The Canalta Single Chamber Orifice Fitting - 品/1.流量/2-Canalta/... · PDF...

11
An ISO 9001:2008 registered company Phone: 403.342.4494 Email: sales@canaltaflow.com www.canaltaflow.com Exceptional Value means adding to your Bottom Line without sacrificing Quality, Service or Performance The Canalta Single Chamber Orifice Fitting Call Us Toll Free: 1-855-CANALTA

Transcript of The Canalta Single Chamber Orifice Fitting - 品/1.流量/2-Canalta/... · PDF...

Page 1: The Canalta Single Chamber Orifice Fitting - 品/1.流量/2-Canalta/... · PDF filefabricate nearly any combination of weldolets, sockolets, flanged outlets, thre- ... These spec

An ISO 9001:2008 registered company

Phone: 403.342.4494Email: [email protected]

Exceptional Value means adding to your Bottom Linewithout sacrificing Quality, Service or Performance

The Canalta Single Chamber Orifice Fitting

Call Us Toll Free: 1-855-CANALTA

Page 2: The Canalta Single Chamber Orifice Fitting - 品/1.流量/2-Canalta/... · PDF filefabricate nearly any combination of weldolets, sockolets, flanged outlets, thre- ... These spec

2 3

For more information or to order, contact us at Phone: 403.342.4494 | Fax: 403.346.7110 | Email: [email protected] | Web: www.canaltaflow.com An ISO 9001:2008 Registered Company

Single Chamber Orifice Fitting models 8” and larger incorporate a rack and pinion gear system to manage the sizeable weight of large orifice plates and carriers. With this system, plate changing remains quick and easy.

These models also feature fully accessible and adjustable eccentricity of the orifice plate from the exterior of the fitting. Tamper-proof sealing is done on request.

Delivering superiorori�ce �ttings andexceptional value hasbeen our core businessfor over �fteen years.

WCB

LCC

LCC

Canalta Single Chamber Orifice Fitting bodies are available in a number of standard and custom end configurations. Some of our most popular arrangements include

• Flangeneck (welding neck upstream, raised face / RTJ flange downstream)

• Flange X Flange (raised face / RTJ)

• Weldneck both ends

Single Chamber Orifice Fitting Bodies are also available with an extra set of tele-metering tap holes on each side as an option.

Our comprehensive Quality Management System includes full function, hydrostatic and pneumatic pressure testing to prevent defective orifice fittings from reaching service. Standard testing comes at no extra charge and includes verifiable pressurization to 150% of working pressure. Additional inspections, such as radiography, ultra sonic and liquid dye penetration, are also available.

Our unit-specific Documentation packages include hydrostatic, seal and function test results as well as material test reports. An AGA 2000 Inspection Report is submitted with every fitting and includes bore tolerance and roughness tests, orifice eccentricity, seal protrusion, plate sealing tests and other details critical to your process integrity.

Each Canalta Single Chamber Orifice Fitting receives a standard coating that includes a non-lift oxide primer and fast-drying enamel finish in Canalta Grey. Custom coatings for special environments - maritime, humid, high temperature and others - custom colours and primer only applications are also available.

The Canalta Single Chamber Orifice Fitting is a high quality, high accuracy orifice fitting manufactured in a wide selection of sizes and materials. These units are built to meet or exceed ASME and ANSI specifications, as well as to comply with the requirements of the latest editions of AGA-3 / API-14.3 and ISO-5167. Whatever the application, your process will benefit from Canalta’s proven reliability and you can improve your bottom line without sacrificing quality, service or performance.

All Single Chamber Orifice Fittings come standard with HNBR O-ring seals on the seal bar. This feature provides you with superior sealing capability while eliminating nuisance gasket maintenance and clamping bar screw breakage. The O-rings incorporated are standard shelf sizes and can be supplied in a wide variety of compositions. Gaskets are also available and can be used when preferred or required.

Page 3: The Canalta Single Chamber Orifice Fitting - 品/1.流量/2-Canalta/... · PDF filefabricate nearly any combination of weldolets, sockolets, flanged outlets, thre- ... These spec

4 5

For more information or to order, contact us at Phone: 403.342.4494 | Fax: 403.346.7110 | Email: [email protected] | Web: www.canaltaflow.com An ISO 9001:2008 Registered Company

METER RUNS

14

2

3

With literally endless configurations possible, Canalta will custom design and fabricate your meter run for any application.

ACCURACY, RELIABILITY, PERFORMANCE.

3 WELDING SPECIFICATION

TTh

b

tc

__

All Canalta Single Chamber Orifice Fittings can be supplied with complete custom-designed Meter Runs and Flow Conditioning Solutions that meet your exact specification or performance needs.

Threaded

90 ° Elbow

2 END CONNECTION OPTIONS

Welding Neck

Flanged(Raised Face / RTJ)

Canalta Meter Runs can be fabricated with a variety of standard tube ends. All inner surface welds are precision ground and inspected to meet exacting I.D. surface and roundness tolerances. Per your requirements, two and three-piece meter runs can have dissimilar end types up and downstream of the orifice fitting.

4 BRANCH CONNECTION OPTIONSIndustry standard offerings provide one 1” and one 3/4” branch connection on the downstream spool. Our custom meter tube design capability allows us to fabricate nearly any combination of weldolets, sockolets, flanged outlets, thre-adolets and latrolets in any orientation.

0

(Right)

180

90

A - AT.O.L. ORIENTATION

270(Left)

5

5

METER RUN SPECIFICATION PLATEAll Canalta Meter Runs include a specification plate mounted immediately upstream of the orifice fitting. These spec plates detail pipe schedule, pressure rating, maximum beta, maximum orifice and other information essential to proper operation.

Whether the size is 2” or 30”, high or low pressure, wet, dry or corrosive service, we can put together a custom meter run package that meets your specification or performance needs and perfectly matches your Canalta Orifice Fitting.

You trust Canalta at the orifice plate. When accuracy counts, trust Canalta up and downstream, too.

We’ve been working to AGA-3 / API 14.3 and ISO 5167-1 specifications for over fifteen years. Skilled technicians, engineers and inspectors work together to manufacture first-rate meter tubes out of pipe carefully selected and prepared with the appropriate surface requirements, roundness and I.D. tolerances. Hydrostatic test results are included as a standard. PWHT stress relief, ultra-sonic and liquid dye penetration test results are available on request. Our rigorous inspection regime and comprehensive documentation mean you can be sure your meter run is reliable, exceptionally accurate and ready for service.

