terase verzi

16
Bauder extensive planting – Low maintenance Green Roof System Pitched roof systems Green roof systems Flat roof systems

description

Terase verzi

Transcript of terase verzi

Page 1: terase verzi

Bauder extensive planting –Low maintenance Green Roof System

Pitched roof systems Green roof systems Flat roof systems

Page 2: terase verzi

Diversity for healthy growth

Contents

p. 3 ....................................... Extensiveplanting–morethanaprotectiveeco-layer Extensive planting using a multi-layer construction p 4 ....................................... Extensiveplantingtosuitindividualrequirements

p. 5 ....................................... Criteriaforselectingthesystem

p. 6 ....................................... BauderSDFmat–budgetdrainagesystem

p. 7 ....................................... BauderdrainageandstorageelementN20–drainagethat willwithstandpressure

p. 8 ....................................... Bauderwaterstoragepanel–thesophisticatedplantingmethod

p. 9 ....................................... Baudermineraldrain–coarsemineralparticles

Light green roof systemp. 10...................................... Extensiveplantingforroofconstructionswithreducedload bearingcapacity

p. 11...................................... Bauderwaterstoragepanelwithlightsubstrate–plantingsystemfor trapezoidalsheetroofs Extensive planting for single layer construction

p. 12...................................... Extensiveplantingforlargeroofareas

p. 13...................................... Bauderplantsubstrate–thebudgetsolution

Extensive system planting

p. 14...................................... Hydrosowing–BaudersprayplantingusingtheHämmerlemethod

p. 14...................................... PlantingwithBauderlow-growingshrubs

p. 14...................................... Bauderfollow-upcare

p. 15...................................... Bauderdevelopmentandmaintenancecare

p. 15...................................... Installationthicknesses

Page 3: terase verzi

Extensive planting – more than a protective eco-layer

In line with the general trend towards eco-building, the extensive planting system has now been established for some time. However, it is much more than a simple protective eco-layer or a necessary balancing measure.

Extensiveplantingsystemsstorewater,binddust,barelyheatupatall,evenatextremetemperatures,andthereforebringaboutasustainableimprovementinthemicro-climateontheroof.Theycreateapositiveimage,improvethequalityoflifeandalsocontributetotheincreasedappreciationofthebuildingvalue.

Floraandfaunahappilypopulatenewhabitatsandtheroofitselfenjoysalongerlife,becauseitiseffectivelyprotectedagainstenvironmentalinflu-ences.Thereisalsotheaddedbonusofareductioninthe‘raintax’inareaswheretheyhavesplitthewastewaterdrainagecharge.

Moreandmoredevelopersarebeco-mingconvincedofthesebenefitsandareinvestingingreenrooflandscapes.Thecostsforthisinvestmentaretrans-parent,becausethin-layerconstruc-tionswithacorrespondinglowweightperunitareaandnatural-lookingvege-tationthatmanageswithoutartificialirrigationmakeextensiveplantingacost-effective,low-maintenanceformofroofplanting.

Page 4: terase verzi

Extensive planting to suit individual requirements

The multi-layer construction, made up of a filter, drainage and vegetation layer, offers the best conditions for maintaining long-lasting, high quality extensive planting schemes.

Thedemandsmadeontheextensi-veplantingsystemconstructionvaryaccordingtotheroofsituationandtheplantingobjective.Theentireband-width,fromparticularlyeconomicalconstructionstoverysophisticatedplantingsystems,canbeachievedwiththeBaudersystemoptions.Specialsolutions,likeplantingroofswithoutanyfall,forexample,ordrainagepassingunderneathplantingandcoveringareasrequiringgreatercapacitytowithstandpressure,canbecreatedeasilyandreliablywithBauder.

Thecriteriaforchoosingtherightsystemaredescribedonthefollowingpage.Thebriefdescriptionsprovideadecision-makingaidforselectingthebestsystemsolutionbasedonthedemandsmadeonthedrainagelayer.TheBauderplantcompostR-Ehaspro-vedparticularlysuccessfulinaccom-modatingthevegetationlayer.However,alltheotherBauderextensivevegeta-tionsubstratescan,ofcourse,alsobeusedformulti-layerconstructions.

Page 5: terase verzi

Bauder SDF mat – the budget drainage system

Ifnoparticulardemandsaremadeonthedrainagelayer,theSDFmatcanbeusedfortheconstruc-tion.TheSDFmatallowstheprotective,drainageandfilterlayertobeinstalledinasingleoperationandisthereforecorrespondinglycheaper.TheconstructionwiththeSDFmatisourstandardconstructionforextensiveplantingusingamulti-layersystem.Becauseofitspermeabledrainage,itcanalsobeusedwithareversedroof(seepage7).

