TEST RESULTS - Home - Rainbow Technology

36
Product Literature TELCORDIA – DA- 2043, Volume 1 “Features, Functions and Performance Analysis of the Rainbow Technology Telco and Power -Wasp and Ant Spray.” Tests performed in accordance to BELLCORE/TELCORDIA – TR-620-23352-84-03 NEETRAC TEST/Southern Development Stress Cracking and Compatibility with Power/ Electrical Cable and Equipment Components. Product SDS 1-800-637-6047 RAINBOW TECHNOLOGY CORPORATION 261 Cahaba Valley Parkway Pelham, AL 35124-1146 FAX: 1-800-521-6896 www.rainbowtech.net TEST RESULTS 88500 TELCO & POWER WASP & ANT SPRAY with ETOC ® Rev. April 2016

Transcript of TEST RESULTS - Home - Rainbow Technology

Page 1: TEST RESULTS - Home - Rainbow Technology

• Product Literature

• TELCORDIA – DA- 2043, Volume 1 “Features,Functions and Performance Analysis of theRainbow Technology Telco and Power -Wasp andAnt Spray.” Tests performed in accordance toBELLCORE/TELCORDIA – TR-620-23352-84-03

• NEETRAC TEST/Southern Development –Stress Cracking and Compatibility with Power/Electrical Cable and Equipment Components.

• Product SDS

1-800-637-6047

RAINBOW TECHNOLOGY CORPORATION261 Cahaba Valley ParkwayPelham, AL 35124-1146FAX: 1-800-521-6896www.rainbowtech.net

TEST RESULTS88500 TELCO & POWER WASP & ANT SPRAY with ETOC®

Rev. April 2016

Page 2: TEST RESULTS - Home - Rainbow Technology
Page 3: TEST RESULTS - Home - Rainbow Technology

®

UNLIKE VIRTUALLY ALL OTHER WASP SPRAYS, TELCO & POWER WASP & ANT SPRAY with ETOC® does NOT crack and craze plastics used in utility and telecom equipment. (Bellcore) Telcordia and NEETRAC testing show it to be safe for plastics. When metals were tested per (Bellcore) Telcordia specifications, TELCO & POWER WASP & ANT SPRAY with ETOC® was found to be non-corrosive. In additional NEETRAC testing, this insecticide product has been safely tested on rubber elbows and cable joint compounds.

Because our spray contains one of the most powerful active ingredients, it quickly knocks down flying and stinging insects. This superior solvent-based product is SAFE for use on and in utility and telecom equipment.

TELCO & POWER WASP & ANT SPRAY with ETOC® has the highest dielectric strength (48.1 kV) available to ensure greater safety when working around medium to high voltage. This is especially important considering the common practice of utilities and telecoms sharing poles.

TELCO & POWER WASP & ANT SPRAY with ETOC® EXCEEDS the strictest wasp spray specifications ever developed. Many people have highly allergic - even life-threatening - reactions to bites and stings. Using this long-range spray also helps avoid injuries while trying to escape from insect attack.

The high-output spray pattern delivers a high percentage of the formula to the target from a safe distance of 12 to 15 feet. The actuator or spray button is designed with an upward angle of 15 degrees to make it easier to hit the target. A unique locking mechanism keeps the spray button in place and ready to use.

TELCO & POWER WASP & ANT SPRAY

88500PRODUCT:

THE BASICS:

TELCO & POWER WASP & ANT SPRAY

With ETOC®

With ETOC®

FEATURES HOW YOU BENEFIT

Contains a powerful, fast-acting active ingredient

Effective 12 to 15 foot spray pattern

Very high dielectric strength (48.1 kV) and high flash point (>200ºF)

Safe for use with plastics such as ABS, Noryl, Polycarbonate, and Polyethylene. Also safe on rubber elbows and cable joint compounds

Quick and effective insect knockdown

Employee can effectively saturate target from a safe distance

Employee safety because of reduced probability of electric shock

Will NOT damage equipment

Page 4: TEST RESULTS - Home - Rainbow Technology

®

RELATED PRODUCTS:

SAFETY DATA SHEET:

PACKAGING:

ANSWERS TO YOUR QUESTIONS:

DISTRIBUTED BY

PRODUCT CONTAINER UNITS/ CASE CASE SIZE NUMBER SIZE CASE WEIGHT L x W x H 88500 20 oz Aerosol 12 13 lbs 12” x 9” x 10.5”

This product is only for sale to and use by service personnel. SDS available on request.

Rainbow Technology offers a comprehensive line of products to the utility and telecommunications industries. Users of TELCO & POWER WASP & ANT SPRAY with ETOC® often find these other Rainbow products helpful too.

Rainbow Technology has confidence in the quality and effectiveness of our products. We test our products to confirm that they will do what we say they will do. TELCO & POWER WASP & ANT SPRAY with ETOC® meets the most difficult wasp spray specifications ever developed. You may request a copy of the (Bellcore) Telcordia Technical Reference (TR-620-23352-84-03), Issue 1, August 1984 “Wasp and Hornet Spray.” TELCO & POWER WASP & ANT SPRAY with ETOC® is an EPA-registered product. For employee safety training, Rainbow has developed an entertaining and comprehensive video entitled, “Stinging Insects in the Workplace.” Please inquire.

TELCO & POWER WASP & ANT SPRAY with ETOC® controls so many different flying and crawling insects, it can reduce the total number of products you need. Use it to control all these flying and crawling insects:

Insect Probe (4357)Fire Ant & Insect Killer (4480, 4483, 4484)Jungle Formula Insect Repellent (4501)KNUCKLES Hand & Tool Cleaning Towels (79315, 79316)Multi-Bug Killer (4336)Multi-Bug III (4340)Can Holster (70604)Mice & Rat Bait (4025)Havoc® Bait Packs (43550)

l Waspsl Hornetsl Antsl Fire Antsl Yellow Jackets

l Bees and Spidersl Black Widow Spidersl Brown Recluse Spidersl Argentine Antsl Brown Dog Ticks

Do you have a question about any Rainbow Technology product? Because we’ve been supplying the utility and telecommunications industries since 1971, our technical support team has the expertise to provide answers and solutions.Just call us at 1.800.637.6047.

