The Original Gold Standard Framing Coil - AngioCalc · 2020. 10. 4. · 1 1. 2 5 i n 1 . 1. 2 5 i...

8
The Original Gold Standard Framing Coil The MICRUSPHERE ® Microcoil is a spherical coil designed to provide a stable, predictable frame and conform to a myriad of aneurysm shapes. Unique Micrus ® Loop Deployment • Coil loops deploy in a 90° fashion, providing structure and stability to aneurysm dome and walls • Enhanced neck coverage • Anatomically compliant to the shape of each individual aneurysm Balancing Stability with Softness • Bench studies confirm that the MICRUSPHERE Microcoil is softer than the Boston Scientific GDC ® 360° Soft SR and Standard Coils Less Soft More Soft Relative Softness Comparison (As Measured by Spring Constant Bench Testing) Boston Scientific GDC 360° Standard † Data on file, Micrus Endovascular Corporation MICRUSPHERE Microcoil Boston Scientific GDC 360° Soft SR Coil MICRUSPHERE ® Microcoils

Transcript of The Original Gold Standard Framing Coil - AngioCalc · 2020. 10. 4. · 1 1. 2 5 i n 1 . 1. 2 5 i...

Page 1: The Original Gold Standard Framing Coil - AngioCalc · 2020. 10. 4. · 1 1. 2 5 i n 1 . 1. 2 5 i n. 8. 8 1 2 5 i n. 0. 2 1 8 7 5 i n. 0. 7 5 i n. 0. 2 1 8 7 5 i n. 0. 7 5 i n. 0.

The Original Gold Standard Framing CoilThe MICRUSPHERE® Microcoil is a spherical coil designed to provide a stable,

predictable frame and conform to a myriad of aneurysm shapes.

Unique Micrus® Loop Deployment • Coil loops deploy in a 90° fashion, providing structure and stability

to aneurysm dome and walls

• Enhanced neck coverage

• Anatomically compliant to the shape of each individual aneurysm

Balancing Stability with Softness • Bench studies confirm that the MICRUSPHERE Microcoil is softer

than the Boston Scientific GDC® 360° Soft SR and Standard Coils

Less Soft

More Soft

Relative Softness Comparison(As Measured by Spring Constant Bench Testing)†

Boston Scientific GDC 360°Standard

† Data on file, Micrus Endovascular Corporation

MICRUSPHEREMicrocoil

Boston Scientific GDC 360° Soft

SR Coil

MICRUSPHERE® Microcoils

Page 2: The Original Gold Standard Framing Coil - AngioCalc · 2020. 10. 4. · 1 1. 2 5 i n 1 . 1. 2 5 i n. 8. 8 1 2 5 i n. 0. 2 1 8 7 5 i n. 0. 7 5 i n. 0. 2 1 8 7 5 i n. 0. 7 5 i n. 0.

P/N 50944-01 REV B

www.micruscorp.comCAUTION: Federal (U.S.A.) law restricts this device to sale by or on the order of a physician.MICRUS, MICRUS ENDOVASCULAR, MICRUSPHERE, CERECYTE, and the M logo are registered trademarks of Micrus Endovascular Corporation.IT’S INSIDE and the purple coil logo are trademarks of Micrus Endovascular Corporation. GDC is a registered trademark of Boston Scientific Corporation. © 2008 Micrus Endovascular Corporation. All rights reserved.

821 Fox LaneSan Jose, CA 95131United StatesT 408.433.1400F 408.433.1401

Avenue des Baumettes 71020 RenensSwitzerlandT +41.21.631.3434F +41.21.631.3444

1st Floor, Unit 4Stansted CourtyardTakeleyBishop’s StortfordEssexCM22 6PUUnited KingdomT +44.800.612.6363F +44.800.612.8484

