The Continuum of Critical Care - Edwards...

40

Transcript of The Continuum of Critical Care - Edwards...

Page 1: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials
Page 2: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

The Continuum of Critical Care

This catalog provides a comprehensive overview of our critical care portfolio. The portfolio consists of

tools for monitoring patients of varying clinical complexity. Each product and system employs advanced

technologies to provide optimum insight and maximum efficiency within the clinical workflow.

Edwards also offers educational tools and resources to help advance the care and treatment of the

critically ill. Please visit www.Edwards.com/Education to access these complimentary tools, including

the Quick Guide to Cardiopulmonary Care.

Page 3: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

Advanced Minimally Invasive Hemodynamic Monitoring

FloTrac Sensor .........................................................................................................................1

PreSep Oximetry Catheters ...................................................................................................2

PediaSat Oximetry Catheters .................................................................................................3

Vigileo Monitor ......................................................................................................................4

Advanced Hemodynamic Monitoring

Swan-Ganz CCO, Oximetry and CEDV Catheters ..................................................................5

Swan-Ganz Oximetry Thermodilution Catheters..................................................................6

Swan-Ganz Pacing Catheters .................................................................................................7

Swan-Ganz Standard Thermodilution and VIP Catheters ....................................................9

Swan-Ganz No Latex Catheter and Introducer...................................................................10

Swan-Ganz Femoral Vein Insertion Catheters ....................................................................11

Swan-Ganz Pulmonary Angiography Catheters .................................................................12

Swan-Ganz Monitoring Catheters .......................................................................................13

CO-Set+ Closed Injectate Delivery System...........................................................................14

IntroFlex Percutaneous Sheath Introducers ........................................................................15

Vigilance II Monitor ..............................................................................................................17

Pressure Monitoring and Closed Blood Sampling Systems

TruWave Disposable Pressure Transducers and Kits ...........................................................18

VAMP Blood Sampling Systems ...........................................................................................20

TruWave Transducer/VAMP System Combination Kits .......................................................23

Pressure Monitoring Accessories .........................................................................................25

Pediatric Hemodynamic Monitoring

PediaSat Oximetry Catheters ...............................................................................................27

Pediatric Swan-Ganz Catheters............................................................................................28

Pediatric Pressure Monitoring and Closed Blood Sampling System ..................................28

Central Venous Access

Vantex Central Venous Catheters ........................................................................................30

Multi-Med Central Venous Catheters..................................................................................32

Customer Service and Ordering Information ..........................................................................34

Table of Contents

Page 4: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

1

1. A Manecke G, Auger W. “Cardiac Output Determination from the Arterial Pressure Wave: Clinical Testing of a Novel Algorithm That Does Not RequireCalibration.” Journal of Cardiothoracic and Vascular Anesthesia 2007; Vol 21 (1): 3-7

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

AdvancedMinim

allyInvasive

Hem

odyn

amicMonitoring

FloTrac Sensor

FloTrac sensor is a less-invasive hemodynamic monitoring device that provides key flow parameters

(CO, SV, SVV, SVR) from an existing arterial catheter using continuous automatic tone adjustments.

The complete system includes the Vigileo monitor that calculates and displays the key flow parameters.

The FloTrac sensor is accurate, easy to use and less invasive:

• Connects to existing arterial catheter.

• Requires no additional catheters, boluses or chemical indicators enabling rapid set up.

• Continuously monitors changes in the patient’s vascular tone (compliance and resistance).

• Validated against the clinical gold standard Swan-Ganz pulmonary artery catheter1.

• Compatible with Vigileo monitor.

Model Description

MHD6 FloTrac sensor with 60” (152 cm) pressure line

MHD6AZ FloTrac sensor with 60” (152 cm) pressure line and VAMP adult system

MHD8 FloTrac sensor with 84” (213 cm) pressure line

APCO9 FloTrac sensor connecting cable 9’ (274 cm)

PHYSIOTRAC PhysioTrac laser leveler

Advanced Minimally Invasive Hemodynamic Monitoring

Page 5: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

2

1. Rivers EP et al. Early Goal-Directed Therapy in the Treatment of Severe Sepsis and Septic Shock. New England Journal of Medicine 2001; 345 (19):1368-77

* PreSep Oligon oximetry catheters contain an integrated Oligon antimicrobial material. The activity of the antimicrobial material is localized at the cathetersurfaces and is not intended for treatment of systemic infections. In vitro testing demonstrated that the Oligon material provided broad-spectrum effectiveness(≥ 3 log reduction from initial concentration within 48 hours) against the organisms tested: Staphylococcus aureus, Staphylococcus epidermidis, Klebsiellapneumoniae, Enterococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, Acinetobacter calcoaceticus, Corynebacterium diphtheriae,Enterobacter aerogenes, GMRSa, Pseudomonas aeruginosa, Candida glabrata and VRE (Enterococcus faecium).

** All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated withAMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.

† Decreases viable microbe count on surface of product during handling and placement.

All model numbers with “CDC” contain ChloraPrep retractable safety scalpel, needle locking devices and double sterile barrier with CSR wrap.

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Advan

cedMinim

allyInvasive

Hem

odyn

amicMonito

ring

PreSep Oximetry Catheters

PreSep oximetry catheters are triple lumen central venous catheters with the added capability for continuously

monitoring central venous oxygen saturation (ScvO2). It is integral to Early Goal-Directed Therapy (EGDT)

for the management of sepsis. EGDT when used with the PreSep catheter yields significant reductions in

sepsis-related mortality1.

• Continuous ScvO2 monitoring to assess the balance of oxygen delivery and consumption.

• Available with antimicrobial protection using Oligon material.*

• Easy to insert using same insertion technique as that of central lines.

• Pressure monitoring and high flow rates.

• Compatible with Edwards oximetry monitors and optical module.

Integrated AntimicrobialModel Description Protection* Size (F) # Lumens Length (cm)

X3820HKCDC PreSep oximetry catheter CDC kit** N 8.5 3 20

X3820KCDC PreSep oximetry catheter CDC kit N 8.5 3 20

X3816HKCDC PreSep oximetry catheter CDC kit** N 8.5 3 16

X3816KCDC PreSep oximetry catheter CDC kit N 8.5 3 16

XA3820HKCDC PreSep Oligon oximetry catheter CDC kit** Y 8.5 3 20

XA3820KCDC PreSep Oligon oximetry catheter CDC kit Y 8.5 3 20

XA3816HKCDC PreSep Oligon oximetry catheter CDC kit** Y 8.5 3 16

XA3816KCDC PreSep Oligon oximetry catheter CDC kit Y 8.5 3 16

XA3816HKSAF PreSep Oligon oximetry catheter safety kit** Y 8.5 3 16

XA3816KSAF PreSep Oligon oximetry catheter safety kit Y 8.5 3 16

XA3820HKSAF PreSep Oligon oximetry catheter safety kit** Y 8.5 3 20

XA3820KSAF PreSep Oligon oximetry catheter safety kit Y 8.5 3 20

Proximal Lumen

Distal Lumen

Medial Lumen

Suture Ring

Suture Wings

Sheath

Optical ModuleConnector

Page 6: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

3

* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated withAMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.

† Decreases viable microbe count on surface of product during handling and placement.

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

AdvancedMinim

allyInvasive

Hem

odyn

amicMonitoring

PediaSat Oximetry Catheters

PediaSat oximetry catheters are pediatric central venous catheters with the added capability for

continuously monitoring central venous oxygen saturation (ScvO2).

• Continuously monitors ScvO2 to assess the balance of oxygen delivery and consumption.

• Sized for pediatrics.

• Easy to insert using same insertion technique as that of central lines.

• Offers high flow rates and convenient administration of fluids.

• Compatible with Edwards optical module and Edwards monitors including:

Vigileo, Vigilance II and Explorer monitors and SAT-2 device.

