Test Unit Elevations - Wausau Windo INvent... · 2019-05-20 · Elevations Viewed From The Exterior...

21
Elevations Viewed From The Exterior Contact A Wausau Representative For Other Possible Configurations 2250i/3250i/4250i INvent 7 12 9 6 5 8 2 7 12 9 7 6 11 10 3 1 11 17 Opp 10 10 13 AAMA Test Configurations (shown) Architectural AW Class For air, water, cycling and structural Fixed Frame Size Projected Frame Size Casement Frame Size Gateway Sizes Fixed Type D Unit Type D Unit Project-in Hopper Project-out Awning Project-out Casement Project-in Casement Project-out Awning AAMA 12 9 7 4 NFRC 100 Thermal Test Configurations (shown) For U-Factor, SHGC and CR Fixed Frame Size Projected Frame Size Casement Frame Size 4 3 Fixed 6 4 3 Project-in Hopper Project-out Casement Project-in Casement NFRC 1 6 1 13 12 Opp Fixed Fixed Fixed 4 13 60" x 99" 60" x 144" 108" x 60" 60" x 36" 36" x 60" 1524 mm 2515 mm 3658 mm 2743 mm 914 mm Type D Projected Casement Type D 1524 mm 1524 mm x x x x x 1524 mm 1524 mm 914 mm Fixed 59" 47" 59" 24" 59" 24" x x x 1200 mm 600 mm 1500 mm x x x 1500 mm 1500 mm 600 mm Sim Sim Sim Sim Sim Sim Sim Sim Section Contents Page(s) Details P17-2 thru P17-4 Posts and Stacks P17-5 thru P17-7 Glazing Options P17-8 and P17-9 -BHM Blast Mitigation P17-9 -HP Hurricane Impact P17-9 Blind Options P17-10 and P17-11 Simulated Double Hung Accessories P17-16 thru P17-19 Isometric Views P17-20 and P17-21 P17-12 thru P17-15 P17-1 Test Unit Elevations SCALE: Not To Scale Series Architectural Windows © 2015 Apogee Wausau Group, Inc. 2250i/3250i/4250i INvent™

Transcript of Test Unit Elevations - Wausau Windo INvent... · 2019-05-20 · Elevations Viewed From The Exterior...

Page 1: Test Unit Elevations - Wausau Windo INvent... · 2019-05-20 · Elevations Viewed From The Exterior Contact A Wausau Representative For Other Possible Configurations 2250i/3250i/4250i

Elevations Viewed From The Exterior

Contact A Wausau Representative For Other Possible Configurations

2250i/3250i/4250i INvent

7

12

9

6

5

8

2

7

12

9

7

6

11

10

3

1

11

17

Opp

10

10

13

AAMA Test Configurations (shown)

Architectural AW Class

For air, water, cycling and structural

Fixed Frame Size

Projected Frame Size

Casement Frame Size

Gateway Sizes

Fixed

Type D Unit

Type D Unit

Project-in Hopper

Project-out Awning

Project-out Casement

Project-in Casement

Project-out Awning

AAMA

12

9

7

4

NFRC 100 Thermal Test Configurations (shown)

For U-Factor, SHGC and CR

Fixed Frame Size

Projected Frame Size

Casement Frame Size

4

3

Fixed

6

4

3

Project-in Hopper

Project-out

Casement

Project-in

Casement

NFRC

1

6

1

13

12

Opp

Fixed

Fixed

Fixed

4

13

60" x 99"

60" x 144"

108" x 60"

60" x 36"

36" x 60"

1524 mm 2515 mm

3658 mm

2743 mm

914 mm

Type D

Projected

Casement

Type D

1524 mm

1524 mm

x

x

x

x

x

1524 mm

1524 mm

914 mm

Fixed

59"

47"

59"

24"

59"

24"

x

x

x

1200 mm

600 mm

1500 mm

x

x

x

1500 mm

1500 mm

600 mm

Sim

Sim

Sim

Sim

Sim

Sim

Sim

Sim

Section Contents Page(s)

Details P17-2 thru P17-4

Posts and Stacks P17-5 thru P17-7

Glazing Options P17-8 and P17-9

-BHM Blast Mitigation P17-9

-HP Hurricane Impact P17-9

Blind Options P17-10 and P17-11

Simulated Double Hung

Accessories P17-16 thru P17-19

Isometric Views P17-20 and P17-21

P17-12 thru P17-15

P17-1

Test Unit Elevations

SCALE: Not To Scale

Series

Architectural Windows

© 2015 Apogee Wausau Group, Inc.

