Different chemical substances, including the active drug, are combined to produce a final medicinal product.
![Page 3: TESTS ON FORMULATIONS: Content Uniformity, Hardness, Dissolution.](https://reader036.fdocuments.net/reader036/viewer/2022062307/5563b925d8b42a38198b50ec/html5/thumbnails/3.jpg)
![Page 4: TESTS ON FORMULATIONS: Content Uniformity, Hardness, Dissolution.](https://reader036.fdocuments.net/reader036/viewer/2022062307/5563b925d8b42a38198b50ec/html5/thumbnails/4.jpg)
To ensure that every tablet contains the amount of drug substance intended with little variation among tablets within a batch.
![Page 5: TESTS ON FORMULATIONS: Content Uniformity, Hardness, Dissolution.](https://reader036.fdocuments.net/reader036/viewer/2022062307/5563b925d8b42a38198b50ec/html5/thumbnails/5.jpg)
Used for testing the consistencyBulk powdersLiquid orals Also during filling of powders into capsules or liquids
into vials or ampoules Amount of active pharmaceutical ingredient within
individual units of tablets or capsules.
![Page 6: TESTS ON FORMULATIONS: Content Uniformity, Hardness, Dissolution.](https://reader036.fdocuments.net/reader036/viewer/2022062307/5563b925d8b42a38198b50ec/html5/thumbnails/6.jpg)
Measures crushing strength property defined as compressional force applied diametrically to a tablet which just fracture it.
![Page 7: TESTS ON FORMULATIONS: Content Uniformity, Hardness, Dissolution.](https://reader036.fdocuments.net/reader036/viewer/2022062307/5563b925d8b42a38198b50ec/html5/thumbnails/7.jpg)
Limits: 4 kg is considered to be the minimum for satisfactory
tablets. Oral tablets: 4 to 10 kgHypodermic and chewable tablets: 3 kg.Sustained release tablets: 10 to 20 kg.
![Page 8: TESTS ON FORMULATIONS: Content Uniformity, Hardness, Dissolution.](https://reader036.fdocuments.net/reader036/viewer/2022062307/5563b925d8b42a38198b50ec/html5/thumbnails/8.jpg)
Why do we measure Hardness:Need for pressure adjustment on the tableting
machine.Affects the disintegration and dissolution
Factors affecting Hardness:Compression of the tablet and compressive force. Amount of binder. (More binder a more hardness) Method of granulation in preparing the tablet
![Page 9: TESTS ON FORMULATIONS: Content Uniformity, Hardness, Dissolution.](https://reader036.fdocuments.net/reader036/viewer/2022062307/5563b925d8b42a38198b50ec/html5/thumbnails/9.jpg)
Predict in vivo drug release profiles.Test is intended for a capsule or Tablet.Condition maintained:
Temperature: 37 ± 0.5°C
Speed: 25-150 rpm
![Page 10: TESTS ON FORMULATIONS: Content Uniformity, Hardness, Dissolution.](https://reader036.fdocuments.net/reader036/viewer/2022062307/5563b925d8b42a38198b50ec/html5/thumbnails/10.jpg)
BASKET TYPE:Vessel is cylindricalHight: 100-210mmInside diameter: 98-106mmBasket position: the distance between the inside of
bottom vessel & basket maintained at 25 ± 2mm.
![Page 11: TESTS ON FORMULATIONS: Content Uniformity, Hardness, Dissolution.](https://reader036.fdocuments.net/reader036/viewer/2022062307/5563b925d8b42a38198b50ec/html5/thumbnails/11.jpg)
PADDLE TYPE:Vessel is cylindricalHight: 160-210mmInside diameter: 98-160mm.Blade position: distance between the inside bottom of
vessel & the blade is maintained at 25 ± 2mm.
![Page 12: TESTS ON FORMULATIONS: Content Uniformity, Hardness, Dissolution.](https://reader036.fdocuments.net/reader036/viewer/2022062307/5563b925d8b42a38198b50ec/html5/thumbnails/12.jpg)
Apparatus should be chemically inert.Do not adsorb, react or interfere with
dissolution medium.All metal parts of the apparatus must be
made from stainless steel.
![Page 13: TESTS ON FORMULATIONS: Content Uniformity, Hardness, Dissolution.](https://reader036.fdocuments.net/reader036/viewer/2022062307/5563b925d8b42a38198b50ec/html5/thumbnails/13.jpg)
VolumeDeaerationExamples Of Typical Media
![Page 14: TESTS ON FORMULATIONS: Content Uniformity, Hardness, Dissolution.](https://reader036.fdocuments.net/reader036/viewer/2022062307/5563b925d8b42a38198b50ec/html5/thumbnails/14.jpg)
![Page 15: TESTS ON FORMULATIONS: Content Uniformity, Hardness, Dissolution.](https://reader036.fdocuments.net/reader036/viewer/2022062307/5563b925d8b42a38198b50ec/html5/thumbnails/15.jpg)
Above mentioned tests are very essential in order to ensure,
• Constant dose of drug• Sufficient mechanical strength• Released in controlled and reproducible way.
![Page 16: TESTS ON FORMULATIONS: Content Uniformity, Hardness, Dissolution.](https://reader036.fdocuments.net/reader036/viewer/2022062307/5563b925d8b42a38198b50ec/html5/thumbnails/16.jpg)
Bibliography:Indian Pharmacopoeia.