PediaSat Triple Lumen Catheters

Model Description Size (F) Unit of Measure Length (cm)

XT358HK PediaSat oximetry catheter kit* 5.5 3 8

XT358K PediaSat oximetry catheter kit 5.5 3 8

XT3515HK PediaSat oximetry catheter kit* 5.5 3 15

XT3515K PediaSat oximetry catheter kit 5.5 3 15

PediaSat Double Lumen Catheters

Model Description Size (F) # Lumens Length (cm)

XT245HK PediaSat oximetry catheter kit* 4.5 2 5

XT245K PediaSat oximetry catheter kit 4.5 2 5

XT248HK PediaSat oximetry catheter kit* 4.5 2 8

XT248K PediaSat oximetry catheter kit 4.5 2 8

Page 7: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

4

Advan

cedMinim

allyInvasive

Hem

odyn

amicMonito

ring

Vigileo Monitor

Vigileo monitor is a single monitor solution for fluid optimization and tissue oxygenation. It allows for

the continuous monitoring of essential hemodynamic information, providing rapid insight on a minimally

invasive, easy-to-use platform.

The Vigileo monitor works with:

• The FloTrac sensor to measure and display key flow parameters (CO, SV, SVV, SVR).

• The PreSep catheter to provide central venous oxygen saturation (ScvO2).

Model Description

MHM1 Vigileo monitor (110 V)

MHM1E Vigileo monitor (220 V)

MHAPLMNT Vigileo monitor pole mount kit

TM

?

ViVigileogileoTM

ScvO2

ScvO2CO100

50

0

12

6

0

74

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Page 8: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

Thermal FilamentConnector

Thermistor Connector

Balloon Inflation Valve

Thermistor@ 4 cm

Balloon

Thermal Filament

PA DistalLumen

VIP Port @ 30 cm

Proximal InjectatePort @ 26 cm

Proximal InjectateLumen Hub

VIP Lumen Hub

PA Distal Lumen Hub

Optical ModuleConnector

Advanced Hemodynamic Monitoring

Model Description Size (F) Unit of Measure Length (cm)

139F75 Continuous cardiac output (CCO) VIP catheter 7.5 CS (5) 110

139HF75P Continuous cardiac output (CCO) VIP catheter* 7.5 CS (5) 110

Swan-Ganz CCO Catheters

Swan-Ganz continuous cardiac output, SvO2 and CEDV catheters are to be used with the Vigilance II monitor

to properly display the specified parameters. Swan-Ganz CCO catheters allow for continuous calculation

of cardiac output.

Swan-Ganz CCOmbo Catheters

Swan-Ganz CCOmbo catheters are the abbreviated name for Swan-Ganz CCO/SvO2 thermodilution catheters,

which are designed to continuously monitor both cardiac output and mixed venous oxygen saturation (SvO2).

Model Description Size (F) Unit of Measure Length (cm)

744F75 Continuous cardiac output catheter with SvO2 7.5 EA 110

744HF75 Continuous cardiac output catheter with SvO2* 7.5 EA 110

746F8 Continuous cardiac output VIP catheter with SvO2 8 EA 110

746HF8 Continuous cardiac output VIP catheter with SvO2* 8 EA 110

Swan-Ganz Combo V Catheters

Swan-Ganz CCOmbo V catheters are designed to enable continuous monitoring of hemodynamic pressures,

continuous cardiac output, mixed venous oxygen saturation (SvO2), and continuous end diastolic volume (EDV).

Model Description Size (F) Unit of Measure Length (cm)

774F75 Continuous cardiac output catheter with SvO2 and EDV 7.5 EA 110

774HF75 Continuous cardiac output catheter with SvO2 and EDV* 7.5 EA 110

777F8 Continuous cardiac output VIP catheter with SvO2 and EDV 8 EA 110

777HF8 Continuous cardiac output VIP catheter with SvO2 and EDV* 8 EA 110

* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated withAMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.

† Decreases viable microbe count on surface of product during handling and placement.

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Advanced

Hem

odyn

amicMonitoring

5

Page 9: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated withAMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.

† Decreases viable microbe count on surface of product during handling and placement.

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Swan-Ganz Oximetry Thermodilution Catheters

Swan-Ganz oximetry thermodilution catheters continuously monitor mixed venous oxygen saturation.

• Swan-Ganz oximetry thermodilution catheters enable monitoring of hemodynamic pressures,

cardiac output, and continuous mixed venous oxygen saturation.

• Swan-Ganz VIP oximetry thermodilution catheters provide an additional (VIP) lumen that

allows for continuous infusion.

• Swan-Ganz Paceport oximetry thermodilution catheters are intended for use in patients who

require hemodynamic monitoring when temporary transvenous pacing is anticipated.

Model Description Size (F) Unit of Measure Length (cm)

741F75 Oximetry thermodilution catheter 7.5 EA 110

741HF75 Oximetry thermodilution catheter* 7.5 EA 110

782HF75 VIP oximetry thermodilution catheter* 7.5 EA 110

780HF75 Paceport oximetry thermodilution catheter* 7.5 EA 110

631HF55 Pediatric oximetry thermodilution catheter* 5.5 EA 75

040F4 Small French oximetry catheter 4 EA 40

040HF4 Small French oximetry catheter* 4 EA 40

015F4 Small French oximetry catheter 4 EA 25

015HF4 Small French oximetry catheter* 4 EA 25

Thermistor Connector

Distal LumenHub

Proximal InjectateLumen Hub

Balloon Inflation ValveOptical ModuleConnector

RV PaceportLumen Hub(Pacing/Infusion)

RV Port @ 19 cm

Proximal InjectatePort @ 30 cm

Thermistor

Distal Lumen

Balloon

6

Advan

cedHem

odyn

amicMonito

ring

Page 10: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

7

Advanced

Hem

odyn

amicMonitoring

* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated withAMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.

† Decreases viable microbe count on surface of product during handling and placement.

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Swan-Ganz Thermodilution Pacing Catheters

Swan-Ganz thermodilution pacing catheters are indicated for atrial, ventricular, or A-V sequential pacing.

• Thermodilution pacing catheters contain three atrial and two ventricular electrodes for atrial

and ventricular pacing and atrioventricular (A-V) sequential pacing.

Model Description Size (F) Unit of Measure Length (cm)

D200F7 Pacing-TD catheter 7 EA 110

D200HF7 Pacing-TD catheter* 7 EA 110

D205HF7 Pacing-TD catheter, for smaller hearts* 7 EA 110

Swan-Ganz Paceport Catheters and Chandler Probes

Swan-Ganz Paceport catheters are intended for use in patients who require hemodynamic monitoring

when the need for temporary transvenous pacing is anticipated.

Model Description Size (F) Unit of Measure Length (cm)

931F75 Paceport TD five lumen catheter 7.5 EA 110

931HF75 Paceport TD five lumen catheter* 7.5 EA 110

991HF8 A-V Paceport six lumen catheter* 8 EA 110

D98100H Chandler transluminal V-pacing probe* 2.4 EA 135

D98500H Flex-Tip transluminal A-pacing probe* 2.4 EA 135

Thermistor Connector

PA DistalLumen Hub Proximal Injectate Hub

Balloon Inflation Valve

Proximal InjectatePort @ 30 cm

Thermistor

PA Distal Lumen

Balloon

RV Port @ 19 cmRV Paceport Lumen Hub(Pacing/Infusion)

Paceport Catheter

Page 11: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

Gate Valve

Distal Electrode Connector

Proximal Electrode

Distal Electrode

Balloon

ProximalElectrodeConnector

Swan-Ganz Bipolar Pacing Catheters

Swan-Ganz bipolar pacing catheters are designed for temporary right ventricular endocardial pacing.

Model Description Size (F) Unit of Measure Length (cm)

D97120F5 SVC insertion, catheter only 5 EA 90

D97130F5 Femoral insertion, catheter only, “J-Tip” 5 EA 90

D97K12F5 SVC insertion, kit, 5 EA 90

D97K13F5 Femoral insertion, kit, “J-Tip” 5 EA 90

D97140HF5 VIP kit* 5 EA 100

* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated withAMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.