PLATINUM® MICROCOILS

CATALOG NUMBER SPHERICAL LOOP DIAMETER OVERALL LENGTH

10

SPH100200-20 2 mm 2.5 cm SPH100250-20 2.5 mm 3.3 cm SPH100300-20 3 mm 5.4 cm SPH100350-20 3.5 mm 6.6 cm SPH100400-20 4 mm 7.5 cm SPH100500-20 5 mm 9.7 cm SPH100600-20 6 mm 11.9 cm SPH100620-20 6 mm 20 cm SPH100700-20 7 mm 13.9 cm SPH100720-20 7 mm 20 cm SPH100800-20 8 mm 16.1 cm SPH100825-20 8 mm 25 cm SPH100900-20 9 mm 18.4 cm SPH100925-20 9 mm 25 cm SPH101000-20 10 mm 20.3 cm SPH101030-20 10 mm 30 cm

SPH180200-20 2 mm 2.7 cm SPH180300-20 3 mm 5.8 cm SPH180400-20 4 mm 7.9 cm SPH180500-20 5 mm 10 cm SPH180600-20 6 mm 12.2 cm SPH180700-20 7 mm 14.3 cm SPH180800-20 8 mm 13.6 cm SPH180900-20 9 mm 15.3 cm SPH181000-20 10 mm 17.1 cm SPH181100-20 11 mm 18.9 cm SPH181200-20 12 mm 20.7 cm SPH181300-20 13 mm 22.6 cm SPH181400-20 14 mm 24.3 cm SPH181500-20 15 mm 26 cm SPH181600-20 16 mm 27.9 cm SPH181700-20 17 mm 30 cm SPH181800-20 18 mm 30 cm

SPHERICAL (SPH10)

CATALOG NUMBER SPHERICAL LOOP DIAMETER OVERALL LENGTH

18 SPHERICAL (SPH18)

CERECYTE® MICROCOILS

CATALOG NUMBER SPHERICAL LOOP DIAMETER OVERALL LENGTH

10

CSP100200-30 2 mm 2.5 cm CSP100250-30 2.5 mm 3.3 cm CSP100300-30 3 mm 5.4 cm CSP100350-30 3.5 mm 6.6 cm CSP100400-30 4 mm 7.5 cm CSP100500-30 5 mm 9.7 cm CSP100600-30 6 mm 11.9 cm CSP100700-30 7 mm 13.9 cm CSP100800-30 8 mm 16.1 cm CSP100900-30 9 mm 18.4 cm CSP101000-30 10 mm 20.3 cm

SPHERICAL (CSP10)

CSP180200-30 2 mm 2.7 cm CSP180300-30 3 mm 5.8 cm CSP180400-30 4 mm 7.9 cm CSP180500-30 5 mm 10 cm CSP180600-30 6 mm 12.2 cm CSP180700-30 7 mm 14.3 cm CSP180800-30 8 mm 13.6 cm CSP180900-30 9 mm 15.3 cm CSP181000-30 10 mm 17.1 cm CSP181100-30 11 mm 18.9 cm CSP181200-30 12 mm 20.7 cm CSP181300-30 13 mm 22.6 cm CSP181400-30 14 mm 24.3 cm CSP181500-30 15 mm 26 cm CSP181600-30 16 mm 27.9 cm CSP181700-30 17 mm 30 cm CSP181800-30 18 mm 30 cm

CATALOG NUMBER SPHERICAL LOOP DIAMETER OVERALL LENGTH

18 SPHERICAL (CSP18)

RECOMMENDED MICROCATHETER ID: 0.014˝– 0.017˝

RECOMMENDED MICROCATHETER ID: 0.017˝– 0.021˝

RECOMMENDED MICROCATHETER ID: 0.014˝– 0.017˝

RECOMMENDED MICROCATHETER ID: 0.017˝– 0.021˝

Page 3: The Original Gold Standard Framing Coil - AngioCalc · 2020. 10. 4. · 1 1. 2 5 i n 1 . 1. 2 5 i n. 8. 8 1 2 5 i n. 0. 2 1 8 7 5 i n. 0. 7 5 i n. 0. 2 1 8 7 5 i n. 0. 7 5 i n. 0.

Start with StabilityMicrus Microcoils provide a stable, predictable frame while leaving an open inner core ready for yournext coil. This makes them an ideal choice for the RUSSIAN DOLL technique. Here’s why.

One Loop at a TimeMicrus coils deploy outward, one loop at a time, toward the aneurysm walls. This allows theentire coil to conform to the shape of each individual aneurysm, while providing a predictable frame.