1 FLOW CONDITIONING ACCESSORIES

Each Canalta Meter Run is professionally fabricated by our team of certified “B” Pressure Welders and experienced pipe finishers to meet and exceed the stringent specifications of AGA /API/ISO. Our welding procedures are registered with the Alberta Boiler and Safety Association (ABSA) and are in accordance with the applicable ASME Boiler and Pressure Vessel Codes. Canalta will ensure that all of your NDT and stress relieving requirements are met with full documentation.

The goal of meter run design is to account for swirl and turbulence. Suitable for a wide range of flow measurement methods and equipment, Canalta’s Contour™ lineup of Flow Conditioners, Flow Conditioner Housings and Straightening Vanes will help you develop the flow profile you need to achieve maximum performance and accuracy in the field.

Page 4: The Canalta Single Chamber Orifice Fitting - 品/1.流量/2-Canalta/... · PDF filefabricate nearly any combination of weldolets, sockolets, flanged outlets, thre- ... These spec

6 7

For more information or to order, contact us at Phone: 403.342.4494 | Fax: 403.346.7110 | Email: [email protected] | Web: www.canaltaflow.com An ISO 9001:2008 Registered Company

ORIFICE PLATE SEAL OPTIONS & CARRIER ASSEMBLIES

Type “K” Standard 2000 Edition Seal AssemblyThis is the standard seal assembly supplied with all orifice fittings from sizes 2” through 8”. This unit is used with a .562” seal gap for fittings sizes 2” through 6”, and with a .688” seal gap for 8” fittings. The single downstream seal function offers superior sealing capability while reducing seal damage during insertion. Plate seal bypass tested down to 1” water column.

Teflon Snap SealThe Teflon Snap Seal provides positive plate sealing in the harshest of process environments. The two-piece design snaps over the orifice plate without the use of metal clips or retainers. A specially designed recess absorbs the insertion pressures, minimizing permanent compression and distortion.

The raised section adjacent to the recess creates a positive seal against the orifice plate, preventing bypass leakage. These two unique design features enhance seal performance while extending the life expectancy of the seal assembly.

TEFLON SNAP RING

TEFLON SNAP RINGORIFICE PLATE

FLOW

BEVEL

HNBR SEAL RING

ORIFICE PLATE STAINLESS STEELRETAINING RING

FLOW

BEVEL

FLOW

BEVEL

Bonded “FLEX” SealThis is the standard seal supplied with all Canalta Orifice Fitting model sizes 10" and larger. Designed with a unique "hollow core" recess, this seal has impressive expansion and contraction capabilities when compared to traditional solid rubber seals. The recess allows the seal to absorb insertion pressures, minimizing tearing, distortion and permanent compression. The 80 duro HNBR seal is adhesively bonded to the orifice plate, creating total and permanent contact between the plate and seal and preventing bypass leakage.

The seal assembly is comprised of an elastomer seal and one stainless steel retainer ring. Exacting and repeatable concentricity is maintained with the metal to metal contact throughout the entire 360° circumference of the orifice plate to the plate carrier mechanism.

Legacy Replacement SealsCanalta supplies a selection of legacy plate seals for situations in which direct and exact seal replacement is required or preferred. Models include two piece clip-style Teflon, solid core HNBR or Nitrile and the stainless steel dual ring assemblies.

We will also work with you to custom design and manufacture purpose-built seals for your unique or special applications.

Page 5: The Canalta Single Chamber Orifice Fitting - 品/1.流量/2-Canalta/... · PDF filefabricate nearly any combination of weldolets, sockolets, flanged outlets, thre- ... These spec

8 9

For more information or to order, contact us at Phone: 403.342.4494 | Fax: 403.346.7110 | Email: [email protected] | Web: www.canaltaflow.com An ISO 9001:2008 Registered Company

Design . . . . . . . . . . . . . . . . . . . . . . .

Body Materials . . . . . . . . . . . . . . .

Internal Parts . . . . . . . . . . . . . . . . .

Sizes and ANSI Class . . . . . . . . . .

U/S D/S Connections . . . . . . . . . .

Internal Bore Sizes . . . . . . . . . . . .

Sealing Compounds . . . . . . . . . .

Line Bore I.D. Tolerance . . . . . . .

Eccentricity Repeatability . . . . .

Tap Connections . . . . . . . . . . . . .

Orifice Plate Seal Gap . . . . . . . . .

Operating Shaft Location . . . . .

Operating Temperature . . . . . . .

Operating Position . . . . . . . . . . .

Orifice fittings supplied in Canada are built in accordance with the ABSA Quality Control Program and carry a CRN registration number.Industry Canada Approval Number AF-0014.In compliance with ASME 16.34 and ASME 16.5, ASTM specifications, AGA-3 Latest Edition and ISO-5167.

A216 WCB, A216 WCC, A352 LCC, A358 CF8M, A995 Gr4A, A995 Gr6A, Custom

AISI 4130 Carbon Steel, 316 or A351 Stainless Steel

2” through 26”, 150 through 1500 ANSI raised face flange600, 900 and 1500 flanges also available in RTJ face flange

Flangeneck design (weldneck U/S, flange D/S)Flange x FlangeWeldneck both ends

40, 60, 80, 100, 120, 160 and custom sizes

Seal bar - HNBR O-ring standard, gasket optionalOrifice plate - Type “K” 2000 Edition formed HNBR seal on a 316 SS retainer ring Dual Ring HNBR O-rings standard on a 316 SS retainer ring assembly Teflon Snap Seal two-piece virgin Teflon assembly

In conformance with AGA-3 and ISO-5167 Latest Editions

In conformance with AGA-3 and ISO-5167 Latest Editions

Two 1/2” NPT per side standard, two 1/2” NPT additional per side optional (TT) 2” and 3” fitting sizes center bored to .375” inside diameter4” and larger sizes center bored to .500” inside diameterTolerance +/- 1/64”

2” through 6” = 0.562”, 8” through 14” = 0.688”, 16” through 20” = 0.813”, 24” through 26” = 0.875”

Shafts are a feature only on fitting sizes 8” and largerLeft hand mount standard on sizes 8” through 16”Dual operation on sizes 20” and larger

Standard at -20° to 100° F, optional -40° to 1200° F

Vertical or horizontal

TECHNICAL SPECIFICATIONS

All fittings come standard with a documentation package including hydro-test, function test, inner valve seal test, quality control inspection and material test reports. Trace ability is maintained in accordance with the ISO-9001 Quality Control Program. The fittings are manufactured within the guidelines of ASME 16.34 and ASME 16.5. When required, radiography, stress relief, ultra-sonic and liquid dye penetration tests can be per-formed with the relevant report submitted.