Criteria for selecting the system

Ifdrainagepassesunderplantingorterraceslabs,theBauderdrainageandstorageelementN20needstobeinstalledinsteadoftheSDFmat.Thiselementisessentiallyabletowithstandgreaterpressureandisalsosuitableasdrainageundermarginalpavingslabssetinamortarbed(seepage8).

Bauder drainage and sto-rage element N 20 – the drainage system that will withstand pressure

Bauder water storage panel – the sophisticated planting system

Bauder mineral drain – coarse mineral particles

Insteadofplasticsheetelements,coarsemineralparticlescanalsotakeoverthedrainagefunction(seepage12).

ThehighstoragecapacityoftheBauderwaterstoragepaneloffersthebestgrowingconditionsforthevegetation.Thethicknessofthepanel–�0mm–alsoallowstheplantingofroofswithoutanyfall.Anywaterthataccumulatesisdisplacedbythepanel(seepage10).

Page 6: terase verzi

Bauder SDF mat - budget drainage system

1 Planting

Hydrosowing-BaudersprayplantingorplantingwithBauderlow-growingshrubs.

2 Vegetation layer

Bauderextensiveplantcompost,amixtureofcoarsemineralparticleswithsmallquantitiesofanorganicsub-stanceforextensiveplantinginmulti-layerconstructionsinaccordancewithFLLguidelines,completewithtestcerti-ficate.Installationthickness8cm.

3 Protective, drainage and filter layer

BauderSDFmat,protective,drainageandfiltermatinextrudedpolypropylenemonofilaments,withaprotectivenon-wovenfabriclayerunderneath,afilternon-wovenfabriclayerontopandthelayersoverlappedattheside,thickness20mm.

4 Separating and sliding layer

BauderseparatingfilmPE02,bitumenandpolystyrene-resistantpolyethyle-nefilmmadefromrecycledgranulate.Thickness0.2mm.

1

3

4

2

Technical data

Roofangle1º-�ºIftheangleis0º,specificadviceforthebuildingisneeded

Constructionheight 10,0cm

Waterstoragecapacity �8l/m

Weights per unit area(allfigureswithmax.watercapacity)

Separatingfilm* 0,2kg/m2

SDFmat 1,0kg/m2

PlantcompostR-E,installationthickness8cm 100,0kg/m2

VegetationinaccordancewithFLL 10,0kg/m2

Total weight 111,2kg/m2

*separatingfilmnotneededfroma�°roofangle

Page 7: terase verzi

7

Bauder drainage and storage element N 20 – drainage that will withstand pressure

1 Planting

Hydrosowing–BaudersprayplantingorplantingwithBauderlow-growingshrubs.

2 Vegetation layer

BauderExtensiveplantcompost,amixtureofcoarsemineralparticleswithsmallquantitiesofanorganicsubstanceforextensiveplantinginmulti-layerconstructionsinaccordancewithFLLguidelines,completewithtestcertificate.Installationthickness8cm.

3 Filter layer

Baudernon-wovenfilterfabric,staplefibrenon-wovenfabricfromneedle-punchedpolypropylene.Weightperunitarea10�g/m2.

4 Water storage and drainage layer

BauderdrainageandstorageelementN20,HDPEdrainageelementthatwillwithstandpressure,tuftheight20mm,waterstoragecapacity�l/m2,pressureresistance1�0kN/m2.

5 Protective layer

Bauderprotectivenon-wovenfabricW�00,mechanicallyandthermallybon-dedrecycledfabricfromPESandPPregenerate,weightperunitarea�00g/m2,waterstoragecapacity2.�l/m2.

6 Separating and sliding layer

BauderseparatingfilmPE02,bitumenandpolystyrene-resistantpolyethyle-nefilmmadefromrecycledgranulate,thickness0.2mm.

2

1

4

5

3

6

Technical data

Roofangle1º-�ºIftheangleis0º,specificadviceforthebuildingisneeded

Constructionheight 10,0cm

Waterstoragecapacity ��l/m

Weights per unit area(allfigureswithmax.watercapacity)

Separatingfilm* 0,2kg/m2

Protectivenon-wovenfabricW�00 2,�kg/m2

DrainageandstorageelementN20 7,0kg/m2

Filterlayer 0,2kg/m2

PlantcompostR-E,installationthickness8cm 100,0kg/m2

VegetationinaccordancewithFLL 10,0kg/m2

Total weight 120,0kg/m2

*separatingfilmnotneededfroma�°roofangle

Page 8: terase verzi

8

1 Planting

Hydrosowing–BaudersprayplantingorplantingwithBauderlow-growingshrubs.

