Test Report No. : 11989461S · Country of Mass-production : Japan Condition of EUT : Engineering...
Transcript of Test Report No. : 11989461S · Country of Mass-production : Japan Condition of EUT : Engineering...
Test report No. : 11989461S Page : 1 of 28 Issued date : November 28, 2017
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401 13-EM-F0429
RADIO TEST REPORT
Test Report No. : 11989461S
Applicant : TAIYO YUDEN CO., LTD. Type of Equipment : Bluetooth Smart / ANT Module Model No. : EYSLCN Test standard : EN 300 328 V2.1.1 Test item : Antenna Terminal Conducted Tests Test Result : Complied
1. This test report shall not be reproduced in full or partial, without the written approval of
UL Japan, Inc. 2. The results in this report apply only to the sample tested. 3. This sample tested is in compliance with the above standard(s). 4. The test results in this report are traceable to the national or international standards. 5. The opinions and the interpretations to the result of the description in this report are outside scopes
where UL Japan has been accredited. 6. This test report covers Radio technical requirements. It does not cover administrative issues such as
Manual or non-Radio test related Requirements. (if applicable)
Date of test: October 20 to 25, 2017 Representative test engineer:
Hiroyuki Morikawa
Engineer Consumer Technology Division
Approved by :
Toyokazu Imamura Leader
Consumer Technology Division
RTL02610 The testing in which "Non-accreditation" is displayed is outside the accreditation scopes in UL Japan.
There is no testing item of "Non-accreditation".
Test report No. : 11989461S Page : 2 of 28 Issued date : November 28, 2017
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
REVISION HISTORY
Original Test Report No.: 11989461S
Revision Test report No. Date Page revised Contents - (Original) 11989461S November 28,
2017 - -
Test report No. : 11989461S Page : 3 of 28 Issued date : November 28, 2017
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
CONTENTS PAGE
SECTION 1: Customer information ................................................................................... 4
SECTION 2: Equipment under test (E.U.T.) ..................................................................... 4
SECTION 3: Test specification, procedures & results ...................................................... 5
SECTION 4: Operation of E.U.T. during testing ............................................................... 8
SECTION 5: Antenna Terminal Conducted Tests .......................................................... 11
APPENDIX 1: Test data ........................................................................................................ 12
RF Output Power ........................................................................................................................ 12 Power Spectral Density ............................................................................................................... 14 Occupied Channel Bandwidth .................................................................................................... 19 Transmitter unwanted emissions in the out-of-band domain ...................................................... 23 Receiver Blocking ....................................................................................................................... 24
APPENDIX 2: Test instruments ........................................................................................... 26
APPENDIX 3: Photographs of test setup ............................................................................. 27
Antenna terminal conducted tests other than Receiver Blocking ............................................... 27 Receiver Blocking ....................................................................................................................... 28
Test report No. : 11989461S Page : 4 of 28 Issued date : November 28, 2017
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
SECTION 1: Customer information
Company Name : TAIYO YUDEN CO., LTD. Address : 8-1, Sakae-cho, Takasaki-shi, Gunma, 370-8522 Japan Telephone Number : +81-27-324-2300 Facsimile Number : +81-27-324-2301 Contact Person : Hideki Kato
SECTION 2: Equipment under test (E.U.T.)
2.1 Identification of E.U.T.
Type of Equipment : Bluetooth Smart / ANT Module Model No. : EYSLCN Serial No. : Refer to Clause 4.2 Rating : DC 3 V (DC 1.7 V to DC 3.6 V) Receipt Date of Sample : October 11, 2017 Country of Mass-production : Japan Condition of EUT : Engineering prototype
(Not for Sale: This sample is equivalent to mass-produced items.) Modification of EUT : No Modification by the test lab.
