UL VS Limited Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK
Telephone: +44 (0)1256 312000
Facsimile: +44 (0)1256 312001
TEST REPORT Test Report No. : UL-EMC-RP93552JD02A
Manufacturer : Vent-Axia Ltd
Type of Equipment : Extractor Fan
Model No. : Response
Test Standard : EN 55014-1:2006+A1:2009 Incorporating corrigendum January 2009, EN 55014-2:1997 + A2:2008 Incorporating corrigenda December 1997 and July 2007, EN 61000-3-2:2006 + A2:2009 and EN 61000-3-3:2008
Test Result : Complied
1. This report may not be reproduced other than in full, except with the prior written approval of UL VS Limited.
2. The results in this report apply only to the sample tested. 3. This sample tested is in compliance with the above standard(s). 4. The test results in this report are traceable to the national or international standards.
Date of issue: 05 July 2013 Checked by:
Gareth Bragg WiSE Laboratory Engineer
Issued by :
John Newell Group Quality Manager, WiSE
Basingstoke, UL Verification Services
Report Serial No: UL-EMC-RP93552JD02A
Page 2 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
This page has been left intentionally blank.
Report Serial No: UL-EMC-RP93552JD02A
Page 3 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
TABLE OF CONTENTS
1. Customer Details .............................................................................................................. 5 2. Summary of Testing ......................................................................................................... 6 3. Equipment under Test (EUT) ........................................................................................... 8 4. Support Equipment ........................................................................................................... 9 5. Monitoring Performance ................................................................................................ 10 6. Measurement Uncertainty .............................................................................................. 11 7. Measurements, Examinations and Derived Results .................................................... 12 8. Photographs of EUT ....................................................................................................... 34 9. Graphical Test Results ................................................................................................... 39 10. Test Configuration Drawing ......................................................................................... 47 11. Report Revision History ............................................................................................... 51
Report Serial No: UL-EMC-RP93552JD02A
Page 4 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
This page has been intentionally left blank.
Report Serial No: UL-EMC-RP93552JD02A
Page 5 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
1. CUSTOMER DETAILS
Company Name: Vent-Axia Ltd
Address: Fleming Way Crawley West Sussex RH10 9YX United Kingdom
Report Serial No: UL-EMC-RP93552JD02A
Page 6 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
2. SUMMARY OF TESTING
2.1. Test Specification Reference: EN 55014-1:2006+A1:2009 Incorporating corrigendum January 2009
Title: Electromagnetic compatibility - Requirements for house hold appliances, electric tools and similar apparatus - Part 1:Emission
Reference: EN 55014-2:1997 + A2:2008 Incorporating corrigenda December 1997 and July 2007
Title: Electromagnetic compatibility - Requirements for house hold appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard
Reference: EN 61000-3-2:2006 + A2:2009
Title: Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
Reference: EN 61000-3-3:2008
Title: Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
Comments: In accordance with requirements from the customer, tests were only performed in stated operating modes. Refer to the test result sheets for exact details of each mode performed.
2.2. Summary of Test Results Measurement Type Applicability Result
EMISSIONS
Radiated Emissions (Enclosure) No1 -
Conducted Emissions (AC Mains Input/Output Ports) Yes2
Disturbance Power (AC Mains Input/Output Ports) Yes2
Disturbance Power (Interconnecting Line) No3 -
Harmonic Current Emissions (AC Mains Input Port) Yes
Voltage Fluctuation and Flicker (AC Mains Input Port) Yes
IMMUNITY
Radiated Immunity No4 -
Conducted RF Immunity (AC Mains Input Port) Yes
Conducted RF Immunity (Interconnecting Lines) No3 -
Surges (AC Mains Input Port) Yes
Electrostatic Discharges Yes
Electrical Fast Transients Yes
Voltage Dips and Interruptions Yes
Notes 1. This test was not required for this product in accordance with the conditions set in EN 55014-1:2006+A1:2009
Incorporating corrigendum January 2009, Subclause 4.1.2.3.2 2. See Section 2.4, ‘Deviations from the Test Specification’ 3. Not applicable. The EUT has no interconnecting cables. 4. EUT is a Category II device and therefore this test is not required (in accordance with EN 55014-2:1997 + A2:2008
Incorporating corrigenda December 1997 and July 2007 , Clause 7.2.2)
KEY: = Complied = Complied, within uncertainty = Did not comply, within uncertainty = Did not comply
2.3. Location of Testing All the measurements described in this report were performed at the premises of UL VS Limited, Unit 3 Horizon, Wade Road, Kingsland Business Park, Basingstoke, Hampshire RG24 8AH.
Report Serial No: UL-EMC-RP93552JD02A
Page 7 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
2.4. Deviations from the Test Specification a). Conducted Emissions and Disturbance Power measurements were not made at the spot frequencies set out in sub-clauses7.4.1.3 and 7.4.1.4 of EN 55014-1:2006+A1:2009 Incorporating corrigendum January 2009. This was at the customers` request, due to the EUT`s emissions being generally low across the relevant spectrum
b). For Conducted Emissions and Disturbance Power measurements, the tests at 160 kHz and 50 MHz were not performed over the range of 0.9 to 1.1 times the rated voltage as set out in sub-clause 7.1.4 of EN 55014-1:2006+A1:2009 Incorporating corrigendum January 2009. This was at the customers` request.
c). In accordance with a request from the customer, Disturbance Power measurements were made at a fixed point on the cable being tested. This was not more than 3 metres from the EUT. In the event that emissions were less than 10 bBpW from the specification limit, the full cable length was tested to maximise the emissions.
Report Serial No: UL-EMC-RP93552JD02A
Page 8 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
3. EQUIPMENT UNDER TEST (EUT)
3.1. Description of EUT
The EUT was a residential ventilation fan
3.2. Identification of Equipment under Test (EUT) ID# Description Brand Name Model No Stock Reference
1 Fan Vent Axia Ltd Response None Stated
3.3. Port Identification Port Description Possible Length (m) Type Connector 1 Enclosure - - -
2 AC Mains > 3 AC Power Input 3-core
3.4. Operating Modes Mode Reference Definition
15 Litres p/s The EUT was set to operate at its maximum speed setting
9 Litres p/s The EUT was set to operate at its medium speed setting
6 Litres p/s The EUT was set to operate at its minimum speed setting
3.5. Configuration and Peripherals Description: Please refer to the Test Configuration and Photograph section for schematic
drawing(s) and/or photograph(s) of the test configuration(s) employed in the course of testing.
