The Effect of Fluorescent Labelling on Deformability and Geometric Properties of Red Blood Cells...

16
The Effect of Fluorescent Labelling on Deformability and Geometric Properties of Red Blood Cells Joanne Wong Supervisor: Dr. D. Jackson March 23,2011 Medical Biophysics Department University of Western Ontario

Transcript of The Effect of Fluorescent Labelling on Deformability and Geometric Properties of Red Blood Cells...

Page 1: The Effect of Fluorescent Labelling on Deformability and Geometric Properties of Red Blood Cells Joanne Wong Supervisor: Dr. D. Jackson March 23,2011 Medical.

The Effect of Fluorescent Labelling on Deformability and Geometric

Properties of Red Blood Cells

Joanne WongSupervisor: Dr. D. Jackson

March 23,2011Medical Biophysics Department University of

Western Ontario

Page 2: The Effect of Fluorescent Labelling on Deformability and Geometric Properties of Red Blood Cells Joanne Wong Supervisor: Dr. D. Jackson March 23,2011 Medical.

Acknowledgement

• Supervisor: Dr. Dwayne N. Jackson• Graduate Student Mentor: Baraa Al-Khazraji• Source of funding: NSERC

Page 3: The Effect of Fluorescent Labelling on Deformability and Geometric Properties of Red Blood Cells Joanne Wong Supervisor: Dr. D. Jackson March 23,2011 Medical.

Introduction• Blood cells• Hemodynamic• Directly measure• Microspheres and fluorescent cells• Trace cells in microvasculature • Do stained cells behave the same as unstained

cells?

Page 4: The Effect of Fluorescent Labelling on Deformability and Geometric Properties of Red Blood Cells Joanne Wong Supervisor: Dr. D. Jackson March 23,2011 Medical.

Hypothesis

There will be no differences in deformability or geometry between stained and unstained red blood cells

Page 5: The Effect of Fluorescent Labelling on Deformability and Geometric Properties of Red Blood Cells Joanne Wong Supervisor: Dr. D. Jackson March 23,2011 Medical.

Methods

Dye and incubate5 hours (FITC) Wash cells

1 hour

Extract blood

Hang test2 minutes

Image slides

Split portions

Page 6: The Effect of Fluorescent Labelling on Deformability and Geometric Properties of Red Blood Cells Joanne Wong Supervisor: Dr. D. Jackson March 23,2011 Medical.

Methods• Hang test

• ImageJ

Page 7: The Effect of Fluorescent Labelling on Deformability and Geometric Properties of Red Blood Cells Joanne Wong Supervisor: Dr. D. Jackson March 23,2011 Medical.

Theoretical Model

• Criteria for measurements

Circle diameter

Diameter

Thickness

(2)

Page 8: The Effect of Fluorescent Labelling on Deformability and Geometric Properties of Red Blood Cells Joanne Wong Supervisor: Dr. D. Jackson March 23,2011 Medical.

Theory

Page 9: The Effect of Fluorescent Labelling on Deformability and Geometric Properties of Red Blood Cells Joanne Wong Supervisor: Dr. D. Jackson March 23,2011 Medical.

Results

n = 99n = 99

Mean value :Unstained= 7.624 ± 0.475 µmStained= 7.440 ± 0.367 µmA T-test was performed with p value = 0.179

Unstained Stained0

1

2

3

4

5

6

7

8

Diameter Value for Stained and Unstained Rat Blood Cells

Dia

mte

r (µm

)

n=20n=20

Page 10: The Effect of Fluorescent Labelling on Deformability and Geometric Properties of Red Blood Cells Joanne Wong Supervisor: Dr. D. Jackson March 23,2011 Medical.

n = 99n = 99

Mean value :Unstained= 130.890 ± 15.711 µm2

Stained = 125.490 ± 12.739 µm2

A T-test was performed for a p value = 0.24

Unstained Stained0

20

40

60

80

100

120

140

Surface Area for Stained and Unstained Rat Blood Cells

Surf

ace

Are

a (µ

m2)

n=20n=20

Page 11: The Effect of Fluorescent Labelling on Deformability and Geometric Properties of Red Blood Cells Joanne Wong Supervisor: Dr. D. Jackson March 23,2011 Medical.

n = 99n = 99

Mean value :Unstained= 48.544 ± 10.025 µm3

Stained = 46.158 ± 4.615 µm3

A T-test was performed with a p value = 0.340

Unstained Stained0

10

20

30

40

50

60

Volume of Stained and Unstained Rat Blood Cells

Volu

me

(µm

3)

n=20n=20

Page 12: The Effect of Fluorescent Labelling on Deformability and Geometric Properties of Red Blood Cells Joanne Wong Supervisor: Dr. D. Jackson March 23,2011 Medical.

n = 99

Mean value :Unstained= 0.490± 0.022Stained = 0.498 ± 0.037A T-test was performed with a p value = 0.357

Unstained Stained0

0.1

0.2

0.3

0.4

0.5

Sphericity Index Value for Stained and Unstained Rat Blood Cells

Sphe

rici

ty In

dex

n=20n=20

Page 13: The Effect of Fluorescent Labelling on Deformability and Geometric Properties of Red Blood Cells Joanne Wong Supervisor: Dr. D. Jackson March 23,2011 Medical.

Complementary Study Methods

StainedUnstained

Albumin free Albumin0.5% per 500mL

Albumin 0.5% per 500mL

Page 14: The Effect of Fluorescent Labelling on Deformability and Geometric Properties of Red Blood Cells Joanne Wong Supervisor: Dr. D. Jackson March 23,2011 Medical.

Complementary StudyUnstained Stained

No Albumin ~5% abnormal shaped

Albumin ~95% abnormal shaped

~30% abnormal shaped

Page 15: The Effect of Fluorescent Labelling on Deformability and Geometric Properties of Red Blood Cells Joanne Wong Supervisor: Dr. D. Jackson March 23,2011 Medical.

Summary & Discussion

• Simple math model vs. hand tracing• Results showed no significant difference• Effects of albumin buffer• FIT-C dye does not affect deformability and

geometrical difference• Possible modification of staining protocol?

Page 16: The Effect of Fluorescent Labelling on Deformability and Geometric Properties of Red Blood Cells Joanne Wong Supervisor: Dr. D. Jackson March 23,2011 Medical.

Thank You!

Contact me at: [email protected]