RAINBOW TECHNOLOGYSpecialists in Utility Chemicals

Correspondence: PO Box 26445 Birmingham, AL 35260-0445

Shipping: 261 Cahaba Valley Parkway Pelham, AL 35124-1146

Phone: 1.800.637.6047 or 1.205.733.0333 Fax: 1.800.521.6896 or 1.205.733.8930 E-mail: [email protected] Website: www.rainbowtech.net

APPLICATIONS:

TECHNICAL HIGHLIGHTS:

8850

0-A

l Cockroachesl Cricketsl Fliesl Fleasl Scorpions

Page 5: TEST RESULTS - Home - Rainbow Technology

Features, Functions and Performance Analysis of the Rainbow Technology Telco and Power -Wasp and Ant Spray

Telcordia Distributable Technical Analysis Report

DA- 2043, Volume 1 Issue 1 October 2013

Telcordia Technology Inc Confidential – Restricted Access This document and the confidential information it contains shall be distributed, routed or made available solely to authorized persons having a need to know within Telcordia, except with written permission of Telcordia

Page 6: TEST RESULTS - Home - Rainbow Technology

Rainbow Technology Telco and Power - Wasp and Ant Spray

Telcordia Technology, Inc Confidential – Restricted Access

See confidential restrictions on title page

2

DA-2043, Volume 1 Issue 1

October 2013

Features, Functions and Performance Analysis of Rainbow Technology Telco and Power - Wasp and Ant Spray

This document was prepared by:

Ernie Gallo Network Deployment, Reliability and Quality Services Room RRC 4D644 444 Hoes Lane Piscataway, NJ 08854 [email protected]

For more information, contact Telcordia Technology at +1.732.699.5800 or visit our web site at www.telcordia,.com

Copyright © 2013 Telcordia Technology, Inc. All rights reserved

Trademark Acknowledgements

Telcordia is a trademark of Telcordia Technology, Inc.

Page 7: TEST RESULTS - Home - Rainbow Technology

Rainbow Technology Telco and Power - Wasp and Ant Spray

Telcordia Technology, Inc Confidential – Restricted Access

See confidential restrictions on title page

3

DA-2043, Volume 1 Issue 1

October 2013

Distributable Technical Analysis Report Notice of Disclaimer

This Technical Analysis Report is the property of Telcordia Technology, Inc. (Telcordia), and has been prepared at the request of and pursuant to an agreement with Rainbow Technology Corporation (the “Customer”), only for the internal use of the Customer, Telcordia and Authorized Recipients of the Report. Telcordia hereby licenses the Customer to use and distribute the report solely to its personnel and to Authorized Recipients.

“Authorized Recipients” are persons who have rightfully received the Report directly from the Customer, and who have accepted the limitations: (1) that the Report may be used only for the Recipient’s internal use; (2) that the Report may not be disclosed further. No other persons are authorized to have or to use this Report for any purpose. Neither this report nor any of its contents should be disclosed by a Recipient to persons other than its own employees.

Unless otherwise stated in the Report, this Report analyzes a product or process against criteria, which may include criteria derived from referenced standards, proposed Telcordia generic requirements and/or the Customer’s own specifications.

The analysis and the conclusions expressed herein relate only to the time at which the analysis was performed and the limited set of facts and assumptions set forth in this Report. Product and process specifications may change from time to time, and those and other actions over which Telcordia has no control may render the conclusions of this Report inapplicable or inaccurate for the reader’s purposes. The reader should obtain current information relevant to the reader’s needs directly from the Customer or the manufacturer of the analyzed product.

The conclusions expressed in this Report are subject to change without notice as is the information on which such conclusions are based.

The reader is advised that units of an analyzed product may vary substantially from the unit or units Telcordia analyzes, and changes in the product, in its environment or in its installation, maintenance or use may cause substantial variations in performance, rendering this Report inapplicable to the reader’s needs and situation. The reader is also advised that analyzed processes may change rendering this Report inapplicable to the reader’s needs and situation. These are matters beyond the control and responsibility of Telcordia.

Page 8: TEST RESULTS - Home - Rainbow Technology

Rainbow Technology Telco and Power - Wasp and Ant Spray

Telcordia Technology, Inc Confidential – Restricted Access

See confidential restrictions on title page

4

DA-2043, Volume 1 Issue 1

October 2013

This document is not to be construed as a suggestion to any equipment manufacturer to modify or change any of its products or processes nor does this document constitute or imply any commitment by Telcordia or any other person or entity to purchase any product.

Telcordia reserves the right to revise this document for any reason.

LIABILITY TO ANYONE ARISING FROM USE OF OR RELIANCE UPON ANY INFORMATION SET FORTH HEREIN IS EXPRESSLY DISCLAIMED, AND NO REPRESENTATIONS OR WARRANTIES, EXPRESS OR IMPLIED, ARE MADE WITH RESPECT TO THE ACCURACY OR UTILITY OF ANY ANALYSIS, STATEMENT OR INFORMATION SET FORTH HEREIN.

TELCORDIA MAKES NO WARRANTY OR GUARANTY AS TO THE QUALITY, CHARACTER, PERFORMANCE OR CONDITION OF THE CUSTOMER’S PRODUCTS, PROCESSES OR SERVICES ANALYZED IN THIS REPORT, INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OR GUARANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TELCORDIA FURTHER DISCLAIMS ANY LIABILITY FOR ANY DAMAGE, DIRECT OR INDIRECT, SPECIAL OR CONSEQUENTIAL, SUFFERED AS A RESULT OF RELIANCE ON THIS REPORT. TELCORDIA DOES NOT WARRANT OR GUARANTY PRODUCTS, PROCESSES OR SERVICES. FURTHER, NOTHING CONTAINED HEREIN IS INTENDED OR SHOULD BE UNDERSTOOD AS A RECOMMENDATION, APPROVAL, CERTIFICATION, WARRANTY, GUARANTY OR ENDORSEMENT OF ANY PRODUCTS, PROCESSES OR SERVICES TO ANYONE.

