The ErP Directive and its impact on switchgear
-
Upload
eaton-europe-middle-east-africa -
Category
Engineering
-
view
550 -
download
1
Transcript of The ErP Directive and its impact on switchgear
1© 2015 Eaton. All Rights Reserved..
Andreas Miessen, Product Manager – EATON, Product Line Drives & Softstarters
2© 2015 Eaton. All Rights Reserved..
EATON
• Foundation in 1911
• Subsidiaries in almost every country of the world
• Innovation Centers in regions around the world
• Moren than 102,000 employees worldwide
• Sales of $22.6 billion in 2014
• 50 % of sales outside the U.S.
Motor
Control
Distribution
Equipment
DC Circuit
Protection
IEC Global Switchgear
Paralleling Switchgear
UPS Products
DC Products
Complete IEC
Low Voltage
Data Center
Solutions
Automation
Systems
Energy
Engineering
1979 1994 1998 2003 2004 20072005 2008 2009 2010 2011 2012
Diversified
electrical
manufacturer
Electrical
distribution
3© 2015 Eaton. All Rights Reserved..
•
•
4© 2015 Eaton. All Rights Reserved..
• ErP Directive
Contents and impacts
• Motor regulations
Impact on motors and their switchgear and protective devices
• Pumps and fan regulations
Achieving required efficiencies using speed control
• New device category
Variable speed starter
Agenda
Simplified, compact &
lower cost machineReliable machine
Energy efficient
machineSafer machine
5© 2015 Eaton. All Rights Reserved..
Energy Efficiency
• Legislation
• ErP Directive
6© 2015 Eaton. All Rights Reserved..
• In today's world, energy efficiency is on
everyone's mind
• The EU is making efforts to meet its
environmental targets
• Laws and regulations play an important role
here as well
• Goal: To use energy in a conscientious manner
and take advantage of energy saving potentials
• For the most part, this is achieved by defining
minimum efficiencies and max. losses
GHD 276 TWh16%
Haushalte 609 TWh
25%
Industrie 729 TWh
30%
Verkehr 714 TWh
29%
Energy Consumption
in Germany 2011
Reliable machineSimplified, compact &
lower cost machineSafer machine
Energy efficient
machine
ErP DirectiveEnergy Efficiency and the Applicable Laws & Regulations
7© 2015 Eaton. All Rights Reserved..
• Creating a framework for defining ecodesign requirements for "energy-related
products"
• Identifying product groups with a high potential for lowering greenhouse gas
emissions cost-effectively
• Examples of product groups that are important for Eaton:
- Electric motor systems
- Pumps
- Fans
• The requirements for these product groups are defined in the corresponding
regulations. For example: EC 640/2009 for electric motors (= motor regulation)
ErP DirectiveThe Goals Behind ErP Directive
Reliable machineSimplified, compact &
lower cost machineSafer machine
Energy efficient
machine
8© 2015 Eaton. All Rights Reserved..
ErP DirectiveImplementation Guidelines / Regulations
Reliable machineSimplified, compact &
lower cost machineSafer machine
Energy efficient
machine
9© 2015 Eaton. All Rights Reserved..
ErP DirectiveImpact on the Market
In order to meet the corresponding requirements:
• the relevant products (keyword: IE2 / IE3 motors) need to be modified
• even entire processes need to be modified
(keyword: regulating flow rates with valves vs. variable pump speeds)
Eaton has responded to the changes in the market
with two main approaches:
• Switchgear and protective devices must be IE3-ready
• Developing a new device category
Ease of use of switchgear with variable speeds
Reliable machineSimplified, compact &
lower cost machineSafer machine
Energy efficient
machine
10© 2015 Eaton. All Rights Reserved..
Motor Regulations
• Content, Scope
• IE3 suitability of switching and protection devices
11© 2015 Eaton. All Rights Reserved..