2.2 Product Description
Model: EYSLCN (referred to as the EUT in this report) is a Bluetooth Smart / ANT Module. General Specification Clock frequency(ies) in the system : 32.768 kHz, 32 MHz Radio Specification
* Receiver category: 2
< Bluetooth (BT) Low Energy (LE) (1 Mbps, 2 Mbps) > Radio Type : Transceiver Frequency of Operation : 2402 MHz - 2480 MHz Modulation : GFSK Power Supply (radio part input) : DC 1.3 V Antenna type : Monopole Antenna Gain : +0.9 dBi Operating Temperature : -40 deg. C to +105 deg. C
< ANT (1 Mbps) > Radio Type : Transceiver Frequency of Operation : 2402 MHz - 2480 MHz Modulation : GFSK Power Supply (radio part input) : DC 1.3 V Antenna type : Monopole Antenna Gain : +0.9 dBi Operating Temperature : -40 deg. C to +105 deg. C < Nordic Original (2 Mbps) > Radio Type : Transceiver Frequency of Operation : 2402 MHz - 2480 MHz Modulation : GFSK Power Supply (radio part input) : DC 1.3 V Antenna type : Monopole Antenna Gain : +0.9 dBi Operating Temperature : -40 deg. C to +105 deg. C
Test report No. : 11989461S Page : 5 of 28 Issued date : November 28, 2017
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
SECTION 3: Test specification, procedures & results 3.1 Test Specification Radio : EN 300 328 V2.1.1 Title : Wideband transmission systems; Data transmission equipment operating in the 2.4GHz ISM
band and using wide band modulation techniques; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
Purpose of test : Compliance with the harmonized RE directive 2014/53/EU. 3.2 Procedures and results
No. Item Test
Procedure Limit Remarks
Worst margin
Exclusions Results
1 RF output power Clause 5.4.2 Clause 4.3.2.2 Conducted - N/A Complied
2 Power Spectral Density Clause 5.4.3 Clause 4.3.2.3 Conducted - N/A Complied
3 Duty cycle, Tx-sequence, Tx-gap Clause 5.4.2 Clause 4.3.2.4 Conducted - N/A N/A *1)
4 Medium Utilisation (MU) factor Clause 5.4.2 Clause 4.3.2.5 Conducted - N/A N/A *1)
5
Adaptivity (adaptive equipment using modulations other than FHSS)
Clause 5.4.6 Clause 4.3.2.6 Conducted - N/A N/A *2)
6 Occupied Channel Bandwidth Clause 5.4.7 Clause 4.3.2.7 Conducted - N/A Complied
7 Transmitter unwanted emissions in the out-of-band domain
Clause 5.4.8 Clause 4.3.2.8 Conducted - N/A Complied
8 Transmitter unwanted emissions in the spurious domain
Clause 5.4.9 Clause 4.3.2.9 Radiated N/A *4) N/A *4)
9 Receiver Spurious emissions
Clause 5.4.10 Clause 4.3.2.10 Radiated N/A *4) N/A *4)
10 Transmitter unwanted emissions in the spurious domain
Clause 5.4.9 Clause 4.3.2.9 Conducted N/A *4) N/A *4)
11 Receiver Spurious emissions
Clause 5.4.10 Clause 4.3.2.10 Conducted N/A *4) N/A *4)
12 Receiver Blocking Clause 5.4.11 Clause 4.3.2.11 Conducted - N/A Complied
13 Geo-location capability
- Clause 4.3.2.12 - - N/A N/A *3)
Note: UL Japan, Inc.’s EMI Work Procedure 13-EM-W0420. *1) The test is not applicable since the EUT is an adaptive equipment and does not operate in a non-adaptive mode. *2) The test is not applicable since the RF output power of the EUT is less than 10 dBm (e.i.r.p.). *3) The EUT does not have Geo-location capability. *4) The test has not been performed according to the customer’s request.
Test report No. : 11989461S Page : 6 of 28 Issued date : November 28, 2017
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
3.3 Additions or deviations to standards No addition, exclusion nor deviation has been made from the standard. 3.4 Uncertainty The following uncertainties have been calculated to provide a confidence level of 95 % using a coverage factor k = 2. Shonan EMC Lab.
Antenna terminal test Uncertainty (+/-)Power Measurement above 1 GHz (Average Detector)_SPM-06 0.72 dBPower Measurement above 1 GHz (Average Detector)_SPM-07 0.74 dBPower Measurement above 1 GHz (Average Detector)_SPM-08, 09, 10,11 1.27 dBConducted emissions Measurement (below 1 GHz) 1.6 dBConducted emissions Power Density Measurement (1 GHz-3 GHz) 1.3 dBConducted emissions Measurement (3 GHz-18 GHz) 2.2 dBConducted emissions Measurement (18 GHz-26.5 GHz) 2.3 dBFrequency Measurement 5.3 x 10^-6Bandwidth Measurement 1.01 %Duty cycle and Time Measurement 0.012 %Temperature 0.95 deg.C.Voltage 0.24 %Receiver Blocking (Wanted RF Level)_SWT-01 1.62 dBReceiver Blocking (Blocking Signal Level)_SWT-01 1.73 dBReceiver Blocking (Wanted RF Level)_SBTR01 1.73 dBReceiver Blocking (Blocking Signal Level)_SBTR01 1.73 dBReceiver Blocking (Blocking Signal Level)_without tester 1.71 dBHumidity 3.4 % Kashima EMC Lab.