Page 9: TEST RESULTS - Home - Rainbow Technology

Rainbow Technology Telco and Power - Wasp and Ant Spray

Telcordia Technology, Inc Confidential – Restricted Access

See confidential restrictions on title page

5

DA-2043, Volume 1 Issue 1

October 2013

Analysis Scope Notice

Telcordia Technology has reviewed the product class for the Rainbow Technology Wasp and Ant Spray using the ETOC formula. This is a limited technical analysis that reviewed the following requirements from Telcordia TR-620-23352-84-03, Wasp and Hornet Spray, Issue 1, August 1984 (“TR-620”):

Label Marking (Section 3.5 of TR-620)

Material Safety Data Sheet (MSDS) (Section 3.6 of TR-620)

Chemical Resistance (Section 4.4 of TR-620)

Packaged Aerosol Tests – Safety /Flammability (Section 5.3C of TR-620)

Packaged Aerosol Tests – Safety /Flashpoint (Section 5.3D of TR-620)

Packaged Aerosol Tests – Chemical /Stress Cracking of Polyethylene

(Section 5.4A of TR-620)

Packaged Aerosol Tests – Chemical /Stress Cracking of Polycarbonate

(Section 5.4B of TR-620)

Packaged Aerosol Tests – Chemical /Stress Cracking of Modified-PPO

Resins (Section 5.4C of TR-620)

Packaged Aerosol Tests – Chemical /Stress Cracking of ABS (Section

5.4D of TR-620)

Packaged Aerosol Tests – Corrosion of Copper – Copper Mirror (Section

5.4E of TR-620)

Telcordia conducted the Chemical /Stress Cracking of Polyethylene at our Piscataway, NJ testing laboratory on test bars and spray provided by Rainbow Technology. All other test data used in the analysis was conducted at Dallas Laboratories, Inc. 1323 Wall Street Dallas, Texas 75315 Phone +1.214.565.0593 and provided to Telcordia by Rainbow Technology.Telcordia did not validate the Dallas Laboratories test data. Label marking anddata sheets were provided to Telcordia by Rainbow Technology.

Additional information on the product testing can be found in Telcordia Technical Audit Report AU-NWT-000015 Issue 1, February 1992 titled Rainbow Technology Wasp and Ant Spray #4354.

Vic
Highlight
Page 10: TEST RESULTS - Home - Rainbow Technology

Rainbow Technology Telco and Power - Wasp and Ant Spray

Telcordia Technology, Inc Confidential – Restricted Access

See confidential restrictions on title page

6

DA-2043, Volume 1 Issue 1

October 2013

Contacts

Ernie Gallo Larry Joe Steeley, Jr. Telcordia Rainbow Technology Corporation 444 Hoes Lane, Room 4D644 261 Cahaba Valley Pkwy Piscataway, NJ 08854 Pelham, AL 35124 Phone: + 1.732.699.3312 Phone + 1.800.637.6047 E-mail: [email protected] Email:[email protected]

Product Description

Rainbow Telco & Power Wasp & Ant Spray (ETOC formula) is intended to be used by telecommunication technicians and is intended kill flying and stinging insects while not harming the telecommunications plant or equipment.

Vic
Highlight
Page 11: TEST RESULTS - Home - Rainbow Technology

Rainbow Technology Telco and Power - Wasp and Ant Spray

Telcordia Technology, Inc Confidential – Restricted Access

See confidential restrictions on title page

7

DA-2043, Volume 1 Issue 1

October 2013

Table of Contents

1. Analysis Results

1.1 Label Marking (Section 3.5 of TR-620) – Page 9

1.2 Material Safety Data Sheet (MSDS) (Section 3.6 of TR-620) – Page 12

1.3 Chemical Resistance (Section 4.4 of TR-620) – Page 16

1.4 Packaged Aerosol Tests – Safety /Flammability (Section 5.3C of TR-620) – Page 16

1.5 Packaged Aerosol Tests – Safety /Flashpoint (Section 5.3D of TR-620) – Page 17

1.6 Packaged Aerosol Tests – Chemical /Stress Cracking of Polyethylene (Section 5.4A of TR-620) – Page 18

1.7 Packaged Aerosol Tests – Chemical /Stress Cracking of Polycarbonate (Section 5.4B of TR-620) – Page 18

1.8 Packaged Aerosol Tests – Chemical /Stress Cracking of Modified-PPO Resins (Section 5.4C of TR-620) – Page 19

1.9 Packaged Aerosol Tests – Chemical /Stress Cracking of ABS (Section 5.4D of TR-620) – Page 19

1.10 Packaged Aerosol Tests – Corrosion of Copper – Copper Mirror (Section 5.4E of TR-620) – Page 19

Figure 1: Samples Polyethylene Test Bars in a 3 point test fixture – Page 21

Figure 2: Samples with ABS, Polycarbonate and Modified PPO Test Bars in a 3 point test fixture – Page 22

Figure 3: Sprayed samples with ABS Test Bars in a 3 point test fixture after exposure – Page 23

Figure 4: Sprayed samples with Polycarbonate Test Bars in a 3 point test fixture after exposure – Page 24

Figure 5: Sprayed samples with Modified PPO Test Bars in a 3 point test fixture after exposure – Page 25

Figure 6: Dallas Laboratories Test Report October 20, 2013 – Page 26

Page 12: TEST RESULTS - Home - Rainbow Technology

Rainbow Technology Telco and Power - Wasp and Ant Spray

Telcordia Technology, Inc Confidential – Restricted Access

See confidential restrictions on title page

8

DA-2043, Volume 1 Issue 1

October 2013

Figure 7: Dallas Laboratories Test Report April 17, 2012 – Page 27

Page 13: TEST RESULTS - Home - Rainbow Technology

Rainbow Technology Telco and Power - Wasp and Ant Spray

Telcordia Technology, Inc Confidential – Restricted Access

See confidential restrictions on title page

9

DA-2043, Volume 1 Issue 1

October 2013

1. Analysis Results

1.1 Label Marking (Section 3.5 of TR-620)

Requirements included here are derived from the Chemical Specialties

Manufacturers Association (CSMA) Aerosol Guide. The purpose of the listing is

to provide insight as to what is required on insecticide product labels. It

should be noted that labeling information may be regulated by many agencies

and these requirements may change without notice. It is the responsibility of

the supplier to complete with current local, state and federal regulatory

requirements.

A. Labeling Requirements

1. Name and principal business address of supplier

2. Net weight of product

3. Product run code

4. EPA Registration Number and EPA Establishment Number

5. List of ingredients by chemical name and CAS No. and percentage of

weight

6. Directions for safe use

7. Other pertinent information.

Page 14: TEST RESULTS - Home - Rainbow Technology

Rainbow Technology Telco and Power - Wasp and Ant Spray

Telcordia Technology, Inc Confidential – Restricted Access

See confidential restrictions on title page

10

DA-2043, Volume 1 Issue 1

October 2013

B. Required Precautions and/or warnings

1. Storage directions

2. Flammability rating

3. Pressure warning

4. Skin or eye contact precautions

5. Ingestion precautions

6. Disposal instructions

7. First aid instructions

Results: The product is marked with appropriate instructions.