† Decreases viable microbe count on surface of product during handling and placement.

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

8

Advan

cedHem

odyn

amicMonito

ring

Page 12: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

9

Advanced

Hem

odyn

amicMonitoring

* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated withAMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.

† Decreases viable microbe count on surface of product during handling and placement.

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Swan-Ganz Thermodilution Catheters

Swan-Ganz thermodilution catheters are designed for a variety of hemodynamic applications.

Model Description Size (F) Unit of Measure Length (cm)

132F5 Four lumen catheter 5 EA 75

096F6P Four lumen catheter 6 CS (5) 110

131F7 Standard four lumen catheter 7 CS (5) 110

131HF7 Standard four lumen catheter* 7 CS (5) 110

Swan-Ganz VIP & VIP+ Catheters

The Swan-Ganz thermodilution catheters are designed for a variety of hemodynamic applications.

• The Swan-Ganz VIP catheters have an extra lumen in addition to the standard distal and injectate

lumens to provide direct access to the right atrium.

• The Swan-Ganz VIP+ catheters are equipped with two right atrium lumens.

Model Description Size (F) Unit of Measure Length (cm)

831F75 VIP five lumen catheter 7.5 CS (5) 110

831HF75 VIP five lumen catheter* 7.5 CS (5) 110

834HF75 VIP+ six lumen catheter* 7.5 CS (5) 110

ThermistorConnector

Proximal InjectateLumen Hub

PA DistalLumen Hub

Balloon InflationValve (Gate Valve)

Proximal InjectatePort @ 30 cm

Thermistor

Balloon

PA DistalLumen

RA Infusion Lumen

RV Infusion Lumen HubRA InfusionPort @ 31 cm

RV InfusionPort @ 19 cm

Page 13: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

1 0

Advan

cedHem

odyn

amicMonito

ring

Swan-Ganz No Latex Catheter and Introducer

• Catheter and introducer sheath are packaged together for maximum convenience.

• ControlCath thermodilution catheters are made from a proprietary polymer blend and offer improved

torque control and maneuverability over the standard Swan-Ganz thermodilution catheter.

• The Swan-Ganz ControlCath synthetic thermodilution catheter “C-Tip” allows for both femoral

or SVC approaches.

• K9FC146F7 contains catheter model C146F7 and introducer model I505BF9.

Model Description Size (F) Unit of Measure Length (cm)

K9FC146F7 No latex catheter and introducer 7 EA 110

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Thermistor Connector

Distal Lumen Hub

Injectate Lumen Hub

Balloon Inflation Valve

ProxiPort @

“C-Tip”

Proximal InjectatePort @ 30 cm

Thermistor

Distal Lumen Port

Balloon

Page 14: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

1 1

Advanced

Hem

odyn

amicMonitoring

* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated withAMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.

† Decreases viable microbe count on surface of product during handling and placement.

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Swan-Ganz Femoral Vein Insertion Catheters

Swan-Ganz thermodilution catheters are designed for a variety of hemodynamic applications.

• Swan-Ganz Hi-Shore thermodilution catheters are slightly stiffer than the standard Swan-Ganz

catheter, and may be used when more torque control and maneuverability is needed.

• Swan-Ganz CardioCath thermodilution catheters are made of the same material as the Hi-Shore

catheters, but are even stiffer due to the stiffening rod in one lumen.

• Swan-Ganz ControlCath thermodilution catheters are made from a proprietary polymer blend

and offer improved torque control and maneuverability.

• The “S-Tip” configuration is designed specifically for femoral vein insertion.

• The “C-Tip” configuration allows for both femoral or SVC approaches.

Model Description Size (F) Unit of Measure Length (cm)

141HF7 Hi-Shore catheter* 7 CS (5) 110

141F7 Hi-Shore catheter 7 CS (5) 110

151F7 “S-Tip” catheter 7 EA 110

151HF7 “S-Tip” catheter* 7 EA 110

143HTF7 CardioCath, Hi-Shore catheter* 7 EA 110

143TF7 CardioCath, Hi-Shore catheter 7 EA 110

C144F7 ControlCath catheter, polymer blend, “C-Tip” 7 EA 110

C144HF7 ControlCath catheter, polymer blend, “C-Tip”* 7 EA 110

C145HF6 ControlCath catheter, polymer blend, “C-Tip”* 6 EA 110

S144F7 ControlCath catheter, polymer blend, “S-Tip” 7 EA 110

S144HF7 ControlCath catheter, polymer blend, “S-Tip”* 7 EA 110

Thermistor Connector

Distal Lumen Hub

Injectate Lumen Hub

Balloon Inflation Valve

Proximal InjectatePort @ 30 cm

Thermistor

Distal Lumen Port

Balloon

“S-Tip”

Proximal InjectatePort @ 30 cm

Thermistor

Distal Lumen Port

Balloon

“C-Tip”

Page 15: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

1 2

Swan-Ganz Pulmonary Angiography Catheters

Swan-Ganz pulmonary angiography catheters are indicated for the detection of emboli in the

pulmonary vasculature.

• The distal tip is closed-ended to optimize injection of contrast medium through the

multi-hole side exit ports, which minimizes the occurrence of arrhythmias, intramyocardial

staining, and catheter tip recoil.

Model Description Size (F) Unit of Measure Length (cm)

191F7 Pulmonary angiography catheter 7 EA 110

191HF7 Pulmonary angiography catheter* 7 EA 110

191F8 Pulmonary angiography catheter 8 EA 110

191HF8 Pulmonary angiography catheter* 8 EA 110

* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated withAMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.

† Decreases viable microbe count on surface of product during handling and placement.

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Advan

cedHem

odyn

amicMonito

ring

Balloon Inflation Valve

Proximal Injection Ports

Balloon

Proximal Lumen Hub

Page 16: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

1 3

Advanced

Hem

odyn

amicMonitoring

Swan-Ganz Monitoring Catheters

Swan-Ganz flow-directed monitoring catheters provide a rapid, simple, and effective method for

monitoring right heart pressures.

• In double lumen catheters, the lumen terminates at the distal tip of the catheter and is

used to monitor pulmonary artery and wedge pressures.

• Triple lumen monitoring catheters have the same capabilities as double lumen catheters

with the additional (proximal) lumen for central venous pressure monitoring.

Model Description Size (F) Unit of Measure Length (cm)

110F5 Double lumen catheter 5 CS (5) 110

123F6P Double lumen catheter 6 CS (5) 110

T123F6 Double lumen catheter, “T-Tip” 6 CS (5) 110

111F7P Double lumen catheter 7 CS (5) 110

S111F7 Double lumen catheter, “S-Tip” bend 7 EA 110

T111F7 Double lumen Hi-Shore catheter, “T-Tip” 7 CS (5) 110

114F7P Triple lumen catheter, 30 cm exit proximal lumen 7 CS (5) 110

115F7P Triple lumen catheter, 20 cm exit proximal lumen 7 CS (5) 110

Balloon Inflation Valve

Distal LumenHub

PA Distal Lumen Port

Balloon

Proximal Lumen Hub

Triple Lumen Monitoring Catheter

Proximal Lumen Port

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Page 17: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

1 4

Advan

cedHem

odyn

amicMonito

ring

CO-Set+ Closed Injectate Delivery System

The CO-Set+ closed injectate delivery system works effectively with room temperature or cold injectate.

• Provides simple and convenient delivery of injectate for the measurement of cardiac

output by thermodilution.

• Includes a 10 cc syringe with integrated contamination shield.

Model Description Unit of Measure

93600 Cold injectate system CS (10)

93610 Room temperature injectate system CS (10)

93611 Room temperature injectate system with 2 bonded stopcocks CS (8)

CO-Set+ System Component Parts

Model Description Unit of Measure

93505 Flow-through injectate housing CS (8)

93520 Cooling containers CS (6)

93521 Cooling container bracket for IV pole EA

93522 CO-Set+ system inline injectate temperature probe for Edwards monitors EA

93650 CO-Set+ system syringe, 10 cc CS (5)

10 cc Syringe

Cooling Container

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Page 18: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

1 5

Advanced

Hem

odyn

amicMonitoring

IntroFlex Percutaneous Sheath Introducers

IntroFlex introducers are the perfect companion for your Swan-Ganz catheters.

