The New Normal: Water Users Squeezed · Perm TDS 202 ppm Conc. TDS 80,108 ppm Annual Evaporator...
Transcript of The New Normal: Water Users Squeezed · Perm TDS 202 ppm Conc. TDS 80,108 ppm Annual Evaporator...
1
The New Normal: Water Users Squeezed
2
Brackish water
Declining feed
water quality
Receiving body
Increasing discharge requirements /
zero liquid discharge
Water customers
Municipal WWTPSeawater
Recovered water
The DOW FILMTEC™ FORTILIFE™ family of
elements offers industrial users a reliable and highly
efficient option to help solve their most difficult
water challenges, such as wastewater reuse and
minimal liquid discharge.
Our proposal
Dow FORTILIFETM Membrane Family
FOULING RESISTANT HIGH
SALINITY ELEMENT
> 15 g/L
FOULING RESISTANT
LOW ENERGY HIGH
SALINITY ELEMENT
> 15 g/L
SELECT ION SEPARATION
ELEMENT
FOR BRINE RECYCLE
CR100
XC70
XC80
XC-N
Product Features Specifications1 Benefit
• Permeate Flow: 30.6 m³/h
• Stab. Salt Rejection: 99.7%
• Max. Feedpressure: 83 bar
• Permeate Flow: 34.2 m³/h
• Stab. Salt Rejection: 99.4%
• Max. Feedpressure: 83 bar
• Permeate Flow: 31 m³/h
• Stab. Salt Rejection: 99.0%
• Max. Feedpressure: 41 bar
• REDUCE CLEANING
FREQUENCY
• MORE UP-TIME
• LONGER ELEMENT LIFE
• REDUCE ENERGY COSTS
• INCREASE RECOVERY
• REDUCE CLEANING
FREQUENCY
• MAKE BRINE REUSABLE
• REDUCE WASTE
• LOW ENERGY OPERATION
BIOFOULING RESISTANT
HIGH REJECTION LOW
SALINITY WATER ELEMENT
< 15 g/L
• REDUCE CLEANING
FREQUENCY CAUSED BY
BIOFOULING UP TO 50%
• Permeate Flow: 44 m³/h
• Stab. Salt Rejection: 99.7%
• Max. Feedpressure: 41 bar
1) Please refer to product data sheet for detailed information
Value Proposition
5
FORTILIFE™ CR100Fewer Cleanings are in Your Future.
6
FORTILIFE™ CR100Fewer Cleanings are in Your Future.
• Lower CIP frequency caused by biofouling
by up to 50%* versus market standard
� more up-time, higher overall system recovery
� longer element lifetime
• Reduce energy consumption by up to 10%**
* Depending on feed water quality and operating conditions** At the same operating flux and recovery
It is achieved by applying an innovative membrane design that reducesdifferential pressure and bacteria adhesion significantly
FORTILIFE™ CR100
˃50% reduction
Competitor A
Competitor B
Side-by-side evaluation of two banks of 8 elements (2540) in series with matching flux and recovery. Softened groundwater with nutrient dosing.
BW30XFR
3 CIP / 107 days
Average CIP Frequency= 0.79 cleanings / month
FORTILIFETM CR100
3 CIP / 176 days
Average CIP Frequency= 0.48 cleanings / month
CIP 1 CIP 2 CIP 3
39% reduced CIP Frequency
CIP 1 CIP 2 CIP 3
FORTILIFE™ CR100 Pilot Study 1
0
1
2
3
4
0
10
20
30
40
50
60
0 20 40 60 80 100 120 140 160 180
Pre
ssure
Dro
p (b
ar)
Pre
ssure
Dro
p (
psi
)
0
1
2
3
4
0
10
20
30
40
50
60
0 20 40 60 80 100 120 140 160 180
Pre
ssure
Dro
p (b
ar)P
ress
ure
Dro
p (
psi
)
Operating Days
10
FORTILIFE™ CR100 Pilot Study 2
Side-by-side field trial: two banks of 6 x 4 inch elements in series operated with matching flux and recovery. Nutrient dosed Wastewater (Tarragona, Spain)
� 29% reduction in CIP frequency *
*This is a pilot study; we recommend to follow FILMTECTM cleaning procedure
FORTILIFE™ XC seriesClean Less. Recover More.
11
FORTILIFE™ XC70 / XC80 Clean Less. Recover More.
• Reduce RO concentrate volume by up to 7%* to
achieve a higher membrane system recovery at
roughly 12.5%** of the cost.
12
* Depending on feed water quality and operating conditions
** Depending on specific brine concentration technology
It is achieved by combining Dow’s most permeable yet fouling-resistant membrane with easy-to-clean module construction.
FORTILIFE™ XC70 / XC80 Case Simulation
13
Wastewater ReuseRO Concentrate150 m³/h; TDS 7045 ppm
Evaporator
Desired TDS:
60,000 - 90,000 mg/LRO2RO1
Permeate Reuse
XC70/80CR 100
Permeate Reuse
Competitive
offering
RO1 Standard FR BWRO
RO2 (Stage 1) Standard SWRO
RO2 (Stage 2) Standard SWRO
Vol. of Water to evaporator 26.2 m3/h
Perm TDS 202 ppm
Conc. TDS 80,108 ppm
Annual Evaporator OPEX1 $1,153,152
Annual Evaporator savings benchmark
Savings ($/yr/element) benchmark
FORTILIFE
Family
FORTILIFE CR100
FORTILIFE XC70
FORTILIFE XC80
24.0 m3/h
237 ppm
85,260 ppm
$1,057,716
$95,436
$ 221
1Evaporator cost: $5.5/m3 feed; hours operation: 8000 h/y
~ 10% saving on evaporation!
