TEST REPORT Reliabil ity Laboratory Report No HC500S8201 4
Page 1 of 4
Date June 22 201 4
NEOUSYS TECHNOLOGY INC
13F-l NO 1 BAOSHENG RD YONGHE DIST
NEW TAIPEI CITY TAIWAN R Oc
The following merchandise was submitted and identified by the vendor as
Product Description Nuvo-31OOVTC
StyleItem No Nuvo-3100VTC-ISDC No 1
Quantity Totall set
Testing Period May 26 2014 to May 27 2014
We have tested the submitted sample(s) as requested and the following results were obtained
Test Required (According to clients test specification please see following sheets in detail)
1 High Temperature Humidity Test
Test Results -PLEASE SEE AITACHEDSHEETS shy
Signed for and on behalf of SGS TAIWAN Ltd
Hank Chiou Asst Supervisor
TEST REPORT Rel iability Laboratory Report No HC5005820 14
Page 2 of 4
1 High Temperatme Humidity Test
Test Equipment
Name Brand Model Selial No
Programmable Temperature amp Humidity Chamber KSON THS-C6T-1 50+LN2 A0129
Lab Envirownental Conditions
Ambient temperatme (25 + 3 ) DC
Ambient humidity ( 55 + 20) RH
Test Method Specification
Sample condition Operating ( Execute test program Bum-In V71 Pro and 11Ul POE Device)
Temperature 70 degC
Test bumidity 90RH
Duration 20 Homs
bull Examine the appearance of specimen(s) by visual check and perfonn functional check after this test
bull Functional check C01lllect the specimen with Jated power then tum on the power of specimen Execute the w1 program
Bum In Test V7 1 Pro-Live Results and nul POE Device while perfonn fimctional check
1 B1Dll In TestV71 Pro Test item CPU 100 RAM 100 2D Graphics 100 3D Graphics 100
Com port(s) lOooo
2 POE Device (2 pieces) IMAGINGSOURCE (DMK23G618) full nul
TEST REPORT Reliability Laboratory Report No HC5005812014
Page 3 of 4
Specimen
Style Item No Nuvo-3100VTC-I5DCNol
Quantity Total 1 set
Test Resultshy
~m Appearance check Functional check
(visual check) Style Item No
Nuvo-3100VTC-ISDC No1 NormalNo visible damage
TEST REPORT Reliability Laboratory Report No HC5005820 14
Page 4 of 4
Test Photos
1 Appearance of specimen
2 High Temperature Humidity Test 3 Functional check
- - - The End of Test Report - - shy
Unless otherNlsa strted the results shaMl in 111 test report reamper co the sample(s) tested and such sample(s) iie reIUIed for 90 days on~ TbIS test repor1 C3MOI be reproduced exCltlllC In fll1Ihout prior WTiIten permission ctthe Company If~-l tbtI1~1iI ampAmiddot IjIJIlfi90~middot fH1~1 llIJiJJlfOT middotfiiJllt9lO1 middot This document is issued b) the Company subJect to itS GIiileral diI 01 seMce pl1nted ltMrIeaI 3Vall3llle on fequelil or accesSble a1 ~~~cancIIJmlt 500 for electronic format docunents subject to Tenns and Condtioos for EJectronlc Documents OIl ~ ~ ~Attention is drawn to the limJlallOn 0 ~n ana n issues ltlerned theminVry holder ct this dorument is advised that iIlform~ampiifi- fiiifiOn COfropanys fild1lOS al DIe tine 01 ts IntervenJon cny and gtMtOO the of Clients instrucliDns It any The Companys sole responsibility is to ts ctIent and tills document does not eXooorIle paIIIes to a trIIsactlon IIlIm ex~ al llleir IIgbIs and obIlgaUms mdef the tl1lnsaction docnents This downent caMDI be reproduced except in fIIll gtM1out prior writ1lfl IlProval of DIe CoolpalY Vry ~rized eratIoo forgery or fa5~1on olDIe content or appear-mce 0I 11lis IIocumenI is unlawful and olrenders may be prosecuted ID the fillies extent 01 Itle law
No31 No33 NoJ5VrClyDl RoIdNewTaipei InIbohlIIaII YUu Disid NewTaipei Ciy laioIW~rtJiUJt~1l~31 It 33 It35 No 134 Wu ~ Ibid New Taipei InoitRoIIaII MJw Dmid New Taipei CiyTltiwa-ifIrltIf~alUilt lIIb L4 134
~ JIfltttff-ttAl-amp)-j ~ ~ 1t (886-2 2299-3279 r (886-2) 2299-9558 _ iW5gsCXJm - - - --- Member 01 SOO Group
TEST REPORT Reliabil ity Laboratory Report No H C502642014
Page 1 of 4
Date June 22 201 4
NEOUSYS TECHNOLOGY INC
13F-l NO 1 BAOSHENG RD YONGHE DIST
NEW TAIPEI CITY TAIWAN ROc
The following merchandise was submitted and identified by the vendor as
Product Description Nuvo-3100VTC
Styielltem No Nuvo-3100VTC-I5DCI No 1
Quantity Total 1 set
Testing Period May 26 2014 to May 27 201 4
We have tested the submitted sample(s) as requested and the following results were obtained