• Sheath material resists kinking and sheath collapse, while easing insertion.

• Improved taper for easier insertion.

• Adjustable locking device helps secure catheter in place.

• Available with or without AMC Thromboshield* coating, an antimicrobial† heparin coating.

5 French Introducers

Model Description Unit of Measure Useable Length (cm)

I500F5C Kit with 5F sheath, detachable automatic CS (10) 10

valve and ChloraPrep preoperative skin

preparation sites

I550BF5 Kit with 5F sheath and bonded adjustable valve CS (10) 10

6 French Introducers

Model Description Unit of Measure Useable Length (cm)

I500F6C Kit with 6F sheath, detachable automatic CS (10) 10

valve and ChloraPrep preoperative skin

preparation sites

I550BF6 Kit with 6F sheath and bonded adjustable valve CS (10) 10

7 French Introducers

Model Description Unit of Measure Useable Length (cm)

I500F7C Kit with 7F sheath, detachable automatic CS (10) 10

valve and ChloraPrep preoperative skin

preparation sites

I550BF7 Kit with 7F sheath and bonded adjustable valve CS (10) 10

Tissue

Catheter

Sideport

SheathIntroducer Valve Housing

Distal Locking Adapter

Touhy-Borst Proximal Adapter

Contamination Shield

Strain Relief

* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated withAMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.

† Decreases viable microbe count on surface of product during handling and placement.

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Page 19: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated withAMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.

† Decreases viable microbe count on surface of product during handling and placement.

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

1 6

8 French Introducers

Model Description Unit of Measure Useable Length (cm)

I550BF8 Kit with 8F sheath and bonded adjustable valve CS (10) 10

8.5 French Introducers

Model Description Unit of Measure Useable Length (cm)

I500F85C Kit with 8.5F sheath, detachable automatic CS (10) 10

valve and ChloraPrep preoperative skin

preparation sites

I500BF85 Kit with 8.5F sheath, bonded automatic valve CS (10) 10

I500BF85C Kit with 8.5F sheath, bonded automatic valve CS (10) 10

and ChloraPrep preoperative skin preparation sites

SI500BF85I Safety kit with ChloraPrep preoperative skin CS (10) 10

preparation, SafetyGlide needles, Futura safety

scalpel and CLC 2000 connector

I502BF85HC Kit with 8.5F heparin coated sheath, bonded CS (10) 10

automatic valve and ChloraPrep preoperative skin

preparation sites*

I551BF85H Kit with 8.5F heparin coated sheath and bonded CS (10) 10

adjustable valve*

9 French Introducers: High-Flow Sidearm

Model Description Unit of Measure Useable Length (cm)

I505BF9HC High-flow kit with 9F heparin coated sheath, CS (10) 10

bonded automatic valve and ChloraPrep

preoperative skin preparation sites*

I555BF9H High-flow kit with 9F heparin coated sheath, CS (10) 10

bonded adjustable valve*

SI5AB9FKI Safety kit with ChloraPrep preoperative skin CS (10) 10

preparation, SafetyGlide needles, Futura safety

scalpel and CLC 2000 connectorCompreh

ensive

Hem

odyn

amic

Monito

ring

Page 20: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

Comprehen

sive

Hem

odyn

amic

Monitoring

1 7

Vigilance II Monitor

The Vigilance II monitor offers a complete picture of hemodynamic performance.

• CO, SvO2, EDV, RVEF, SVR and SV parameters are continuously displayed on a single,

easy-to-use unit.

• Calculation and cross-correlation of hemodynamic and oxygenation parameters provide a rapid,

comprehensive diagnosis.

• Pseudorandom signal processing.

• STAT mode provides up-to-the-minute hemodynamic assessment.

• Trended indexed or non-indexed parameters are available at the touch of a button.

• Service and extended warranties are available for the Vigilance II monitor. For more information

please speak with an Edwards sales representative or call 800-822-9837.

Model Description

VIG2 Continuous cardiac output computer system with SvO2 and CEDV capabilities

Vigilance II Monitor Accessories

Model Description Unit of Measure

70CC2 Vigilance monitor patient CCO cable EA

93522 In-line injectate temperature probe EA

COM2PC Power cord EA

OM2 Oximetry optical module EA

9850A Bath temperature probe EA

TM

min

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Page 21: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

1 8

Pressure

Monito

ringan

dClosed

BloodSam

plin

gSystem

s

Pressure Monitoring and Closed Blood Sampling Systems

TruWave Disposable Pressure Transducers

The pressure monitoring kit with the TruWave disposable pressure transducer is a sterile, single-use

kit that monitors blood pressure when attached to pressure monitoring catheters.

• Design features a straight, flow-through design across the pressure sensor.

• Available with or without the integral flush device.

• Designed with a snap-tab device for square-wave testing.

TruWave Disposable Pressure Transducers

Model Description Unit of Measure

PX600 TruWave disposable pressure transducer, one bonded 1-way shutoff stopcock CS (20)

PX600F TruWave disposable pressure transducer, 3 ml/hr flush device, vent stopcock CS (20)

PX600F30 TruWave disposable pressure transducer, 30 ml/hr flush device, vent stopcock CS (20)

PX600I TruWave disposable pressure transducer, bonded 1-way shutoff stopcock, CS (20)

bonded 3-way vent stopcock

PX601 TruWave disposable pressure transducer, 12” cable CS (20)

PX604 TruWave disposable pressure transducer, 4’ cable CS (20)

PX604I TruWave disposable pressure transducer, 4’ cable, bonded CS (10)

1-way shutoff stopcock, bonded 3-way vent stopcock

Transducer Vent Port

Snap-Tab Device

To Monitor

ToIV Set

Test PortTo Patient

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Page 22: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

1 9

Pressure

Monitoringan

dClosedBloodSamplin

gSystem

s

TruWave Disposable Pressure Transducer Kits

Model Description Unit of Measure

PX212 Model PX600F disposable pressure transducer, flush device, IV set CS (10)

(macrodrip), 12” pressure tubing, one 3-way stopcock

PX260 Model PX600F disposable pressure transducer, flush device, CS (10)

IV set (macrodrip), 48” and 12” pressure tubing, two 3-way stopcocks

PX272 Model PX600F disposable pressure transducer, flush device, IV set CS (10)

(macrodrip), 60” and 12” pressure tubing, two 3-way stopcocks

PX284 Model PX600F disposable pressure transducer, flush device, IV set CS (10)

(macrodrip), 72” and 12” pressure tubing, two 3-way stopcocks

PX1X2 Model PX600F disposable pressure transducer, two flush devices, CS (10)

bifurcated IV set (macrodrip), two sets of 48” and 12” pressure tubing,

three 3-way stopcocks, one 4-way stopcock

PX2X2 Model PX600F disposable pressure transducer, two flush devices, CS (10)

bifurcated IV set (macrodrip), two sets of 48” and 12” pressure

tubing, four 3-way stopcocks

PX2X3 Two model PX600F disposable pressure transducers, three flush CS (10)

devices, trifurcated IV set (macrodrip), three sets of 48” and 12”

pressure tubing, five 3-way stopcocks, one 4-way stopcock

PX3X3 Three model PX600F disposable pressure transducers, three flush devices, CS (10)

trifurcated IV set (macrodrip), three sets of 48” and 12” pressure tubing,

six 3-way stopcocks

PX3X3272 Three model PX600F disposable pressure transducers, three flush devices, CS (10)

trifurcated IV set (macrodrip), three sets of 60” and 12” pressure tubing,

six 3-way stopcocks

TruWave Disposable Pressure Transducer Pediatric Neonatal Kits

Model Description Unit of Measure

PX12N TruWave disposable pressure transducer, 30 cc flush device, CS (10)

12” pediatric tubing, two 3-way stopcocks

PX24N TruWave disposable pressure transducer, 30 cc flush device, CS (10)

24” pediatric tubing, two 3-way stopcocks

PX36N TruWave disposable pressure transducer, 30 cc flush device, CS (10)

36” pediatric tubing, two 3-way stopcocks

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Page 23: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

2 0

Pressure

Monito

ringan

dClosed

BloodSam

plin

gSystem

s

VAMP Closed Blood Sampling System

Venous Arterial blood Management Protection system is a needleless closed blood sampling system.