Loops deploy outward ina complete circle towardaneurysm periphery

Each loop abuts the prior loop Bearing an open core

Most loops deploy in“horseshoe-shaped”increments

“Horseshoe” loops bend morefreely and may provide lessstructure

And create multiplecompartments

MICRUSPHERE Microcoil 8 mm x 13.6 cm

Designed to provideenhanced stability

Segments cross throughcenter core

Competitive microcoil 8 mm x 20 cm

Micrus® Microcoils:

MICRUSPHERE® Microcoil

PRESIDIO® Microcoil

CASHMERE™ Microcoil

ULTIPAQ® Microcoil

HELIPAQ® Microcoil

INTERPAQ® Microcoil

Accessories:

EnPower™ Detachment Control Box

Detachment Control Box

Connecting Cable

www.micruscorp.com

CAUTION: Federal (U.S.A.) law restricts this device to sale by or on the order of a physician.MICRUS, MICRUS ENDOVASCULAR, PRESIDIO, MICRUSPHERE, ULTIPAQ, HELIPAQ, INTERPAQ, and the M logo are registered trademarks of Micrus Endovascular Corporation.Russian Doll, frilling, CASHMERE, and EnPower are trademarks of Micrus Endovascular Corporation.© 2008 Micrus Endovascular Corporation. All rights reserved.

Avenue des Baumettes 71020 RenensSwitzerland

T +41.21.631.3434F +41.21.631.3444

821 Fox LaneSan Jose, CA 95131United States

T 408.433.1400F 408.433.1401

1st Floor, Unit 4Stansted CourtyardTakeleyBishop’s StortfordEssexCM22 6PUUnited Kingdom

T +44.800.612.6363F +44.800.612.8484

P/N 50981-01 REV A

REFERENCES:1. Piotin M, Iijima A, Wada H, Moret J. Increasing the packing of small aneurysms with complex-shaped coils: an in vitro study.

AJNR Am J Neuroradiol. 2003;24:1446-1448.2. Wakhloo AK, Gounis MJ, Sandhu JS, Akkawi N, Schenck AE, Linfante I. Complex-shaped platinum coils for brain aneurysms: higherpacking density, improved biomechanical stability, and midterm angiographic outcome. AJNR Am J Neuroradiol. 2007;28:1395-1400.

3. Vallee JN, Pierot L, Bonafe A, et al. Endovascular treatment of intracranial wide-necked aneurysms using three-dimensional coils:predictors of immediate anatomic and clinical results. AJNR Am J Neuroradiol. 2004;25;298-306.

4. Gonzalez N, Murayama Y, Nien YL, et al. Treatment of unruptured aneurysms with GDCs: clinical experience with 247 aneurysms.AJNR Am J Neuroradiol. 2004;25:577-583.

S T R E N G T H T A K E S S H A P E

M I C R U S M I C R O C O I L S

OptimizeNeckCoverage

ImprovedneckprotectionwiththePRESIDIOMicrocoil

TheanatomicallycompliantframeandhighshapememoryofMicrusMicrocoilsaredesignedtoimproveneckcoverageandprovide:

•Stablescaffoldingthatcoverstheneck

•Fillingofopenspaces,especiallyinregionofaneurysmalneck

•Littleriskofcoilprotrusionthroughtheneck,eveninwidenecks

•Littleriskofframedeformation3

NeckcoverageisoptimizedwiththePRESIDIOMicrocoil,especiallywhenusedintheRussianDolltechnique.Thecoilisastableframeandanexcellentfillingcoil,whichhasenabledustocoilmanywide-neckedaneurysmswithouttheneedforastent.

AveryEvans,MD,UniversityofVirginia

Neckremnantsobservedangiographicallyaftercoilingtripletheriskofcompactionandrecanalization.4

8.75 in.8.71875 in.

8.71875 in.

0.21875 in.

8.75 in.

11.25in.11

.25

in.

8.81

25in

.

0.21

875

in.

0.75

in.

0.21

875

in.

0.75

in.

0.25

in.

0.25

in.