Uncertainty (+/-)0.7 dB0.9 dB1.5 dB2.2 dB
5.3 x 10^-62.0%
0.012%
Calicurated dataUncertainty (+/-)
0.89 deg. C.4.6%
Calicurated dataUncertainty (+/-)
0.42%
Humidity
Power supply Voltage
Spurious emissions, Power density measurement (3G-18GHz)Frequency measurementBandwidth measurementDuty cycle and Time measurement
Temperature and Humidity Chamber
Antenna terminal testPower measurement above 1GHzSpurious emissions, Power density measurement (below 1GHz)Spurious emissions, Power density measurement (1G-3GHz)
Temperature
Test report No. : 11989461S Page : 7 of 28 Issued date : November 28, 2017
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
3.5 Test Location UL Japan, Inc. Shonan EMC Lab.1-22-3, Megumigaoka, Hiratsuka-shi, Kanagawa-ken 259-1220 JAPANTelephone: +81 463 50 6400, Facsimile: +81 463 50 6401JAB Accreditation No. RTL02610
Test siteIC RegistrationNumber
Width x Depth xHeight (m)
Size of reference ground plane (m) /horizontal conducting plane
Maximummeasurementdistance
No.1 Semi-anechoicchamber
2973D-1 20.6 x 11.3 x 7.65 20.6 x 11.3 10 m
No.2 Semi-anechoicchamber
2973D-2 20.6 x 11.3 x 7.65 20.6 x 11.3 10 m
No.3 Semi-anechoicchamber
2973D-3 12.7 x 7.7 x 5.35 12.7 x 7.7 5 m
No.4 Semi-anechoicchamber
- 8.1 x 5.1 x 3.55 8.1 x 5.1 -
No.1 Shielded room - 6.8 x 4.1 x 2.7 6.8 x 4.1 -No.2 Shielded room - 6.8 x 4.1 x 2.7 6.8 x 4.1 -No.3 Shielded room - 6.3 x 4.7 x 2.7 6.3 x 4.7 -No.4 Shielded room - 4.4 x 4.7 x 2.7 4.4 x 4.7 -No.5 Shielded room - 7.8 x 6.4 x 2.7 7.8 x 6.4 -No.6 Shielded room - 7.8 x 6.4 x 2.7 7.8 x 6.4 -No.8 shielded room - 3.45 x 5.5 x 2.4 3.45 x 5.5 -No.1 Measurementroom
- 2.55 x 4.1 x 2.5 - -
UL Japan, Inc. Kashima EMC Lab.1614 Mushihata, Katori-shi, Chiba-ken, 289-0341 JAPANTelephone: +81 478 88 6500, Facsimile: +81 478 82 3373JAB Accreditation No. : RTL02610
Test siteICRegistrationNumber
Width x Depth xHeight (m)
Size of referenceground plane (m) / horizontalconducting plane
Maximummeasurementdistance
No.1 Open site 4659A-1 6.0 x 5.5 x 2.5 20 x 40 10 m
No.2 Open site 4659A-2 4.4 x 4.4 x 2.15 18 x 20 10 m
No.5 Open site 4659A-5 8.6 x 7.1 x 2.4 18 x 23 10 m
No.1 Shielded room 4659A-1 5.4 x 4.5 x 2.3 - -
No.2 Shielded room 4659A-2 3.6 x 2.7 x 2.3 - -
No.3 Shielded room - 5.4 x 3.6 x 2.3 - -
No.4 Shielded Room - 6.1 x 6.1 x 3.1 - -
No.5 Shielded Room 4659A-5 4.2 x 3.1 x 2.5 - -
No.3 Fully Anechoic Chamber - 7.0 x 3.5 x 3.5 - -
No.6 Semi-anechoic Chamber 4659A-6 8.5 x 5.5 x 5.2 - 3 m
No.10 Semi-anechoic Chamber 4659A-10 18.4 x 9.9 x 7.7 - 10 m
No.11 Semi-anechoic Chamber 4659A-7 9.0 x 6.5 x 5.2 - 3 m
No.1 Measurement room - 5.0 x 3.7 x 2.6 - -
No.2 Measurement room - 4.3 x 4.4 x 2.7 - -
No.3 Measurement room - 4.3 x 4.4 x 2.7 - - 3.6 Test data, Test instruments, and Test set up Refer to APPENDIX.
Test report No. : 11989461S Page : 8 of 28 Issued date : November 28, 2017
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
SECTION 4: Operation of E.U.T. during testing 4.1 Operating Mode(s)
Mode Remarks* Bluetooth(BT) Low Energy (LE) 1 Mbps Maximum Packet Size, PRBS9 Bluetooth(BT) Low Energy (LE) 2 Mbps Maximum Packet Size, PRBS9 ANT 1 Mbps 1 Mbps Nordic Original 2 Mbps 2 Mbps *Power of the EUT was set by the software as follows;Power settings: +4 dBm Software: Radio_test_tool_BLE2M (for except receiver blocking test) Blocking_tool (for receiver blocking test) *This setting of software is the worst case. Any conditions under the normal use do not exceed the condition of setting. In addition, end users cannot change the settings of the output power of the product.
*The details of Operating mode(s)
Test Item Operating Mode Tested frequency RF output power, Power Spectral Density
Transmitting (Tx) BT LE 1 Mbps Transmitting (Tx) BT LE 2 Mbps
2402 MHz 2440 MHz 2480 MHz
Transmitting (Tx) ANT 1 Mbps Transmitting (Tx) Nordic Original 2 Mbps
2402 MHz 2441 MHz 2480 MHz
Occupied channel bandwidth, Transmitter unwanted emissions in the out-of-band domain
Transmitting (Tx) BT LE 1 Mbps Transmitting (Tx) BT LE 2 Mbps Transmitting (Tx) ANT 1 Mbps Transmitting (Tx) Nordic Original 2 Mbps
2402 MHz 2480 MHz
Receiver blocking
Communication, ANT 1 Mbps *1)
2402 MHz 2480 MHz
*1) Test mode was selected according to the test report: 11818213M-R1.
