens•  Flat stainless-steel work surface include three removable 

perforated grid plates•  Abundant fluorescent light is directed to the work surface•  Vacuum breaker-protected water supply•  Hands-free proximity sensing control for cold water faucet; 

also has manual override capability•  Appliances plug directly into the unit for convenient use•  Each unit comes with an integral centimeter ruler on the 

front lip of the tabletop, magnetic instrument bar and towel dispenser

•  Standard Type 304 or optional Type 316 stainless-steel construction

Physical Specifications• Overall Dimensions (H x W x D):      Recirculating Exhaust: 45.75 x 48 x 28"  

(116.2 x 121.9 x 71.1cm)     External Exhaust: 52.75 x 48 x 28" (134 x 121.9 x 71.1cm)     Remote Exhaust: 52.75 x 48 x 28" (134 x 121.9 x 71.1cm)• Work Surface Height: 1.75" (4.4cm) above benchtop•  Recommended Depth: 29" (73.7cm) from front of unit to wall• Sink (W x L x D): 18 x 6 x 4" (45.7 x 15.2 x 10.2cm)•  Weight: Uncrated, 300 lb. (136.1kg); crated, 350 lb. (158.8kg)

Electrical Specifications•  110-120V, 60Hz, 1Ph•  One IEC 320 power entry module and one point-of-use 

power cord are supplied•  Facility electrical receptacle with 15 amp circuit is required 

for use with power cord•  Draw 15 amps including the two hospital-grade duplex 

ground fault circuit interrupter (GFCI) receptacles

Plumbing Specifications

Thermo Scientific Shandon GrosslabJunior Benchtop Workstation

•  One ½" (1.3cm) industrial-grade flexible hose with ¾" (1.9cm) female hose fitting is supplied for connection to the facility cold water supply line

•  One ¾" (1.9cm) NPT connection and 1" (2.5cm) I.D. reinforced flexible hose is supplied for connection to the facility drain line

CertificationsUL/cUL (110-120V units only)

Included With Product 

Description Order Number

Work surface height 1.75" (4.4cm)  above benchtop —

Louvered back draft ventilation —

Centered sink on lower shelf —

Cold water faucet with rocker switch for user choice of proximity sensing or manual control

Deluxe hand spray —

Two duplex GFCI electrical receptacles —

Centimeter ruler on front lip of tabletop —

Fixed lower shelf —

Fixed upper shelf —

Fluorescent light —

Type 304 stainless-steel construction —

Programmable microprocessor for date, time and filter —

Magnetic instrument bar  (instruments not included) P104393

Towel dispenser for C-fold towels 1070214

C-fold towels 104401

Ordering Information

Description Order NumberBenchtop 110-120V, 60Hz, 1Ph models with proximity  sensing/manual override controls for cold water faucet

Recirculating Exhaust via filters and  integral blower

9600

External Exhaust via integral blower  and facility duct (20' max.; not included)

96001

Remote Exhaust via facility duct and  blower (not included)

96002

Benchtop units with 220-240V, 50/60Hz, 1Ph electrical ratings available upon request.

Factory Installed Options

Description Order Number

Type 316 stainless-steel construction Special order

Page 9: Thermo Scientific Shandon Pathology Workstations and ... · 4 Thermo Scientific Shandon Gross-Star Pathology Workbench Superior Functionality • Downdraft and/or back draft ventilation

9

Accessories•   Stand with extruded aluminum frame and stainless-steel 

shelf with back panel (stand is height adjustable from  28 to 42" (71 to 107cm) during installation)

Description Order Number

Fluorescent magnifier lamp 1001755

Fresh formalin dispensing carboy 104395

Movable dictation recorder rack 10629

Movable requisition rack 105417

Movable tea strainer bracket and tea strainer (for use with sink and water faucet)

B21237

Photographic blue polyethylene  dissecting board B36115

Splash shield on flexible arm  (requires drilling for installation) B21201

Stand with extruded aluminum frame, stainless-steel shelf and adjustable  height from 28 to 42" (71.1 to 106.7cm)

10456

Optional Stand (10456) transforms the benchtop unit into a stand-alone workstation. Sturdy, extruded aluminum frame with stainless-steel shelf can be height adjusted from 28 to 42" (71.1 to 106.7cm)

Choosing the Exhaust System to Fit Your Lab

Recirculating ExhaustFor existing labs or labs without facility exhaust, it may be neces-sary to filter and recirculate the air. Specify a unit with integral blowers and filters.

