THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User...

28
THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846

Transcript of THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User...

Page 1: THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846

THERMO-HYGROMETER TERMO-HIGRÓMETRO

E N G L I S H User Manual

E S PA Ñ O L Manual de Instrucciones

CA846

Page 2: THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846

Statement of Compliance

Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments certifies that this instrument has been calibrated using standards and instruments traceable to international standards.

We guarantee that at the time of shipping your instrument has met its published specifications.

An NIST traceable certificate may be requested at the time of purchase, or obtained by returning the instrument to our repair and calibration facility, for a nominal charge.

The recommended calibration interval for this instrument is 12 months and begins on the date of receipt by the customer. For recalibration, please use our calibration services. Refer to our repair and calibration section at www.aemc.com.

Serial #: ________________________________

Catalog #: 2121.24

Model #: CA846

Please fill in the appropriate date as indicated:

Date Received: _________________________________

Date Calibration Due: _______________________

Chauvin Arnoux®, Inc.d.b.a AEMC® Instrumentswww.aemc.com

Page 3: THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846

Thermo-Hygrometer Model CA846 1

Table of Contents

ENGLISH .................................................................................................1ESPAÑOL ..............................................................................................13

1. INTRODUCTION ............................................................................... 21.1 International Electrical Symbols ................................................21.2 DefinitionofMeasurementCategories .....................................31.3 ReceivingYourShipment ..........................................................31.4 OrderingInformation .................................................................3

2. PRODUCT FEATURES ...................................................................... 42.1 Description ................................................................................42.2 PushButtons ............................................................................5

2.2.1 Center(Yellow)FunctionSwitch ...................................5

2.2.2 Back-Light and°C/°FButton ...................................52.2.3 MAXButton ...................................................................52.2.4 HOLDButton ................................................................5

3. SPECIFICATIONS............................................................................. 63.1 EnvironmentalSpecifications ....................................................63.2 MechanicalSpecifications ........................................................73.3 SafetySpecifications ................................................................7

4. OPERATION .................................................................................... 84.1 Recommendations ....................................................................84.2 OperatingtheModelCA846 .....................................................8

5. MAINTENANCE ............................................................................... 95.1 ReplacingtheBattery ...............................................................95.2 Cleaning ....................................................................................9

RepairandCalibration ...........................................................................10

Technical and Sales Assistance ............................................................10

Limited Warranty ...................................................................................11

WarrantyRepairs ...................................................................................11

Page 4: THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846

2 Thermo-Hygrometer Model CA846

CHAPTER 1

INTRODUCTION

Warning

• Do not connect to, or touch, any electrical circuit with theThermo-Hygrometer.

• Toavoidinjuryorfirehazard,donotoperatethisproductinanexplosiveatmosphereorenvironment.

• Remove (unscrew) the protective metal tube covering thesensorheadwhenusingtheThermo-Hygrometer.

• DonotimmersetheThermo-Hygrometersensorheadintoliq-uids-thismaycausepermanentdamagetothesensors.

• Screwontheprotectivemetal tubecoveringthesensorheadwhennotusingtheThermo-Hygrometer.

1.1 International Electrical SymbolsThis symbol signifies that the instrument is protected by double or reinforced insulation.This symbol on the instrument indicates a WARNING and that the operator must refer to the user manual for instructions before operating the instrument. In this manual, the symbol preceding instructions indicates that if the instructions are not followed, bodily injury, installation/sample and product damage may result.Risk of electric shock. The voltage at the parts marked with this symbol may be dangerous.This symbol refers to a type A current sensor. This symbol signifies that application around and removal from HAZARDOUS LIVE conductors is permitted.

In conformity with WEEE 2002/96/EC

Page 5: THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846

Thermo-Hygrometer Model CA846 3

1.2 Definition of Measurement Categories

Cat. II: Formeasurements performed on circuits directly connected totheelectricaldistributionsystem.Examplesaremeasurementsonhouseholdappliancesorportabletools.

Cat. III: For measurements performed in the building installation atthe distribution level such as on hardwired equipment in fixedinstallationandcircuitbreakers.