07-MIC-030 MICRUS MICROCOIL FAMILY BROCHURE BLACK CYAN MAGENTA YELLOW PMS877 DIELINE

BLACK CYAN MAGENTA YELLOW PMS 877

OUTSIDE

Page 4: The Original Gold Standard Framing Coil - AngioCalc · 2020. 10. 4. · 1 1. 2 5 i n 1 . 1. 2 5 i n. 8. 8 1 2 5 i n. 0. 2 1 8 7 5 i n. 0. 7 5 i n. 0. 2 1 8 7 5 i n. 0. 7 5 i n. 0.

Start with StabilityMicrus Microcoils provide a stable, predictable frame while leaving an open inner core ready for yournext coil. This makes them an ideal choice for the RUSSIAN DOLL technique. Here’s why.

One Loop at a TimeMicrus coils deploy outward, one loop at a time, toward the aneurysm walls. This allows theentire coil to conform to the shape of each individual aneurysm, while providing a predictable frame.

Loops deploy outward ina complete circle towardaneurysm periphery

Each loop abuts the prior loop Bearing an open core

Most loops deploy in“horseshoe-shaped”increments

“Horseshoe” loops bend morefreely and may provide lessstructure

And create multiplecompartments

MICRUSPHERE Microcoil 8 mm x 13.6 cm

Designed to provideenhanced stability

Segments cross throughcenter core

Competitive microcoil 8 mm x 20 cm

Micrus® Microcoils:

MICRUSPHERE® Microcoil

PRESIDIO® Microcoil

CASHMERE™ Microcoil

ULTIPAQ® Microcoil

HELIPAQ® Microcoil

INTERPAQ® Microcoil

Accessories:

EnPower™ Detachment Control Box

Detachment Control Box

Connecting Cable

www.micruscorp.com

CAUTION: Federal (U.S.A.) law restricts this device to sale by or on the order of a physician.MICRUS, MICRUS ENDOVASCULAR, PRESIDIO, MICRUSPHERE, ULTIPAQ, HELIPAQ, INTERPAQ, and the M logo are registered trademarks of Micrus Endovascular Corporation.Russian Doll, frilling, CASHMERE, and EnPower are trademarks of Micrus Endovascular Corporation.© 2008 Micrus Endovascular Corporation. All rights reserved.

Avenue des Baumettes 71020 RenensSwitzerland

T +41.21.631.3434F +41.21.631.3444

821 Fox LaneSan Jose, CA 95131United States

T 408.433.1400F 408.433.1401

1st Floor, Unit 4Stansted CourtyardTakeleyBishop’s StortfordEssexCM22 6PUUnited Kingdom

T +44.800.612.6363F +44.800.612.8484

P/N 50981-01 REV A

REFERENCES:1. Piotin M, Iijima A, Wada H, Moret J. Increasing the packing of small aneurysms with complex-shaped coils: an in vitro study.

AJNR Am J Neuroradiol. 2003;24:1446-1448.2. Wakhloo AK, Gounis MJ, Sandhu JS, Akkawi N, Schenck AE, Linfante I. Complex-shaped platinum coils for brain aneurysms: higherpacking density, improved biomechanical stability, and midterm angiographic outcome. AJNR Am J Neuroradiol. 2007;28:1395-1400.

3. Vallee JN, Pierot L, Bonafe A, et al. Endovascular treatment of intracranial wide-necked aneurysms using three-dimensional coils:predictors of immediate anatomic and clinical results. AJNR Am J Neuroradiol. 2004;25;298-306.

4. Gonzalez N, Murayama Y, Nien YL, et al. Treatment of unruptured aneurysms with GDCs: clinical experience with 247 aneurysms.AJNR Am J Neuroradiol. 2004;25:577-583.

S T R E N G T H T A K E S S H A P E

M I C R U S M I C R O C O I L S

OptimizeNeckCoverage

ImprovedneckprotectionwiththePRESIDIOMicrocoil

TheanatomicallycompliantframeandhighshapememoryofMicrusMicrocoilsaredesignedtoimproveneckcoverageandprovide:

•Stablescaffoldingthatcoverstheneck

•Fillingofopenspaces,especiallyinregionofaneurysmalneck

•Littleriskofcoilprotrusionthroughtheneck,eveninwidenecks

•Littleriskofframedeformation3

NeckcoverageisoptimizedwiththePRESIDIOMicrocoil,especiallywhenusedintheRussianDolltechnique.Thecoilisastableframeandanexcellentfillingcoil,whichhasenabledustocoilmanywide-neckedaneurysmswithouttheneedforastent.

