Testing Magnets Installed on EPIRB Brackets

18
1 Testing Magnets Installed on EPIRB Brackets Prepared by Robert G. Garrott CGD Five CFVS Coordinator July 3, 2007

description

Testing Magnets Installed on EPIRB Brackets. Prepared by Robert G. Garrott CGD Five CFVS Coordinator July 3, 2007. Background Information 1. - PowerPoint PPT Presentation

Transcript of Testing Magnets Installed on EPIRB Brackets

Page 1: Testing Magnets Installed on EPIRB Brackets

1

Testing Magnets Installed on EPIRB Brackets

Prepared by Robert G. Garrott

CGD Five CFVS Coordinator

July 3, 2007

Page 2: Testing Magnets Installed on EPIRB Brackets

2

Background Information 1

In 2006, CGD Seven CFVS Coordinator Larry Yarborough and SEC Charleston Lead Examiner Greg Johnson lead a detailed analysis of EPIRB false alerts. They found air and surface sorties triggered by false alerts cost the Coast Guard millions in fuel, personnel and maintenance expenses each year, and that there were two main causes for these false alerts.

Page 3: Testing Magnets Installed on EPIRB Brackets

3

Background Information 2

Modern 406 MHz EPIRBs are designed to automatically activate if removed from their mounting bracket and in contact with water. To reduce false alerts, a magnet mounted in the bracket opens a magnetic reed switch in the EPIRB circuitry. The two most common problems causing false alerts are mounting the EPIRB in the bracket incorrectly, and for the magnet to be missing or out of position.

Page 4: Testing Magnets Installed on EPIRB Brackets

4

Background Information 3

Because they can be placed in the bracket backwards (with the line spool facing out), ACR Satellite EPIRBs are more susceptible to incorrect mounting than other EPIRBs.

Careful attention to Owner’s Manuals and mounting diagrams can prevent false alerts due to incorrect mounting in the bracket.

Page 5: Testing Magnets Installed on EPIRB Brackets

5

Testing for the Magnets

It takes just a few seconds to verify the magnet is properly installed in the bracket. The test device – an inexpensive magnetic compass. The bracket magnet will cause the compass needle to swing and point at the bracket instead of pointing at the magnetic north pole. The following slides show this occurring for several of the most frequently encountered marine EPIRBs.

Page 6: Testing Magnets Installed on EPIRB Brackets

6

Category 1 ACR Satellite2 406 MHz

Page 7: Testing Magnets Installed on EPIRB Brackets

7

Category 1 ACR Satellite2 406 MHz

Page 8: Testing Magnets Installed on EPIRB Brackets

8

Category 2 ACR Satellite2 406 MHz

Page 9: Testing Magnets Installed on EPIRB Brackets

9

Category 2 ACR Satellite2 406 MHz

Page 10: Testing Magnets Installed on EPIRB Brackets

10

Category 1 McMurdo 406 GPS

Note: The magnet is positioned under the EPIRB and is not visible until the EPIRB is removed.

Page 11: Testing Magnets Installed on EPIRB Brackets

11

Category 1 McMurdo 406 GPS

Page 12: Testing Magnets Installed on EPIRB Brackets

12

Category 1 Pains Wessex 406 MHz

Page 13: Testing Magnets Installed on EPIRB Brackets

13

Category 1 Pains Wessex 406 MHz

Page 14: Testing Magnets Installed on EPIRB Brackets

14

Category 2 Pains Wessex 406 MHz

Page 15: Testing Magnets Installed on EPIRB Brackets

15

Category 2 Pains Wessex 406 MHz

Page 16: Testing Magnets Installed on EPIRB Brackets

16

Corrective Action

• Although magnets aren’t mentioned in the regulations, EPIRB design standards require this type of protective feature.

• If the bracket is damaged or the magnet is missing, the defective bracket is not in compliance with 46 CFR 25.26 and must be serviced by an approved EPIRB servicing facility.

Page 17: Testing Magnets Installed on EPIRB Brackets

17

Examiner Action

• Advise the vessel operator that the bracket is defective. Possible negative outcomes:– Early replacement of discharged battery per 46 CFR

25.26-50(c)(1).– Government claims for reimbursing the cost of search

and rescue sorties.

• Issue a worklist item for timely servicing of the defective bracket and follow up.

• Worst case: Request Sector use COTP Order to enforce compliance with 46 CFR 25.26-50(c)(1).

Page 18: Testing Magnets Installed on EPIRB Brackets

18

Boarding Officer Action

• Advise the vessel operator that the bracket is defective. Possible negative outcomes:– Early replacement of discharged battery per 46 CFR

25.26-50(c)(1).– Government claims for reimbursing the cost of search

and rescue sorties.

• Issue a 4100 citation for non-compliant EPIRB and follow up with Sector Lead Examiner.

• Worst case: Request Sector use COTP Order to enforce compliance with 46 CFR 25.26-50(c)(1).