Cat. IV: For measurements performed at the primary electrical supply(<1000V) such as on primary overcurrent protection devices,ripplecontrolunits,ormeters.

1.3 Receiving Your ShipmentUponreceivingyourshipment,makesure that thecontentsareconsis-tentwith thepacking list.Notifyyourdistributorofanymissing items. Iftheequipmentappearstobedamaged,fileaclaimimmediatelywiththecarrierandnotifyyourdistributoratonce,givingadetaileddescriptionofanydamage.Savethedamagedpackingcontainertosubstantiateyourclaim.

1.4 Ordering InformationThermo-Hygrometer Model CA846 ..................................Cat. #2121.24Includes meter, shockproof holster, 9V battery and user manual.

Page 6: THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846

4 Thermo-Hygrometer Model CA846

CHAPTER 2

PRODUCT FEATURES

2.1 DescriptionTheThermo-HygrometerModelCA846isaportable,compactdigitalmeterdesignedforsimplicityandone-handoperation.ThemeterusesanNTCasthetemperaturesensorprovidingexcellentresponsetimetochangesintemperature,goodrepeatabilityandaccuratereadings.

TheModelCA846alsoutilizesathin-filmpolymer-capacitivetyperelativehumidity sensorashygrometersensor,offeringexcellent recovery from100%moistureandfastresponsetimeanddurability.

1. Temperature/humiditysensorwithprotectivesensorcover

2. 3½digitdisplay

3. MAXbutton

4. °C/°Fselector&backlight

5. HOLDbutton

6. Power/mode selector

1

2

3 5

64

Page 7: THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846

Thermo-Hygrometer Model CA846 5

2.2 Push Buttons

2.2.1 Center (Yellow) Function Switch

TurnsONtheThermo-Hygrometerandselectsthe%RHor°C/°Fsetting.SlidethebuttontoOFFafteruse.

2.2.2 Back-Light and °C/°F Button

• Pressthe buttontoturntheBack-LightON.

• Pressthe buttonagaintoturntheBack-LightOFF.

• Pressthe buttonfor2secondstochangethetemperaturescaleto°Cor°F.Thetemperaturescale°Cor°Fisdisplayedinthelowerrighthandcornerofthedisplay.

2.2.3 MAX Button• PresstheMAXbuttontoentertheMAXmode.The“MAX”annunciator

appearsintheupperrighthandcornerofthedisplay.• Theselectedrange(%RHor°C/°F)recordsandupdatesthemaximum

absolutevalues.• PresstheMAXbuttonagaintoexittheMAX-recordingmode(“MAX”

goesout).• TheHOLDbuttonmaybeusedintheMAXmodeto“Freeze”(nolonger

updates)theMAXmeasurementonthedisplay.

2.2.4 HOLD ButtonTheHoldbutton“freezes”thereadingonthedisplay.Pressthe“HOLD”buttontotoggle(activate/release)HOLD.IntheHOLDmode,the“HOLD”annunciatorisdisplayedintheupperpartoftheLCDdisplayandthelastreadingisdisplayeduntilreleased.

Page 8: THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846

6 Thermo-Hygrometer Model CA846

CHAPTER 3

SPECIFICATIONS

3.1 Environmental SpecificationsTemperature Scale:Celsius(°C)orFahrenheit(°F)user-selectable

Temperature Sensor: NTC

Measurement Range:-4°to140°F,-20°to60°C

Resolution: 0.1°F/°C

Accuracy: -4° to 32°F ± 2°F (-20° to 0°C ± 1°C)32° to 140°F ± 1°F (0° to 60°C ± 0.5°C)

Temperature Coefficient:0.1timestheapplicableaccuracyspecificationper°Cfrom0°to18°Cand28°to50°C(32°to64°Fand82°to122°F)

Humidity Sensor:Electroniccapacitancepolymerfilmsensor.(Thesensorisunaffectedbywatercondensation,andisimmunetomostreagentvapors)

Measurement Range: 0% to 100% RH

Resolution: 0.1% RH

Accuracy (@ 25°C): 10%-90% RH ± 5.0% 0%-10% RH; 90% to 100% RH ± 10.0%

Sensor Response Time for 90% of Range:60stypical

Sensor Stability:±2%RH,2yearstypical

Sensor Hysterisis (10% to 90% to 10% RH):±1%RHtypical

Sensor Temperature Dependence:Negligiblefrom32°to140°F(0°to60°C)