Page 15: TEST RESULTS - Home - Rainbow Technology

Rainbow Technology Telco and Power - Wasp and Ant Spray

Telcordia Technology, Inc Confidential – Restricted Access

See confidential restrictions on title page

11

DA-2043, Volume 1 Issue 1

October 2013

Conforms

Page 16: TEST RESULTS - Home - Rainbow Technology

Rainbow Technology Telco and Power - Wasp and Ant Spray

Telcordia Technology, Inc Confidential – Restricted Access

See confidential restrictions on title page

12

DA-2043, Volume 1 Issue 1

October 2013

1.2 Material Safety Data Sheet (MSDS) (Section 3.6 of TR-620)

An MSDS or OSHA-20 form is required to be submitted to the operating company prior to product shipment to be kept on file. Any change in raw materials, formulation, or specification requirements will require the submission of a revised MSDS or OSHA-20 Form.

Results: The product is provided with an appropriate safety data sheet.

Page 17: TEST RESULTS - Home - Rainbow Technology

Rainbow Technology Telco and Power - Wasp and Ant Spray

Telcordia Technology, Inc Confidential – Restricted Access

See confidential restrictions on title page

13

DA-2043, Volume 1 Issue 1

October 2013

Page 18: TEST RESULTS - Home - Rainbow Technology

Rainbow Technology Telco and Power - Wasp and Ant Spray

Telcordia Technology, Inc Confidential – Restricted Access

See confidential restrictions on title page

14

DA-2043, Volume 1 Issue 1

October 2013

Page 19: TEST RESULTS - Home - Rainbow Technology

Rainbow Technology Telco and Power - Wasp and Ant Spray

Telcordia Technology, Inc Confidential – Restricted Access

See confidential restrictions on title page

15

DA-2043, Volume 1 Issue 1

October 2013

Conforms

Page 20: TEST RESULTS - Home - Rainbow Technology

Rainbow Technology Telco and Power - Wasp and Ant Spray

Telcordia Technology, Inc Confidential – Restricted Access

See confidential restrictions on title page

16

DA-2043, Volume 1 Issue 1

October 2013

1.3 Chemical Resistance (Section 4.4 of TR-620)

Chemical Requirements

A. Stress Cracking. Based on the tests outlined in Section 5.4 of TR-620, the

following plastics must be attached by a candidate product at a strain level

less than or equal to 0.075 percent.

Polyethylene

Polycarbonate

Modified PPO Resins

ABS

Results: Review of the data provided by Dallas Laboratories, indicated there was no evidence of stress cracking Polycarbonate, Modified PPO Resins and ABS as a result of the test exposure. Polyethylene was tested at Telcordia Technology Piscataway, NJ test laboratory.

Conforms

1.4 Packaged Aerosol Tests – Safety /Flammability (Section 5.3C of TR-620)

C. Flammability. Test per ASTM D 3065.

1. Report the flame projection.

2. Report of flashback performance.

Results: Review of the data provided by Dallas Laboratories, indicated there was no flame extension.

Conforms

Page 21: TEST RESULTS - Home - Rainbow Technology

Rainbow Technology Telco and Power - Wasp and Ant Spray

Telcordia Technology, Inc Confidential – Restricted Access

See confidential restrictions on title page

17

DA-2043, Volume 1 Issue 1

October 2013

1.5 Packaged Aerosol Tests – Safety /Flashpoint (Section 5.3D of TR-620)

D. Flashpoint. Test per ASTM D 1310. The flashpoint of the product perSection 4.3 Safety shall be greater than 140°F

Results: Review of the data provided by Dallas Laboratories indicated a flashpoint of 222°F

Conforms

Page 22: TEST RESULTS - Home - Rainbow Technology

Rainbow Technology Telco and Power - Wasp and Ant Spray

Telcordia Technology, Inc Confidential – Restricted Access

See confidential restrictions on title page

18

DA-2043, Volume 1 Issue 1

October 2013

1.6 Packaged Aerosol Tests – Chemical /Stress Cracking of Polyethylene (Section 5.4A of TR-620)

A. Stress Cracking of Polyethylene The wasp and hornet spray shall be tested toevaluate its effect on the cracking of polyethylene. Use the procedure outlinedin Section 5.4B except that polycarbonate is replaced with a polyethylene.

Results: Review of the testing conducted by Telcordia, indicated there was no evidence of stress cracking of Polyethylene as a result of the test exposure.

Conforms

1.7 Packaged Aerosol Tests – Chemical /Stress Cracking of Polycarbonate (Section 5.4B of TR-620)

B. Stress Cracking of Polycarbonate. The wasp and hornet spray shall be testedto evaluate its effect on the cracking of polycarbonate as follows.

1. Test samples – Injected molded bars 5” x 1/2” X 1/8”, shall beprepared using clean, dry polycarbonate with a melt flow (ASTM D1238, Procedure A, Condition 0) of 6-12 g/10 minutes. The bars shall becut in half to sample 2- 1/2” x 1/2 “ x 1/8”, heated in an air circulatingoven for 24 hours at 120C, and then allowed to cool to roomtemperature.

2. Samples shall be bent in a three-point bending fixture to yield anouter fiber strain of 0.0075 in./in. Five samples shall be prepared.

3. The stressed samples in the fixture shall be sprayed with the productand allowed to stand for 48 hours at room temperature.

4. No crazing or cracking of the test specimen shall occur after two daysat room temperature.

Results: Review of the data provided by Dallas Laboratories, indicated there was no evidence of stress cracking of Polycarbonate as a result of the test exposure.

Conforms

Page 23: TEST RESULTS - Home - Rainbow Technology

Rainbow Technology Telco and Power - Wasp and Ant Spray

Telcordia Technology, Inc Confidential – Restricted Access

See confidential restrictions on title page

19

DA-2043, Volume 1 Issue 1

October 2013

1.8 Packaged Aerosol Tests – Chemical /Stress Cracking of Modified-PPO Resins (Section 5.4C of TR-620)

C. Stress Cracking in Modified-PPO Resins. Use the procedure outlined in Section 5.4B except that polycarbonate is replaced with a Modified-PPO Resin.