2250i/3250i/4250i INvent™

Page 2: Test Unit Elevations - Wausau Windo INvent... · 2019-05-20 · Elevations Viewed From The Exterior Contact A Wausau Representative For Other Possible Configurations 2250i/3250i/4250i

5

4

6

3 13/16"

3 5/16"

3 5/16"

2

3

1

3 11/16"

3 3/16"

3 3/16"

2 1/2"

3 1/2"

4 1/2"

4250i Series

3250i Series

2250i Series

2 1/2"

2 1/2"

P17-2

Projected and Fixed Details

SCALE:

Series

Architectural Windows

© 2015 Apogee Wausau Group, Inc.

2250i/3250i/4250i INvent™

6" = 1'-0"

AutoCAD SHX Text
I = 0.731 in^4
AutoCAD SHX Text
(96.84 mm)
AutoCAD SHX Text
995829
AutoCAD SHX Text
995845
AutoCAD SHX Text
805941
AutoCAD SHX Text
805939
AutoCAD SHX Text
805939
AutoCAD SHX Text
805939
AutoCAD SHX Text
(85.7 mm)
AutoCAD SHX Text
189582
AutoCAD SHX Text
995830
AutoCAD SHX Text
995829
AutoCAD SHX Text
805939
AutoCAD SHX Text
(85.7 mm)
AutoCAD SHX Text
995830
AutoCAD SHX Text
995829
AutoCAD SHX Text
995850
AutoCAD SHX Text
980064
AutoCAD SHX Text
995855
AutoCAD SHX Text
995884
AutoCAD SHX Text
I = 0.787 in^4
AutoCAD SHX Text
(88.9 mm)
AutoCAD SHX Text
995827
AutoCAD SHX Text
995841
AutoCAD SHX Text
805939
AutoCAD SHX Text
139985
AutoCAD SHX Text
805947
AutoCAD SHX Text
805939
AutoCAD SHX Text
or
AutoCAD SHX Text
(Cams)
AutoCAD SHX Text
805947
AutoCAD SHX Text
805939
AutoCAD SHX Text
or
AutoCAD SHX Text
(Cams)
AutoCAD SHX Text
805947
AutoCAD SHX Text
805939
AutoCAD SHX Text
or
AutoCAD SHX Text
(Cams)
AutoCAD SHX Text
(81.0 mm)
AutoCAD SHX Text
995827
AutoCAD SHX Text
995832
AutoCAD SHX Text
(81.0 mm)
AutoCAD SHX Text
995827
AutoCAD SHX Text
995832
AutoCAD SHX Text
995847
AutoCAD SHX Text
995847
AutoCAD SHX Text
995851
AutoCAD SHX Text
995853
AutoCAD SHX Text
5115
AutoCAD SHX Text
(63.5 mm)
AutoCAD SHX Text
(88.9 mm)
AutoCAD SHX Text
(114.3 mm)
AutoCAD SHX Text
6039
AutoCAD SHX Text
6040
AutoCAD SHX Text
6040
AutoCAD SHX Text
(63.5 mm)
AutoCAD SHX Text
(63.5 mm)
Page 3: Test Unit Elevations - Wausau Windo INvent... · 2019-05-20 · Elevations Viewed From The Exterior Contact A Wausau Representative For Other Possible Configurations 2250i/3250i/4250i

4 1/2"

7

8

3 11/16"

2 1/2"

3 1/2"

4250i Series

3250i Series

1 7/8"

1 7/8"

2 1/2"

9

2250i Series

P17-3

Projected and Fixed Details

SCALE:

Series

Architectural Windows

© 2015 Apogee Wausau Group, Inc.

2250i/3250i/4250i INvent™

6" = 1'-0"

AutoCAD SHX Text
I = 0.787 in^4
AutoCAD SHX Text
(88.9 mm)
AutoCAD SHX Text
995827
AutoCAD SHX Text
139985
AutoCAD SHX Text
995841
AutoCAD SHX Text
805939
AutoCAD SHX Text
805947
AutoCAD SHX Text
805939
AutoCAD SHX Text
or
AutoCAD SHX Text
(Cams)
AutoCAD SHX Text
805939
AutoCAD SHX Text
995834
AutoCAD SHX Text
(63.5 mm)
AutoCAD SHX Text
(88.9 mm)
AutoCAD SHX Text
(114.3 mm)
AutoCAD SHX Text
(47.6 mm)
AutoCAD SHX Text
995880
AutoCAD SHX Text
805939
AutoCAD SHX Text
(47.6 mm)
AutoCAD SHX Text
(63.5 mm)
AutoCAD SHX Text
995882
AutoCAD SHX Text
995849
AutoCAD SHX Text
995853
AutoCAD SHX Text
995853
AutoCAD SHX Text
5115
Page 4: Test Unit Elevations - Wausau Windo INvent... · 2019-05-20 · Elevations Viewed From The Exterior Contact A Wausau Representative For Other Possible Configurations 2250i/3250i/4250i

10

11 13

12

3 3/16"

1 7/8"3 5/16"

3 13/16"

P17-4

Projected and Fixed Details

SCALE:

Series

Architectural Windows

© 2015 Apogee Wausau Group, Inc.