Extreme test condition Temperature -40 deg. C to +105 deg. C : operating temperature range of EUT Voltage Vnom: DC 3.0 V, Vmin: DC 1.7 V, Vmax: DC 3.6 V: operating voltage range of EUT
Test report No. : 11989461S Page : 9 of 28 Issued date : November 28, 2017
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
4.2 Configuration and peripherals Other than Receiver blocking test
Description of EUT and support equipment No. Item Model number Serial number Manufacturer Remarks
A Bluetooth Smart / ANT Module
EYSLCN 2 TAIYO YUDEN EUT
B Evaluation Board TE8648-2 - TAIYO YUDEN - C Laptop PC CF-T2 4CKSA46826 Panasonic - D AC Adaptor CF-AA1625A 1625AM406221913F FUJITSU -
List of cables used No. Name Length (m) Shield Remarks Cable Connector 1 USB Cable 2.0 Shielded Shielded - 2 DC Cable 0.5 + 2.0 Unshielded Unshielded - 3 DC Cable 1.2 Unshielded Unshielded - 4 AC Cable 0.8 Unshielded Unshielded -
C
1
GND
2
DC 3 V
A
AC 230 V / 50Hz
D
3 4
B
Test report No. : 11989461S Page : 10 of 28 Issued date : November 28, 2017
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
Receiver blocking test
Description of EUT and support equipment No. Item Model number Serial number Manufacturer Remarks
A Bluetooth Smart / ANT Module
EYSLCN 3 TAIYO YUDEN EUT
B PC CF-T2 4CKSA46826 Panasonic - C AC Adaptor CF-AA1625A 1625AM406Z21913F Panasonic - D Evaluation Board TE8648-2 - TAIYO YUDEN -
E Bluetooth Smart / ANT Module
EYSLCN 4 TAIYO YUDEN -
F Evaluation Board TE8648-2 - TAIYO YUDEN - List of cables used No. Name Length (m) Shield Remarks Cable Connector 1 USB Cable 1.2 Shielded Shielded - 2 DC Cable 0.5 + 2.0 Unshielded Unshielded - 3 DC Cable 1.1 Unshielded Unshielded - 4 AC Cable 0.8 Unshielded Unshielded - 5 USB Cable 1.8 + 3.0 Shielded Shielded - 6 DC Cable 0.5 + 2.0 Unshielded Unshielded -
B
1 2DC 3 V
AC 100 V / 50Hz
C
3 4
D
A
F
E
5 6DC 3 V
Test report No. : 11989461S Page : 11 of 28 Issued date : November 28, 2017
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
SECTION 5: Antenna Terminal Conducted Tests Test Procedure The tests were made with below setting connected to the antenna port.
Test Instrument used RemarkRF Output Power Power Meter Normal and Extreme conditionsPower Spectral Density Spectrum Analyzer Normal conditionOccupied Channel Bandwidth
Spectrum Analyzer Normal condition
Transmitter unwanted emissions in the out-of band domain
Spectrum Analyzer Normal conditions- Detector mode: RMS - Trace: Max Hold - Band power was used on behalf of the time domain power function. - Filter mode: Gaussian Filter Since the data in this test report has enough margin
Receiver Blocking Spectrum Analyzer Normal condition The test results are rounded off to two decimals place, so some differences might be observed. The equipment and cables were not used for factor 0.0 dB of the data sheets. Test data : APPENDIX Test result : Pass
Test report No. : 11989461S Page : 12 of 28 Issued date : November 28, 2017
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
APPENDIX 1: Test data
RF Output Power
Test place Shonan EMC Lab. No.5 Shielded Room Kashima EMC Lab. No.2 Measurement Room Report No. 11989461S (Shonan EMC Lab.) (Kashima EMC Lab.) Date October 20, 2017 October 25, 2017 Temperature / Humidity 24 deg. C / 51 % RH 22 deg. C / 53 % RH Engineer Kenichi Adachi Hiromitsu Tanabe Mode Tx
BTLE 1 Mbps Receiver Category : 2
Freq. P/M (AV) Cable Atten. Antenna Result Limit MarginTemp. Volt. Reading Loss Loss Gain
[MHz] [dBm] [dB] [dB] [dBi] [dBm] [dBm] [dB]2402.0 -7.17 1.58 9.80 0.90 5.11 20.00 14.892440.0 -7.19 1.59 9.80 0.90 5.10 20.00 14.902480.0 -7.28 1.60 9.80 0.90 5.02 20.00 14.982402.0 -5.64 0.95 10.04 0.90 6.25 20.00 13.752440.0 -5.61 0.95 10.04 0.90 6.28 20.00 13.722480.0 -5.63 0.95 10.04 0.90 6.26 20.00 13.742402.0 -5.72 0.95 10.04 0.90 6.17 20.00 13.832440.0 -5.69 0.95 10.04 0.90 6.20 20.00 13.802480.0 -5.70 0.95 10.04 0.90 6.19 20.00 13.812402.0 -8.44 0.95 10.04 0.90 3.45 20.00 16.552440.0 -8.54 0.95 10.04 0.90 3.35 20.00 16.652480.0 -8.68 0.95 10.04 0.90 3.21 20.00 16.792402.0 -8.40 0.95 10.04 0.90 3.49 20.00 16.512440.0 -8.49 0.95 10.04 0.90 3.40 20.00 16.602480.0 -8.62 0.95 10.04 0.90 3.27 20.00 16.73
Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss + Antenna Gain
Test Condition
max max
nom nom
min
max min
min max
min
BTLE 2 Mbps Receiver Category : 2Freq. P/M (AV) Cable Atten. Antenna Result Limit Margin
Temp. Volt. Reading Loss Loss Gain[MHz] [dBm] [dB] [dB] [dBi] [dBm] [dBm] [dB]2402.0 -7.18 1.58 9.80 0.90 5.10 20.00 14.902440.0 -7.19 1.59 9.80 0.90 5.10 20.00 14.902480.0 -7.28 1.60 9.80 0.90 5.02 20.00 14.982402.0 -5.64 0.95 10.04 0.90 6.25 20.00 13.752440.0 -5.62 0.95 10.04 0.90 6.27 20.00 13.732480.0 -5.63 0.95 10.04 0.90 6.26 20.00 13.742402.0 -5.72 0.95 10.04 0.90 6.17 20.00 13.832440.0 -5.70 0.95 10.04 0.90 6.19 20.00 13.812480.0 -5.72 0.95 10.04 0.90 6.17 20.00 13.832402.0 -8.45 0.95 10.04 0.90 3.44 20.00 16.562440.0 -8.54 0.95 10.04 0.90 3.35 20.00 16.652480.0 -8.68 0.95 10.04 0.90 3.21 20.00 16.792402.0 -8.39 0.95 10.04 0.90 3.50 20.00 16.502440.0 -8.49 0.95 10.04 0.90 3.40 20.00 16.602480.0 -8.61 0.95 10.04 0.90 3.28 20.00 16.72
Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss + Antenna Gain
min
Test Condition
max max
nom nom
min
max min
min max
Test report No. : 11989461S Page : 13 of 28 Issued date : November 28, 2017
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
RF Output Power
Test place Shonan EMC Lab. No.5 Shielded Room Kashima EMC Lab. No.2 Measurement Room Report No. 11989461S (Shonan EMC Lab.) (Kashima EMC Lab.) Date October 20, 2017 October 25, 2017 Temperature / Humidity 24 deg. C / 51 % RH 22 deg. C / 53 % RH Engineer Kenichi Adachi Mode Tx
ANT 1 Mbps Receiver Category : 2
Freq. P/M (AV) Cable Atten. Antenna Result Limit MarginTemp. Volt. Reading Loss Loss Gain
[MHz] [dBm] [dB] [dB] [dBi] [dBm] [dBm] [dB]2402.0 -7.17 1.58 9.80 0.90 5.11 20.00 14.892441.0 -7.18 1.59 9.80 0.90 5.11 20.00 14.892480.0 -7.28 1.60 9.80 0.90 5.02 20.00 14.982402.0 -5.64 0.95 10.04 0.90 6.25 20.00 13.752441.0 -5.61 0.95 10.04 0.90 6.28 20.00 13.722480.0 -5.62 0.95 10.04 0.90 6.27 20.00 13.732402.0 -5.71 0.95 10.04 0.90 6.18 20.00 13.822441.0 -5.69 0.95 10.04 0.90 6.20 20.00 13.802480.0 -5.71 0.95 10.04 0.90 6.18 20.00 13.822402.0 -8.44 0.95 10.04 0.90 3.45 20.00 16.552441.0 -8.55 0.95 10.04 0.90 3.34 20.00 16.662480.0 -8.68 0.95 10.04 0.90 3.21 20.00 16.792402.0 -8.39 0.95 10.04 0.90 3.50 20.00 16.502441.0 -8.49 0.95 10.04 0.90 3.40 20.00 16.602480.0 -8.62 0.95 10.04 0.90 3.27 20.00 16.73
Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss + Antenna Gain
Test Condition
max max
nom nom
min
max min
min max
min
Nordic Original 2 Mbps Receiver Category : 2Freq. P/M (AV) Cable Atten. Antenna Result Limit Margin
Temp. Volt. Reading Loss Loss Gain[MHz] [dBm] [dB] [dB] [dBi] [dBm] [dBm] [dB]2402.0 -7.17 1.58 9.80 0.90 5.11 20.00 14.892441.0 -7.19 1.59 9.80 0.90 5.10 20.00 14.902480.0 -7.28 1.60 9.80 0.90 5.02 20.00 14.982402.0 -5.64 0.95 10.04 0.90 6.25 20.00 13.752441.0 -5.61 0.95 10.04 0.90 6.28 20.00 13.722480.0 -5.63 0.95 10.04 0.90 6.26 20.00 13.742402.0 -5.72 0.95 10.04 0.90 6.17 20.00 13.832441.0 -5.70 0.95 10.04 0.90 6.19 20.00 13.812480.0 -5.71 0.95 10.04 0.90 6.18 20.00 13.822402.0 -8.45 0.95 10.04 0.90 3.44 20.00 16.562441.0 -8.56 0.95 10.04 0.90 3.33 20.00 16.672480.0 -8.69 0.95 10.04 0.90 3.20 20.00 16.802402.0 -8.38 0.95 10.04 0.90 3.51 20.00 16.492441.0 -8.48 0.95 10.04 0.90 3.41 20.00 16.592480.0 -8.61 0.95 10.04 0.90 3.28 20.00 16.72
Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss + Antenna Gain
min
Test Condition
max max
nom nom
min
max min
min max