• When attached to pressure monitoring lines, the VAMP system provides a safe and convenient

method for the withdrawal of blood samples.

• Designed for use with all disposable pressure transducers and for connection to central line

catheters and arterial catheters.

• Versatile design can be bracket mounted on an IV pole or used as an arm-mount depending

on the application.

• A needleless sampling port.

VAMP System Kits

Model Description Unit of Measure

VMP106 6” sampling kit, sample site, reservoir and two shut-off valves (may CS (20)

be used for venous applications without a flow controlling device)

48VMP120 20” sampling kit, sample site and arm reservoir CS (20)

48VMP160 60” sampling kit, sample site and arm reservoir CS (20)

48VMP172 72” sampling kit, sample site and arm reservoir CS (20)

48VMP184 84” sampling kit, sample site and arm reservoir CS (20)

48VMP260 60” sampling kit, sample site and pole-mount reservoir CS (20)

48VMP272 72” sampling kit, sample site and pole-mount reservoir CS (20)

48VMP284 84” sampling kit, sample site and pole-mount reservoir CS (20)

48AVMP VAMP system anesthesia kit, 68” sampling kit with male/female connector CS (20)

Proximal(To Patient)

SamplingSite

Shut Off ValveReservoir

Distal

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Page 24: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

2 1

Pressure

Monitoringan

dClosedBloodSamplin

gSystem

s

VAMP Plus System Kits

Venous Arterial blood Management Protection Plus system allows the withdrawal of blood samples from

pressure monitoring lines.

• Designed for use with disposable pressure transducers and for connection to central line catheters,

venous catheters, and arterial catheters where the system can be flushed clear after sampling.

• One-handed pole-mount provides a simple method of drawing the clearing volume.

• Blood sample sites incorporate familiar needleless technology for added safety.

Model Description Unit of Measure

VP1 VAMP Plus system reservoir with 60” patient tubing and one sample site CS (10)

located 55” from the patient

VP2 VAMP Plus system reservoir with 60” patient tubing and two sample sites CS (10)

located 13” and 55” from the patient

VAMP System Accessories

Model Description Unit of Measure

VMP400 VAMP system needleless cannula CS (200)

VMP503H 3 cc heparin coated ABG syringe with VAMP needleless cannula* CS (50)

48VMP600 VAMP system blood transfer unit (BTU) for sample transfer to vacuum tubes CS (50)

VMP700 VAMP system direct draw unit for direct line blood sampling CS (50)

12 cc Reservoir

Shut Off Valve

Dual Sampling Sites

* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated withAMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.

† Decreases viable microbe count on surface of product during handling and placement.

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Page 25: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

2 2

Pressure

Monito

ringan

dClosed

BloodSam

plin

gSystem

s

VAMP Jr. System Kits

The VAMP Jr. closed blood sampling system provides a safe and convenient method for withdrawing

blood samples.

• Designed for connection to umbilical, arterial, and central line catheters and for use with

disposable and reusable pressure transducers, if desired.

• The VAMP Jr. reservoir is used for drawing and retaining diluted blood (or clearing volume)

from an in-line sampling site.

Model Description Unit of Measure

VMP306 2” proximal, 4” distal for neonatal application CS (20)

VMP406 3” proximal, 3” distal for pediatric application CS (20)

VMP426 10” proximal, 16” distal for pediatric application CS (20)

VMP448 19” proximal, 29” distal for pediatric application CS (20)

2cc

1cc

Proximal(To Patient)

Needle*LessSampling Site

Needle*LessAccess/Flush Site

Shut-O!Valve

Shut-O!Valve

Reservoir

Distal

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Page 26: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

2 3

Pressure

Monitoringan

dClosedBloodSamplin

gSystem

s

TruWave Transducers/VAMP System Combination Kits

Model Description Unit of Measure

PXVMP120 20” VAMP system with arm-mount reservoir with CS (10)

TruWave disposable pressure transducer

PXVMP160 60” VAMP system with arm-mount reservoir with CS (10)

TruWave disposable pressure transducer

PXVMP172 72” VAMP system with arm-mount reservoir with CS (10)

TruWave disposable pressure transducer

PXVMP184 84” VAMP system with arm-mount reservoir with CS (10)

TruWave disposable pressure transducer

PXVMP260 60” VAMP system with arm-mount reservoir with CS (10)

TruWave disposable pressure transducer

PXVMP272 72” VAMP system with arm-mount reservoir with CS (10)

TruWave disposable pressure transducer

PXVMP284 84” VAMP system with arm-mount reservoir with CS (10)

TruWave disposable pressure transducer

PXVMP2X21 60” VAMP system with arm-mount reservoir on the arterial line with two CS (10)

TruWave disposable pressure transducers with two 3 ml/hr flush devices,

bifurcated IV set (macrodrip), one set of 48” and 12” pressure tubing,

three 3-way stopcocks

PXVMP2X22 60” VAMP system with pole-mount reservoir on the arterial line with two CS (10)

TruWave disposable pressure transducers with two 3 ml/hr flush devices,

bifurcated IV set (macrodrip), one set of 48”and 12” pressure tubing,

three 3-way stopcocks

PXVMP2X31 60” VAMP system with arm-mount reservoir on the arterial line with two CS (10)

TruWave disposable pressure transducers with two 3 ml/hr flush devices,

trifurcated IV set (macrodrip), pressure selection stopcocks, two sets of 48”

and 12” pressure tubing, five 3-way stopcocks

PXVMP3X31 60” VAMP system with arm-mount reservoir on the arterial line with three CS (10)

TruWave disposable pressure transducers with three 3 ml/hr flush devices,

trifurcated IV set (macrodrip), two sets of 48” and 12” pressure tubing,

five 3-way stopcocks

PXVMP3X32 72” VAMP system with pole-mount reservoir on the arterial line with three CS (10)

TruWave disposable pressure transducers with three 3 ml/hr flush devices,

trifurcated IV set (macrodrip), two sets of 60” and 12” pressure tubing,

five 3-way stopcocks

PXAVMP VAMP sampling kit with TruWave disposable pressure transducer, CS (10)

68” total tubing, male connector

PXAVMP3 VAMP sampling kit with three TruWave disposable pressure transducers, CS (10)

68” total tubing, male connector

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Page 27: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

2 4

Pressure

Monito

ringan

dClosed

BloodSam

plin

gSystem

s

TruWave Transducers/VAMP Plus System Combination Kits

Model Description Unit of Measure

PXVP2260 TruWave disposable pressure transducer/VAMP Plus system kit with 60” CS (10)

patient tubing and two sample sites located 13” and 55” from the patient

PXVP2272 TruWave disposable pressure transducer/VAMP Plus system kit with 72” CS (10)

patient tubing and two sample sites located 13” and 55” from the patient

PXVP2284 TruWave disposable pressure transducer/VAMP Plus system kit with 84” CS (10)

patient tubing and two sample sites located 13” and 55” from the patient

PXVP23X3 TruWave disposable pressure transducer/VAMP Plus system kit with three CS (10)

TruWave transducers, 60” patient tubing and two sample sites located 13”

and 55” from the patient

TruWave Transducers/VAMP Jr. System Combination Kits

Model Description Unit of Measure

VMP306PX 30 cc TruWave disposable pressure transducer, with 2” proximal, 4” distal CS (10)