An AGA 2000 inspection report is included with the purchase of every fitting. The documented tests include: • I.D. Bore Tolerance • Instrument Tap Diameter • Instrument Tap Location • Tap Communication • Plate Seal Test • Seal Protrusion • Orifice Eccentricity • Bore Inside Diameter • Bore Roughness

Conformance

ReportingOur Quality Control systems guarantee that your Canalta Orifice Fittings are service ready, reliable and truly accurate.“

Page 6: The Canalta Single Chamber Orifice Fitting - 品/1.流量/2-Canalta/... · PDF filefabricate nearly any combination of weldolets, sockolets, flanged outlets, thre- ... These spec

10 11

For more information or to order, contact us at Phone: 403.342.4494 | Fax: 403.346.7110 | Email: [email protected] | Web: www.canaltaflow.com An ISO 9001:2008 Registered Company

118K

138H

8G

9A

7

9B

5A

5

6

31

30

12 31 50

4

DIAGRAMS, WEIGHTS & DIMENSIONS - 2” - 6” SINGLE CHAMBER MODELS

YZP CS = Yellow Zinc Plated Carbon SteelA/R = As Required per Model Size

Flangeneck Design (Weldneck Upstream, Flange Downstream)Cast Carbon Steel BodyANSI 150 - 900

Sizes, Dimensions and Weights

For the latest editions of the complete data tables, visit us online at www.canaltaflow.com

Item Qty. Description Material

4 1 Flangeneck Body WCB / LCC / SS

5 2 Plate Carrier Bolt 316 SS

5A 2 Lock Washer 316 SS

6 1 Seal Bar Alignment Pin

7 1 Plate Carrier Alignment Pin

8G 1 Plate Carrier 4130 YZP CS / CF8M SS

8H 1 Seal Ring HNBR

8K 1 “K” Style Retaining Ring 316 SS

9A 1 Seal Bar 1018 YZP CS

9B 1 Seal Bar O-ring HNBR

11 A/R Clamping Bar Screw Case Hardened 4140 CS

12 1 Clamping Bar 1018 YZP CS

13 1 Orifice Plate 304 SS / 316 SS

30 1 Drain Plug A105 CS / 316L SS

31 4 Meter Tap Plug A105 CS / 316L SS

50 1 Specification Plate Color Etched 316 SS

J1

T T

S

K1

O O

1/16”

A

37.5°

R

B C

D

N

M

L K J

1”1”

Avai

labl

e Pi

pe S

ch.

Ups

trea

m F

ace

of O

rific

e Pl

ate

to F

ace

of E

nd

Dow

nstr

eam

Fac

e of

Ori

fice

Plat

e to

Fac

e of

End

Ove

rall

Face

to F

ace

Pipe

O.D

at p

oint

of

Wel

ding

Cent

erlin

e to

Bot

tom

Dia

met

er o

f Fla

nge

Dia

met

er o

f Bol

t Circ

le

Dia

met

er o

f Rai

sed

Face

+0

.000

-0.0

05

Hei

ght o

f Rai

sed

Fac

e

Flan

ge T

hick

ness

Num

ber a

nd D

iam

eter

of

Bolts

or S

tuds

(Per

Fla

nge)

Leng

th o

f Bol

t (St

uds

with

2

Hex

Nut

s)

Cent

er to

face

of 1

/2"

Flan

ge T

aps

Ori

fice

Plat

e Th

ickn

ess

Cent

erlin

e to

Top

Ope

ratin

g Cl

eara

nce

from

Ce

nter

App

roxi

mat

e W

eigh

t (P

ound

s)

SIZE A B C D J1 K1 J K L M N O R S T SIZEANSI 150 - Flangeneck - Standard Raised Face

2 40,80 3.875 3.375 7.375 2.375 3.563 6.000 4.750 3.625 0.063 0.750 4 - 0.625 3.250 3.250 0.125 4.563 5.500 40 2 3 40 4.438 3.688 8.250 3.500 4.063 7.500 6.000 5.000 0.063 0.938 4 - 0.625 3.500 3.700 0.125 5.188 6.000 50 3 4 40 4.938 4.063 9.125 4.500 4.500 9.000 7.500 6.188 0.063 0.938 8 - 0.625 3.500 4.200 0.125 5.625 6.438 65 4 6 40 5.688 5.500 11.313 6.625 5.750 11.000 9.500 8.500 0.063 1.000 8 - 0.625 4.000 5.125 0.125 6.875 7.500 110 6

ANSI 300 - Flangeneck - Standard Raised Face2 40,80 3.875 3.500 7.500 2.375 3.563 6.500 5.000 3.625 0.063 0.875 8 - 0.625 3.500 3.250 0.125 4.563 5.500 40 2 3 40 4.438 3.875 8.438 3.500 4.063 8.250 6.625 5.000 0.063 1.125 8 - 0.750 4.250 3.700 0.125 5.188 6.000 55 3 4 40 4.938 4.313 9.375 4.500 4.500 10.000 7.875 6.188 0.063 1.250 8 - 0.750 4.500 4.200 0.125 5.625 6.438 75 4 6 40,80 5.688 5.500 11.313 6.625 5.750 12.500 10.625 8.500 0.063 1.438 12 - 0.750 4.750 5.125 0.125 6.875 7.500 125 6

ANSI 600 - Flangeneck - Standard Raised Face2 40,80,160 3.813 3.875 7.813 2.375 3.563 6.500 5.000 3.625 0.250 1.250 8 - 0.750 4.250 3.250 0.125 4.563 5.500 45 2 3 40,80 4.438 4.188 8.750 3.500 4.063 8.250 6.625 5.000 0.250 1.500 8 - 0.750 5.000 3.700 0.125 5.188 6.000 70 3 4 40,80 4.938 4.750 9.813 4.500 4.500 10.750 8.500 6.188 0.250 1.750 8 - 0.875 5.750 4.200 0.125 5.625 6.438 100 4 6 40,80 5.688 5.688 11.500 6.625 5.750 14.000 11.500 8.500 0.250 2.125 12 - 1.000 6.750 5.125 0.125 6.875 7.500 155 6

ANSI 600 - Flangeneck - Ring Type Joint2 40,80,160 3.875 3.875 7.875 2.375 3.563 6.500 5.000 3.625 0.313 1.313 8 - 0.625 4.250 3.250 0.125 4.563 5.500 45 2 3 40,80 4.438 4.250 8.813 3.500 4.063 8.250 6.625 5.000 0.313 1.563 8 - 0.750 5.000 3.700 0.125 5.188 6.000 70 3 4 40,80 4.938 4.813 9.875 4.500 4.500 10.750 8.500 6.188 0.313 1.813 8 - 0.875 5.750 4.200 0.125 5.625 6.438 100 4 6 40,80 5.688 5.750 11.563 6.625 5.750 14.000 11.500 8.500 0.313 2.188 12 - 1.000 6.750 5.125 0.125 6.875 7.500 155 6