2 Vegetation layer

BauderplantcompostR-E,amixtureofcoarsemineralparticleswithsmallquan-titiesofanorganicsubstanceforexten-siveplantinginmulti-layerconstructionsinaccordancewithFLLguidelines.Installationthickness8cm.

3 Filter layer

Baudernon-wovenfilterfabric,staplefibrenon-wovenfabricfromneedle-punchedpolypropylene.Weightperunitarea10�g/m2.

4 Water storage and drainage layer

Bauder�0mmwaterstoragepanelinrigidpolystyrenefoamwithrecycledconstituentsandprofiledunderside.Waterstoragecapacity10l/m2,elementheight�0mm.

5 Protective layer

Bauderprotectivenon-wovenfabricW�00,mechanicallyandthermallybon-dedrecycledfabricfromPESandPPregenerate,weightperunitarea�00g/m2,waterstoragecapacity2.�l/m2.

6 Separating and sliding layer

BauderseparatingfilmPE02,bitumenandpolystyrene-resistantpolyethyle-nefilmmadefromrecycledgranulate,thickness0.2mm.

3

5

6

4

2

1

Bauder water storage panel – the sophisticated planting method

Technical data

Roofangle0º-�º

Constructionheight 1�,0cm

Waterstoragecapacity �0l/m

Weights per unit area(allfigureswithmax.watercapacity)

Separatingfilm* 0,2kg/m2

Protectivenon-wovenfabricW�00 2,�kg/m2

�0mmwaterstoragepanel 11,0kg/m2

Filterlayer 0,2kg/m2

PlantcompostR-E,installationthickness8cm 100,0kg/m2

VegetationinaccordancewithFLL 10,0kg/m2

Total weight 12�,0kg/m2

*separatingfilmnotneededfroma�°roofangle

Page 9: terase verzi

1 Planting

Hydrosowing–BaudersprayplantingorplantingwithBauderlow-growingshrubs.

2 Vegetation layer

BauderExtensiveplantcompost,amixtureofcoarsemineralparticleswithsmallquantitiesofanorganicsubstanceforextensiveplantinginmulti-layerconstructionsinaccordancewithFLLguidelines,completewithtestcertificate.Installationthickness�cm.

3 Filter layer

Baudernon-wovenfilterfabric,staplefibrenon-wovenfabricfromneedle-punchedpolypropylene.Weightperunitarea10�g/m2.

4 Water storage and drainage layer

Baudermineraldrain,coarsemineraldrainageparticlesinaccordancewithFLL,installationthickness�cm.

5 Protective layer

Bauderprotectivenon-wovenfabricW�00,mechanicallyandthermallybon-dedrecycledfabricfromPESandPPregenerate,weightperunitarea�00g/m2,waterstoragecapacity2.�l/m2.

6 Separating and sliding layer

BauderseparatingfilmPE02,bitumenandpolystyrene-resistantpolyethyle-nefilmmadefromrecycledgranulate,thickness0.2mm.

3

5

6

4

2

1

Bauder mineral drain – coarse mineral particles

Technical data

Roofangle0º-�º

Constructionheight 1�,0cm

Waterstoragecapacity �0l/m

Weights per unit area(allfigureswithmax.watercapacity)

Separatingfilm* 0,2kg/m2

Protectivenon-wovenfabricW�00 2,�kg/m2

MineraldrainL2/11,installationthickness�cm �2.�kg/m2

Filterlayer 0,2kg/m2

PlantcompostR-E,installationthickness�cm �0,0kg/m2

VegetationinaccordancewithFLL 10,0kg/m2

Total weight 12�,�kg/m2

*separatingfilmnotneededfroma�°roofangle

Page 10: terase verzi

10

With the Bauder light green roof system, roof constructions with redu-ced load bearing capacity can also be planted.

Lightroofconstructionsarenotonlyprevalentinindustrialandcommercialbuildingsthesedays.Theseroofcon-structionsonlyhavesmallloadmarginsasarule.Withawater-saturatedweightofmorethan100kg/m2,itisoftennolongerpossibletousethestandardsystemconstructions.ThesystemconstructionwiththeBauderwaterstoragepanelhasbeenspeciallydevelopedforthisapplication.Thehighstoragecapacityofthewaterstoragepanelallowsaninstallationthicknessofthevegetationlayerthatisreducedto�cm.Togetherwithalow-weightvegetationsubstrate–BauderplantcompostPO-E–theweightperunitareaofthetotalcon-structionisjust��kg/m2inthewater-saturatedstate.