External ExhaustFor distances that do not exceed 20' (6.1m), you may choose a unit with integral blower and optional filters that may be connect-ed to your facility’s duct for venting. (Facility duct and remote blower, if required, by others.)

Remote Exhaust If your facility can supply an exhaust duct and remote blower system that provides an airflow of 400cfm (0.189 cu. m/s), a ducted unit will best suit your needs. (Facility duct and remote blower, no filters).

Validated Exhaust Specifications

Recirculating External Remote

 N/A N/A

Recommended exhaust airflow volume: 400 cfm (0.189cu. m/s) 

N/A N/APressure loss through unit: 1.15 in. w.g. (2.87 mb)

Average capture velocity at vented area:

119 –121fpm (0.604 – 0.615 m/s)

122–123 fpm  (0.620 – 0.625 m/s)

148 fpm  (0.752 m/s)

Average capture velocity at front of unit:

10 fpm (0.051m/s) 10–13 fpm  (0.051– 0.066 m/s)

15 fpm  (0.076 m/s)

Recirculating Exhaust – Use of filters is requiredExternal Exhaust – Use filters if required for applicationRemote Exhaust – No filters are required

Replacement Filters Order Number

Replacement Filter Set–    Includes two formaldehyde-neutralizing (potassium permanganate) filters and two fine-particle filters

1001618

To minimize contamination and maximize convenience, Grosslab Junior Benchtop units feature a hands-free proximity sensing control for cold water. 

Filter drawers are located in the front of the unit for easy access.

An optional magnifier lamp mounts on the side of the unit for added convenience in dis-secting delicate specimens.

Page 10: Thermo Scientific Shandon Pathology Workstations and ... · 4 Thermo Scientific Shandon Gross-Star Pathology Workbench Superior Functionality • Downdraft and/or back draft ventilation

10

Thermo Scientific Shandon Grosslab Junior Stand-Alone Workstation

Features• Rapid positive drainage• Quick and easy installation•  Three ventilation system options: recirculating exhaust, 

external exhaust, or remote exhaust•  Back draft ventilation for efficient and quiet fumes capture 

across work surface•  Programmable microprocessor allows clock time to be 

changed and the filter replacement alarm to be reset•  Optional splash shield (B21201) protects the user while  

dissecting specimens•  Abundant fluorescent light is directed to the work surface• Vacuum breaker-protected water supply• Appliances plug directly into the unit for convenient use•  Each unit comes with an integral centimeter ruler on the 

front lip of the tabletop, magnetic instrument bar, and  towel dispenser

•  Standard Type 304 or optional Type 316 stainless-steel construction

Physical Specifications• Overall Dimensions (H x W x D)

Recirculating exhaust: 78.5 x 48 x 28"  (199.4 x 121.9 x 71.1cm)External exhaust: 85.5 x 48 x 28" (217.2 x 121.9 x 71.1cm)Remote exhaust: 85.5 x 48 x 28" (217.2 x 121.9 x 71.1cm)

• Work Surface Height: 36" (91.4cm)• Sink (L x W x D): 14 x 129.75" (35.6 x 30.5 x 24.8cm) • Weight: Uncrated, 500lb. (226.8kg); crated, 600lb, (272.2kg) 

Electrical Specifications• 110-120V, 60Hz, 1Ph•  Two IEC 320 power entry modules and two point-of-use 

power cords are supplied•  Facility electrical receptacles with 15 amp circuits are  

required for use with each power cord•  Draw 15 amp including the two hospital-grade duplex 

ground fault circuit interrupter (GFCI) receptacles

Plumbing Specifications•  Two ½" (1.3cm) industrial-grade flexible hoses with ¾" 

(1.9cm) female hose fittings are supplied for connection to the facility cold and hot water supply line

•  1½" (3.8cm) I.D. reinforced flexible hose is supplied for  connection to the facility drain line

Certifications•  UL/cUL (110-120V units only)

