THERMAL INSULATION - · PDF file2 UNI Associazione Italiana Polistirene Espanso G Ü T E S...
Transcript of THERMAL INSULATION - · PDF file2 UNI Associazione Italiana Polistirene Espanso G Ü T E S...
1
REV. 04
THERMAL INSULATION
2
UNIAssociazione Italiana Polistirene Espanso
GÜTE S C HUTZ
•
• HA
R T S C H A UM•
RAL
GSH
THE PRODUCTION OF THERMAL, ACOUSTIC INSULATION, WATERPROOF SYSTEMS AND OTHER BUILDING COMPONENTS
Isosystem is a dynamic company which produces thermal, acoustic, venti-
lated and waterproof insulating couplings in addition to other building com-
ponents. A large company with vast stock which ensures the logistics sys-
tem provides clients with effective solutions in short timeframes. Isosystem
develops training projects for companies governing the use and the instal-
lation of insulating systems in addition to a post-sales support service.
Member of
Eco-sustainability represents the primary objective for buildings: bio-housing, bio-ar-
chitecture, green energy and green building are essential in terms of eco-sustainability
making Isosystem, the ideal partner. At present, before selecting an area on which to
build, an environmental assessment of the existing relationship between home and sur-
rounding environment must be carried out, where an evaluation of the climate of the
location, the affecting winds, the geometric characteristics of the land, exposure to the
sun is carried out. As well as an exclusively technical focus, at present more than ever,
the only safe, real investment over time, is the home. Your home is the essential base on
which to build a family.
We are always in harmony
with the environment!!
ECO-SUSTAINABILITYGREEN BUILdING
4
At present, reducing energy consumption does not sim-ply involve saving a significant amount of energy, but also includes significantly protecting the environment. The air-conditioning and heating of buildings relies on a large percentage of energy; by simply improving efficiency, a re-duction of up to 40% of harmful emissions can be achieved. Isosystem manufactured waterproof, ventilated thermal in-sulation and structural thermal insulation systems, thanks to their appropriateness and features guarantee excel-lent thermal insulation allowing for increased well-being, enabling significant energy saving reducing raw material consumption and, consequently harmful emissions, primar-ily CO2, the main cause behind the greenhouse effect and climatic variations.
TERRAETHERMAL INSULATION
THERMAL INSULATION
AdVANTAGES
ENERGY SAVING
EASY INSTALLATION
SIGNIFICANT INSTALLATION COST SAVINGS
USEFUL IN RENOVATIONSLARGE RANGE OF DESIGNS FOR ALL REQUIREMENTS
DESIGN ASSISTANCE
5
From Ministerial Decree of the 11 March 2008. Financing Legislation 2008Thermal transmittance limits for the application of tax deductions for the
energy performance of buildings.
The table below makes reference to Legislative Decree no. 311 of the 29 December 2006, "Corrective requirements and those included as part of Legislative Decree no. 192 of the 19 August 2005, relative to the implementation of Directive 2002/91/EC governing the energy
performance of buildings".
Limits values as specified by legislation in force
Table 1 useful thermal transmittance limit values U of the building shell structures expressed in W/m 2K
Climatic area Vertical opaque structuresHorizontal or inclined opaque structures
Roofs Floors*
A 0.62 0.38 0.65
B 0.48 0.38 0.49
C 0.40 0.38 0.42
D 0.36 0.32 0.36
E 0.34 0.30 0.33
F 0.33 0.29 0.32
(*) Flooring in non-heated or external areas
The table below refers to Legislative Decree of the 26 January 2010, an update of Legislative Decree of the 11 March 2008, the implementation of Section 1, Paragraph 24, of Legislation
no. 244 of the 24 December 2007, which defines the limit values of annual primary energy and thermal transmittance requirements according to Paragraphs 344 and 345 of Paragraph 1 of
Legislation no. 296 of the 27 December 2006.
Values specified for 2010, for a 50% deduction relative to building energy requalification.
Table 1 useful thermal transmittance limit values U of the building shell structures expressed in W/m 2K
Climatic area Vertical opaque structuresHorizontal or inclined opaque structures
Roofs Floors*
A 0.62 0.54 0.60
B 0.48 0.41 0.46
C 0.40 0.34 0.40
D 0.36 0.29 0.34
E 0.34 0.27 0.30
F 0.33 0.26 0.28
(*) Flooring in non-heated or external areas
EXTERNAL TERMAL INSULATION COMPOSITE SYSTEM
Description Class U.M. EPS 80 EPS 100 EPS 120 EPS 150 EPS 200 Standard
TECHNICAL CHARACTERISTICS IN COMPLIANCE WITH STANDARD UNI EN 13163EPS SLABS FOR EXTERNAL THERMAL INSULATION COMPOSITE SYSTEMS
DIMENSIONS: Width 500-1000 mm Thickness from 10 to 1000 mmThe information forming part of the present specifications is based upon current knowledge and is only provided as examples. It is not legally binding and may be modified at any moment without prior warning.
Tolerance across length L2 mm ±2 ±2 ±2 ±2 ±2 EN 822
Tolerance across width W2 mm ±2 ±2 ±2 ±2 ±2 EN 822
Tolerance across thickness T2 mm ±1 ±1 ±1 ±1 ±1 EN 823
Tolerance across perpendicularity S2 mm/m ≤2 ≤2 ≤2 ≤2 ≤2 EN 824
Tolerance across planarity P4 mm ±5 ±5 ±5 ±5 ±5 EN 825
Bending strength BS kPa �125 �150 �170 �200 �250 EN 12089
Compression resistance at
10% crushing CS(10) kPa �80 �100 �120 �150 �200 EN 826
Thermal conductivity λD 0.038 0.036 0.035 0.034 0.034 EN 12939
Fire performance Class E E E E E EN 13501/1
Tensile strength TR kPa �150 �150 �150 EN 1607
Capacity temperature limit °C 75 75 75 75 75
Water absorption % WL(T) ≤ 3 ≤ 3 ≤ 3 ≤ 2 ≤ 2 EN 12087
Water vapour transmission MU 20-40 40-60 60-80 70-90 90-120 EN 12086
7
EXTERNAL TERMAL INSULATION COMPOSITE SYSTEM
Description Class U.M. EPS 70 EPS 100 Standard
DIMENSIONS: Width 500-1000 mm Thickness from 10 to 1000 mmThe information forming part of the present specifications is based upon current knowledge and is only provided as examples. It is not legally binding and may be modified at any moment without prior warning.
Tolerance across length L2 mm ±2 ±2 EN 822
Tolerance across width W2 mm ±2 ±2 EN 822
Tolerance across thickness T2 mm ±2 ±2 EN 823
Tolerance across perpendicularity S2 mm/m ≤2 ≤2 EN 824
Tolerance across planarity P4 mm/m ±5 ±5 EN 825
Bending strength BS kPa �115 �150 EN 12089
Compression resistance at
10% crushing CS(10) kPa �70 �100 EN 826
Thermal conductivity λD 0.032 0.031 EN 12939
Fire performance Class E E EN 13501/1
Tensile strength TR kPa �150 �150 EN 1607
Capacity temperature limit °C 75 75
Water absorption % WL(T) ≤ 3 ≤ 3 EN 12087
Water vapour transmission MU 20-40 40-60 EN 12086
TECHNICAL CHARACTERISTICS IN COMPLIANCE WITH STANDARD UNI EN 13163EPS SLABS WITH GRAPHITE ADDITIVE FOR EXTERNAL THERMAL INSULATION COMPOSITE SYSTEMS
XLL
Description Class U.M. EPS 150 Standard
THERMAL RESISTANCE “R”= 3.33Mqk/WTHERMAL TRANSMITTANCE “U”= 0.30 W/Mqk
THERMAL RESISTANCE “R”= 2.77Mqk/WTHERMAL TRANSMITTANCE “U”= 0.36 W/Mqk
The information forming part of the present specifications is based upon current knowledge and is only provided as examples. It is not legally binding and may be modified at any moment without prior warning.
Tolerance across length L2 mm ±2 EN 822
Tolerance across width W2 mm ±2 EN 822
Tolerance across thickness T2 mm ±2 EN 823
Tolerance across perpendicularity S2 mm/m ≤2 EN 824
Tolerance across planarity P4 mm/m ±5 EN 825
Bending strength BS kPa �200 EN 12089
Compression resistance at
10% crushing CS(10) kPa �150 EN 826
Thermal conductivity λD 0,030 EN 12939
Fire performance Class E EN 13501/1
Capacity temperature limit °C 75
Water absorption % WL(T) ≤ 3 EN 12087
Water vapour transmission MU 30-70 EN 12086
HIGH DENSITY EPS SLAB WITH GRAPHITE ADDITIVE FOR THERMAL CAVITY AND FLOORING INSULATION
TERMOPOR XL/L AT EQUAL THICKNESS PROVIDES BETTER PERFORMANCE
EXTRUDED XPS
th. 10 cm
th. 10 cm
TERMOPOR XL/L
λD 0.036
λD 0.030
9
TERMOPOR XL DIMENSIONS: Width 600 mmLength 2800 mm Thickness from 30 to 200 mm
TERMOPOR L DIMENSIONS: Width 600 mmLength 1200 mm Thickness from 30 to 200 mm
λ D 0
.030
λ D 0
.030
RABBETED
RABBETED M/F
1
2
1
2
10
ISOVENT®/ISOVENT 5000
1 2 3
ISOVENT/ISOVENT 5000, system created to air-heat roofs made by coupling three panels made from waste materials from the first time the wood is used (EUROSTRAND OSB or plywood with phenolic joints) and insulation materials specifically shaped to guarantee air flow.
1 ISOVENT-EPS/ISOVENT-EPS 5000 EUROSTRAND OSB 12 mm panel, EPS insulating sheet in compliance with Standard UNI EN 13163 EC, shaped with ventilation channels.ISOVENT EPS dimensions 2440x1220 mm = 2.98 m2 rabbeted on short sides.ISOVENT 5000 EPS dimensions 5000x585 mm = 2.925 m2 rabbeted on long sides.
