The better way to buildTM
Design Handbook
EXTERIOR WALLS
FROST WALLS FOUNDATION WALLS
FLOORS
ROOFS & CEILINGS
Design Handbook General Notes1. Calculated R-Values listed above are for a generic SIP, including 2 sheets of 7/16” OSB.
References: ASHRAE Handbook - 1981 Edition: Table 1 - Conductivity & Resistance EPS Products (at -50F); Structural Board Association OSB Performance by Design 2002: Table 4 Physical Properties of OSB
2. SIP structural members designed according to 2010 NBC Division B, Section 4.1.
3. Contact Thermapan Structural Insulated Panels, Inc. for panel sizes not listed.
2
SIP Thickness: inch (mm)
4.5” (114)
6.5” (165)
8.25” (210)
10.25” (260)
12.25” (311)
EPS Core Thickness: inch (mm)
3-5/8” (92)
5-5/8” (143)
7-3/8” (187)
9-3/8” (238)
11-3/8” (289)
Dimensional Lumber: nominal inches (actual mm)
2x4(38x89)
2x6 (38x140)
2x8 (38x184)
2x10 (38x235)
2x12 (38x286)
Weight: lbs./sq.ft. (kg/m2)
3.13 (15.3)
3.32 (16.2)
3.48 (17.0)
3.66 (17.9)
3.84 (18.7)
R-Value (RSI)
19 (3.34)
29 (5.10)
38 (6.67)
48 (8.44)
58 (10.2)
Dimensions & Specifications (Standard SIP)
Technical Data
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . 2
Exterior Wall SIP . . . . . . . . . . . . . . . . . . . . . . 3
Panel Header / Lintel . . . . . . . . . . . . . . . . . . 4
Roof SIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Floor SIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Foundation SIP . . . . . . . . . . . . . . . . . . . . . . . 7
Thermapan Structural Insulated Panels, Inc. • 1380 Commerce Parkway • Fort Erie, Ontario, Canada • L2A 5M4Phone: (905) 994-7399 • Toll-Free: 1-877-443-9255 • Fax: (905) 994-7400 • [email protected] • www.thermapan.com
Table of Contents
3
Exterior Side 7/16” OSBInterior Side 7/16” OSB
Length 8’, 9’, 10’, 12’, 14’, 16’Width 4’Thickness 4.5”, 6.5”, 8.25”R-Value R19, R29, R38Vapor Resistance 2.6 ng/Pam2s - Type 1Air Resistance Yes
Dimensions & Specifications
Wind Pressure, q (KPa)0.35 0.45 0.55 0.65
Wind Load, w (psf)
Panel Height (ft)
14 18 22 26
Maximum Axial Loads (plf)
8 4860 4600 4400 40909 4410 4170 4000 365010 4260 4000 3700 340012 4000 3650 3315 2950
Maximum (Factored) Loads for 4.5” Exterior Wall Panel (L/360)
Wind Pressure, q (KPa)0.35 0.45 0.55 0.65
Wind Load, w (psf)
Panel Height (ft)
14 18 22 26
Maximum Axial Loads (plf)
8 5400 5100 4900 47009 5000 4800 4500 420010 4900 4600 4400 410012 4700 4300 3900 350014 3900 3400 2840 225016 3100 2400 1700
Maximum (Factored) Loads for 6.5” Exterior Wall Panel (L/360)0)
Wind Pressure, q (KPa)0.35 0.45 0.55 0.65
Wind Load, w (psf)
Panel Height (ft)
14 18 22 26
Maximum Axial Loads (plf)
8 5940 5610 5390 51709 5500 5280 4950 462010 5400 5060 4840 451012 5160 4730 4290 385014 4300 3740 3125 247516 3410 2640 1870 1000
Maximum (Factored) Loads for 8.25” Exterior Wall Panel (L/360)
Installation reference:
Thermapan Structural Insulated Panels, Inc. • 1380 Commerce Parkway • Fort Erie, Ontario, Canada • L2A 5M4Phone: (905) 994-7399 • Toll-Free: 1-877-443-9255 • Fax: (905) 994-7400 • [email protected] • www.thermapan.com
Exterior Wall SIP
Notesw = 1.4p (1.4 ULS companion load factor); p = IwqCeCgCp = external pressure (NBC Div. B, 4.1.7.1 (1))
q = q1/50 = velocity pressure from Design Data; Ce = 0.9, CgCp = 1.5
Panel Header Dimensions Maximum Load
Depth (in) Span (ft) Uniform Load (plf) Point Load (lb)
144 1595 31456 615 18608 485 1460
204 1845 37206 800 24008 586 1715
264 2030 40006 972 29158 670 1945
144
Panel Header/Lintel
Panel Header Dimensions Maximum Load
Depth (in) Span (ft) Uniform Load (plf) Point Load (lb)
144 1960 38606 715 21458 570 1715
204 2160 42906 930 27908 680 2000
264 2360 47206 1145 34308 785 2290
Panel Header Dimensions Maximum Load
Depth (in) Span (ft) Uniform Load (plf) Point Load (lb)
144 2345 45756 895 27158 715 2145
204 2675 53606 1160 34308 860 2500
264 2945 58606 1430 43008 985 2860
Note: Maximum (Factored) loads are based on ¼” (6mm) maximum vertical deflection.
