The DuPont Performance Polymers Laboratory (Elastomers ) DPP Lab.pdf · The DuPont Performance...
Transcript of The DuPont Performance Polymers Laboratory (Elastomers ) DPP Lab.pdf · The DuPont Performance...
DuPont Performance Polymers ConferenceDuPont Performance Polymers Conference
May 20May 20th,th, 20102010
AlbergoAlbergo CoccaCocca HotelHotel
SarnicoSarnico ((BgBg))
Patrick Patrick PagliaPaglia
The DuPont Performance The DuPont Performance PolymersPolymers LaboratoryLaboratory((ElastomersElastomers))
22
� Outskirt of Geneva
� 250 people
� DPP - Elastomers lab : 22 people
� Technical Support to customers located in Europe & abroad
� Vamac®, Viton®, Kalrez®, Viton® Free Flow, Neoprene
� ISO/TS 16949:2009 (Viton®) & ISO 9001:2008 (all products)
� Yearly Compounder Course – next June 2010
European Technical Center
33
What’s unique to ETC
� Many professionals with multiproduct experience
� Broadest range of diversity and language skills
� Central geographical location / time zone
� Well integrated with the business
� Well integrated & synergies with DuPont labs
44
� A TS&D LAB with unique or clearly differentiated capabilities within DPE, serving a strategic technology segment
� Critical mass (staffing, investment, competencies) to provide full service for that technology or market segment world wide
� Close links and exchanges with other leading, non-competing players active in the same value chain for the technology (for example, mould manufacturers)
� Ideally geographically close to the main markets
� Provides support to the other regions
DPP definition of TS&D Lead Center
55
� Several mills – four (0.5 kg to 15 kg)
� Internal mixer – two (1.6 liter & 9 liter)
� Presses for slabs
� Mooney, MDR, RPA, MTS, Goettfert, Rosand capillary
� + standard testing equipment (Tensile, TR 10, etc.)
� Injection moulding machines – three
� 2K injection moulding machine
� Oven for post-cure & aging
� Explosive Decompression Unit
� Strong analytical capabilities
Elastomers lab of the Europen Technical Center
66
Injection moulding capability
� MIR, 135 tons
� 38 mm barrel
� Reciprocating screw
� Essentially o-ring moulds of various part dimension s & surface finishes
� One vertical & two horizontal injection moulding mac hines
� Product development beyond conventional rubber lab equipments (RPA, capillary rheometer, etc…)
0123456789
10
60 65 70 75 80 85 90 95 100 105 110
Injection Pressure (bar)
Inje
ctio
n T
ime
(s)
Viton GBL-S
Viton GBL
� Optimisation of custom compounds – flow & release
77
Injection moulding capability
� To cope with broader DPP portfolio
� Maplan, 300 tons
� 27 mm barrel, L/D 13
� Ideal for low volume compounds, e.g. evaluation of experimental polymers
� Quick cleaning for transitions
� New entry :
� O-ring moulds
� Diversification of mould estate :
� Multiple cavity moulds for broad processing assessments in one go : flow, release, scorch
� Special projects : brush for long runs
88
Injection moulding capability
� Vertical injection noulding machine
� REP, 70 tons
� Bonded parts
99
Peel sample
Zytel ® FE 270056Vamac® Ultra IP
Optimum process parameters
Vamac® cavity: 190°C
Curing time: 45 sec
Post cure: 40min @ 190ºC
Total cycle time: 70 sec
Hardness, Shore A: 60
Compression set: ~20 %
Peel adhesion: >2.5 N/mm
2K injection moulding capability
Rotary table
1010
Compression moulding capability
� Characterisation of new product
� Determination of best releasing aid package
� Optimisation of custom compound with emphasis on release performance
� Complementary to the injection moulding assets
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60
Molding Cycle #
% S
tic
kin
g C
av
itie
s
Viton GLT-S (1% average sticking)Viton GLT (47% average sticking)Viton GLT-505 (37% average sticking)
1111
ED testing equipment
To be compressed(larger piece)
Uncompressed(smaller piece)
A program developed internally ensures constant data acquisition and optimum pressure release
1212
ED testing equipment
� 100 % CO2
� 24 hour exposure
� Temperature : Room Temperature, 100 °C, 150 °C, 200 °C
� Pressure : 5 MPa, 10 MPa, 15 MPa
� Decompression rate : 2 to 12 MPa/min
� One decompression cycle
� Uncompressed and compressed K-325 o-rings (37.47 mm x 5.33 mm, 3 specimen per condition)
� Samples analyzed based on Norsok M-710a visual inspection method
1313
� THERMAL ANALYSIS
� Differential Scanning Calorimeter (D.S.C.)� Thermo Gravimetric Analyzer (T.G.A.)� Thermo Mechanical Analyzer (T.M.A.)
Analytical laboratory
Heat absorptionEndotherm (fusion)
Heat absorptionExotherm (cristallization)
Glass transition (Tg)
D.S.C T.G.A
1414
� SPECTROMETRIC ANALYSIS� Fourier Transformed Infra-Red Spectrometer (F.T.I.R.)
� X-Ray Fluorescence Spectrometer (X.R.F.)
Analytical laboratory
101520253035404550556065707580859095
100.0
%T
4000.03600 3200 2800 2400 2000 1800 1600 1400 1200 1000 800 650.0
FKM > Viton®FFKM > Kalrez®
IR enables a quick and easy differentiation between
fluoroelastomers (FKM) and perfluoroelastomers (FFKM)
Ca KA1-HS-Min
0
0.1
1
2
3
5.56 5.6
1515
� OPTICAL BINOCULAR & IMAGING
� ANALYTICAL FACILITIES FROM OTHER DUPONT DIVISIONS
� COMPLEMENTARY SUPPORT FROM RESEARCH INSTITUTE
Analytical laboratory
1616
Akron extrusion layout
Barrier SectionFKM VTR-7551
Cover SectionTie Layer
Reinforcement Cover
� Product / compound development
� VTR-7551 for thin veneers
� Bonding evaluation of Viton-silicone hoses for turbo charger & industrial applications
Barrier screw used for optimal FKM extrusion
1717
Extruder 1 - FKM
Extruder 2 - tie layer
mandrel
Mandrelon reel
puller
Coextruded hose
Tandem Extruded hoseExtruder 1 - FKM Extruder 2 - tie layer
mandrel
Mandrelon reel
puller
55.0°
Akron multi-extrusion layout
1818
The information set forth herein is furnished free of charge and is based on technical data that DuPont believes to be reliable and falls within the normal range of properties. It is intended for use by persons having technical skill, at their own discretion and risk. This data should not be used to establish specification limits nor used alone as the basis of design. Handling precaution information is given with the understanding that those using it will satisfy themselves that their particular conditions of use present no health or safety hazards. Since conditions of product use and disposal are outside our control, we make no warranties, express or implied, and assume no liability in connection with any use of this information. As with any product, evaluation under end-use conditions prior to specification is essential. Nothing herein is to be taken as a license to operate or a recommendation to infringe on patents.
Caution: Do not use in medical applications involving permanent implantation in the human body. For other medical applications, discuss with your DuPont customer service representative and read Medical Caution Statement H-50103-3.
Copyright© 2010 DuPont™. The DuPont Oval logo, DuPont™, The miracles of science™, DuPont™ Viton® are registered trademarks of E.I. du Pont de Nemours or its affiliates. All rights reserved.