Page 1: The REAL Mini Implant - ULTIMATICSMini implant surgical protocol does not require an osteotomy site, just a pilot hole through the cortical bone. Therefore, the implant must be able

IMMEDIATE

SIMPLIFIED

STABILIZE

PROVISIONAL

DIRECT

by INTRA-LOCK®

IMMEDIATELOAD

SIMPLIFIED PROCEDURE

STABILIZEDENTURES

PROVISIONALPROSTHETICS

DIRECTPLACEMENT

The REAL Mini ImplantThe REAL Mini Implant

Page 2: The REAL Mini Implant - ULTIMATICSMini implant surgical protocol does not require an osteotomy site, just a pilot hole through the cortical bone. Therefore, the implant must be able

ENGINEERED EVOLUTION.

Polished Collar

SharpApical

GuidingPoint

Mini Drive-Lock™ Surgical Placement SystemMini Drive-Lock™ Surgical Placement System

• Ease of Delivery and Insertion• DIRECT DELIVERY PACKAGE • INSTRUMENTATION FOR LINEAR PATH OF INSERTION

MDL Implants were designed to take advantage of the Drive-Lock™ System which ensures ContraAngle delivery and placement is fluid, economic in motion and predictable. It allows the MDL implantto be removed from its sterile vial, transferred directly to the surgical site and to initiate the self- tappingaction. A Drive-Lock™ Adapter mates with a surgical ratchet wrench for final seating. This ratchet adaptercan be used by hand and also mates with an optional Round Hand Driver to provide greater initialtorque and enhanced tactile sensation. All Drive-Lock™ instruments are designed to promote a linear path of insertion.

• Maximum Self-Threading Capabilities• SHARP APICAL GUIDING POINT • OPTIMUM THREAD PITCH • PROFILED FOR STABILITY • ENGINEERED FOR STRENGTH

MDL’s sharp apical guiding point initiates the self-tapping process, even in the densest bone. Unlikeconventional sized implants, mini implants rely on the viscoelastic nature of bone tissue. They functionvery much like orthopedic fixation screws. Mini implant surgical protocol does not require anosteotomy site, just a pilot hole through the cortical bone. Therefore, the implant must be able topenetrate the cortical plate, cut its way through the alveolar bone with maximum ease and efficiency,forcibly wedging itself into place. Its thread pitch and wedge profile permits intimate contact betweenthe bone and implant surface ensuring initial stability and encouraging immediate load success. MDL’s profile is also configured to provide maximum strength where the highest forces are generated.

• Soft Tissue and Prosthetic Interface• POLISHED COLLAR • ACHIEVES OPTIMUM IMPLANT DEPTH

MDL Implants are designed with a polished collar in order to optimize the soft tissue response to theimplant surface. All Drive-Lock™ instrumentation seats over the O-Ball abutment precisely mating withthe top of the collar. This ensures that depth of implant placement is accurately attained when theshoulder of the collar is flush with (the height of) the surrounding gingiva. MDL’s are provided with O-Rings encased in Metal Housings ready to be processed in a denture. A special abutment thatcements over the O-Ball assembly has been designed for temporary fixed bridges. This abutmentfunctions as an impression coping and can be laboratory machined for parallelism.

Intra-Lock™ has elevated the engineering and delivery system of the Mini Dental Implant.

Self-Limiting Depth Design

Profiled for Strengthand Stability

Optimum Thread Pitch and Surface Finish

(Patent Pending)

Page 3: The REAL Mini Implant - ULTIMATICSMini implant surgical protocol does not require an osteotomy site, just a pilot hole through the cortical bone. Therefore, the implant must be able

Ligh

t, r

epea

ted,

inte

rmed

iate

, ver

tica

l in

tro

duct

ion

of

the

1.2m

m e

xter

nal

ly ir

riga

ted

Pil

ot D

rill

bre

ach

es

the

gin

giva

l ti

ssu

e an

d pe

rio

steu

m.

MD

L’s

are

rem

ove

d fr

om

th

eir

ster

ile

vial

an

d tr

ansf

erre

d di

rect

ly t

o t

he

surg

ical

sit

e vi

a a

Dri

ve-L

ock

Co

ntr

a-A

ngl

e At

tach

men

t th

at s

nap

s o

ver

the

O-b

all

asse

mbl

y.

The

use

of

an e

lect

ric

mot

or

wit

h a

torq

ue

lim

itin

g fe

atu

re s

et t

o 3

5Ncm

is r

eco

mm

ende

d.

MD

L’s

shar

p ap

ical

gli

din

gpo

int

init

iate

s th

e se

lf-

tapp

ing

acti

on

; th

read

ing

and

expa

ndi

ng

the

bon

e at

th

esa

me

tim

e. In

pre

para

tio

n f

or

the

fin

al s

eati

ng,

Th

eh

andp

iece

wil

l st

all

wh

en t

he

torq

ue

lim

itin

g va

lue

of

35N

cm is

rea

ched

.

Dri

llin

g de

pth

isap

prox

imat

ely

on

e-th

ird

the

len

gth

of

the

impl

ant

wit

hca

re t

aken

to

bre

ach

th

eco

rtic

al p

late

.