2250i/3250i/4250i INvent™

6" = 1'-0"

AutoCAD SHX Text
995829
AutoCAD SHX Text
995845
AutoCAD SHX Text
805941
AutoCAD SHX Text
805939
AutoCAD SHX Text
I = 0.731 in^4
AutoCAD SHX Text
805939
AutoCAD SHX Text
5115
AutoCAD SHX Text
805947
AutoCAD SHX Text
805939
AutoCAD SHX Text
or
AutoCAD SHX Text
(Cams)
AutoCAD SHX Text
805939
AutoCAD SHX Text
(81.0 mm)
AutoCAD SHX Text
995827
AutoCAD SHX Text
995832
AutoCAD SHX Text
995834
AutoCAD SHX Text
(47.6 mm)
AutoCAD SHX Text
805939
AutoCAD SHX Text
(85.7 mm)
AutoCAD SHX Text
995834
AutoCAD SHX Text
805941
AutoCAD SHX Text
995829
AutoCAD SHX Text
995847
AutoCAD SHX Text
995849
AutoCAD SHX Text
980064
AutoCAD SHX Text
995853
AutoCAD SHX Text
995867
AutoCAD SHX Text
995853
AutoCAD SHX Text
6039
AutoCAD SHX Text
6040
AutoCAD SHX Text
6040
AutoCAD SHX Text
(88.9 mm)
Page 5: Test Unit Elevations - Wausau Windo INvent... · 2019-05-20 · Elevations Viewed From The Exterior Contact A Wausau Representative For Other Possible Configurations 2250i/3250i/4250i

Fixed / Fixed

Fixed / Fixed Post

15

14

2 3/8"

3 7/8"

1/8"

3250i S

eries

2250i S

eries

4 1/2"

3 1/2"

2 1/2"

4250i S

eries

I-values indicated are for frame members only.

Thermal barrier shear reduction of 10% included.

P17-5

Posts and Stacks

SCALE:

Series

Architectural Windows

© 2015 Apogee Wausau Group, Inc.

2250i/3250i/4250i INvent™

6" = 1'-0"

AutoCAD SHX Text
I = 0.731 in^4
AutoCAD SHX Text
(60.3 mm)
AutoCAD SHX Text
995845
AutoCAD SHX Text
805939
AutoCAD SHX Text
805939
AutoCAD SHX Text
5115
AutoCAD SHX Text
(98.4 mm)
AutoCAD SHX Text
995836
AutoCAD SHX Text
995834
AutoCAD SHX Text
805939
AutoCAD SHX Text
(3.2 mm)
AutoCAD SHX Text
(63.5 mm)
AutoCAD SHX Text
(114.3 mm)
AutoCAD SHX Text
(88.9 mm)
AutoCAD SHX Text
I = 4.569 in^4
AutoCAD SHX Text
I = 2.559 in^4
AutoCAD SHX Text
I = 1.253 in^4
AutoCAD SHX Text
995853
AutoCAD SHX Text
995861
AutoCAD SHX Text
995859
AutoCAD SHX Text
995849
AutoCAD SHX Text
805939
Page 6: Test Unit Elevations - Wausau Windo INvent... · 2019-05-20 · Elevations Viewed From The Exterior Contact A Wausau Representative For Other Possible Configurations 2250i/3250i/4250i

Fixed / Project-Out

Fixed / Project-In

17

16

5 3/16"

5 5/16"

1/8"

1/8"

I-values indicated are for frame members only.

Thermal barrier shear reduction of 10% included.

P17-6

Posts and Stacks

SCALE:

Series

Architectural Windows

© 2015 Apogee Wausau Group, Inc.

