THE GAP BACK TO WALL TOILET SUITE...ROCA THE GAP BACK TO WALL TOILET SUITE SPECIFICATION Recommended...

5
ROCA THE GAP BACK TO WALL TOILET SUITE SPECIFICATION Recommended Use Domestic, hotel and commercial Rim Configuration Box Rim Bowl Configuration P Trap (Converts to S using plastic S-bend provided) Set Out P Trap: 180mm, S Trap: 125mm-225mm Pan Fixing Screwed to the floor using brackets (supplied) and bedded with sealant Cistern Fixing Top-fix cistern bolted directly to the bowl Seat Matching top-fix, soft-close, quick-release seat supplied with suite Water Inlet Back inlet, left hand side Cistern 4.5/3 litre dual flush Inlet Valve Recommended max. working pressure 1000kPa Weight Pan: 29.8kg, Cistern: 10.7kg WELS 4 Star WELS Rating Standards AS1172.1 and AS 1172.2 CLEANING RECOMMENDATIONS Soapy water or approved bathroom cleaners. This bathroom product should not be cleaned with abrasive materials. Damage caused by any improper treatment is not covered by the product warranty. Refer to Warranty Page for full Terms and Conditions. To see the complete Roca range go to www.reece.com.au/bathrooms WMKA 02321 365 340 650 400 225 440 150 Min 125 - Max 225 220 790 ~720 100 180 page 1 of 5 Disclaimer: Products in this specification manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification. Dimensions and set-outs listed are correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors. Tech Page Version 2 Dimensions are nominal only The more stars the more water efficient WATER RATING www.waterrating.gov.au In accordance with AS/NZS 6400 Licence No. 0137 Bathroom Products Australia 4.5 L per full flush / 3 L per half flush 3.5 litres average flush

Transcript of THE GAP BACK TO WALL TOILET SUITE...ROCA THE GAP BACK TO WALL TOILET SUITE SPECIFICATION Recommended...

Page 1: THE GAP BACK TO WALL TOILET SUITE...ROCA THE GAP BACK TO WALL TOILET SUITE SPECIFICATION Recommended Use Domestic, hotel and commercial Rim Configuration Box Rim Bowl Configuration

ROCATHE GAP BACK TO WALL TOILET SUITE

SPECIFICATIONRecommended Use Domestic, hotel and commercial

Rim Configuration Box Rim

Bowl Configuration P Trap (Converts to S using plastic S-bend provided)

Set Out P Trap: 180mm, S Trap: 125mm-225mm

Pan Fixing Screwed to the floor using brackets (supplied) and bedded with sealant

Cistern Fixing Top-fix cistern bolted directly to the bowl

Seat Matching top-fix, soft-close, quick-release seat supplied with suite

Water Inlet Back inlet, left hand side

Cistern 4.5/3 litre dual flush

Inlet Valve Recommended max. working pressure 1000kPa

Weight Pan: 29.8kg, Cistern: 10.7kg

WELS 4 Star WELS Rating

Standards AS1172.1 and AS 1172.2

CLEANING RECOMMENDATIONSSoapy water or approved bathroom cleaners.

This bathroom product should not be cleaned with abrasive materials.

Damage caused by any improper treatment is not covered by the product warranty. Refer to Warranty Page for full Terms and

Conditions.

To see the complete Roca range go to www.reece.com.au/bathrooms

WMKA02321

365

340

650

400

225

440

150

Min 125 - Max 225

220

790~720

100

180

page 1 of 5

Disclaimer: Products in this specification manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification. Dimensions and set-outs listed are correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors.

Tech Page Version 2

Dimensions are nominal only

The more stars the more water efficient

WATER RATINGwww.waterrating.gov.au

In accordance with AS/NZS 6400

Licence No. 0137Bathroom Products Australia

4.5 L per full flush / 3 L per half flush

3.5 litres average flush

Page 2: THE GAP BACK TO WALL TOILET SUITE...ROCA THE GAP BACK TO WALL TOILET SUITE SPECIFICATION Recommended Use Domestic, hotel and commercial Rim Configuration Box Rim Bowl Configuration

ROCATHE GAP BACK TO WALL TOILET SUITE

INSTALLATION

HA

H

100

225

180

AV0007000r

Min: 125Max: 225

A34247W..r

A34247C..r

Product code

A34247W..r

A34247C..r

H400

440

HA720

760

1 - AH0001700r

2 - A822096400

3 - AH0000100r

4 - AV0028800r

5 - AV0009400r

1

3

4

2

5

The GAP BTWA34147T..r

page 2 of 5

Page 3: THE GAP BACK TO WALL TOILET SUITE...ROCA THE GAP BACK TO WALL TOILET SUITE SPECIFICATION Recommended Use Domestic, hotel and commercial Rim Configuration Box Rim Bowl Configuration

ROCATHE GAP BACK TO WALL TOILET SUITE

INSTALLATION

8

Ø 5

1

2

page 3 of 5

Page 4: THE GAP BACK TO WALL TOILET SUITE...ROCA THE GAP BACK TO WALL TOILET SUITE SPECIFICATION Recommended Use Domestic, hotel and commercial Rim Configuration Box Rim Bowl Configuration

ROCATHE GAP BACK TO WALL TOILET SUITE

INSTALLATION

195mm

18 19

16 17

20

21

22 23

page 4 of 5

Page 5: THE GAP BACK TO WALL TOILET SUITE...ROCA THE GAP BACK TO WALL TOILET SUITE SPECIFICATION Recommended Use Domestic, hotel and commercial Rim Configuration Box Rim Bowl Configuration

ROCATHE GAP BACK TO WALL TOILET SUITE

A82

2728

F0R

d

AH0007100r

1

21

2

1

2

2

1

60 mm

[email protected]@roca.net

roca Sanitario, S.A.Avda. Diagonal, 51308029 BarcelonaSPAINwww.roca.com

page 5 of 5

Plumbers, please ensure a copy of the installation instructions is left with the end user for future reference

MAINTENANCE