Results: Review of the data provided by Dallas Laboratories, indicated there was no evidence of stress cracking of Modified PPO Resins as a result of the test exposure.

Conforms

1.9 Packaged Aerosol Tests – Chemical /Stress Cracking of ABS (Section 5.4D of TR-620)

D. Stress Cracking of ABS. Use the procedure outlined in Section 5.4B except that polycarbonate is replaced with ABS.

Results: Review of the data provided by Dallas Laboratories, indicated there was no evidence of stress cracking of ABS as a result of the test exposure.

Conforms

1.10 Packaged Aerosol Tests – Corrosion of Copper – Copper Mirror (Section 5.4E of TR-620)

E. Corrosion of Copper – Copper Mirror Test.

1. Outlined Method

A thin copper film is exposed under controlled conditions to a liquid wasp and hornet spray product. The effect on the copper film is noted after a specified exposure period.

Page 24: TEST RESULTS - Home - Rainbow Technology

Rainbow Technology Telco and Power - Wasp and Ant Spray

Telcordia Technology, Inc Confidential – Restricted Access

See confidential restrictions on title page

20

DA-2043, Volume 1 Issue 1

October 2013

2. Copper Mirror

A copper mirror consists of a vacuum-deposited film of copper metal (having a thickness equivalent to 10 +/- 5 percent transmission or normal incident light of 5000 angstroms) on a plane sheet of clear, transparent, polish glass. A convenient size is 2.54- cm by 7.6-cm (1- by 3-inch). These mirrors may be obtained from Evaporated Metal Films Corporations, Ithaca, N.Y. It is recommended that these mirrors be purchased in plastic tubes (2 mirrors per tube) which have been flushed with nitrogen. Fir ling term storage, place the plastic containers in a convenient size desiccator which has been flushed with nitrogen.

3. Method

Place two separate drops of the wasp and hornet spray to be tested (approximately 0.5 ml/drop) on the coated surface of the copper mirror. The dropd shall not be allowed to merge with one another. Store in a horizontal position, copper face up, in a clean environment at 24°C and 50 percent relative humidity for 24 hours. If an controlled air-conditioned environment is not available, a saturated solution of calcium nitrate per ASTM E-104 will provide 51 percent relative humidity. Gently remove the test material with alcohol taking care not to wipe or otherwise disturb the copper surface by mechanical abrasion. Examine visually against a white background using a standard light source per ASTM D1729. Any complete remove of the copper film, as evidence by the white background showing through, shall be cause for rejection. Discoloration of the copper due to a superficial reaction or to only a partial reduction of the thickness of the copper film shall not be cause for rejection.

Results: Review of the data provided by Dallas Laboratories, indicated there was no evidence of removal of copper film noted after a specified exposure period.

Conforms

Page 25: TEST RESULTS - Home - Rainbow Technology

Rainbow Technology Telco and Power - Wasp and Ant Spray

Telcordia Technology, Inc Confidential – Restricted Access

See confidential restrictions on title page

21

DA-2043, Volume 1 Issue 1

October 2013

Figure 1: Samples with Polyethylene in a 3 point test fixture

Page 26: TEST RESULTS - Home - Rainbow Technology

Rainbow Technology Telco and Power - Wasp and Ant Spray

Telcordia Technology, Inc Confidential – Restricted Access

See confidential restrictions on title page

22

DA-2043, Volume 1 Issue 1

October 2013

Figure 2: Samples with ABS, Polycarbonate and Modified PPO Test Bars in a 3 point test fixture

Page 27: TEST RESULTS - Home - Rainbow Technology

Rainbow Technology Telco and Power - Wasp and Ant Spray

Telcordia Technology, Inc Confidential – Restricted Access

See confidential restrictions on title page

23

DA-2043, Volume 1 Issue 1

October 2013

Figure 3: Sprayed samples with ABS Test Bars in a 3 point test fixture after exposure

Page 28: TEST RESULTS - Home - Rainbow Technology

Rainbow Technology Telco and Power - Wasp and Ant Spray

Telcordia Technology, Inc Confidential – Restricted Access

See confidential restrictions on title page

24

DA-2043, Volume 1 Issue 1

October 2013

Figure 4: Sprayed samples with Polycarbonate Test Bars in a 3 point test fixture after exposure

Page 29: TEST RESULTS - Home - Rainbow Technology

Rainbow Technology Telco and Power - Wasp and Ant Spray

Telcordia Technology, Inc Confidential – Restricted Access

See confidential restrictions on title page

25

DA-2043, Volume 1 Issue 1

October 2013

Figure 5: Sprayed samples with Modified PPO Test Bars in a 3 point test fixture after exposure

Page 30: TEST RESULTS - Home - Rainbow Technology

Rainbow Technology Telco and Power - Wasp and Ant Spray

Telcordia Technology, Inc Confidential – Restricted Access

See confidential restrictions on title page

26

DA-2043, Volume 1 Issue 1

October 2013

Figure 6: Dallas Laboratories Test Report October 20, 2013

Page 31: TEST RESULTS - Home - Rainbow Technology

Rainbow Technology Telco and Power - Wasp and Ant Spray

Telcordia Technology, Inc Confidential – Restricted Access

See confidential restrictions on title page

27

DA-2043, Volume 1 Issue 1

October 2013

Figure 7: Dallas Laboratories Test Report April 17, 2012

Page 32: TEST RESULTS - Home - Rainbow Technology
Page 33: TEST RESULTS - Home - Rainbow Technology

261 Cahaba Valley Parkway - Pelham, AL 35124-1146Tel: 1.800.637.6047 / 205.733.0333

Fax: 1.800.521.6896 / 205.733.8930www.rainbowtech.net

Woman-Owned Business Enterprise - Founded 1971

Safety Data Sheet (SDS)Safety Data Sheet Telco & Power Wasp & Ant Spray w/ ETOC

PAGE 1 of 4

SECTION I - IDENTIFICATION

PRODUCT NAME: Telco & Power Wasp & Ant w/ ETOC PRODUCT CODE: 173271000 PRODUCT USE: Insecticide COMPANY NAME: Rainbow Technology Corporation COMPANY ADDRESS: 261 Cahaba Valley Parkway, Pelham, Alabama 35124 COMPANY PHONE: 800-637-6047 EMERGENCY PHONE: 800-255-3924