2250i/3250i/4250i INvent™

6" = 1'-0"

AutoCAD SHX Text
(131.8 mm)
AutoCAD SHX Text
995827
AutoCAD SHX Text
805939
AutoCAD SHX Text
(3.2 mm)
AutoCAD SHX Text
(134.9 mm)
AutoCAD SHX Text
5115
AutoCAD SHX Text
995829
AutoCAD SHX Text
805939
AutoCAD SHX Text
(3.2 mm)
AutoCAD SHX Text
I = 4.572 in^4
AutoCAD SHX Text
I = 4.336 in^4
AutoCAD SHX Text
I = 2.451 in^4
AutoCAD SHX Text
I = 2.561 in^4
AutoCAD SHX Text
I = 1.266 in^4
AutoCAD SHX Text
I = 1.279 in^4
AutoCAD SHX Text
995861
AutoCAD SHX Text
995851
AutoCAD SHX Text
995861
AutoCAD SHX Text
995855
AutoCAD SHX Text
995847
AutoCAD SHX Text
995859
AutoCAD SHX Text
980064
AutoCAD SHX Text
995859
AutoCAD SHX Text
805947
AutoCAD SHX Text
805939
AutoCAD SHX Text
or
AutoCAD SHX Text
(Cams)
AutoCAD SHX Text
805939
AutoCAD SHX Text
6039
AutoCAD SHX Text
6040
AutoCAD SHX Text
6040
AutoCAD SHX Text
995834
AutoCAD SHX Text
995834
AutoCAD SHX Text
980305
AutoCAD SHX Text
995838
Page 7: Test Unit Elevations - Wausau Windo INvent... · 2019-05-20 · Elevations Viewed From The Exterior Contact A Wausau Representative For Other Possible Configurations 2250i/3250i/4250i

Project-In Vent / Project-In Vent

Project-Out Vent / Project-Out Vent

18

19

6 1/2"

6 3/4"

1/8"

1/8"

I-values indicated are for frame members only.

Thermal barrier shear reduction of 10% included.

P17-7

Posts and Stacks

SCALE:

Series

Architectural Windows

© 2015 Apogee Wausau Group, Inc.

2250i/3250i/4250i INvent™

6" = 1'-0"

AutoCAD SHX Text
(171.5 mm)
AutoCAD SHX Text
(165.1 mm)
AutoCAD SHX Text
995829
AutoCAD SHX Text
805941
AutoCAD SHX Text
995829
AutoCAD SHX Text
995827
AutoCAD SHX Text
995827
AutoCAD SHX Text
805939
AutoCAD SHX Text
(3.2 mm)
AutoCAD SHX Text
(3.2 mm)
AutoCAD SHX Text
I = 4.507 in^4
AutoCAD SHX Text
I = 4.112 in^4
AutoCAD SHX Text
I = 2.561 in^4
AutoCAD SHX Text
I = 2.344 in^4
AutoCAD SHX Text
I = 1.279 in^4
AutoCAD SHX Text
I = 1.266 in^4
AutoCAD SHX Text
805947
AutoCAD SHX Text
805939
AutoCAD SHX Text
or
AutoCAD SHX Text
(Cams)
AutoCAD SHX Text
805947
AutoCAD SHX Text
805939
AutoCAD SHX Text
or
AutoCAD SHX Text
(Cams)
AutoCAD SHX Text
995851
AutoCAD SHX Text
995860
AutoCAD SHX Text
995855
AutoCAD SHX Text
995861
AutoCAD SHX Text
995847
AutoCAD SHX Text
995857
AutoCAD SHX Text
980064
AutoCAD SHX Text
995859
AutoCAD SHX Text
805939
AutoCAD SHX Text
5115
AutoCAD SHX Text
6039
AutoCAD SHX Text
6040
AutoCAD SHX Text
6040
AutoCAD SHX Text
995838
AutoCAD SHX Text
995832
AutoCAD SHX Text
980305
AutoCAD SHX Text
995834
Page 8: Test Unit Elevations - Wausau Windo INvent... · 2019-05-20 · Elevations Viewed From The Exterior Contact A Wausau Representative For Other Possible Configurations 2250i/3250i/4250i

EPDM

6" to 8" Toe Bead at Each Corner

Inside Glazed

1/4" Monolithic Glass

Inside Glazed

1" Spandrel

Preshimmed

Continuous Heel Bead

Glazing Wedge

Outside/Inside Glazed

2" Panel

Inside Glazed

with Silicone Cap

Glazing Tape

Glazing Wedge

Glazing Tape

1" Insulating Glass

Project-Out Fixed and Project-In

EPDM

6" to 8" Toe Bead at Each Corner

with Silicone Cap

Glazing Tape

Glazing Wedge

9/16" Laminated Glass

Inside Glazed

Preshimmed

Preshimmed

6" to 8" Toe Bead at Each Corner

6" to 8" Toe Bead at Each Corner

P17-8

Glazing Options

SCALE:

Series

Architectural Windows

© 2015 Apogee Wausau Group, Inc.

