TemperatureandHumidityTestChamber TechnicalData€¦ · Distributed by: Reliant EMC LLC, 3311 Lewis...

12
Temperature Temperature and and Humidity Humidity T T est est Chamber Chamber Technical Technical Data Data Reliant EMC LLC 3311 Lewis Ave Signal Hill, CA 90755 Tel.:(408)916-5750 E-Mail: contact@reliantemc.com Web: www.reliantemc.com

Transcript of TemperatureandHumidityTestChamber TechnicalData€¦ · Distributed by: Reliant EMC LLC, 3311 Lewis...

Page 1: TemperatureandHumidityTestChamber TechnicalData€¦ · Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 4089165750, . Mainsparepartslist: NO Material name

TemperatureTemperature andand HumidityHumidity TTestest ChamberChamber

TechnicalTechnical DataData

Reliant EMC LLC 3311 Lewis Ave Signa l Hill, CA 9 0755 Tel.:(408)916-5 750

E -M ail: contact@reliantem c.com Web:w ww.reliantemc.com

Page 2: TemperatureandHumidityTestChamber TechnicalData€¦ · Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 4089165750, . Mainsparepartslist: NO Material name

The reason for choosing SANWOOD Equipment

Technical Features

A.USB disk recording function, do not need recorder;

B.The wide range of temperature and humidity,the standard model can reach 60 (40) 10%RH;

1. Refrigerant servo valve control flow calculation, energy saving more than 30%;

2. High temperature and high humidity test to prevent condensation of moisture and drip,the technology

ranks first in this industry

3. Low temperature working state, the heater does not participate in the work, through the PWM technology

to control the refrigerant flow and flow direction, the cooling pipe, cold bypass pipe, heat bypass pipe three to

flow regulation, to achieve automatic constant temperature of the studio. This method can reduce the energy

consumption by 40%;

4. Temperature and humidity control of synchronous lifting slope, no drop, no condensation;

5. Low noise, only 55dB at low temperature testing;

6. Refrigeration advantages:

7. Low temperature control method of traditional equipment:

Ø Constant operation of refrigeration compressor + Heating PID control Refrigeration and heating

temperature offset achieve dynamic balance, wasting a lot of energy.

Realization of low temperature energy saving operation with new PWM cold control technology

Low temperature working state, the heater does not participate in the work, through the PWM technology

to control the refrigerant flow and flow direction, the cooling pipe, cold bypass pipe, heat bypass pipe

three to flow regulation, to achieve automatic constant temperature of the studio. This method can reduce

the energy consumption by 40%.

The technology based on the United States Sporlan company customized model PWM control valve:

Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 408­916­5750, www.reliantemc.com

Page 3: TemperatureandHumidityTestChamber TechnicalData€¦ · Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 4089165750, . Mainsparepartslist: NO Material name

Core Spare Parts:

German Schneider Contactor German Schneider Thermal Relay Izumi Japanese Rely high and low voltage protection switch

Yangming solid state relay songqi Temperature sensor Dongyuan Circulating Motor Sporlan refrigeration solenoid valve

Taiwan Jianli stainless steel wind wheel Taiwan FeiYang Heating Tube Taiwan Zhongli evaporator

Mobile castors Rack oil separator

France Tecumseh Compressor South Korean Controller

Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 408­916­5750, www.reliantemc.com

Page 4: TemperatureandHumidityTestChamber TechnicalData€¦ · Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 4089165750, . Mainsparepartslist: NO Material name

Main spare parts list:NO Material name Origin / brand Model Quantity life-span1 Temperature and humidity

controllerSouth KoreaSAMWON

TEMI-1500 1 15 years

2 AC contactor German Schneider LC1-D25 4 15 years3 Thermal Relay German Schneider LRD-08KN 2 10 years4 Intermediate Relay Izumi Japanese RU4S-A220 5 10 years5 Time Relay Taiwan AnLiang AH3-3 1 8 years6 Over Temperature

ProtectionSouth KoreaRAINBOW

TS-320S 210 years

7 Solid State Relay Taiwan Yangming SSR-40DA 6 8 years8 Temperature and Humidity

SensorTaiwan Songqi PT100 2

15 years

9 Lamp LED 12V\18W 2 15years10 Leakage switch South Korea LG DP-40A 1 15years11 Signal Indicator Taiwan Tiande AD16-22D/S31 1 10 years12 Flash buzzer Taiwan Tiande AD16-22SM 1 10 years13 Switching Power Supply Taiwan Mingwei NES-100-24 2 10 years14 No fuse switch German Schneider LC-1P20A 2 10 years15 Button Switch Taiwan Tiande AD-22D/S31 2 15 years16 Circulating Motor Taiwan Dongyuan DL-220V90W 1 10 years17 Circulating Wind Wheel Taiwan Jianli 7CL 1 10 years

