TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN ...agmultivision.net/risorse/utilita_disegni...

16
TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: 081-100118-101 7F., No.37, Sec. 2, Zhongyang S., Rd., EX77y-A1M1 .DOC Beitou District, Taipei City, 11270, Taiwan. Page 1 of 14 Test Report IECEN60950_1C Test Report issued under the responsibility of: NCB TÜV SÜD PSB Pte Ltd 1 Science Park Drive, Singapore 118221 TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment – Safety – Part 1: General requirements Report Reference No. .....................: 081-100118-101 Date of issue..................................... : 2011-02-21 Total number of pages....................... 14 CB/CCA Testing Laboratory ..........: TÜV SÜD Asia Ltd. Taiwan Branch Address............................................. : 7F., No.37, Sec. 2, Zhongyang S., Rd., Beitou District, Taipei City, 11270, Taiwan. Applicant’s name ............................: Delta Electronics, Inc. Address............................................. : No. 3, Tung Yuan Rd., Chungli Ind. Zone, Taoyuan Hsien, Taiwan. Manufacturer’s name .....................: Delta Electronics, Inc. Address............................................. : No. 3, Tung Yuan Rd., Chungli Ind. Zone, Taoyuan Hsien, Taiwan. Factory’s name ...............................: See page 5 for details. Address............................................. : See page 5 for details. Test specification: Standard ........................................... : IEC 60950-1:2005 (2nd Edition) and/or EN 60950-1:2006 + A11:2009 Test procedure ................................. : CB / CCA Non-standard test method…………..: N/A Test Report Form No. .....................: IECEN60950_1C Test Report Form(s) Originator ........ : SGS Fimko Ltd Master TRF ....................................... : Dated 2007-06 Copyright © 2007 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. If this Test Report Form is used by non-CCA members, the CIG logo and the reference to the CCA Procedure shall be removed. This report is not valid as a CCA Test Report unless signed by an approved CCA Testing Laboratory and appended to a CCA Test Certificate issued by an NCB in accordance with CCA

Transcript of TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN ...agmultivision.net/risorse/utilita_disegni...

Page 1: TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN ...agmultivision.net/risorse/utilita_disegni tecnici... · Test Report IECEN60950_1C Summary of testing: Tests performed (name

TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: 081-100118-101 7F., No.37, Sec. 2, Zhongyang S., Rd., EX77y-A1M1 .DOC Beitou District, Taipei City, 11270, Taiwan. Page 1 of 14

Test Report IECEN60950_1C

Test Report issued under the responsibility of: NCB TÜV SÜD PSB Pte Ltd 1 Science Park Drive, Singapore 118221

TEST REPORT

IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment – Safety –

Part 1: General requirementsReport Reference No. ..................... : 081-100118-101

Date of issue ..................................... : 2011-02-21

Total number of pages ....................... 14

CB/CCA Testing Laboratory .......... : TÜV SÜD Asia Ltd. Taiwan Branch

Address............................................. : 7F., No.37, Sec. 2, Zhongyang S., Rd., Beitou District, Taipei City, 11270, Taiwan.

Applicant’s name ............................ : Delta Electronics, Inc.

Address............................................. : No. 3, Tung Yuan Rd., Chungli Ind. Zone, Taoyuan Hsien, Taiwan.

Manufacturer’s name ..................... : Delta Electronics, Inc.

Address............................................. : No. 3, Tung Yuan Rd., Chungli Ind. Zone, Taoyuan Hsien, Taiwan.

Factory’s name ............................... : See page 5 for details.

Address............................................. : See page 5 for details.

Test specification:

Standard ........................................... : IEC 60950-1:2005 (2nd Edition) and/or EN 60950-1:2006 + A11:2009

Test procedure ................................. : CB / CCA

Non-standard test method…………..: N/A

Test Report Form No. ..................... : IECEN60950_1C

Test Report Form(s) Originator ........ : SGS Fimko Ltd

Master TRF ....................................... : Dated 2007-06

Copyright © 2007 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved.

This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context.