2250i/3250i/4250i INvent™

6" = 1'-0"

AutoCAD SHX Text
(152 mm - 203 mm)
AutoCAD SHX Text
805681
AutoCAD SHX Text
805947
AutoCAD SHX Text
805949
AutoCAD SHX Text
805943
AutoCAD SHX Text
805939
AutoCAD SHX Text
805553
AutoCAD SHX Text
(152 mm - 203 mm)
AutoCAD SHX Text
805950
AutoCAD SHX Text
805975
AutoCAD SHX Text
(Cams)
AutoCAD SHX Text
(152 mm - 203 mm)
AutoCAD SHX Text
(152 mm - 203 mm)
Page 9: Test Unit Elevations - Wausau Windo INvent... · 2019-05-20 · Elevations Viewed From The Exterior Contact A Wausau Representative For Other Possible Configurations 2250i/3250i/4250i

1 1/16" (nom.) Insulating Laminated Glass

Inside Glazed

-BHM Blast Hazard Mitigation

Peak Pressure and Impulse up to 10 psi - 89 psi-msec

Contact Wausau for

blast glazing details

applicable to the

specific requirements

of your project

EPDM

6" to 8" Toe Bead at Each Corner

with Silicone Cap

Glazing Tape

Glazing Wedge

Preshimmed

EPDM

6" to 8" Toe Bead at Each Corner

with Silicone Cap

Glazing Tape

Glazing Wedge

Preshimmed

1 3/16" (nom.) Insulating Laminated Glass

Inside Glazed

1 5/16" (nom.) Insulating Laminated Glass

Inside Glazed

6" to 8" Toe Bead at Each Corner

Glazing Tape

Preshimmed

9/16"

1/2"

1/2"

Structural Silicone Joint

over a Silicone Spacer

with Silicone Cap

Not available in Simulated Double Hung

P17-9

-BHM Blast and -HP Hurricane Glazing Options

SCALE:

Series

Architectural Windows

© 2015 Apogee Wausau Group, Inc.

2250i/3250i/4250i INvent™

6" = 1'-0"

AutoCAD SHX Text
805974
AutoCAD SHX Text
805939
AutoCAD SHX Text
(152 mm - 203 mm)
AutoCAD SHX Text
(152 mm - 203 mm)
AutoCAD SHX Text
(152 mm - 203 mm)
AutoCAD SHX Text
805982
AutoCAD SHX Text
6786
AutoCAD SHX Text
(14.3 mm)
AutoCAD SHX Text
(12.7 mm)
AutoCAD SHX Text
(12.7 mm)
Page 10: Test Unit Elevations - Wausau Windo INvent... · 2019-05-20 · Elevations Viewed From The Exterior Contact A Wausau Representative For Other Possible Configurations 2250i/3250i/4250i

Lift-Out

Elevations Shown As Viewed From The Interior

1" Blind/Dual Glazed

5/8" Blind/Dual Glazed

Hinged

P17-10

Blind Options

SCALE:

Series

Architectural Windows

© 2015 Apogee Wausau Group, Inc.

2250i/3250i/4250i INvent™

6" = 1'-0"

AutoCAD SHX Text
435
AutoCAD SHX Text
434
AutoCAD SHX Text
907001
AutoCAD SHX Text
433
AutoCAD SHX Text
435
AutoCAD SHX Text
907001
AutoCAD SHX Text
805954
AutoCAD SHX Text
805954
AutoCAD SHX Text
805954
AutoCAD SHX Text
805954
AutoCAD SHX Text
805954
AutoCAD SHX Text
or 805967
AutoCAD SHX Text
(cams)
AutoCAD SHX Text
805954
AutoCAD SHX Text
or 805967
AutoCAD SHX Text
(cams)
AutoCAD SHX Text
907001
AutoCAD SHX Text
907001
AutoCAD SHX Text
907001
AutoCAD SHX Text
907001
Page 11: Test Unit Elevations - Wausau Windo INvent... · 2019-05-20 · Elevations Viewed From The Exterior Contact A Wausau Representative For Other Possible Configurations 2250i/3250i/4250i

Hinged

5/8" Blind/Triple Glazed

Elevations Shown As Viewed From The Interior

Lift-Out

P17-11

Blind Options

SCALE:

Series

Architectural Windows

© 2015 Apogee Wausau Group, Inc.