Test Required (According to clients test specification please see following sheets in detail)
1 Low Temperature Test
Test Results -PLEASESEEATTACHEDSHEETS shy
Signed for and on behalf of SGS TAIWAN Ltd
I
Hank Chiou Asst Supervisor
TEST REPORT Reliabi lity Laboratory RepOli No HC5026412014
Page 2 of 4
1 Low Temperature Test
Test Equipment
Namr Brand Model SeliaJ No
Programmable Temperamre amp Humidity Chamber KSON TIIS-C6T- lSO+LN2 A0129
Lab Environmental Conditions
Ambient temperature ( 25 + 3) DC
Ambient humidity (55 + 20) RH
Test Method Specification
Sample condition Operating ( Continuous execute Power ONI OFF )
Temperature -40 DC
Dmation 24 Horus
bull Examine the appearance of specimen(s) by visual check and perfonn fimctional check after this test
bull Functional check Connect the specimen w ith rated power and PC via RS232 Execute diatmostic software
Boot_DVT then examine whether the Booting fimction Power ONOFF of specimen could be work nonnally or not
The Boot_DVT performs sequence as below
1 Power on the UUT
2 Wait for UUT booting into DOS and send out a text message via RS232
3 Once the text message is received and confumed as correct the Boot_DVT records a successful booting process
and power off the UUT
4 Wait for couple minutes to make sure the UUT is cool dowll
5 Repeat stepl
Unless oIIIelWise stated the results shown tIlis test repoot reler onIyO the samples) tested and such sal11lle(s) am Rlti ined lor 90 days only This test report CdflIlOI be 1eIgtfOduced exCE$llIn fuji without prior written pessIon of tile Company 1tj~imsttII ~fIittr 1i1Il~1I bulltZJilgtU fit~jj-l~lHI 90 7lt bull lttitdl0 ilJ iIilJfiiJ This doc-nent is issued by the Company subject to itS GOOerlIICOridliiOOS of SeMce plinted overJeat available on request or accesSible at T~ ond amp~ and lor electronic fOlllld dOClnlOnts subjectO Tenns ond Conditions lor Electrunic Documents at ~~ccmenns ~htm AIIenIlon is dra III IIle IimltlbOll 0 emrii jOrjSdidion issues defiled tIlerein Ally hoIdelt of tIlis documenI is advised that infonn~ iIid hiiriiln~ COfnpanys tndlOgS at tile ume 01 its rterventJon only anti MlIWl the limits of Clients instJUcIions W any The Companys sole responsibolity is to lis Client and IhIs documeot does not exanera1e pIIties to a ITansacl10n from exercising al lheir lights and obIgatiOns ~def the transactJon doclHlerlts This docunent camot be reproduced excep in rull wiIlIout pIior written 0IPPf0Yd1 of he Comp~ Ally UIlalIhoized a_ lorgelY or Ial8lfication of IhI 00fIIIf1t or appearance of tIlis document is unlaWlul and oIIeoders may be prosecuted to he Miesl extent of he 1aIII
~31 Na33No35 0Iy0m Raad Now IrWtisI Pak NJIu DiIbI NewTaipIi CiyTaioaIIMll1iftlUt1l 11111 31 It 33 35 ItINo134 WU ~ Rood New Taipei IIdSria Ptlt WUw Disht NewTaipei Cly Taiai~bull La1lHln IiLLJI 134 It
~ lt~tflmiddot-itafSHf fl~ ~ 1(8862) 2299-3279 r B86-~) 229~9558 -lWsuscom MemberfSGS Group
TEST REPORT Reliability Laboratory RepOli No HC5026412014
Page 3 of 4
Specimen
Style Item No Nuvo-3100VTC-I5DC No1
Quantity Total 1 set
Test Resultmiddot
~m Style Item No
Appearance check (visual check)
Functional check
Nuvo-3100VTC-ISDC No 1 No visible damage Normal
TEST REPORT Rel iability Laboratory RepOItNo HC5026412014
Page 4 of 4
Test Photos
1 Appearance of specimen
4 Functional check
The End of Test Report
TEST REPORT Rel iability Laboratory Report No HC5005820 14
Page 2 of 4
1 High Temperatme Humidity Test
Test Equipment
Name Brand Model Selial No
Programmable Temperature amp Humidity Chamber KSON THS-C6T-1 50+LN2 A0129
Lab Envirownental Conditions
Ambient temperatme (25 + 3 ) DC
Ambient humidity ( 55 + 20) RH
Test Method Specification
Sample condition Operating ( Execute test program Bum-In V71 Pro and 11Ul POE Device)
Temperature 70 degC
Test bumidity 90RH
Duration 20 Homs
bull Examine the appearance of specimen(s) by visual check and perfonn functional check after this test
bull Functional check C01lllect the specimen with Jated power then tum on the power of specimen Execute the w1 program
Bum In Test V7 1 Pro-Live Results and nul POE Device while perfonn fimctional check