SECTION II – HAZARDS IDENTIFICATION

CLASSIFICATION: Compressed Gas Eye Irritant: Category 2b Aspiration Hazard: Category 1 HAZARD STATEMENT(S): DANGER: Contains gas under pressure; May explode if heated. Causes eye irritation. May be fatal if

swallowed and enters airways. This product contains the following percentage of chemicals of unknown toxicity: 0% PRECAUTIONARY STATEMENTS: Keep away from heat, sparks, open flames, and hot surfaces. -No smoking. Pressurized

container: Do not pierce or burn, even after use. Protect from sunlight. Do not expose to temperatures exceeding 50C/122F. Store in a well-ventilated place. Wash hands thoroughly after handling. If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical attention. If swallowed: Immediately call a poison center or doctor. Do NOT induce vomiting. Store locked up. Dispose of contents and container in accordance with local, state, and national regulations.

SYMBOL: HAZARDS NOT OTHERWISE CLASSIFIED: N/A

SECTION III – COMPOSITION/INFORMATION ON INGREDIENTS

HAZARDOUS INGREDIENT CAS NUMBER PERCENT Isoparaffinic Hydrocarbon 64742-47-8 60-100% Carbon Dioxide 124-38-9 1-5%

SECTION IV - FIRST AID MEASURES

EYES: If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical advice or attention.

INGESTION: If swallowed: Immediately call a poison center or doctor. Do NOT induce vomiting. INHALATION: If inhaled: Remove person to fresh air and keep comfortable for breathing. Call a poison center or doctor if you feel

unwell. SKIN: Immediately wash with soap and water for 15 minutes. Remove contaminated clothing and shoes immediately. Seek medical

attention if irritation develops. ACUTE HEALTH HAZARDS: Eyes: redness, tearing, blurred vision CHRONIC HEALTH HAZARDS: Concentrating vapors and inhaling material can lead to oxygen deprivation, loss of brain function and

potential loss of life. NOTE TO PHYSICIAN: There is no specific treatment regimen. Treatment of overexposure should be directed at the control of

symptoms and the clinical condition of the patient.

SECTION V – FIRE-FIGHTING MEASURES

EXTINGUISHING MEDIA: Dry chemical, alcohol or alcohol-resistant foam or carbon dioxide. Water may be ineffective UNSUITABLE EXTINGUISHING MEDIA: Water spray/stream.

Revised Date: September 9, 2015Preparation Date: August 13, 2015

Product Name Rainbow Telco & Power Wasp & Ant Spray with ETOC®

Product Number 88500EPA Reg. No. 13283-31Manufacturer/Supplier Rainbow Technology Corporation

261 Cahaba Valley Parkway, Pelham, AL 35124 800.637.6047 www.rainbowtech.net

Contact Person Larry Joe Steeley, Jr.Emergency Information CHEMTEL 1-800-255-3924 813-248-0585 if located outside the U.S.

Safety Data Sheet Telco & Power Wasp & Ant Spray w/ ETOC

PAGE 1 of 4

SECTION I - IDENTIFICATION

PRODUCT NAME: Telco & Power Wasp & Ant w/ ETOC PRODUCT CODE: 173271000 PRODUCT USE: Insecticide COMPANY NAME: Rainbow Technology Corporation COMPANY ADDRESS: 261 Cahaba Valley Parkway, Pelham, Alabama 35124 COMPANY PHONE: 800-637-6047 EMERGENCY PHONE: 800-255-3924

SECTION II – HAZARDS IDENTIFICATION

CLASSIFICATION: Compressed Gas Eye Irritant: Category 2b Aspiration Hazard: Category 1 HAZARD STATEMENT(S): DANGER: Contains gas under pressure; May explode if heated. Causes eye irritation. May be fatal if

swallowed and enters airways. This product contains the following percentage of chemicals of unknown toxicity: 0% PRECAUTIONARY STATEMENTS: Keep away from heat, sparks, open flames, and hot surfaces. -No smoking. Pressurized

container: Do not pierce or burn, even after use. Protect from sunlight. Do not expose to temperatures exceeding 50C/122F. Store in a well-ventilated place. Wash hands thoroughly after handling. If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical attention. If swallowed: Immediately call a poison center or doctor. Do NOT induce vomiting. Store locked up. Dispose of contents and container in accordance with local, state, and national regulations.

SYMBOL: HAZARDS NOT OTHERWISE CLASSIFIED: N/A

SECTION III – COMPOSITION/INFORMATION ON INGREDIENTS

HAZARDOUS INGREDIENT CAS NUMBER PERCENT Isoparaffinic Hydrocarbon 64742-47-8 60-100% Carbon Dioxide 124-38-9 1-5%

SECTION IV - FIRST AID MEASURES

EYES: If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical advice or attention.

INGESTION: If swallowed: Immediately call a poison center or doctor. Do NOT induce vomiting. INHALATION: If inhaled: Remove person to fresh air and keep comfortable for breathing. Call a poison center or doctor if you feel

unwell. SKIN: Immediately wash with soap and water for 15 minutes. Remove contaminated clothing and shoes immediately. Seek medical

attention if irritation develops. ACUTE HEALTH HAZARDS: Eyes: redness, tearing, blurred vision CHRONIC HEALTH HAZARDS: Concentrating vapors and inhaling material can lead to oxygen deprivation, loss of brain function and

potential loss of life. NOTE TO PHYSICIAN: There is no specific treatment regimen. Treatment of overexposure should be directed at the control of

symptoms and the clinical condition of the patient.

SECTION V – FIRE-FIGHTING MEASURES

EXTINGUISHING MEDIA: Dry chemical, alcohol or alcohol-resistant foam or carbon dioxide. Water may be ineffective UNSUITABLE EXTINGUISHING MEDIA: Water spray/stream.

Page 34: TEST RESULTS - Home - Rainbow Technology

Safety Data Sheet (SDS)Safety Data Sheet Telco & Power Wasp & Ant Spray w/ ETOC

PAGE 2 of 4

SPECIAL FIRE FIGHTING PROCEDURES: Wear NIOSH approved Self Contained Breathing Apparatus with a full face piece operated in a positive pressure demand mode with full body protective clothing when fighting fires. Use water spray only to cool exposed containers.