If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. If this Test Report Form is used by non-CCA members, the CIG logo and the reference to the CCA Procedure shall be removed. This report is not valid as a CCA Test Report unless signed by an approved CCA Testing Laboratory and appended to a CCA Test Certificate issued by an NCB in accordance with CCA

Page 2: TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN ...agmultivision.net/risorse/utilita_disegni tecnici... · Test Report IECEN60950_1C Summary of testing: Tests performed (name

TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: 081-100118-101 7F., No.37, Sec. 2, Zhongyang S., Rd., EX77y-A1M1 .DOC Beitou District, Taipei City, 11270, Taiwan. Page 2 of 14

Test Report IECEN60950_1C

Test item description ..................... : DLP Projector

Trade Mark ........................................ : 1. Optoma

2. InFocus

Manufacturer ..................................... : Same as applicant

Model/Type reference ....................... : 1. EH106y, DAEXTyy, DAEHGyyy, DAEHNyyy, EH206y,

EX78yy, EX77yy

2. SP86y0

(“y” can be any character or blank)

Ratings .............................................. : 100-240 Vac, 50/60 Hz, 3.5 A or 4.2 A (when 300W lamp is used)

Testing procedure and testing location:

CB/CCA Testing Laboratory: TÜV SÜD Asia Ltd. Taiwan Branch

Testing location/ address ...................... : 7F., No.37, Sec. 2, Zhongyang S., Rd., Beitou District, Taipei City, 11270, Taiwan.

Associated CB Laboratory: N/A

Testing location/ address ...................... : N/A

Tested by

(name + signature) ...................... : Mr. Larry Lai

.....................................................

Approved by

(+ signature) ................................ : Mr. Watson Yang

..................................................... Testing procedure: TMP N/A

Tested by (name + signature) ..... :

Approved by (+ signature) ............ :

Testing location/ address ...................... : N/A

Testing procedure: WMT N/A

Tested by (name + signature) ..... :

Witnessed by (+ signature) .......... :

Approved by (+ signature) ........... :

Testing location/ address ...................... : N/A

Testing procedure: SMT N/A

Tested by (name + signature) ..... :

Approved by (+ signature) ............ :

Supervised by (+ signature) ........ :

Testing location/ address ................ : N/A

Testing procedure: RMT N/A

Tested by (name + signature) ..... :

Approved by (+ signature) ............ :

Supervised by (+ signature) ........ :

Testing location/ address ...................... : N/A

Page 3: TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN ...agmultivision.net/risorse/utilita_disegni tecnici... · Test Report IECEN60950_1C Summary of testing: Tests performed (name

TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: 081-100118-101 7F., No.37, Sec. 2, Zhongyang S., Rd., EX77y-A1M1 .DOC Beitou District, Taipei City, 11270, Taiwan. Page 3 of 14

Test Report IECEN60950_1C

Summary of testing:

Tests performed (name of test and test clause):

All test results were found satisfactory in accordance with IEC 60950-1:2005(2nd Edition) and / EN 60950-1: 2006 + A11:2009.

Testing location:

All tests as described in Test Case and Measurement Sections were performed at the laboratory described on page 2.

Summary of compliance with National Differences:

National Differences for Austria (AT), Canada (CA), Germany (DE), Denmark (DK), Finland (FI), France

(FR), United Kingdom (GB), Italy (IT), Japan (JP), Korea (KR), The Netherlands (NL), Norway (NO),

Poland (PL), Sweden (SE), Slovenia (SI), United States of America (US). Group Differences as listed in the

CB Bulletin No. 112A (December 2006) are recorded at the end of this report.

Copy of marking plate

See attachment No. 2 of Test Report Ref. No.: 081-100118-000 and attachment No. 1 of Test Report Ref. No.: 081-100118-001 and attachment No. 1 of Test Report Ref. No.: 081-100118-101

Page 4: TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN ...agmultivision.net/risorse/utilita_disegni tecnici... · Test Report IECEN60950_1C Summary of testing: Tests performed (name

TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: 081-100118-101 7F., No.37, Sec. 2, Zhongyang S., Rd., EX77y-A1M1 .DOC Beitou District, Taipei City, 11270, Taiwan. Page 4 of 14

Test Report IECEN60950_1C

Test item particulars .................................................. :

Equipment mobility .................................................... : [Χ] movable [] hand-held [] transportable [] stationary [] for building-in [] direct plug-in

Connection to the mains ............................................ : [Χ] pluggable equipment [Χ] type A [] type B [] permanent connection [Χ] detachable power supply cord [] non-detachable power supply cord [] not directly connected to the mains

Operating condition ................................................... : [Χ] continuous [] rated operating / resting time:

Access location ......................................................... : [Χ] operator accessible [] restricted access location