AveryEvans,MD,UniversityofVirginia

Neckremnantsobservedangiographicallyaftercoilingtripletheriskofcompactionandrecanalization.4

8.75 in.8.71875 in.

8.71875 in.

0.21875 in.

8.75 in.

11.25in.11

.25

in.

8.81

25in

.

0.21

875

in.

0.75

in.

0.21

875

in.

0.75

in.

0.25

in.

0.25

in.

07-MIC-030 MICRUS MICROCOIL FAMILY BROCHURE BLACK CYAN MAGENTA YELLOW PMS877 DIELINE

BLACK CYAN MAGENTA YELLOW PMS 877

OUTSIDE

Page 5: The Original Gold Standard Framing Coil - AngioCalc · 2020. 10. 4. · 1 1. 2 5 i n 1 . 1. 2 5 i n. 8. 8 1 2 5 i n. 0. 2 1 8 7 5 i n. 0. 7 5 i n. 0. 2 1 8 7 5 i n. 0. 7 5 i n. 0.

The fast anddense FRILLING™ coil

The soft, conformable14 System coil

The original “gold standard” coilin framing and stability

Shape MattersFrom the precise placement of your first microcoil to the last finishing coil, shape matters. In fact,studies have shown the clinical benefits of using spherical or complex-shaped coils in a concentricfashion1–3 —known as the RUSSIAN DOLL™ Coiling technique.

Micrus® MicrocoilsMicrus Microcoils have a unique shape technology designed to enhance the benefits ofRUSSIAN DOLL Coiling: stability, neck coverage, and dense packing.

Open CoreThe outward deployment of Micrus Microcoils minimizes "section" or "segment" coiling, potentiallyreducing compaction, and limits loops from random herniation into the parent vessel.

Loops deploy to periphery Stable scaffolding limits loopherniation into parent vessel

PRESIDIO® MICROCOIL10 SYSTEM8 mm x 29 cm

CASHMERE™ MICROCOIL14 SYSTEM9 mm x 22 cm

Two microcoils with core open foradditional packing

MICRUSPHERE® MICROCOILS10 SYSTEM

Maximize Packing DensityStudies suggest that greater packing volumes and improved filling may be achieved with the RUSSIAN DOLLcoiling technique.1–3

Micrus bench studies have also confirmed that higher packing densities can be achieved when Micrus coilsare packed using the RUSSIAN DOLL technique. This may lead to less compartmentalization and compaction.

The use of three-dimensional Micrus coils proved to be useful for improving the coil packing andangiographic and volumic occlusion of aneurysms…at the time of treatment, provided...the largestnumber of three-dimensional coils were first positioned.3

RUSSIAN DOLLPacking

2-D Packing

P-Value = .036

Micrus Microcoil Packing Density*12.5% Relative Increase

Pack

ing

Dens

ity(%

)

*Data on file, Micrus Endovascular Corporation.

8.75 in. 8.71875 in.

8.71875 in.

0.21875 in.

8.75 in.

11.2

5in

.

11.2

5in

.

8.81

25in

.

0.21

875

in.

0.75

in.

0.21

875

in.

0.75

in.

NON

GLUE

AREA

NON

GLUE

AREA

0.25

in.

07-MIC-030 MICRUS MICROCOIL FAMILY BROCHURE BLACK CYAN MAGENTA YELLOW PMS877 DIELINE

BLACK CYAN MAGENTA YELLOW PMS 877

INSIDE

Page 6: The Original Gold Standard Framing Coil - AngioCalc · 2020. 10. 4. · 1 1. 2 5 i n 1 . 1. 2 5 i n. 8. 8 1 2 5 i n. 0. 2 1 8 7 5 i n. 0. 7 5 i n. 0. 2 1 8 7 5 i n. 0. 7 5 i n. 0.