2 ISOVENT-GRAFITE/ISOVENT-GRAFITE 5000EUROSTRAND OSB 12 mm panel, EPS insulating sheet with GRAPHITE in compliance with Standard UNI EN 13163 EC, shaped with ventilation channels.ISOVENT GRAFITE dimensions 2440x1220 mm = 2.98 m2 rabbeted on short sides.ISOVENT 5000 GRAFITE dimensions 5000x585 mm = 2.925 m2 rabbeted on long sides.
3 ISOVENT-ESTEUROSTRAND OSB 12 mm panel, XPS insulating sheet in compliance with Standard UNI EN 13163 EC, shaped with ventilation channels. ISOVENT-EST dimensions 2440x585 mm = 1.427 m2, rabbeted on long sides
Variations upon request: thickness of the OSB on the upper part - panel dimensions.
ADVANTAGES - Laying of the ISOVENT/ISOVENT 5000 system is practical, rapid and simple. - Large size roofs can be caulked in short timeframes. - The ISOVENT/ISOVENT 5000 system is a safe and treadable support. - Individual ventilation channels enable effective ventilation (chimney effect). - The ISOVENT/ISOVENT 5000 system provides hassle-free waterproofing.
11
1 ISOVENT COMPOSITO (EPS/EPS GRAPHITE) AND WOOD FIBRE System created to air-heat roofs, made up of two layers of insulating material, each with different properties: sintered expanded polystyrene or with graphite additive in compliance with Standard EC 13163 and wood fibre in compliance with Standard EC 13171 coupled with a EUROSTRAND OSB panel in compliance with Standard EN 300 to guarantee the best: thermal insulation, thermal inertia and sound insulation.Dimensions: 1200x1350 mm
2 ISOVENT COMPOSITO (EPS/EPS GRAPHITE) AND ROCKWOOLSystem created to air-heat roofs, made up of two layers of insulating material, each with different properties: sintered expanded polystyrene or with graphite additive in compliance with Standard EC 13163 and rockwool in compliance with Standard EC 13171 coupled with a EUROSTRAND OSB panel in compliance with Standard EN 300 to guarantee the best: thermal insulation, thermal inertia and sound insulation.Dimensions: 1000x1200 mm
Variations upon request: thickness of the OSB on the upper part - panel dimensions
ADVANTAGES - Laying of the ISOVENT COMPOSITO system is practical, rapid and simple. - Large size roofs can be caulked in short timeframes. - The ISOVENT COMPOSITO system is a safe and treadable support. - Individual ventilation channels enable effective ventilation (chimney effect). - The ISOVENT COMPOSITO system provides hassle-free waterproofing. - The use of the ISOVENT COMPOSITO system in roofs guarantees living comfort in the underlying
body of the building, it provides thermal and sound insulation, energy saving, resistance to water vapour and excellent ventilation, ideal for wood roofs.
1 1 2 2
ISOVENT® COMPOSITO
GREEN BUILdING
12
ISOVENT TOP®/ISOVENT TOP 5000
1 ISOVENT-TOP EPS/ISOVENT-TOP EPS 5000System created to air-heat roofs, made up of a EUROSTRAND OSB 12 mm thick panel, EPS insulating sheet in compliance with Standard UNI EN 13163 EC, shaped with ventilation channels. The bottom part is available in smooth or stave plywood panels with thickness of 9 mm, a three-layer fir panel with thickness of 14 mm, a single-layer fir panel with thickness of 10 mm, plasterboard sheet (standard, waterproof or fireproof) or 12 mm plaster fibre (see pg. 24) or OSB,ISOVENT-TOP EPS dimensions 2440x1220 mm = 2.92 m2 rabbeted on sides.ISOVENT 5000 EPS dimensions 5000x585 mm = 2.925 m2 rabbeted on long sides.
2 ISOVENT-TOP GRAFITE/ISOVENT-TOP GRAFITE 5000System created to air-heat roofs, made up of a EUROSTRAND OSB 12 mm thick panel, EPS insulating sheet with GRAPHITE in compliance with Standard UNI EN 13163 EC, shaped with ventilation channels. The bottom part is available in smooth or stave plywood panels with thickness of 9 mm, a three-layer fir panel with thickness of 14 mm, a single-layer fir panel with thickness of 10 mm, plasterboard sheet (standard, waterproof or fireproof) or 12 mm plaster fibre (see pg. 24) or OSB,ISOVENT-TOP EPS GRAFITE dimensions 2440x1220 mm = 2.92 m2 rabbeted on sides.ISOVENT-TOP 5000 EPS GRAFITE dimensions 5000x585 = 2.925 m2 rabbeted on long sides.
ADVANTAGES - The ISOVENT-TOP/ISOVENT TOP 5000 system is a composite, structural panel, rabbeted on 2 sides
with the bottom part on display. - The ISOVENT-TOP/ISOVENT TOP 5000 system enables the creation of a safe and treadable
insulation set. - The primary framework on which the ISOVENT-TOP/ISOVENT TOP 5000 system is laid, can be made
from metal or solid wood. The system is attached using dedicated mechanical systems. Variations upon request: thickness of the OSB on the upper part - panel dimensions.
1 2
13
1 ISOVENT TOP COMPOSITO/5000 (EPS/EPS GRAPHITE) AND WOOD FIBRE System created to air-heat roofs, made up of two layers of insulating material, each with different properties: sintered expanded polystyrene or with graphite additive in compliance with Standard EC 13163 and wood fibre in compliance with Standard EC 13171 coupled with a EUROSTRAND OSB panel in compliance with Standard EN 300, whilst the bottom part is available in smooth or stave plywood panels with thickness of 9 mm, a three-layer fir panel with thickness of 14 mm, a single-layer fir panel with thickness of 10 mm, plasterboard sheet (standard, waterproof or fireproof) or 12 mm plaster fibre (see pg. 24) or OSB.The system guarantees the best performance in terms of: thermal insulation, thermal inertia and sound insulation.ISOVENT TOP COMPOSITO dimensions: 1200x2440 mm = 2.928 m2 rabbeted on sides.ISOVENT TOP COMPOSITO 5000 dimensions: 5000x585 mm = 2.925 m2 rabbeted on long sides.
2 ISOVENT TOP COMPOSITO/5000 (EPS/EPS GRAPHITE) AND ROCKWOOLSystem created to air-heat roofs, made up of two layers of insulating material, each with different properties: sintered expanded polystyrene or with graphite additive in compliance with Standard EC 13163 and wood fibre in compliance with Standard EC 13171 coupled with a EUROSTRAND OSB panel in compliance with Standard EN 300, whilst the bottom part is available in smooth or stave plywood panels with thickness of 9 mm, a three-layer fir panel with thickness of 14 mm, a single-layer fir panel with thickness of 10 mm, plasterboard sheet (standard, waterproof or fireproof) or 12 mm plaster fibre (see pg. 24) or OSB. The system guarantees the best performance in terms of: thermal insulation, thermal inertia and sound insulation.ISOVENT TOP COMPOSITO dimensions: 1200x2440 mm = 2.928 m2 rabbeted on sides.ISOVENT TOP COMPOSITO 5000 dimensions: 5000x585 mm = 2.925 m2 rabbeted on long sides.
Variations upon request: thickness of the OSB on the upper part - panel dimensions
ADVANTAGES - Laying of the ISOVENT TOP COMPOSITO system is practical, rapid and simple. - Large size roofs can be caulked in short timeframes. - The ISOVENT TOP COMPOSITO system is a safe and treadable support. - Individual ventilation channels enable effective ventilation (chimney effect). - The ISOVENT TOP COMPOSITO system provides hassle-free waterproofing. - The use of the ISOVENT TOP COMPOSITO system in roofs guarantees living comfort in the underlying
body of the building, it provides thermal and sound insulation, energy saving, resistance to water vapour and excellent ventilation.
11 22
ISOVENT TOP® COMPOSITO
GREEN BUILdING
14
ISOVENT TERMO ACUSTIC®
ISOVENT TERMO ACUSTIC Sheathing acoustic panel for roofs made from bisoluble EC branded rockwool in conformity with UNI EN 13162:2001, obtained from the fusion and spinning of natural rocks with density equal to 160 kg/mc. It boats high resistance to compression, it naturally has good thermal characteristics and excellent sound proofing characteristics. Resistance to chemical agents and resistance to ageing is guaranteed. A double layer heat-sealed sheet with external nebulized aluminium is applied to ventilation channels to ensure an exceptionally high heat reflectivity coefficient. Everything is combined with a EUROSTRAND OSB panel.Panel dimensions: 1200x1000 RABBETEDStandard thicknesses available: (50+50+15) - (80+50+15) - (100+50+15) - (120+50+15) mmOSB thickness: 15 mm
TECHNICAL INFORMATION according to UNI EN 13162:2001FIRE PERFORMANCE ACCORDING TO EN 13501: Euroclass A1THERMAL CONDUCTIVITY: =0.039W/mKTHERMAL RESISTANCE: average thickness 50 mm RD = 1.28 m2 K/W average thickness 80 mm RD = 2.05 m2 K/Waverage thickness 100 mm RD = 2.56 m2 K/Waverage thickness 120 mm RD = 3.08 m2 K/W
SPECIFIC HEAT: Cp = 1030 J/KgKPRODUCT MELTING POINT: 1000 °CWATER VAPOUR DIFFUSION RESISTANCE: µ = 1.3 - 1.4
Roof sound proofing result with ISOVENT TERMO ACUSTIC.Results of tests carried out at building yard:
dls,2m,nT,w=41dB
B R E V E T TATO
SIS
TEM
A ISOVENT TERMO ACUSTIC
NS. RIF.:M519988
GREEN BUILdING
15
ISOVENT BIO SUGHEROVentilated thermal system made up of a cork panel specifically shaped with rectangular section ventilation channels paired with a EUROSTRAND OSB panel according to Standard EN 300.