Over voltage category (OVC) ................................... : [] OVC I [Χ] OVC II [] OVC III [] OVC IV [] other:

Mains supply tolerance (%) or absolute mains supply values ....................................................................... :

+10%, -10%

Tested for IT power systems .................................... : [Χ] Yes [] No

IT testing, phase-phase voltage (V) ......................... : 230V (for Norway)

Class of equipment ................................................... : [Χ] Class I [] Class II [] Class III [] Not classified

Considered current rating (A) ................................... : 16A or 20A for US

Pollution degree (PD) ............................................... : [] PD 1 [Χ] PD 2 [] PD 3

IP protection class .................................................... : Ordinary

Altitude during operation (m) .................................... : Up to 2000

Altitude of test laboratory (m) ................................... : Below 2000

Mass of equipment (kg) ............................................ : Approx. 3.3

Possible test case verdicts:

- test case does not apply to the test object ................. : N/A

- test object does meet the requirement ....................... : P (Pass)

- test object does not meet the requirement ................. : F (Fail)

Testing .......................................................................... :

Date of receipt of test item ............................................ : 2011-02-11

Date(s) of performance of tests .................................... : 2011-02-11 to 2011-02-16

Page 5: TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN ...agmultivision.net/risorse/utilita_disegni tecnici... · Test Report IECEN60950_1C Summary of testing: Tests performed (name

TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: 081-100118-101 7F., No.37, Sec. 2, Zhongyang S., Rd., EX77y-A1M1 .DOC Beitou District, Taipei City, 11270, Taiwan. Page 5 of 14

Test Report IECEN60950_1C

General remarks:

The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report.

Note: This TRF includes EN Group Differences together with National Differences and Special National Conditions, if any. All Differences are located in the Appendix to the main body of this TRF.

Throughout this report a point is used as the decimal separator.

Factory:

Delta Video Display System (Wujiang) Limited ( ID No.: 45855)

1688, JiangXing E.Rd., WuJiang Economic, 215200 Development Zone, WuJiang City,

JiangSu, People's Republic of China

Attachments:

Original Test Report No. 081-100118-000 78 pages + 38 pages attachments

Additional Test Report No. 081-100118-001 7 pages + 1 page attachments

Attachment No. 1 Marking Plate 1 page

Attachment No. 2 Photo 1 page

Report No. < 081-100118-101>

The construction of the DLP Projector models EX77y, EH106y, DAEXTyy and DAEHGyyy were modified as follows:

1. Add new models DAEHNyyy, EH206y, EX78yy, EX77yy and delete model EX77y.

2. Add input current ratings 4.2 A when 300W lamp is used.

3. Alternate component for Lamp, Ballast, Fuse and revise manufacturer of Enclosure see table 1.5.1 for details.

For the above described modification the following Clause/Testing was considered to be necessary:

S/N Clause/Testing Remark/Comments Verdict

1. Clause 1.7 Marking and instructions P

2. Table 1.5.1 List of critical components P

3. Table 1.6.2 electrical data (in normal conditions) P

4. Table 4.5 Thermal requirements P

5. Table 5.2 Electric strength measurements P

6. Table 5.3 Fault condition tests P

Page 6: TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN ...agmultivision.net/risorse/utilita_disegni tecnici... · Test Report IECEN60950_1C Summary of testing: Tests performed (name

TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: 081-100118-101 7F., No.37, Sec. 2, Zhongyang S., Rd., EX77y-A1M1 .DOC Beitou District, Taipei City, 11270, Taiwan. Page 6 of 14

Test Report IECEN60950_1C

General product information:

The equipment is a DLP Projector of information technology equipment.

In models EH106y, DAEXTyy, DAEHGyyy, DAEHNyyy, EH206y, EX78yy, EX77yy and SP86y0, where “y” can be any character or blank to denote different client ID.

All models are identical except for model designation and trademark.

The maximum ambient temperature specified by manufacturer is 40 oC.

Unless otherwise indicated, all tests are performed on model EX77 to represent other similar models.