UNUSUAL FIRE AND EXPLOSION HAZARDS: Keep away from sparks, open flames, and hot surfaces. No smoking. Do not spray on an open flame or other ignition source.

HAZARDOUS COMBUSTION PRODUCTS: Oxides of carbon

SECTION VI – ACCIDENTAL RELEASE MEASURES

PERSONAL PROTECTIVE EQUIPMENT: Refer to section VIII for proper Personal Protective Equipment. SPILL: Clean up with non-combustible material like vermiculite, sand or earth. If many cans are opened remove ignition sources. Prevent

spill from entering sewers, storm drains, and natural waterways.WASTE DISPOSAL: Dispose of in accordance with federal, state, and local regulations. Containers may be hazardous when empty.RCRA STATUS: Waste likely considered Non-hazardous under RCRA, however product should be fully characterized prior to disposal

(40 CFR 261).

SECTION VII – HANDLING AND STORAGE

HANDLING AND STORAGE: Protect from sunlight. Store in a well ventilated place. Do not expose to temperatures exceeding 50°C/122°F. Pressurized container: Do not pierce or burn, even after use. Store locked up.

OTHER PRECAUTIONS: Keep out of the reach of children.INCOMPATIBILITY: Some Plastics and strong oxidizers

SECTION VIII – EXPOSURE CONTROLS/PERSONAL PROTECTION

HAZARDOUS INGREDIENT OSHA PEL ACGIH TLVIsoparaffinic Hydrocarbon 400 ppm 400 ppmCarbon Dioxide 5000 ppm 5000 ppm

ENGINEERING CONTROLS / VENTILATION: General ventilation adequate.RESPIRATORY PROTECTION: Not required with normal use.PERSONAL PROTECTIVE EQUIPMENT: Wear eye protection.ADDITIONAL MEASURES: Wash hands thoroughly after handling.

SECTION IX - PHYSICAL AND CHEMICAL PROPERTIES

APPEARANCE: Clear AerosolODOR: Mild odor ODOR THRESHOLD: N/DBOILING POINT: 450°F FREEZING POINT: N/DFLAMMABILITY: Not considered a flammable aerosol or an extremely flammable aerosol by OSHA (29CFR 1910.1200)FLASH POINT: > 200°F (93°C) AUTOIGNITION TEMPERATURE: N/DLOWER FLAMMABILITY LIMIT: N/AUPPER FLAMMABILITY LIMIT: N/AVAPOR PRESSURE (mm Hg): 90-100 psiVAPOR DENSITY (AIR=1): <6EVAPORATION RATE: < 1SPECIFIC GRAVITY (H2O=1): 0.81pH: N/ASOLIDS (%): N/DSOLUBILITY IN WATER: 0%PARTITION COEFFICIENT: n-OCTANOL/WATER (KOW): N/DVOLATILITY INCLUDING WATER (%): 3%VOLATILE ORGANIC COMPOUNDS (VOC): <1%DIELECTRIC STRENGTH (Volts): 48,100DECOMPOSITION TEMPERATURE: N/D

Product No. 88500 Date of Revision: September 9, 2015 Page 2 of 4

Page 35: TEST RESULTS - Home - Rainbow Technology

Safety Data Sheet (SDS)Safety Data Sheet Telco & Power Wasp & Ant Spray w/ ETOC

PAGE 3 of 4

VISCOSITY: N/D

SECTION X – STABILITY AND REACTIVITY DATA

REACTIVITY: None Known CHEMICAL STABILITY: Stable CONDITIONS TO AVOID: Temperatures greater than 122°F and sources of ignition. INCOMPATIBILITY: Some Plastics and strong oxidizers HAZARDOUS DECOMPOSITION OR BY-PRODUCT: Oxides of carbon POSSIBLE HAZARDOUS REACTIONS: None Known

SECTION XI – TOXICOLOGICAL INFORMATION

TOXICOLOGICAL INFORMATION: Isoparaffinic Hydrocarbon (64742-47-8) Eye Damage/Irritation: 2B; Aspriration Hazard: Category 1

ROUTES OF ENTRY: Ingestion, Inhalation, Skin EYES: Causes irritation, redness, tearing. INGESTION: may causes nausea, diarrhea, vomiting INHALATION: May cause dizziness. Excessive exposure may lead to oxygen deprivation and unconsciousness. SKIN: May cause mild irritation, localized defatting. MEDICAL CONDITION AGGRAVATED: Excessive exposure will aggravate respiratroy cardiovascular or pulmonary illnesses. ACUTE HEALTH HAZARDS: Eyes: redness, tearing, blurred vision CHRONIC HEALTH HAZARDS: Concentrating vapors and inhaling material can lead to oxygen deprivation, loss of brain function and

potential loss of life. CARCINOGENICITY: OSHA: No ACGIH: No NTP: No IARC: No OTHER: N/A

SECTION XII – ECOLOGICAL INFORMATION

ECOLOGICAL INFORMATION: This product is extremely toxic to aquatic organisms, including fish and invertebrates. Do not apply directly to water, to areas where surface water is present or to intertidal areas below the mean water mark. Do not apply when weather conditions favor drift from treated areas. Drift and runoff from treated areas may be hazardous to aquatic organisms in neighboring areas. Do not contaminate water when disposing of equipment washwaters.

BIODEGRADABILITY: Component or components of this product are not biodegradable. BIOACCUMULATION: Components in this mixture can bioaccumulate in aquatic organisms. SOIL MOBILITY: This product is mobile in soil. OTHER ECOLOGICAL HAZARDS: This material is toxic to aquatic life.

SECTION XIII – DISPOSAL CONSIDERATIONS

WASTE DISPOSAL: Dispose of in accordance with federal, state, and local regulations. Containers may be hazardous when empty. RCRA STATUS: Waste likely considered Non-hazardous under RCRA, however product should be fully characterized prior to disposal

(40 CFR 261).

SECTION XIV - TRANSPORTATION INFORMATION

PROPER SHIPPING NAME: Aerosols, Ltd. Qty. HAZARD CLASS/DIVISION: 2.2 UN/NA NUMBER: UN 1950 PACKAGING GROUP: N/A AIR SHIPMENT PROPER SHIPPING NAME: Aerosols, Ltd. Qty. HAZARD CLASS/DIVISION: 2.2 UN/NA NUMBER: UN 1950 SHIPPING BY WATER: VESSEL (IMO/IMDG) PROPER SHIPPING NAME: Aerosols, Ltd. Qty.