Panel dimensions: Length 1000 mm - Width 1000 mm - 1.00 m2
Standard thicknesses available: (40+40+12) - (50+40+12) - (50+50+12) - (60+40+12) - (60+50+12) mmAdditional thicknesses upon request.OSB thickness: 12 mm
SOUND PROOFING:
dB=20-35 (500 Hz)** dependent on thickness
ISOVENT BIO SUGHERO®
GREEN BUILdING
16
ISOVENT 0023Ventilated thermal system made up of a rigid polyiso foam panel according to Standard UNI EN 13165 specifically shaped with rectangular section ventilation channels paired with panels made from waste materials from the first time the wood is used, EUROSTRAND OSB UNI EN 300. The use of the ISOVENT 0023 system, with its excellent thermal conductivity λD = 0.023 (stated lambda), in building roofs, guarantees living comfort, thermal insulation, energy saving, resistance to water vapour and excellent ventilation.Standard panel dimensions: 1200x1000 mm = 1.2 m2
Standard thicknesses available: (40+40+12) - (50+40+12) - (50+50+12) - (60+40+12) - (60+50+12) - (60+60+12) - (80+40+12) - (80+50+12) - (100+50+12) - (120+50+12).OSB thickness: 12 mm
ADVANTAGES - Laying of the ISOVENT 0023 system is practical, rapid and simple. - Large size roofs can be caulked in short timeframes. - The ISOVENT 0023 system is a safe and treadable support. - Individual ventilation channels enable effective ventilation (chimney effect). - The ISOVENT 0023 system provides hassle-free waterproofing.
Thermal conductivity:
ISOVENT 0023®
λD = 0.023
17
ISOSANdWICH®ISOSANdWICH®5000
The ISOSANDWICH®/ISOSANDWICH® 5000 system is a self bearing structural panel which is used to create roofs, flooring and prefabricated walls with the bottom part, heat insulated and ready for subsequent works, on display. Self-bearing panel with sandwich structure ISOSANDWICH®/ ISOSANDWICH® 5000, proves to be a valid and versatile solution for wood or metal structures even where the centre to centre distance exceeds 2 ml. Made up of an OSB panel paired with plywood smooth or stave panels with thickness of 9 mm, a three-layer fir panel with thickness of 14 mm, a single-layer fir panel with thickness of 10 mm, plasterboard sheet (standard, waterproof or fireproof) or 12 mm plaster fibre (see pg. 24) with a panel made from insulating material in between.ISOSANDWICH EPS dimensions 2440x1220 mm = 2.928 m2 rabbeted on long sides.ISOSANDWICH 5000 EPS dimensions 5000x585 mm = 2.925 m2 rabbeted on long sides.ISOSANDWICH GRAFITE dimensions 2440x1220 mm = 2.928 m2 rabbeted on long sides.ISOSANDWICH 5000 GRAFITE dimensions 5000x585 mm = 2.925 m2 rabbeted on long sides.ISOSANDWICH EST dimensions 2440x1220 mm = 2.928 m2 rabbeted on long sides.
ADVANTAGES - multifunctional thermal insulation and energy saving solution for roofs and sloping roofs - no thermal bridges, treadable and safe support in roofs with the laying of a transpiring film - complete protection against accidental infiltration of the roof mantle is achieved - significant installation cost savings
The ISOSANDWICH/ISOSANDWICH 5000 system is used in panels with straight edges or those rabbeted on the 2 long sides.
1 Bottom part on display2 Insulating panel3 Upper part in EUROSTRAND OSB
2
3
1
2
3
1
18
SEMISANdWICH/SEMISANdWICH 5000®
SEMISANDWICH/SEMISANDWICH 5000, is an insulation system made by pairing panels made from waste materials from the first time the EUROSTRAND OSB wood is used, or plywood with phenolic joints and insulation materials.
1 SEMISANDWICH-ESTa 12 mm EUROSTRAND OSB panel paired with an XPS insulating sheet according to Standard EN13164 EC. SEMISANDWICH-EST dimensions 2440x1200 mm = 2.928 m2, rabbeted on long sides
2 SEMISANDWICH-EPS/SEMISANDWICH-EPS 5000 a 12 mm EUROSTRAND OSB panel paired with an EPS insulating sheet according to Standard EN13163 EC.SEMISANDWICH EPS dimensions 2440x1220 mm = 2.928 m2 rabbeted on long sides.SEMISANDWICH 5000 EPS dimensions 5000x585 mm = 2.925 m2 rabbeted on long sides.
3 SEMISANDWICH-GRAFITE/SEMISANDWICH-GRAFITE 5000a 12 mm EUROSTRAND OSB panel paired with an EPS insulating sheet with GRAPHITE according to Standard EN13163 EC.SEMISANDWICH GRAFITE dimensions 2440x1220 mm = 2.928 m2 rabbeted on long sides.SEMISANDWICH 5000 GRAFITE dimensions 5000x585 mm = 2.925 m2 rabbeted on long sides.
4 SEMISANDWICH-LANA DI ROCCIAa 12 mm EUROSTRAND OSB panel paired with a rockwool insulating sheet with density of 160 kg/mc.SEMISANDWICH-LANA DI ROCCIA dimensions 1200x1000 mm = 1.2 m2
5 SEMISANDWICH-FIBRA DI LEGNOa 12 mm EUROSTRAND OSB panel paired with a wood fibre insulating sheet with density of 170 kg/mc.SEMISANDWICH-FIBRA DI LEGNO dimensions 1350x1200 mm = 1.62 m2
Variations upon request: thickness of the OSB on the upper part - panel dimensions.
ADVANTAGES - Laying of the SEMISANDWICH/SEMISANDWICH 5000 system is practical, rapid and simple. - Large size roofs can be caulked in short timeframes. - The SEMISANDWICH system is a safe and treadable support. - The SEMISANDWICH system provides hassle-free waterproofing.
1 2 3 4 5
19
ISOSANdWICH®TOP/ISOSANdWICH®TOP5000
The ISOSANDWICH®-TOP system is a self bearing structural panel which is used to create roofs, flooring and prefabricated walls with the bottom part, heat insulated and ready for subsequent works, on display. Self-bearing panel with sandwich structure ISOSANDWICH®-TOP, proves to be a valid and versatile solution for wood or metal structures even where the centre to centre distance exceeds 2 ml. Made up of an OSB panel and 9 mm smooth or stave plywood panels, a three-layer fir panel with thickness of 14 mm, a single-layer fir panel with thickness of 10 mm, plasterboard sheet (standard, waterproof or fireproof) or 12 mm plaster fibre (see pg. 24) or OSB, with a panel made from insulating material in between and the insertion of solid wood rails using M/F joints across the long sides.ISOSANDWICH-TOP EPS dimensions 2440x1220 mm = 2.928 m2 rabbeted on long sides.ISOSANDWICH-TOP 5000 EPS dimensions 5000x585 mm = 2.925 m2 rabbeted on long sides.ISOSANDWICH-TOP GRAFITE dimensions 2440x1220 mm = 2.928 m2 rabbeted on short sides.ISOSANDWICH-TOP 5000 GRAFITE dimensions 5000x585 mm = 2.925 m2 rabbeted on long sides.ISOSANDWICH-TOP EST dimensions 2440x1220 mm = 2.928 m2 rabbeted on long sides.ISOSANDWICH-TOP LANA DI ROCCIA dimensions 2440x1220 mm = 2.928 m2 rabbeted on long sides.ISOSANDWICH-TOP LANA DI ROCCIA dimensions 5000x585 mm = 2.925 m2 rabbeted on long sides.
ADVANTAGES - multifunctional solution for roofs and sloping roofs - thermal insulation - energy saving - no thermal bridges - treadable and safe support - in roofs with the laying of a transpiring film - complete protection against accidental infiltration of the roof mantle is achieved - significant installation cost savings
2
3
1
4 4
1 Bottom part on display2 Insulating panel3 Upper part in EUROSTRAND OSB4 Solid wood rail with M/F joint which guarantees
greater ability to hold loads with longer centre to centre distances
20
SEMISANDWICH COMPOSITO (EPS/EPS GRAPHITE) AND WOOD FIBRESandwich structure insulation system for roofs. Made up of two layers of insulating material, each with different properties, sintered expanded polystyrene or with graphite additive in compliance with Standard EC 13163 and wood fibre in compliance with Standard EC 13171 with density of 170 kg/mc, coupled with a EUROSTRAND OSB panel in compliance with Standard EN 300 to guarantee the best performance in terms of: thermal insulation, thermal inertia and sound insulation.Semisandwich wood fibre dimensions: 1200x1350 mmVariations upon request: thickness of the OSB on the upper part - panel dimensions.
SEMISANDWICH COMPOSITO (EPS/EPS GRAPHITE) AND ROCKWOOLSandwich structure insulation system for roofs. Made up of two layers of insulating material, each with different properties, sintered expanded polystyrene or with graphite additive in compliance with Standard EC 13163 and rockwool with density of 160 kg/mc coupled with a EUROSTRAND OSB panel in compliance with Standard EN 300 to guarantee the best performance in terms of: thermal insulation, thermal inertia and sound insulation.Semisandwich rockwool dimensions: 1000x1200 mm Variations upon request: thickness of the OSB on the upper part - panel dimensions.