Page 7: TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN ...agmultivision.net/risorse/utilita_disegni tecnici... · Test Report IECEN60950_1C Summary of testing: Tests performed (name

IEC/EN 60950-1

Clause Requirement + Test Result - Remark Verdict

TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: 081-100118-101 7F., No.37, Sec. 2, Zhongyang S., Rd., EX77y-A1M1 .DOC Beitou District, Taipei City, 11270, Taiwan. Page 7 of 14

Test Report IECEN60950_1C

1.7 Marking and instructions P

1.7.1 Power rating See below. P

Rated voltage(s) or voltage range(s) (V) ............... : 100-240 Vac P

Symbol for nature of supply, for d.c. only ............... : Mains from AC source. N/A

Rated frequency or rated frequency range (Hz) ... : 50/60 Hz P

Rated current (mA or A) ........................................ : 3.5 A or 4.2 A (when 300W lamp is used)

P

Manufacturer’s name or trade-mark or identification mark ................................................. :

1. Optoma

2. InFocus

P

Model identification or type reference ................... : 1. EH106y, DAEXTyy, DAEHGyyy, DAEHNyyy, EH206y, EX78yy, EX77yy

2. SP86y0

(“y” can be any character or blank)

P

Symbol for Class II equipment only ...................... : Class I equipment. N/A

Other markings and symbols ................................ : Additional symbols or markings that do not give rise to misunderstand.

P

Page 8: TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN ...agmultivision.net/risorse/utilita_disegni tecnici... · Test Report IECEN60950_1C Summary of testing: Tests performed (name

TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: 081-100118-101 7F., No.37, Sec. 2, Zhongyang S., Rd., EX77y-A1M1 .DOC Beitou District, Taipei City, 11270, Taiwan. Page 8 of 14

Test Report IECEN60950_1C

1.5.1 TABLE: List of critical components P

Object/part No. Manufacturer/ trademark

Type/model Technical data Standard (Edition / year)

Mark(s) of conformity1)

Alternate Component

Lamp (Alternate) Philips UHP 300-250W 1.1 E21.7

Ignition voltage 7.5 kV max., 300W

-- --

Ballast (Alternate)

Philips EUC 300e B/F11 I/P: 280-415 Vdc, 1300m A, O/P:200~330 W

EN60950-1:2006 KEMA

Fuse (F101) (alternate) only for 300W lamp

Littelfuse 215 T6.3AH, 250V EN/IEC 60127-1, EN/IEC 60127-2

UL, VDE

Fuse (F101) (alternate) only for 300W lamp

Bel 5HT T6.3AH, 250V EN/IEC 60127-1, EN/IEC 60127-2

UL, VDE

Revised Component

Enclosure Styron Celex 3600 HP 5V, 125 °C, min. 2.5mm thick.

UL 94, UL 746C

UL

Enclosure (back IO cover and keypad cover)

Styron Celex 3600 HP 5V, 125 °C, min. 2.5mm thick.

UL 94, UL 746C

UL

1) an asterisk indicates a mark which assures the agreed level of surveillance

Page 9: TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN ...agmultivision.net/risorse/utilita_disegni tecnici... · Test Report IECEN60950_1C Summary of testing: Tests performed (name

TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: 081-100118-101 7F., No.37, Sec. 2, Zhongyang S., Rd., EX77y-A1M1 .DOC Beitou District, Taipei City, 11270, Taiwan. Page 9 of 14

Test Report IECEN60950_1C

1.6.2 TABLE: electrical data (in normal conditions) P

U (Vac/Hz) I (A) Irated (A) P (W) Fuse # Ifuse (A) Condition/status

With VGA input, audio out and 12V trigger

(Test with Lamp: Philips type: UHP 300-250W 1.1 E21.7 and Ballast, Philips type: EUC 300e B/F11 )

90/50 4.45 -- 395 F101 4.45 Maximum Normal load

90/60 4.45 -- 395 F101 4.45 Maximum Normal load

100/50 3.95 4.2 390 F101 3.95 Maximum Normal load

100/60 3.95 4.2 390 F101 3.95 Maximum Normal load

240/50 1.61 4.2 375 F101 1.61 Maximum Normal load

240/60 1.61 4.2 375 F101 1.61 Maximum Normal load

264/50 1.45 -- 372 F101 1.45 Maximum Normal load

264/60 1.45 -- 372 F101 1.45 Maximum Normal load

Page 10: TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN ...agmultivision.net/risorse/utilita_disegni tecnici... · Test Report IECEN60950_1C Summary of testing: Tests performed (name

TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: 081-100118-101 7F., No.37, Sec. 2, Zhongyang S., Rd., EX77y-A1M1 .DOC Beitou District, Taipei City, 11270, Taiwan. Page 10 of 14