Product No. 88500 Date of Revision: September 9, 2015 Page 3 of 4

Page 36: TEST RESULTS - Home - Rainbow Technology

Safety Data Sheet (SDS)Safety Data Sheet Telco & Power Wasp & Ant Spray w/ ETOC

PAGE 4 of 4

HAZARD CLASS/DIVISION: 2.2 UN/NA NUMBER: UN 1950 ENVIRONMENTAL HAZARDS WATER: Marine Pollutant

SECTION XV - REGULATORY INFORMATION

TSCA STATUS: All Chemicals are listed or exempt. CERCLA (COMPREHENSIVE RESPONSE COMPENSATION, AND LIABILITY ACT): None SARA 311/312 HAZARD CATEGORIES: None SARA 313 REPORTABLE INGREDIENTS: None STATE REGULATIONS: California Proposition 65: None INTERNATIONAL REGULATIONS: All components are listed or exempted. This chemical is a pesticide product registered by the Environmental Protection Agency and is subject to certain labeling requirements under federal pesticide law. These requirements differ from the classification crieteria and hazard information required for safety data sheets, and for workplace labels of non-pesticide chemicals. Following is the hazard information as required on the pesticide label: CAUTION: Harmful if swallowed or absorbed through skin. Avoid contact with eyes, skin, or clothing. Thoroughly wash with soap and water after handling and before eating, drinking, chewing gum, using tobacco, or using the toilet. Remove and wash contaminated clothing before reuse. Prolonged or frequently repeated contact may cause allergic reactions in some individuals. Flammable. Contents under pressure. Keep away from heat, sparks and open flame. Do not puncture or incinerate container. Exposure to temperatures above 130°F may cause bursting. EPA Reg. No. 13283-31 EPA Est. 44446-TX-1 NFPA HEALTH: 2 HMIS HEALTH: 2 NFPA FLAMMABILITY: 1 HMIS FLAMMABILITY: 1 NFPA REACTIVITY: 1 HMIS REACTIVITY: 1 NFPA OTHER: None HMIS PROTECTION: A

SECTION XVI - ADDTIONAL INFORMATION

PREPARATION BY: Jonathon Jarvis DATE PREPARED: 08/13/2015 REVISION DATE: 08/13/2015 N/A = Not Applicable; N/D = Not Determined DISCLAIMER: To the best of our knowledge, information contained herein is accurate. However there is no assumption of liability for the accuracy or completeness of the information contained herein. Final determination of suitability of any material is the sole responsibility of the user. All materials may present unknown hazards and should be used with caution. Although certain hazards are described herein, we cannot guarantee that these are the only hazard which exists. The information contained in this SDS was obtained from current and reliable sources; however, the data is provided without any warranty, expressed or implied, regarding its correctness or accuracy. Since the conditions or handling, storage and disposal of this product are beyond the control of the manufacturer, the manufacturer will not be responsible for loss, injury, or expense arising out of the products improper use. No warranty, expressed or inferred, regarding the product described in this SDS shall be created or inferred by any statement in this SDS. Various government agencies may have specific regulations regarding the transportation, handling, storage, use, or disposal of this product which may not be covered by this SDS. The user is responsible for full compliance.

Safety Data Sheet Telco & Power Wasp & Ant Spray w/ ETOC

PAGE 4 of 4

HAZARD CLASS/DIVISION: 2.2 UN/NA NUMBER: UN 1950 ENVIRONMENTAL HAZARDS WATER: Marine Pollutant

SECTION XV - REGULATORY INFORMATION

TSCA STATUS: All Chemicals are listed or exempt. CERCLA (COMPREHENSIVE RESPONSE COMPENSATION, AND LIABILITY ACT): None SARA 311/312 HAZARD CATEGORIES: None SARA 313 REPORTABLE INGREDIENTS: None STATE REGULATIONS: California Proposition 65: None INTERNATIONAL REGULATIONS: All components are listed or exempted. This chemical is a pesticide product registered by the Environmental Protection Agency and is subject to certain labeling requirements under federal pesticide law. These requirements differ from the classification crieteria and hazard information required for safety data sheets, and for workplace labels of non-pesticide chemicals. Following is the hazard information as required on the pesticide label: CAUTION: Harmful if swallowed or absorbed through skin. Avoid contact with eyes, skin, or clothing. Thoroughly wash with soap and water after handling and before eating, drinking, chewing gum, using tobacco, or using the toilet. Remove and wash contaminated clothing before reuse. Prolonged or frequently repeated contact may cause allergic reactions in some individuals. Flammable. Contents under pressure. Keep away from heat, sparks and open flame. Do not puncture or incinerate container. Exposure to temperatures above 130°F may cause bursting. EPA Reg. No. 13283-31 EPA Est. 44446-TX-1 NFPA HEALTH: 2 HMIS HEALTH: 2 NFPA FLAMMABILITY: 1 HMIS FLAMMABILITY: 1 NFPA REACTIVITY: 1 HMIS REACTIVITY: 1 NFPA OTHER: None HMIS PROTECTION: A

SECTION XVI - ADDTIONAL INFORMATION

PREPARATION BY: Jonathon Jarvis DATE PREPARED: 08/13/2015 REVISION DATE: 08/13/2015 N/A = Not Applicable; N/D = Not Determined DISCLAIMER: To the best of our knowledge, information contained herein is accurate. However there is no assumption of liability for the accuracy or completeness of the information contained herein. Final determination of suitability of any material is the sole responsibility of the user. All materials may present unknown hazards and should be used with caution. Although certain hazards are described herein, we cannot guarantee that these are the only hazard which exists. The information contained in this SDS was obtained from current and reliable sources; however, the data is provided without any warranty, expressed or implied, regarding its correctness or accuracy. Since the conditions or handling, storage and disposal of this product are beyond the control of the manufacturer, the manufacturer will not be responsible for loss, injury, or expense arising out of the products improper use. No warranty, expressed or inferred, regarding the product described in this SDS shall be created or inferred by any statement in this SDS. Various government agencies may have specific regulations regarding the transportation, handling, storage, use, or disposal of this product which may not be covered by this SDS. The user is responsible for full compliance.

Product No. 88500 Date of Revision: September 9, 2015 Page 4 of 4