1 The bottom part is in EUROSTRAND OSB2 The insulating panel can be made from:
Sintered expanded polystyrene according to Standard EN 13163 EC Sintered graphite polystyrene according to Standard EN 13163 EC3 Rockwool or wood fibre panel 3
1
SEMISANdWICH®
COMPOSITO
2
21
ISOSANDWICH COMPOSITO/5000 (EPS/EPS GRAPHITE) AND WOOD FIBREThe ISOSANDWICH® COMPOSITO system is used: on flat and inclined roofs, walls, sloping roofs. It enables the achievement of a structural, bearing and treadable surface with the bottom part, heat insulated and ready for subsequent works, on display. The panel is made up of two layers of insulating material, each with different properties: sintered expanded polystyrene or with graphite additive in compliance with Standard EC 13163 and wood fibre in compliance with Standard EC 13171 with density of 170 kg/mc, coupled with a EUROSTRAND OSB panel in compliance with Standard EN 300, whilst the bottom part is available in smooth or stave plywood panels with thickness of 9 mm, a three-layer fir panel with thickness of 14 mm, a single-layer fir panel with thickness of 10 mm, plasterboard sheet (standard, waterproof or fireproof) or 12 mm plaster fibre (see pg. 24). The system guarantees the best performance in terms of: thermal insulation, thermal inertia and sound insulation.ISOSANDWICH COMPOSITO dimensions: 2440x1200 mm = 2.928 m2 rabbeted on short sides.ISOSANDWICH COMPOSITO 5000 dimensions: 5000x585 mm = 2.925 m2 rabbeted on short sides.
ISOSANDWICH COMPOSITO/5000 (EPS/EPS GRAPHITE) AND ROCKWOOLThe ISOSANDWICH® COMPOSITO system is used: on flat and inclined roofs, walls, sloping roofs. It enables the achievement of a structural, bearing and treadable surface with the bottom part, heat insulated and ready for subsequent works, on display. The panel is made up of two layers of insulating material, each with different properties: sintered expanded polystyrene or with graphite additive in compliance with Standard EC 13163 and rockwool with density of 160 kg/mc, coupled with a EUROSTRAND OSB panel in compliance with Standard EN 300, whilst the bottom part is available in smooth or stave plywood panels with thickness of 9 mm, a three-layer fir panel with thickness of 14 mm, a single-layer fir panel with thickness of 10 mm, plasterboard sheet (standard, waterproof or fireproof) or 12 mm plaster fibre (see pg. 24). The system guarantees the best performance in terms of: thermal insulation, thermal inertia and sound insulation.ISOSANDWICH COMPOSITO dimensions: 2440x1200 mm = 2.928 m2 rabbeted on short sides.ISOSANDWICH COMPOSITO 5000 dimensions: 5000x585 mm = 2.925 m2 rabbeted on short sides. Variations upon request: thickness of the OSB on the upper part - panel dimensions.1 The bottom part is in EUROSTRAND OSB2 The insulating panel can be made from:
Sintered expanded polystyrene according to Standard EN 13163 EC Sintered graphite polystyrene according to Standard EN 13163 EC3 Rockwool or wood fibre panel4 Bottom part on display
ISOSANdWICH®
COMPOSITO
1
2
3
4
22
ISOSANdWICH® TOP COMPOSITO
ISOSANDWICH TOP COMPOSITO/5000 (EPS/EPS GRAPHITE) AND WOOD FIBREThe ISOSANDWICH® TOP COMPOSITO system is used: on flat and inclined roofs, walls, sloping roofs. It enables the achievement of a structural, bearing and treadable surface with the bottom part, heat insulated and ready for subsequent works, on display. The panel is made up of two layers of insulating material, each with different properties: sintered expanded polystyrene or with graphite additive in compliance with Standard EC 13163 and wood fibre in compliance with Standard EC 13171 with density of 170 kg/mc, coupled with a EUROSTRAND OSB panel in compliance with Standard EN 300, whilst the bottom part is available in smooth or stave plywood panels with thickness of 9 mm, a three-layer fir panel with thickness of 14 mm, a single-layer fir panel with thickness of 10 mm, plasterboard sheet (standard, waterproof or fireproof) or 12 mm plaster fibre (see pg. 24) and the insertion of solid wood rails using M/F joints across the long sides. The system guarantees the best performance in terms of:thermal insulation, thermal inertia and sound insulation.Isosandwich top composito wood fibre dimensions: 2440x1200 mm = 2.928 m2
Isosandwich top 5000 wood fibre dimensions: 5000x585 mm = 2.925 m2
Variations upon request: thickness of the OSB on the upper part - panel dimensions.ISOSANDWICH TOP COMPOSITO/5000 (EPS/EPS GRAPHITE) AND ROCKWOOLThe ISOSANDWICH® TOP COMPOSITO system is used: on flat and inclined roofs, walls, sloping roofs. It enables the achievement of a structural, bearing and treadable surface with the bottom part, heat insulated and ready for subsequent works, on display. The panel is made up of two layers of insulating material, each with different properties: sintered expanded polystyrene or with graphite additive in compliance with Standard EC 13163 and rockwool with density of 160 kg/mc, coupled with a EUROSTRAND OSB panel in compliance with Standard EN 300, whilst the bottom part is available in smooth or stave plywood panels with thickness of 9 mm, a three-layer fir panel with thickness of 14 mm, a single-layer fir panel with thickness of 10 mm, plasterboard sheet (standard, waterproof or fireproof) or 12 mm plaster fibre (see pg. 24) and the insertion of solid wood rails using M/F joints across the long sides. The system guarantees the best performance in terms of: thermal insulation, thermal inertia and sound insulation.Isosandwich top rockwool dimensions: 2440x1200 = 2.928 m2
Isosandwich top 5000 rockwool dimensions: 5000x585 mm = 2.925 m2 Variations upon request: thickness of the OSB on the upper part - panel dimensions.
1 The bottom part is in EUROSTRAND OSB2 The insulating panel can be made from:
Sintered expanded polystyrene according to Standard EN 13163 EC Sintered graphite polystyrene according to Standard EN 13163 EC3 Rockwool or wood fibre panel4 Bottom part on display
1
2
3
4
23
ISOSANdWICH® SPECIAL
ISOSANDWICH SPECIALInsulation system with sandwich structure made up of a panel with insulating core paired with, on both sides, a EUROSTRAND OSB panel according to Standard EN 300 EC or with the addition of a plasterboard panel(standard, waterproof or fireproof) or 12 mm plaster fibre on side on display.The panel can be straight edged, rabbeted or reinforced across the long sides with wood rails and M/F joint.Dimensions: 2440x1200 mm = 2.928 m2
Variations upon request: thickness of the OSB on the upper part - panel dimensions
ADVANTAGES - multifunctional solution for roofs and sloping roofs - thermal insulation - energy saving - no thermal bridges - treadable and safe support - in roofs with the laying of a transpiring film
- complete protection against accidental infiltration of the roof mantle is achieved - significant installation cost savings
1 The bottom part on display is in EUROSTRAND OSB2 The insulating panel can be made from:
Sintered expanded polystyrene according to Standard EN 13163 EC
Sintered graphite polystyrene according to Standard EN 13163 EC
Extruded polystyrene according to Standard EN 13164 EC, rockwool upon request
3 The upper part is a EUROSTRAND OSB panel4 Solid wood rail with M/F joint5 The bottom part is in plasterboard/plaster fibre
2
3
1
4 4
2
2
3
3
1
1
ISOSANDWICH® 2 KISOSANDWICH® TOP 2 K
ISOSANDWICH® 2 K + PLASTERBOARDISOSANDWICH® TOP 2 K + PLASTERBOARD
ISOSANDWICH® 2 K + PLASTER FIBREISOSANDWICH® TOP 2 K + PLASTER FIBRE
5
2
3
1
4 4
5
24
ISOSANdWICH RANGE dIMENSIONAL INFORMATION
6 7
DISPLAYED BOTTOM PART FINISHES
Description Panel dimensions
ISOSANDWICH/TOP length 2440 mm x width 1200 mm
ISOSANDWICH/TOP 5000 length 5000 mm x width 585 mm
ISOSANDWICH 2K/TOP 2K length 2440 mm x width 1200 mm
ISOSANDWICH 2K 5000 length 5000 mm x width 585 mm
ISOSANDWICH 2K/TOP 2K PLASTERBOARD length 2440 mm x width 1200 mm
Description Panel thickness
ISOSANDWICH/TOP from 51 to 241 mm
ISOSANDWICH/TOP 5000 from 66 to 246 mm
ISOSANDWICH 2K/TOP 2K from 54 to 244 mm
ISOSANDWICH 2K 5000 from 54 to 244 mm
ISOSANDWICH 2K/TOP 2K PLASTERBOARD from 67 to 247 mm
1_PLYWOOD IN SMOOTH CHILEAN PINE 9 MM
2_PLYWOOD IN STAVE CHILEAN PINE 9 MM
3_THREE-LAYER SMOOTH FIR PANEL 14 MM
4_THREE-LAYER STAVE FIR PANEL 14 MM