2250i/3250i/4250i INvent™

6" = 1'-0"

AutoCAD SHX Text
907001
AutoCAD SHX Text
434
AutoCAD SHX Text
435
AutoCAD SHX Text
805952
AutoCAD SHX Text
805952
AutoCAD SHX Text
805952
AutoCAD SHX Text
or 805965
AutoCAD SHX Text
(cams)
AutoCAD SHX Text
907001
AutoCAD SHX Text
907001
Page 12: Test Unit Elevations - Wausau Windo INvent... · 2019-05-20 · Elevations Viewed From The Exterior Contact A Wausau Representative For Other Possible Configurations 2250i/3250i/4250i

2"

1

3

2

1

2

Varies

Varies

Panning and mullions are

available in various depths,

with optional historic ogee or

reverse cove profiles. Refer

to "Accessories" for more

information.

4

4250i INvent simulated

double hung windows in

multiple bays must be used in

conjunction with T-mullions or

H-mullions. Side stacking

jambs not available.

1"

Existing window frames

Existing window frames

Panning

T-Mullion

3 5/16"

4 1/2"

P17-12

SCALE:

Series

Architectural Windows

© 2015 Apogee Wausau Group, Inc.

2250i/3250i/4250i INvent™

6" = 1'-0"

Panning and T-Mullions

Simulated Double Hung

AutoCAD SHX Text
(50.8 mm)
AutoCAD SHX Text
841052-IE
AutoCAD SHX Text
841087
AutoCAD SHX Text
(25.4 mm)
AutoCAD SHX Text
995853
AutoCAD SHX Text
805939
AutoCAD SHX Text
995878
AutoCAD SHX Text
805939
AutoCAD SHX Text
139985
AutoCAD SHX Text
980132
AutoCAD SHX Text
(114.3 mm)
AutoCAD SHX Text
(84.1 mm)
AutoCAD SHX Text
5115
AutoCAD SHX Text
6040
AutoCAD SHX Text
6040
AutoCAD SHX Text
Non-stocked items shown - Minimum order quantity may apply
Page 13: Test Unit Elevations - Wausau Windo INvent... · 2019-05-20 · Elevations Viewed From The Exterior Contact A Wausau Representative For Other Possible Configurations 2250i/3250i/4250i

3

2"

6 3/16"

4 1/2"

2"

4

Varies

4 1/2"

1"

1"

Existing window frames

Anchor ends

of mullion

Panning and mullions are

available in various depths,

with optional historic ogee or

reverse cove profiles. Refer

to "Accessories" for more

information.

4250i INvent simulated

double hung windows in

multiple bays must be used in

conjunction with T-mullions

or H-mullions. Side stacking

jambs not available.

P17-13

Panning and T-Mullions

SCALE:

Series

Architectural Windows

© 2015 Apogee Wausau Group, Inc.

2250i/3250i/4250i INvent™

6" = 1'-0"

Simulated Double Hung

AutoCAD SHX Text
651393
AutoCAD SHX Text
860765-IE
AutoCAD SHX Text
863145-IE
AutoCAD SHX Text
5141
AutoCAD SHX Text
(114.3 mm)
AutoCAD SHX Text
(50.8 mm)
AutoCAD SHX Text
(157.2 mm)
AutoCAD SHX Text
(50.8 mm)
AutoCAD SHX Text
841052-IE
AutoCAD SHX Text
(114.3 mm)
AutoCAD SHX Text
(25.4 mm)
AutoCAD SHX Text
(25.4 mm)
AutoCAD SHX Text
995853
AutoCAD SHX Text
805939
AutoCAD SHX Text
980127-IE
AutoCAD SHX Text
805939
AutoCAD SHX Text
980131-IE
AutoCAD SHX Text
995878
AutoCAD SHX Text
805939
AutoCAD SHX Text
761210
AutoCAD SHX Text
5115
AutoCAD SHX Text
6040
AutoCAD SHX Text
6040
AutoCAD SHX Text
Non-stocked items shown - Minimum order quantity may apply
Page 14: Test Unit Elevations - Wausau Windo INvent... · 2019-05-20 · Elevations Viewed From The Exterior Contact A Wausau Representative For Other Possible Configurations 2250i/3250i/4250i

1

3

2

1

2

Head, jamb and sill starters

are available in a number of

face widths and water head

heights. Please refer to

"Series Accessories" for more

information.

4

4250i INvent simulated

double hung windows in

multiple bays must be used in

conjunction with T-mullions or

H-mullions. Side stacking

jambs not available.

Starters

H-Mullion

1 1/2"

1 1/2"

6 psf

4 1/2"

P17-14

Starters and H-Mullions

SCALE:

Series

Architectural Windows

© 2015 Apogee Wausau Group, Inc.