ANSI 900 - Flangeneck - Standard Raised Face2 40,80,160 3.938 4.563 8.625 2.375 3.563 8.500 6.500 3.625 0.250 1.750 8 - 0.875 5.750 3.250 0.125 4.563 5.500 70 2 3 40,80,160 4.438 4.438 9.000 3.500 4.063 9.500 7.500 5.000 0.250 1.750 8 - 0.875 5.750 3.700 0.125 5.188 6.000 80 3 4 80,160 4.938 5.000 10.063 4.500 4.500 11.500 9.250 6.188 0.250 2.000 8 - 1.125 6.750 4.200 0.125 5.625 6.438 125 4 6 80,160 5.688 5.688 11.500 6.625 5.750 15.000 12.500 8.500 0.250 2.438 12 - 1.125 7.750 5.125 0.125 6.875 7.500 269 6

ANSI 900 - Flangeneck - Ring Type Joint2 40,80,160 3.938 4.625 8.688 2.375 3.563 8.500 6.500 3.625 0.313 1.813 8 - 0.875 5.750 3.250 0.125 4.563 5.500 70 2 3 40,80,160 4.438 4.500 9.063 3.500 4.063 9.500 7.500 5.000 0.313 1.813 8 - 0.875 5.750 3.700 0.125 5.188 6.000 80 3 4 80,160 4.938 5.063 10.125 4.500 4.500 11.500 9.250 6.188 0.313 2.063 8 - 1.125 6.750 4.200 0.125 5.625 6.438 125 4 6 80,160 5.688 5.750 11.563 6.625 5.750 15.000 12.500 8.500 0.313 2.500 12 - 1.125 7.750 5.125 0.125 6.875 7.500 269 6

Data REV 08 - 11/2012

Page 7: The Canalta Single Chamber Orifice Fitting - 品/1.流量/2-Canalta/... · PDF filefabricate nearly any combination of weldolets, sockolets, flanged outlets, thre- ... These spec

12 13

For more information or to order, contact us at Phone: 403.342.4494 | Fax: 403.346.7110 | Email: [email protected] | Web: www.canaltaflow.com An ISO 9001:2008 Registered Company

DIAGRAMS, WEIGHTS & DIMENSIONS - 2” - 6” SINGLE CHAMBER MODELS

Flange x Flange (Raised Face / Ring Type Joint)Cast Carbon Steel BodyANSI 150 - 900

Weldneck Both EndsCast Carbon Steel BodyANSI 150 - 900

K1

S

T T

O O

A

B CD

N

M

JKL

Sizes, Dimensions and Weights Sizes, Dimensions and Weights

J1 A

R

B C

D

T T

S

K1

O O

For the latest editions of the complete data tables, visit us online at www.canaltaflow.com

Avai

labl

e Pi

pe S

ch.

Ups

trea

m F

ace

of O

rific

e Pl

ate

to F

ace

of E

nd

Dow

nstr

eam

Fac

e of

Ori

fice

Plat

e to

Fac

e of

End

Ove

rall

Face

to F

ace

Cent

erlin

e to

Bot

tom

Dia

met

er o

f Fla

nge

Dia

met

er o

f Bol

t Circ

le

Dia

met

er o

f Rai

sed

Face

+0

.000

-0.0

05

Hei

ght o

f Rai

sed

Fac

e

Flan

ge T

hick

ness

Num

ber a

nd D

iam

eter

of

Bolts

or S

tuds

(Per

Fla

nge)

Leng

th o

f Bol

t (St

uds

with

2

Hex

Nut

s)

Cent

er to

face

of 1

/2"

Flan

ge T

aps

Ori

fice

Plat

e Th

ickn

ess

Cent

erlin

e to

Top

Ope

ratin

g Cl

eara

nce

from

Ce

nter

App

roxi

mat

e W

eigh

t (P

ound

s)

SIZE A B C D K1 J K L M N O S T SIZEANSI 150 - Flange x Flange - Standard Raised Face

2 40,80 3.938 3.313 7.375 3.563 6.000 4.750 3.625 0.063 0.750 4 - 0.625 3.250 3.250 0.125 4.563 5.500 45 2 3 40 4.438 3.688 8.250 4.063 7.500 6.000 5.000 0.063 0.938 4 - 0.625 3.750 3.700 0.125 5.188 6.000 59 3 4 40 4.938 4.063 9.063 4.500 9.000 7.500 6.188 0.063 0.938 8 - 0.625 3.750 4.200 0.125 5.625 6.438 77 4 6 40 5.688 5.500 11.313 5.750 11.000 9.500 8.500 0.063 1.000 8 - 0.625 4.000 5.125 0.125 6.875 7.500 128 6

ANSI 300 - Flange x Flange - Standard Raised Face2 40,80 3.938 3.438 7.500 3.563 6.500 5.000 3.625 0.063 0.875 8 - 0.625 3.500 3.250 0.125 4.563 5.500 47 2 3 40 4.438 3.875 8.438 4.063 8.250 6.625 5.000 0.063 1.125 8 - 0.750 4.250 3.700 0.125 5.188 6.000 68 3 4 40 4.938 4.313 9.375 4.500 10.000 7.875 6.188 0.063 1.250 8 - 0.750 4.500 4.200 0.125 5.625 6.438 96 4 6 40,80 5.688 5.500 11.313 5.750 12.500 10.625 8.500 0.063 1.438 12 - 0.750 5.000 5.125 0.125 6.875 7.500 160 6

ANSI 600 - Flange x Flange - Standard Raised Face2 40,80,160 3.875 3.875 7.875 3.563 6.500 5.000 3.625 0.250 1.250 8 - 0.625 4.500 3.250 0.125 4.563 5.500 53 2 3 40,80 4.438 4.188 8.750 4.063 8.250 6.625 5.000 0.250 1.500 8 - 0.750 5.000 3.700 0.125 5.188 6.000 85 3 4 40,80 4.938 4.750 9.813 4.500 10.750 8.500 6.188 0.250 1.750 8 - 0.875 5.750 4.200 0.125 5.625 6.438 133 4 6 40,80 5.688 5.688 11.500 5.750 14.000 11.500 8.500 0.250 2.125 12 - 1.000 6.750 5.125 0.125 6.875 7.500 235 6