Operating Temperature:32° to 122°F (0°C to 50°C) at < 80% RH

Storage Temperature:-4°to140°F(-20°to60°C),0to80%RHwithbatteryremoved

Page 9: THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846

Thermo-Hygrometer Model CA846 7

Accuracy:Statedaccuracyat23°C±5°C,<90%RH

Altitude: 2000m max

3.2 Mechanical SpecificationsDisplay:3½digitliquidcrystaldisplay(LCD)withmaximumreadingof1999

Over-Range:“OL”isdisplayed

Low Battery Indication: The isdisplayedwhenthebatteryvoltagedropsbelowtherequiredlevel

Sample Rate: 2.5timespersecond,nominal

Input Protection:24VDCor24Vrmsmaximuminputvoltageonanyinput

Power Supply:Standard9Vbattery(NEDA1604,IEC6F22006P,orequivalent)

Battery Life:200hourstypicalwithcarbonzincbattery

Dimensions:6.81 x 2.38 x 1.5" (173 x 60.5 x 38mm)

Weight:Approx7oz(197g)includingbattery

3.3 Safety Specifications

EN61010-1(1995-A2),ProtectionClassIII

OvervoltageCategory(CATIII,24V),PollutionDegree2

Indoor Use

*All specifications are subject to change without notice

Page 10: THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846

8 Thermo-Hygrometer Model CA846

CHAPTER 4

OPERATION

4.1 Recommendations• Forreliablemeasurements,letthereadingsstabilize.Thehygrometer

andtemperaturesensormustreachequilibriumwiththemediummea-sured.

• Avoid temperature measurement errors induced by too short mea-surementtime,sunshineduringthemeasurement,heating,coldouterwalls,airdraft(e.g.fans),radiatingsourcesincludinghandand/orbodyheat,etc.

• Avoidhumiditymeasurementerrorsinducedbysteam,watersplashes,drippingwaterorcondensationonthesensor,etc.

• Avoidsensorcontaminationinducedbyparticlesintheairormeasure-mentsinpowderlikesubstances.Contaminationmaybeavoidedbymeasuringthroughafilter(usersupplied).Thefiltermustbecleanedorreplacedperiodically,dependinguponthedegreeofcontaminationatthemeasurementsite.

4.2 Operating the Model CA8461. Unscrewtheprotectivemetaltubecoveringthesensor.

2. Setthepowerswitchtothedesired%RHor°C/°Frange.

3. Letthereading(s)stabilize(%RHtakesatleast60secondstoreach90%).

4. Readthedisplay.

5. Afteruse,screwtheprotectivemetaltubebackontothesensor.

6. TurntheinstrumentOFFwhenfinished.

Page 11: THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846

Thermo-Hygrometer Model CA846 9

CHAPTER 5

MAINTENANCE

Use only factory specified replacement parts.AEMC® will not be held responsible for anyaccident, incident, ormalfunction followinga repairdoneotherthanbyitsservicecenterorbyanapprovedrepaircenter.

5.1 Replacing the Battery The symbolappearsontheLCDdisplaywhenreplacementisneeded.Replacewithastandard9Vbattery(NEDA1604,IEC6F22).

Toreplacethebattery:• TurntheThermo-HygrometerOFF.• Removetherubberholster.• Removethescrewfromthebackofthemeterandliftoffthebattery

cover.• Replacethebattery,thenputtherearcoverandholsterbackon.

5.2 Cleaning• Useasoftclothlightlydampenedwithsoapywater.

• Rinsewithadampclothandthendrywithadrycloth.

• Donotuseanyabrasivesorsolvents.

• Donotletanyliquidenterthecaseorsensorarea.

Page 12: THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846

10 Thermo-Hygrometer Model CA846

Repair and CalibrationToensurethatyourinstrumentmeetsfactoryspecifications,werecommendthatitbescheduledbacktoourfactoryServiceCenteratone-yearintervalsforrecalibration,orasrequiredbyotherstandardsorinternalprocedures.