2250i/3250i/4250i INvent™

6" = 1'-0"

Simulated Double Hung

AutoCAD SHX Text
(38.1 mm)
AutoCAD SHX Text
(38.1 mm)
AutoCAD SHX Text
837598
AutoCAD SHX Text
980008
AutoCAD SHX Text
980011
AutoCAD SHX Text
995853
AutoCAD SHX Text
805939
AutoCAD SHX Text
(114.3 mm)
AutoCAD SHX Text
995878
AutoCAD SHX Text
805939
AutoCAD SHX Text
139985
AutoCAD SHX Text
980132
AutoCAD SHX Text
189582
AutoCAD SHX Text
5115
AutoCAD SHX Text
6040
AutoCAD SHX Text
6040
Page 15: Test Unit Elevations - Wausau Windo INvent... · 2019-05-20 · Elevations Viewed From The Exterior Contact A Wausau Representative For Other Possible Configurations 2250i/3250i/4250i

3

4 1/8"

9 5/16"

4 1/2"

4

4250i INvent simulated

double hung windows in

multiple bays must be used in

conjunction with T-mullions

or H-mullions. Side stacking

jambs not available.

Head, jamb and sill starters

are available in a number of

face widths and water head

heights. Please refer to

"Series Accessories" for more

information.

Always use sill

starters below

H-mullions for

secondary water

control.

1 1/2"

4 1/2"

P17-15

Starters and H-Mullions

SCALE:

Series

Architectural Windows

© 2015 Apogee Wausau Group, Inc.

2250i/3250i/4250i INvent™

6" = 1'-0"

Simulated Double Hung

AutoCAD SHX Text
(114.3 mm)
AutoCAD SHX Text
(104.8 mm)
AutoCAD SHX Text
(236.5 mm)
AutoCAD SHX Text
(38.1 mm)
AutoCAD SHX Text
837598
AutoCAD SHX Text
980008
AutoCAD SHX Text
995853
AutoCAD SHX Text
805939
AutoCAD SHX Text
(114.3 mm)
AutoCAD SHX Text
994870-IE
AutoCAD SHX Text
805939
AutoCAD SHX Text
980128
AutoCAD SHX Text
995878
AutoCAD SHX Text
805939
AutoCAD SHX Text
980132
AutoCAD SHX Text
5115
AutoCAD SHX Text
6040
AutoCAD SHX Text
6040
AutoCAD SHX Text
Non-stocked items shown - Minimum order quantity may apply
Page 16: Test Unit Elevations - Wausau Windo INvent... · 2019-05-20 · Elevations Viewed From The Exterior Contact A Wausau Representative For Other Possible Configurations 2250i/3250i/4250i

Other Sill Starters Available For Higher Water Test Pressures

Value in psf Indicates Approximate Water Head Performance

2250i Sill Starter

2250i Head & Jamb Starter

1 1/2"

1 1/2"

6 psf

3250i Head & Jamb Starter

1 1/2"

3250i Sill Starter

4250i Head & Jamb Starter

1 1/2"

4250i Sill Starter

2 1/4" 10 psf

3 1/4"

15 psf

P17-16

Head, Jamb and Sill Starters

SCALE:

Series

Architectural Windows

© 2015 Apogee Wausau Group, Inc.

2250i/3250i/4250i INvent™

6" = 1'-0"

Accessories

AutoCAD SHX Text
(38.1 mm)
AutoCAD SHX Text
(38.1 mm)
AutoCAD SHX Text
980009
AutoCAD SHX Text
837598
AutoCAD SHX Text
980006
AutoCAD SHX Text
(38.1 mm)
AutoCAD SHX Text
837598
AutoCAD SHX Text
980007
AutoCAD SHX Text
(38.1 mm)
AutoCAD SHX Text
837598
AutoCAD SHX Text
980008
AutoCAD SHX Text
(57.2 mm)
AutoCAD SHX Text
980013
AutoCAD SHX Text
(82.6 mm)
AutoCAD SHX Text
980017
Page 17: Test Unit Elevations - Wausau Windo INvent... · 2019-05-20 · Elevations Viewed From The Exterior Contact A Wausau Representative For Other Possible Configurations 2250i/3250i/4250i

1/8" (nom.) Formed Steel

2250i Slide-In Anchor

3/16" (nom.) Formed Steel

3250i Heavy Duty Slide-In Anchor

3/16" (nom.) Formed Steel

4250i Heavy Duty Slide-In Anchor

P17-17

Anchors

SCALE:

Series

Architectural Windows

© 2015 Apogee Wausau Group, Inc.