1 B1Dll In TestV71 Pro Test item CPU 100 RAM 100 2D Graphics 100 3D Graphics 100
Com port(s) lOooo
2 POE Device (2 pieces) IMAGINGSOURCE (DMK23G618) full nul
TEST REPORT Reliability Laboratory Report No HC5005812014
Page 3 of 4
Specimen
Style Item No Nuvo-3100VTC-I5DCNol
Quantity Total 1 set
Test Resultshy
~m Appearance check Functional check
(visual check) Style Item No
Nuvo-3100VTC-ISDC No1 NormalNo visible damage
TEST REPORT Reliability Laboratory Report No HC5005820 14
Page 4 of 4
Test Photos
1 Appearance of specimen
2 High Temperature Humidity Test 3 Functional check
- - - The End of Test Report - - shy
Unless otherNlsa strted the results shaMl in 111 test report reamper co the sample(s) tested and such sample(s) iie reIUIed for 90 days on~ TbIS test repor1 C3MOI be reproduced exCltlllC In fll1Ihout prior WTiIten permission ctthe Company If~-l tbtI1~1iI ampAmiddot IjIJIlfi90~middot fH1~1 llIJiJJlfOT middotfiiJllt9lO1 middot This document is issued b) the Company subJect to itS GIiileral diI 01 seMce pl1nted ltMrIeaI 3Vall3llle on fequelil or accesSble a1 ~~~cancIIJmlt 500 for electronic format docunents subject to Tenns and Condtioos for EJectronlc Documents OIl ~ ~ ~Attention is drawn to the limJlallOn 0 ~n ana n issues ltlerned theminVry holder ct this dorument is advised that iIlform~ampiifi- fiiifiOn COfropanys fild1lOS al DIe tine 01 ts IntervenJon cny and gtMtOO the of Clients instrucliDns It any The Companys sole responsibility is to ts ctIent and tills document does not eXooorIle paIIIes to a trIIsactlon IIlIm ex~ al llleir IIgbIs and obIlgaUms mdef the tl1lnsaction docnents This downent caMDI be reproduced except in fIIll gtM1out prior writ1lfl IlProval of DIe CoolpalY Vry ~rized eratIoo forgery or fa5~1on olDIe content or appear-mce 0I 11lis IIocumenI is unlawful and olrenders may be prosecuted ID the fillies extent 01 Itle law
No31 No33 NoJ5VrClyDl RoIdNewTaipei InIbohlIIaII YUu Disid NewTaipei Ciy laioIW~rtJiUJt~1l~31 It 33 It35 No 134 Wu ~ Ibid New Taipei InoitRoIIaII MJw Dmid New Taipei CiyTltiwa-ifIrltIf~alUilt lIIb L4 134
~ JIfltttff-ttAl-amp)-j ~ ~ 1t (886-2 2299-3279 r (886-2) 2299-9558 _ iW5gsCXJm - - - --- Member 01 SOO Group
TEST REPORT Reliabil ity Laboratory Report No H C502642014
Page 1 of 4
Date June 22 201 4
NEOUSYS TECHNOLOGY INC
13F-l NO 1 BAOSHENG RD YONGHE DIST
NEW TAIPEI CITY TAIWAN ROc
The following merchandise was submitted and identified by the vendor as
Product Description Nuvo-3100VTC
Styielltem No Nuvo-3100VTC-I5DCI No 1
Quantity Total 1 set
Testing Period May 26 2014 to May 27 201 4
We have tested the submitted sample(s) as requested and the following results were obtained
Test Required (According to clients test specification please see following sheets in detail)
1 Low Temperature Test
Test Results -PLEASESEEATTACHEDSHEETS shy
Signed for and on behalf of SGS TAIWAN Ltd
I
Hank Chiou Asst Supervisor
TEST REPORT Reliabi lity Laboratory RepOli No HC5026412014
Page 2 of 4
1 Low Temperature Test
Test Equipment
Namr Brand Model SeliaJ No
Programmable Temperamre amp Humidity Chamber KSON TIIS-C6T- lSO+LN2 A0129
Lab Environmental Conditions
Ambient temperature ( 25 + 3) DC
Ambient humidity (55 + 20) RH
Test Method Specification
Sample condition Operating ( Continuous execute Power ONI OFF )
Temperature -40 DC
Dmation 24 Horus
bull Examine the appearance of specimen(s) by visual check and perfonn fimctional check after this test
bull Functional check Connect the specimen w ith rated power and PC via RS232 Execute diatmostic software
Boot_DVT then examine whether the Booting fimction Power ONOFF of specimen could be work nonnally or not
The Boot_DVT performs sequence as below
1 Power on the UUT
2 Wait for UUT booting into DOS and send out a text message via RS232
3 Once the text message is received and confumed as correct the Boot_DVT records a successful booting process
and power off the UUT
4 Wait for couple minutes to make sure the UUT is cool dowll
5 Repeat stepl
