TESTREPORT
ReportNo.:D6387.0130147
Renderedto:
CRLAURENCECO.,INC.
Vernon,California
PRODUCTTYPE:ArchitecturalTerraceDoor (InSwing)
SERIES/MODEL:900
SPECIFICATION: AAMA/WDMA/CSA101/I.S.2/A44008,NAFSNorthAmerican
FenestrationStandard/SpecificationforWindows,Doors,andSkylights.
Title SummaryofResults
PrimaryProductDesignator
ClassAW– PG40:SizeTested
1219x2438mm(48x96in.)
– TypeATD
DesignPressure ±1920 Pa(±40.10 psf)
AirInfiltration 0.5 L/s/m2 (0.10 cfm/ft2)
WaterPenetrationResistanceTestPressure 390 Pa(8.15 psf)
TestCompletionDate: 08/22/2014
ReferencemustbemadetoReportNo.D6387.0130147,dated02/12/15forcompletetest
specimendescriptionanddetailedtestresults.
������������ ��� ���� �����������
��� ������������������ �������������
��������� ����� ��� �������� �� ���� !"#�$�%
TestReportNo.:D6387.0130147
ReportDate:10/03/14
Revision1Date:02/12/15
TestRecordRetentionEndDate:08/22/18
Page1of8
1.0 ReportIssuedTo: CRLaurenceCo.,Inc.
2100East38thStreet
Vernon,California90058
2.0 TestLaboratory: ArchitecturalTesting,Inc.
4RanchoCircle
LakeForest,California92630
9494609600
3.0 ProjectSummary:
3.1 ProductType:ArchitecturalTerraceDoor(InSwing)
3.2 Series/Model:900
3.3 ComplianceStatement: Resultsobtainedaretestedvaluesandweresecuredby
using the designated test methods. The specimen tested successfully met the
performancerequirementsforaClassAW–PG40:SizeTested1219x2438mm
(48x96in.)–TypeATD rating.
3.4 TestDates:08/14/201408/22/2014
3.5 TestLocation: C.R.Laurence'stestfacilityinLosAngeles,California.Calibration
of test equipment was performed by Architectural Testing in accordance with
AAMA 20501 "InPlant Testing Guidelines for Manufacturers and Independent
Laboratories".
3.6 Test Sample Source: The test specimen was provided by the client.
Representative samples of the test specimen will be retained by Architectural
Testingforaminimumoffouryearsfromthetestcompletiondate.
3.7 Drawing Reference: The test specimen drawings have been reviewed by
ArchitecturalTestingandarerepresentativeofthetestspecimensreportedherein.
TestspecimenconstructionwasverifiedbyArchitecturalTestingperthedrawings
locatedinAppendixC.Anydeviationsaredocumentedhereinoronthedrawings.
3.8 ListofOfficialObservers:
Name Company
MarcoRamirez CRLaurenceCo.,Inc.
JarodS.Hardman ArchitecturalTesting,Inc.
TestReportNo.:D6387.0130147
ReportDate:10/03/14
Revision1Date:02/12/15
TestRecordRetentionEndDate:08/22/18
Page2of8
4.0 TestSpecifications:
AAMA/WDMA/CSA 101/I.S.2/A44008, NAFS North American Fenestration
Standard/SpecificationforWindows,Doors,andSkylights.
AAMA 91010, Voluntary "Life Cycle" Specifications and Test Methods for AW Class
ArchitecturalWindowsandDoors.
5.0 TestSpecimenDescription:
5.1 ProductSizes:
OverallArea:2.97 m²(32.0 ft2)
Width Height
millimeters inches millimeters inches
Overallsize 1219 48 2438 96
Leaf 1181 461/2 2368 931/4
5.2 FrameConstruction:
FrameMember Material Description
ThresholdThermallybroken
aluminumUnion ofDie#H61266andDie#HE454withthermalbreakDie#279300.
HeadThermallybroken
aluminumUnionofDie#H61266andDie#H61265withthermalbreakDie#279300.
JambsThermallybroken
aluminumUnionofDie#H61264andDie#H61263withthermalbreakDie#279300.
Joinery Type Detail
Allcorners Coped
Secured through jamb at each corner intoscrewbosswithtwo#12x1"Hexheadscrews,and thencorner joint is cappedwith2"x2"x41/2"cornercap1/32"thickissiliconesealedoverthecornerjoint.
TestReportNo.:D6387.0130147
ReportDate:10/03/14
Revision1Date:02/12/15
TestRecordRetentionEndDate:08/22/18
Page3of8
5.0 TestSpecimenDescription:(Continued)
5.3 Leaf Construction:
Leaf Member Material Description
Toprail,bottom
rail,stiles
Thermallybroken
aluminum
UnionofDie#H61273andDie#H61272with
thermalbreakDie#279300.
Joinery Type Detail
Allcorners Mitered
Securedatcornerswithaluminumcornerkey,
Die#H80000,thatissecuredtorailsandstiles
with three dimples in the aluminum to retain
thekey.
5.4 Weatherstripping:
Description Quantity Location
Hollow bulb gasket (see
attacheddrawing#USA2964)1row
Inserted into channel of frame full
perimeter.