Thermapan Structural Insulated Panels, Inc. • 1380 Commerce Parkway • Fort Erie, Ontario, Canada • L2A 5M4Phone: (905) 994-7399 • Toll-Free: 1-877-443-9255 • Fax: (905) 994-7400 • [email protected] • www.thermapan.com
Installation reference: Maximum (Factored) Axial Loads for 4.5” Panel Header/Lintel
Maximum (Factored) Axial Loads for 6.5” Panel Header/Lintel
Maximum (Factored) Axial Loads for 8.25” Panel Header/Lintel
5
Exterior Side 7/16” OSBInterior Side 7/16” OSB
Length 8’, 9’, 10’, 12’, 14’, 16’Width 4’Thickness 6.5”, 8.25”, 10.25”, 12.25”R-Value R29, R38, R48, R58Vapor Resistance 2.6 ng/Pam2s - Type 1Air Resistance Yes
Panel Specifications
Roof SIP
Panel Length or Width (ft)
Panel Thickness
4 8 9 10 12 14 16
Maximum Allowable Overhang
6.5” 1’-4” 2’-8” 3’-0” 3’-3” 3’-3” 3’-3” 3’-3”8.25” 1’-4” 2’-8” 3’-0” 3’-3” 4’-0” 4’-0” 4’-0”10.25” 1’-4” 2’-8” 3’-0” 3’-3” 4’-0” 4’-8” 5’-2”12.25” 1’-4” 2’-8” 3’-0” 3’-6” 4’-3” 5’-0” 5’-6”
1. For maximum (unfactored) loading 60 psf live load + 10 psf dead load.2. Lumber or EWP Splines can be added to obtain certain longer overhangs.
Roof Panel Maximum Overhang Table
MAXIMUM PANEL MAIN SPAN
SUPPORTS
PANEL LENGTH OR WIDTH
ALL DIMENSIONS ALONG SLOPE OF PANEL
MAXIMUM OVERHANG
Panel Thickness
Span (ft)
6.5” 8.25” 10.25” 12.25”FoamSpline
LumberSpline
FoamSpline
LumberSpline
FoamSpline
LumberSpline
FoamSpline
LumberSpline
8 115 140 120 160 125 170 130 185
10 95 120 100 140 105 160 110 17512 70 100 82 125 85 145 90 16514 50 80 65 100 75 135 85 15516 75 65 108 70 125
Maximum loads are factored live and/or snow, plus dead loads (LSD).
Roof Span vs Maximum Load (lbs/sq ft) - (L/360 maximum deflection)
Thermapan Structural Insulated Panels, Inc. • 1380 Commerce Parkway • Fort Erie, Ontario, Canada • L2A 5M4Phone: (905) 994-7399 • Toll-Free: 1-877-443-9255 • Fax: (905) 994-7400 • [email protected] • www.thermapan.com
Installation reference:
SIP Screw Spacing inches (mm)
Resistance - Lateral/Shear lbs/foot (KN/m)
Resistance - Withdrawal/Pullout lbs/foot (KN/m)
24 (600) 200 (2.9) 200 (2.9)20 (500) 250 (3.6) 250 (3.6)16 (400) 300 (4.4) 300 (4.4)12 (300) 400 (5.8) 400 (5.8)10 (250) 480 (6.9) 480 (6.9)8 (200) 600 (8.7) 600 (8.7)
6 (150) 800 (11.6) 800 (11.6)1. Based on 20 lb/sq ft (1 KPa) uplift and 8 lb/sq ft (0.4 KPa) of dead load2. Minimum 1-1/2” (38 mm) fastener penetration into support.3. SIP Screw Maximum Loads (Factored): 400 lb (1.78 KN) Lateral (shear), 400 lb (1.78 KN) Withdrawal (pullout)
Roof Panel Fastener Factored Resistance Table
Exterior Side 7/16” OSBInterior Side 7/16” OSB
Length 8’, 9’, 10’, 12’, 14’, 16’Width 4’Thickness 6.5”, 8.25”, 10.25”, 12.25”R-Value R29, R38, R48, R58Vapor Resistance 2.6 ng/Pam2s - Type 1Air Resistance Yes
Panel Specifications
Panel Thickness
Lumber SplineMaximum Span
L/360Maximum Span
L/4806.5” 2x6 12’-0” 8’-0”
8.25” 2x8 13’-9” 12’-0”10.25” 2x10 15’-4” 14’-0”12.25” 2x12 16’-0” 16’-0”
Uniform 40 psf live load and 10 psf dead load (Standard Term)Total factored load = 73 psfSpans shown are clear distances between supports (1½” mininum end bearing).