ANSI 600 - Flange x Flange - Ring Type Joint2 40,80,160 3.938 3.813 7.875 3.563 6.500 5.000 3.625 0.313 1.250 8 - 0.625 4.500 3.250 0.125 4.563 5.500 53 2 3 40,80 4.438 4.188 8.750 4.063 8.250 6.625 5.000 0.313 1.500 8 - 0.750 5.000 3.700 0.125 5.188 6.000 85 3 4 40,80 4.938 4.813 9.875 4.500 10.750 8.500 6.188 0.313 1.750 8 - 0.875 5.750 4.200 0.125 5.625 6.438 133 4 6 40,80 5.688 5.750 11.563 5.750 14.000 11.500 8.500 0.313 2.125 12 - 1.000 6.750 5.125 0.125 6.875 7.500 235 6

ANSI 900 - Flange x Flange - Standard Raised Face2 40,80,160 3.938 4.250 8.313 3.563 8.500 6.500 3.625 0.250 1.750 8 - 0.875 5.750 3.250 0.125 4.563 5.500 95 2 3 40,80,160 4.438 4.438 9.000 4.063 9.500 7.500 5.000 0.250 1.750 8 - 0.875 5.750 3.700 0.125 5.188 6.000 111 3 4 80,160 4.938 5.000 10.063 4.500 11.500 9.250 6.188 0.250 2.000 8 - 1.125 6.750 4.200 0.125 5.625 6.438 178 4 6 80,160 5.688 5.688 11.500 5.750 15.000 12.500 8.500 0.250 2.438 12 - 1.125 7.750 5.125 0.125 6.875 7.500 377 6

ANSI 900 - Flange x Flange - Ring Type Joint2 40,80,160 3.938 4.563 8.625 3.563 8.500 6.500 3.625 0.313 1.750 8 - 0.875 5.750 3.250 0.125 4.563 5.500 95 2 3 40,80,160 4.438 4.500 9.063 4.063 9.500 7.500 5.000 0.313 1.750 8 - 0.875 5.750 3.700 0.125 5.188 6.000 111 3 4 80,160 4.938 5.063 10.125 4.500 11.500 9.250 6.188 0.313 2.000 8 - 1.125 6.750 4.200 0.125 5.625 6.438 178 4 6 80,160 5.688 5.750 11.563 5.750 15.000 12.500 8.500 0.313 2.438 12 - 1.125 7.750 5.125 0.125 6.875 7.500 377 6

Avai

labl

e Pi

pe

Sch.

Ups

trea

m F

ace

of O

rifice

Pla

te to

Be

vel

Dow

nstr

eam

Fac

e of

Orifi

ce P

late

to

Beve

l

Ove

rall

End

to

End

Pipe

O.D

at p

oint

of

Wel

ding

Cent

erlin

e to

Bo

ttom

Cent

er to

face

of

1/2"

Fla

nge

Taps

Orifi

ce P

late

Th

ickn

ess

Cent

erlin

e to

Top

Ope

ratin

g Cl

eara

nce

from

Ce

nter

App

roxi

mat

e W

eigh

t (Po

unds

)

SIZE A B C D J1 K1 O R S T SIZE

Weldneck Configuration

2 40,80,160 3.812 3.875 7.812 2.375 3.563 3.250 0.125 4.563 5.500 50 2

3 40,80,160 4.437 4.188 8.750 3.500 4.063 3.700 0.125 5.188 6.000 60 3

4 80,160 4.938 4.751 9.813 4.500 4.500 4.200 0.125 5.625 6.438 80 4

6 80,160 5.688 5.688 11.375 6.625 5.750 5.125 0.125 6.875 7.500 125 6

Data REV 08 - 11/2012

Data REV 08 - 11/2012

Page 8: The Canalta Single Chamber Orifice Fitting - 品/1.流量/2-Canalta/... · PDF filefabricate nearly any combination of weldolets, sockolets, flanged outlets, thre- ... These spec

14 15

For more information or to order, contact us at Phone: 403.342.4494 | Fax: 403.346.7110 | Email: [email protected] | Web: www.canaltaflow.com An ISO 9001:2008 Registered Company

DIAGRAMS, WEIGHTS & DIMENSIONS - 8” - 16” SINGLE CHAMBER MODELS

Item Qty. Description Material

2 1 Operating Wrench Coated Cast Iron

4 1 Flangnek Body WCB / LCC / SS

5 1 Shaft and Pinions 4130 YZP CS / CF8M SS

8 1 Plate Carrier 4130 YZP CS / CF8M SS

8H 1 Seal Ring HNBR

8K 1 “K” Style Retaining Ring 316 SS

9B 1 Seal Bar O-ring HNBR

9G 1 Seal Bar 1018 YZP CS

11 A/R Clamping Bar Screws Case Hardened 4140 CS

12 1 Clamping Bar 1018 YZP CS

13 1 Orifice Plate 304 SS / 316 SS

19 1 Bearing Plug 4130 YZP CS

20 1 Stuffing Box 4130 YZP CS

Item Qty. Description Material

22A 2 Stuffing Box Gasket 316 SS

25 1 Packing Nut 4130 YZP CS

25A-F A/R Packing Sleeves Teflon

25S 1 Complete Packing Set Teflon

26 1 Stuffing Box Gland 316 SS

26A 1 Stuffing Box Inner Gland Seal HNBR

26B 1 Stuffing Box Outer Gland Seal HNBR

28A-E 2 Bushing Retainer 316 SS

30 2 Drain Plug A105 CS / 316L SS

31 4 Meter Tap Plug A105 CS / 316L SS

50 1 Specification Plate Color Etched 316 SS

55 3 Eccentricity Alignment Pins 18/8 SS

56 3 Eccentricity Alignment Pin Plugs

58 1 Plate Carrier Alignment Screw 18/8 SS

9G

9B

58

8

8H

13

8K

11

12

19

22A

25A

28E

56

31

55

30

55

56

30

31

56

55

25

2526A

2626B

25E25C

2022A

25A28A4

50

Flangeneck Design (Weldneck Upstream, Flange Downstream)Cast Carbon Steel BodyANSI 150 - 900

Sizes, Dimensions and Weights

T

1”

K1

O

S

C

D

B

J K L A

MN

R

J1

For the latest editions of the complete data tables, visit us online at www.canaltaflow.com

YZP CS = Yellow Zinc Plated Carbon SteelA/R = As Required per Model Size

Avai

labl

e Pi

pe S

ch.