Included with Product

Description Order Number

Work surface height: 36" (91.4cm)  —

Louvered back draft ventilation —

Sink —

Cold/hot water faucet with manual control —

Disposal, ½ hp with manual control —

Hand spray combined with cold/hot water faucet —

Two duplex GFCI electrical receptacles —

Centimeter ruler on front lip of tabletop —

Fixed lower shelf —

Fixed upper shelf —

Fluorescent light —

Type 304 stainless-steel construction —

Programmable microprocessor for date, time and filter —

Magnetic instrument bar  (instruments not included) P104393

Towel dispenser for C-fold towels 1070214

C-fold towels 104401

Ordering Information

Description Order Number

Stand-Alone 110-120V, 60Hz, 1Ph models with right-hand sink and manual controls

Recirculating Exhaust via filters and integral blower

96003

External exhaust via integral blower  and facility duct (20' max.; not included)

96004

Remote exhaust via facility duct and blower (not included)

96005

Stand-Alone units with left-hand sinks, foot pedal controls and/or 220-240V, 50/60Hz, 1Ph electrical ratings are available upon request.

Page 11: Thermo Scientific Shandon Pathology Workstations and ... · 4 Thermo Scientific Shandon Gross-Star Pathology Workbench Superior Functionality • Downdraft and/or back draft ventilation

11

Choosing the Exhaust System to Fit Your Lab

Recirculating ExhaustFor existing labs or labs without facility exhaust, it may be necessary to filter and recirculate the air. Specify a unit with integral blowers and filters.

External ExhaustFor distances that do not exceed 20' (6.1m), you may choose a unit with integral blower and optional filters that may be connected to your facility’s duct for venting. (Facility duct and remote blower, if required, by others.)

Remote Exhaust If your facility can supply an exhaust duct and remote blower system that provides an airflow of 400cfm (0.189 cu. m/s), a ducted unit will best suit your needs. (Facility duct and remote blower, no filters.)

Validated Exhaust Specifications

Recirculating External Remote

 N/A N/A

Recommended exhaust airflow volume: 400 cfm (0.189cu. m/s) 

N/A N/APressure loss through unit: 1.15 in. w.g. (2.87 mb)

Average capture velocity at vented area:

119 –121fpm (0.604 – 0.615 m/s)

122–123 fpm  (0.620 – 0.625 m/s)

148 fpm  (0.752 m/s)

Average capture velocity at front of unit:

10 fpm (0.051m/s) 10–13 fpm  (0.051– 0.066 m/s)

15 fpm  (0.076 m/s)

Recirculating Exhaust–Use of filters is requiredExternal Exhaust–Use of filters is required for applicationRemote Exhaust–No filters are required

Replacement Filters Order Number

Replacement Filter Set –    Includes two formaldehyde-neutralizing (potassium permanganate) filters and two fine-particle filters

1001618

The Grosslab Junior Stand-Alone models feature a hand spray combined with the faucet.

Factory Installed Options

Description Order Number

Type 316 stainless-steel construction Special order

Accessories

Description Order Number

Fluorescent magnifier lamp 1001755

Fresh formalin dispensing carboy 104395

Movable tea strainer bracket and tea stainer (for use with sink and water faucet)

B21247

Movable dictation recorder rack 10629

Movable requisition rack 105417

Photographic blue polyethylene  dissecting board

B36115

Splash shield on flexible arm  (requires drilling for installation)

B21201

Ventilated trash bin (specify left or right side)

B21115

Page 12: Thermo Scientific Shandon Pathology Workstations and ... · 4 Thermo Scientific Shandon Gross-Star Pathology Workbench Superior Functionality • Downdraft and/or back draft ventilation

© 2009 Thermo Fisher Scientific Inc. All rights reserved. Suresorb is a trademark of National Nonwovens. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries.

Thermo Scientific Grossing Consumables

Biopsy Bags  

•   Allow unrestricted fluid movement around tissue. •   Reduce risk of small specimen loss.•   Reduce reagent carry-over and pressure artifact 

often found with sponges.•   Peel-open bag conveniently exposes specimen 

for rapid removal•   Acid resistant biopsy bags feature all the benefits  

of nylon biopsy bags, plus offer acid-resistance  for decalcification.

•   Small Biopsy Bags measure 1.2" x 1.7"  (31 x 43 mm)

•   Medium Biopsy Bags measure 1.8" x 2.6"  (45 x 65 mm)

•   Large Biopsy Bags measure 3" x 3.5"  (75 x 85 mm)

Dissecting Instruments with Case •  Kit is available with complete set of instruments. •   Case is also available without instruments.•   Photograph may not represent actual set of instru-

ments included with order number 9996969 (kit is subject to change without notice).