18 Heating Tube Taiwan Feiyang Customized 2 10 years19

Pump MotorNew Western Hills

joint ventureDP-125 1

15 years

20 Liquid TemperatureController

RAINBOW SouthKorea RAINBOW

RA-10KG 115 years

212P compressor

France TecumsehCompressor

TFH-2480Z-T 215 years

22 Condenser Taiwan Zhongli ZL-2P 2 10 years23 Evaporator Taiwan Zhongli ZL-2P 2 15 years24 Condenser fan Germany EBM 4E-350-Z 1 10 years25 Drying filter Danfoss 083S 2 15 years26 Expansion valve Danfoss TS-2S 2 15 years27 Solenoid valve Danfoss DA-083 3 15 years28 Refrigerant AmericanLianxing R404A/R23 2 15 years29 Refrigeration oil BritishBingxiong RL32H 2 15 years30 Oil separator America ALCO S-4004 1 15 years31 Vacuum Heating Glass Taiwan DSD Customized 1 15 years32 Cooling Fan Taiwan Jianzhun EB-120 1 10 years33 Lock America Shangkun SK1-200 1 15 years34 Casters Taiwan Zhide Customized 4 15 years35 Horizontal Wheel Taiwan Zhide Customized 4 15 years

Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 408­916­5750, www.reliantemc.com

Page 5: TemperatureandHumidityTestChamber TechnicalData€¦ · Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 4089165750, . Mainsparepartslist: NO Material name

Main technical parameters:1. Equipment performanceProduct performance Air cooling, no-load, machine air cooling type at room temperature 25, or

water temperature at 25Name temperature and humidity test chamber

Model SMC-225-CCInner dimension 50 x75 x60cm ( W x H x D )Inner volume 225LOuter dimension 80 x 160 x145 cm ( W x H x D )Temperature Range -70℃~180℃Humidity Range 10%~98%Heating Rate 3.0℃~5.0℃/minCooling rate 0.7℃~1.5℃/minTemperature and degree distributionuniformity

±1℃

Temperature controlled wave motion ±0.1℃Temperature deviation ±1℃Temperature stability time ≤10min;Humidity distribution uniformity ±2%Humidity control fluctuation ±2%Humidity deviation ±2%Humidity stability time ≤10minWeight 360KG

2. Mechanical structure design2-1. Inner box material Heat resistant stainless steel plate welding(SUS #304)2-2. Outer box material The outer box adopts galvanized high baking powder or cold hot resistant stainless

steel plate2-2. Main structure design The sheet metal area, circuit area, frozen zone, water zone, the four parts.2-3. Heat/Cold storage material High efficiency aluminum alloy thermal storage production capacity and cold heat

exchange capacity of super efficiency.

2-4. Observation windowInstallation of rectangular multi - layer insulating glass observation window (570 x420mm) to install energy-saving LED lighting source

2-5. Sample rack bearing A layer of no more than 30 kg

2-6. Sample rack moving mode The sample rack is mounted on the bottom of the box body and moves up and down.2-7.Insulat ion layer Heat insulation layer flame retardant PU+Heat insulation glass wool(10.0cm Insulation

layer)2-8. Box frame Adjustable grid frame and 2 stainless steel strip grid (Disk frame 5.0cm distance)2-9.Machine positioning The machine bottom is equipped with 4 high load bearing blocks and the PU horizontal

angle wheel is in favor of moving the machine.2-10.Box body structure Taiwan original plane embedded rotating handle

Hinge: the original Japanese imports, can prevent the box door any shaking, the material is#304 SUS;

Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 408­916­5750, www.reliantemc.com

Page 6: TemperatureandHumidityTestChamber TechnicalData€¦ · Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 4089165750, . Mainsparepartslist: NO Material name

The use of energy-saving 18W LED, can be clearly seen in the box four corner test items;3. Temperature and humidity electric heating cycle system3-1Electric heating cycle system Temperature mining special moisture and heat dissipation design,

stainless steel extended axis motor3-2 Circulating wind High / low temperature aluminum alloy multivane circulating fan3-3. Electric control mode of heat storagezone

Balanced temperature control of S.S.R P.I.D

3-4. Structure microcomputer controlMicrocomputer control, pre cooling preheating temperature conversioncontrol, output power from the computer to achieve high accuracy and highefficiency.