2250i/3250i/4250i INvent™

6" = 1'-0"

Accessories

AutoCAD SHX Text
141861
AutoCAD SHX Text
426
AutoCAD SHX Text
141860
AutoCAD SHX Text
141860
AutoCAD SHX Text
571
AutoCAD SHX Text
572
Page 18: Test Unit Elevations - Wausau Windo INvent... · 2019-05-20 · Elevations Viewed From The Exterior Contact A Wausau Representative For Other Possible Configurations 2250i/3250i/4250i

PVC Caulk Backers

2250i

3250i

4 1/4"

Trim to Fit

Frame Extender

4250i

P17-18

Frame Extenders and Caulk Backers

SCALE:

Series

Architectural Windows

© 2015 Apogee Wausau Group, Inc.

2250i/3250i/4250i INvent™

6" = 1'-0"

Accessories

AutoCAD SHX Text
426
AutoCAD SHX Text
572
AutoCAD SHX Text
571
AutoCAD SHX Text
836075-IE
AutoCAD SHX Text
(108.0 mm)
AutoCAD SHX Text
Non-stocked items shown - Minimum order quantity may apply
Page 19: Test Unit Elevations - Wausau Windo INvent... · 2019-05-20 · Elevations Viewed From The Exterior Contact A Wausau Representative For Other Possible Configurations 2250i/3250i/4250i

Nailing Fin

Exterior Anchor

P17-19

SCALE:

Series

Architectural Windows

© 2015 Apogee Wausau Group, Inc.

2250i/3250i/4250i INvent™

6" = 1'-0"

Optional Nailing Fin Anchor

Accessories

AutoCAD SHX Text
907662
AutoCAD SHX Text
823919-IE
AutoCAD SHX Text
995853
AutoCAD SHX Text
Non-stocked items shown - Minimum order quantity may apply
Page 20: Test Unit Elevations - Wausau Windo INvent... · 2019-05-20 · Elevations Viewed From The Exterior Contact A Wausau Representative For Other Possible Configurations 2250i/3250i/4250i

2250i INvent Series Shown

-XLT Similar

Key:

Extruded Aluminum Head And Jamb Starter

With Polyamide Thermal Barrier

Extruded Aluminum Sill Starter

With Polyamide Thermal Barrier

Drive-On Starter Strip

Structural Attachment

Field Seal All Fastener Heads

Erector Installed Full-Bearing Shims

Aluminum Splices With Bond Breaker

Tape - Erector Set In Sealant and Exterior

Aluminum Splice - Erector

Erector Installed And Tooled

Foam Baffle Weep Back-Up

Perimeter Sealant Joint,

May Vary Per Conditions -

Set In Sealant

Specified Sealant And Backer Rod

Insulation

Stone Lintel

Brick

Interior Concrete Block

Conditions Vary...

Note: Installation

Precast

Brick Over Block

Applied Sealant Joint

Expansion / Splice Joint

1

2

3

4

5

6

7

8

9

10

11

12

13

14

3

1

6

4

5

1

4

3

2

8

7

5

9

10

10

12

11

10

14

11

13

10

P17-20

Exploded Starter System Installation

SCALE: Not To Scle

Series

Architectural Windows

© 2015 Apogee Wausau Group, Inc.

2250i/3250i/4250i INvent™

Page 21: Test Unit Elevations - Wausau Windo INvent... · 2019-05-20 · Elevations Viewed From The Exterior Contact A Wausau Representative For Other Possible Configurations 2250i/3250i/4250i

Frames

Extruded Frame Extender

(When Required)

PVC Caulk Backer

Specified Rod And Perimeter Sealant

Anchorage (Using Slide-In Anchors)

Stainless Steel Fasteners Suitable

For Substrate Material

Steel Slide-In Anchor With Fasteners

(When Required At 3 1/2" And 4 1/2" Depth Systems)

Perimeter Conditions

May Vary

Erector Dead Load Shim

Flashing

Brick

Perimeter

Insulation

Frame And Adjacent Walls

Always Maintain Vapor Barrier Between

Secure Attachment Into Steel Studs

General Contractor Provide Blocking To

Cavity Wall

Erector Installed Full-Bearing Shim

1

2

3

4

5

6

7

8

9

10

11

12

8

9

7

3

2

3

6

5

4

3

1

10

11

12

2250i INvent Series Shown

-XLT Similar

P17-21

Exploded Window Installation

SCALE: Not To Scale

Series

Architectural Windows

© 2015 Apogee Wausau Group, Inc.

2250i/3250i/4250i INvent™