Test report No. : 11989461S Page : 14 of 28 Issued date : November 28, 2017
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
Power Spectral Density
Test place Shonan EMC Lab. No.5 Shielded Room Report No. 11989461S Date October 20, 2017 Temperature / Humidity 24 deg. C / 51 % RH Engineer Kenichi Adachi Mode Tx
BTLE 1 Mbps
Ch S/A S/A RF Output Result Limit MarginTemp. Volt. Freq. Maximum Total Power Power
Reading Reading[MHz] [dBm/MHz] [dBm] [dBm] [dBm/MHz] [dBm/MHz] [dB]
2402.00 -6.83 -6.76 5.11 5.04 10.00 4.962440.00 -6.97 -6.90 5.10 5.03 10.00 4.972480.00 -7.16 -7.08 5.02 4.94 10.00 5.06
Result [dBm/MHz] = S/A Maximum Reading [dBm/MHz] - S/A Total Power Reading [dBm] (*1) + RF Output Power [dBm] (*2)
(*1) Integrated value of 2400 MHz to 2483.5 MHz
(*2) Refer to RF Output Power
Test Condition
nom nom
BTLE 2 MbpsCh S/A S/A RF Output Result Limit Margin
Temp. Volt. Freq. Maximum Total Power PowerReading Reading
[MHz] [dBm/MHz] [dBm] [dBm] [dBm/MHz] [dBm/MHz] [dB]2402.00 -8.37 -7.21 5.10 3.94 10.00 6.062440.00 -8.47 -7.29 5.10 3.92 10.00 6.082480.00 -8.63 -7.43 5.02 3.82 10.00 6.18
Result [dBm/MHz] = S/A Maximum Reading [dBm/MHz] - S/A Total Power Reading [dBm] (*1) + RF Output Power [dBm] (*2)
(*1) Integrated value of 2400 MHz to 2483.5 MHz
(*2) Refer to RF Output Power
Test Condition
nom nom
ANT 1 MbpsCh S/A S/A RF Output Result Limit Margin
Temp. Volt. Freq. Maximum Total Power PowerReading Reading
[MHz] [dBm/MHz] [dBm] [dBm] [dBm/MHz] [dBm/MHz] [dB]2402.00 -6.96 -6.94 5.11 5.08 10.00 4.922440.00 -6.93 -6.91 5.11 5.09 10.00 4.912480.00 -7.13 -7.11 5.02 5.00 10.00 5.00
Result [dBm/MHz] = S/A Maximum Reading [dBm/MHz] - S/A Total Power Reading [dBm] (*1) + RF Output Power [dBm] (*2)
(*1) Integrated value of 2400 MHz to 2483.5 MHz
(*2) Refer to RF Output Power
Test Condition
nom nom
Nordic Origianl 2 MbpsCh S/A S/A RF Output Result Limit Margin
Temp. Volt. Freq. Maximum Total Power PowerReading Reading
[MHz] [dBm/MHz] [dBm] [dBm] [dBm/MHz] [dBm/MHz] [dB]2402.00 -7.68 -7.31 5.11 4.73 10.00 5.272440.00 -7.63 -7.26 5.10 4.73 10.00 5.272480.00 -7.83 -7.45 5.02 4.65 10.00 5.35
Result [dBm/MHz] = S/A Maximum Reading [dBm/MHz] - S/A Total Power Reading [dBm] (*1) + RF Output Power [dBm] (*2)
(*1) Integrated value of 2400 MHz to 2483.5 MHz
(*2) Refer to RF Output Power
Test Condition
nom nom
Test report No. : 11989461S Page : 15 of 28 Issued date : November 28, 2017
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
Power Spectral Density
BTLE 1 Mbps
Tx 2402 MHz (1/2) Tx 2402 MHz (2/2)
Tx 2440 MHz (1/2) Tx 2440 MHz (2/2)
Tx 2480 MHz (1/2) Tx 2480 MHz (2/2)
Test report No. : 11989461S Page : 16 of 28 Issued date : November 28, 2017
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
Power Spectral Density
BTLE 2 Mbps
Tx 2402 MHz (1/2) Tx 2402 MHz (2/2)
Tx 2440 MHz (1/2) Tx 2440 MHz (2/2)
Tx 2480 MHz Tx 2480 MHz
Test report No. : 11989461S Page : 17 of 28 Issued date : November 28, 2017
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
Power Spectral Density
ANT 1 Mbps
Tx 2402 MHz (1/2) Tx 2402 MHz (2/2)
Tx 2441 MHz (1/2) Tx 2441 MHz (2/2)
Tx 2480 MHz (1/2) Tx 2480 MHz (2/2)
Test report No. : 11989461S Page : 18 of 28 Issued date : November 28, 2017
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
Power Spectral Density
Nordic Original 2 Mbps
Tx 2402 MHz (1/2) Tx 2402 MHz (2/2)
Tx 2441 MHz (1/2) Tx 2441 MHz (2/2)
Tx 2480 MHz (1/2) Tx 2480 MHz (2/2)
Test report No. : 11989461S Page : 19 of 28 Issued date : November 28, 2017
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
Occupied Channel Bandwidth
Test place Shonan EMC Lab. No.5 Shielded Room Report No. 11989461S Date October 20, 2017 Temperature / Humidity 24 deg. C / 51 % RH Engineer Kenichi Adachi Mode Tx, BTLE 1 Mbps
Frequency Bandwidth Result Limit[MHz] [MHz] [MHz] [MHz]2402 1.046 2401.477 > 24002480 1.059 2480.529 < 2483.5