Floor Span Table (Vibration Controlled)
6
Panel Thickness
Span (ft) 6.5” 8.25” 10.25” 12.25”
8 140 160 170 18510 120 140 160 17512 100 125 145 16514 80 100 135 15516 108 125
Maximum loads are factored live plus dead loads (LSD).
Maximum Load for Panel Spans:Floor Span vs. Maximum Load (lb/sq ft)
Installation reference:
Thermapan Structural Insulated Panels, Inc. • 1380 Commerce Parkway • Fort Erie, Ontario, Canada • L2A 5M4Phone: (905) 994-7399 • Toll-Free: 1-877-443-9255 • Fax: (905) 994-7400 • [email protected] • www.thermapan.com
Floor SIP
SIP Screw Spacing inches (mm)
Resistance - Lateral/Shear lbs/foot (KN/m)
Resistance - Withdrawal/Pullout lbs/foot (KN/m)
24 (600) 200 (2.9) 200 (2.9)20 (500) 250 (3.6) 250 (3.6)16 (400) 300 (4.4) 300 (4.4)12 (300) 400 (5.8) 400 (5.8)10 (250) 480 (6.9) 480 (6.9)8 (200) 600 (8.7) 600 (8.7)
6 (150) 800 (11.6) 800 (11.6)1. Based on 20 lb/sq ft (1 KPa) uplift and 8 lb/sq ft (0.4 KPa) of dead load2. Minimum 1-1/2” (38 mm) fastener penetration into support.3. SIP Screw Maximum Loads (Factored): 400 lb (1.78 KN) Lateral (shear), 400 lb (1.78 KN) Withdrawal (pullout)
Floor Panel Fastener Factored Resistance Table
7
Exterior Side PWF PlywoodInterior Side PWF Plywood
Length 8’, 9’, 10’Width 4’Thickness 6.5”, 8.25”, 10.25”R-Value R29, R38, R48Vapor Resistance 2.6 ng/Pam2s - Type 1Air Resistance Yes
Panel Specifications
Panel Thickness
Backfill Height (ft)
6.5” 8.25” 10.25”5 ft high
Crawlspace4 ft high
Crawlspace5 ft high
Crawlspace4 ft high
Crawlspace5 ft high
Crawlspace4 ft high
Crawlspace4 3360 4200 4600
3 3480 3440 4350 4300 4800 4700Maximum horizontal deflection is L/360.
Foundation SIP Maximum (Factored) Axial Load Table (lbs/l. ft) - Crawlspace
Installation reference:
Thermapan Structural Insulated Panels, Inc. • 1380 Commerce Parkway • Fort Erie, Ontario, Canada • L2A 5M4Phone: (905) 994-7399 • Toll-Free: 1-877-443-9255 • Fax: (905) 994-7400 • [email protected] • www.thermapan.com
Foundation SIP
Panel Thickness
Backfill Height (ft)
6.5” 8.25” 10.25”9ft high
FoundationWall
8ft high Foundation
Wall
10ft high Foundation
Wall
9ft high Foundation
Wall
8ft high Foundation
Wall
10ft high Foundation
Wall
9ft high Foundation
Wall
8ft high Foundation
Wall9 30258 3700 4040 4100 40707 4300 4485 4800 4325 4525 48206 4815 4915 5115 4880 4955 51605 4200 5200 5000 5200 5300 5100 5300 54004 5000 5400 5200 5400 5500 5300 5500 5600
Maximum horizontal deflection is L/300.
Foundation SIP Maximum (Factored) Axial Load Table (lbs/l. ft) - Basement
1380 Commerce ParkwayFort Erie, Ontario, Canada
L2A 5M4
Phone: (905) 994-7399Toll-Free: 1-877-443-9255
Fax: (905) 994-7400E-mail: [email protected]
www.thermapan.com
Distributed by:
Product Warranty
Thermapan Structural Insulated Panels, Inc. warrants that its products will be free from manufacturing defects or errors in workmanship and material. In addition, the company warrants the adequacy of its design for the normal and expected life of the building, provided the product is correctly installed and used.