3.6. Modifications NOTE: No modifications were made to the EUT during the course of testing.
3.7. Additional Information Related to Testing Equipment Category: II
Intended Operating Environment: Residential / Commercial
Intended Installation: Wall Mounted
Double Insulated equipment: No
Cycle Time: < 1 s
Power Supply Requirement(s): 230 VAC, 50 Hz
Power Rating of Equipment: 6 W
Handheld equipment: Yes / No
Weight: 0.6 kg
Dimensions: 190 x 190 x 130 mm
Hardware Version Number: None Stated
Report Serial No: UL-EMC-RP93552JD02A
Page 9 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
4. SUPPORT EQUIPMENT
4.1. Identification of Support Equipment NOTE: No support equipment was used during the course of testing.
4.2. Interconnecting Cables NOTE: No interconnecting cables were used during the course of testing.
Report Serial No: UL-EMC-RP93552JD02A
Page 10 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
5. MONITORING PERFORMANCE
5.1. Overview
A functional description and a definition of performance criteria, during or as a consequence of the EMC testing, shall be provided by the manufacturer and noted in the test report, based on the following criteria. Performance criteria were not applicable for emissions tests.
5.2. Performance Criteria Criterion A The apparatus shall continue to operate as intended during the test. No degradation of performance or loss of
function is allowed below a performance level (or permissible loss of performance) specified by the manufacturer, when the apparatus is used as intended. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, then either of these may be derived from the product description and documentation, and from what the user may reasonably expect from the apparatus if used as intended.
Criterion B The apparatus shall continue to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level (or permissible loss of performance) specified by the manufacturer, when the apparatus is used as intended. During the test, degradation of performance is allowed, however, no change of actual operating state or stored data is allowed. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, then either of these may be derived from the product description and documentation, and from what the user may reasonably expect from the apparatus if used as intended.
Criterion C Temporary loss of function is allowed, provided the function is self-recoverable or can be restored by the operation of the controls, or by any operation specified in the instructions for use.
5.3. Monitoring EUT Performance during Testing For the purposes of testing, the term “operate as intended” was defined as:
The EUT continued to operate at the set speed.
For the purposes of testing, an “unintentional response” was defined as:
An applied EMC phenomenon causing the EUT speed setting to change.
Method used to determine whether user control functions and stored data were lost after the EMC exposure:
A functionality check was performed after each exposure
Method of assessment of level of performance or degradation of performance during and/or after EMC exposure:
The EUT was monitored for airflow changes
Report Serial No: UL-EMC-RP93552JD02A
Page 11 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
6. MEASUREMENT UNCERTAINTY
6.1. Overview
No measurement or test can ever be perfect and the imperfections give rise to error of measurement in the results. Consequently, the result of a measurement is only an approximation to the value of the measurand (the specific quantity subject to measurement) and is only complete when accompanied by a statement regarding the uncertainty of approximation.
The measurement uncertainty may need to be taken into account when interpreting the test results included within this test report.
6.2. Method of calculation
The methods used to calculate the uncertainties included within this test report are in line with those recommended within the various measurement specifications. Where measurement specifications do not include guidelines for the evaluation of measurement uncertainty, the published guidance of the United Kingdom Accreditation Service (UKAS) is followed.
Report Serial No: UL-EMC-RP93552JD02A
Page 12 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
7. MEASUREMENTS, EXAMINATIONS AND DERIVED RESULTS
7.1. General Comments
7.1.1. This section contains the test result sheets for the measurements listed in Section 2.2. Summary of Test Results (above).
7.1.2. The measurement uncertainties stated in the test result sheets were calculated in accordance with documented best practice and represent a confidence level of 95%. Where only confidence level is given, it has been demonstrated that the relevant items of test equipment used meet the specified requirements in the standard with at least this level of confidence.
7.1.3. Please refer to Section 6. Measurement Uncertainty on page 11 for details of our treatment of measurement uncertainty.
Report Serial No: UL-EMC-RP93552JD02A
Page 13 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
CONDUCTED EMISSIONS - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: 2005.
GENERAL INFORMATION JOB NUMBER: 93552JD02 TEST SITE ID: Site 8
EUT: Response TEMPERATURE: 23 °C to 23 °C
TEST ENGINEER: Gareth Bragg RELATIVE HUMIDITY: 34 % to 34 %
DATE OF TEST: 04 Apr 2013 ATMOSPHERIC PRESSURE: 995 mb to 995 mb
UNCERTAINTY: ± 4.69 dB EQUIPMENT CLASS: Not Applicable
CATEGORY: AC Mains (Household Appliances) MEASUREMENT METHOD: LISN (AC)
TEST SPECIFICATION DETAILS
The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard:
REFERENCE: EN 55014-1:2006+A1:2009 Incorporating corrigendum January 2009
TITLE: Electromagnetic compatibility - Requirements for house hold appliances, electric tools and similar apparatus - Part 1:Emission
COMMENTS
None
DEVIATIONS FROM TEST SPECIFICATION
a). Measurements were not made at the spot frequencies set out in sub-clauses7.4.1.3 of EN 55014-1:2006+A1:2009 Incorporating corrigendum January 2009. This was at the customers` request, due to the EUT`s emissions being generally low across the relevant spectrum. b). The test at 160 kHz was not performed over the range of 0.9 to 1.1 times the rated voltage as set out in sub-clause 7.1.4 of EN 55014-1:2006+A1:2009 Incorporating corrigendum January 2009. This was at the customers` request.
EUT RELATED OPERATING MODE: 15 Litres p/s
FUNCTION(S) MONITORED:
Not Applicable
MEASUREMENT RESULTS
No. Frequency (MHz) Line Detector Level
(dBµV) Limit
(dBµV) Margin
(dB) Graph No. Result
1 0.150 Neutral Quasi-Peak 45.6 66.0 20.4 001 Complied 2 0.263 Neutral Quasi-Peak 45.8 61.4 15.5 001 Complied 3 0.398 Neutral Quasi-Peak 39.3 57.9 18.6 001 Complied 4 0.794 Neutral Quasi-Peak 35.5 56.0 20.5 001 Complied 5 1.968 Live 1 Quasi-Peak 31.1 56.0 24.9 001 Complied 6 5.829 Neutral Quasi-Peak 24.3 60.0 35.7 001 Complied 7 23.055 Live 1 Quasi-Peak 15.5 60.0 44.5 001 Complied 8 0.177 Neutral Average (CISPR) 34.3 57.2 22.9 001 Complied 9 0.267 Neutral Average (CISPR) 34.6 52.8 18.1 001 Complied
10 0.398 Neutral Average (CISPR) 30.4 48.5 18.0 001 Complied 11 0.789 Neutral Average (CISPR) 24.3 46.0 21.7 001 Complied 12 1.964 Neutral Average (CISPR) 21.4 46.0 24.6 001 Complied 13 5.424 Neutral Average (CISPR) 16.8 50.0 33.2 001 Complied 14 23.276 Live 1 Average (CISPR) 10.5 50.0 39.5 001 Complied
Report Serial No: UL-EMC-RP93552JD02A
Page 14 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
NOTES 1 Pre-scans were completed in the following modes of operation: 15 Litres p/s, 9 Litres p/s and 6 Litres p/s From these pre-
scans, the worst case mode was determined to be 15 Litres p/s and final measurements were completed in this mode only.