Unless oIIIelWise stated the results shown tIlis test repoot reler onIyO the samples) tested and such sal11lle(s) am Rlti ined lor 90 days only This test report CdflIlOI be 1eIgtfOduced exCE$llIn fuji without prior written pessIon of tile Company 1tj~imsttII ~fIittr 1i1Il~1I bulltZJilgtU fit~jj-l~lHI 90 7lt bull lttitdl0 ilJ iIilJfiiJ This doc-nent is issued by the Company subject to itS GOOerlIICOridliiOOS of SeMce plinted overJeat available on request or accesSible at T~ ond amp~ and lor electronic fOlllld dOClnlOnts subjectO Tenns ond Conditions lor Electrunic Documents at ~~ccmenns ~htm AIIenIlon is dra III IIle IimltlbOll 0 emrii jOrjSdidion issues defiled tIlerein Ally hoIdelt of tIlis documenI is advised that infonn~ iIid hiiriiln~ COfnpanys tndlOgS at tile ume 01 its rterventJon only anti MlIWl the limits of Clients instJUcIions W any The Companys sole responsibolity is to lis Client and IhIs documeot does not exanera1e pIIties to a ITansacl10n from exercising al lheir lights and obIgatiOns ~def the transactJon doclHlerlts This docunent camot be reproduced excep in rull wiIlIout pIior written 0IPPf0Yd1 of he Comp~ Ally UIlalIhoized a_ lorgelY or Ial8lfication of IhI 00fIIIf1t or appearance of tIlis document is unlaWlul and oIIeoders may be prosecuted to he Miesl extent of he 1aIII
~31 Na33No35 0Iy0m Raad Now IrWtisI Pak NJIu DiIbI NewTaipIi CiyTaioaIIMll1iftlUt1l 11111 31 It 33 35 ItINo134 WU ~ Rood New Taipei IIdSria Ptlt WUw Disht NewTaipei Cly Taiai~bull La1lHln IiLLJI 134 It
~ lt~tflmiddot-itafSHf fl~ ~ 1(8862) 2299-3279 r B86-~) 229~9558 -lWsuscom MemberfSGS Group
TEST REPORT Reliability Laboratory RepOli No HC5026412014
Page 3 of 4
Specimen
Style Item No Nuvo-3100VTC-I5DC No1
Quantity Total 1 set
Test Resultmiddot
~m Style Item No
Appearance check (visual check)
Functional check
Nuvo-3100VTC-ISDC No 1 No visible damage Normal
TEST REPORT Rel iability Laboratory RepOItNo HC5026412014
Page 4 of 4
Test Photos
1 Appearance of specimen
4 Functional check
The End of Test Report
TEST REPORT Reliability Laboratory Report No HC5005812014
Page 3 of 4
Specimen
Style Item No Nuvo-3100VTC-I5DCNol
Quantity Total 1 set
Test Resultshy
~m Appearance check Functional check
(visual check) Style Item No
Nuvo-3100VTC-ISDC No1 NormalNo visible damage
TEST REPORT Reliability Laboratory Report No HC5005820 14
Page 4 of 4
Test Photos
1 Appearance of specimen
2 High Temperature Humidity Test 3 Functional check
- - - The End of Test Report - - shy
Unless otherNlsa strted the results shaMl in 111 test report reamper co the sample(s) tested and such sample(s) iie reIUIed for 90 days on~ TbIS test repor1 C3MOI be reproduced exCltlllC In fll1Ihout prior WTiIten permission ctthe Company If~-l tbtI1~1iI ampAmiddot IjIJIlfi90~middot fH1~1 llIJiJJlfOT middotfiiJllt9lO1 middot This document is issued b) the Company subJect to itS GIiileral diI 01 seMce pl1nted ltMrIeaI 3Vall3llle on fequelil or accesSble a1 ~~~cancIIJmlt 500 for electronic format docunents subject to Tenns and Condtioos for EJectronlc Documents OIl ~ ~ ~Attention is drawn to the limJlallOn 0 ~n ana n issues ltlerned theminVry holder ct this dorument is advised that iIlform~ampiifi- fiiifiOn COfropanys fild1lOS al DIe tine 01 ts IntervenJon cny and gtMtOO the of Clients instrucliDns It any The Companys sole responsibility is to ts ctIent and tills document does not eXooorIle paIIIes to a trIIsactlon IIlIm ex~ al llleir IIgbIs and obIlgaUms mdef the tl1lnsaction docnents This downent caMDI be reproduced except in fIIll gtM1out prior writ1lfl IlProval of DIe CoolpalY Vry ~rized eratIoo forgery or fa5~1on olDIe content or appear-mce 0I 11lis IIocumenI is unlawful and olrenders may be prosecuted ID the fillies extent 01 Itle law
No31 No33 NoJ5VrClyDl RoIdNewTaipei InIbohlIIaII YUu Disid NewTaipei Ciy laioIW~rtJiUJt~1l~31 It 33 It35 No 134 Wu ~ Ibid New Taipei InoitRoIIaII MJw Dmid New Taipei CiyTltiwa-ifIrltIf~alUilt lIIb L4 134
~ JIfltttff-ttAl-amp)-j ~ ~ 1t (886-2 2299-3279 r (886-2) 2299-9558 _ iW5gsCXJm - - - --- Member 01 SOO Group
TEST REPORT Reliabil ity Laboratory Report No H C502642014
Page 1 of 4
Date June 22 201 4
NEOUSYS TECHNOLOGY INC
13F-l NO 1 BAOSHENG RD YONGHE DIST
NEW TAIPEI CITY TAIWAN ROc
The following merchandise was submitted and identified by the vendor as