Ups

trea

m F

ace

of O

rific

e Pl

ate

to F

ace

of E

nd

Dow

nstr

eam

Fac

e of

Ori

fice

Plat

e to

Fac

e of

End

Ove

rall

Face

to F

ace

Pipe

O.D

at p

oint

of

Wel

ding

Cent

erlin

e to

Bot

tom

Dia

met

er o

f Fla

nge

Dia

met

er o

f Bol

t Circ

le

Dia

met

er o

f Rai

sed

Face

+0.0

00 -0

.005

Hei

ght o

f Rai

sed

Face

Flan

ge T

hick

ness

Num

ber a

nd D

iam

eter

of

Bolts

or S

tuds

(Per

Fla

nge)

Leng

th o

f Bol

t (S

tuds

with

2 H

ex N

uts)

Cent

er to

face

of 1

/2"

Flan

ge T

aps

Ori

fice

Plat

e Th

ickn

ess

Cent

erlin

e to

Top

Ope

ratin

g Cl

eara

nce

from

Ce

nter

App

roxi

mat

e W

eigh

t (P

ound

s)

SIZE A B C D J1 K1 J K L M N O R S T SIZEANSI 150 - Flangeneck - Standard Raised Face

8 40 7.250 7.250 14.750 8.625 8.250 13.500 11.750 10.625 0.063 1.062 8 - 0.750 4.250 7.000 0.250 8.750 16.000 375 810 40 8.313 8.750 17.313 10.750 10.062 16.000 14.250 12.750 0.063 1.125 12 - 0.875 4.750 7.875 0.250 10.500 17.375 640 1012 STD,40,80 9.875 9.875 20.000 12.750 11.750 19.000 17.000 15.000 0.063 1.188 12 - 0.875 4.750 9.500 0.250 11.313 16.875 875 1216 30, 40 10.813 11.313 22.500 16.000 13.875 23.500 21.250 18.500 0.063 1.313 16 - 1.000 5.500 12.375 0.375 13.750 23.250 1135 16

ANSI 300 - Flangeneck - Standard Raised Face8 40,80 7.250 7.250 14.750 8.625 8.250 15.000 13.000 10.625 0.063 1.625 12 - 0.875 5.500 7.000 0.250 8.750 16.000 400 8

10 40, 60, 80 8.313 8.750 17.313 10.750 10.062 17.500 15.250 12.750 0.063 1.875 16 - 1.000 6.250 7.875 0.250 10.500 17.375 680 1012 STD,40,80 9.875 9.875 20.000 12.750 11.750 20.500 17.750 15.000 0.063 1.938 16 - 1.125 6.750 9.500 0.250 11.313 16.875 925 1216 30, 40 10.813 11.313 22.500 16.000 13.875 25.500 22.500 18.500 0.063 2.188 20 - 1.250 7.500 12.375 0.375 13.750 23.250 1260 16

ANSI 600 - Flangeneck - Standard Raised Face8 80 7.250 7.250 14.750 8.625 8.250 16.500 13.750 10.625 0.250 2.188 12 - 1.125 7.250 7.000 0.250 8.750 16.000 520 8

10 60,80 8.313 8.750 17.313 10.750 10.063 20.000 17.000 12.750 0.250 2.500 16 - 1.250 8.250 7.875 0.250 10.500 17.375 685 1012 80 9.875 9.875 20.000 12.750 11.750 22.000 19.250 15.000 0.250 2.625 20 - 1.250 8.500 9.500 0.250 11.313 16.875 880 1216 60,80 10.813 11.313 22.500 16.000 13.875 27.000 23.750 18.500 0.250 3.000 20 - 1.500 9.750 12.375 0.375 13.750 23.250 1560 16

ANSI 600 - Flangeneck - Ring Type Joint8 80 7.250 7.250 14.750 8.625 8.250 16.500 13.750 11.875 0.312 2.188 12 - 1.125 7.750 7.000 0.250 8.750 16.000 520 8

10 60,80 8.313 8.750 17.313 10.750 10.063 20.000 17.000 14.000 0.312 2.500 16 - 1.250 8.500 7.875 0.250 10.500 17.375 685 1012 80 9.875 9.875 20.000 12.750 11.750 22.000 19.250 16.250 0.313 2.625 20 - 1.250 8.750 9.500 0.250 11.313 16.875 880 1216 60,80 10.813 11.313 22.500 16.000 13.875 27.000 23.750 20.000 0.313 3.000 20 - 1.500 10.000 12.375 0.375 13.750 23.250 1560 16

ANSI 900 - Flangeneck - Standard Raised Face8 100, 120 7.250 7.250 14.750 8.625 8.250 18.500 15.500 10.625 0.250 2.500 12 - 1.375 8.500 7.000 0.250 8.750 16.000 520 8

10 100, 120 8.313 8.750 17.313 10.750 10.063 21.500 18.500 12.750 0.250 2.750 16 - 1.375 9.000 7.875 0.250 10.500 17.375 1100 1012 100, 120 9.875 9.875 20.000 12.750 11.750 24.000 21.000 15.000 0.250 3.125 20 - 1.375 9.750 9.500 0.250 11.313 16.875 1150 1216 100, 120 10.813 11.313 22.500 16.000 13.875 27.750 24.250 18.500 0.250 3.500 20 - 1.625 11.000 12.375 0.375 13.750 23.250 1670 16

ANSI 900 - Flangeneck - Ring Type Joint8 100, 120 7.250 7.250 14.750 8.625 8.250 18.500 15.500 12.125 0.312 2.500 12 - 1.375 8.750 7.000 0.250 8.750 16.000 520 8

10 100, 120 8.313 8.750 17.313 10.750 10.063 21.500 18.500 14.250 0.312 2.750 16 - 1.375 9.250 7.875 0.250 10.500 17.375 1100 1012 100, 120 9.875 9.875 20.000 12.750 11.750 24.000 21.000 16.500 0.312 3.125 20 - 1.375 10.000 9.500 0.250 11.313 16.875 1150 1216 100, 120 10.813 11.313 22.500 16.000 13.875 27.750 24.250 20.625 0.438 3.500 20 - 1.625 11.500 12.375 0.375 13.750 23.250 1670 16

Data REV 08 - 11/2012

Page 9: The Canalta Single Chamber Orifice Fitting - 品/1.流量/2-Canalta/... · PDF filefabricate nearly any combination of weldolets, sockolets, flanged outlets, thre- ... These spec

16 17

For more information or to order, contact us at Phone: 403.342.4494 | Fax: 403.346.7110 | Email: [email protected] | Web: www.canaltaflow.com An ISO 9001:2008 Registered Company

DIAGRAMS, WEIGHTS & DIMENSIONS - 8” - 16” SINGLE CHAMBER MODELS

Flange x FlangeCast Carbon Steel BodyANSI 150 - 900

Sizes, Dimensions and Weights

For the latest editions of the complete data tables, visit us online at www.canaltaflow.com

INSTALLATION RECOMMENDATIONSThe Single Chamber Orifice Fitting is typically installed in conjunction with upstream and downstream me-ter run sections (tubes). This is essential to meet the recommendations of both AGA Report 3 and ISO 5167. To obtain the best measurement results, follow the recommended piping configurations and installation requirements of either of these two standards, as well as the recommendations below.