For instrument repair and calibration:Youmust contactourServiceCenter foraCustomerServiceAuthorizationNumber(CSA#).Thiswillensurethatwhenyourinstrumentarrives,itwillbetrackedandprocessedpromptly.PleasewritetheCSA#ontheoutsideoftheshipping container. If the instrument is returned for calibration,weneed toknowifyouwantastandardcalibration,oracalibrationtraceabletoN.I.S.T.(Includescalibrationcertificateplusrecordedcalibrationdata).

Ship To: ChauvinArnoux®,Inc.d.b.a. AEMC®Instruments15 Faraday DriveDover,NH03820USATel: (800) 945-2362 (Ext. 360)

(603) 749-6434 (Ext. 360)Fax: (603) 742-2346 or (603) [email protected]

(Orcontactyourauthorizeddistributor)Costsforrepair,standardcalibration,andcalibrationtraceabletoN.I.S.T.areavailable.NOTE: You must obtain a CSA# before returning any instrument.

Technical and Sales AssistanceIf you are experiencing any technical problems, or require any assistancewiththeproperoperationorapplicationofyourinstrument,pleasecall,faxore-mailourtechnicalsupportteam:

ChauvinArnoux®,Inc.d.b.a. AEMC®Instruments Phone: (800) 945-2362 (Ext. 351)

(603) 749-6434 (Ext. 351) Fax: (603) 742-2346 [email protected]

Page 13: THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846

Thermo-Hygrometer Model CA846 11

Limited WarrantyTheModelCA846iswarrantedtotheownerforaperiodof2yearsfromthedateoforiginalpurchaseagainstdefectsinmanufacture.Thislimitedwarrantyis given by AEMC® Instruments, not by the distributor from whom it waspurchased.Thiswarrantyisvoidiftheunithasbeentamperedwith,abusedorifthedefectisrelatedtoservicenotperformedbyAEMC® Instruments.

For full and detailed warranty coverage, please read the Warranty Cov-erage Information, which is attached to the Warranty Registration Card (if enclosed) or is available at www.aemc.com. Please keep the War-ranty Coverage Information with your records.

What AEMC® Instruments will do:If a malfunction occurs within the warranty period, you may return theinstrument to us for repair, provided we have your warranty registrationinformation on file or a proof of purchase.AEMC® Instruments will, at itsoption,repairorreplacethefaultymaterial.

REGISTER ONLINE AT:www.aemc.com

Warranty RepairsWhat you must do to return an Instrument for Warranty Repair: First, requestaCustomerServiceAuthorizationNumber (CSA#)byphoneorbyfaxfromourServiceDepartment(seeaddressbelow),thenreturntheinstrumentalongwiththesignedCSAForm.PleasewritetheCSA#ontheoutsideoftheshippingcontainer.Returntheinstrument,postageorshipmentpre-paidto:

ChauvinArnoux®,Inc.d.b.a.AEMC®InstrumentsServiceDepartment15FaradayDrive•Dover,NH03820USATel: (800) 945-2362 (Ext. 360)

(603) 749-6434 (Ext. 360)Fax: (603) 742-2346 or (603) [email protected]

Caution:Toprotectyourselfagainstin-transitloss,werecommendyouinsureyourreturnedmaterial.

NOTE: You must obtain a CSA# before returning any instrument.

Page 14: THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846

12 Thermo-Hygrometer Model CA846

NOTES:

Page 15: THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846

Termo-Higrómetro Modelo CA846 13

Table of Contents

1. INTRODUCCIÓN ............................................................................. 141.1 Símbolos Eléctricos Internacionales .......................................141.2 DefinicióndelasCategoríasdeMedición ..............................151.3 RecepcióndeSuEmbarque ...................................................151.4 InformaciónparaponerunaOrden .........................................15

2. CARACTERÍSTICAS DEL PRODUCTO .............................................. 162.1 Descripción .............................................................................162.2 Botones ...................................................................................17

2.2.1 SelectordeFuncionesCentral(Amarillo) ...................17

2.2.2 Botóndeluzposterior y ºC/ºF ..............................172.2.3 BotónMAX ..................................................................172.2.4 BotónHOLD ...............................................................17