TEST EQUIPMENT USED
UL ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL M1263 EMI Test Receiver ESIB7 09 Aug 2013 12 M1623 Thermometer Hygrometer Station 30.5015.13 09 Jan 2014 12 K0008 Conducted Emissions / RF immunity Laboratory N/A Calibration not required N/A C455 3m Flexy Cable RG142XX-001-RFIB 21 Feb 2014 12 A004 Single phase LISN ESH3-Z5 30 Oct 2013 12 C455 3m Flexy Cable RG142XX-001-RFIB 21 Feb 2014 12 A1830 Pulse Limiter ESH3-Z2 19 Feb 2014 12
Report Serial No: UL-EMC-RP93552JD02A
Page 15 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
HARMONIC CURRENT EMISSIONS - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: 2005.
GENERAL INFORMATION JOB NUMBER: 93552JD02 TEST SITE ID: Site 6
EUT: Response TEMPERATURE: 23 °C to 23 °C
TEST ENGINEER: Gareth Bragg RELATIVE HUMIDITY: 38 % to 38 %
DATE OF TEST: 04 Apr 2013 ATMOSPHERIC PRESSURE: 1012 mb to 1012 mb
UNCERTAINTY: ± 5.82 % EQUIPMENT CLASS: Class A
THC (A): 0.05 POHC (A): 0.000
I-THD (%): 119.84 POHC LIMIT (A): 0.251
TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard:
REFERENCE: EN 61000-3-2:2006 + A2:2009
TITLE: Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
COMMENTS
None
DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above).
EUT RELATED
OPERATING MODE: 15 Litres p/s
FUNCTION(S) MONITORED: Not Applicable
CURRENT AND VOLTAGE WAVEFORMS
-0.3-0.2-0.10.00.10.20.3
-300-200-1000100200300
Curre
nt (A
mps
)Voltage (Volts)
Report Serial No: UL-EMC-RP93552JD02A
Page 16 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
HARMONICS AND CLASS A LIMIT LINE (EUROPEAN LIMITS)
0.00.51.01.52.02.53.03.5
Cur
rent
RM
S(A
mps
)
Harmonic #4 8 12 16 20 24 28 32 36 40
HIGHEST PARAMETER VALUES DURING TEST V_RMS (V): 229.56 FREQUENCY (Hz): 50
I_PEAK (A): 0.266 I_RMS (A): 0.063
I_FUND (A): 0.039 CREST FACTOR: 4.408
POWER (W): 6 POWER FACTOR: 0.429
MEASUREMENT RESULTS
Harm Harms (Avg) 100% Limit % of Limit Harms (Max) 150% Limit % of Limit Result
2 0.001 1.08 0.1 0.001 1.620 0.08 Complied 3 0.025 2.30 1.1 0.026 3.450 0.77 Complied 4 0.001 0.43 0.2 0.001 0.645 0.14 Complied 5 0.022 1.14 2.0 0.023 1.710 1.35 Complied 6 0.000 0.30 0.1 0.001 0.450 0.12 Complied 7 0.019 0.77 2.5 0.020 1.155 1.71 Complied 8 0.000 0.23 0.1 0.000 0.345 0.10 Complied 9 0.016 0.40 3.9 0.016 0.600 2.67 Complied 10 0.000 0.18 0.1 0.000 0.276 0.15 Complied 11 0.012 0.33 3.7 0.012 0.495 2.49 Complied 12 0.000 0.15 0.2 0.000 0.230 0.20 Complied 13 0.009 0.21 4.3 0.009 0.315 2.92 Complied 14 0.000 0.13 0.2 0.000 0.197 0.21 Complied 15 0.007 0.15 4.5 0.007 0.225 3.05 Complied 16 0.000 0.12 0.2 0.000 0.173 0.26 Complied 17 0.006 0.13 4.2 0.006 0.199 2.88 Complied 18 0.000 0.10 0.3 0.000 0.153 0.29 Complied 19 0.005 0.12 4.4 0.005 0.178 3.02 Complied 20 0.000 0.09 0.3 0.000 0.138 0.31 Complied 21 0.005 0.11 4.8 0.005 0.161 3.29 Complied 22 0.000 0.08 0.3 0.000 0.125 0.31 Complied 23 0.005 0.10 5.0 0.005 0.147 3.40 Complied 24 0.000 0.08 0.3 0.000 0.115 0.31 Complied 25 0.004 0.09 4.9 0.005 0.135 3.36 Complied 26 0.000 0.07 0.3 0.000 0.106 0.29 Complied 27 0.004 0.08 4.5 0.004 0.125 3.12 Complied 28 0.000 0.07 0.3 0.000 0.099 0.31 Complied 29 0.003 0.08 4.1 0.003 0.116 2.87 Complied
Report Serial No: UL-EMC-RP93552JD02A
Page 17 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
MEASUREMENT RESULTS
Harm Harms (Avg) 100% Limit % of Limit Harms (Max) 150% Limit % of Limit Result
30 0.000 0.06 0.3 0.000 0.092 0.31 Complied 31 0.003 0.07 4.0 0.003 0.109 2.73 Complied 32 0.000 0.06 0.3 0.000 0.086 0.34 Complied 33 0.003 0.07 4.0 0.003 0.102 2.80 Complied 34 0.000 0.05 0.4 0.000 0.081 0.36 Complied 35 0.003 0.06 4.2 0.003 0.096 2.92 Complied 36 0.000 0.05 0.4 0.000 0.077 0.34 Complied 37 0.003 0.06 4.3 0.003 0.091 2.97 Complied 38 0.000 0.05 0.4 0.000 0.073 0.36 Complied 39 0.002 0.06 4.2 0.002 0.087 2.85 Complied 40 0.000 0.05 0.4 0.000 0.069 0.35 Complied
NOTES 1 During measurement the engineer did not record any specific notes relevant to report.