5_SINGLE-LAYER STAVE FIR PANEL -10-14 MM
6_PLASTERBOARD PANEL 12.5 MM
standard
waterproof
fireproof
7_PLASTER FIBRE 12 MM
1 32 4
5
25
1_PLYWOOD IN SMOOTH CHILEAN PINE 9 MM
2_PLYWOOD IN STAVE CHILEAN PINE 9 MM
3_THREE-LAYER SMOOTH FIR PANEL 14 MM
4_THREE-LAYER STAVE FIR PANEL 14 MM
5_SINGLE-LAYER STAVE FIR PANEL -10-14 MM
6_PLASTERBOARD PANEL 12.5 MM
standard
waterproof
fireproof
7_PLASTER FIBRE 12 MM
TECHNICAL SPECIFICATIONS OF EPS - EST SINTERED EXPANDED POLYSTYRENE BEFORE PAIRING
Description Class U.M. EPS 100 EPS 150 EPS 200 EST Standard graphiteDim.stability DS(N) % ±5 ±5 ±5 ±5 UNI EN 1603
Bending strength BS kPa �150 �200 �250 UNI EN 12089
Compression resistance CS(10) kPa �100 �150 �200 �300 UNI EN 826
Water vapour diffusion resistance MU 30-70 70-90 90-120 80/150 UNI EN 12086
Thermal conductivity λD 0.031 0.034 0.034 0.034/0.036 UNI EN 13163Fire performance E E E E UNI EN 13501/1
Thermal ability J/kgK 1260 1260 1260 1260
EXPANDED POLYURETHANE 0.023 PROPERTIES
Thermal Insulation
Euroclass F
E
1453
20 30 40 50 60 70 80 90 100 120
0.022
0.023
1.15 0.77
0.87 1.30 1.74 2.17 2.61 3.04 3.48 3.91 4.35 5.22
0.58 0.46 0.38 0.33 0.29 0.26 0.23 0.19
Euroclass
Cp(J/kg K)
foam
Properties(Standard) Description
Symbol(Unit of
measurement)
ValueSome properties vary based upon the thickness (mm)
λ90/90.l
(W/mK)
UD(W/m2K)
RD(m2K/W)
λD(W/mK)
Value established at anaverage temperature of 10°C
Value established at anaverage temperature of 10°C
UD=λD/d
RD= d /λD
Initial average thermal conductivity(EN 12667)
Stated Thermal Conductivity
(UNI EN 13165Annexes A and C)
Stated Thermal Transmittance
Stated Thermal Resistance
Euroclass Fire performance(EN 13501-1)(EN 11925-2)(13823 (SBI))
Euroclass Fire performance(EN 11925-2)
Specific Heat
26
INSULATION TECHNICAL SPECIFICATIONSISOVENT/TOP-ISOSANdWICH/TOP
ROCKWOOL WITH DENSITY OF 160 KG/MC Description U.M. value standard
Nominal density (±10%)
thicknesses 30, 40, 50, 60, 80 kg/m3 160 EN 1602
thicknesses 100, 120, 140 kg/m3 155 EN 1602
Thermal conductivity λD W/mK 0,039 EN 13162 EN 12667
Fire performance (Euroclass) A1 EN 13501-1
Specific heat (Cp) J/kgK 1.030 EN 12524
Resistance to the flow of water vapour without covering µ 1 EN 12086
Long-term water absorption WL(P) kg/m2 � 3.0 EN 1609
Dimensional stability in specific temperature and humidity conditions DS(TH)[tested for 48 hours at (70± 2)°C and (90±5) %UR] 1% EN 1604
Resistance to the flow of air - AF kPa - s/m2 >60 EN 29053
Resistance to compression with10% crushing - CS(10)Thicknesses 30, 40, 50 kPa ≥ 50 EN 826Thicknesses 60, 80, 100, 120, 140 kPa ≥ 70 EN 826
NATURAL LIGHT CORKDescription U.M. value standard
Nominal density (±10%) kg/m3 130 EN 1602
Thermal conductivity λD W/mK 0,043
Transpirability to water vapour µ 10�13
Putrescibility none
27
WOOD FIBREDescription technical specifications
Profile level edges
Fire performance class according to Standard EN 13501-1 E
Material class according to Standard DIN 4102 B2
Thermal conductivity coefficient λD(W/(m*K) 0.039
Density [kg/m3] approx. 160-170
Water vapour diffusion resistance µ 5
Value sd (m) 0.1/0.2/0.3/0.4/0.5/0.6/0.7/0.8
Specific heat c [J/(kg*K)] 2100
Bending strength at 10% compression σ 10 (N/mm2) 0.05
Resistance to compression [kPa] 50
Shock resistance (kPa) ≥ 2.5
Hydraulic resistance relative to length [(kPa*s)/m2] ≥ 100
Components layered wood fibre
Waste code (EAK) 030105/170201
INSULATION TECHNICAL SPECIFICATIONS
EUROSTRAND OSB ACCORDING TO STANDARD EN 300
Description OSB 2 OSB 3 U.M. Standard
Panel thickness 10�18 10�25 10�18 10�25
Apparent specific weight 580-620 610-660 Kg/m3
Modulus of elasticity
primary axis 3500 3500 5000 5000 N/mm2 EN 310secondary axis 1400 1400 2000 2000
Bending strength
primary axis 20 18 20 18 N/mm2 EN 310secondary axis 10 9 10 9
Transverse tensile strength with dry fibres 0.34 0.32 0.34 0.32 N/mm2 EN 319
Dimensional variation rel. hum. 85% 35% length +0.10-0.15owing to humidity thickness +5.0-1.5 % EN 318
Subsequent swelling 24 h 15 15 10 10 % EN 317
Resistance to diffusion of water vapour sd �2.0 M DIN 52615
Fire performance class B2
Thermal conductivity 0.13 W/mk DIN 52615
28
PLASTER FIBRE
Description U.M. value
Nominal density Kg/m3 1150±50
Thermal conductivity λ W/mk 0.32
Specific heat kJ/KgK 1.1
Swelling of thickness 24 h subsequent to being in water % 2
Fire performance class according to Ministerial Decree 26/06/1984 0
Adm bending perpendicular to sheet surface N/mm2 1.2
Modulus of elasticity perpendicular to sheet surface N/mm2 3800
Compression modulus N/mm2 3800
FINISHES TECHNICAL SPECIFICATIONS
PLASTERBOARD EN 520Description U.M. value standard
Thickness mm 12.5
Weight Kg/m2 10.0
Water vapour diffusion resistance µ 70-200 EN 12524
Bending strength: Longitudinal N 550 EN 520-512 Transverse 210
Fire performance class A2 EN 520
29
PLYWOOD 9 MM EN 310 (EC)
Description U.M. value standard
Density Kg/mc ˜500 Kg/mc EN 323
Thermal conductivity λ (W/m2K) 0.13 EN 13986
Resistance to diffusion
of water vapour µ 70-200 EN 12524
Fire behaviour Euroclass D EN 13501
Modulus of elasticity MOE N/mm2 parallel 7.43
perpendicular 754
Bending strength MOR N/mm2 parallel 72
perpendicular 15
THREE-LAYER FIR 14 MM EN 13986 (EC)
SINGLE-LAYER FIR 10 MM
Description U.M. value standard
Density Kg/mc ˜500 Kg/mc EN 323
Thermal conductivity λ (W/m2K) 0.13 EN 13986
Resistance to diffusion
of water vapour µ 70-200 EN 12524
Fire behaviour Euroclass D EN 13501
Bending strength MOR N/mm2 parallel 9000
perpendicular 600
Resistance to pressure N/mm2 parallel 32
perpendicular 5
Description U.M. value standard
Density Kg/mc ˜500 Kg/mc EN 323
Thermal conductivity λ (W/m2K) 0.13 EN 13986
Resistance to diffusion
of water vapour µ 70-200 EN 12524
Fire behaviour Euroclass D EN 13501
Bending strength MOR N/mm2 parallel 20
perpendicular 5
Modulus of elasticity MOE N/mm2 parallel 3.00
perpendicular 270
FINISHES TECHNICAL SPECIFICATIONS
30
TERMOSYSTEM® EPS
TERMOSYSTEM® EPS is a system made up of a bituminous membrane paired with a sintered expanded polystyrene insulating panel, according to Standard UNI EN 13163, delayed flame fighting action, Euroclass E.
Standard product type.Roll: stave width 50 mm - roll height 1 ml with selvage of 8-10 cm on one side, recommended for a thickness of up to 60 mm. Sheets for thicknesses of 70 mm to 200 mm.Pre-cut sheets: stave width 50 mm - roll height 1 ml with selvage on one long side and two selvages on short side used for the heat insulation of prefabricated roofing tiles.Panels: all thicknesses available, width 1 ml, minimum length 2 ml with two 8-10 cm selvages on long and short side.Pre-cut panels:all thicknesses available, width 1 ml, custom length with precuts relative to the roof type, two 8-10 cm selvages on long and short side.
TECHNICAL SPECIFICATIONS OF EPS SINTERED EXPANDED POLYSTYRENE BEFORE PAIRING
Description Class U.M. EPS 80 EPS 100 EPS 120 EPS 150 EPS 200 EPS 250 Standard
Dim. stability DS(N) % ±5 ±5 ±5 ±5 ±5 ±5 UNI EN 1603
Bendingstrength BS kPa �125 �150 �170 �200 �250 �350 UNI EN 12089
Compressionresistance CS(10) kPa �80 �100 �120 �150 �200 �250 UNI EN 826
Water vapourdiffusionresistance MU 20-40 40-60 60-80 70-90 90-120 40-100 UNI EN 12086
Thermal conductivity λD 0.038 0.036 0.035 0.034 0.034 0.033 UNI EN 13163Fire performance E E E E E E UNI EN 13501/1
Thermal ability J/kgK 1260 1260 1260 1260 1260 1260
31
TERMOSYSTEM® EPS GRAFITE
TERMOSYSTEM® EPS GRAFITE is a system made up of a bituminous membrane paired with a sintered expanded polystyrene insulating panel with graphite additive, according to Standard UNI EN 13163, delayed flame fighting action, Euroclass E.
Product type.Roll: stave width 50 mm - roll height 1 ml with selvage of 8-10 cm on one side, recommended for a thickness of up to 60 mm. Sheets for thicknesses of 70 mm to 200 mm.Pre-cut sheets: stave width 50 mm - roll height 1 ml with selvage on one long side and two selvages on short side used for the heat insulation of prefabricated roofing tiles.Panels: all thicknesses available, width 1 ml, minimum length 2 ml with two 8-10 cm selvages on long and short side.Pre-cut panels:all thicknesses available, width 1 ml, custom length with precuts relative to the roof type, two 8-10 cm selvages on long and short side.