3. ESPECIFICACIONES ...................................................................... 183.1 EspecificacionesAmbientales ................................................183.2 EspecificacionesdeMecanicas ..............................................193.3 EspecificacionesdeSeguridad ...............................................19

4. OPERACIÓN .................................................................................. 204.1 Recomendaciones ..................................................................204.2 Operación ...............................................................................20

5. MANTENIMIENTO ......................................................................... 215.1 ReemplazodelaBatería ........................................................215.2 Limpieza .................................................................................21

ReparaciónyCalibración ......................................................................22Asistencia Técnica y de Ventas .............................................................22Garantía Limitada ..................................................................................23ReparacionesbajoGarantía..................................................................23

Page 16: THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846

14 Termo-Higrómetro Modelo CA846

CAPÍTULO 1

INTRODUCCIÓN

Advertencia

• No conectar ni tocar ningún circuito eléctrico con enTermo-Higrómetro.

• Paraevitarheridasoriesgodeincendio,noopereesteproductoenatmósferasoambientesexplosivos.

• CuandouseelTermo-Higrómetroremueva(destornille)eltubometálicoprotectorquecubrelacabezasensora.

• NosumerjalacabezasensoradelTermo-Higrómetroenlíquidos– estopuededañarpermanentementelossensores.

• RepongaeltubometálicoprotectorquecubrelacabezasensoracuandonoestéusandoelTermo-Higrómetro.

1.1 Símbolos Eléctricos Internacionales

Este símbolo significas que el instrumento esta protegido con doble aislamiento.Este símbolo en el instrumento indica una ADVERTENCIA y que el operador deberá consultar el manual del usuario para obtener instrucciones antes de utilizar el instrumento. En este manual, el símbolo anterior a las instrucciones indica que si las instrucciones no se siguen, se pueden provocar, lesión corporal y también se pueden provocar daños en los productos¡Peligro! Riesgo de shock eléctrico. La tensión en la parte marcada con este símbolo puede ser peligroso

De conformidad con WEEE 2002/96/EC

Page 17: THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846

Termo-Higrómetro Modelo CA846 15

1.2 Definición de las Categorías de Medición

Cat. II:Paralasmedicionesrealizadasenloscircuitosconectadodirecta-mentealsistemadedistribucióneléctrica.Ejemplosdeellosonlasmedicionesdelosaparatosdomésticosoinstrumentosportátiles.

Cat. III:Para lasmediciones realizadas en la construcción de la insta-laciónaniveldedistribución, talescomo laconfiguraciónenunequipodeinstalaciónfijaydisyuntores

Cat. IV:Paralasmedicionesrealizadasenelprincipalsuministroeléctrico(<1000),comoenlosdispositivosdeproteccióndesobrecorrienteprimaria,unidadesdecontroldeondulación,omedidores.

1.3 Recepción de Su EmbarqueLuegoderecibidosuembarque,asegúresequeelcontenidocoincideconlaguíadedespacho.Aviseasudistribuidorsobrecualquierpartefaltante.Si el equipo aparece dañado, presente un reclamo inmediatamente altransportadoryavise inmediatamenteasudistribuidor,dandounades-cripcióndetalladadelosdaños.Conserveelempaquedañadoparares-paldarsureclamo.Noutiliceuninstrumentoqueaparezcadañado.

1.4 Información para poner una OrdenTermo-Higrómetro Modelo CA846 ...................................Cat. #2121.24Incluye una batería Alcalina de 9V, un protector gris rugoso a pruebas de golpes y resistente al polvo y manual del usuario

Page 18: THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846

16 Termo-Higrómetro Modelo CA846

CAPÍTULO 2

CARACTERÍSTICAS DEL PRODUCTO

2.1 DescripciónEl Modelo CA846 de AEMC®esunTermo-Higrómetrodigitalportátil,com-pactoyfácildeusardiseñadoparaoperarloconunasolamano.UtilizaunsensorNTCyunsensordehumedadcapacitivoformadoporunapelículadelgadadepolímero.