Foam filled bulb gasket (see
attacheddrawing#USA1820)1row
Inserted in channel of leaf full
perimeter.
5.5 Glazing:
Glass
TypeSpacerType
Interior
Lite
Exterior
LiteGlazingMethod
1"IGAluminum
A1D1
1/4"clear
tempered
1/4"clear
tempered
Interior tape glazed with 3/8" x
1/8" tape and a cap bead at
exterior side and secured at
interior with glazing bead (See
attached Drawing #60939) and
rubberwedgegasket(seeattached
Drawing#USA1819B)
Location QuantityDaylightOpening
GlassBitemillimeters inches
Leaf 1 994x2180 391/8 x8513/16 1/2"
TestReportNo.:D6387.0130147
ReportDate:10/03/14
Revision1Date:02/12/15
TestRecordRetentionEndDate:08/22/18
Page4of8
5.0 TestSpecimenDescription:(Continued)
5.6 Drainage:
DrainageMethod Size Quantity Location
Weephole 13/4"x1/4" 1 Midspanofthresholdatexteriorface.
Weephole 3/4"x1/8" 21" from each end of glazing pocket of
bottomrailofleaf.
5.7 Hardware:
Description Quantity Location
Hoppe Athinai M156/216N
handleassembly1
Located36"fromsillandsecuredtolock
stile with three #10 x 21/2" Phillips
ovalheadscrews.
Handle/deadboltstrike 1
Located directly opposite handle
assemblyonlockjambandsecuredwith
three #10 x 1/2" Phillips flat head
screws(seeattachedDrawing#90040).
Hoppeactivetonguesystem 1
Onetonguelocated12"fromsillandthe
other tongue located 30" from head on
leaf lock stile, system was secured to
stile with #8 x 1" Phillips flat head
screws6"oncenterspacingoffulllength
ofstile.
Tonguestrike 2
Locateddirectlyoppositetongueonlock
jamb and securedwith two#10 x 1/2"
Phillips flat head screws (see attached
drawing#90042B).
Shootboltstrike 2
Located directly opposite shoot bolt in
cornerofheadandsillat lockjamband
securedtoheadandsillwithtwo#10x
1/2" Phillips flat head screws (see
attacheddrawing#90043C).
Butthinge 4
Located83/4"fromsilland261/4"on
center,securedto framejambwithfour
#1224 x 7/8" Phillips flat head screws
and to leaf stile with four #12 x 1"
Phillips pan head screws (see attached
drawing#90024B).
TestReportNo.:D6387.0130147
ReportDate:10/03/14
Revision1Date:02/12/15
TestRecordRetentionEndDate:08/22/18
Page5of8
5.0 TestSpecimenDescription:(Continued)
5.8 Reinforcement:
DrawingNumber Location Material
C1253Insertedintocornerjointsofleaf
assembly.Aluminum
5.9 ScreenConstruction:Noscreenwasutilized.
6.0 Installation:
ThespecimenwasinstalledintoaPinewoodbuck. Theroughopeningallowedfora
3/8"shimspace. Theexteriorandinteriorperimetersofthedoorframeweresealed
withstructuralsiliconesealant.
Location AnchorDescription AnchorLocation
Fullperimeter #12x2"Phillipsflatheadscrew6" from corners and 12" on
center
TestReportNo.:D6387.0130147
ReportDate:10/03/14
Revision1Date:02/12/15
TestRecordRetentionEndDate:08/22/18
Page6of8
7.0 Test Results: The temperature during testing was 29°C (84°F). The results are
tabulatedasfollows:
TitleofTest Results Allowed Note
OperatingForce,
Forcetolatchtestprocedure,
perAAMA101
Forcetolatch:
40.0 N(9.0 lbf) ReportOnly
Deadbolt:
4.5 N/m (1.0 lbs/in) ReportOnly
Forcefordeadbolt:
0 N(0.0 lbf) ReportOnly
Forceforsecondary:
40.0 N(9.0 lbf) ReportOnly
AirLeakage,
InfiltrationperASTME283
at300Pa(6.27 psf)
0.5 L/s/m2
(0.10 cfm/ft2)
0.5 L/s/m2
(0.10 cfm/ft2) max. 1
WaterPenetration,
perASTME547andASTME331
at390Pa(8.15 psf) Pass Noleakage
LifeCycleperAAMA910
DoorLeafCycling,
(Firsthalf)
perAAMA910
12,500cycles Pass Nodamage
LockingHardwareCycling,
(Firsthalf)
perAAMA910
2000cycles Pass Nodamage
MisuseTestingperAAMA910
DoorLeaf VerticalLoad
at890 N(200 lbf) Pass Nodamage
DoorLeafCornerBlock
at334 N(75 lbf) Pass Nodamage
LifeCycleperAAMA910
DoorLeafCycling,
(Secondhalf)
perAAMA910
12,500cycles Pass Nodamage
LockingHardwareCycling,
(Secondhalf)
perAAMA910
2000cycles Pass Nodamage
TestReportNo.:D6387.0130147
ReportDate:10/03/14
Revision1Date:02/12/15
TestRecordRetentionEndDate:08/22/18
Page7of8
7.0 TestResults:(Continued)
TitleofTest Results Allowed Note
OperatingForce,
Forcetolatchtestprocedure,
perAAMA101
Forcetolatch:
40.0 N(9.0 lbf) ReportOnly
Deadbolt:
4.5 N/m (1.0 lbs/in) ReportOnly
Forcefordeadbolt:
0N(0.0 lbf) ReportOnly
Forceforsecondary:
40.0 N(9.0 lbf) ReportOnly
UniformLoadDeflection,
perASTME330
takenattop rail
+1920 Pa(+40.10 psf)
1920 Pa(40.10 psf)
1.3 mm(0.05")
1.0 mm(0.04")
6.1mm(0.24")max.