Product Description Nuvo-3100VTC
Styielltem No Nuvo-3100VTC-I5DCI No 1
Quantity Total 1 set
Testing Period May 26 2014 to May 27 201 4
We have tested the submitted sample(s) as requested and the following results were obtained
Test Required (According to clients test specification please see following sheets in detail)
1 Low Temperature Test
Test Results -PLEASESEEATTACHEDSHEETS shy
Signed for and on behalf of SGS TAIWAN Ltd
I
Hank Chiou Asst Supervisor
TEST REPORT Reliabi lity Laboratory RepOli No HC5026412014
Page 2 of 4
1 Low Temperature Test
Test Equipment
Namr Brand Model SeliaJ No
Programmable Temperamre amp Humidity Chamber KSON TIIS-C6T- lSO+LN2 A0129
Lab Environmental Conditions
Ambient temperature ( 25 + 3) DC
Ambient humidity (55 + 20) RH
Test Method Specification
Sample condition Operating ( Continuous execute Power ONI OFF )
Temperature -40 DC
Dmation 24 Horus
bull Examine the appearance of specimen(s) by visual check and perfonn fimctional check after this test
bull Functional check Connect the specimen w ith rated power and PC via RS232 Execute diatmostic software
Boot_DVT then examine whether the Booting fimction Power ONOFF of specimen could be work nonnally or not
The Boot_DVT performs sequence as below
1 Power on the UUT
2 Wait for UUT booting into DOS and send out a text message via RS232
3 Once the text message is received and confumed as correct the Boot_DVT records a successful booting process
and power off the UUT
4 Wait for couple minutes to make sure the UUT is cool dowll
5 Repeat stepl
Unless oIIIelWise stated the results shown tIlis test repoot reler onIyO the samples) tested and such sal11lle(s) am Rlti ined lor 90 days only This test report CdflIlOI be 1eIgtfOduced exCE$llIn fuji without prior written pessIon of tile Company 1tj~imsttII ~fIittr 1i1Il~1I bulltZJilgtU fit~jj-l~lHI 90 7lt bull lttitdl0 ilJ iIilJfiiJ This doc-nent is issued by the Company subject to itS GOOerlIICOridliiOOS of SeMce plinted overJeat available on request or accesSible at T~ ond amp~ and lor electronic fOlllld dOClnlOnts subjectO Tenns ond Conditions lor Electrunic Documents at ~~ccmenns ~htm AIIenIlon is dra III IIle IimltlbOll 0 emrii jOrjSdidion issues defiled tIlerein Ally hoIdelt of tIlis documenI is advised that infonn~ iIid hiiriiln~ COfnpanys tndlOgS at tile ume 01 its rterventJon only anti MlIWl the limits of Clients instJUcIions W any The Companys sole responsibolity is to lis Client and IhIs documeot does not exanera1e pIIties to a ITansacl10n from exercising al lheir lights and obIgatiOns ~def the transactJon doclHlerlts This docunent camot be reproduced excep in rull wiIlIout pIior written 0IPPf0Yd1 of he Comp~ Ally UIlalIhoized a_ lorgelY or Ial8lfication of IhI 00fIIIf1t or appearance of tIlis document is unlaWlul and oIIeoders may be prosecuted to he Miesl extent of he 1aIII
~31 Na33No35 0Iy0m Raad Now IrWtisI Pak NJIu DiIbI NewTaipIi CiyTaioaIIMll1iftlUt1l 11111 31 It 33 35 ItINo134 WU ~ Rood New Taipei IIdSria Ptlt WUw Disht NewTaipei Cly Taiai~bull La1lHln IiLLJI 134 It
~ lt~tflmiddot-itafSHf fl~ ~ 1(8862) 2299-3279 r B86-~) 229~9558 -lWsuscom MemberfSGS Group
TEST REPORT Reliability Laboratory RepOli No HC5026412014
Page 3 of 4
Specimen
Style Item No Nuvo-3100VTC-I5DC No1
Quantity Total 1 set
Test Resultmiddot
~m Style Item No
Appearance check (visual check)
Functional check
Nuvo-3100VTC-ISDC No 1 No visible damage Normal
TEST REPORT Rel iability Laboratory RepOItNo HC5026412014
Page 4 of 4
Test Photos
1 Appearance of specimen
4 Functional check
The End of Test Report
TEST REPORT Reliability Laboratory Report No HC5005820 14
Page 4 of 4
Test Photos
1 Appearance of specimen
2 High Temperature Humidity Test 3 Functional check
- - - The End of Test Report - - shy