VAMP Jr. system for neonatal application

VMP406PX 3 cc TruWave disposable pressure transducer, with 3” proximal, 3” distal CS (10)

VAMP Jr. system for pediatric application

VMP426PX 3 cc TruWave disposable pressure transducer, with 10” proximal, 16” distal CS (10)

VAMP Jr. system for pediatric application

VMP448PX 3 cc TruWave disposable pressure transducer, with 29” proximal, 18” distal CS (10)

VAMP Jr. system for pediatric application

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Page 28: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

2 5

Pressure

Monitoringan

dClosedBloodSamplin

gSystem

s

TruWave Disposable Pressure Transducer Accessories

Model Description Unit of Measure

DTH4 Backplate holder for disposable pressure transducers CS (10)

DTSC IV pole clamp for model DTH4 backplate holder EA

DTSS Arm strap for model PX-series disposable pressure transducer CS (10)

AM300 Adhesive body mount for disposable pressure transducer CS (100)

59PXCAL TruCal pressure transducer simulator for TruWave disposable EA

pressure transducers

PHYSIOTRAC PhysioTrac laser leveler EA

PXSIM Pressure transducer simulator tester tubing set for TruWave EA

disposable pressure transducer used in conjunction with 59PXCAL

PX1800 Reusable cable for use with TruWave disposable pressure transducers EA

(monitor information must be specified when ordering)

TruWave Disposable Pressure Transducer Arterial Turnarounds

Model Description Unit of Measure

1WV06 6” pressure tubing, low volume, bonded to 1-way stopcock CS (20)

K16906 6” pressure tubing, low volume, bonded to 3-way stopcock CS (20)

K16912 12” pressure tubing, low volume, bonded to 3-way stopcock CS (20)

TruWave Disposable Pressure Transducer Continuous Flush Devices

Model Description Unit of Measure

55UF100 Flush device, flow rate 3 ml/hr CS (20)

55UF130 Flush device, flow rate 30 ml/hr CS (20)

TruWave Disposable Pressure Transducer IV Sets

Model Description Unit of Measure

54IV12 Single line macrodrip IV set with 60” main line CS (10)

54IV22 Bifurcated macrodrip IV set with 36” main line and 9” extension legs CS (10)

IV32 Trifurcated macrodrip IV set with 36” main line and 9” extension legs CS (20)

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Page 29: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

2 6

Pressure

Monito

ringan

dClosed

BloodSam

plin

gSystem

s

TruWave Disposable Pressure Transducer Accessories

Model Description Unit of Measure

50P106 Male/female connectors, 6” long CS (20)

50P112 Male/female connectors, 12” long CS (20)

50P124 Male/female connectors, 24” long CS (20)

50P136 Male/female connectors, 36” long CS (20)

50P148 Male/female connectors, 48” long CS (20)

50P160 Male/female connectors, 60” long CS (20)

50P172 Male/female connectors, 72” long CS (20)

50P184 Male/female connectors, 84” long CS (20)

50P200R Male/male luer lock adapter with rotating nut CS (20)

50P206 Male/male connectors, 6” long CS (20)

50P212 Male/male connectors, 12” long CS (20)

50P224 Male/male connectors, 24” long CS (20)

50P236 Male/male connectors, 36” long CS (20)

50P248 Male/male connectors, 48” long CS (20)

50P260 Male/male connectors, 60” long CS (20)

50P272 Male/male connectors, 72” long CS (20)

50P284 Male/male connectors, 84” long CS (20)

TruWave Disposable Pressure Transducer Stopcocks and Caps

Model Description Unit of Measure

1WSC One-way sterile stopcock CS (50)

3WSC Three-way sterile stopcock CS (50)

4WSC Four-way sterile stopcock CS (50)

59L3WSC Lipid resistant 3-way stopcock CS (20)

59L4WSC Lipid resistant 4-way stopcock CS (20)

MNVC Sterile, non-vented male cap CS (50)

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Page 30: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

2 7

* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated withAMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.

† Decreases viable microbe count on surface of product during handling and placement.

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Pediatric

Hem

odyn

amicMonitoring

Pediatric Hemodynamic Monitoring

PediaSat Oximetry Catheters

PediaSat oximetry catheters are pediatric central venous catheters with the added capability for the

continuous monitoring of central venous oxygen saturation (ScvO2).

• Continuous ScvO2 monitoring to assess the balance of oxygen delivery and consumption.

• Sized for pediatrics.

• Easy to insert using same insertion technique as that of central lines.

• Offers high flow rates and convenient administration of fluids.

• Compatible with Edwards optical module and Edwards monitors including: Vigileo,

Vigilance II and Explorer monitors and SAT-2 device.

PediaSat Triple Lumen Catheters

Model Description Size (F) Unit of Measure Length (cm)

XT358HK PediaSat oximetry catheter kit* 5.5 3 8

XT358K PediaSat oximetry catheter kit 5.5 3 8

XT3515HK PediaSat oximetry catheter kit* 5.5 3 15

XT3515K PediaSat oximetry catheter kit 5.5 3 15

PediaSat Double Lumen Catheters

Model Description Size (F) # Lumens Length (cm)

XT245HK PediaSat oximetry catheter kit* 4.5 2 5

XT245K PediaSat oximetry catheter kit 4.5 2 5

XT248HK PediaSat oximetry catheter kit* 4.5 2 8

XT248K PediaSat oximetry catheter kit 4.5 2 8

Page 31: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

2 8

Pediatric

Hem

odyn

amicMonito

ring

Swan-Ganz Pediatric Catheters

Swan-Ganz pediatric catheters serve as diagnostic tools for the physician to continuously monitor

mixed venous oxygen saturation.

• The Swan-Ganz pediatric catheters enable monitoring of hemodynamic pressures,

cardiac output, and continuous mixed venous oxygen staturation.

Model Description Size (F) Useable Length (cm)

040F4 Small French oximetry catheter 4 40

040HF4 Small French oximetry catheter* 4 40

015F4 Small French oximetry catheter 4 25

015HF4 Small French oximetry catheter* 4 25

Thermistor Connector

Distal LumenHub

Proximal InjectateLumen Hub

Balloon Inflation ValveOptical ModuleConnector

RV PaceportLumen Hub(Pacing/Infusion)

RV Port @ 19 cm

Proximal InjectatePort @ 30 cm

Thermistor

Distal Lumen

Balloon

TruWave Disposable Pressure Transducer Pediatric Neonatal Kits

The pressure monitoring kit with the TruWave disposable pressure transducer is a sterile, single-use kit

that monitors blood pressure when attached to pressure monitoring catheters.

Model Description Unit of Measure

PX12N TruWave disposable pressure transducer, 30 cc flush device, CS (10)

12” pediatric tubing, two 3-way stopcocks

PX24N TruWave disposable pressure transducer, 30 cc flush device, CS (10)

24” pediatric tubing, two 3-way stopcocks

PX36N TruWave disposable pressure transducer, 30 cc flush device, CS (10)

36” pediatric tubing, two 3-way stopcocks

* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated withAMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.

† Decreases viable microbe count on surface of product during handling and placement.

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Page 32: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

2cc

1cc

Proximal(To Patient)

Needle*LessSampling Site

Needle*LessAccess/Flush Site

Shut-O!Valve

Shut-O!Valve

Reservoir

Distal

2 9

Pediatric

Hem

odyn

amicMonitoring

TruWave Transducers/VAMP Jr. System Combination Kits

Model Description Unit of Measure

VMP306PX 30 cc TruWave disposable pressure transducer, with 2” proximal, CS (10)

4” distal VAMP Jr. system for neonatal application

VMP406PX 3 cc TruWave disposable pressure transducer, with 3” proximal, CS (10)

3” distal VAMP Jr. system for pediatric application

VMP426PX 3 cc TruWave disposable pressure transducer, with 10” proximal, CS (10)

16” distal VAMP Jr. system for pediatric application

VMP448PX 3 cc TruWave disposable pressure transducer, with 19” proximal, CS (10)

9” distal VAMP Jr. system for pediatric application

VAMP Jr. Closed Blood Sampling System

The VAMP Jr. closed blood sampling system provides a safe and convenient method for withdrawing

blood samples.