3-5. Auto-Control

The U type fin type high-speed heating electric heaterFully independent system does not affect the frozen and control lineCalculation of the heat content of the test object with the heating rate

3-6. Humidification system

Electronic and position method for micro wetting systemThe wet barrel is made of stainless steel, and with a water level observationwindowDouble guarantee device for overheat and overflowWet and desiccant system is completely independent.The water level control adopts the mechanical float ball water raft,anti-electronic type of mistakeFor wet water use automatic replenishment system with filter, the buyer doesnot need to manually add water.The use of non recycling water system

3-7.Desiccant systemIndependent refrigeration compression systemDew point temperature (ADP) laminar flow contact and desiccant method forevaporating vessel

4.Refrigeration system:Using binary-type refrigeration systems, good efficiency, energy-saving4-1. Refrigerating apparatus Europe and high efficiency ultra-low temperature refrigeration compressor

(air cooling mode)4-2. Heat exchanging devices The design of the SWEP plate cold coal exchange with high efficiency

which is more traditional..

4-3. Heating load regulation

Automatic adjustment of cold coal flow by computer,Effectively take theheat load of the sample and the German / Japanese technologysimultaneously,Compared with the traditional design, the stability andreproducibility of the control is high and the efficiency of power saving isachieved.

4-4. Condenser Using water cooling or air cooling heat dissipation method for the largesystem of the water - collecting pipe type and the tube type

4-5.Super efficiency refrigeration controlrefrigerant The refrigerant pipes are welded with the nitrogen pressure and leak test.

4-6. Evaporator High efficiency components using slope type evaporator,(AC&R doubleturbulent type aluminium fins)

Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 408­916­5750, www.reliantemc.com

Page 7: TemperatureandHumidityTestChamber TechnicalData€¦ · Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 4089165750, . Mainsparepartslist: NO Material name

4-7. Standard modular design Compatibility and interoperability of components of high quality stability4-8. Extended Performance The TEMI1500 control system can be reserved for isothermal control of

liquid nitrogen valve LN2V & FV control interface.4-9. Extensions Work long hours with low evaporator icing automatic defrost circuit

4-10.Special functionsMulti-wing circulating fan, forced convection air flow to improve theefficiency of uniform temperature

4-11.Special functionsThe test area is controlled by P.I.D.+S.S.R. microcomputer, which canachieve the control precision.

4-12.Refrigerant United States DuPont green refrigerant R404a and R23a

4-13.Auxiliary Original

Expansion valve(America SPOLAN),Solenoid valve(ItalyCASTEL),Filter(America SPORLAN),Pressure controller(Anglo AmericanRANCO),Oil separator(Europe ALCO) etc refrigeration accessories areimported parts

5. Control system((TEMI-1500 )5-1.Controller combinationA. Controller type TEMI-1500B. Controller origin South Korea SAMWONC.Temperature sensor JIS RTD PT 100 Ω × 2 Platinum sensor

D. Controller function

5.7 inch LCD touch control screen, 12000 groups of 120 programming, 9999 cyclessetAnd with a number of PID control, the display screen 240 x 320 point wide viewingangle, high contrast with the large LCD display screen

E. Controller specification

a. Temperature resolution:0.1℃b. Operation mode: Program running, Set operationc. Equipment working time cumulative timerd. PID control mode

F T e m p e r a t u r ec o n v e r t e r

A microcomputer multifunctional automatic linear compensation and correction,temperature converter

G. Screen display

a. The control software on screen, the screen directly touch options, including bootsettings,Loop, program, display screen, auxiliary setting, system opening programcapacity and control functionb. With temperature setting, humidity setting indicatorc. Can display the current state of execution, temperature setting, time setting, therest time, the remaining number of cyclesd. Function of fault condition and fault elimination method in English,machine cannot started with fault unsolved

H. Program capacity and controlfunction

a. Can be used by the amount of the program: the maximum 999 groupsb. Can be repeated orders: each command can be 9999 timesc. Time setting 0~9999Hr59mind. Have an appointment start functione. Key and screen lock (LOCK) functionf. Temperature defrosting time settingg. Attached RS232 communication interface and USB interface.

Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 408­916­5750, www.reliantemc.com

Page 8: TemperatureandHumidityTestChamber TechnicalData€¦ · Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 4089165750, . Mainsparepartslist: NO Material name

h. The temperature, time and the number of cycles can be set.5-2. Controller main functionA.Temperature analytic ability 0.01 ℃

B. Temperature control accuracy ± 0.2 ℃

C. Set time capacity 0 H 1 M ~ 9999 H 59 MD. Display language Chinese (Traditional) / EnglishE. Reservation start-up time Reservation time setting function.F. Calculation control Automatic temperature program change control and program link control.G. Screen display Color real time curve display screen (set).