TECHNICAL SPECIFICATIONS OF EPS GRAPHITE SINTERED EXPANDED POLYSTYRENE BEFORE PAIRING
Description Class U.M. EPS 100 GRAFITE EPS 150 GRAFITE Standard Dimensional stability DS(N) % ±5 ±5 UNI EN 1603
Bendingstrength BS kPa ≥100 ≥250 UNI EN 12089
Compressionresistance CS(10) kPa ≥100 ≥150 UNI EN 826
Water vapour diffusionresistance MU µ 40-60 70-90 UNI EN 12086
Thermal conductivity λD 0.031 0.030 UNI EN 13163Fire performance E E UNI EN 13501/1
Thermal ability J/kgK 1260 1260
32
TERMOSYSTEM® EST
TECHNICAL SPECIFICATIONS OF EXTRUDED EXPANDED POLYSTYRENE BEFORE PAIRING
Description Class U.M. EST Standard
Dimensional stability DS(TH) % ±5 UNI EN 1603
Resistance to compressionwith 10% crushing CS(10/Y) kPa ≥300 UNI EN 826
Level of deformation DLT(2)5 % ≤5 UNI EN 1605
Resistance to compression subsequent to 50 years with crushing ≤ 2 % CC(2/1.5/50) Kpa 130 UNI EN 1606
Long-term waterabsorption for diffusion WD(V)5 Vol. -% 2-4 UNI EN 12086
Water vapour diffusion resistance MU µ 100 UNI EN 12088
Thermal conductivity λD 0.034-0.036* UNI EN 13164
Fire performance E UNI EN 13501/1
Thermal ability J/kgK 1260
TERMOSYSTEM® EST is a system made up of a bituminous membrane paired with an extruded expanded polystyrene insulating panel, according to Standard UNI EN 13164, delayed flame fighting action, Euroclass E.
Product type.Roll: stave width 50 mm - roll height 1 ml with selvage of 8-10 cm on one side, available for a thickness of up to 60 mm.Panels: all thicknesses available, width 1 ml, length 1.20-1.80-2.40 ml with two 8-10 cm selvages on long and short side.
*Dependent on thickness
33
TERMOSYSTEM® PUR VP
TERMOSYSTEM® PUR VP is a system made up of a bituminous membrane paired with an expanded polyurethane insulating panel, according to Standard EN 13165, delayed flame fighting action, Euroclass E.VP: Saturated Glass Fibre.Product type.
Roll: stave width 50 mm - roll height 1 ml with selvage of 8-10 cm on one side, from 20 to 120 mm with saturated glass fibre coating on both sides.Panels: all thicknesses available, width 1 ml, length 1.20-2.40 ml with two 8-10 cm selvages on long and short side.
TECHNICAL SPECIFICATIONS OF PUR EXPANDED POLYSTYRENE BEFORE PAIRINGDescription Symbol Value Standard
Calculated conductivity λD W/mK 0.028 per th. from 20 to 70 mm UNI EN 13165measured at +10°C λD W/mK 0.026 per th. from 80 to 140 mm UNI EN 13165
Resistance to compression with 10 % crushing dN from 30 to 40 mm kPa 150 UNI EN 826
Dimensional stability DS(TH) (48±1)h length variation % 1 (70±2)°C
Fire performance European Class VP EN 11952/2 Euroclass E UNI EN 13501/1
Thermal ability J/kgK 1260
34
TERMOSYSTEM® PUR 0.023
TERMOSYSTEM® PUR 0.023 is a system made up of a bituminous membrane paired with a rigid polyiso foam panel according to Standard UNI EN 13165. Standard product type.
Panels: standard thicknesses from 20 to 120 mm, width 1 ml minimum length 1.2/2.4 ml with two side overlapping 10 cm selvages.
Thermal Insulation
Euroclass F
E
1453
20 30 40 50 60 70 80 90 100 120
0.022
0.023
1.15 0.77
0.87 1.30 1.74 2.17 2.61 3.04 3.48 3.91 4.35 5.22
0.58 0.46 0.38 0.33 0.29 0.26 0.23 0.19
Euroclass
Cp(J/kg K)
foam
Properties(Standard) Description
Symbol(Unit of
measurement)
ValueSome properties vary based upon the thickness (mm)
λ90/90.l
(W/mK)
UD(W/m2K)
RD(m2K/W)
λD(W/mK)
Value established at anaverage temperature of 10°C
Value established at anaverage temperature of 10°C
UD=λD/d
RD= d /λD
Initial average thermal conductivity(EN 12667)
Stated Thermal Conductivity
(UNI EN 13165Annexes A and C)
Stated Thermal Transmittance
Stated Thermal Resistance
Euroclass Fire performance(EN 13501-1)(EN 11925-2)(13823 (SBI)
Euroclass Fire performance(EN 11925-2)
Specific Heat
TECHNICAL SPECIFICATIONS OF PUR 0.023 EXPANDED POLYSTYRENE BEFORE PAIRING
35
Some properties vary based upon the thickness (mm)
TERMOSYSTEM® RC
TERMOSYSTEM® RC is a system made up of a bituminous membrane paired with an oriented strand mineral wool insulating panel with density of 155 kg/mc, according to Standard UNI EN 13162, delayed flame fighting action, Euroclass A1.Standard product type.
Roll: stave width 50 mm - roll height 1 ml with selvage of 8-10 cm on one side, available for a thickness of up to 60 mm.Panels: all thicknesses available, width 1 ml, minimum length 1.2 ml with two 8-10 cm selvages on long and short side.
TECHNICAL SPECIFICATIONS OF RC MINERAL WOOL BEFORE PAIRING
Description Class U.M. Value StandardTolerance class relative to dimensional parameters T5 UNI EN 823Resistance to compression with 10% crushing CS(10) kPa ≥ 70 UNI EN 826
Tensile strength across thickness kPa ≥ 13 UNI EN 1607Linear thermal expansion coefficient 2x10-6 °C-1
Residue withdrawal at 20 °C subsequent to 4 days at 70°C negligible UNI EN 12086
Linear expansion at a constant longitudinal direction < 1 mm/mtemperature of 20°C between 65 and 80% UR transverse direction < 1 mm/m
Thickness variation of samples kept for 15 mins. at 100°C and UR 100% and then cooled to room temperature 2%
Short-term water absorption-WS kg/m2 ≤ 1.0Euroclass Fire performance European Class A1Thermal conductivity λD 0.040Resistance to concentrated load PL (5) N 650 EN 12430Rockwool melting temperature °C > 1000Thermal ability J/kgK 980
36
TERMOSYSTEM® COMPOSITO
TERMOSYSTEM® COMPOSITO is a sintered expanded polystyrene panel with graphite additive, high density rockwool according to Standard EC 13162, and a bituminous membrane, excellent for roof heat insulation and soundproofing.Dimensions: 1200x1000 mm.Thicknesses available upon request dependent on requirements.
See graphite specifications on page 25See rockwool specifications on page 28
37
TERMOSYSTEM COMPOSITO FESCO S/EPS OR EXTRUDED is an insulating system made up of an expanded perlite insulating sheet, with oxidised bitume coating on one side (approx. 350 g/m2), protected by a thermal fuse film and an elasticated expanded polystyrene sheet according to EN 13163 or an extruded expanded polystyrene sheet according to Standard EN 13164. Rabbeted on 4 sides upon request.Dimensions: 1200x600 mmInsulation thicknesses: 30-40-50-60-80-100 mm
TECHNICAL SPECIFICATIONS OF FESCO BEFORE PAIRINGCharacteristics Value Unit Standard
Length, width 1200 x 600 mm EN 822
Thickness From 20 to 120 mm EN 823
Nominal density 150 kg/m3 EN 1602
Stated thermal conductivity, λD 0.050 W/m.K EN 13169
Compression crushing at 10% deformation ≥ 200 (average 300) kPa EN 826
Under cement slab performance characteristics:
- crushing under compression, RCS 130 kPaEN 826
- deformation, dSmin / dSmax 0.7-1.2 %
Deformation at 80 kPa and 80°C for 7 days (or 7 days at 60°C according to EN 1605) < 5 (2 %) % UEAtc
Deformation (Creep) under compression at 80 kPa extracted after 10 years ≤ 1 mm EN 1606
Resistance to punching (across 50 cm2) with 2 mm of deformation ≥ 1400 N EN 12430
Water absorption when fully immersed ≤ 0.03 kg/dm3 EN 13169
Dimensional stability - after 48h at 23°C and 90% UR, length and width/thickness ≤ 0.5-1.0 % EN 1604
- after 48h at 70°C and 50% UR, length and width/thickness ≤ 0.5-1.0 % EN 1604
- creep deformation at 20° subsequent to stabilization at 80°C < 0.12 % UEAtc
Resistance to tensile strength perpendicular to sides ≥ 40 kPa EN 1607
Specific heat 900 J/kg.K EN ISO 10456
Water vapour diffusion resistance, μ 5 - EN ISO 10456
Fire performance (Euroclass) C-s1, d0 - EN 13501-1
TECHNICAL SPECIFICATIONS OF EPS 200 KPADescription compression value
(EN 826)thermal conductivity
(EN 13163)MU
(EN 12086)fire performance
Euroclass
EPS Kpa 200 λD 0.034 µ 70-90 E (EN 13501/1)
TECHNICAL SPECIFICATIONS OF EST 350 KPADescription compression value
(EN 826)thermal conductivity
(EN 13163)MU
(EN 12086)fire performance
Euroclass
EST Kpa 350 λD 0.034-0.036 µ 150 E (EN 13501/1)
TERMOSYSTEM® COMPOSITO FESCO S/EPS - FESCO S/EST
38
TERMOSYSTEM® ONDA
TERMOSYSTEM ONDA is a system made up of a waterproof bituminous membrane and an EPS or EPS insulating panel, with graphite additive shaped according to the type of cement fibre or asbestos corrugation, on top of which it is laid. In the case of vault roofs TERMOSYSTEM ONDA is suitably precut. The panels are provided with two overlapping selvages on the two perpendicular sides.
Curved system
TERMOSYSTEM® GRECA
TERMOSYSTEM GRECA is a system made up of a waterproof bituminous membrane and an EPS or EPS insulating panel, with graphite additive shaped according to the type of corrugated metal sheet, on top of which it is laid. In the case of vault roofs TERMOSYSTEM GRECA is suitably precut. The panels are provided with two overlapping selvages on the two perpendicular sides.