Extensive planting for roof constructions with reduced load bearing capacity

Page 11: terase verzi

11

1 Planting

Hydrosowing–BaudersprayplantingorplantingwithBauderlow-growingshrubs.Becauseofaninstallationthick-nessofthevegetationsubstrateofjust�cm,thediameteroftheshrubmustnotexceed�cm.

2 Vegetation layer

BauderplantcompostPO-E,amixtureofcoarsemineralparticleswithsmallquantitiesofanorganicsubstanceforextensiveplantinginmulti-layercon-structionsinaccordancewithFLLguide-lines.Installationthickness�cm.

3 Filter layer

Baudernon-wovenfilterfabric,staplefibrenon-wovenfabricfromneedle-punchedpolypropylene.Weightperunitarea10�g/m2.

4 Water storage and drainage layer

Bauder�0mmwaterstoragepanelinrigidpolystyrenefoamwithrecycledconstituentsandprofileontheunder-side.Waterstoragecapacity10l/m2,elementheight�0mm.

Bauder water storage panel with light substrate – planting system for trapezoidal sheet roofs

3

4

2

1

Technical data

Roofangle0º-�º

Constructionheight 10,0cm

Waterstoragecapacity 2�l/m

Weights per unit area(allfigureswithmax.watercapacity)

�0mmwaterstoragepanel 11,0kg/m2

Filterlayer 0,2kg/m2

PlantcompostPO-E,installationthickness�cm ��,0kg/m2

Total weight ��,2kg/m2

*Totalweightincl.vegetationapprox.70kg/m2

Page 12: terase verzi

12

With extensive planting over a wide area, a multi-layer construction is, as a rule, too complicated.

Themono-layerconstructionhaspro-vedsuccessfulhereasareasonablecompromiseintermsofcostandresult.Themono-layerconstructionallowslargeareastobeplantedinashorttimeandatlowcost.Withthisextremelysimpletypeofconstruction,ahomoge-nouslayeroftheBaudermineralplantsubstratetakesoverthefunctionsofdrainage,filterandvegetationlayer.Themono-layerconstructionmakesparticularlyhighdemandsonthequalityofthevegetationsubstratesused.Allthreefunctions–drainage,filteringandplantgrowth–takeplaceinasinglelayer.Hardlyanyothermanufacturerhaspaidasmuchattentiontotheseparticularfeaturesofthemono-layerconstructionasBauder.TheBaudermono-layersubstratesincorporatetheexperienceofmanyyearsofsuccessfulmono-layerplanting.

Extensive planting for large roof areas

Page 13: terase verzi

1�

Roof angle 1º- 3º

1 Planting

Hydrosowing–BaudersprayplantingorplantingwithBauderlow-growingshrubs.

2 Vegetation, filter and drainage layer

Bauderplantsubstrate,amixtureofcoarsemineralparticlesforextensiveplantinginmono-layerconstructionsinaccordancewithFLLguidelines,com-pletewithtestcertificate.Installationthickness10cm.

3 Protective layer

Bauderprotectivenon-wovenfabricW�00,mechanicallyandthermallybon-dedrecycledfabricfromPESandPPregenerate,weightperunitarea�00g/m2,waterstoragecapacity2.�l/m2.

4 Separating and sliding layer

BauderseparatingfilmPE02,bitumenandpolystyrene-resistantpolyethyle-nefilmmadefromrecycledgranulate,thickness0.2mm.

Roof angle 3º- 10º

Theseparatingandslidinglayerisnotrequiredfromaroofangleof�°.Inordertocountertheincreasedsur-facerun-off,plantcompostwithagreaterstoragecapacityisusedinsteadofplantsubstrate.Theprotectivenon-wovenfabricW�00actsasanadditio-nalwaterstorageelement.