TEST EQUIPMENT USED
UL ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVALK0006 Electrostatic Discharge and Fast Transient Laboratory N/A Calibration not required N/A M1623 Thermometer Hygrometer Station 30.5015.13 09 Jan 2014 12 M524 300V 4800VA 1ph Harmonics/Flicker Test system 6843A 19 Jul 2013 12 M1188 Signal Conditioning Unit - Lumped Impedance CCN 1000-1 18 Jul 2013 12 M517 Series II Digital Multimeter JF77 Series 20 Aug 2013 12
Report Serial No: UL-EMC-RP93552JD02A
Page 18 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
DISTURBANCE POWER - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: 2005.
GENERAL INFORMATION JOB NUMBER: 93552JD02 TEST SITE ID: Site 8
EUT: Response TEMPERATURE: 25 °C to 25 °C
TEST ENGINEER: Gareth Bragg RELATIVE HUMIDITY: 39 % to 39 %
DATE OF TEST: 25 May 2013 ATMOSPHERIC PRESSURE: 1021 mb to 1021 mb
MEASUREMENT UNITS: dBpW MEASUREMENT DISTANCE: Not applicable
UNCERTAINTY: ± 5.62 dB EQUIPMENT CLASS: Household
TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN 55014-1:2006+A1:2009 Incorporating corrigendum January 2009
TITLE: Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
COMMENTS None
DEVIATIONS FROM TEST SPECIFICATION a) Measurements were not made at the spot frequencies set out in sub-clause 7.4.1.4 of EN 55014-1:2006+A1:2009 Incorporating corrigendum January 2009. This was at the customers` request, due to the EUT`s emissions being generally low across the relevant spectrum. b). The test at 50 MHz was not performed over the range of 0.9 to 1.1 times the rated voltage as set out in sub-clause 7.1.4 of EN 55014-1:2006+A1:2009 Incorporating corrigendum January 2009. This was at the customers` request. c). In accordance with a request from the customer, measurements were made at a fixed point on the cable being tested. This was not more than 3 metres from the EUT. In the event that emissions were less than 10 dBpW from the specification limit, the full cable length was tested to maximise the emissions.
EUT RELATED OPERATING MODE: 15 Litres p/s
FUNCTION(S) MONITORED:
Not Applicable
MEASUREMENT RESULTS
No. Frequency (MHz) Line Detector Level
(dBpW) Limit
(dBpW) Margin
(dB) Graph No. Result
1 56.8449 AC Mains Quasi-Peak 23.4 47.8 24.3 005 Complied2 76.2036 AC Mains Quasi-Peak 27.2 49.0 21.9 005 Complied3 84.0745 AC Mains Quasi-Peak 29.8 49.5 19.6 005 Complied4 108.8441 AC Mains Quasi-Peak 27.4 50.6 23.2 005 Complied5 168.9259 AC Mains Quasi-Peak 28.3 52.5 24.2 005 Complied6 197.2232 AC Mains Quasi-Peak 26.5 53.2 26.7 005 Complied7 218.5972 AC Mains Quasi-Peak 15.6 53.6 38.0 005 Complied8 272.7439 AC Mains Quasi-Peak 19.4 54.6 35.2 005 Complied9 56.6910 AC Mains Average (CISPR) 6.6 37.8 31.2 005 Complied
10 85.0100 AC Mains Average (CISPR) 12.8 39.5 26.7 005 Complied11 95.8798 AC Mains Average (CISPR) 13.5 40.0 26.5 005 Complied12 115.7748 AC Mains Average (CISPR) 20.5 40.9 20.3 005 Complied13 168.5820 AC Mains Average (CISPR) 14.8 42.5 27.7 005 Complied14 197.0597 AC Mains Average (CISPR) 13.0 43.2 30.2 005 Complied15 222.2621 AC Mains Average (CISPR) 9.0 43.7 34.7 005 Complied16 273.7539 AC Mains Average (CISPR) 8.9 44.6 35.7 005 Complied
Report Serial No: UL-EMC-RP93552JD02A
Page 19 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
NOTES 1 During measurement the engineer did not record any specific notes relevant to report.
TEST EQUIPMENT USED
UL ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVALK0008 Conducted Emissions / RF immunity Laboratory N/A Calibration not required N/A M1263 EMI Test Receiver ESIB7 09 Aug 2013 12 C455 3m Flexy Cable RG142XX-001-RFIB 21 Feb 2014 12 M1625 Thermometer Hygrometer Station 30.5015.06 09 Jan 2014 12 A004 Single phase LISN ESH3-Z5 30 Oct 2013 12
Report Serial No: UL-EMC-RP93552JD02A
Page 20 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
DISTURBANCE POWER - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: 2005.
GENERAL INFORMATION JOB NUMBER: 93552JD02 TEST SITE ID: Site 8
EUT: Response TEMPERATURE: 25 °C to 25 °C
TEST ENGINEER: Gareth Bragg RELATIVE HUMIDITY: 39 % to 39 %
DATE OF TEST: 25 May 2013 ATMOSPHERIC PRESSURE: 1021 mb to 1021 mb
MEASUREMENT UNITS: dBpW MEASUREMENT DISTANCE: Not applicable
UNCERTAINTY: ± 5.62 dB EQUIPMENT CLASS: Household
TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN 55014-1:2006+A1:2009 Incorporating corrigendum January 2009
TITLE: Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
COMMENTS None
DEVIATIONS FROM TEST SPECIFICATION a) .Measurements were not made at the spot frequencies set out in sub-clause 7.4.1.4 of EN 55014-1:2006+A1:2009 Incorporating corrigendum January 2009. This was at the customers` request, due to the EUT`s emissions being generally low across the relevant spectrum. b). The test at 50 MHz was not performed over the range of 0.9 to 1.1 times the rated voltage as set out in sub-clause 7.1.4 of EN 55014-1:2006+A1:2009 Incorporating corrigendum January 2009. This was at the customers` request. c). In accordance with a request from the customer, measurements were made at a fixed point on the cable being tested. This was not more than 3 metres from the EUT. In the event that emissions were less than 10 dBpW from the specification limit, the full cable length was tested to maximise the emissions.