The fast anddense FRILLING™ coil

The soft, conformable14 System coil

The original “gold standard” coilin framing and stability

Shape MattersFrom the precise placement of your first microcoil to the last finishing coil, shape matters. In fact,studies have shown the clinical benefits of using spherical or complex-shaped coils in a concentricfashion1–3—known as the RUSSIAN DOLL™ Coiling technique.

Micrus® MicrocoilsMicrus Microcoils have a unique shape technology designed to enhance the benefits ofRUSSIAN DOLL Coiling: stability, neck coverage, and dense packing.

Open CoreThe outward deployment of Micrus Microcoils minimizes "section" or "segment" coiling, potentiallyreducing compaction, and limits loops from random herniation into the parent vessel.

Loops deploy to periphery Stable scaffolding limits loopherniation into parent vessel

PRESIDIO® MICROCOIL10 SYSTEM8 mm x 29 cm

CASHMERE™ MICROCOIL14 SYSTEM9 mm x 22 cm

Two microcoils with core open foradditional packing

MICRUSPHERE® MICROCOILS10 SYSTEM

Maximize Packing DensityStudies suggest that greater packing volumes and improved filling may be achieved with the RUSSIAN DOLLcoiling technique.1–3

Micrus bench studies have also confirmed that higher packing densities can be achieved when Micrus coilsare packed using the RUSSIAN DOLL technique. This may lead to less compartmentalization and compaction.

The use of three-dimensional Micrus coils proved to be useful for improving the coil packing andangiographic and volumic occlusion of aneurysms…at the time of treatment, provided...the largest

number of three-dimensional coils were first positioned.3

RUSSIAN DOLLPacking

2-D Packing

P-Value = .036

Micrus Microcoil Packing Density*12.5% Relative Increase

PackingDensity

(%)

*Data on file, Micrus Endovascular Corporation.

8.75 in. 8.71875 in.

8.71875 in.

0.21875 in.

8.75 in.

11.2

5in

.

11.2

5in

.

8.81

25in

.

0.21

875

in.

0.75

in.

0.21

875

in.

0.75

in.

NON

GLUE

AREA

NON

GLUE

AREA

0.25

in.

07-MIC-030 MICRUS MICROCOIL FAMILY BROCHURE BLACK CYAN MAGENTA YELLOW PMS877 DIELINE

BLACK CYAN MAGENTA YELLOW PMS 877

INSIDE

Page 7: The Original Gold Standard Framing Coil - AngioCalc · 2020. 10. 4. · 1 1. 2 5 i n 1 . 1. 2 5 i n. 8. 8 1 2 5 i n. 0. 2 1 8 7 5 i n. 0. 7 5 i n. 0. 2 1 8 7 5 i n. 0. 7 5 i n. 0.

StartwithStabilityMicrusMicrocoilsprovideastable,predictableframewhileleavinganopeninnercorereadyforyournextcoil.ThismakesthemanidealchoicefortheRUSSIANDOLLtechnique.Here’swhy.

OneLoopataTimeMicruscoilsdeployoutward,oneloopatatime,towardtheaneurysmwalls.Thisallowstheentirecoiltoconformtotheshapeofeachindividualaneurysm,whileprovidingapredictableframe.

Loopsdeployoutwardinacompletecircletowardaneurysmperiphery

EachloopabutsthepriorloopBearinganopencore

Mostloopsdeployin“horseshoe-shaped”increments

“Horseshoe”loopsbendmorefreelyandmayprovidelessstructure

Andcreatemultiplecompartments

MICRUSPHEREMicrocoil8mmx13.6cm

Designedtoprovideenhancedstability

Segmentscrossthroughcentercore

Competitivemicrocoil8mmx20cm

Micrus®Microcoils:

MICRUSPHERE®Microcoil

PRESIDIO®Microcoil

CASHMERE™Microcoil

ULTIPAQ®Microcoil

HELIPAQ®Microcoil

INTERPAQ®Microcoil

Accessories:

EnPower™DetachmentControlBox

DetachmentControlBox

ConnectingCable

www.micruscorp.com

CAUTION:Federal(U.S.A.)lawrestrictsthisdevicetosalebyorontheorderofaphysician.MICRUS,MICRUSENDOVASCULAR,PRESIDIO,MICRUSPHERE,ULTIPAQ,HELIPAQ,INTERPAQ,andtheMlogoareregisteredtrademarksofMicrusEndovascularCorporation.RussianDoll,frilling,CASHMERE,andEnPoweraretrademarksofMicrusEndovascularCorporation.©2008MicrusEndovascularCorporation.Allrightsreserved.