Test curves show, no time limit, sampling rate automatically adjustH. Software device for fault record Control of storage / record / analysis when the machine is maintained.I.Controller deviation setting Intelligent digital temperature deviation "return to zero"J. Call back after selection Call back after the blackout "continue" "to" "stop" setting.

K. Control software

Automatic adjustment of the cold coal flow, effectively take the heatload of the sample to be measured with the German / Japanesetechnology Compared with the traditional design, the stability andreproducbility of the control is high and the efficiency of power saving isachieved.

L. Upper and lower limit oftemperature protection

Set up the test procedure, and automatically set the upper and lower limits ofthe low temperature protection.

M. Power failure memory device Ensure that the stored procedures in the power failure to maintain memorydata

I. Security permission settings Machine operation password permission settingsO. Mode Selection Programmable control mode6. Safety protection system6-1. Leakage / burst protection Leakage protection of electric wave of leakage protection.6-2. Prevention of lightning protection Controller AC power supply is equipped with the arrester ZRN device

6-3. Overload protection deviceAC Power Supply ,Three phase power supply. Reverse phase protectionand current load over load (over load)High temperature and high temperature protection operation control of hightemperature and low temperature protection setting

6-4. Compressor protection Cold media pressure protection and overload protection device.Cold media pressure protection and overload protection device.Compressor internal overheat protectionCompressor high and low voltage protectionCompressor startup exception protectionCompressor oil pressure difference protection

6-5. Protector 1 group humidification barrel dry protection switch1 groups of low water level protection1 group of heating system protection switchHeater short circuit protectionTemperature and humidity over temperature balance device

6-6. Fault exception protection Fault exception occurs when the control power supply cut off and cause of themalfunction indication and alarm output signal

Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 408­916­5750, www.reliantemc.com

Page 9: TemperatureandHumidityTestChamber TechnicalData€¦ · Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 4089165750, . Mainsparepartslist: NO Material name

7.Standard configuration:7-1.Test hole ψ100mm a hole on the left side of the body attached to a stainless steel manhole

covers, silicone plugs 17-2 Over-temperature protection LED digital microscopic computer controller, preventing the sample temperature

too high or too low7-3. Fuse Backup fuse7-4. Instruction manual Controller instruction manual, Operating instruction manual

Product qualification certificate

7-5.Other standard configuration

4 Sample frame2 groups of adjustable spacing 50mm rack rail4 Adjustable horizontal cup wheels6 meters 5X6 square low impedance rubber cable

8. Use requirements

8-1.Environmental requirements

Allowable temperature range 0~25℃Performance guarantee range 5~25℃Relative humidity:≤85%RH

Air pressure:86kPa~106kPaCooling circulating water: NullCompressed air: Null

8-2. Site requirements

Smooth ground, well ventilated, non flammable, explosive, corrosive gas anddustNear no strong electromagnetic radiation sourceA floor drain near the equipmentGround bearing capacity: not less than 800KG/ square metersReserved space for proper maintenance.

8-3.Requirements forstorage environment

When the equipment works, the temperature of the environment should be keptwithin 0 ~ +4 (not frozen).When the equipment works, the temperature of theenvironment should be kept within 0 ~ +4 (not frozen).When the equipment works, the temperature of the environment should be keptwithin 0 ~ +4 (not frozen).The temperature is below 0 ~ +4 in the north of the room can not be frozenphenomenon, to ensure that the interior is not frozen, to ensure the normal use ofequipment.

9、Power supply system: the system power fluctuation is not greater than 10%

ModelVoltage220V±10Rated current

SMC-225-CC series 45APower 5.5KW

Quality Assurance

In order to further improve the company's product and company managementlevel, to provide users with high brand, high quality, high efficiency, world-classhigh-service environmental testing equipment, the company strictly inaccordance with IS09001: 2008 version of the standard of quality assurancesystem operation. Products manufactured before the quality department need to

Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 408­916­5750, www.reliantemc.com

Page 10: TemperatureandHumidityTestChamber TechnicalData€¦ · Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 4089165750, . Mainsparepartslist: NO Material name

undergo a quality inspection of about a week, to ensure product quality andinterests of users

Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 408­916­5750, www.reliantemc.com

Page 11: TemperatureandHumidityTestChamber TechnicalData€¦ · Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 4089165750, . Mainsparepartslist: NO Material name

Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 408­916­5750, www.reliantemc.com

Page 12: TemperatureandHumidityTestChamber TechnicalData€¦ · Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 4089165750, . Mainsparepartslist: NO Material name

Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 408­916­5750, www.reliantemc.com