ElTermo-Higrómetroseentregaconelsensoryunafundaprotectoradegoma.ElModeloCA846poseetambiénunapantalladeLCDconilumi-naciónposterior,unafunciónmantenerlectura(HOLD),yunafunciónderegistro de máximos (MAX).

1. SensorTemperatura/Humedadycubiertaprotectoradelsensor

2. Pantalla de 3½ digitos

3. BotónMAX(Máximo)

4. Selector°C/°FyLuzPosterior

5. BotónHOLD(Guardar)

6. Selector Encendido/Modo(Temp.-RH)

1

2

3 5

64

Page 19: THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846

Termo-Higrómetro Modelo CA846 17

2.2 Botones

2.2.1 Selector de Funciones Central (Amarillo)

DesliceelbotóncentralparaencenderelTermo-Higrómetroyseleccionelaposición%HRoºC/ºF.DesliceelbotónhaciaOFFdespuésdeusarlo.

2.2.2 Botón de luz posterior y ºC/ºF

• Presioneelbotón paraencenderlailuminaciónposterior.

• Presione el botón nuevamente para apagar la iluminación poste-rior.

• Presioneelbotón durante2segundosparacambiarlaescaladetemperaturaaºCoºF.LaescaladetemperaturaºCoºFsemuestraenlaesquinainferiorderechadelapantalla.

2.2.3 Botón MAX

• PresioneelbotónMAXparaentrarenelmodoMAX.Elsímbolo“MAX”apareceenlaesquinasuperiorderechadelapantalla.

• Laescalaseleccionada(%HRoºC/ºF)registrayactualizalosvaloresmáximosabsolutos.

• PresioneelbotónMAXnuevamenteparasalirdelmodode registroMAX(elsímbolo“MAX”desaparece).

• ElbotónHOLD(veaabajo)puedeserusadoenelmodoMAXpara“congelar”(noseactualizamás)lalecturaMAXenlapantalla.

2.2.4 Botón HOLD

El botón HOLD “congela” la lectura en la pantalla. Presione el botón“HOLD”alternadamenteparaactivar/desactivar la funciónHOLD.EnelmodoHOLD,elsímbolo“HOLD”apareceenlapartesuperiordelapanta-llaLCDysemuestralaúltimalecturahastaquesedesactiveestemodo.

Page 20: THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846

18 Termo-Higrómetro Modelo CA846

CAPÍTULO 3

ESPECIFICACIONES

3.1 Especificaciones AmbientalesEscala de Temperatura:Celsius(°C)oFahrenheit(°F)aeleccióndelusuario

Sensor de Temperatura: NTC

Rango de Medición:-4°a140°F,-20°a60°C

Resolución: 0.1°F/°C

Exactitud: 32° a 140°F: ±1°F-4° a 32°F: ±2°F 0° a 60°C: ±0.5°C-20° a 0°C: ±1°C

Coeficiente de Temperatura:0.1veceslaexactitudaplicablepor°Cde0°a18°Cy28°a50°C(32°a64°F y 82° a 122°F)

Sensor de Humedad:Sensor electrónico capacitivo basado en una película de polímero. (Elsensornoesafectadoporcondensacióndeaguayes inmunea lamayoríadelosvaporesdereactivos)

Rango de Medición: 0% a 100%HR

Resolución: 0.1%HR

Exactitud (@ 25°C): 10%-90% HR; ± 5.0%0%-10% HR; 90% a 100% HR; ± 10.0%

Tiempo de Respuesta del Sensor para 90% del Rango:Valortípico60s

Estabilidad del Sensor:±2%HR,valortípico2años

Histéresis del Sensor (10% a 90% a 10% HR):valortípico±1%HR

Dependencia de la temperatura del Sensor:Despreciablede32°a140°F(0°a60°C)

Page 21: THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846

Termo-Higrómetro Modelo CA846 19

Temperatura de Operación: 32° a 122°F (0° a 50°C) a < 80%HR

Temperatura de Almacenaje:-4°a140°F(-20°a60°C),0a80%HRsinbatería

Exactitud:Exactitudestablecidaa23°C±5°C,<90%HR

Altitud: 2000m máx

Protección de Entrada:Voltajedeentradamáximoencualquierentrada24VCDo24Vrms

3.2 Especificaciones de MecanicasPantalla: Pantalla de cristal líquido (LCD) con dígitos de 3½ y lecturamáxima de 1999

Sobre-Rango:semuestraelsímbolo“OL”

Indicación de Batería Baja:Semuestraelsímbolo cuandoelvoltajede labateríacaebajoelvalorrequerido.