FORTILIFE™ XC-NRecover More. Reduce Waste.
• Reduce costly RO concentrate waste by converting a
large fraction of it into purified, easier-to-crystallize
salt solution.
14
It is achieved by the use of a highly permeable and ion-selective NF membrane with high NaCl passage, and high divalent and COD rejection
FORTILIFE™ XC-N Lab test
RO Concentrate
Flow: 130 m3/h
• TDS: 36,400ppm• NaCl: 17,000ppm• Na2SO4: 17,751ppm• COD: 350ppm
NF Concentrate
to evaporation
Flow: 26 m3/h
• TDS: 109,000ppm• NaCl: 13,700ppm• Na2SO4: 88,155ppm• COD: 1,200ppm
NF Permeate
for reuse
Flow: 104 m3/h
• TDS: 18,250ppm• NaCl: 17,825ppm• Na2SO4: 150ppm• COD: 140ppm
RO System
80% water reduction1.8% NaCl solution
@ 97.6% Purity
FORTILIFE XC-N
Value Proposition Summary
16
FORTILIFE™
CR100
FORTILIFE™
XC70 / XC80
FORTILIFE™
XC-N
VALUE PROPOSITION KEY END RESULT BENEFIT
Higher Recovery
Improved Engineering
Value Differentiation for Top
Tier OEMs
Smaller concentrate handling
systems like dryers or crystallizers
Increased overall system recovery
Reduced energy consumption
Lowers CIP frequency up to 50%
Reduces energy up to 10%
Innovative feed spacer
More up-time
Higher overall system recovery
Longer element lifetime
Reduced maintenance costs
Lower Differential Pressure
Higher divalent and COD
rejection
Obtain easier-to-crystallize
salt solution
Reduce costly RO concentrate waste
Cost Incentive due to Environmental
Compliance
Applications & Industries
17
Wastewater reuse Petrochemical
Minimum liquid discharge Pulp & Paper
Brine management Textile
Waters with high biofouling potential
Power
Thank you
18
® ™Trademark of The Dow Chemical Company
Additional Slides for TS
19
Purified
6-10%
1NaCl
The FORTILIFETM Family
Dow Ultrafiltration
Dow IX resins
FORTILIFETM CR100
FORTILIFETM XC70/XC80
DOW UHP RO
FORTILIFETM XC-N
Evaporator
Waste Solids
Water for
recycle
Purified Brine
for recycle
Pretreatment
MAXIMIZE
MAXIMIZE
MINIMIZE
Approx.
Conc. TDS
0.5-1.5%
1.5-8%
6-10%
10-20%
Prim
ary
WR
U
MLD
/B
rine C
onc.
Wastewater Reuse Minimal Liquid Discharge
- high biofoulingpotential
- high biofouling potential- high recovery- low energy
- high biofouling potential- high recovery- low energy- brine recovery- minimize waste salts
- high biofouling potential- max recovery
Application Examples
21
TDS range0 - 15 g/L
• FORTILIFE™ CR100 TDS range
0 - 15 g/L
• FORTILIFE™ CR100
TDS range15 – 80 g/L
• FORTILIFE™ XC70 (1st stage)
• FORTILIFE™ XC80 (2nd Stage)
TDS range0 - 15 g/L
• FORTILIFE™ CR100
TDS range15 – 80 g/L
• FORTILIFE™ XC70 (1st stage)
• FORTILIFE™ XC80 (2nd Stage)
TDS range60 – 100 g/L
FORTILIFE™ XC-N
TDS range0 - 15 g/L
• FORTILIFE™ CR100
TDS range15 – 80 g/L
• FORTILIFE™ XC70 (1st stage)
• FORTILIFE™ XC80 (2nd Stage)
TDS range100 – 200 g/L
• Dow UHP RO(Ultra High Pressure )
Application Overview
Industrial WW
Precipitation Processes
(e.g. Lime and/or Iron, optional)
Filtration Processes
(e.g. Sand, GAC, optional)
Dow Ultrafiltration
(Particle removal)
Dow Ion Exchange
(Scaling prevention)
RO 2
DOW FORTILIFE
CR100
Dow FORTILIFE
XC70/XC80RO 1
0.05 – 1%TDS
1 – 4%TDS
5 – 8%TDS
To discharge, post treatment or further use
Ion selective membrane
Dow FORTILIFE
XC N
Dow Specialty Membranes
Ultra High Pressure RO
5 – 8%TDS
5 – 8%TDS
10 – 20% TDS
1 - 8% TDS
6 - 10%TDS
Water reuse
< 100 mg/L TDS
Water reuse
< 400 mg/L TDS
Water reuse
< 1000 mg/L TDS
Purified brinefor further use4 - 6% TDS
Application Overview
Industrial WW
Precipitation Processes
(e.g. Lime and/or Iron, optional)
Filtration Processes
(e.g. Sand, GAC, optional)
Dow Ultrafiltration
(Particle removal)
Dow Ion Exchange
(Scaling prevention)
High feed salinityCR100
Low feed salinity
0.05 – 1%TDS
1 – 4%TDS
To discharge, post treatment or further use
Very high feed salinity
Dow Specialty Membranes
Ultra High Pressure RO
5 – 8%TDS
10 – 20% TDS
1 - 8% TDS
6 - 10%TDS
Permeate for reuse
TDS < 100 mg/L
Permeate for reuse
TDS < 400 mg/L
Permeate for reuse
TDS < 1000 mg/L
Purified brine for further use
4 - 6% TDS
XC70XC80
XC-N