Telephone & Exchange Tester ETET 30

download Telephone & Exchange Tester ETET 30

If you can't read please download the document

description

Telephone & Exchange Tester ETET 30. ELEKTR NIKA. ETET 30 is a central office installed touch screen controlled instrument intended to identify the cause of subscriber complaints. The operator can test: ● The circuits of exchange ● The operation of DSLAM ● The parameters of line - PowerPoint PPT Presentation

Transcript of Telephone & Exchange Tester ETET 30

  • Telephone & Exchange Tester ETET 30 The operator can test: The circuits of exchange The operation of DSLAM The parameters of line The subscribers phone set The noise spectrum

    Test groups: User Side Tests Exchange Side Tests Modem Detection ADSL Test VDSL TestETET 30 is a central office installed touch screen controlled instrument intended to identify the cause of subscriber complaints.ELEKTR NIKAFor details click on the corresponding keys.

  • User Side Tests of ETET 30ELEKTR NIKAFor details click on the corresponding keys.The user side tests are intended: To test the access line when the subscribers phone is in on-hook state. To test the subscribers phone set with his assistance.

    Selectable Modes: DMM TDR Spectrum analyser Test Call

  • User Side DMM MeasurementsELEKTR NIKAVoltage Measurements AC, DC voltages between wire A and GND AC, DC voltages between wire B and GND AC, DC voltages between wires A and BInsulation Resistance Measurements Between wire A and GND (RAE) Between wire B and GND (RBE) Between wires A and B (RISO) with normal and reversal polarityCapacitance Measurements Between wire A and GND (CAE ) Between wire B and GND (CBE ) 2 Pole capacitance between the wires Load capacitance CLAutomatic Test Sequence Pressing the Auto key ETET 30 performs the previous measurements.Continuity Measurement In this mode ETET 30 performs loop resistance measurement. If the loop resistance lower than a preset threshold acoustic warning is provided.Test results exceeding the designated limits are marked with red color.

  • User Side TDRELEKTR NIKAIn case of a cable break or short circuit the first task is to identify the location of fault. First of all the operator has to know that the fault is inside the building of central office or it is somewhere else on the line. The purpose of the User Side TDR is to test the access line.

    Two modes are provided: Normal mode for the localization of shorts and brakes. Long time mode for the localization of loose contacts.

  • Spectrum AnalyserELEKTR NIKAThe purpose of the User Side Spectrum measurement is to get information about the disturbing voltages on the line.In that mode ETET 30 can detect the presence of ADSL, ADSL 2+ or VDSL modem at the users home when the DSLAM is disconnected from the subscribers line.

  • User Side Test CallELEKTR NIKAIn this mode the subscribers telephone set can be tested with his assistance.The operator should call and communicate with the subscriber. Loop TestAsk the subscriber to keep the line and wait. Start loop resistance and loop current measurements with the Loop Test key. Loudness TestSend test tone with the Send 800 Hz key. After a while ask the subscribers opinion about the loudness.Dial TestSometimes the subscribers complain that they are connected to another subscriber instead of the one they wanted to call. The purpose of that test is to identify the reason of the malfunction. Press the Dial Test key. Ask the subscriber to press the numbers on his key board after each other.

  • Exchange Side Tests of ETET 30ELEKTR NIKAETET 30 provides: The test of ringing, register and line feed circuits of exchange. The location of wiring problems inside the building of central office.

    Selectable Modes: DMM TDR Ringing Test Register TestFor details click on the corresponding keys.

  • Exchange Side DMM Measurement ELEKTR NIKA Voltage Measurements AC, DC voltages between wire A and GND AC, DC voltages between wire B and GND AC, DC voltages between the wires Loop Current Measurements When the loop is closed. Automatic Test Sequence Pressing the Auto key ETET 30 performs the previous measurements. Continuity Measurement In this mode ETET 30 performs loop resistance measurement. If the loop resistance lower than a preset threshold acoustic warning is provided.Test results exceeding the designated limits are marked with red color.

  • Exchange Side TDR ELEKTR NIKAIn case of a cable break or short circuit the first task is to identify the location of fault. First of all the operator has to know that the fault is inside the building of central office or it is somewhere else on the line. The purpose of Exchange Side TDR is to test the wiring inside the building of central office.

    Two modes are provided: Normal mode for the localization of shorts and brakes. Long time mode for the localization of loose contacts.

  • Ringing Test ELEKTR NIKAIn this mode the operator can dial up any phone number using a service line.

    Typical applications: The subscriber complains that the loudness of ringing is not enough. To check the proper operation of exchange the operator dials the users phone number and ETET 30 measures the ringing voltage.

    The operator would like to use ETET 30 as a normal phone.

  • Register Test ELEKTR NIKA

    Sometimes the subscribers complain that they are connected to another subscriber instead of the one they wanted to call. The purpose of that test is to identify the reason of the malfunction.

    In this mode ETET 30 sends a test call from the subscribers line to the service line and indicates the appearance of ringing voltage.