AvenuedesBaumettes71020RenensSwitzerland

T+41.21.631.3434F+41.21.631.3444

821FoxLaneSanJose,CA95131UnitedStates

T408.433.1400F408.433.1401

1stFloor,Unit4StanstedCourtyardTakeleyBishop’sStortfordEssexCM226PUUnitedKingdom

T+44.800.612.6363F+44.800.612.8484

P/N50981-01REVA

REFERENCES:1.PiotinM,IijimaA,WadaH,MoretJ.Increasingthepackingofsmallaneurysmswithcomplex-shapedcoils:aninvitrostudy.

AJNRAmJNeuroradiol.2003;24:1446-1448.2.WakhlooAK,GounisMJ,SandhuJS,AkkawiN,SchenckAE,LinfanteI.Complex-shapedplatinumcoilsforbrainaneurysms:higherpackingdensity,improvedbiomechanicalstability,andmidtermangiographicoutcome.AJNRAmJNeuroradiol.2007;28:1395-1400.

3.ValleeJN,PierotL,BonafeA,etal.Endovasculartreatmentofintracranialwide-neckedaneurysmsusingthree-dimensionalcoils:predictorsofimmediateanatomicandclinicalresults.AJNRAmJNeuroradiol.2004;25;298-306.

4.GonzalezN,MurayamaY,NienYL,etal.TreatmentofunrupturedaneurysmswithGDCs:clinicalexperiencewith247aneurysms.AJNRAmJNeuroradiol.2004;25:577-583.

STRENGTHTAKESSHAPE

MICRUSMICROCOILS

Optimize Neck Coverage

Improved neck protectionwith the PRESIDIO Microcoil

The anatomically compliant frame and high shape memory ofMicrus Microcoils are designed to improve neck coverage and provide:

• Stable scaffolding that covers the neck

• Filling of open spaces, especially in region of aneurysmal neck

• Little risk of coil protrusion through the neck, even in wide necks

• Little risk of frame deformation3

Neck coverage is optimized with the PRESIDIOMicrocoil, especially when used in the RussianDoll technique. The coil is a stable frame andan excellent filling coil, which has enabled usto coil many wide-necked aneurysms withoutthe need for a stent.

Avery Evans, MD, University of Virginia

Neck remnants observed angiographically after coiling triple the riskof compaction and recanalization.4

8.75 in. 8.71875in.

8.71875in.

0.21875in.

8.75 in.

11.2

5in

. 11.25in.

8.8125in.

0.21875in.

0.75in.

0.21875in.

0.75in.

0.25in.

0.25in.

07-MIC-030 MICRUS MICROCOIL FAMILYBROCHURE BLACKCYAN MAGENTA YELLOWPMS877 DIELINE

BLACKCYANMAGENTAYELLOWPMS 877

OUTSIDE

Page 8: The Original Gold Standard Framing Coil - AngioCalc · 2020. 10. 4. · 1 1. 2 5 i n 1 . 1. 2 5 i n. 8. 8 1 2 5 i n. 0. 2 1 8 7 5 i n. 0. 7 5 i n. 0. 2 1 8 7 5 i n. 0. 7 5 i n. 0.

Start with StabilityMicrus Microcoils provide a stable, predictable frame while leaving an open inner core ready for yournext coil. This makes them an ideal choice for the RUSSIAN DOLL technique. Here’s why.

One Loop at a TimeMicrus coils deploy outward, one loop at a time, toward the aneurysm walls. This allows theentire coil to conform to the shape of each individual aneurysm, while providing a predictable frame.