1. Always ensure that operating staff are competent and properly trained to operate this and all other pressurized equipment.

2. When installing the fitting or meter run, ensure that the flow arrow on the outer surface of the fitting corresponds to the direction of flow in the line.

3. Attention to clearances is essential. Consult the attached dimensional drawings and tables for details. Ensure there is operating clearance above the top of the fitting for removal of the plate carrier. For 8” - 16” Single Chamber models, additional clearance at the sides of the fitting is necessary for pinion gear rotation and operating wrench removal.

4. When used to measure wet gas, the vertical mount is recommended to prevent dam formation against the orifice plate.

5. Instrument tap lines should be installed sloping upwards to the differential pressure measurement instrument. Where this cannot be accomplished, use seal pots to chemically seal the sensing lines and eliminate hydrostatic head errors.

6. To avoid damage to the orifice plate, ensure that the orifice plate and plate carrier are removed from the fitting prior to pressure testing the system.

7. Before inserting the orifice plate and plate carrier into the fitting, always ensure that the lower cavity of the fitting is free of debris. If debris has accumulated, remove the lower drain plugs and rod-clean the lower section.

T

1”

O

K1

S

N

M

J K L A

B

DC

R

Avai

labl

e Pi

pe S

ch.

Ups

trea

m F

ace

of O

rific

e Pl

ate

to F

ace

of E

nd

Dow

nstr

eam

Fac

e of

Ori

fice

Plat

e to

Fac

e of

End

Ove

rall

Face

to F

ace

Cent

erlin

e to

Bot

tom

Dia

met

er o

f Fla

nge

Dia

met

er o

f Bol

t Circ

le

Dia

met

er o

f Rai

sed

Face

+0

.000

-0.0

05

Hei

ght o

f Rai

sed

Face

Flan

ge T

hick

ness

Num

ber a

nd D

iam

eter

of

Bolts

or S

tuds

(Per

Fla

nge)

Leng

th o

f Bol

t (St

uds

with

2

Hex

Nut

s)

Cent

er to

face

of 1

/2"

Flan

ge T

aps

Ori

fice

Plat

e Th

ickn

ess

Cent

erlin

e to

Top

Ope

ratin

g Cl

eara

nce

from

Ce

nter

App

roxi

mat

e W

eigh

t (P

ound

s)

SIZE A B C D K1 J K L M N O R S T SIZEANSI 150 - Flange x Flange - Standard Raised Face

8 40 7.250 7.250 14.750 8.250 13.500 11.750 10.625 0.063 1.062 8 - 0.750 4.250 7.000 0.250 8.750 16.000 400 8 10 40 8.313 8.750 17.313 10.062 16.000 14.250 12.750 0.063 1.125 12 - 0.875 4.750 7.875 0.250 10.500 17.375 675 10 12 STD,40,80 9.875 9.875 20.000 11.750 19.000 17.000 15.000 0.063 1.188 12 - 0.875 4.750 9.500 0.250 11.313 16.875 935 12 16 30, 40 10.813 11.313 22.500 13.875 23.500 21.250 18.500 0.063 1.313 16 - 1.000 5.500 12.375 0.375 13.750 23.250 1225 16

ANSI 300 - Flange x Flange - Standard Raised Face8 40,80 7.250 7.250 14.750 8.250 15.000 13.000 10.625 0.063 1.625 12 - 0.875 5.500 7.000 0.250 8.750 16.000 450 8

10 40, 60, 80 8.313 8.750 17.313 10.062 17.500 15.250 12.750 0.063 1.875 16 - 1.000 6.250 7.875 0.250 10.500 17.375 755 10 12 STD,40,80 9.875 9.875 20.000 11.750 20.500 17.750 15.000 0.063 1.938 16 - 1.125 6.750 9.500 0.250 11.313 16.875 1035 12 16 30, 40 10.813 11.313 22.500 13.875 25.500 22.500 18.500 0.063 2.188 20 - 1.250 7.500 12.375 0.375 13.750 23.250 1480 16

ANSI 600 - Flange x Flange - Standard Raised Face8 80 7.250 7.250 14.750 8.250 16.500 13.750 10.625 0.250 2.188 12 - 1.125 7.250 7.000 0.250 8.750 16.000 540 8

10 60,80 8.313 8.750 17.313 10.063 20.000 17.000 12.750 0.250 2.500 16 - 1.125 8.250 7.875 0.250 10.500 17.375 960 10 12 80 9.875 9.875 20.000 11.750 22.000 19.250 15.000 0.250 2.625 20 - 1.250 8.500 9.500 0.250 11.313 16.875 1250 12 16 60,80 10.813 11.313 22.500 13.875 27.000 23.750 18.500 0.250 3.000 20 - 1.500 9.750 12.375 0.375 13.750 23.250 1875 16

ANSI 600 - Flange x Flange - Ring Type Joint8 80 7.250 7.250 14.750 8.250 16.500 13.750 11.875 0.312 2.188 12 - 1.125 7.750 7.000 0.250 8.750 16.000 540 8

10 60,80 8.313 8.750 17.313 10.063 20.000 17.000 14.000 0.312 2.500 16 - 1.250 8.500 7.875 0.250 10.500 17.375 960 10 12 80 9.875 9.875 20.000 11.750 22.000 19.250 16.250 0.313 2.625 20 - 1.250 8.750 9.500 0.250 11.313 16.875 1250 12 16 60,80 10.813 11.313 22.500 13.875 27.000 23.750 20.000 0.313 3.000 20 - 1.500 10.000 12.375 0.375 13.750 23.250 1875 16

ANSI 900 - Flange x Flange - Standard Raised Face8 100, 120 7.250 7.250 14.750 8.250 18.500 15.500 10.625 0.250 2.500 12 - 1.375 8.500 7.000 0.250 8.750 16.000 690 8