• Designed for connection to umbilical, arterial, and central line catheters and for use with

disposable and reusable pressure transducers, if desired.

• The VAMP Jr. reservoir is used for drawing and retaining diluted blood (or clearing volume)

from an in-line sampling site.

Model Description Unit of Measure

VMP306 2” proximal, 4” distal for neonatal application CS (20)

VMP406 3” proximal, 3” distal for pediatric application CS (20)

VMP426 10” proximal, 16” distal for pediatric application CS (20)

VMP448 19” proximal, 29” distal for pediatric application CS (20)

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Page 33: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

3 0

Cen

tralVen

ousAccess

* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated withAMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.

** Vantex catheters contain an integrated Oligon antimicrobial material. The activity of the antimicrobial material is localized at the catheter surfaces and is notintended for treatment of systemic infections. In vitro testing demonstrated that the Oligon material provided broad-spectrum effectiveness (≥ 3 log reduction frominitial concentration within 48 hours) against the organisms tested: Staphylococcus aureus, Staphylococcus epidermidis, Klebsiella pneumoniae, Enterococcus faecalis,Candida albicans, Escherichia coli, Serratia marcescens, Acinetobacter calcoaceticus, Corynebacterium diphtheriae, Enterobacter aerogenes, GMRSa, Pseudomonasaeruginosa, Candida glabrata and VRE (Enterococcus faecium).

† Decreases viable microbe count on surface of product during handling and placement.

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Central Venous Access

Vantex Central Venous Catheters

Vantex catheters with Oligon** material, are the first central venous catheters made of a biocompatible

and antimicrobial** material.

• The Vantex central venous catheters are the only central venous catheters extruded from

polyurethane, combined with the natural elements of silver, carbon and platinum.

• The Oligon material releases silver ions from the device surfaces, which kills colonizing bacteria.

Vantex Double Lumen Catheters – 7 French

Model Description Size (F) Unit of Measure Length (cm)

A2716HKIC Expanded kit with heparin, Interlink 7 CS (5) 16

injection sites and ChloraPrep preoperative

skin preparation*

SA2716HKI Safety kit with heparin, ChloraPrep preoperative 7 CS (5) 16

skin preparation, SafetyGlide needles, Futura

safety scalpel and CLC 2000 connector*

A2720HKIC Expanded kit with heparin, Interlink 7 CS (5) 20

injection sites and ChloraPrep preoperative

skin preparation*

Proximal Lumen

Distal Lumen

Medial Lumen

Suture Ring

Suture Wings

Sheath

Non-heparin kits also available.

Vantex Double Lumen Catheters – 8.5 French

Model Description Size (F) Unit of Measure Length (cm)

A2816HKIC Expanded kit with heparin, Interlink 8.5 CS (5) 16

injection sites and ChloraPrep preoperative

skin preparation*

A2820HKIC Expanded kit with heparin, Interlink 8.5 CS (5) 20

injection sites and ChloraPrep preoperative

skin preparation*

SA2820HKI Safety kit with heparin, ChloraPrep preoperative 8.5 CS (5) 20

skin preparation, SafetyGlide needles, Futura

safety scalpel and CLC 2000 connector*

Page 34: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

3 1

* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated withAMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.

† Decreases viable microbe count on surface of product during handling and placement.

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Non-heparin kits also available.

Cen

tralVen

ousAccess

Vantex Triple Lumen Catheters – 7 French

Model Description Size (F) Unit of Measure Length (cm)

A3716HKIC Expanded kit with heparin, Interlink 7 CS (5) 16

injection sites and ChloraPrep preoperative

skin preparation*

A3720HKIC Expanded kit with heparin, Interlink 7 CS (5) 20

injection sites and ChloraPrep preoperative

skin preparation*

SA3716HKI / Safety kit with Point-Lok needle protection 7 CS (5) 16/20

SA3720HKI device, ChloraPrep preoperative skin preparation,

SafetyGlide needles, Futura safety scalpel and

CLC 2000 connector*

Vantex Quad Lumen Catheters – 8.5 French

Model Description Size (F) Unit of Measure Length (cm)

A4816HKIC Expanded kit with heparin, Interlink 8.5 CS (5) 16

injection sites and ChloraPrep preoperative

skin preparation*

A4820HKIC Expanded kit with heparin, Interlink 8.5 CS (5) 20

injection sites and ChloraPrep preoperative

skin preparation*

Vantex Safety Kit PLUS

Model Description Size (F) Unit of Measure Length (cm)

SSA3716HKI/ Safety kit with maximal barrier 7 CS (4) 16/20

SSA3720HKI precautions including full body drape,

cap, mask, gown and insertion checklist*

Page 35: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

3 2

Cen

tralVen

ousAccess

* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated withAMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.

† Decreases viable microbe count on surface of product during handling and placement.

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Non-heparin kits also available.

Multi-Med Central Venous Catheters

These versatile catheters are designed for a variety of uses.

• Multiple uses include fluid administration, blood sampling and pressure monitoring.

• Multi-Med catheter kits contain a guidewire insertion device.

• Available with needleless injection sites - Interlink or CLC 2000 connector.

• Also available with or without AMC Thromboshield* coating, an antimicrobial† heparin coating.

Multi-Med Single Lumen Catheters

Model Description Size (Gauge/F) Unit of Measure Length (cm)

M12013K 20 ga x 5 1/8” (13 cm) expanded kit 3F/20g CS (5) 13

M11620HKIC 16 ga x 8” (20 cm) expanded kit with 5F/16g CS (5) 20

heparin, Interlink injection sites and

ChloraPrep preoperative skin preparation*

M11420HKIC 14 ga x 8” (20 cm) expanded kit with 6F/14g CS (5) 20

heparin, Interlink injection sites and

ChloraPrep preoperative skin preparation*

Multi-Med Double Lumen Catheters – 7 French

Model Description Size (F) Unit of Measure Length (cm)

M2716HKIC Expanded kit with heparin, Interlink 7 CS (5) 16

injection sites and ChloraPrep preoperative

skin preparation*

M2720HKIC Expanded kit with heparin, Interlink 7 CS (5) 20

injection sites and ChloraPrep preoperative

skin preparation*

Proximal Lumen

Distal Lumen

Medial LumenSuture Ring

Suture Wings

Sheath

Page 36: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

3 3

* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated withAMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.

† Decreases viable microbe count on surface of product during handling and placement.

For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.

Cen

tralVen

ousAccess

Multi-Med Double Lumen Catheters – 8.5 French

Model Description Size (F) Unit of Measure Length (cm)

M2816HKIC Expanded kit with heparin, Interlink injection 8.5 CS (5) 16

sites and ChloraPrep preoperative skin preparation*

M2820HKIC Expanded kit with heparin, Interlink injection 8.5 CS (5) 20

sites and ChloraPrep preoperative skin preparation*

Multi-Med Triple Lumen Catheters – 7 French

Model Description Size (F) Unit of Measure Length (cm)

M3716HKIC Expanded kit with heparin, Interlink injection 7 CS (5) 16

sites and ChloraPrep preoperative skin preparation*

SM3716HKI Safety kit with ChloraPrep preoperative skin 7 CS (5) 16

preparation, SafetyGlide needles, Futura safety

scalpel and CLC 2000 connector*

M3720HKIC Expanded kit with heparin, Interlink injection 7 CS (5) 20

and ChloraPrep preoperative skin preparation sites*

SM3720HKI Safety kit with ChloraPrep preoperative skin 7 CS (5) 20

preparation, SafetyGlide needles, Futura safety

scalpel and CLC 2000 connector*

Multi-Med Quad Lumen Catheters

Model Description Size (F) Unit of Measure Length (cm)

M4816HKIC Expanded kit with heparin, Interlink injection 8.5 CS (5) 16

sites and ChloraPrep preoperative skin preparation*

M4820HKIC Expanded kit with heparin, Interlink injection 8.5 CS (5) 20

sites and ChloraPrep preoperative skin preparation*

Page 37: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

3 4

Custo

mer

Servicean

dOrderin

gInform

ation

Customer Service and Ordering Information

Ordering Information

Mailing Address

Edwards LifesciencesOne Edwards WayIrvine, CA 92614

Telephone

General Offices 949-250-2500Customer Service 800-424-3278 (or 949-250-2500)Customer Service (fax) 800-422-9329 (or 949-250-3489)Technical Support 24-Hour Emergency Assistance 800-822-9837 (or 949-250-2222)

Electronic

Edwards Lifesciences is a partner of the Global Healthcare Exchange (GHX). You may also place orders on-line withMy Account, Edwards web ordering system, at www.Edwards.com. For more information about buying our productsusing My Account or GHX, please speak with a Customer Service Representative.