EUT RELATED OPERATING MODE: 6 Litres p/s
FUNCTION(S) MONITORED:
Not Applicable
MEASUREMENT RESULTS
No. Frequency (MHz) Line Detector Level
(dBpW) Limit
(dBpW) Margin
(dB) Graph No. Result
1 59.9038 AC Mains Quasi-Peak 24.0 48.0 24.0 006 Complied2 115.0341 AC Mains Quasi-Peak 29.2 50.8 21.6 006 Complied3 137.3291 AC Mains Quasi-Peak 22.0 51.6 29.6 006 Complied4 169.5703 AC Mains Quasi-Peak 28.9 52.5 23.6 006 Complied5 221.4637 AC Mains Quasi-Peak 23.4 53.7 30.3 006 Complied6 269.5311 AC Mains Quasi-Peak 18.5 54.5 36.0 006 Complied7 60.0000 AC Mains Average (CISPR) 10.0 38.0 28.0 006 Complied8 116.5275 AC Mains Average (CISPR) 19.5 40.9 21.4 006 Complied9 140.9699 AC Mains Average (CISPR) 9.1 41.7 32.6 006 Complied
10 170.5010 AC Mains Average (CISPR) 18.4 42.5 24.1 006 Complied11 217.9623 AC Mains Average (CISPR) 3.3 43.6 40.3 006 Complied12 284.6236 AC Mains Average (CISPR) 6.8 44.8 38.0 006 Complied
NOTES 1 During measurement the engineer did not record any specific notes relevant to report.
Report Serial No: UL-EMC-RP93552JD02A
Page 21 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
TEST EQUIPMENT USED
UL ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVALK0008 Conducted Emissions / RF immunity Laboratory N/A Calibration not required N/A M1263 EMI Test Receiver ESIB7 09 Aug 2013 12 C455 3m Flexy Cable RG142XX-001-RFIB 21 Feb 2014 12 M1625 Thermometer Hygrometer Station 30.5015.06 09 Jan 2014 12 A004 Single phase LISN ESH3-Z5 30 Oct 2013 12
Report Serial No: UL-EMC-RP93552JD02A
Page 22 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
DISTURBANCE POWER - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: 2005.
GENERAL INFORMATION JOB NUMBER: 93552JD02 TEST SITE ID: Site 8
EUT: Response TEMPERATURE: 25 °C to 25 °C
TEST ENGINEER: Gareth Bragg RELATIVE HUMIDITY: 39 % to 39 %
DATE OF TEST: 25 May 2013 ATMOSPHERIC PRESSURE: 1021 mb to 1021 mb
MEASUREMENT UNITS: dBpW MEASUREMENT DISTANCE: Not applicable
UNCERTAINTY: ± 5.62 dB EQUIPMENT CLASS: Household
TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN 55014-1:2006+A1:2009 Incorporating corrigendum January 2009
TITLE: Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
COMMENTS None
DEVIATIONS FROM TEST SPECIFICATION a) .Measurements were not made at the spot frequencies set out in sub-clause 7.4.1.4 of EN 55014-1:2006+A1:2009 Incorporating corrigendum January 2009. This was at the customers` request, due to the EUT`s emissions being generally low across the relevant spectrum. b). The test at 50 MHz was not performed over the range of 0.9 to 1.1 times the rated voltage as set out in sub-clause 7.1.4 of EN 55014-1:2006+A1:2009 Incorporating corrigendum January 2009. This was at the customers` request. c). In accordance with a request from the customer, measurements were made at a fixed point on the cable being tested. This was not more than 3 metres from the EUT. In the event that emissions were less than 10 dBpW from the specification limit, the full cable length was tested to maximise the emissions.
EUT RELATED OPERATING MODE: 9 Litres p/s
FUNCTION(S) MONITORED:
Not Applicable
MEASUREMENT RESULTS
No. Frequency (MHz) Line Detector Level
(dBpW) Limit
(dBpW) Margin
(dB) Graph No. Result
1 56.7391 AC Mains Quasi-Peak 23.1 47.8 24.6 007 Complied2 114.8705 AC Mains Quasi-Peak 16.9 50.8 33.9 007 Complied3 169.4261 AC Mains Quasi-Peak 19.6 52.5 32.9 007 Complied4 200.0417 AC Mains Quasi-Peak 17.6 53.2 35.7 007 Complied5 241.9527 AC Mains Quasi-Peak 14.9 54.1 39.2 007 Complied6 297.6434 AC Mains Quasi-Peak 15.3 55.0 39.6 007 Complied7 56.8713 AC Mains Average (CISPR) 6.9 37.8 30.8 007 Complied8 95.9928 AC Mains Average (CISPR) 21.6 40.1 18.5 007 Complied9 114.8345 AC Mains Average (CISPR) 5.5 40.8 35.3 007 Complied
10 140.9483 AC Mains Average (CISPR) 6.9 41.7 34.8 007 Complied11 168.0481 AC Mains Average (CISPR) 7.0 42.5 35.5 007 Complied12 198.5218 AC Mains Average (CISPR) 5.9 43.2 37.3 007 Complied13 286.5090 AC Mains Average (CISPR) 4.7 44.8 40.1 007 Complied
Report Serial No: UL-EMC-RP93552JD02A
Page 23 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
NOTES 1 During measurement the engineer did not record any specific notes relevant to report.
TEST EQUIPMENT USED
UL ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVALK0008 Conducted Emissions / RF immunity Laboratory N/A Calibration not required N/A M1263 EMI Test Receiver ESIB7 09 Aug 2013 12 C455 3m Flexy Cable RG142XX-001-RFIB 21 Feb 2014 12 M1625 Thermometer Hygrometer Station 30.5015.06 09 Jan 2014 12 A004 Single phase LISN ESH3-Z5 30 Oct 2013 12
Report Serial No: UL-EMC-RP93552JD02A
Page 24 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
VOLTAGE FLUCTUATIONS AND FLICKER – TEST RESULTS This test is covered by the scope of RFI’s UKAS Accreditation under ISO/IEC 17025: 2005.
GENERAL INFORMATION JOB NUMBER: 93552JD02 TEST SITE ID: Site 6
EUT: Response TEMPERATURE: 23 °C to 23 °C
TEST ENGINEER: Gareth Bragg RELATIVE HUMIDITY: 38 % to 38 %
DATE OF TEST: 04 Apr 2013 ATMOSPHERIC PRESSURE: 1012 mb to 1012 mb
UNCERTAINTY: ± 5.92 % Plt Limit: 0.65
VOLTAGE: 240 V Pst Limit: 1
FREQUENCY: 50 Hz
TEST SPECIFICATION DETAILS
The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard:
REFERENCE: EN 61000-3-3: 2008 TITLE: Electromagnetic compatibility (EMC) – Part 3: Limits – Section 3: Limitation of voltage changes, voltage
fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
COMMENTS
None
DEVIATIONS FROM TEST SPECIFICATION
There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above).