10 100, 120 8.313 8.750 17.313 10.063 21.500 18.500 12.750 0.250 2.750 16 - 1.375 9.000 7.875 0.250 10.500 17.375 1100 10 12 100, 120 9.875 9.875 20.000 11.750 24.000 21.000 15.000 0.250 3.125 20 - 1.375 9.750 9.500 0.250 11.313 16.875 1475 12 16 100, 120 10.813 11.313 22.500 13.875 27.750 24.250 18.500 0.250 3.500 20 - 1.625 11.000 12.375 0.375 13.750 23.250 2125 16

ANSI 900 - Flange x Flange - Ring Type Joint8 100, 120 7.250 7.250 14.750 8.250 18.500 15.500 12.125 0.312 2.500 12 - 1.375 8.750 7.000 0.250 8.750 16.000 690 8

10 100, 120 8.313 8.750 17.313 10.063 21.500 18.500 14.250 0.312 2.750 16 - 1.375 9.250 7.875 0.250 10.500 17.375 1100 10 12 100, 120 9.875 9.875 20.000 11.750 24.000 21.000 16.500 0.312 3.125 20 - 1.375 10.000 9.500 0.250 11.313 16.875 1475 12 16 100, 120 10.813 11.313 22.500 13.875 27.750 24.250 20.625 0.438 3.500 20 - 1.625 11.500 12.375 0.375 13.750 23.250 2125 16

Data REV 08 - 11/2012

Page 10: The Canalta Single Chamber Orifice Fitting - 品/1.流量/2-Canalta/... · PDF filefabricate nearly any combination of weldolets, sockolets, flanged outlets, thre- ... These spec

18 19

For more information or to order, contact us at Phone: 403.342.4494 | Fax: 403.346.7110 | Email: [email protected] | Web: www.canaltaflow.com An ISO 9001:2008 Registered Company

118K

13

8H

8

9G

12

5

3031

OPERATING INSTRUCTIONS - 8” - 16” SINGLE CHAMBER MODELS

To remove the orifice plate(a) Ensure that the fitting is completely depressurized.(b) Loosen the clamping bar screws (11).(c) Remove the clamping bar (12) and seal bar (9G).(d) Rotate the plate carrier pinion gear (5) to raise the plate carrier assembly.(e) Remove the orifice plate (13) and seal assembly (8H, 8K) from the plate carrier (8).(f ) Extract the orifice plate (13) from the seal.

To replace the orifice plate(A) Reinstall the orifice plate (13) into the seal.(B) Install the seal assembly (8H, 8K) into the plate carrier (8), ensuring that the orifice plate bevel faces downstream.(C) Insert the plate carrier assembly into the fitting and lower it using the plate carrier pinion gear (5).(D) Replace the seal bar (9G) and clamping bar (12).(E) Tighten the clamping bar screws (11).(F) Check that the meter tap and drain plugs (30, 31) are properly tightened.(G) Repressurize and return the line to service.

OPERATING INSTRUCTIONS - 2” - 6” SINGLE CHAMBER MODELS

11

13

9B

12

30

31

8

51

To remove the orifice plate(a) Ensure that the fitting is completely depressurized.(b) Loosen the clamping bar screws (11) and remove the clamping bar (12).(c) Remove the plate carrier and seal bar unit (8).(d) Remove the orifice plate and seal assembly (13) from the plate carrier.(e) Extract the orifice plate from the seal.

To replace the orifice plate(A) Reinstall the orifice plate into the seal.(B) Install the seal assembly (13) into the plate carrier (8), ensuring that the orifice plate bevel faces down stream.(C) Check that the seal bar O-ring or gasket is clean and in position.(D) Replace the plate carrier and seal bar unit (8) while ensuring that the index hole (9B) is placed over the seal bar alignment pin (51).(E) Slide the clamping bar (12) back into place and tighten the clamping bar screws (11). (F) Check that the meter tap and drain plugs (30, 31) are properly tightened.(G) Repressurize and return the line to service.

WARNING: The unit may be under extreme high pressure. Failure to depressurize the line before attempting to remove the seal bar may result in bodily harm or death. Follow all instructions carefully.

These instructions are attached to the body of each Canalta Single Chamber Orifice Fitting. Ensure that all operating staff are fully trained in the safe operation of this and all other pressurized equipment.

WARNING: PRESSURIZED UNIT.Ensure all operating staff are trained in the safe operation of this an all other pressurized equipment.

WARNING: PRESSURIZED UNIT.Ensure all operating staff are trained in the safe operation of this an all other pressurized equipment.

Page 11: The Canalta Single Chamber Orifice Fitting - 品/1.流量/2-Canalta/... · PDF filefabricate nearly any combination of weldolets, sockolets, flanged outlets, thre- ... These spec

Canalta also offers these other high quality product lines. Visit us on the web at www.canaltaflow.com to get all the information, or contact us to request print materials.

The Canalta Dual Chamber Orifice FittingA high quality, high accuracy orifice fitting manufactured in a wide selection of sizes and materials, the Canalta Dual Chamber Orifice Fitting is designed and constructed to allow for orifice plate inspection or replacement under pressure without interrup-tion in the flow line.

Available as fitting only or with complete meter run, 150# - 2500# ANSI ratings, with carbon or stainless steel internals and a variety of connection configurations.

Parts, Accessories & Repair KitsParts and repair kits available for Single and Dual Chamber Orifice Fittings, meter runs and flow conditioning solutions.

ADDITIONAL PRODUCT LINES

Our parts and accessories offerings are interchangeable with the current industry standard orifice fitting brand, making Canalta Orifice Fitting internals suitable for re-builds and re-works of our competitors’ product lines at substantial cost savings.

CONTACT INFORMATION

Phone: 403.342.4494Fax: 403.346.7110

Email: [email protected] Web: www.canaltaflow.com

6759 65th AvenueRed Deer, AB T4P 1X5

CANADAFind a list of our global distribution partners at www.canaltaflow.com/global

The "Canalta Flow Measurement" name and logo are trademarks of Canalta Controls Ltd. All other trademarks are the property of their respective companies.

All information presented here is for information purposes only. Though every effort has been made to ensure their accuracy, the contents of this publication shall not be construed as warranties or guarantees, expressed or implied, regarding the products or services described herein, or their use or applicability. Due to Canalta’s commitment to quality and innovation, all product designs, specifications and information material, including the contents of this publication, are subject to change without notice. Responsibility for the proper selection, maintenance and use of any product remains with the customer. SAFETY FIRST.

Copyright, trademark and other forms of proprietary rights protect the contents of this publication.

© 2011 Canalta Controls Ltd. All rights reserved. Unauthorized reproduction in whole or in part is prohibited.

Call Us Toll Free: 1-855-CANALTA