70
75
80
85
90
95
100
1 10 100 1000
Mo
tor
eff
icie
ncy (
%)
Motor power (kW)EFF1
EFF2
IE2
High
IE1
Standard
IE3
Premium
IE4
Super Premium
Higher
efficiency
Lower
efficiency
IE1
IE2
IE3
IE4
Class
Classification
speed
(1/min)
Continuous
duty torque
(Nm)
Classification
power
(kW)
Nominal
efficiency
(%)
Energy loss
(W)
As per
IE1
IE1 1.500 35 5.5 87.4 693
IE2 1.500 35 5.5 87.7 676.5 -2.4%
IE3 1.500 35 5.5 89.6 572 -21.2%
IE4 1.500 35 5.5 92 440 -57.5%
Motor RegulationsEfficiency Classes on Motors
Reliable machineSimplified, compact &
lower cost machineSafer machine
Energy efficient
machine
12© 2015 Eaton. All Rights Reserved..
June 2011 January 2015 January 2017
Motors must belong
to efficiency class
IE2 at the very least
[7.5–375 kW] motors:
IE3 at the very least
or
IE2 + speed control
[0.75–375 kW] motors:
IE3 at the very least
or
IE2 + speed control
Motor RegulationsEfficiency
Reliable machineSimplified, compact &
lower cost machineSafer machine
Energy efficient
machine
13© 2015 Eaton. All Rights Reserved..
Motor RegulationsTechnical Consequences
Reliable machineSimplified, compact &
lower cost machineSafer machine
Energy efficient
machine
14© 2015 Eaton. All Rights Reserved..
Tripping
characteristics PKZM0 …
Motor characteristics
The current when the motor
is started and the inrush peak current both
fall below the trip characteristic.
However, magnetic release tolerances
must be taken into account within the
inrush peak current range, as nuisance
tripping may occur due to these tolerances.
Instantaneous release response current
increased from 14*In to 15.5*In.
Motor RegulationsExample: Modifying Motor Starters
Reliable machineSimplified, compact &
lower cost machineSafer machine
Energy efficient
machine
15© 2015 Eaton. All Rights Reserved..
Eaton Motor starters are the most simple,
ready to use and reliable way to run IE3 motors
Motor RegulationsMotor Starter “IE3 Ready”
Reliable machineSimplified, compact &
lower cost machineSafer machine
Energy efficient
machine
16© 2015 Eaton. All Rights Reserved..
Pumps and Fan Regulations
• Content
• Valve system versus speed control system
17© 2015 Eaton. All Rights Reserved..
Pumps and Fan RegulationsContent
• The pump and fan regulations specify minimum efficiencies for a system
• In many cases, existing flow rate regulation systems, such as those using
valves, will not meet the corresponding requirements
• Speed control systems are required in these cases in order to reduce losses
Reliable machineSimplified, compact &
lower cost machineSafer machine
Energy efficient
machine
18© 2015 Eaton. All Rights Reserved..
Source: ZVEI
Pumps and Fan RegulationsComparison Energy Consumption Valve System vs. Speed Control System
Reliable machineSimplified, compact &
lower cost machineSafer machine
Energy efficient
machine
19© 2015 Eaton. All Rights Reserved..
0
2
4
6
8
10
12
14
16
18
0 10 20 30 40 50 60 70 80 90 100
Perf
orm
an
ce (
kW
)
Flow (%)
Throttle Valve
Speed Control
Pumps and Fan RegulationsComparison Energy Consumption Valve System vs. Speed Control System
Reliable machineSimplified, compact &
lower cost machineSafer machine
Energy efficient
machine
20© 2015 Eaton. All Rights Reserved..
• Options for starting motors
• The simplest type of variable motor speed
Variable Speed Starter
21© 2015 Eaton. All Rights Reserved..
Star/delta
Constant
Reduced
Abrupt switching
Speed starter
Variable
Full
Soft start
DOL starter
Constant
Full
Abrupt start
Variable
frequency
drive
Variable
Full
Soft start
Cost / functionality
Speed
Torque
Behavior at start
New Device Category: Variable Speed StarterOptions for Starting Motors
Reliable machineSimplified, compact &
lower cost machineSafer machine
Energy efficient
machine
22© 2015 Eaton. All Rights Reserved..