Curved system
39
TERMOSYSTEM® GRECA
TERMOSYSTEM® PENDENZA
TERMOSYSTEM® SLOPING FOR PHOTOVOLTAIC INSTALLATION
TERMOSYSTEM PENDENZA is a waterproof insulation system made up of sintered expanded polystyrene according to Standard EN 13163 or with graphite additive according to Standard EN 13163 and a bituminous membrane according to Standard EN 13707.
System used to determine the average thickness of TERMOSYSTEM inclinations
TERMOSYSTEM SLOPING FOR PHOTOVOLTAIC INSTALLATION is a waterproof insulation system made up of sintered expanded polystyrene or graphite additive according to Standard EN 13163 and a 20 mm expanded polyurethane sheet according to Standard EN 13165 coated on both sides with saturated glass and a bituminous sheath or a 12 mm thick EUROSTRAND OSB panel according to Standard EN 300.Panel dimensions: 1200x1000 mm
Calcolo dello spessore medio: H1+h/2= SM (spessore medio)
1000
h
= = =
LUNGHEZZA
H1
Pendenza %
Calculation of average thickness: H1+h/2= SM (average thickness)
Inclination %
LENGTH
40
TERMOSYSTEM® PENDENZA
2>
1> 1> 1>
<1 <1 <12>
3>
3>
3>
3>2> 2> 2>
3> 3> 3>
4> 4> 4>
5> 5> 5>
<2 <2 <2
<3 <3 <3
<2
<3 <32>
3> 3>
4> 4> 4>
<4 <4 <4
<5 <5 <5
<6 <6 <6
<7 <7 <7
<4 <4 <4
<5 <5 <5
<6 <6 <6
<7 <7 <7
<5
<6 <6
<7 <7 <7
7> 7> 7>7>6> 6> 6> 6>
5> 5> 5> 5>
4>
4>
4>
4>
5>
5>
5>
5>
6>
6>
6>
6>
7>
7>
7>
7>
8>
8>
8>
8>
4>5>
5>
6>
6>
6>
7>
7>
7>
8>
8><1 <1 <1
<2 <2
<3
<2
<3 <3
<4 <4 <4
<5 <5 <5
<6 <6 <6
<7 <7 <7
<1 <1 <1
<2 <2<3
<1 <1 <1
<2 <2
<3
<2
<3 <3
<4 <4 <4
<5 <5<6
<1<2
<3<4
<5<6
<7
<1
<1
<1
<2
<2
<3
<3
<4
<4
<5
<5
<2 <3 <4
5>
6>
6>
7>
7>
7>
8>
8>
8>
8>
4>5>6>7>8>
9>10>
11>12>
15>14>
13>
<2<3 <3
<4 <4 <4
<5 <5 <5 <5
<6
<6
<6 <6 <6 <6 <6
<7
<5
<6
9>10>
11>12>
15>14>
13>
9>10>
11>12>
15>14>
13>
9>10>
11>12>
15>14>
13>
9>10>
11>12>
15>14>
13>
9>10>
11>12>
15>14>
13>
9>10>
11>12>
15>14>
13>
9>10>
11>12>
15>14>
13>
9>10>
11>12>
15>14>
13>
9>10>
11>12>
15>14>
13>
160 mm
170 mm
180 mm
190 mm
200 mm
210 mm
220 mm
230 mm
202 mm
175 mm
148 mm
121mm
94 mm
67 mm
40 mm
67 mm
230 mm
202 mm
175 mm
148 mm
121mm
94 mm
67 mm
40 mm
94 mm
121 mm
148 mm
175 mm
202 mm
DESIGN TYPICAL OF A FLAT ROOF WITH DRAINPIPES AND GUTTER CHANNELS "MULTI-DRAINAGE SYSTEM"This type of system enables the channelling of rainwater, by means of the inclined modules across the compluviums to be dispelled to the drain or gutter channels.The inclined Termosystem comes in various types of tapered EPS sheets dependent on design requirements.Individual sheets (not paired) can be produced for solutions which include synthetic mantles, or paired sheets for polymer bitumen membranes for the subsequent application of layers to result in bituminous solutions.Our technical office is always available to provide clarification.
41
TERMOSYSTEM® TEGOLO
TERMOSYSTEM TEGOLO is system which includes customised PSE or PSE with graphite additive shaped sheets, paired with bituminous membranes providing insulation and waterproofing of prefabricated roofing tiles.
42
TERMOSYSTEM® COPPO P
TERMOSYSTEM® COPPO P is a waterproof insulation system made up of sintered expanded polystyrene or graphite additive according to Standard UNI EN 13163, which is specifically shaped to house the curved tiles and a 3.5 kg/m2 bituminous membrane reinforced with polyester TNT and self-protected with slate components according to Standard UNI EN 13707.
Termosystem® coppo P thicknessA 30-40-50-60-70-80-90-100-110-120 mm
TERMOSYSTEM® COPPO G
TERMOSYSTEM® COPPO G is a waterproof insulation system made up of sintered expanded polystyrene or graphite additive according to Standard UNI EN 13163, which is specifically shaped to house the curved tiles and a 3.5 kg/m2 bituminous membrane reinforced with polyester TNT and self-protected with slate components according to Standard UNI EN 13707.
Termosystem coppo G thicknessA 30-40-50-60-70-80-90-100-110-120 mm
43
TERMOSYSTEM COPPO P PANEL SHAPE AND DIMENSIONS
Description value
Panel dimensions 1860x1000 mm
Usable surface 1.86 m2
Requirements per 100 m2 roof 54 pcs.
TERMOSYSTEM® COPPO GV
TERMOSYSTEM COPPO G PANEL SHAPE AND DIMENSIONS
Description value
Panel dimensions 1800x1000 mm
Usable surface 1.80 m2
Requirements per 100 m2 roof 54 pcs.
TERMOSYSTEM® COPPO GV is a waterproof insulation system made up of sintered expanded polysty-rene or graphite additive according to Standard UNI EN 13163, which is specifically shaped with micro-ventilation to house the curved tiles and a 3.5 kg/m2 bituminous membrane reinforced with polyester TNT and self-protected with slate components according to Standard UNI EN 13707.
Termosystem® coppo GV thicknessA 30-40-50-60-70-80-90-100-110-120 mm
Ventilation channels
TERMOSYSTEM COPPO GV PANEL SHAPE AND DIMENSIONS
Description value
Panel dimensions 1800x1000 mm
Usable surface 1.80 m2
Requirements per 100 m2 roof 54 pcs.
44
TERMOSYSTEM TEGOLA is a waterproof insulation system made up of sintered expanded polysty-rene or graphite additive according to Standard UNI EN 13163, which is specifically shaped to house the splints supporting the counterbatten to attach the tiles, paired with a 3.5 kg/m2 bituminous membrane reinforced with polyester TNT and self-protected with slate components according to Standard UNI EN 13707. Dimensional specifications:- Length 1800 - width 1000 - m2 1.80- 1 selvage on short side and 1 selvage on long side- Selvage overhang: 10 cm˜- 3 50x40 mm splints
TILE EASY is a roof under tile heat insulation sheet made up of single-layer extruded polystyrene with compression resistance of 300 Kpa, with extruded layer, two edges rabbeted with M/F joint or sintered expanded polystyrene with compression resistance of 200 Kpa, two longitudinal grooves for micro ventilation* and transverse grooves** to slot the teeth of the aforementioned. The sheet is 600 mm wide, available in various thicknesses and lengths dependent on the tile pitch. * and any water drainage in the case of infiltration of the roof mantle** with tile pitchDimensional specifications:
Finish Thickness mm Standard pitch mm Length mm
rabbeted with M/F joint.on long side
40-50-60-80-100-120 315-330-345* 2520-2640-2760
*upon the request of special pitches
TERMOSYSTEM® TEGOLA
TILE EASYSHEETS FOR UNDER TILE HEAT INSULATION
EXTRUDED EPS
45
A
ISOLONDA®190-220 is made up of an EPS 150/200 kPa or 100 kPa graphite panel according to UNI EN 13163 suitably paired with a fibrous bituminous mantle, resulting in optimal ventilation between the system and the roof mantle. Such a panel is used both for curved tiles and roof tiles, the lastly mentioned with the application of a splint dependent on the tile pitch.Dimensions:
EPS sheet measurement 1920X968Fibrous bituminous sheet measurement 2000X1050Usable surface 1.86 m2
ISOLONDA® P 190 - 220
Isolonda 190-220 thicknessA 30-40-50-60-80-100-120 mm
EPS dimensions 986 mm
Dimensions of fibrous bitum
inous mantle 2000 m
m
EPS 150/200 KPA INSULATION EPS 100 KPA GRAFITE INSULATION
46
ISOLONDA® C
BA
ISOLONDA®-C features a standard wave and two channels under the fibrous bituminous mantle, the EPS 150/200 kPa or 100 kPa graphite panel according to UNI EN 13163 is specifically shaped and paired with a fibrous bituminous sheet. The standard wave represents a secure housing for curved tiles facilitating installation.Dimensions:
EPS sheet measurement 1920X875Fibrous bituminous sheet measurement 2000X950Usable surface 1.68 m2
EPS 150/200 KPA INSULATION EPS 100 KPA GRAFITE INSULATION
Isolonda C ThicknessA 30-40-50-60-80-100-120 mm
B 60-70-80-90-110-130 mm Ventilation channels
EPS dimensions 875 mm
Dimensions of fibrous bituminous mantle 2000 mm
47
GESS FON EPS/GRAFITE
TECHNICAL CHARACTERISTICSGESS FON PSE® e GESS FON PSE GRAFITE® are panels with optimal heat insulation performance made up of a RB 13 plasterboard sheet according to Standard UNI EN 520 (standard, fireproof, waterproof) and a TERMOSTYR® or TERMPOR® sintered expanded polystyrene panel according to Standard EN 13163 EC delayed flame fighting action, Euroclass E. Dimensions: 1200x2000/3000 mm Insulation thicknesses: 20-30-40-50-60-80-100-120
TECHNICAL SPECIFICATIONS OF EPS SINTERED EXPANDED POLYSTYRENE BEFORE PAIRINGDescription Class U.M. EPS 80 EPS 100 EPS 150 EPS100 grafite Standard
Dim. stability DS(N) % ±5 ±5 ±5 ±5 UNI EN 1603