Loops deploy outward ina complete circle towardaneurysm periphery

Each loop abuts the prior loop Bearing an open core

Most loops deploy in“horseshoe-shaped”increments

“Horseshoe” loops bend morefreely and may provide lessstructure

And create multiplecompartments

MICRUSPHERE Microcoil 8 mm x 13.6 cm

Designed to provideenhanced stability

Segments cross throughcenter core

Competitive microcoil 8 mm x 20 cm

Micrus® Microcoils:

MICRUSPHERE® Microcoil

PRESIDIO® Microcoil

CASHMERE™ Microcoil

ULTIPAQ® Microcoil

HELIPAQ® Microcoil

INTERPAQ® Microcoil

Accessories:

EnPower™ Detachment Control Box

Detachment Control Box

Connecting Cable

www.micruscorp.com

CAUTION: Federal (U.S.A.) law restricts this device to sale by or on the order of a physician.MICRUS, MICRUS ENDOVASCULAR, PRESIDIO, MICRUSPHERE, ULTIPAQ, HELIPAQ, INTERPAQ, and the M logo are registered trademarks of Micrus Endovascular Corporation.RUSSIAN DOLL, FRILLING, CASHMERE, and EnPower are trademarks of Micrus Endovascular Corporation.© 2008 Micrus Endovascular Corporation. All rights reserved.

Avenue des Baumettes 71020 RenensSwitzerland

T +41.21.631.3434F +41.21.631.3444

821 Fox LaneSan Jose, CA 95131United States

T 408.433.1400F 408.433.1401

1st Floor, Unit 4Stansted CourtyardTakeleyBishop’s StortfordEssexCM22 6PUUnited Kingdom

T +44.800.612.6363F +44.800.612.8484

P/N 50876-02 REV A

REFERENCES:1. Piotin M, Iijima A, Wada H, Moret J. Increasing the packing of small aneurysms with complex-shaped coils: an in vitro study.

AJNR Am J Neuroradiol. 2003;24:1446-1448.2. Wakhloo AK, Gounis MJ, Sandhu JS, Akkawi N, Schenck AE, Linfante I. Complex-shaped platinum coils for brain aneurysms: higher

packing density, improved biomechanical stability, and midterm angiographic outcome. AJNR Am J Neuroradiol. 2007;28:1395-1400.3. Vallee JN, Pierot L, Bonafe A, et al. Endovascular treatment of intracranial wide-necked aneurysms using three-dimensional coils:

predictors of immediate anatomic and clinical results. AJNR Am J Neuroradiol. 2004;25;298-306.4. Gonzalez N, Murayama Y, Nien YL, et al. Treatment of unruptured aneurysms with GDCs: clinical experience with 247 aneurysms.

AJNR Am J Neuroradiol. 2004;25:577-583.

S T R E N G T H T A K E S S H A P E

M I C R U S M I C R O C O I L S

OptimizeNeckCoverage

ImprovedneckprotectionwiththePRESIDIOMicrocoil

TheanatomicallycompliantframeandhighshapememoryofMicrusMicrocoilsaredesignedtoimproveneckcoverageandprovide:

•Stablescaffoldingthatcoverstheneck

•Fillingofopenspaces,especiallyinregionofaneurysmalneck

•Littleriskofcoilprotrusionthroughtheneck,eveninwidenecks

•Littleriskofframedeformation3

NeckcoverageisoptimizedwiththePRESIDIOMicrocoil,especiallywhenusedintheRussianDolltechnique.Thecoilisastableframeandanexcellentfillingcoil,whichhasenabledustocoilmanywide-neckedaneurysmswithouttheneedforastent.

AveryEvans,MD,UniversityofVirginia

Neckremnantsobservedangiographicallyaftercoilingtripletheriskofcompactionandrecanalization.4

8.75 in.8.71875 in.

8.71875 in.

0.21875 in.

8.75 in.

11.25in.11

.25

in.

8.81

25in

.

0.21

875

in.

0.75

in.

0.21

875

in.

0.75

in.

0.25

in.

0.25

in.

07-MIC-030 MICRUS MICROCOIL FAMILY BROCHURE BLACK CYAN MAGENTA YELLOW PMS877 DIELINE

BLACK CYAN MAGENTA YELLOW PMS 877

OUTSIDE