The simplest type of variable motor speed
• Positioned between motor starters and frequency converter
• Design and appearance of a motor starter
• Ability of the variable speed control adjustment
• Out-of-the-box-commissioning without any parameterization
New Device Category: Variable Speed StarterThe Starter with Variable Speed
Reliable machineSimplified, compact &
lower cost machineSafer machine
Energy efficient
machine
23© 2015 Eaton. All Rights Reserved..
• Applications in which a DOL start is not acceptable due to mechanical
reasons or excessively high inrush currents
• Applications that already feature a motor starter but that will require
speed control in the future in order to meet the applicable legal
requirements
• Applications that already feature a low-end variable frequency drive, but
for which this drive is still too complex (or too expensive)
• Applications with fixed speeds in which a frequency other than the
mains frequency is required
• Fixed-speed applications, with a high starting frequency
New Device Category: Variable Speed StarterApplications
Reliable machineSimplified, compact &
lower cost machineSafer machine
Energy efficient
machine
24© 2015 Eaton. All Rights Reserved..
2,2 kW @ 230 V / 2,2 … 7,5 kW @ 400 V
0,25 … 1,5 kW @ 1~ 230 V & 3~ 400 V
…… on public grids and industrial
supply systems
Featuring integrated motor protection
New Device Category: Variable Speed StarterUsed Everywhere in the World
Reliable machineSimplified, compact &
lower cost machineSafer machine
Energy efficient
machine
25© 2015 Eaton. All Rights Reserved..
Ambient temperature:
• Operating : -10…60 °C (device for 7.5 kW with derating)
• Storage : -40…70 °C
• Can be mounted directly side-by-side without derating
• Can be mounted on DIN-rails and mounting plates
• Degree of protection: IP20
New Device Category: Variable Speed StarterPerfect for Panel Building
Reliable machineSimplified, compact &
lower cost machineSafer machine
Energy efficient
machine
26© 2015 Eaton. All Rights Reserved..
New Device Category: Variable Speed StarterReliable Operation
Integrated functions
designed to prevent nuisance tripping :
• The output voltage and frequency are automatically adjusted during
generator operation or excessively steep deceleration ramps in order
to prevent shutdowns due to overvoltage
• The switching frequency is automatically reduced if
the heat sink temperature is too high
• DC braking for preventing shutdowns due to overcurrent –
in fans, for example
Reliable machineSimplified, compact &
lower cost machineSafer machine
Energy efficient
machine
27© 2015 Eaton. All Rights Reserved..
… parameterized with the screwdriver
• Ramp times
• Motor protection
• Terminal configuration
• Mains voltage change
(50 Hz / 60 Hz)
Power XL DE1 Variable Speed Starter – the simplest way
to manage IE2 & IE3 motors in variable speed applications
New Device Category: Variable Speed StarterIf necessary…
Reliable machineSimplified, compact &
lower cost machineSafer machine
Energy efficient
machine
28© 2015 Eaton. All Rights Reserved..
Conclusion
Summarizing it……
• The ErP Directive must be considered for all AC motors up to 375 kW.
Eaton offers the most simple, low cost and reliable way to fulfill it
already today.
• In applications with constant speed it must be taking care of that the
motor starters are „IE3 ready“.
• The Variable Speed Starter offers an ideal solution in simple
applications with variable speed.
• From a motor starter to a variable frequency drive – Eaton provides
the optimum solution for every requirement.
Simplified, compact &
lower cost machineReliable machine
Energy efficient
machineSafer machine
29© 2015 Eaton. All Rights Reserved..
Further Information
Simplified, compact &
lower cost machineReliable machine
Energy efficient
machineSafer machine
„Motor Protection for the
IE3 revolution “
„Successful implementation
of the ErP Directive“
For more information, you can visit : www.eaton.eu/IE3
30© 2015 Eaton. All Rights Reserved..