Test Report IECEN60950_1C

4.5 TABLE: Thermal requirements P

Supply voltage (V) .......................... : See below. —

Ambient Tmin (C) ............................ : Ditto. —

Ambient Tmax (C) ............................ :

Maximum measured temperature T of part/at:

T (C) Allowed Tmax (C)

Test with Lamp: Philips type: UHP 300-250W 1.1 E21.7 and Ballast, Philips type: EUC 300e B/F11

Test condition Normal projection Ceiling projection --

90V 264V 90V 264V

01. T301 coil 75.5 63.5 75.6 64.8 110

02. T301 core 73.4 62.3 73.4 63.5 110

03. ISO101 69.8 54.7 69.5 55.8 100

04. ISO102 71.9 58.1 71.9 59.0 100

05. CY105 63.9 49.7 62.1 50.7 85

06. C106 57.8 47.8 58.1 59.4 85

07. CX103 52.2 42.2 51.9 43.7 85

08. CY103 44.7 41.2 45.0 42.6 85

09. TVR101 65.4 46.3 64.9 47.9 105

10. PCB under NTC101 42.4 70.5 56.6 48.2 105

11. CR101 100 58.2 95.9 58.8 105

12. FL101 70.2 43.8 67.6 45.4 120

13. FL102 57.8 44.4 66.6 46.0 120

14. D101 82.6 58.2 80.7 58.7 105

15. Q101 93.5 57.9 89.5 57.9 105

16. L102 109.9 61.5 107.8 63.1 120

17. D102 82.7 56.2 79.9 56.4 105

18. F101 52.4 42.3 52.7 43.8 105

19. L101 71.9 45.2 71.9 47.3 105

20. AC inlet 42.1 40.4 42.6 41.9 85

21. L20 (BALLAST) 71.4 69.9 71.6 70.6 105

22. L19(ballast) 75.8 73.0 75.4 73.6 105

Page 11: TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN ...agmultivision.net/risorse/utilita_disegni tecnici... · Test Report IECEN60950_1C Summary of testing: Tests performed (name

TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: 081-100118-101 7F., No.37, Sec. 2, Zhongyang S., Rd., EX77y-A1M1 .DOC Beitou District, Taipei City, 11270, Taiwan. Page 11 of 14

Test Report IECEN60950_1C

Maximum measured temperature T of part/at:

T (C) Allowed Tmax (C)

Test condition Normal projection Ceiling projection --

90V 264V 90V 264V --

23. L3 (BALLAST) 70.9 67.7 70.6 67.5 105

24. L6 (ballast) 74.8 73.8 73.4 72.4 105

25. Lamp Housing 97.4 97.3 97.1 97.8 200

26. Lamp Cover 57.4 57.2 60.3 60.6 105

27. Label’s Position 41.5 40.7 41.7 41.9 70

28. Video’s body 41.9 40.8 42.0 41.9 70

29. Vent. Openings 78.7 80.6 74.7 74.7 95

30. Ambient 40.0 40.0 40.0 40.0 --

Page 12: TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN ...agmultivision.net/risorse/utilita_disegni tecnici... · Test Report IECEN60950_1C Summary of testing: Tests performed (name

TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: 081-100118-101 7F., No.37, Sec. 2, Zhongyang S., Rd., EX77y-A1M1 .DOC Beitou District, Taipei City, 11270, Taiwan. Page 12 of 14

Test Report IECEN60950_1C

Temperature T of winding: t1 (°C) R1 () t2 (°C) R2 () T (C) Allowed Tmax (C)

Insulation class

-- -- -- -- -- -- -- --

-- -- -- -- -- -- -- --

-- -- -- -- -- -- -- --

Supplementary information:

The temperatures were measured by thermal couple (type K) method under worst case normal mode as described in 1.6.2 at voltage described in 1.4.5. The worst case normal mode is defined with max load of the equipment.

With max. ambient temperature specified as 40 C, therefore, the maximum temperature rise is calculated as follows:

Winding components:

- class B Max temp=120°C-10°C= 110°C

Components with:

- Max. temp. of 70°C(lnlet)

- Max. temp. of 85°C(X-cap,Y-cap and others capacitors)

- Max. temp. of 100°C(Opto-coupler)

- Max. temp. of 130°C (FL102, FL101, L102)

- Max. temp. of 105°C(PCB and L101)

- Max. temp. of 85°C(Ripple capacitor)

- Max. temp. of 70°C(plastic enclosure)

- Max. temp. of 200°C(Lamp holder)

- when no class of insulation is given, min. insulation 105C assumed.