Tx 2402 MHz Tx 2480 MHz
Test report No. : 11989461S Page : 20 of 28 Issued date : November 28, 2017
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
Occupied Channel Bandwidth
Test place Shonan EMC Lab. No.5 Shielded Room Report No. 11989461S Date October 20, 2017 Temperature / Humidity 24 deg. C / 51 % RH Engineer Kenichi Adachi Mode Tx, BTLE 2 Mbps
Frequency Bandwidth Result Limit[MHz] [MHz] [MHz] [MHz]2402 2.080 2400.960 > 24002480 2.079 2481.040 < 2483.5
Tx 2402 MHz Tx 2480 MHz
Test report No. : 11989461S Page : 21 of 28 Issued date : November 28, 2017
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
Occupied Channel Bandwidth
Test place Shonan EMC Lab. No.5 Shielded Room Report No. 11989461S Date October 20, 2017 Temperature / Humidity 24 deg. C / 51 % RH Engineer Kenichi Adachi Mode Tx, ANT 1 Mbps
Frequency Bandwidth Result Limit[MHz] [MHz] [MHz] [MHz]2402 0.890 2401.555 > 24002480 0.918 2480.459 < 2483.5
Tx 2402 MHz Tx 2480 MHz
Test report No. : 11989461S Page : 22 of 28 Issued date : November 28, 2017
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
Occupied Channel Bandwidth
Test place Shonan EMC Lab. No.5 Shielded Room Report No. 11989461S Date October 20, 2017 Temperature / Humidity 24 deg. C / 51 % RH Engineer Kenichi Adachi Mode Tx, Nordic Original 2 Mbps
Frequency Bandwidth Result Limit[MHz] [MHz] [MHz] [MHz]2402 1.780 2401.110 > 24002480 1.766 2480.883 < 2483.5
Tx 2402 MHz Tx 2480 MHz
Test report No. : 11989461S Page : 23 of 28 Issued date : November 28, 2017
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
Transmitter unwanted emissions in the out-of-band domain
Test place Shonan EMC Lab. No.5 Shielded Room Report No. 11989461S Date October 20, 2017 Temperature / Humidity 24 deg. C / 51 % RH Engineer Kenichi Adachi Mode Tx
BTLE 1 MbpsFrequency S/A (AV) Cable Atten. Antenna Result Limit Margin Remarks
Reading Loss Loss Gain[MHz] [dBm/MHz] [dB] [dB] [dBi] [dBm/MHz] [dBm/MHz] [dB]
2398.46 -63.22 1.58 9.80 0.90 -50.94 -20.00 30.94 Lowest ch 2400 MHz - 2 BW2399.50 -58.34 1.58 9.80 0.90 -46.06 -10.00 36.06 Lowest ch 2400 MHz - BW2484.00 -63.73 1.60 9.80 0.90 -51.43 -10.00 41.43 Highest ch 2483.5 MHz + BW2485.06 -65.93 1.60 9.80 0.90 -53.63 -20.00 33.63 Highest ch 2483.5 MHz + 2 BW
BTLE 2 MbpsFrequency S/A (AV) Cable Atten. Antenna Result Limit Margin Remarks
Reading Loss Loss Gain[MHz] [dBm/MHz] [dB] [dB] [dBi] [dBm/MHz] [dBm/MHz] [dB]
2397.42 -61.19 1.58 9.80 0.90 -48.91 -20.00 28.91 Lowest ch 2400 MHz - 2 BW2399.50 -43.58 1.58 9.80 0.90 -31.30 -10.00 21.30 Lowest ch 2400 MHz - BW2484.00 -59.83 1.60 9.80 0.90 -47.53 -10.00 37.53 Highest ch 2483.5 MHz + BW2486.08 -63.46 1.60 9.80 0.90 -51.16 -20.00 31.16 Highest ch 2483.5 MHz + 2 BW
ANT 1 MbpsFrequency S/A (AV) Cable Atten. Antenna Result Limit Margin Remarks
Reading Loss Loss Gain[MHz] [dBm/MHz] [dB] [dB] [dBi] [dBm/MHz] [dBm/MHz] [dB]
2398.50 -62.81 1.58 9.80 0.90 -50.53 -20.00 30.53 Lowest ch 2400 MHz - 2 BW2399.50 -59.12 1.58 9.80 0.90 -46.84 -10.00 36.84 Lowest ch 2400 MHz - BW2484.00 -63.83 1.60 9.80 0.90 -51.53 -10.00 41.53 Highest ch 2483.5 MHz + BW2485.00 -65.65 1.60 9.80 0.90 -53.35 -20.00 33.35 Highest ch 2483.5 MHz + 2 BW
Nordic Original 2 MbpsFrequency S/A (AV) Cable Atten. Antenna Result Limit Margin Remarks
Reading Loss Loss Gain[MHz] [dBm/MHz] [dB] [dB] [dBi] [dBm/MHz] [dBm/MHz] [dB]
2397.72 -60.54 1.58 9.80 0.90 -48.26 -20.00 28.26 Lowest ch 2400 MHz - 2 BW2399.50 -48.09 1.58 9.80 0.90 -35.81 -10.00 25.81 Lowest ch 2400 MHz - BW2484.00 -60.18 1.60 9.80 0.90 -47.88 -10.00 37.88 Highest ch 2483.5 MHz + BW2485.77 -63.06 1.60 9.80 0.90 -50.76 -20.00 30.76 Highest ch 2483.5 MHz + 2 BW
Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss + Antenna Gain
*Above test result was maximum value on each 1 BW.