Velocidad de Muestreo:nominal, 2.5vecesporsegundo.

Batería:BateríaEstándarde9V(NEDA1604,IEC6F22006P,oequiva-lente)

Duración de la Batería:Valortípico200horasconbateríadecinc-car-bón

Dimensiones: 6.81 x 2.38 x 1.5 (173 x 60.5 x 38mm)

Peso:Aprox7oz(197g)incluyendobatería

3.3 Especificaciones de Seguridad

EN61010-1(1995-A2),ProtecciónClaseIII

CategoríadeSobrevoltaje(CATIII,24V),ContaminaciónGrado2

Uso Interior

Page 22: THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846

20 Termo-Higrómetro Modelo CA846

CAPÍTULO 4

OPERACIÓN

4.1 Recomendaciones• Paratenermedicionesconfiables,dejequelaslecturasseestabilicen.

Elsensordehumedadyeldetemperaturadebenalcanzarunequili-brio con el medio a medir.

• Evite loserroresen lamediciónde temperatura inducidospor tiem-posdemediciónmuycortos,luzdelsolincidentedurantelamedición,calefacción,murosexternosfríos,corrientesdeaire(Ej.ventiladores),fuentesradiantesinclusivelamanoy/ocalorcorporal,etc.

• Eviteerroresenlamedicióndehumedadinducidosporvapor,salpica-durasdeagua,goterasdeaguaocondensaciónsobreelsensor,etc.

• Evitelacontaminacióndelsensorinducidaporpartículasenelaireomediciones en sustancias polvorientas. La contaminación se puedeevitarefectuandolasmedicionesatravésdeunfiltro(proporcionadoporelusuario).Elfiltrodebeser limpiadoo reemplazadoperiódica-mente,dependiendodelgradodecontaminaciónenelsitiodemedi-ción.

4.2 Operación1. Remuevaeltubometálicoprotectorquecubreelsensor,destornillán-

dolo.

2. Coloqueelinterruptordeencendidoenelrangodeseado%HRoºC/ºF.

3. Dejequela(s)lectura(s)seestabilice(n).El%HRtomaalmenos60segundosenalcanzar90%.

4. Lealapantalla.

5. Despuésdeusarlo,repongaeltubometálicoprotectorquecubreelsensor,atornillándolo.

6. Apagueelinstrumentocuandohayaterminado

Page 23: THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846

Termo-Higrómetro Modelo CA846 21

CAPÍTULO 5

MANTENIMIENTO

Utilicesólorepuestosdefábricaparalamanutención.Elfabricantenosehaceresponsableporaccidentes,incidentes,omalfuncionamientopos-terioresaunareparaciónefectuadaporotrosquenoseansuCentrodeServiciouotrocentrodeservicioautorizado.

5.1 Reemplazo de la BateríaLaenergíaesproporcionadaporunabateríaestándarde9voltios.(NEDA1604,IEC6F22).El símbolo apareceen lapantallaLCDcuandohayque reempla-zarla.

Para reemplazar la batería:• ApagueelHigrómetro.• Remuevalafundadegoma.• Remueva el tornillo en la parte posterior del medidor y levante la

cubiertadelabatería.• Reemplacelabateríayrepongalacubiertaylafunda.

5.2 Limpieza• Periódicamente limpie lacajaconunpañohúmedoyundetergente

suave,siserequiere.• Noutiliceabrasivosnisolventes.• Nopermitaqueentrelíquidoalacajaoalazonadelsensor.

Page 24: THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846

22 Termo-Higrómetro Modelo CA846

Reparación y CalibraciónParaasegurarquesuinstrumentocumpleconlasespecificacionesdefábrica,recomendamosqueloenvíeanuestroCentrodeServicioparare-calibración,anualmenteosegúnlorequieranotrosestándaresoprocedimientosinternos.