EUT RELATED OPERATING MODE: 15 Litres p/s
FUNCTION(S) MONITORED: Not Applicable
Pst AND LIMIT LINE
0.1100.1150.1200.1250.1300.135
Pst
21:36:04
Report Serial No: UL-EMC-RP93552JD02A
Page 25 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
Plt AND LIMIT LINE
0.0500
0.0525
0.0550
0.0575Plt
21:36:04
PARAMETER VALUES RECORDED DURING TEST Vrms at the end of the test (V): 229.55
Highest dt (%) 0.00 Test Limit (%): 3.30 Complied
Time (ms) > dt: 0.0 Test Limit (ms): 500.0 Complied
Highest dc (%): 0.00 Test Limit (%): 3.30 Complied
Highest dmax (%): 0.00 Test Limit (%): 4.00 Complied
NOTES 1 During measurement the engineer did not record any specific notes relevant to report.
TEST EQUIPMENT USED
UL ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVALK0006 Electrostatic Discharge and Fast Transient Laboratory N/A Calibration not required N/A M524 300V 4800VA 1ph Harmonics/Flicker Test system 6843A 19 Jul 2013 12 M1188 Signal Conditioning Unit - Lumped Impedance CCN 1000-1 18 Jul 2013 12 M1623 Thermometer Hygrometer Station 30.5015.13 09 Jan 2014 12 M517 Series II Digital Multimeter JF77 Series 20 Aug 2013 12
Report Serial No: UL-EMC-RP93552JD02A
Page 26 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
ELECTROSTATIC DISCHARGE - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: 2005.
GENERAL INFORMATION JOB NUMBER: 93352JD02 TEST SITE ID: Site 6
EUT: Response TEMPERATURE: 21 °C to 21 °C
TEST ENGINEER: Graeme Morris RELATIVE HUMIDITY: 36 % to 36 %
DATE OF TEST: 09 Apr 2013 ATMOSPHERIC PRESSURE: 996 mb to 996 mb
UNCERTAINTY: 95% confidence level AIR CONTACT LIMIT: 8 kV
PERFORMANCE CRITERIA: Criterion B DIRECT CONTACT LIMIT: 4 kV
TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN 61000-4-2: 1995 including Amendment A1: 1998 and Amendment A2: 2001
TITLE: Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
COMMENTS None
DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above).
EUT RELATED OPERATING MODE: 15 Litres p/s
FUNCTION(S) MONITORED: The EUT was monitored for air flow changes.
DIRECT CONTACT TO EUT
Refer to Note 1
AIR GAP TO EUT Test Points No. Attempted Test Voltage (kV) Notes Result A to H 10 ± 8.0 2 Complied
POSITION TO OBJECT IN VICINITY OF EUT (HORIZONTAL COUPLING PLANE) Test Points No. Attempted Test Voltage (kV) Notes Result Front, Left, Rear, Right 10 ± 4.0 3 Complied
POSITION TO OBJECT IN VICINITY OF EUT (VERTICAL COUPLING PLANE) Test Points No. Attempted Test Voltage (kV) Notes Result Front, Left, Rear, Right 10 ± 4.0 3 Complied
NOTE(S)
1 Due to the all-plastic construction of the EUT, contact discharges were not applicable.
2 Air gap discharges were attempted at this point, but due to the build of the EUT, discharges were not achieved.
3 During measurement the engineer did not record any specific notes relevant to report.
Report Serial No: UL-EMC-RP93552JD02A
Page 27 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
TEST EQUIPMENT USED
UL ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL K0006 Electrostatic Discharge and Fast Transient Laboratory N/A Calibration not required N/A G090 ESD Simulator NSG 435 29 Aug 2013 12 A1420 Vertical Coupling Plane N/A Calibration not required N/A A1935 Discharge Carbon Brush N/A Calibration not required N/A A1934 Discharge Network N/A Calibration not required N/A M1623 Thermometer Hygrometer Station 30.5015.13 09 Jan 2014 12
Report Serial No: UL-EMC-RP93552JD02A
Page 28 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
FAST TRANSIENTS - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: 2005.
GENERAL INFORMATION JOB NUMBER: 93552JD02 TEST SITE ID: Site 6
EUT: Response TEMPERATURE: 21 °C to 21 °C
TEST ENGINEER: Graeme Morris RELATIVE HUMIDITY: 35 % to 36 %
DATE OF TEST: 09 Apr 2013 ATMOSPHERIC PRESSURE: 998 mb to 998 mb
UNCERTAINTY: 95% confidence level LEVEL: ± 1.0 kV
PERFORMANCE CRITERIA: Criterion B BURST PERIOD: 300 ms
REPETITION RATE: 5.0 kHz BURST DURATION: 15 ms
PULSE RISE TIME: 5 ns PULSE DURATION 50 ns
TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN 61000-4-4: 2004
TITLE: Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
COMMENTS None
DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above).
EUT RELATED OPERATING MODE: 15 Litres p/s
FUNCTION(S) MONITORED: The EUT was monitored for airflow changes.
TEST RESULTS Port Line Under Test Test Voltage (kV) Notes Result AC Mains Live ± 0.5 1 Complied AC Mains Neutral ± 0.5 1 Complied AC Mains Live and Neutral ± 0.5 1 Complied AC Mains Live ± 1.0 1 Complied AC Mains Neutral ± 1.0 1 Complied AC Mains Live and Neutral ± 1.0 1 Complied Switch Line Switch Line ± 0.25 1 Complied Switch Line Switch Line ± 0.5 1 Complied Switch Line Switch Line ± 1.0 1 Complied
NOTES 1 During measurement the engineer did not record any specific notes relevant to report.
TEST EQUIPMENT USED
UL ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL K0006 Electrostatic Discharge and Fast Transient Laboratory N/A Calibration not required N/A M1141 Immunity Test System Transient 2000 28 Sep 2013 12 M1623 Thermometer Hygrometer Station 30.5015.13 09 Jan 2014 12
Report Serial No: UL-EMC-RP93552JD02A
Page 29 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
CONDUCTED IMMUNITY - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: 2005.
GENERAL INFORMATION JOB NUMBER: 93552JD02 TEST SITE ID: Site 8
EUT: Response TEMPERATURE: 23 °C to 23 °C
TEST ENGINEER: Gareth Bragg RELATIVE HUMIDITY: 34 % to 34 %
DATE OF TEST: 11 Apr 2013 ATMOSPHERIC PRESSURE: 997 mb to 997 mb
UNCERTAINTY: ± 3.86 dB DWELL TIME: 1.5 s
PERFORMANCE CRITERIA: Criterion A FREQUENCY RANGE: 0.15 to 230 MHz
LEVEL: 3 Vrms SWEEP RATE: 2.881x10-3 decades/s
STEP SIZE: 1% log of momentary frequency MODULATION: 80% AM @ 1 kHz
TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN 61000-4-6: 2009
TITLE: Electromagnetic compatibility (EMC) Part 4-6: Testing and measurement techniques - Immunity disturbances, induced by radio-frequency fields
COMMENTS
The list of actual test frequencies used during these measurements is available on request.
DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above).
EUT RELATED OPERATING MODE: 15 Litres p/s
FUNCTION(S) MONITORED: The EUT was monitored for airflow changes
MEASUREMENT RESULTS
No. Line Under Test Coupling Method Frequency Band Spot Frequency Level Notes Result
1 AC Mains Input CDN 0.15 to 230 MHz - 3 Vrms 1 Complied
NOTES 1 During measurement the engineer did not record any specific notes relevant to report.
Report Serial No: UL-EMC-RP93552JD02A
Page 30 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
TEST EQUIPMENT USED
UL ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVALK0008 Conducted Emissions / RF immunity Laboratory N/A Calibration not required N/A G009 Signal Generator 10 kHz to 1 GHz SMG Calibrated as part of system N/A M1164 Power Meter 10kHz - 2GHz CPW 9670 Calibrated as part of system N/A N0545 Site 8 PC with Schaffner C3 Immunity software 450 Calibration not required N/A C1265 2m N-Type Coaxial Cable FA210A1020007070 Calibrated as part of system N/A A1163 Attenuator 6dB 53-6-34 Calibrated before use N/A A1931 High Pass Filter 2.2 to 12GHz AFH-02000 27 Jan 2014 12 C1091 Cable 293-3362 Calibrated as part of system N/A C301 Cable UFA 210A-1-0590-50x50 Calibrated as part of system N/A C1093 Cable 293-3362 Calibrated as part of system N/A C356 Cable (was C537) UFA210A-1-1181-70x70 Calibrated as part of system N/A A1291 DC3400 Directional Coupler DC3400 Calibrated before use N/A A1025 50 Ohm Terminator 612-192 Calibrated before use N/A A531 100 ohm calibration unit N/A Calibrated before use N/A A530 100 ohm calibration unit N/A Calibrated before use N/A A1325 CDN Calibration Kit 1 Calibrated before use N/A C1071 RF Cable FA21A1030M5050 Calibrated as part of system N/A C1088 5m Cable FA210A1050005050 19 Feb 2014 12 M1625 Thermometer Hygrometer Station 30.5015.06 09 Jan 2014 12
Report Serial No: UL-EMC-RP93552JD02A
Page 31 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
VOLTAGE DIPS AND INTERRUPTIONS - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: 2005.
GENERAL INFORMATION JOB NUMBER: 93552JD02 TEST SITE ID: Site 6
EUT: Response TEMPERATURE: 21 °C to 21 °C
TEST ENGINEER: Graeme Morris RELATIVE HUMIDITY: 35 % to 35 %
DATE OF TEST: 09 Apr 2013 ATMOSPHERIC PRESSURE: 996 mb to 996 mb
UNCERTAINTY: 95% confidence level PERFORMANCE CRITERIA: Criterion C
NOMINAL VOLTAGE: 240 V POWER SUPPLY TYPE: AC Mains
TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN 61000-4-11: 2004
TITLE: Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
COMMENTS None
DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above).
EUT RELATED OPERATING MODE: 15 Litres p/s
FUNCTION(S) MONITORED: The EUT was monitored for airflow changes
MEASUREMENT RESULTS
No. Line Under Test
Phenomena Type
Reduction (%)
Performance Criteria
Increase (%)
Test Voltage (V)
Period of Reduction /
Increase Result
1 AC Mains Dip 100 Criterion C - 0 10 Complied 2 AC Mains Dip 60 Criterion C - 96 200 Complied 3 AC Mains Dip 30 Criterion C - 168 500 Complied
NOTES 1 During measurement the engineer did not record any specific notes relevant to report.
TEST EQUIPMENT USED
UL ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL K0006 Electrostatic Discharge and Fast Transient Laboratory N/A Calibration not required N/A M1623 Thermometer Hygrometer Station 30.5015.13 09 Jan 2014 12 M1141 Immunity Test System Transient 2000 28 Sep 2013 12
Report Serial No: UL-EMC-RP93552JD02A
Page 32 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
SURGE TRANSIENTS - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: 2005.
GENERAL INFORMATION JOB NUMBER: 93552JD02 TEST SITE ID: Site 7
EUT: Response TEMPERATURE: 23 °C to 23 °C
TEST ENGINEER: Gareth Bragg RELATIVE HUMIDITY: 34 % to 34 %
DATE OF TEST: 04 Apr 2013 ATMOSPHERIC PRESSURE: 995 mb to 995 mb
UNCERTAINTY: 95% confidence level PERFORMANCE CRITERIA: Criterion B
LIMIT - DIFF. MODE: ± 1.0 kV LIMIT - COMMON MODE: ± 2.0 kV
GEN IMP - DIFF MODE: 2 Ω GEN IMP - COMMON MODE: 12 Ω
PULSE RISE TIME: 1.2 µs PULSE DURATION: 50 µs
PRIMARY PROTECTION: Not stated SECONDARY PROTECTION: Not stated
REPETITION TIME: 20 s
TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN 61000-4-5: 2006
TITLE: Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
COMMENTS
None
DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above).
EUT RELATED OPERATING MODE: 15 Litres p/s
FUNCTION(S) MONITORED: The EUT was monitored for airflow changes
MEASUREMENT RESULTS
No. Line Description Mode Line Under Test Test Voltage (kV) Phase Angle Result
1 AC Mains Input Differential Live to Neutral ± 1.0 0°, 90°, 180°, 270° Complied 2 AC Mains Input Common Live to Earth ± 2.0 0°, 90°, 180°, 270° Complied 3 AC Mains Input Common Neutral to Earth ± 2.0 0°, 90°, 180°, 270° Complied
NOTES 1 During measurement the engineer did not record any specific notes relevant to report.