Unless otherNlsa strted the results shaMl in 111 test report reamper co the sample(s) tested and such sample(s) iie reIUIed for 90 days on~ TbIS test repor1 C3MOI be reproduced exCltlllC In fll1Ihout prior WTiIten permission ctthe Company If~-l tbtI1~1iI ampAmiddot IjIJIlfi90~middot fH1~1 llIJiJJlfOT middotfiiJllt9lO1 middot This document is issued b) the Company subJect to itS GIiileral diI 01 seMce pl1nted ltMrIeaI 3Vall3llle on fequelil or accesSble a1 ~~~cancIIJmlt 500 for electronic format docunents subject to Tenns and Condtioos for EJectronlc Documents OIl ~ ~ ~Attention is drawn to the limJlallOn 0 ~n ana n issues ltlerned theminVry holder ct this dorument is advised that iIlform~ampiifi- fiiifiOn COfropanys fild1lOS al DIe tine 01 ts IntervenJon cny and gtMtOO the of Clients instrucliDns It any The Companys sole responsibility is to ts ctIent and tills document does not eXooorIle paIIIes to a trIIsactlon IIlIm ex~ al llleir IIgbIs and obIlgaUms mdef the tl1lnsaction docnents This downent caMDI be reproduced except in fIIll gtM1out prior writ1lfl IlProval of DIe CoolpalY Vry ~rized eratIoo forgery or fa5~1on olDIe content or appear-mce 0I 11lis IIocumenI is unlawful and olrenders may be prosecuted ID the fillies extent 01 Itle law
No31 No33 NoJ5VrClyDl RoIdNewTaipei InIbohlIIaII YUu Disid NewTaipei Ciy laioIW~rtJiUJt~1l~31 It 33 It35 No 134 Wu ~ Ibid New Taipei InoitRoIIaII MJw Dmid New Taipei CiyTltiwa-ifIrltIf~alUilt lIIb L4 134
~ JIfltttff-ttAl-amp)-j ~ ~ 1t (886-2 2299-3279 r (886-2) 2299-9558 _ iW5gsCXJm - - - --- Member 01 SOO Group
TEST REPORT Reliabil ity Laboratory Report No H C502642014
Page 1 of 4
Date June 22 201 4
NEOUSYS TECHNOLOGY INC
13F-l NO 1 BAOSHENG RD YONGHE DIST
NEW TAIPEI CITY TAIWAN ROc
The following merchandise was submitted and identified by the vendor as
Product Description Nuvo-3100VTC
Styielltem No Nuvo-3100VTC-I5DCI No 1
Quantity Total 1 set
Testing Period May 26 2014 to May 27 201 4
We have tested the submitted sample(s) as requested and the following results were obtained
Test Required (According to clients test specification please see following sheets in detail)
1 Low Temperature Test
Test Results -PLEASESEEATTACHEDSHEETS shy
Signed for and on behalf of SGS TAIWAN Ltd
I
Hank Chiou Asst Supervisor
TEST REPORT Reliabi lity Laboratory RepOli No HC5026412014
Page 2 of 4
1 Low Temperature Test
Test Equipment
Namr Brand Model SeliaJ No
Programmable Temperamre amp Humidity Chamber KSON TIIS-C6T- lSO+LN2 A0129
Lab Environmental Conditions
Ambient temperature ( 25 + 3) DC
Ambient humidity (55 + 20) RH
Test Method Specification
Sample condition Operating ( Continuous execute Power ONI OFF )
Temperature -40 DC
Dmation 24 Horus
bull Examine the appearance of specimen(s) by visual check and perfonn fimctional check after this test
bull Functional check Connect the specimen w ith rated power and PC via RS232 Execute diatmostic software
Boot_DVT then examine whether the Booting fimction Power ONOFF of specimen could be work nonnally or not
The Boot_DVT performs sequence as below
1 Power on the UUT
2 Wait for UUT booting into DOS and send out a text message via RS232
3 Once the text message is received and confumed as correct the Boot_DVT records a successful booting process
and power off the UUT
4 Wait for couple minutes to make sure the UUT is cool dowll
5 Repeat stepl
Unless oIIIelWise stated the results shown tIlis test repoot reler onIyO the samples) tested and such sal11lle(s) am Rlti ined lor 90 days only This test report CdflIlOI be 1eIgtfOduced exCE$llIn fuji without prior written pessIon of tile Company 1tj~imsttII ~fIittr 1i1Il~1I bulltZJilgtU fit~jj-l~lHI 90 7lt bull lttitdl0 ilJ iIilJfiiJ This doc-nent is issued by the Company subject to itS GOOerlIICOridliiOOS of SeMce plinted overJeat available on request or accesSible at T~ ond amp~ and lor electronic fOlllld dOClnlOnts subjectO Tenns ond Conditions lor Electrunic Documents at ~~ccmenns ~htm AIIenIlon is dra III IIle IimltlbOll 0 emrii jOrjSdidion issues defiled tIlerein Ally hoIdelt of tIlis documenI is advised that infonn~ iIid hiiriiln~ COfnpanys tndlOgS at tile ume 01 its rterventJon only anti MlIWl the limits of Clients instJUcIions W any The Companys sole responsibolity is to lis Client and IhIs documeot does not exanera1e pIIties to a ITansacl10n from exercising al lheir lights and obIgatiOns ~def the transactJon doclHlerlts This docunent camot be reproduced excep in rull wiIlIout pIior written 0IPPf0Yd1 of he Comp~ Ally UIlalIhoized a_ lorgelY or Ial8lfication of IhI 00fIIIf1t or appearance of tIlis document is unlaWlul and oIIeoders may be prosecuted to he Miesl extent of he 1aIII