Para reparación y calibración del instrumento:DebecontactarnuestroCentrodeServicioparasolicitarunNúmerodeAuto-rizacióndeServicioalCliente(CSA#).Estoaseguraráquecuandollegue,elinstrumentoserá ingresadoyprocesadoconprontitud.Por favorescribaelCSA#enelexteriordelenvase.

ChauvinArnoux®,Inc.d.b.a. AEMC®Instruments15 Faraday DriveDover,NH03820USATel: (800) 945-2362 (Ext. 360)

(603) 749-6434 (Ext. 360)Fax: (603) 742-2346 or (603) [email protected]

(Ocontactesudistribuidorautorizado)Loscostosdereparaciónycalibraciónestándarestándisponibles.NOTA: Todos los clientes deben obtener un a CSA# antes de enviar cualquier instrumento.

Asistencia Técnica y de VentasSitienecualquierproblematécnicoonecesitaayudaparalacorrectaopera-ciónoaplicacióndesuinstrumentoporfavorllame,envíeunfaxoe-mailanuestrosoportetécnico:

ChauvinArnoux®,Inc.d.b.a. AEMC®Instruments Phone: (800) 945-2361 (Ext. 351)

(603) 749-6434 (Ext. 351) Fax: (603) 742-2346 [email protected]

Page 25: THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846

Termo-Higrómetro Modelo CA846 23

Garantía LimitadaEl Termo-Higrómetro Modelo CA846 es garantizados al propietario pordefectosdefabricación,porunperíodode2añosdesdelafechaoriginaldecompra.Estagarantía limitadaesdadaporAEMC® Instruments,noporeldistribuidoraquiensecompróelinstrumento.Estagarantíaquedaviciadasilaunidadhasidointervenida,abusadaosilafallaserelacionaconunservicionorealizadoporAEMC®Instruments.

Para detalles y una descripción completa de la cobertura de la garantía, por favor lea la Tarjeta de Cobertura de Garantía, que se adjunta a la Tar-jeta de Registro de Garantía. Por favor conserve la Tarjeta de Cobertura de Garantía con sus registros.

Lo que AEMC® Instruments hará:Siocurreunafalladefuncionamientodentrode2años,ustedpuededevol-vernoselinstrumentoparasureparaciónsincargo,siempreycuandotenga-mossuTARJETADEREGISTROarchivada.AEMC®Instrumentsrepararáoreemplazaráelmaterialdefectuosos,asudiscreción.Sinotenemosarchivadasutarjetaderegistro,lepediremosuncomprobantede compra fechado, como también su TARJETADE REGISTRO junto almaterialdefectuoso.

Registro En línea en: www.aemc.com

Reparaciones bajo GarantíaLo que Usted debe hacer para enviar un Instrumento para Reparación bajo Garantía: Primero, solicite unNúmerodeAutorización deServicio alCliente (CSA#)porteléfonooporfaxanuestroDepartamentodeServicio(vealadirecciónabajo), luegoenvíeel instrumentojuntoconelformularioCSAfirmado.PorfavorescribaelCSA#enelexteriordelenvase.Envíeelinstrumentoconelfranqueoofleteprepagadoa:

ChauvinArnoux®,Inc.d.b.a.AEMC®InstrumentsServiceDepartment15FaradayDrive•Dover,NH03820USATel: (800) 945-2362 (Ext. 360)

(603) 749-6434 (Ext. 360)Fax: (603) 742-2346 or (603) [email protected]

Precaución:Paraprotegersecontrapérdidasentránsito,lerecomendamosasegurarsumercadería.NOTA: Todos los clientes deben obtener un CSA# antes de enviar un instrument.

Page 26: THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846

24 Termo-Higrómetro Modelo CA846

NOTAS:

Page 27: THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846
Page 28: THERMO-HYGROMETER CA846 TERMO-HIGRÓMETRO · THERMO-HYGROMETER TERMO-HIGRÓMETRO ENGLISH User Manual ESPAÑOL Manual de Instrucciones CA846

03/18

99-MAN 100240 v7

Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments15FaradayDrive•Dover,NH03820USA•Phone:(603)749-6434•Fax:(603)742-2346

www.aemc.com