Bending strength BS kPa �125 �150 �200 �150 UNI EN 12089
Compressionresistance CS(10) kPa �80 �100 �150 �100 UNI EN 826
Water vapourdiffusionresistance MU 20-40 40-60 70-90 30-70 UNI EN 12086
Thermal conductivity λD 0.038 0.036 0.034 0.031 UNI EN 13163Fire performance E E E E UNI EN 13501/1
Thermal ability J/kgK 1260 1260 1260 1260
48
GESS FON EST
TECHNICAL CHARACTERISTICSSystem which includes an RB 13 standard, fireproof or waterproof plasterboard sheet according to Standard UNI EN 520 and an extruded expanded polystyrene panel according to Standard UNI EN 13164. Used with plasterboard structures or cladded to walls or roofs to provide heat insulation. Dimensions: 3000X1200 mm/2000x1200Insulation thicknesses: 20-30-40-50-60-80
TECHNICAL SPECIFICATIONS OF EXTRUDED EXPANDED POLYSTYRENE BEFORE PAIRINGDescription Class U.M. EST Standard
Dimensional stability DS(TH) % ±5 UNI EN 1603
Resistance to compressionwith 10 % crushing CS(10/Y) kPa ≥250 UNI EN 826
Level of deformation DLT(2)5 % ≤5 UNI EN 1605
Resistance to compression after 50 years of crushing ≤ 2 % CC(2/1.5/50) Kpa 130 UNI EN 1606
Long-term waterabsorption for diffusion WD(V)5 Vol. -% 2-4 UNI EN 12086
Water vapourdiffusion resistance MU µ 150 UNI EN 12088
Thermal conductivity λD 0.034-0.036* UNI EN 13164
Fire performance E UNI EN 13501/1
Thermal ability J/kgK 1260
*Dependent on thickness
49
TECHNICAL CHARACTERISTICSGESS FON RC® is a sound absorbing, sound insulating panel made up of plasterboard RB 13 and a rockwool panel. Rockwool is a porous material with excellent sound absorbing properties that, combined with a certain mass, can enhance insulation against low frequency waves.Dimensions: 2000/3000X1200 mm Insulation thicknesses: 20-30-40-50
GESS FON RC
TECHNICAL SPECIFICATIONS OF RC 80 MINERAL WOOL
TECHNICAL SPECIFICATIONS OF RC 100 MINERAL WOOL
TECHNICAL SPECIFICATIONS OF RC 160 MINERAL WOOL
Description Class U.M. Value StandardNominal density (±10%) kg/m3 80-100 EN 1602 Thermal conductivity λD 0.035 EN 13162/12667
Description Class U.M. Value StandardNominal density (±10%) kg/m3 100 EN 1602 Thermal conductivity λD 0.035 EN 13162/12667
Description Class U.M. Value StandardNominal density (±10%) kg/m3 160 EN 1602 Thermal conductivity λD 0.039 EN 13162/12667
GREEN BUILdING
50
GESS FON SUGHERO
DESCRIPTIONGESS FON SUGHERO® is a sound absorbing, sound insulating panel made up of a plasterboard RB 13 panel and a light cork panel.Dimensions: 2000/3000X1200 mmSOUND PROOFING:
dB=20-35 (500 Hz)**DEPENDENT ON THICKNESS
NATURAL LIGHT CORKDescription U.M. value standard
Nominal density (±10%) kg/m3 130 EN 1602
Thermal conductivity λD W/mK 0.043
Transpirability to water vapour µ 10-13
Putrescibility none
GREEN BUILdING
51
GESS FON 0.023
TECHNICAL CHARACTERISTICSGESS FON 0.023® is a sound absorbing, sound insulating panel made up of a plasterboard RB 13 panel and an expanded polyurethane panel according to Standard UNI EN 13165.Dimensions: 1200X2000 mm Insulation thicknesses: 30-40-50-60-80
EXPANDED POLYURETHANE 0.023 PROPERTIES
Thermal Insulation
Euroclass F
E
1453
20 30 40 50 60 70 80 90 100 120
0.022
0.023
1.15 0.77
0.87 1.30 1.74 2.17 2.61 3.04 3.48 3.91 4.35 5.22
0.58 0.46 0.38 0.33 0.29 0.26 0.23 0.19
Euroclass
Cp(J/kg K)
foam
Properties(Standard) Description
Symbol(Unit of
measurement)
ValueSome properties vary based upon the thickness (mm)
λ90/90.l
(W/mK)
UD(W/m2 K)
RD(m2 K/W)
λD(W/mK)
Value established at anaverage temperature of 10°C
Value established at anaverage temperature of 10°C
UD=λD/d
RD= d /λD
Initial average thermal conductivity(EN 12667)
Stated Thermal Conductivity
(UNI EN 13165Annexes A and C)
Stated Thermal Transmittance
Stated Thermal Resistance
Euroclass Fire performance(EN 13501-1)(EN 11925-2)(13823 (SBI))
Euroclass Fire performance(EN 11925-2)
Specific Heat
52
DESCRIPTION“Dekorsystem” is made up of a shaped EPS (sintered expanded polystyrene) element which is shaped according to requests, smoothed on the visible side using a cementitious plaster. The smoothed visible side (just like composite materials) is used to ensure the end product is resistant to external agents, knocks, bumps and has a surface ready to be treated with the classic outdoor paints. “Dekorsystem” can be used for the following: •Eave frames.•Circular frames.•String-courses.•All arch, barrel vault or cross-vault shapes.•All decorative column shapes.
dEKORSYSTEM
53
FORMSYSTEM
DESCRIPTION“Formsystem CLS”, EPS formworks, coated to achieve holes when working with concrete. The EPS formwork, coated in negative Formsystem enables the achievement of concrete pieces:- eave frames - circular frames - string courses - all arch, barrel vault or cross-vault shapes - all column shapes.The versatility of FORMSYSTEM fully satisfies design requests and requirements, in addition to facilitating the carpentry work.The installation of Formsystem CLS is carried out using traditional timbering seeing as though the formwork external surfaces are level and perpendicular.
54
Copper gauge piece Glue in powder format Wool triangles for bitumi-nous membrane returns
ACCESSORIES
Turboair roof tiles and curved tiles
Manual hammer tacker
Bird screen
Vapour barrier 120Transpiring frame 160Transpiring frame 230
Stainless steel curved tile stop hook
Zinc-coated plate washersBR dowel and wood screws
Complete attachment for corrugated roofs
Automatic hammer tacker
Adhesive sheath
Zinc-coated plate nail and dowel
55
TERMOSYSTEM ONDA
TERMOSYSTEM GRECA
PROdUCT APPLICATION
Mechanical butterfly fixing with zinc-plated corner
Mechanical fixing
Bituminous membrane layer
Bituminous membrane layer
Detail of mechanical fixing
Detail of mechanical fixing
Overlapping selvage
Overlapping selvage
Bituminous membrane
Mechanical fixing
Corrugated metal sheet.
TERMOSYSTEM GRECA
Bituminous membrane
Mechanical butterfly fixing
Zinc-plated corner for closing the eave side Cement fibre roof
56
PROdUCT APPLICATION
side view
1
23 45
6
7
1_ Eave rail2_ Bird screen3_ Eave4_ ISOVENT TOP5_ Attachment of panels using a
mechanical system6_ Waterproofing with bituminous
sheath7_ Roof mantle
1
23
456
7
81_ Eave rail2_ Bird screen3_ Eave4_ Transpiring frame5_ ISOVENT/ISOVENT TERMO
ACUSTIC/ISOVENT COMPOSITO6_ Attachment of panels using a
mechanical system7_ Waterproofing with bituminous
sheath8_ Roof mantle
ISOVENT TOP
ISOVENT/ISOVENT TERMO ACUSTIC/ISOVENT COMPOSITO
57
PROdUCT APPLICATION
1
2
3
4
5
1_ The gutter and bird screen are attached to the rail.
2_ Proceed with laying the ISOSANDWICH and ISOSANDWICH - TOP panels positioning them with the ends on the purlin centre to centre distances.
3_ Proceed with attachment of the panels using mechanical systems.
4_ Waterproofing of the upper part is achieved using transpiring film, to guarantee complete protection from accidental infiltration of the roof mantle.
5_ The roof is completed with the laying of the cotto tile roof mantle
Detail of panel M/F joint.Details of attachment of eave and bird screen to rail.
Detail of sheet attachment. Detail of inside view.
ISOSANDWICH TOP
58
Rapid mechanical fixing
8-10 cm overlapping selvage
PROdUCT APPLICATION
TERMOSYSTEM
59
Assistance for the designer and the energy certificate issuer_current standards and decrees in force_products and accessories_technical information_laboratory certifications_application solutions_thermal and sound stratigraphy_installation systems_innovative designs and solutions_technical consultancy and assistance for the installer and manufacturer_technical specifications and safety_flow rate models_expertise and promptness of response
DESIGN ASSISTANCE
To discover the advantages Isosystem research offers to those who believe both in the building concept and respect for the environment, privately and publicly, every year, a significant budget amount is allocated to communications. The Isosystem brand and products regularly appear in sector publications. Catalogues with CD ROMs, periodically updated, illustrate every detail of materials and their applications. Participation in national and international fairs, the organisation of elaboration and exchange meetings complete the range of Isosystem marketing actions in the interest of company-customer/customer-company relationships and information.
COMMUNICATIONS