  • Modem DetectionELEKTR NIKAFunction:In that mode ETET 30 can detect the presence of ADSL, ADSL 2+ or VDSL modem at the users home when the DSLAM is disconnected from the subscribers line. Principle of operation:The modem detection is based on spectrum measurement. ETET 30 recognizes the hand shake signals rhythmically transmitted by the modem.

  • ETET 30 offers two test options: Synchronization Test providing information on the training process and the actual state of line. In this mode there isnt data transfer between the local and public network. Automatic Test providing detailed information on the quality of data transfer between the local and public network. The actual connection profile and the LAN parameters can be modified before starting the test.ADSL Modem TestsBy means of the Golden Modem of ETET 30 we can check the proper operation of DSLAM. For details click on the corresponding keys.ELEKTR NIKA

  • ADSL Synchronization Test The status indicator shows the actual state of synchronization:REDThe line is in Idle State (No synchrony)GREEN (blinking)The training is in progressGREEN (Continuous)The synchronization is completed

    Finishing the training process ETET 30 provides detailed line diagnosis.

    When the synchronization test mode is selected the Modem Status display appears and ETET 30 automatically starts the synchronization. The training process takes a while. During this time the actual modem status information is displayed. ELEKTR NIKA

  • Automatic ADSL Test When the automatic test mode is selected the Modem Status display appears and ETET 30 automatically starts the synchronization. The training process takes a while. During this time the actual modem status information is displayed. ELEKTR NIKAFor details click on the corresponding key. xDSL connection Indicator RED No synchrony GREEN (blinking) The training is in progress GREEN (Continuous) The synchronization is completed

    Link IP Status Indicator RED There is no data transfer YELLOW Trying to establish data transfer GREEN Successful data transfer

    ETET 30 provides: Ping & Trace test Detailed line diagnosis Browsing possibility

  • Editing of ADSL Profile ELEKTR NIKASupported ADSL ModesAs a default ETET 30 supports the synchronization in all ADSL modes but the operator can disable one ore more of them.Selectable connection types:In ADSL mode ETET 30 supports five connection types.

    ETET 30 supports the synchronization in all ADSL modes and connection types.

  • LAN Settings ELEKTR NIKAThe IP parameters of the modem and the controller PC can be modified here.

  • Ping & Trace Test ELEKTR NIKAThe ping tests can manage: the URL format IP address format

    The number of PING requests and the size of PING packets can be set.

    To call the Trace Test window click on the Trace key

  • Trace Test ELEKTR NIKAThe Trace Test can manage: the URL format IP address format

  • Line Diagnosis ELEKTR NIKAIn this mode ETET 30 provides detailed line diagnosis in graphic and numeric forms.

  • VDSL Modem Test ETET 30 offers two test options: Synchronization Test providing information on the training process and the actual state of line. In this mode there isnt data transfer between the local and public network. Automatic Test providing detailed information on the quality of data transfer between the local and public network. The actual connection profile and the LAN parameters can be modified before starting the test.By means of the Golden Modem of ETET 30 we can check the proper operation of DSLAM. For details click on the corresponding keys.ELEKTR NIKA

  • VDSL Synchronization Test The status indicator shows the actual state of synchronization:REDThe line is in Idle State (No synchrony)GREEN (blinking)The training is in progressGREEN (Continuous)The synchronization is completed

    Finishing the training process ETET 30 provides detailed line diagnosis.

    When the synchronization test mode is selected the Modem Status display appears and ETET 30 automatically starts the synchronization. The training process takes a while. During this time the actual modem status information is displayed. ELEKTR NIKA

  • Automatic VDSL Test When the automatic test mode is selected the Modem Status display appears and ETET 30 automatically starts the synchronization. The training process takes a while. During this time the actual modem status information is displayed. ELEKTR NIKAFor details click on the corresponding key. xDSL connection Indicator RED No synchrony GREEN (blinking) The training is in progress GREEN (Continuous) The synchronization is completed

    Link IP Status Indicator RED There is no data transfer YELLOW Trying to establish data transfer GREEN Successful data transfer

    ETET 30 provides: Ping & Trace test Detailed line diagnosis Browsing possibility

  • Editing of VDSL Profile ELEKTR NIKASupported ADSL ModesAs a default ETET 30 supports the synchronization in all VDSL modes but the operator can disable one ore more of them.Selectable connection types:In VDSL mode ETET 30 supports three connection types.

    ETET 30 supports the synchronization in all VDSL modes and connection types.

  • LAN Settings ELEKTR NIKAThe IP parameters of the modem and the controller PC can be modified here.

  • Ping &Trace Test ELEKTR NIKAThe ping tests can manage: the URL format IP address format

    The number of PING requests and the size of PING packets can be set.

    To call the Trace Test window click on the Trace key

  • Trace Test ELEKTR NIKAThe Trace Test can manage: the URL format IP address format

  • Line Diagnosis ELEKTR NIKAIn this mode ETET 30 provides detailed line diagnosis in graphic and numeric forms.