~31 Na33No35 0Iy0m Raad Now IrWtisI Pak NJIu DiIbI NewTaipIi CiyTaioaIIMll1iftlUt1l 11111 31 It 33 35 ItINo134 WU ~ Rood New Taipei IIdSria Ptlt WUw Disht NewTaipei Cly Taiai~bull La1lHln IiLLJI 134 It
~ lt~tflmiddot-itafSHf fl~ ~ 1(8862) 2299-3279 r B86-~) 229~9558 -lWsuscom MemberfSGS Group
TEST REPORT Reliability Laboratory RepOli No HC5026412014
Page 3 of 4
Specimen
Style Item No Nuvo-3100VTC-I5DC No1
Quantity Total 1 set
Test Resultmiddot
~m Style Item No
Appearance check (visual check)
Functional check
Nuvo-3100VTC-ISDC No 1 No visible damage Normal
TEST REPORT Rel iability Laboratory RepOItNo HC5026412014
Page 4 of 4
Test Photos
1 Appearance of specimen
4 Functional check
The End of Test Report
TEST REPORT Reliabil ity Laboratory Report No H C502642014
Page 1 of 4
Date June 22 201 4
NEOUSYS TECHNOLOGY INC
13F-l NO 1 BAOSHENG RD YONGHE DIST
NEW TAIPEI CITY TAIWAN ROc
The following merchandise was submitted and identified by the vendor as
Product Description Nuvo-3100VTC
Styielltem No Nuvo-3100VTC-I5DCI No 1
Quantity Total 1 set
Testing Period May 26 2014 to May 27 201 4
We have tested the submitted sample(s) as requested and the following results were obtained
Test Required (According to clients test specification please see following sheets in detail)
1 Low Temperature Test
Test Results -PLEASESEEATTACHEDSHEETS shy
Signed for and on behalf of SGS TAIWAN Ltd
I
Hank Chiou Asst Supervisor
TEST REPORT Reliabi lity Laboratory RepOli No HC5026412014
Page 2 of 4
1 Low Temperature Test
Test Equipment
Namr Brand Model SeliaJ No
Programmable Temperamre amp Humidity Chamber KSON TIIS-C6T- lSO+LN2 A0129
Lab Environmental Conditions
Ambient temperature ( 25 + 3) DC
Ambient humidity (55 + 20) RH
Test Method Specification
Sample condition Operating ( Continuous execute Power ONI OFF )
Temperature -40 DC
Dmation 24 Horus
bull Examine the appearance of specimen(s) by visual check and perfonn fimctional check after this test
bull Functional check Connect the specimen w ith rated power and PC via RS232 Execute diatmostic software
Boot_DVT then examine whether the Booting fimction Power ONOFF of specimen could be work nonnally or not
The Boot_DVT performs sequence as below
1 Power on the UUT
2 Wait for UUT booting into DOS and send out a text message via RS232
3 Once the text message is received and confumed as correct the Boot_DVT records a successful booting process
and power off the UUT
4 Wait for couple minutes to make sure the UUT is cool dowll
5 Repeat stepl
Unless oIIIelWise stated the results shown tIlis test repoot reler onIyO the samples) tested and such sal11lle(s) am Rlti ined lor 90 days only This test report CdflIlOI be 1eIgtfOduced exCE$llIn fuji without prior written pessIon of tile Company 1tj~imsttII ~fIittr 1i1Il~1I bulltZJilgtU fit~jj-l~lHI 90 7lt bull lttitdl0 ilJ iIilJfiiJ This doc-nent is issued by the Company subject to itS GOOerlIICOridliiOOS of SeMce plinted overJeat available on request or accesSible at T~ ond amp~ and lor electronic fOlllld dOClnlOnts subjectO Tenns ond Conditions lor Electrunic Documents at ~~ccmenns ~htm AIIenIlon is dra III IIle IimltlbOll 0 emrii jOrjSdidion issues defiled tIlerein Ally hoIdelt of tIlis documenI is advised that infonn~ iIid hiiriiln~ COfnpanys tndlOgS at tile ume 01 its rterventJon only anti MlIWl the limits of Clients instJUcIions W any The Companys sole responsibolity is to lis Client and IhIs documeot does not exanera1e pIIties to a ITansacl10n from exercising al lheir lights and obIgatiOns ~def the transactJon doclHlerlts This docunent camot be reproduced excep in rull wiIlIout pIior written 0IPPf0Yd1 of he Comp~ Ally UIlalIhoized a_ lorgelY or Ial8lfication of IhI 00fIIIf1t or appearance of tIlis document is unlaWlul and oIIeoders may be prosecuted to he Miesl extent of he 1aIII
~31 Na33No35 0Iy0m Raad Now IrWtisI Pak NJIu DiIbI NewTaipIi CiyTaioaIIMll1iftlUt1l 11111 31 It 33 35 ItINo134 WU ~ Rood New Taipei IIdSria Ptlt WUw Disht NewTaipei Cly Taiai~bull La1lHln IiLLJI 134 It