Polyethylene Dissecting BoardsWill not dull fine surgical cutting edges.

•   Durable, easy-to-clean 0.75" (1.9cm) thick polyethylene will not dull fine surgical cutting edges.

•   White opaque surface provides an excellent back-ground for cutting surgical or research specimens.

•   Photographic blue surface allows specimens to be photographed directly on the board; no need for removal to another location.

•   Large board measures (L x W x H) 16 x 23 x 0.75" (40.6 x 58.4 x 1.9cm) 

•   Small board measures (L x W x H) 12 x 16 x 0.75"   (40.6 x 58.4 x 1.9cm) 

Thermo Scientific Grossing Accessories

Description Size Order Number

Instrument case  (Does not include instruments)

12.75 x 9.5 x 2.5"  (32.4 x 24.1 x 6.4 cm) 1001382

Instrument case  with instruments

12.75 x 9.5 x 2.5"  (32.4 x 24.1 x 6.4 cm) 9996969

See products catalog for complete list of dissecting instruments

Description Order Number

WhiteLarge BoardSmall Board

36114361191

Photographic BlueLarge BoardSmall Board

B36115B361192

Description Pkg/Qty Order Number

Nylon Biopsy Bags, Small 1,000/pk 6774010

Nylon Biopsy Bags, Medium 1,000/pk 6774009

Nylon Biopsy Bags, Large 500/pk 6774011

Acid-Resistant Biopsy Bags, Small 250/pk 6774051

Acid-Resistant Biopsy Bags, Medium 250/pk 6774050

Acid-Resistant Biopsy Bags, Large 250/pk 6774052

Shandon TBD-1 Decalcifier  Rapid hydrochloric acid decalcifier for processing bone marrow biopsies in as little as 15-30 min.• Thin pieces of dense bone process in 3-12 hrs.•   Permits utilization of routine end point tests, such as 

calcium oxalate•   Added ingredients protect cells from actions of acids.

Size Qty Order Number

1 L (0.26 gal) 2/cs. 6764001

1 L (0.26 gal) 4/cs.  6764002

Shandon TBD-2 Decalcifier  Formic acid decalcifier for gentle, longer-term processing.

•   Go up to 48 hrs. past end point without damaging specimens.

•   Permits utilization of routine end point tests, such as calcium oxalate.

•   Added ingredients protect cells from action of acid.

Description Pkg/Qty Order Number

1 L (0.26 gal) 2/cs. 6764003

1 L (0.26 gal) 4/cs.  6764004

Suresorb® Clinical Pads and Formalin Neutral-izer PadsIdeal for containment and disposal of body fluids containing Hepatitis B virus, AIDS/HIV and other known pathogens.  

•   Patented fiber absorbs and then locks in liquids so work area stays drier. •  Resists tearing, even when saturated.•  Clinical Pads applications include surgical cutting board pads, dissecting pads, 

autopsy table pads, and liners for body traps and cadaver bags.•   Formalidehyde Neutralizer Pads reduce exposure by chemically bonding with 

formaldehyde, resulting in the encapsulation of vapors–ideal for grossing area and autopsy work.

Description Size Oty. Order No.

Autopsy Table Pad 45 x 80" (114.3 x 203cm) 10/cs. 9833

Dissecting Table Pad 22 x 20" (55.9 x 50.8cm) 50/cs. 9834

Surgical Cutting Board Pad 22 x 20" (59.9 x 50.8cm) 50/cs. 9835

Morgue Trough Pad 18 x 72" (45.7 x 182.8cm) 50/cs. 9836

Morgue Stretcher Pad 24 x 72" (61 x 182.8cm) 50/cs.  9837

Biopsy Sample Pad 8 x 10" (20.3 x 25.4cm) 400/cs.100/cs.

541154111

Formaldehyde  Neutralizer Pad

8 x 10" (20.3 x 25.4cm)

16 x 20" (40.6 x 50.8cm)

400/cs.50/cs.

100/cs.25/cs.

5641564115643

56431

4481 Campus Drive www.thermo.com/pathologyAnatomical Pathology (800) 522-7270Kalamazoo, MI 49008