User accessible area:

- material is plastic (95°C)

Page 13: TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN ...agmultivision.net/risorse/utilita_disegni tecnici... · Test Report IECEN60950_1C Summary of testing: Tests performed (name

TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: 081-100118-101 7F., No.37, Sec. 2, Zhongyang S., Rd., EX77y-A1M1 .DOC Beitou District, Taipei City, 11270, Taiwan. Page 13 of 14

Test Report IECEN60950_1C

5.2 TABLE: Electric strength measurements P

test voltage applied between: test voltage (V) breakdown

Primary-PE AC 2527V No

Primary-Secondary DC 4242V No

Page 14: TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN ...agmultivision.net/risorse/utilita_disegni tecnici... · Test Report IECEN60950_1C Summary of testing: Tests performed (name

TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: 081-100118-101 7F., No.37, Sec. 2, Zhongyang S., Rd., EX77y-A1M1 .DOC Beitou District, Taipei City, 11270, Taiwan. Page 14 of 14

Test Report IECEN60950_1C

5.3 TABLE: Fault condition tests P

Ambient temperature (C) ................................... : 25 oC or see below

Power source for EUT: Manufacturer, model/type, output rating ........................................................ :

See Table 1.5.1 for detail

Component No.

Fault Supply voltage (Vac)

Test time

Fuse # Fuse current

(A)

Observation

Test with Lamp: Philips type: UHP 300-250W 1.1 E21.7 and Ballast, Philips type: EUC 300e B/F11

Vent. Openings

Blocked 240 2H F101 0.14 No fire, No hazards. Max. temperature of T301 coil: 73.3 C; T301 core: 70.6 C; IC101: 64.4 C; IC102: 67.9 C; CY105: 67.7 C; ambient: 28.0 C.

Fan1 Blocked 240 2H F101 0.13 No fire, No hazards. Max. temperature of T301 coil: 70.0 C; T301 core: 65.9 C; IC101: 50.5 C; IC102: 55.8 C; CY105: 57.7 C; ambient: 24.2 C.

Fan 2 Stalled 240 0.25H F101 0.13 No fire, No hazard. The unit shutdown immediately.

Fan 3 Stalled 240 0.25H F101 0.13 No fire, No hazard. The unit shutdown immediately.

Fan 4 Stalled 240 0.25H F101 0.13 No fire, No hazard. The unit shutdown immediately.

Color Wheel Stalled 240 0.25H F101 0.13 No fire, No hazard. The unit shutdown immediately.

Q101 (D-G) SC 240 1S F101 0 Fuse open instantly, no damaged, no hazards.

Q101 (S-D) SC 240 1S F101 0 Fuse open instantly, no damaged, no hazards.

C105 SC 240 1S F101 0 Fuse open instantly, no damaged, no hazards.

CR101 (2-4) SC 240 1S F101 0 Fuse open instantly, no damaged, no hazards.

CR101 (3-4) SC 240 1S F101 0 Fuse open instantly, no damaged, no hazards.

IC101 (1-7) SC 240 1S F101 0 Fuse open instantly. ZD101 damaged, no hazards.

Note: For fuse opened conditions, same results came out for all sources of fuse. If fuse not open have repeat test three times.

Page 15: TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN ...agmultivision.net/risorse/utilita_disegni tecnici... · Test Report IECEN60950_1C Summary of testing: Tests performed (name

Attachment No. 1

Page 1 of 1

081-100118-101

Note. The marking label for model EX77yy is used as a representative label for other models. All labels are identical except for model designation.

The above labels are draft of artwork for marking plate pending approval by National Certification Bodies and they shall not be affixed to products prior to such an approval.

Page 16: TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN ...agmultivision.net/risorse/utilita_disegni tecnici... · Test Report IECEN60950_1C Summary of testing: Tests performed (name

Attachment No. 2

Page 1 of 1

Type Designation: EH106y, DAEXTyy, DAEHGyyy, DAEHNyyy, EH206y,

EX78yy, EX77yy, SP86y0

Report Number: 081-100118-101

Ballast: Philips, type: UHP 300-250W 1.1 E21.7

Lamp: Philips, type: EUC 300e B/F11