~ lt~tflmiddot-itafSHf fl~ ~ 1(8862) 2299-3279 r B86-~) 229~9558 -lWsuscom MemberfSGS Group
TEST REPORT Reliability Laboratory RepOli No HC5026412014
Page 3 of 4
Specimen
Style Item No Nuvo-3100VTC-I5DC No1
Quantity Total 1 set
Test Resultmiddot
~m Style Item No
Appearance check (visual check)
Functional check
Nuvo-3100VTC-ISDC No 1 No visible damage Normal
TEST REPORT Rel iability Laboratory RepOItNo HC5026412014
Page 4 of 4
Test Photos
1 Appearance of specimen
4 Functional check
The End of Test Report
TEST REPORT Reliabi lity Laboratory RepOli No HC5026412014
Page 2 of 4
1 Low Temperature Test
Test Equipment
Namr Brand Model SeliaJ No
Programmable Temperamre amp Humidity Chamber KSON TIIS-C6T- lSO+LN2 A0129
Lab Environmental Conditions
Ambient temperature ( 25 + 3) DC
Ambient humidity (55 + 20) RH
Test Method Specification
Sample condition Operating ( Continuous execute Power ONI OFF )
Temperature -40 DC
Dmation 24 Horus
bull Examine the appearance of specimen(s) by visual check and perfonn fimctional check after this test
bull Functional check Connect the specimen w ith rated power and PC via RS232 Execute diatmostic software
Boot_DVT then examine whether the Booting fimction Power ONOFF of specimen could be work nonnally or not
The Boot_DVT performs sequence as below
1 Power on the UUT
2 Wait for UUT booting into DOS and send out a text message via RS232
3 Once the text message is received and confumed as correct the Boot_DVT records a successful booting process
and power off the UUT
4 Wait for couple minutes to make sure the UUT is cool dowll
5 Repeat stepl
Unless oIIIelWise stated the results shown tIlis test repoot reler onIyO the samples) tested and such sal11lle(s) am Rlti ined lor 90 days only This test report CdflIlOI be 1eIgtfOduced exCE$llIn fuji without prior written pessIon of tile Company 1tj~imsttII ~fIittr 1i1Il~1I bulltZJilgtU fit~jj-l~lHI 90 7lt bull lttitdl0 ilJ iIilJfiiJ This doc-nent is issued by the Company subject to itS GOOerlIICOridliiOOS of SeMce plinted overJeat available on request or accesSible at T~ ond amp~ and lor electronic fOlllld dOClnlOnts subjectO Tenns ond Conditions lor Electrunic Documents at ~~ccmenns ~htm AIIenIlon is dra III IIle IimltlbOll 0 emrii jOrjSdidion issues defiled tIlerein Ally hoIdelt of tIlis documenI is advised that infonn~ iIid hiiriiln~ COfnpanys tndlOgS at tile ume 01 its rterventJon only anti MlIWl the limits of Clients instJUcIions W any The Companys sole responsibolity is to lis Client and IhIs documeot does not exanera1e pIIties to a ITansacl10n from exercising al lheir lights and obIgatiOns ~def the transactJon doclHlerlts This docunent camot be reproduced excep in rull wiIlIout pIior written 0IPPf0Yd1 of he Comp~ Ally UIlalIhoized a_ lorgelY or Ial8lfication of IhI 00fIIIf1t or appearance of tIlis document is unlaWlul and oIIeoders may be prosecuted to he Miesl extent of he 1aIII
~31 Na33No35 0Iy0m Raad Now IrWtisI Pak NJIu DiIbI NewTaipIi CiyTaioaIIMll1iftlUt1l 11111 31 It 33 35 ItINo134 WU ~ Rood New Taipei IIdSria Ptlt WUw Disht NewTaipei Cly Taiai~bull La1lHln IiLLJI 134 It
~ lt~tflmiddot-itafSHf fl~ ~ 1(8862) 2299-3279 r B86-~) 229~9558 -lWsuscom MemberfSGS Group
TEST REPORT Reliability Laboratory RepOli No HC5026412014
Page 3 of 4
Specimen
Style Item No Nuvo-3100VTC-I5DC No1
Quantity Total 1 set
Test Resultmiddot
~m Style Item No
Appearance check (visual check)
Functional check
Nuvo-3100VTC-ISDC No 1 No visible damage Normal
TEST REPORT Rel iability Laboratory RepOItNo HC5026412014
Page 4 of 4
Test Photos
1 Appearance of specimen
4 Functional check
The End of Test Report
TEST REPORT Reliability Laboratory RepOli No HC5026412014
Page 3 of 4
Specimen
Style Item No Nuvo-3100VTC-I5DC No1
Quantity Total 1 set
Test Resultmiddot
~m Style Item No
Appearance check (visual check)
Functional check
Nuvo-3100VTC-ISDC No 1 No visible damage Normal
TEST REPORT Rel iability Laboratory RepOItNo HC5026412014
Page 4 of 4
Test Photos
1 Appearance of specimen
4 Functional check
The End of Test Report
TEST REPORT Rel iability Laboratory RepOItNo HC5026412014
Page 4 of 4
Test Photos
1 Appearance of specimen
4 Functional check