6.1mm(0.24")max. 2,3
AirLeakage,
InfiltrationperASTME283
at300Pa(6.27 psf)
0.4L/s/m2
(0.08 cfm/ft2)
0.5 L/s/m2
(0.10 cfm/ft2)max. 1
WaterPenetration,
perASTME547andASTME331
at390 Pa(8.15 psf) Pass Noleakage
UniformLoadStructural,
perASTME330
takenattop rail
+2880 Pa(+60.15 psf)
2880 Pa(60.15 psf)
0.3 mm(0.01")
0.0mm(0.00")
2.3mm(0.09")max.
2.3mm(0.09")max. 2,3
ForcedEntryResistance,
per AAMA1304 Pass Noentry
Note 1: The tested specimen meets (or exceeds) the performance levels specified in
AAMA/WDMA/CSA101/I.S.2/A440forairleakageresistance.
Note2:Loadswereheldfor10seconds.
Note3:Tapeandfilmwereusedtosealagainstairleakageduringstructuraltesting.In
ouropinion,thetapeandfilmdidnotinfluencetheresultsofthetest.
GeneralNote:Thedoorwastestedinaccordancewiththeventinguseclassification.
TestReportNo.:D6387.0130147
ReportDate:10/03/14
Revision1Date:02/12/15
TestRecordRetentionEndDate:08/22/18
Page8of8
TheservicelifeofthisreportwillexpireonthestatedTestRecordRetentionEndDate,at
which timesuchmaterials asdrawings,datasheets, samplesof test specimens, copiesof
this report, and any other pertinent project documentation, shall be discarded without
notice.
If test specimen contains glazing, no conclusions of any kind regarding the adequacy or
inadequacyof theglass inanyglazed test specimens canbemade. This reportdoesnot
constitutecertificationofthisproductnoranopinionorendorsementbythislaboratory.It
is theexclusivepropertyof theclientsonamedhereinandrelatesonlyto thespecimens
tested.Thisreportmaynotbereproduced,exceptinfull,withoutthewrittenapprovalof
ArchitecturalTesting,Inc.
ForARCHITECTURALTESTING,Inc.
___________________________________________ ________________________________________________
JarodS.Hardman KennyC.White
LaboratoryManager LaboratoryManager
JSH:ss
Attachments(pages):Thisreportiscompleteonlywhenallattachmentslistedareincluded.
AppendixA:AlterationAddendum(1)
AppendixB:Photographs(2)
AppendixC:Drawings(27)
ThisreportproducedfromcontrolleddocumenttemplateATI00506 issued04/25/11.
TestReportNo.:D6387.0130147
ReportDate:10/03/14
Revision1Date:02/12/15
TestRecordRetentionEndDate:08/22/18
RevisionLog
Rev.# Date Page(s) Revision(s)
0 10/03/14 N/A Originalreportissue.
1 02/12/15 Cover,1 CorrectedPG80toPG40toreflect
resultslistedinperformanceof
product.
TestReportNo.:D6387.0130147
ReportDate:10/03/14
Revision1Date:02/12/15
TestRecordRetentionEndDate:08/22/18
AppendixA
AlterationAddendum
Alteration#1: Date–08/22/14
Causeforalteration–Waterpenetrationfailure
Remedial action taken – Weep hole flap cover was removed to allow
systemtodrainmoreefficiently.
TestReportNo.:D6387.0130147
ReportDate:10/03/14
Revision1Date:02/12/15
TestRecordRetentionEndDate:08/22/18
AppendixB
Photographs
TestReportNo.:D6387.0130147
ReportDate:10/03/14
Revision1Date:02/12/15
TestRecordRetentionEndDate:08/22/18
PhotoNo.1
DoorCyclingSetup–Interior
PhotoNo.2
DoorCyclingSetup–Exterior
TestReportNo.:D6387.0130147
ReportDate:10/03/14
Revision1Date:02/12/15
TestRecordRetentionEndDate:08/22/18
PhotoNo.3
DoorCycling–CompletionofFirstHalf
PhotoNo.4
DoorCycling–CompletionofSecondHalf
TestReportNo.:D6387.0130147
ReportDate:10/03/14
Revision1Date:02/12/15
TestRecordRetentionEndDate:08/22/18
AppendixC
Drawings