Report Serial No: UL-EMC-RP93552JD02A
Page 33 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
TEST EQUIPMENT USED
UL ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL A274 3 Phase Surge CDN CDN 113 25 Mar 2014 12 G039 NSG 651 Pulse Generator NSG 651 25 Mar 2014 12 K0007 Surges Test Laboratory N/A Calibration not required N/A M1624 Thermometer Hygrometer Station 30.5015.10 09 Jan 2014 12 M517 Series II Digital Multimeter JF77 Series 20 Aug 2013 12
Report Serial No: UL-EMC-RP93552JD02A
Page 34 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
8. PHOTOGRAPHS OF EUT
This section contains the following photographs:
Photo Reference Number Title
PHT\93552JD02\001 Test Configuration Photograph – EFT and VDI
PHT\93552JD02\003 Test Configuration photograph – Surge
PHT\93552JD02\003 Test Configuration Photograph – Conducted Emissions
PHT\93552JD02\004 Test Configuration Photograph – Disturbance Power
Report Serial No: UL-EMC-RP93552JD02A
Page 35 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
PHT\93552JD02\001 - Test Configuration Photograph – EFT and VDI
Report Serial No: UL-EMC-RP93552JD02A
Page 36 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
PHT\93552JD02\002 - Test Configuration Photograph – Surge
Report Serial No: UL-EMC-RP93552JD02A
Page 37 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
PHT\93552JD02\003 - Test Configuration Photograph – Conducted Emissions
Report Serial No: UL-EMC-RP93552JD02A
Page 38 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
PHT\93552JD02\004 - Test Configuration Photograph – Disturbance Power
Report Serial No: UL-EMC-RP93552JD02A
Page 39 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
9. GRAPHICAL TEST RESULTS
9.1. This section contains the graphical results for the measurements listed in Section 2.2. Summary of Test Results (above).
Graph Reference Number Title
GPH\93552JD02\001 Conducted Emissions – 15 Litres p/s Final Measurements ( 0.15 kHz to 30 MHz )
GPH\93552JD02\002 Conducted Emissions – 15 Litres p/s Pre-Scan ( 0.15 kHz to 30 MHz )
GPH\93552JD02\003 Conducted Emissions – 9 Litres p/s Pre-Scan ( 0.15 kHz to 30 MHz )
GPH\93552JD02\004 Conducted Emissions – 6 Litres p/s Pre-Scan ( 0.15 kHz to 30 MHz )
GPH\93552JD02\005 Disturbance Power – 15 Litres p/s Final Measurements ( 30 MHz to 300 MHz )
GPH\93552JD02\006 Disturbance Power – 6 Litres p/s Final Measurements ( 30 MHz to 300 MHz )
GPH\93552JD02\007 Disturbance Power – 9 Litres p/s Final Measurements ( 30 MHz to 300 MHz )
Report Serial No: UL-EMC-RP93552JD02A
Page 40 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
GPH\93552JD02\001
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
150k 300 400 500 800 1M 2M 3M 4M 5M 6 8 10M 20M 30M
Leve
l in
dBµV
Frequency in Hz
EN55014 Voltage with 2-Line-LISN - No Spots
EN 55014 Voltage on Mains QP
EN 55014 Voltage on Mains AV
Report Serial No: UL-EMC-RP93552JD02A
Page 41 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
GPH\93552JD02\002
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
150k 300 400 500 800 1M 2M 3M 4M 5M 6 8 10M 20M 30M
Leve
l in
dBµV
Frequency in Hz
EN55014 Voltage with 2-Line-LISN - No Spots
EN 55014 Voltage on Mains QP
EN 55014 Voltage on Mains AV
Report Serial No: UL-EMC-RP93552JD02A
Page 42 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
GPH\93552JD02\003
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
150k 300 400 500 800 1M 2M 3M 4M 5M 6 8 10M 20M 30M
Leve
l in
dBµV
Frequency in Hz
EN55014 Voltage with 2-Line-LISN - No Spots
EN 55014 Voltage on Mains QP
EN 55014 Voltage on Mains AV
Report Serial No: UL-EMC-RP93552JD02A
Page 43 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
GPH\93552JD02\004
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
150k 300 400 500 800 1M 2M 3M 4M 5M 6 8 10M 20M 30M
Leve
l in
dBµV
Frequency in Hz
EN55014 Voltage with 2-Line-LISN - No Spots
EN 55014 Voltage on Mains QP
EN 55014 Voltage on Mains AV
Report Serial No: UL-EMC-RP93552JD02A
Page 44 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
GPH\93552JD02\005
0
5
10
15
20
25
30
35
40
45
50
55
60
30 50 100 150 200 250 300
Leve
l in
dBpW
Frequency in MHz
EN55014 Interference Power with MDS Clamp
EN 55014 Power QP
EN 55014 Power AV
Report Serial No: UL-EMC-RP93552JD02A
Page 45 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
GPH\93552JD02\006
0
5
10
15
20
25
30
35
40
45
50
55
60
30 50 100 150 200 250 300
Leve
l in
dBpW
Frequency in MHz
EN55014 Interference Power with MDS Clamp
EN 55014 Power QP
EN 55014 Power AV
Report Serial No: UL-EMC-RP93552JD02A
Page 46 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
GPH\93552JD02\007
0
5
10
15
20
25
30
35
40
45
50
55
60
30 50 100 150 200 250 300
Leve
l in
dBpW
Frequency in MHz
EN55014 Interference Power with MDS Clamp
EN 55014 Power QP
EN 55014 Power AV
Report Serial No: UL-EMC-RP93552JD02A
Page 47 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
10. TEST CONFIGURATION DRAWING
10.1. This section contains the Test Configuration Drawings for the measurements listed in Section 7: Measurements, Examinations and Derived Results.
Test Configuration Reference Number Title
DRG\93552JD02\001 ESD Test Point Photograph - Test Points A and B
DRG\93552JD02\002 ESD Test Point Photograph - Test Points C to H
DRG\93552JD02\003 Schematic diagram of the EUT, support equipment and interconnecting cables used for the test
Report Serial No: UL-EMC-RP93552JD02A
Page 48 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
DRG\93552JD02\001 - ESD Test Point Photograph - Test Points A and B
Report Serial No: UL-EMC-RP93552JD02A
Page 49 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
DRG\93552JD02\002 - ESD Test Point Photograph - Test Points C to H
Report Serial No: UL-EMC-RP93552JD02A
Page 50 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
DRG\93552JD02\003 - Schematic diagram of the EUT, support equipment and interconnecting cables used for the test
Report Serial No: UL-EMC-RP93552JD02A
Page 51 of 51
Issue date: 05 JULY 2013
UL VS Limited, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK, Telephone: +44 (0)1256 312000 , Facsimile: +44 (0)1256 312001
11. REPORT REVISION HISTORY
11.1. This section contains the report revision history.
Version Number
Revision Details
Page No(s) Clause Details
1.0 - - Initial Version.