Test report No. : 11989461S Page : 24 of 28 Issued date : November 28, 2017
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
Receiver Blocking
Report No. 11989461S Test place Shonan EMC Lab. No.5 Shielded Room Date October 23, 2017 Temperature / Humidity 25 deg. C / 61 % RH Engineer Hiroyuki Morikawa Mode Receiving, ANT 1 Mbps
Lowest Channel Highest ChannelPmin -100.55 -100.22
Pmin + 6 dB -94.55 -94.22
Receiver Category 2 equipment
2380 02503.5 02300 0
2583.5 02380 0
2503.5 02300 0
2583.5 0
*Pmin is the minimum level of wanted signal (in dBm) required to meet the minimum performance criterion a PER less than or equal to 10 % in the absence of any blocking signal.*The test was performed Blocking signal power levels corrected by the actual antenna assembly gain.
ResultPER(%)
LimitPER(%)
Blocking signal power (corrected by the actualantenna assembly gain)
(dBm)
-56.1
-46.1
≦10
≦10
Pmin + 6 dB -47
-56.1
-46.1
Pmin + 6 dB -57
Pmin + 6 dB -57
Pmin + 6 dB -47
HighestChannel
Wanted signal meanpower from
companion device(dBm)
MeasuredReceiver Sensitivity
(corrected by the actual antenna assemblygain)
OperatingChannel
Wanted signal meanpower from
companion device(dBm)
Blocking signalfrequency
(MHz)
Blocking signal power(dBm)
LowestChannel
*1) Blocking signal power was adjusted by product antenna gain 0.9 dBi.
Test report No. : 11989461S Page : 25 of 28 Issued date : November 28, 2017
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
CONDUCTED METHODS SYSTEM BLOCK DIAGRAM of Receiver Blocking
PC Competitor
Power Splitters/ Combiners
Signal Generator
EUT Attenuator (20dB * 4
+ 10 or 0 dB)
Step Attenuator
Test report No. : 11989461S Page : 26 of 28 Issued date : November 28, 2017
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
APPENDIX 2: Test instruments Test Equipment
Control No. Instrument Manufacturer Model No Serial No Test Item Calibration Date * Interval(month)
SPM-06 Power Meter Anritsu ML2495A 0850009 AT 2017/04/25 * 12
SPSS-03 Power sensor Anritsu MA2411B 0917063 AT 2017/04/25 * 12
SSA-03 Spectrum Analyzer Agilent E4448A MY48250152 AT, RB 2017/08/20 * 12
SAT10-14 Attenuator Weinschel Corp. 54A-10 81595 AT 2017/04/20 * 12
SCC-G13 Coaxial Cable Suhner SUCOFLEX 102 31599/2 AT, RB 2017/03/23 * 12
SOS-09 Humidity Indicator A&D AD-5681 4061484 AT, RB 2016/12/13 * 12
SCH-01 Temperature and Humidity Chamber
Espec PL-1KT 14020837 AT 2017/04/17 * 12
KTS-07 Digital Tester SANWA PC500 7019232 AT, RB 2017/10/11 * 12
CCC-W01 Micro Wave Cable SUHNER SUCOFLEX102 MY3662/2 AT 2017/05/19 * 12
CAT10-17 10dB Fixed Atten. Weinschel 54A-10 56251 AT 2017/05/19 * 12
CPM-16 Peak Power Analyzer Agilent 8990B MY51000276 AT 2017/06/09 * 12
CPSO-24 Power Sensor Agilent N1923A MY54070024 AT 2017/06/09 * 12
SCC-G11 Coaxial Cable Suhner SUCOFLEX 102 31595/2 RB 2017/03/23 * 12
SCC-G14 Coaxial Cable Suhner SUCOFLEX 102 31600/2 RB 2017/03/23 * 12
SPSC-03 Power Splitters/Combiners
Mini-Circuits ZFSC-2-10G+ - RB 2017/04/21 * 12
SSG-01 Signal Generator Agilent E4438C MY47271584 RB 2017/03/06 * 12
SAT10-01 Attenuator JFW 50HF-010N - RB 2017/02/09 * 12
SAT20-06 Attenuator Weinschel Corp. 54A-20 31506 RB 2017/04/20 * 12
SAT20-07 Attenuator Weinschel Corp. 54A-20 31484 RB 2017/04/20 * 12
SAT20-03 Attenuator Agilent 8493C-020 74891 RB 2017/03/23 * 12
SAT20-01 Attenuator(above1GHz)
Agilent 8493C-020 74889 RB 2016/11/07 * 12
SAT10-13 Attenuator Weinschel Corp. 54A-10 81626 RB 2017/03/23 * 12
The expiration date of the calibration is the end of the expired month. All equipment is calibrated with valid calibrations. Each measurement data is traceable to the national or international standards. As for some calibrations performed after the tested dates, those test equipment have been controlled by means of an unbroken chains of calibrations.
Test Item: AT: Antenna Terminal Conducted test RB: Receiver blocking test
Test report No. : 11989461S Page : 27 of 28 Issued date : November 28, 2017
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
APPENDIX 3: Photographs of test setup
Antenna terminal conducted tests other than Receiver Blocking
(Kashima EMC Lab.)
(Shonan EMC Lab.)
Test report No. : 11989461S Page : 28 of 28 Issued date : November 28, 2017
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
Receiver Blocking
End of Report