Web Site www.Edwards.com/CriticalCare

In Canada

Edwards Lifesciences, Inc. 800-268-3993

Terms and Conditions

Prices subject to change without prior notice. All applicable taxes will be charged.

Payment

Net 30 days except in Canada where payment terms are in accordance with those stated on the invoice.

Freight

FOB shipping point (prepaid and billed). All merchandise should be inspected on arrival. If merchandise has been damagedin transit, please instruct your receiving department to refuse delivery; then notify Customer Service for further instructions.

Return Goods PolicyEdwards Lifesciences is committed to providing our customers with quality products and service. For this reason,we will happily accept any product for return that:

• is a result of error by Edwards• does not perform to specification

Full credit or replacement will be issued for these products, and no restocking fee will be assessed.

Products returned for other than the above reasons will be subject to a 20% restocking fee.

Authorization is required for all returns. Authorization may be obtained through the Customer Service Department.A Return Goods Authorization number will be issued, and this number must be referenced on all returned packages.

The following merchandise is not acceptable for return:

• sterile items that are returned without the factory seals intact• special order products• incomplete kits or cases• product which has less than 13 months of shelf life

Products that have been used must be packaged as described in “Instructions for Returning Used Products.”

A Technical Support Hotline is available for discussion of all issues regarding disposable products and electronic equipmentrepair. For technical assistance on these issues, please call: 1-800-822-9837 or 949-250-2222.

A Technical Support Specialist will review the problem and issue authorization for the return if the problem cannot beresolved. This authorization is required on all electronic equipment issues. Please be prepared to provide the TechnicalSupport Representative with a purchase order number for the repair.

As part of an ongoing effort to improve the quality of our products, we would like any defective product to be returnedfor evaluation. Credit or replacement will be issued upon Edwards receipt of the defective product.

For educational materials to supplement any of the products in this catalog visit www.Edwards.com/Education or contact your Edwards Lifesciencessales representative.

Page 38: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

3 5

Customer

Servicean

dOrderingInform

ation

Instructions for Returning Used ProductEdwards Lifesciences requests that all products be double-bagged prior to returning them and, if possible, pleasefollow these instructions prior to bagging:

• Prior to handling used product, put on disposable gloves and gown according to hospital procedures.• Visually inspect the product and remove all needles.• Remove all external organic material by carefully wiping the exterior surface with gauze pad or paper towelsaturated with tap water.• Carefully wipe exterior surface of electrical components and connections.• Wipe dry with gauze or paper towel.• Wiping may also be done using one of the following:

-rubbing alcohol-normal saline-Cidex-Omnicide

• Do not use any other cleansing agents other than those listed above; other agents may interfere withevaluation testing.

• CAUTION:Do not flush blood products from lumens or pressure tubing.Do not immerse or submerge product in water.Do not wrap product in tissue paper or apply adhesive tape directly to product; attachments to the product orwriting on the product may interfere with evaluation testing.

• Double-bag using two self-sealing plastic bags. First, place product in one bag and seal. Then place bagged productin second bag and seal.

• Wash hands with soap and water.

• Complete Returned Goods Documentation, describing the reason for return, and staple or paper clip it to top ofplastic bag.

NOTE: Documentation must remain on the outside of the plastic bag to avoid contamination. Attach customeridentification label to outside of plastic bag. Place bagged product into shipping container, place mailing label withEdwards Lifesciences address on the shipping container, and mark the container with the wording “Used Product.”

For Return of Multiple Components or Kits:• Double-bag each complete kit separately.

• Place all individual plastic bags in one large plastic bag, when possible. Then place large bag in shipping container.

Reminder: The purpose of this procedure is only to clean the outer surface area of used product, not to decontaminateit. Should you have any questions regarding these procedures, please call the Edwards Lifesciences Complaints Hotlineat 800-424-3278 or 949-250-3612.

In Canada, please call: 800-268-3993 or: 905-821-9660

Return Address

All ProductsEdwards Lifesciences Corporation1402 E. Alton AvenueIrvine, CA 92606 USA

Attention Return Goods - RGA #______________________

Technical Assistance - 24 Hours

For technical assistance relative to the use, care, and operation of critical-care products,call toll-free 800-822-9837 or 949-250-2222, or via e-mail at [email protected]

For educational materials to supplement any of the products in this catalog visit www.Edwards.com/Education or contact your Edwards Lifesciencessales representative.

Page 39: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

Notes

Page 40: The Continuum of Critical Care - Edwards Lifesciencesht.edwards.com/scin/edwards/sitecollectionimages/products/min... · The Continuum of Critical Care ... For educational materials

Rx only. See instructions for use for full prescribing information.

Edwards, Chandler, CO-Set+, Flex-Tip, IntroFlex, SAT-2, and Vigilance II are trademarks of Edwards Lifesciences Corporation. Edwards Lifesciences, the stylized E logo, AMC Thromboshield,CardioCath, CCOmbo, CCOmbo V, ControlCath, Explorer, FloTrac, Hi-Shore, Multi-Med, Paceport, PediaSat, PreSep, Swan-Ganz, TruCal, TruWave, VAMP, VAMP Jr., VAMP Plus, Vantex,Vigilance, Vigileo, VIP, and VIP+ are trademarks of Edwards Lifesciences Corporation and are registered in the U.S. Patent and Trademark Office.

ChloraPrep is a trademark of Medi-Flex, Inc. CLC 2000 is a registered trademark of ICU Medical, Inc. Early Goal-Directed Therapy is a service mark of Dr. Emanuel Rivers. EGDT is aregistered service mark of Dr. Emanuel Rivers. Futura is a trademark of Futura Medical Group. Interlink is a trademark of Baxter International, Inc., registered in the U.S. Patent andTrademark Office. Oligon is a trademark of Implemed, Inc. Omnicide is a trademark of Southern Mill Creek Products Co., Inc. PhysioTrac is a trademark of Jetcor, Inc. Point-Lok is atrademark of Portex, Inc. SafetyGlide is a trademark of Becton, Dickenson and Company.

© 2009 Edwards Lifesciences LLC. All rights reserved. AR04126

A heritage of developing leading solutionsthat advance the care and treatment of the critically ill

Since the introduction of the Swan-Ganz catheter in the early 1970s,Edwards Lifesciences has partnered with clinicians to develop products and

systems that advance the care and treatment of the critically ill. What hasresulted is an extensive line of hemodynamic monitoring tools including catheters,

sensors and bedside patient monitors that continue to build on thisgold standard in critical care medicine.

Critical care clinicians around the world have used Edwards products to clinicallymanage more than 30 million patients. Hemodynamic monitoring products suchas Swan-Ganz catheters, the FloTrac system and PreSep and PediaSat oximetry

catheters enable clinicians to make more informed and rapid decisions whentreating patients in surgical and critical care settings.

For educational information visit:www.Edwards.com/CriticalCare

Edwards Lifesciences LLC · One Edwards Way · Irvine, CA 92614 USA · 949.250.2500 · 800.424.3278 · www.Edwards.com/CriticalCare