MD

L Im

plan

t D

entu

re S

tabi

lizat

ion

Page 4: The REAL Mini Implant - ULTIMATICSMini implant surgical protocol does not require an osteotomy site, just a pilot hole through the cortical bone. Therefore, the implant must be able

Dri

ve-L

ock

Ada

pter

mat

es w

ith

a S

urg

ical

Rat

chet

Wre

nch

fo

r th

e fi

nal

sea

tin

g ph

ase.

Th

is R

atch

et A

dapt

er

can

be

use

d by

han

d an

d al

so m

ates

wit

h a

n o

ptio

nal

R

ou

nd

Han

d D

rive

r to

pro

vide

gre

ater

init

ial

torq

ue

and

enh

ance

d ta

ctil

e se

nsa

tio

n.

Sm

all

incr

emen

tal

turn

s, w

ith

a p

ause

bet

wee

nea

ch t

urn

to

tak

e ad

van

tage

of

the

visc

oel

asti

cn

atu

re o

f th

e bo

ne

acco

mpl

ish

es f

inal

sea

tin

g.Th

e co

rrec

t de

pth

of

an M

DL

impl

ant

isac

hie

ved

wh

en t

he

wre

nch

ada

pter

is f

lush

wit

h t

he

surr

ou

ndi

ng

gin

giva

l ti

ssu

e.

They

sn

ap o

ver

th

e O

-Bal

las

sem

bly

read

y to

be

pro

cess

edin

a d

entu

re. A

spe

cial

abu

tmen

tth

at c

emen

ts o

ver

the

O-B

all

asse

mbl

y h

as b

een

des

ign

ed f

or

tem

pora

ry f

ixed

bri

dges

MD

L’s

are

pro

vide

d w

ith

O-R

ings

en

case

d in

Met

al H

ou

sin

gs.

Page 5: The REAL Mini Implant - ULTIMATICSMini implant surgical protocol does not require an osteotomy site, just a pilot hole through the cortical bone. Therefore, the implant must be able

MDL Temporary Abutment Protocol

1. Surgical Placement - MDL Implants aresurgically placed in position.

2. Impression Copings - MDL Abutments slideover O-Balls and serve as impression copings.

3. Impression - MDL Abutments are picked up inan impression tray.

4. MDL Analogs - Analogs are placed into theMDL Abutments in the impression.

5. MDL Abutment Preparation - A laboratorymilling machine prepares the abutments toachieve parallelism.

6. Temporary Fixed Bridges -The Abutments arecemented over the MDL Implants with resincement. A metal reinforced bridge (for rigidity)is then cemented on the abutments withtemporary cement.

Surgical PlacementSurgical Placement Impression CopingsImpression Copings

ImpressionImpression MDL AnalogsMDL Analogs

MDL Abutment PreparationMDL Abutment Preparation Temporary Fixed BridgesTemporary Fixed Bridges

3

1

5

2

4

6

Page 6: The REAL Mini Implant - ULTIMATICSMini implant surgical protocol does not require an osteotomy site, just a pilot hole through the cortical bone. Therefore, the implant must be able

IMPLANTS

DRILL

INSTRUMENTS FOR INSERTION OF IMPLANTS

SURGICAL BOX

PROSTHETIC COMPONENTS

Intra-Lock International, Inc.1200 North Federal Highway, Suite 200Boca Raton, Florida 33432www.intra-lock.com • [email protected]

0499 • © Copyright 2003, Intra-Lock® System International • S4EN-09-01

MDI™ Mini Drive-Lock implants, 2.0mm Diameter

Length 10mm 13mm 15mm 18mmRef No. MDL10 MDL13 MDL15 MDL18

Mini Drive-Lock Pilot Twist Drill

1.2mm diameter..........................................................................MDLPD

Mini Drive-Lock Contra Angle Driver

Standard Contra Angle..............................................................MDLCAD

Mini Drive-Lock Ratchet Driver

Use as an MDL Hand Driver or with a Surgical Ratchet Wrench ............................................................MDLRD

Mini Drive-Lock Manual Wrench

Connects to Mini Drive-Lock Ratchet Driver ............................MDLMW

Surgical Ratchet Wrench

With square connection, 4x4mm, autoclavable ..................................SR

Mini Drive-Lock Surgical Box

Accommodates all MDL surgical instrumentsfor MDL Implant delivery and placement ....................................MDLSK

Mini Drive-Lock Laboratory Analog

Replicates the MDL Implant and abutment..................................MDLLA

Mini Drive-Lock Metal Housings with O-Rings

O-Rings encapsulated in metal housings for ease of placement andreplacement ..............................................................................MDLMH

MDL O-Ring Replacements

Quantity of 10 ............................................................................MDLOR

Mini Drive-Lock Cementable Abutment

Cements over O-Ball assembly for temporary fixed bridges ........MDLSA

MDLCAD

MDLMW

MDLRD

SR

MDLLA

MDLMH

MDLSA

MDLOR

CE