3

4

2

1

Bauder plant substrate – the budget solution

Technical data

Roofangle1º-10º

Constructionheight 10,0cm

Waterstoragecapacity 2�l/m

Weights per unit area(allfigureswithmax.watercapacity)

Separatingfilm* 0,2kg/m2

Protectivenon-wovenfabricW�00 2,�kg/m2

PlantcompostR,installationthickness10cm 110,0kg/m2

VegetationinaccordancewithFLL 10,0kg/m2

Total weight 122,8kg/m2

*separatingfilmnotneededfroma�°roofangle

Page 14: terase verzi

1�

Extensive system planting

HÄMMERLE PLANTING SYSTEMS- Systems for extensive and intensive roof planting- Bauder spray planting

Net green area ≥ 150 m2

TheBaudersprayplantingmethodusesspecialmachinestomakealiquidmix-tureofvariousadditives,sedumshootsand/orseeds,whichisthensprayedontothevegetationsubstratemechanical-lyinasingleoperation.ThismakestheBaudersprayplantingmethodthemostefficientwayfortheextensiveplantingoflargeroofareas.Twotypesofsprayplantingsystemsareavailable–thehydrosowingofpuresedumshootsorcombinedwithwildflowersandwildherbseeds.

Standardassortmentsareavailablefordifferentlocations(sun,shade,semi-shade).Shrubswitha�–�cmdiametershouldbeplantedattherateof12/m2.

Planting with Bauder low-growing shrubs

Net green < 150 m2

Sprayplantingisnoteconomicalforplantingareasoflessthan1�0m2.Thebestmethodforplantingsmallareasistoplantlow-growingshrubs.Theshrubsaremainlynurturedandstress-conditio-nedinamineralsubstrate.

Bauder follow-up care – only in conjunction with hydro sowing

Extensiveplantingislowmaintenance–butnotmaintenance-free.Togua-ranteesuccessfulplanting,follow-upcareisessential.

Follow-upcaremeasuresinclude:

nre-sowingbarepatcheswithseedorsedumshoots

ncontrollednutrientfeedasrequirednremovalofweeds.

Inadditiontothisvegetationcare,thefollow-upcarealsoincludescheckingandcleaningtheroofdrains.

Thefollow-upcareendswhenaccep-tancestatusisreached–usuallyafter12–18months.

Withoutafollow-upcareorder,weonlyguaranteeourprofessionalsprayplan-tingworkandtheuseofproblem-freeadditives.

Themainacceptancecriteriaare:

ntheremustbeauniformplantstockwithaprojectivecoverofatleast�0%.Thecoverdoesnotincludeasexualandextraneousvegetation,whichmustnotexceed20%.

nBeforeacceptance,thevegetationshouldhavesurvivedarestperiodandalsoadroughtorfrostperiodifpossible.

Page 15: terase verzi

1�

Bauder development and maintenance care

Attheendofthefollow-upcareperiod,acareandmaintenanceagreementshouldbesigned,atleastforthedura-tionoftheguarantee.Aspartofthedevelopmentandmaintenancecare,theroofareaswillbecheckedduringonetotwoinspectionvisitsayearand,ifnecessary,thefollow-upcaremeasu-reswillbecontinued,but,asarule,lessintensely.

Thepermanentfunctionoftheroofplantingcanonlybeguaranteedbyacontinuingdevelopmentandmainte-nancecarecontract.

Installation thicknesses

Theinstallationthicknessesspecifiedfortheindividualconstructionsarebasedontherequirementsrelatingtosedum/grass/herbvegetation.

Ifonlysedumisplanted,theinstallati-onthicknessesofthevegetationlayercanbereducedbyapprox.2cm,sothatinthecaseoftheconstructionwiththeBauderSDFmat,a�cm(ratherthan8cm)layerofplantcom-postR-Eissufficient.

Inthecaseofamono-layerconstruc-tionwithsedumplanting,theinstalla-tionthicknesscanbereducedcorre-spondinglyto8cm.Anyfurtherreduc-tionintheinstallationthicknessplacesthepermanentfunctionguaranteeoftheroofplantingatrisk.

Page 16: terase verzi

Pleasealsoseeourinformationbrochu-resonintensiveandsteeproofplanting.

GreenroofsarejustoneofthemanyfacetsofBauder’scompetence.Wealsoofferthehighestqualityandexpertknowledgeinflatroofandpit-chedroofseals–includingheatinsu-lationandalltheotherprotectivefunc-tionsrequired.

Werk StuttgartPaulBauderGmbH&Co.KGKorntalerLandstraße��D-70���StuttgartTelefon0711/8807-0Telefax0711/8807-�[email protected]

0�10/0�07GBDW

Alltheinformationinthisleafletisbasedonthepresentstateoftheart.Wereservetherighttomakechanges.Ifnecessary,pleaseenquireaboutthelatesttechnicalknow-howavailableatthetimeofyourorder.